http://www.openzwave.com/device-database/0086:004A:0102
images/aeotec/zw074.png
https://products.z-wavealliance.org/products/1163/
The Aeotec by Aeon Labs MultiSensor Gen5 looks like a motion sensor and it acts like one too. But it’s also so much more. Installing this 1 piece of Z-Wave technology is the same as installing 4 pieces of Z-Wave technology. Your home control network will immediately understand motion, temperature, humidity and light readings wherever Multisensor installed. Those intelligent readings will equate to intelligence automation. And intelligent automation will give you the perfect, smart home.
ZW074-A
Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Z-Wave button that you can find in back of the product.
https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1170/Instructions - MultiSensor Gen5 MCert1.pdf
MultiSensor Gen5
Press and hold the Z-Wave button that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Z-Wave button that you can find in the back of the product.
Press and hold the Z-Wave button for 3 seconds will trigger sending the Wake up notification command. If press the Z-Wave button 3 times, the MultiSensor will wake up for 10 minutes.
U.S. / Canada / Mexico
Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1163/xml
Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1169/xml
Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1170/xml
https://products.z-wavealliance.org/products/1169/
ZW074-B
Australia / New Zealand
https://products.z-wavealliance.org/products/1170/
ZW074-C
CEPT (Europe)
Stay awake for 10 minutes after batteries are inserted
How long should the device associated to multi sensor keep state On before sending it Off command (if the value is bigger than 255, the value would be rounded to next integer in minutes)
Enable Motion Sensor
Which commands to send when PIR motion sensor triggered
OZW Ideal Value is Binary Sensor Report
Enable/disable the selective reporting only when measurements reach a certain threshold or percentage
set in the threshold settings. This is used to reduce network
traffic.
Threshold change in temperature to induce an automatic report.
Note:
1. When the unit is Celsius, threshold=Value.
2. When the unit is Fahrenheit, threshold=Value*1.8. The accuracy is 0.1.
3. The high byte is the part of integer, the low byte is the fractional part.
Threshold change in humidity to induce an automatic report.
Note:
The accuracy is 0.1.
The high byte is the part of integer, the low byte is the fractional part.
Threshold change in luminance to induce an automatic report.
Threshold change in battery level to induce an automatic report.
Note:
The accuracy is 0.1.
The high byte is the part of integer, the low byte is the fractional part.
Enable/disable to send the alarm report of low temperature(Less than 15 Degress C)
Which reports need to send automatically in timing intervals for group 1. Bitsets: 0 -> Battery report, 5 -> Temperature, 6 -> Humidity, 7 -> Luminosity
Which reports need to send automatically in timing intervals for group 2. Bitsets: 0 -> Battery report, 5 -> Temperature, 6 -> Humidity, 7 -> Luminosity
Which reports need to send automatically in timing intervals for group 3. Bitsets: 0 -> Battery report, 5 -> Temperature, 6 -> Humidity, 7 -> Luminosity
The interval of sending report group 1. 1 to 2678400 seconds
The interval of sending report group 2. 1 to 2678400 seconds
The interval of sending report group 3. 1 to 2678400 seconds
Enable/disable Lock Configuration
Reset to factory defaults.
false