http://www.openzwave.com/device-database/0086:0013:0003 images/aeotec/dsc19103.png https://products.z-wavealliance.org/products/774/ Micro Smart Energy Illuminator G2 U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand With so many new-generation, energy-saving lights now available for your home, dimming lights isn’t as straightforward as it used to be. There’s no one type of light any more. Aeotec’s plug-in Smart Energy Illuminator is, however, compatible with as many dimmable lights as possible. Our Smart Energy Illuminator has been designed to work out of the box with halogen lamp, sodium and tungsten lights. It’s also capable of being plugged in to other types of lights that work by reducing the amount of electricity being passed to their transformer. This includes select LED lights. DSC19103-ZWAU http://aeotec.com/z-wave-in-wall-switches Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/707/xml Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/766/xml Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/774/xml This is actually a double byte value. The LSB defines the total time the device needs to blink in seconds. The MSB defines the on/off interval of the blink in tenths of seconds. Current Overload Protection. Load will be closed when 3 the Current more than 2.7A and the time more than 2 minutes Enables automatic notifications to associated devices whenever there is a state change. Enable/disable Wattage threshold and percent. The minimum change in wattage for a report to be sent. Minimum change in percent of wattage to send a report. Set report types for groups 1, 2 and 3 to default. Reverts to 0 after set. Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. Value 1 (msb) Reserved Value 2 Reserved Value 3 Reserved Value 4 (lsb) bits 7-4 reserved bit 3 MRC (KWH) bit 2 MRC (watt) bit 1 MSRC (Current) bit 0 MRC (Voltage) The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(KWh) automatically. The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(wattage) automatically. The MSRC flag signals that Report Group 1 send(1) or don't send(0) Multilevel Sensor Report Command(wattage) automatically. Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. Value 1 (msb) Reserved Value 2 Reserved Value 3 Reserved Value 4 (lsb) bits 7-4 reserved bit 3 MRC (KWH) bit 2 MRC (watt) bit 1 MSRC (Current) bit 0 MRC (Voltage) The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(KWh) automatically. The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(wattage) automatically. The MSRC flag signals that Report Group 1 send(1) or don't send(0) Multilevel Sensor Report Command(wattage) automatically. Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. Value 1 (msb) Reserved Value 2 Reserved Value 3 Reserved Value 4 (lsb) bits 7-4 reserved bit 3 MRC (KWH) bit 2 MRC (watt) bit 1 MSRC (Current) bit 0 MRC (Voltage) The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(KWh) automatically. The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(wattage) automatically. The MSRC flag signals that Report Group 1 send(1) or don't send(0) Multilevel Sensor Report Command(wattage) automatically. Set time interval for sending reports for groups 1, 2 and 3 to default. Defines the time interval when the defined report for group 1 is sent. Defines the time interval when the defined report for group 2 is sent. Defines the time interval when the defined report for group 3 is sent. Turn external button mode Device tag. Reset to the default configuration.