http://www.openzwave.com/device-database/0086:0012:0003
images/aeotec/dsc18103.png
https://products.z-wavealliance.org/products/775/
U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand
Micro Smart Energy Switch G2
It has long been thought that a house becomes a home when we make it reflect who we are, when we personalise it, when we fill it with objects we treasure. And all of that remains true, but it no longer needs to be just the objects we put in our home that personalises it. Like the music that gently fills the background of your favourite restaurant, Aeotec’s Micro Switches create the perfect ambiance for your home, and then some. They also give you the perfect control and the perfect, intelligent automation.
Across three different Micro controllers, each one letting you perfect everything from your home’s lights to its appliances and to its motorised doors and curtains, you’ll find that the same magic has been built right into the tiny body of each switch.
DSC18103-ZWAU
http://aeotec.com/z-wave-in-wall-switches
Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/708/xml
Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/767/xml
Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/775/xml
Defines the contents of Multilevel Sensor Report after Multilevel Sensor Get received.
This is actually a double byte value. The LSB defines the total time the device needs to blink in seconds. The MSB defines the on/off interval of the blink in tenths of seconds.
Enables automatic notifications to associated devices whenever there is a state change.
Enable/disable Wattage threshold and percent.
The minimum change in wattage for a report to be sent.
Minimum change in percent of wattage to send a report.
Set report types for groups 1, 2 and 3 to default. Reverts to 0
after set.
Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts.
Value 1 (msb) Reserved
Value 2 Reserved
Value 3 Reserved
Value 4 (lsb) bits 7-4 reserved
bit 3 MRC(KWH)
bit 2 MRC(watt)
bit 1 MSRC
bit 0 reserved
The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(KWh) automatically.
The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(wattage) automatically.
The MSRC flag signals that Report Group 1 send(1) or don't send(0)
Multilevel Sensor Report Command(wattage) automatically.
Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts.
Value 1 (msb) Reserved
Value 2 Reserved
Value 3 Reserved
Value 4 (lsb) bits 7-4 reserved
bit 3 MRC(KWH)
bit 2 MRC(watt)
bit 1 MSRC
bit 0 reserved
The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(KWh) automatically.
The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(wattage) automatically.
The MSRC flag signals that Report Group 1 send(1) or don't send(0)
Multilevel Sensor Report Command(wattage) automatically.
Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts.
Value 1 (msb) Reserved
Value 2 Reserved
Value 3 Reserved
Value 4 (lsb) bits 7-4 reserved
bit 3 MRC(KWH)
bit 2 MRC(watt)
bit 1 MSRC
bit 0 reserved
The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(KWh) automatically.
The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(wattage) automatically.
The MSRC flag signals that Report Group 1 send(1) or don't send(0)
Multilevel Sensor Report Command(wattage) automatically.
Set time interval for sending reports for groups 1, 2 and 3 to default.
Defines the time interval when the defined report for group 1 is sent.
Defines the time interval when the defined report for group 2 is sent.
Defines the time interval when the defined report for group 3 is sent.
Device tag.
Reset to the default configuration.