diff --git a/.etckeeper b/.etckeeper index ece8553d..58e8534f 100755 --- a/.etckeeper +++ b/.etckeeper @@ -1,6 +1,14 @@ # Generated by etckeeper. Do not edit. +mkdir -p './NetworkManager/conf.d' +mkdir -p './NetworkManager/dispatcher.d/no-wait.d' +mkdir -p './NetworkManager/dispatcher.d/pre-down.d' +mkdir -p './NetworkManager/dispatcher.d/pre-up.d' +mkdir -p './NetworkManager/dnsmasq-shared.d' +mkdir -p './NetworkManager/dnsmasq.d' +mkdir -p './NetworkManager/system-connections' mkdir -p './X11/xkb' +mkdir -p './X11/xorg.conf.d' mkdir -p './apache2/mods-available' mkdir -p './apt/auth.conf.d' mkdir -p './apt/listchanges.conf.d' @@ -9,8 +17,10 @@ mkdir -p './apt/trusted.gpg.d' mkdir -p './avahi/services' mkdir -p './binfmt.d' mkdir -p './dbus-1/session.d' +mkdir -p './dconf/db' mkdir -p './dnsmasq.d' mkdir -p './gdb/gdbinit.d' +mkdir -p './glvnd/egl_vendor.d' mkdir -p './gss/mech.d' mkdir -p './initramfs-tools/conf.d' mkdir -p './initramfs-tools/hooks' @@ -41,6 +51,9 @@ mkdir -p './polkit-1/localauthority/30-site.d' mkdir -p './polkit-1/localauthority/50-local.d' mkdir -p './polkit-1/localauthority/90-mandatory.d' mkdir -p './postgresql/11/main/conf.d' +mkdir -p './ppp/ip-pre-up.d' +mkdir -p './ppp/ipv6-down.d' +mkdir -p './ppp/ipv6-up.d' mkdir -p './puppetlabs' mkdir -p './resolvconf/update-libc.d' mkdir -p './security/limits.d' @@ -50,6 +63,9 @@ mkdir -p './ssh/sshd_config.d' mkdir -p './triggerhappy/triggers.d' mkdir -p './udev/hwdb.d' mkdir -p './usb_modeswitch.d' +mkdir -p './vulkan/explicit_layer.d' +mkdir -p './vulkan/icd.d' +mkdir -p './vulkan/implicit_layer.d' maybe chmod 0755 '.' maybe chmod 0700 '.etckeeper' maybe chmod 0644 '.fstab' @@ -75,8 +91,20 @@ maybe chmod 0644 'ImageMagick-6/type-urw-base35.xml' maybe chmod 0644 'ImageMagick-6/type-windows.xml' maybe chmod 0644 'ImageMagick-6/type.xml' maybe chmod 0755 'NetworkManager' +maybe chmod 0644 'NetworkManager/NetworkManager.conf' +maybe chmod 0755 'NetworkManager/conf.d' maybe chmod 0755 'NetworkManager/dispatcher.d' +maybe chmod 0755 'NetworkManager/dispatcher.d/01-ifupdown' +maybe chmod 0755 'NetworkManager/dispatcher.d/no-wait.d' maybe chmod 0755 'NetworkManager/dispatcher.d/ntp' +maybe chmod 0755 'NetworkManager/dispatcher.d/pre-down.d' +maybe chmod 0755 'NetworkManager/dispatcher.d/pre-up.d' +maybe chmod 0755 'NetworkManager/dnsmasq-shared.d' +maybe chmod 0755 'NetworkManager/dnsmasq.d' +maybe chmod 0755 'NetworkManager/system-connections' +maybe chmod 0755 'PackageKit' +maybe chmod 0644 'PackageKit/PackageKit.conf' +maybe chmod 0644 'PackageKit/Vendor.conf' maybe chmod 0755 'X11' maybe chmod 0755 'X11/Xreset' maybe chmod 0755 'X11/Xreset.d' @@ -92,11 +120,13 @@ maybe chmod 0644 'X11/Xsession.d/35x11-common_xhost-local' maybe chmod 0644 'X11/Xsession.d/40x11-common_xsessionrc' maybe chmod 0644 'X11/Xsession.d/50x11-common_determine-startup' maybe chmod 0644 'X11/Xsession.d/90gpg-agent' +maybe chmod 0644 'X11/Xsession.d/90qt-a11y' maybe chmod 0644 'X11/Xsession.d/90x11-common_ssh-agent' maybe chmod 0644 'X11/Xsession.d/99x11-common_start' maybe chmod 0644 'X11/Xsession.options' maybe chmod 0644 'X11/rgb.txt' maybe chmod 0755 'X11/xkb' +maybe chmod 0755 'X11/xorg.conf.d' maybe chmod 0644 'adduser.conf' maybe chmod 0644 'aliases' maybe chmod 0755 'alternatives' @@ -126,9 +156,11 @@ maybe chmod 0644 'apt/apt.conf.d/05etckeeper' maybe chmod 0644 'apt/apt.conf.d/15update-stamp' maybe chmod 0644 'apt/apt.conf.d/20auto-upgrades' maybe chmod 0644 'apt/apt.conf.d/20listchanges' +maybe chmod 0644 'apt/apt.conf.d/20packagekit' maybe chmod 0644 'apt/apt.conf.d/50raspi' maybe chmod 0644 'apt/apt.conf.d/50unattended-upgrades' maybe chmod 0644 'apt/apt.conf.d/70debconf' +maybe chmod 0644 'apt/apt.conf.d/99nymea' maybe chmod 0755 'apt/auth.conf.d' maybe chmod 0644 'apt/listchanges.conf' maybe chmod 0755 'apt/listchanges.conf.d' @@ -165,6 +197,12 @@ maybe chmod 0755 'ca-certificates/update.d' maybe chmod 0755 'ca-certificates/update.d/jks-keystore' maybe chmod 0755 'calendar' maybe chmod 0644 'calendar/default' +maybe chgrp 'dip' 'chatscripts' +maybe chmod 2750 'chatscripts' +maybe chmod 0644 'chatscripts/gprs' +maybe chmod 0644 'chatscripts/pap' +maybe chgrp 'dip' 'chatscripts/provider' +maybe chmod 0640 'chatscripts/provider' maybe chmod 0770 'check_mk' maybe chmod 0640 'check_mk/cmk-update-agent.cfg' maybe chmod 0640 'check_mk/docker.cfg' @@ -242,7 +280,13 @@ maybe chmod 0755 'dbus-1/session.d' maybe chmod 0755 'dbus-1/system.d' maybe chmod 0644 'dbus-1/system.d/avahi-dbus.conf' maybe chmod 0644 'dbus-1/system.d/bluetooth.conf' +maybe chmod 0644 'dbus-1/system.d/dnsmasq.conf' +maybe chmod 0644 'dbus-1/system.d/io.guh.nymead.conf' +maybe chmod 0644 'dbus-1/system.d/org.freedesktop.ModemManager1.conf' +maybe chmod 0644 'dbus-1/system.d/org.freedesktop.PackageKit.conf' maybe chmod 0644 'dbus-1/system.d/wpa_supplicant.conf' +maybe chmod 0755 'dconf' +maybe chmod 0755 'dconf/db' maybe chmod 0644 'debconf.conf' maybe chmod 0644 'debian_version' maybe chmod 0755 'default' @@ -329,6 +373,8 @@ maybe chmod 0644 'dpkg/shlibs.override' maybe chmod 0644 'e2scrub.conf' maybe chmod 0644 'email-addresses' maybe chmod 0644 'environment' +maybe chmod 0755 'environment.d' +maybe chmod 0644 'environment.d/90qt-a11y.conf' maybe chmod 0755 'etckeeper' maybe chmod 0755 'etckeeper/commit.d' maybe chmod 0755 'etckeeper/commit.d/10vcs-test' @@ -473,6 +519,8 @@ maybe chmod 0770 'gitea' maybe chown 'git' 'gitea/app.ini' maybe chgrp 'git' 'gitea/app.ini' maybe chmod 0644 'gitea/app.ini' +maybe chmod 0755 'glvnd' +maybe chmod 0755 'glvnd/egl_vendor.d' maybe chmod 0755 'groff' maybe chmod 0644 'groff/man.local' maybe chmod 0644 'groff/mdoc.local' @@ -485,6 +533,8 @@ maybe chgrp 'shadow' 'gshadow-' maybe chmod 0640 'gshadow-' maybe chmod 0755 'gss' maybe chmod 0755 'gss/mech.d' +maybe chmod 0755 'gtk-3.0' +maybe chmod 0644 'gtk-3.0/im-multipress.conf' maybe chmod 0644 'host.conf' maybe chmod 0644 'hostname' maybe chmod 0644 'hosts' @@ -842,8 +892,10 @@ maybe chmod 0644 'logrotate.d/exim4-paniclog' maybe chmod 0644 'logrotate.d/mosquitto' maybe chmod 0644 'logrotate.d/nginx' maybe chmod 0644 'logrotate.d/nodered' +maybe chmod 0644 'logrotate.d/nymead' maybe chmod 0644 'logrotate.d/php7.3-fpm' maybe chmod 0644 'logrotate.d/postgresql-common' +maybe chmod 0644 'logrotate.d/ppp' maybe chmod 0644 'logrotate.d/rsyslog' maybe chmod 0644 'logrotate.d/syslog' maybe chmod 0644 'logrotate.d/unattended-upgrades' @@ -970,6 +1022,1638 @@ maybe chmod 0644 'nginx/uwsgi_params' maybe chmod 0644 'nginx/win-utf' maybe chmod 0644 'nsswitch.conf' maybe chmod 0644 'ntp.conf' +maybe chmod 0755 'nymea' +maybe chmod 0644 'nymea/nymead.conf' +maybe chmod 0644 'nymea/user-db.sqlite' +maybe chmod 0755 'openzwave' +maybe chmod 0755 'openzwave/2gig' +maybe chmod 0644 'openzwave/2gig/ct100.xml' +maybe chmod 0644 'openzwave/2gig/ct101.xml' +maybe chmod 0644 'openzwave/2gig/ct30.xml' +maybe chmod 0644 'openzwave/2gig/ct32.xml' +maybe chmod 0644 'openzwave/2gig/ct50e.xml' +maybe chmod 0644 'openzwave/2gig/ct80.xml' +maybe chmod 0755 'openzwave/BeNext' +maybe chmod 0644 'openzwave/BeNext/1poleswitch.xml' +maybe chmod 0644 'openzwave/BeNext/2poleswitch.xml' +maybe chmod 0644 'openzwave/BeNext/AlarmSound.xml' +maybe chmod 0644 'openzwave/BeNext/BuiltinDimmer.xml' +maybe chmod 0644 'openzwave/BeNext/DoorSensor.xml' +maybe chmod 0644 'openzwave/BeNext/EnergySwitch.xml' +maybe chmod 0644 'openzwave/BeNext/HeatingControl.xml' +maybe chmod 0644 'openzwave/BeNext/Molite.xml' +maybe chmod 0644 'openzwave/BeNext/P1dongle.xml' +maybe chmod 0644 'openzwave/BeNext/PanicButton.xml' +maybe chmod 0644 'openzwave/BeNext/PanicWatch.xml' +maybe chmod 0644 'openzwave/BeNext/PluginDimmer.xml' +maybe chmod 0644 'openzwave/BeNext/SceneController.xml' +maybe chmod 0644 'openzwave/BeNext/TagReader.xml' +maybe chmod 0644 'openzwave/BeNext/TagReader500.xml' +maybe chmod 0644 'openzwave/BeNext/mydisplay.xml' +maybe chmod 0644 'openzwave/BeNext/mygate.xml' +maybe chmod 0644 'openzwave/Localization.xml' +maybe chmod 0644 'openzwave/Localization.xsd' +maybe chmod 0644 'openzwave/NotificationCCTypes.xml' +maybe chmod 0644 'openzwave/NotificationCCTypes.xsd' +maybe chmod 0644 'openzwave/SensorMultiLevelCCTypes.xml' +maybe chmod 0644 'openzwave/SensorMultiLevelCCTypes.xsd' +maybe chmod 0755 'openzwave/abus' +maybe chmod 0644 'openzwave/abus/SHRM10000.xml' +maybe chmod 0755 'openzwave/act' +maybe chmod 0644 'openzwave/act/lfm20.xml' +maybe chmod 0644 'openzwave/act/zdm230.xml' +maybe chmod 0644 'openzwave/act/zdp100.xml' +maybe chmod 0644 'openzwave/act/zdw103.xml' +maybe chmod 0644 'openzwave/act/zdw232.xml' +maybe chmod 0644 'openzwave/act/zir010.xml' +maybe chmod 0644 'openzwave/act/zrm230.xml' +maybe chmod 0644 'openzwave/act/zrp100.xml' +maybe chmod 0644 'openzwave/act/zrp110.xml' +maybe chmod 0644 'openzwave/act/zrw103.xml' +maybe chmod 0644 'openzwave/act/zrw230.xml' +maybe chmod 0755 'openzwave/aeotec' +maybe chmod 0644 'openzwave/aeotec/dsa03202.xml' +maybe chmod 0644 'openzwave/aeotec/dsa22.xml' +maybe chmod 0644 'openzwave/aeotec/dsa38.xml' +maybe chmod 0644 'openzwave/aeotec/dsb04100.xml' +maybe chmod 0644 'openzwave/aeotec/dsb05.xml' +maybe chmod 0644 'openzwave/aeotec/dsb09104.xml' +maybe chmod 0644 'openzwave/aeotec/dsb28-zweu.xml' +maybe chmod 0644 'openzwave/aeotec/dsb28.xml' +maybe chmod 0644 'openzwave/aeotec/dsb29.xml' +maybe chmod 0644 'openzwave/aeotec/dsb45.xml' +maybe chmod 0644 'openzwave/aeotec/dsb54.xml' +maybe chmod 0644 'openzwave/aeotec/dsc06106.xml' +maybe chmod 0644 'openzwave/aeotec/dsc08101.xml' +maybe chmod 0644 'openzwave/aeotec/dsc10.xml' +maybe chmod 0644 'openzwave/aeotec/dsc11.xml' +maybe chmod 0644 'openzwave/aeotec/dsc12104.xml' +maybe chmod 0644 'openzwave/aeotec/dsc13104.xml' +maybe chmod 0644 'openzwave/aeotec/dsc14104.xml' +maybe chmod 0644 'openzwave/aeotec/dsc18103.xml' +maybe chmod 0644 'openzwave/aeotec/dsc19103.xml' +maybe chmod 0644 'openzwave/aeotec/dsc24.xml' +maybe chmod 0644 'openzwave/aeotec/dsc26103.xml' +maybe chmod 0644 'openzwave/aeotec/dsc27103.xml' +maybe chmod 0644 'openzwave/aeotec/dsc35103.xml' +maybe chmod 0644 'openzwave/aeotec/dsd37.xml' +maybe chmod 0644 'openzwave/aeotec/zw056.xml' +maybe chmod 0644 'openzwave/aeotec/zw062.xml' +maybe chmod 0644 'openzwave/aeotec/zw074.xml' +maybe chmod 0644 'openzwave/aeotec/zw075.xml' +maybe chmod 0644 'openzwave/aeotec/zw078.xml' +maybe chmod 0644 'openzwave/aeotec/zw080.xml' +maybe chmod 0644 'openzwave/aeotec/zw088.xml' +maybe chmod 0644 'openzwave/aeotec/zw089.xml' +maybe chmod 0644 'openzwave/aeotec/zw090.xml' +maybe chmod 0644 'openzwave/aeotec/zw095.xml' +maybe chmod 0644 'openzwave/aeotec/zw096.xml' +maybe chmod 0644 'openzwave/aeotec/zw097.xml' +maybe chmod 0644 'openzwave/aeotec/zw098.xml' +maybe chmod 0644 'openzwave/aeotec/zw099.xml' +maybe chmod 0644 'openzwave/aeotec/zw100.xml' +maybe chmod 0644 'openzwave/aeotec/zw111.xml' +maybe chmod 0644 'openzwave/aeotec/zw112.xml' +maybe chmod 0644 'openzwave/aeotec/zw116.xml' +maybe chmod 0644 'openzwave/aeotec/zw117.xml' +maybe chmod 0644 'openzwave/aeotec/zw120.xml' +maybe chmod 0644 'openzwave/aeotec/zw121.xml' +maybe chmod 0644 'openzwave/aeotec/zw122.xml' +maybe chmod 0644 'openzwave/aeotec/zw129.xml' +maybe chmod 0644 'openzwave/aeotec/zw130.xml' +maybe chmod 0644 'openzwave/aeotec/zw132.xml' +maybe chmod 0644 'openzwave/aeotec/zw139.xml' +maybe chmod 0644 'openzwave/aeotec/zw140.xml' +maybe chmod 0644 'openzwave/aeotec/zw141.xml' +maybe chmod 0644 'openzwave/aeotec/zw162.xml' +maybe chmod 0644 'openzwave/aeotec/zw164.xml' +maybe chmod 0644 'openzwave/aeotec/zw175.xml' +maybe chmod 0644 'openzwave/aeotec/zw187.xml' +maybe chmod 0644 'openzwave/aeotec/zw189.xml' +maybe chmod 0644 'openzwave/aeotec/zwa001.xml' +maybe chmod 0644 'openzwave/aeotec/zwa002.xml' +maybe chmod 0644 'openzwave/aeotec/zwa003.xml' +maybe chmod 0644 'openzwave/aeotec/zwa004.xml' +maybe chmod 0644 'openzwave/aeotec/zwa005.xml' +maybe chmod 0644 'openzwave/aeotec/zwa006.xml' +maybe chmod 0644 'openzwave/aeotec/zwa008.xml' +maybe chmod 0644 'openzwave/aeotec/zwa009.xml' +maybe chmod 0644 'openzwave/aeotec/zwa012.xml' +maybe chmod 0644 'openzwave/aeotec/zwa019.xml' +maybe chmod 0644 'openzwave/aeotec/zwa021.xml' +maybe chmod 0755 'openzwave/airlinemechanical' +maybe chmod 0644 'openzwave/airlinemechanical/zds-ud10.xml' +maybe chmod 0755 'openzwave/alfred' +maybe chmod 0644 'openzwave/alfred/DB2.xml' +maybe chmod 0755 'openzwave/assa_abloy' +maybe chmod 0644 'openzwave/assa_abloy/ConexisL1.xml' +maybe chmod 0644 'openzwave/assa_abloy/KeyfreeConnected-plus.xml' +maybe chmod 0644 'openzwave/assa_abloy/KeyfreeConnected.xml' +maybe chmod 0644 'openzwave/assa_abloy/PushButtonDeadbolt.xml' +maybe chmod 0644 'openzwave/assa_abloy/PushButtonLever.xml' +maybe chmod 0644 'openzwave/assa_abloy/TouchDeadbolt.xml' +maybe chmod 0644 'openzwave/assa_abloy/TouchLever.xml' +maybe chmod 0644 'openzwave/assa_abloy/nexTouch.xml' +maybe chmod 0644 'openzwave/assa_abloy/yrd1x0.xml' +maybe chmod 0755 'openzwave/august' +maybe chmod 0644 'openzwave/august/asl-03.xml' +maybe chmod 0755 'openzwave/buffalo' +maybe chmod 0644 'openzwave/buffalo/hw-100v15a-zw.xml' +maybe chmod 0755 'openzwave/building36' +maybe chmod 0644 'openzwave/building36/b36-t10.xml' +maybe chmod 0755 'openzwave/comfort' +maybe chmod 0644 'openzwave/comfort/ucm.xml' +maybe chmod 0644 'openzwave/config-template.xml' +maybe chmod 0755 'openzwave/connecthome' +maybe chmod 0644 'openzwave/connecthome/ch-201.xml' +maybe chmod 0755 'openzwave/cooper' +maybe chmod 0644 'openzwave/cooper/RF9501.xml' +maybe chmod 0644 'openzwave/cooper/RF9505-T.xml' +maybe chmod 0644 'openzwave/cooper/RF9505-T.xml.zip' +maybe chmod 0644 'openzwave/cooper/RF9517.xml' +maybe chmod 0644 'openzwave/cooper/RF9540-N.xml' +maybe chmod 0644 'openzwave/cooper/RF9542-Z.xml' +maybe chmod 0644 'openzwave/cooper/RFWC5.xml' +maybe chmod 0644 'openzwave/cooper/rf9534.xml' +maybe chmod 0755 'openzwave/danfoss' +maybe chmod 0644 'openzwave/danfoss/living.xml' +maybe chmod 0644 'openzwave/danfoss/rsroom.xml' +maybe chmod 0644 'openzwave/danfoss/z.xml' +maybe chmod 0644 'openzwave/device_classes.xml' +maybe chmod 0644 'openzwave/device_classes.xsd' +maybe chmod 0644 'openzwave/device_configuration.xsd' +maybe chmod 0755 'openzwave/devolo' +maybe chmod 0644 'openzwave/devolo/connectz.xml' +maybe chmod 0644 'openzwave/devolo/mt02648.xml' +maybe chmod 0644 'openzwave/devolo/mt02755.xml' +maybe chmod 0644 'openzwave/devolo/mt02758.xml' +maybe chmod 0644 'openzwave/devolo/mt02792.xml' +maybe chmod 0644 'openzwave/devolo/mt2646.xml' +maybe chmod 0644 'openzwave/devolo/mt2647.xml' +maybe chmod 0644 'openzwave/devolo/mt2651.xml' +maybe chmod 0644 'openzwave/devolo/mt2652.xml' +maybe chmod 0644 'openzwave/devolo/mt2653.xml' +maybe chmod 0644 'openzwave/devolo/mt2756.xml' +maybe chmod 0644 'openzwave/devolo/mt2759.xml' +maybe chmod 0644 'openzwave/devolo/mt2760.xml' +maybe chmod 0644 'openzwave/devolo/mt2761.xml' +maybe chmod 0644 'openzwave/devolo/rs014G0159.xml' +maybe chmod 0755 'openzwave/diehlcontrols' +maybe chmod 0644 'openzwave/diehlcontrols/766366.xml' +maybe chmod 0755 'openzwave/dlink' +maybe chmod 0644 'openzwave/dlink/dch-z110.xml' +maybe chmod 0644 'openzwave/dlink/dch-z120.xml' +maybe chmod 0644 'openzwave/dlink/dch-z210.xml' +maybe chmod 0644 'openzwave/dlink/dch-z510.xml' +maybe chmod 0755 'openzwave/dome' +maybe chmod 0644 'openzwave/dome/0002.xml' +maybe chmod 0644 'openzwave/dome/0083.xml' +maybe chmod 0644 'openzwave/dome/0085.xml' +maybe chmod 0644 'openzwave/dome/0086.xml' +maybe chmod 0644 'openzwave/dome/0087.xml' +maybe chmod 0644 'openzwave/dome/0088.xml' +maybe chmod 0644 'openzwave/dome/0101.xml' +maybe chmod 0644 'openzwave/dome/0201.xml' +maybe chmod 0644 'openzwave/dome/dmex1.xml' +maybe chmod 0755 'openzwave/domitech' +maybe chmod 0644 'openzwave/domitech/zb22uk.xml' +maybe chmod 0644 'openzwave/domitech/ze27eu.xml' +maybe chmod 0755 'openzwave/domux' +maybe chmod 0644 'openzwave/domux/DX1CA-Z.xml' +maybe chmod 0644 'openzwave/domux/DX1CG-Z.xml' +maybe chmod 0644 'openzwave/domux/DX1DS-Z.xml' +maybe chmod 0644 'openzwave/domux/DX1HT-Z.xml' +maybe chmod 0644 'openzwave/domux/DX1MS-Z.xml' +maybe chmod 0644 'openzwave/domux/DX1SA-Z.xml' +maybe chmod 0644 'openzwave/domux/DX1WL-Z.xml' +maybe chmod 0644 'openzwave/domux/DX2SK-Z.xml' +maybe chmod 0755 'openzwave/dragontech' +maybe chmod 0644 'openzwave/dragontech/wd-100.xml' +maybe chmod 0755 'openzwave/duco' +maybe chmod 0644 'openzwave/duco/DucoBox.xml' +maybe chmod 0644 'openzwave/duco/Ducotronic_CO-RH_sensor.xml' +maybe chmod 0755 'openzwave/duwi' +maybe chmod 0644 'openzwave/duwi/05458.xml' +maybe chmod 0644 'openzwave/duwi/ZWES1000.xml' +maybe chmod 0644 'openzwave/duwi/ZWESJ300.xml' +maybe chmod 0644 'openzwave/duwi/zw-edan-300.xml' +maybe chmod 0644 'openzwave/duwi/zw-zdan-300.xml' +maybe chmod 0644 'openzwave/duwi/zwfb.xml' +maybe chmod 0644 'openzwave/duwi/zwws.xml' +maybe chmod 0755 'openzwave/ecodim' +maybe chmod 0644 'openzwave/ecodim/0.7.xml' +maybe chmod 0755 'openzwave/ecolink' +maybe chmod 0644 'openzwave/ecolink/doorwindow.xml' +maybe chmod 0644 'openzwave/ecolink/firefighter.xml' +maybe chmod 0644 'openzwave/ecolink/floodfreeze.xml' +maybe chmod 0644 'openzwave/ecolink/motion.xml' +maybe chmod 0644 'openzwave/ecolink/sensor.xml' +maybe chmod 0644 'openzwave/ecolink/tiltsensor.xml' +maybe chmod 0755 'openzwave/econet' +maybe chmod 0644 'openzwave/econet/ezw1204.xml' +maybe chmod 0755 'openzwave/electronicsolutions' +maybe chmod 0644 'openzwave/electronicsolutions/dbmz.xml' +maybe chmod 0755 'openzwave/enblink' +maybe chmod 0644 'openzwave/enblink/ss201-us-w_1308.xml' +maybe chmod 0755 'openzwave/enerwave' +maybe chmod 0644 'openzwave/enerwave/zw15rmplus.xml' +maybe chmod 0644 'openzwave/enerwave/zw15s.xml' +maybe chmod 0644 'openzwave/enerwave/zw20r.xml' +maybe chmod 0644 'openzwave/enerwave/zw20rm.xml' +maybe chmod 0644 'openzwave/enerwave/zw500d.xml' +maybe chmod 0644 'openzwave/enerwave/zwn-bpc.xml' +maybe chmod 0644 'openzwave/enerwave/zwn-sc7.xml' +maybe chmod 0644 'openzwave/enerwave/zwnrsm1plus.xml' +maybe chmod 0644 'openzwave/enerwave/zwnrsm2plus.xml' +maybe chmod 0755 'openzwave/eurotronic' +maybe chmod 0644 'openzwave/eurotronic/eur_airquality.xml' +maybe chmod 0644 'openzwave/eurotronic/eur_cometz.xml' +maybe chmod 0644 'openzwave/eurotronic/eur_spiritz.xml' +maybe chmod 0644 'openzwave/eurotronic/eur_stellaz.xml' +maybe chmod 0644 'openzwave/eurotronic/eur_temphumin.xml' +maybe chmod 0755 'openzwave/everspring' +maybe chmod 0644 'openzwave/everspring/ad146.xml' +maybe chmod 0644 'openzwave/everspring/ad147.xml' +maybe chmod 0644 'openzwave/everspring/an145.xml' +maybe chmod 0644 'openzwave/everspring/an157.xml' +maybe chmod 0644 'openzwave/everspring/an158.xml' +maybe chmod 0644 'openzwave/everspring/an163.xml' +maybe chmod 0644 'openzwave/everspring/an179.xml' +maybe chmod 0644 'openzwave/everspring/an180.xml' +maybe chmod 0644 'openzwave/everspring/an181.xml' +maybe chmod 0644 'openzwave/everspring/hac01.xml' +maybe chmod 0644 'openzwave/everspring/han01.xml' +maybe chmod 0644 'openzwave/everspring/han02-1.xml' +maybe chmod 0644 'openzwave/everspring/hsp02.xml' +maybe chmod 0644 'openzwave/everspring/lptdm1u.xml' +maybe chmod 0644 'openzwave/everspring/se812.xml' +maybe chmod 0644 'openzwave/everspring/sf812.xml' +maybe chmod 0644 'openzwave/everspring/sm103.xml' +maybe chmod 0644 'openzwave/everspring/sp103.xml' +maybe chmod 0644 'openzwave/everspring/sp814.xml' +maybe chmod 0644 'openzwave/everspring/sp815.xml' +maybe chmod 0644 'openzwave/everspring/sp816.xml' +maybe chmod 0644 'openzwave/everspring/st812.xml' +maybe chmod 0644 'openzwave/everspring/st814.xml' +maybe chmod 0644 'openzwave/everspring/st815.xml' +maybe chmod 0644 'openzwave/everspring/tse03.xml' +maybe chmod 0755 'openzwave/everspringct' +maybe chmod 0644 'openzwave/everspringct/hsm02.xml' +maybe chmod 0755 'openzwave/evolve' +maybe chmod 0644 'openzwave/evolve/lfm-20.xml' +maybe chmod 0644 'openzwave/evolve/lrm-as.xml' +maybe chmod 0644 'openzwave/evolve/lsm-15.xml' +maybe chmod 0644 'openzwave/evolve/ltm-5.xml' +maybe chmod 0755 'openzwave/fakro' +maybe chmod 0644 'openzwave/fakro/arz.xml' +maybe chmod 0644 'openzwave/fakro/zwp10.xml' +maybe chmod 0644 'openzwave/fakro/zwrs.xml' +maybe chmod 0644 'openzwave/fakro/zws12.xml' +maybe chmod 0644 'openzwave/fakro/zws230.xml' +maybe chmod 0755 'openzwave/fibaro' +maybe chmod 0644 'openzwave/fibaro/fgbs001.xml' +maybe chmod 0644 'openzwave/fibaro/fgbs222.xml' +maybe chmod 0644 'openzwave/fibaro/fgcd001.xml' +maybe chmod 0644 'openzwave/fibaro/fgd211.xml' +maybe chmod 0644 'openzwave/fibaro/fgd212.xml' +maybe chmod 0644 'openzwave/fibaro/fgdw2.xml' +maybe chmod 0644 'openzwave/fibaro/fgfs101.xml' +maybe chmod 0644 'openzwave/fibaro/fgfs101zw5.xml' +maybe chmod 0644 'openzwave/fibaro/fggc001.xml' +maybe chmod 0644 'openzwave/fibaro/fgk001.xml' +maybe chmod 0644 'openzwave/fibaro/fgk10x.xml' +maybe chmod 0644 'openzwave/fibaro/fgkf601.xml' +maybe chmod 0644 'openzwave/fibaro/fgms.xml' +maybe chmod 0644 'openzwave/fibaro/fgmszw5.xml' +maybe chmod 0644 'openzwave/fibaro/fgpb101.xml' +maybe chmod 0644 'openzwave/fibaro/fgr221.xml' +maybe chmod 0644 'openzwave/fibaro/fgr223.xml' +maybe chmod 0644 'openzwave/fibaro/fgrgbw442.xml' +maybe chmod 0644 'openzwave/fibaro/fgrgbwm441.xml' +maybe chmod 0644 'openzwave/fibaro/fgrm222.xml' +maybe chmod 0644 'openzwave/fibaro/fgs211.xml' +maybe chmod 0644 'openzwave/fibaro/fgs212.xml' +maybe chmod 0644 'openzwave/fibaro/fgs213.xml' +maybe chmod 0644 'openzwave/fibaro/fgs221.xml' +maybe chmod 0644 'openzwave/fibaro/fgs222.xml' +maybe chmod 0644 'openzwave/fibaro/fgs223.xml' +maybe chmod 0644 'openzwave/fibaro/fgs224.xml' +maybe chmod 0644 'openzwave/fibaro/fgsd002.xml' +maybe chmod 0644 'openzwave/fibaro/fgss101.xml' +maybe chmod 0644 'openzwave/fibaro/fgt001.xml' +maybe chmod 0644 'openzwave/fibaro/fgwd111.xml' +maybe chmod 0644 'openzwave/fibaro/fgwds221.xml' +maybe chmod 0644 'openzwave/fibaro/fgwoe.xml' +maybe chmod 0644 'openzwave/fibaro/fgwpe.xml' +maybe chmod 0644 'openzwave/fibaro/fgwpfzw5.xml' +maybe chmod 0644 'openzwave/fibaro/fgwpg111.xml' +maybe chmod 0644 'openzwave/fibaro/fgwr111.xml' +maybe chmod 0755 'openzwave/firstalert' +maybe chmod 0644 'openzwave/firstalert/zcombo-g.xml' +maybe chmod 0644 'openzwave/firstalert/zcombo.xml' +maybe chmod 0644 'openzwave/firstalert/zsmoke.xml' +maybe chmod 0755 'openzwave/followgood' +maybe chmod 0644 'openzwave/followgood/swz-1002.xml' +maybe chmod 0755 'openzwave/forest' +maybe chmod 0644 'openzwave/forest/fs2z5232000002.xml' +maybe chmod 0755 'openzwave/fortrezz' +maybe chmod 0644 'openzwave/fortrezz/fmi.xml' +maybe chmod 0755 'openzwave/fortrezz/fts05p.xml' +maybe chmod 0644 'openzwave/fortrezz/gdc1_fortrezz_1501.xml' +maybe chmod 0644 'openzwave/fortrezz/mimo2plus.xml' +maybe chmod 0644 'openzwave/fortrezz/mimolite.xml' +maybe chmod 0644 'openzwave/fortrezz/ssa2.xml' +maybe chmod 0644 'openzwave/fortrezz/ssa3.xml' +maybe chmod 0644 'openzwave/fortrezz/wv01.xml' +maybe chmod 0644 'openzwave/fortrezz/wwa-01aa.xml' +maybe chmod 0644 'openzwave/fortrezz/wwa02.xml' +maybe chmod 0755 'openzwave/frostdale' +maybe chmod 0644 'openzwave/frostdale/fdn2311.xml' +maybe chmod 0644 'openzwave/frostdale/fdn2nxx.xml' +maybe chmod 0755 'openzwave/ge' +maybe chmod 0644 'openzwave/ge/12719-plugin-switch.xml' +maybe chmod 0644 'openzwave/ge/12720.xml' +maybe chmod 0644 'openzwave/ge/12724-dimmer.xml' +maybe chmod 0644 'openzwave/ge/12727.xml' +maybe chmod 0644 'openzwave/ge/14280-plugin-dimmer.xml' +maybe chmod 0644 'openzwave/ge/14282-plugin-switch.xml' +maybe chmod 0644 'openzwave/ge/14284.xml' +maybe chmod 0644 'openzwave/ge/14285.xml' +maybe chmod 0644 'openzwave/ge/14288-outlet.xml' +maybe chmod 0644 'openzwave/ge/14291-switch.xml' +maybe chmod 0644 'openzwave/ge/14292-toggle-switch.xml' +maybe chmod 0644 'openzwave/ge/14294-dimmer.xml' +maybe chmod 0644 'openzwave/ge/14295-dimmer-toggle.xml' +maybe chmod 0644 'openzwave/ge/14298.xml' +maybe chmod 0644 'openzwave/ge/26931-motion-switch.xml' +maybe chmod 0644 'openzwave/ge/26932-motion-dimmer.xml' +maybe chmod 0644 'openzwave/ge/26933-motion-dimmer.xml' +maybe chmod 0644 'openzwave/ge/28167-plugin-dimmer.xml' +maybe chmod 0644 'openzwave/ge/28169-plugin-switch.xml' +maybe chmod 0644 'openzwave/ge/45604.xml' +maybe chmod 0644 'openzwave/ge/46201-switch.xml' +maybe chmod 0644 'openzwave/ge/46202-switch.xml' +maybe chmod 0644 'openzwave/ge/46203-dimmer.xml' +maybe chmod 0644 'openzwave/ge/46204-dimmer-toggle.xml' +maybe chmod 0644 'openzwave/ge/dimmer.xml' +maybe chmod 0644 'openzwave/ge/dimmer_module.xml' +maybe chmod 0644 'openzwave/ge/hinge-pin.xml' +maybe chmod 0644 'openzwave/ge/receptacle.xml' +maybe chmod 0644 'openzwave/ge/relay.xml' +maybe chmod 0644 'openzwave/ge/ze26i.xml' +maybe chmod 0644 'openzwave/ge/zw4001-switch.xml' +maybe chmod 0644 'openzwave/ge/zw6302.xml' +maybe chmod 0755 'openzwave/gocontrol' +maybe chmod 0644 'openzwave/gocontrol/GC-TBZ48L.xml' +maybe chmod 0755 'openzwave/goodway' +maybe chmod 0644 'openzwave/goodway/td14010.xml' +maybe chmod 0755 'openzwave/gr' +maybe chmod 0644 'openzwave/gr/gr-302n.xml' +maybe chmod 0644 'openzwave/gr/gr105.xml' +maybe chmod 0644 'openzwave/gr/gr105n.xml' +maybe chmod 0644 'openzwave/gr/grb3.xml' +maybe chmod 0755 'openzwave/graber' +maybe chmod 0644 'openzwave/graber/brz1.xml' +maybe chmod 0644 'openzwave/graber/csz1.xml' +maybe chmod 0644 'openzwave/graber/mcz1.xml' +maybe chmod 0644 'openzwave/graber/rsz1.xml' +maybe chmod 0644 'openzwave/graber/vcz1.xml' +maybe chmod 0755 'openzwave/greenwave' +maybe chmod 0644 'openzwave/greenwave/gs1110-1-gr-1.xml' +maybe chmod 0644 'openzwave/greenwave/powernode1.xml' +maybe chmod 0644 'openzwave/greenwave/powernode6.xml' +maybe chmod 0755 'openzwave/guardtec' +maybe chmod 0644 'openzwave/guardtec/gkw2000d.xml' +maybe chmod 0755 'openzwave/hab' +maybe chmod 0644 'openzwave/hab/iblindsV2.xml' +maybe chmod 0644 'openzwave/hab/iblindsV3.xml' +maybe chmod 0755 'openzwave/hank' +maybe chmod 0644 'openzwave/hank/hkzw-dws01.xml' +maybe chmod 0644 'openzwave/hank/hkzw-fld01.xml' +maybe chmod 0644 'openzwave/hank/hkzw-ms01.xml' +maybe chmod 0644 'openzwave/hank/hkzw-ms02-200.xml' +maybe chmod 0644 'openzwave/hank/hkzw-ms02-300.xml' +maybe chmod 0644 'openzwave/hank/hkzw-rgb01.xml' +maybe chmod 0644 'openzwave/hank/hkzw-so01-smartplug.xml' +maybe chmod 0644 'openzwave/hank/hkzw-so03.xml' +maybe chmod 0644 'openzwave/hank/hkzw-so05-smartplug.xml' +maybe chmod 0644 'openzwave/hank/scenecontroller1.xml' +maybe chmod 0644 'openzwave/hank/scenecontroller4.xml' +maybe chmod 0755 'openzwave/heiman' +maybe chmod 0644 'openzwave/heiman/HS1CA-Z.xml' +maybe chmod 0644 'openzwave/heiman/HS1CG-Z.xml' +maybe chmod 0644 'openzwave/heiman/HS1DS-Z.xml' +maybe chmod 0644 'openzwave/heiman/HS1HT-Z.xml' +maybe chmod 0644 'openzwave/heiman/HS1MS-Z.xml' +maybe chmod 0644 'openzwave/heiman/HS1SA-Z.xml' +maybe chmod 0644 'openzwave/heiman/HS1WL-Z.xml' +maybe chmod 0644 'openzwave/heiman/HS2SK-Z.xml' +maybe chmod 0644 'openzwave/heiman/HS2WD-Z.xml' +maybe chmod 0755 'openzwave/heltun' +maybe chmod 0644 'openzwave/heltun/he-ft01.xml' +maybe chmod 0644 'openzwave/heltun/he-ht01.xml' +maybe chmod 0644 'openzwave/heltun/he-zw-sw-5a-1.xml' +maybe chmod 0644 'openzwave/heltun/he-zw-therm-fc1.xml' +maybe chmod 0644 'openzwave/heltun/he-zw-therm-fl2.xml' +maybe chmod 0755 'openzwave/homeseer' +maybe chmod 0644 'openzwave/homeseer/ezmotionplus.xml' +maybe chmod 0644 'openzwave/homeseer/hs-ds100plus.xml' +maybe chmod 0644 'openzwave/homeseer/hs-fc200plus.xml' +maybe chmod 0644 'openzwave/homeseer/hs-fls100plus.xml' +maybe chmod 0644 'openzwave/homeseer/hs-fs100plus.xml' +maybe chmod 0644 'openzwave/homeseer/hs-ls100plus.xml' +maybe chmod 0644 'openzwave/homeseer/hs-ms100plus.xml' +maybe chmod 0644 'openzwave/homeseer/hs-wd100plus.xml' +maybe chmod 0644 'openzwave/homeseer/hs-wd200plus.xml' +maybe chmod 0644 'openzwave/homeseer/hs-ws100plus.xml' +maybe chmod 0644 'openzwave/homeseer/hs-ws200plus.xml' +maybe chmod 0644 'openzwave/homeseer/hsm100.xml' +maybe chmod 0644 'openzwave/homeseer/hsm200.xml' +maybe chmod 0644 'openzwave/homeseer/ztroller.xml' +maybe chmod 0755 'openzwave/honeywell' +maybe chmod 0644 'openzwave/honeywell/2681-plugin-dimmer.xml' +maybe chmod 0644 'openzwave/honeywell/3830-zw3107.xml' +maybe chmod 0644 'openzwave/honeywell/39348-ZW4005.xml' +maybe chmod 0644 'openzwave/honeywell/39348-zw4008.xml' +maybe chmod 0644 'openzwave/honeywell/39349-ZW1002.xml' +maybe chmod 0644 'openzwave/honeywell/39351-ZW3005.xml' +maybe chmod 0644 'openzwave/honeywell/39351-ZW3010.xml' +maybe chmod 0644 'openzwave/honeywell/39357-ZW3004.xml' +maybe chmod 0644 'openzwave/honeywell/39358-ZW4002.xml' +maybe chmod 0644 'openzwave/honeywell/39449-ZW4106.xml' +maybe chmod 0644 'openzwave/honeywell/lynx-touch-l5100.xml' +maybe chmod 0644 'openzwave/honeywell/th6320zw2003.xml' +maybe chmod 0644 'openzwave/honeywell/th8320zw1000.xml' +maybe chmod 0755 'openzwave/horstmann' +maybe chmod 0644 'openzwave/horstmann/asrzw.xml' +maybe chmod 0644 'openzwave/horstmann/hrt4zw.xml' +maybe chmod 0644 'openzwave/horstmann/scsc17.xml' +maybe chmod 0644 'openzwave/horstmann/ses301.xml' +maybe chmod 0644 'openzwave/horstmann/ses302.xml' +maybe chmod 0644 'openzwave/horstmann/ses303.xml' +maybe chmod 0644 'openzwave/horstmann/sir321.xml' +maybe chmod 0644 'openzwave/horstmann/srt321.xml' +maybe chmod 0644 'openzwave/horstmann/srt323.xml' +maybe chmod 0644 'openzwave/horstmann/ssr302.xml' +maybe chmod 0644 'openzwave/horstmann/ssr303.xml' +maybe chmod 0755 'openzwave/icare' +maybe chmod 0644 'openzwave/icare/zw-66.xml' +maybe chmod 0755 'openzwave/idlock' +maybe chmod 0644 'openzwave/idlock/idlock101.xml' +maybe chmod 0644 'openzwave/idlock/idlock150.xml' +maybe chmod 0755 'openzwave/images' +maybe chmod 0755 'openzwave/images/2gig' +maybe chmod 0644 'openzwave/images/2gig/ct100.png' +maybe chmod 0644 'openzwave/images/2gig/ct32.png' +maybe chmod 0755 'openzwave/images/BeNext' +maybe chmod 0644 'openzwave/images/BeNext/AlarmSound.png' +maybe chmod 0644 'openzwave/images/BeNext/DoorSensor.png' +maybe chmod 0644 'openzwave/images/BeNext/Molite.png' +maybe chmod 0644 'openzwave/images/BeNext/P1dongle.png' +maybe chmod 0644 'openzwave/images/BeNext/TagReader.png' +maybe chmod 0644 'openzwave/images/BeNext/TagReader500.png' +maybe chmod 0644 'openzwave/images/BeNext/mydisplay.png' +maybe chmod 0644 'openzwave/images/BeNext/mygate.png' +maybe chmod 0644 'openzwave/images/DefaultProductImage.png' +maybe chmod 0755 'openzwave/images/abus' +maybe chmod 0644 'openzwave/images/abus/SHRM10000.jpg' +maybe chmod 0755 'openzwave/images/act' +maybe chmod 0644 'openzwave/images/act/lfm20.png' +maybe chmod 0644 'openzwave/images/act/zdm230.png' +maybe chmod 0644 'openzwave/images/act/zdp100.png' +maybe chmod 0644 'openzwave/images/act/zir010.png' +maybe chmod 0644 'openzwave/images/act/zrm230.png' +maybe chmod 0644 'openzwave/images/act/zrp100.png' +maybe chmod 0644 'openzwave/images/act/zrw103.png' +maybe chmod 0644 'openzwave/images/act/zrw230.png' +maybe chmod 0755 'openzwave/images/aeotec' +maybe chmod 0644 'openzwave/images/aeotec/dsa03202.png' +maybe chmod 0644 'openzwave/images/aeotec/dsa38.png' +maybe chmod 0644 'openzwave/images/aeotec/dsb04100.png' +maybe chmod 0644 'openzwave/images/aeotec/dsb05.png' +maybe chmod 0644 'openzwave/images/aeotec/dsb09104.png' +maybe chmod 0644 'openzwave/images/aeotec/dsb28-zweu.png' +maybe chmod 0644 'openzwave/images/aeotec/dsb28.png' +maybe chmod 0644 'openzwave/images/aeotec/dsb29.png' +maybe chmod 0644 'openzwave/images/aeotec/dsc06106.png' +maybe chmod 0644 'openzwave/images/aeotec/dsc10.png' +maybe chmod 0644 'openzwave/images/aeotec/dsc11.png' +maybe chmod 0644 'openzwave/images/aeotec/dsc14104.png' +maybe chmod 0644 'openzwave/images/aeotec/dsc18103.png' +maybe chmod 0644 'openzwave/images/aeotec/dsc19103.png' +maybe chmod 0644 'openzwave/images/aeotec/dsc24.png' +maybe chmod 0644 'openzwave/images/aeotec/dsc26103.png' +maybe chmod 0644 'openzwave/images/aeotec/dsc27103.png' +maybe chmod 0644 'openzwave/images/aeotec/dsc35103.png' +maybe chmod 0644 'openzwave/images/aeotec/dsd37.png' +maybe chmod 0644 'openzwave/images/aeotec/zw056.png' +maybe chmod 0644 'openzwave/images/aeotec/zw062.png' +maybe chmod 0644 'openzwave/images/aeotec/zw074.png' +maybe chmod 0644 'openzwave/images/aeotec/zw075.png' +maybe chmod 0644 'openzwave/images/aeotec/zw078.png' +maybe chmod 0644 'openzwave/images/aeotec/zw080.png' +maybe chmod 0644 'openzwave/images/aeotec/zw088.png' +maybe chmod 0644 'openzwave/images/aeotec/zw089.png' +maybe chmod 0644 'openzwave/images/aeotec/zw090.png' +maybe chmod 0644 'openzwave/images/aeotec/zw095.png' +maybe chmod 0644 'openzwave/images/aeotec/zw096.png' +maybe chmod 0644 'openzwave/images/aeotec/zw097.png' +maybe chmod 0644 'openzwave/images/aeotec/zw098.png' +maybe chmod 0644 'openzwave/images/aeotec/zw099.png' +maybe chmod 0644 'openzwave/images/aeotec/zw100.png' +maybe chmod 0644 'openzwave/images/aeotec/zw111.png' +maybe chmod 0644 'openzwave/images/aeotec/zw112.png' +maybe chmod 0644 'openzwave/images/aeotec/zw116.png' +maybe chmod 0644 'openzwave/images/aeotec/zw117.png' +maybe chmod 0644 'openzwave/images/aeotec/zw120.png' +maybe chmod 0644 'openzwave/images/aeotec/zw121.png' +maybe chmod 0644 'openzwave/images/aeotec/zw122.png' +maybe chmod 0644 'openzwave/images/aeotec/zw129.png' +maybe chmod 0644 'openzwave/images/aeotec/zw130.png' +maybe chmod 0644 'openzwave/images/aeotec/zw132.png' +maybe chmod 0644 'openzwave/images/aeotec/zw139.png' +maybe chmod 0644 'openzwave/images/aeotec/zw140.png' +maybe chmod 0644 'openzwave/images/aeotec/zw141.png' +maybe chmod 0644 'openzwave/images/aeotec/zw162.png' +maybe chmod 0644 'openzwave/images/aeotec/zw164.png' +maybe chmod 0644 'openzwave/images/aeotec/zw187.png' +maybe chmod 0644 'openzwave/images/aeotec/zw189.png' +maybe chmod 0644 'openzwave/images/aeotec/zw195.png' +maybe chmod 0644 'openzwave/images/aeotec/zwa001.png' +maybe chmod 0644 'openzwave/images/aeotec/zwa002.png' +maybe chmod 0644 'openzwave/images/aeotec/zwa003.png' +maybe chmod 0644 'openzwave/images/aeotec/zwa004.png' +maybe chmod 0644 'openzwave/images/aeotec/zwa005.png' +maybe chmod 0644 'openzwave/images/aeotec/zwa006.png' +maybe chmod 0644 'openzwave/images/aeotec/zwa009.png' +maybe chmod 0644 'openzwave/images/aeotec/zwa012.png' +maybe chmod 0644 'openzwave/images/aeotec/zwa019.png' +maybe chmod 0644 'openzwave/images/aeotec/zwa021.png' +maybe chmod 0755 'openzwave/images/airlinemechanical' +maybe chmod 0644 'openzwave/images/airlinemechanical/zds-ud10.png' +maybe chmod 0755 'openzwave/images/alfred' +maybe chmod 0644 'openzwave/images/alfred/DB2.png' +maybe chmod 0755 'openzwave/images/assa_abloy' +maybe chmod 0644 'openzwave/images/assa_abloy/ConexisL1.png' +maybe chmod 0644 'openzwave/images/assa_abloy/KeyfreeConnected-plus.png' +maybe chmod 0644 'openzwave/images/assa_abloy/KeyfreeConnected.png' +maybe chmod 0644 'openzwave/images/assa_abloy/PushButtonDeadbolt.png' +maybe chmod 0644 'openzwave/images/assa_abloy/TouchDeadbolt.png' +maybe chmod 0644 'openzwave/images/assa_abloy/TouchLever.png' +maybe chmod 0644 'openzwave/images/assa_abloy/nexTouch.png' +maybe chmod 0644 'openzwave/images/assa_abloy/yrd1x0.png' +maybe chmod 0755 'openzwave/images/august' +maybe chmod 0644 'openzwave/images/august/asl-03.png' +maybe chmod 0755 'openzwave/images/buffalo' +maybe chmod 0644 'openzwave/images/buffalo/hw-100v15a-zw.png' +maybe chmod 0755 'openzwave/images/building36' +maybe chmod 0644 'openzwave/images/building36/b36-t10.png' +maybe chmod 0755 'openzwave/images/comfort' +maybe chmod 0644 'openzwave/images/comfort/ucm.png' +maybe chmod 0755 'openzwave/images/connecthome' +maybe chmod 0644 'openzwave/images/connecthome/CH_201.png' +maybe chmod 0755 'openzwave/images/cooper' +maybe chmod 0644 'openzwave/images/cooper/RF9501.png' +maybe chmod 0644 'openzwave/images/cooper/RF9505-T.png' +maybe chmod 0644 'openzwave/images/cooper/RF9517.png' +maybe chmod 0644 'openzwave/images/cooper/RF9540-N.png' +maybe chmod 0644 'openzwave/images/cooper/RF9542-Z.png' +maybe chmod 0644 'openzwave/images/cooper/rf9534.png' +maybe chmod 0755 'openzwave/images/danfoss' +maybe chmod 0644 'openzwave/images/danfoss/living.png' +maybe chmod 0644 'openzwave/images/danfoss/rsroom.png' +maybe chmod 0644 'openzwave/images/danfoss/z.png' +maybe chmod 0755 'openzwave/images/devolo' +maybe chmod 0644 'openzwave/images/devolo/mt02648.png' +maybe chmod 0644 'openzwave/images/devolo/mt02755.png' +maybe chmod 0644 'openzwave/images/devolo/mt02758.png' +maybe chmod 0644 'openzwave/images/devolo/mt2646.png' +maybe chmod 0644 'openzwave/images/devolo/mt2647.png' +maybe chmod 0644 'openzwave/images/devolo/mt2652.png' +maybe chmod 0644 'openzwave/images/devolo/mt2756.png' +maybe chmod 0644 'openzwave/images/devolo/mt2759.png' +maybe chmod 0644 'openzwave/images/devolo/mt2760.png' +maybe chmod 0644 'openzwave/images/devolo/mt2761.png' +maybe chmod 0755 'openzwave/images/diehlcontrols' +maybe chmod 0644 'openzwave/images/diehlcontrols/766366.png' +maybe chmod 0755 'openzwave/images/dlink' +maybe chmod 0644 'openzwave/images/dlink/dch-z110.png' +maybe chmod 0644 'openzwave/images/dlink/dch-z120.png' +maybe chmod 0644 'openzwave/images/dlink/dch-z210.png' +maybe chmod 0644 'openzwave/images/dlink/dch-z510.png' +maybe chmod 0755 'openzwave/images/dome' +maybe chmod 0644 'openzwave/images/dome/0002.png' +maybe chmod 0644 'openzwave/images/dome/0085.png' +maybe chmod 0644 'openzwave/images/dome/0086.png' +maybe chmod 0644 'openzwave/images/dome/0088.png' +maybe chmod 0644 'openzwave/images/dome/0201.png' +maybe chmod 0644 'openzwave/images/dome/dmex1.png' +maybe chmod 0755 'openzwave/images/domitech' +maybe chmod 0644 'openzwave/images/domitech/zb22uk.png' +maybe chmod 0644 'openzwave/images/domitech/ze27eu.png' +maybe chmod 0755 'openzwave/images/dragontech' +maybe chmod 0644 'openzwave/images/dragontech/wd-100.png' +maybe chmod 0755 'openzwave/images/duwi' +maybe chmod 0644 'openzwave/images/duwi/ZWES1000.png' +maybe chmod 0644 'openzwave/images/duwi/zw-edan-300.png' +maybe chmod 0644 'openzwave/images/duwi/zw-zdan-300.png' +maybe chmod 0644 'openzwave/images/duwi/zwws.png' +maybe chmod 0755 'openzwave/images/ecodim' +maybe chmod 0644 'openzwave/images/ecodim/0.7.jpg' +maybe chmod 0755 'openzwave/images/ecolink' +maybe chmod 0644 'openzwave/images/ecolink/doorwindow.png' +maybe chmod 0644 'openzwave/images/ecolink/firefighter.png' +maybe chmod 0644 'openzwave/images/ecolink/floodfreeze.png' +maybe chmod 0644 'openzwave/images/ecolink/motion.png' +maybe chmod 0644 'openzwave/images/ecolink/sensor.png' +maybe chmod 0644 'openzwave/images/ecolink/tiltsensor.png' +maybe chmod 0755 'openzwave/images/econet' +maybe chmod 0644 'openzwave/images/econet/ezw1204.png' +maybe chmod 0755 'openzwave/images/electronicsolutions' +maybe chmod 0644 'openzwave/images/electronicsolutions/dbmz.png' +maybe chmod 0755 'openzwave/images/enblink' +maybe chmod 0644 'openzwave/images/enblink/ss201-us-w_1308.png' +maybe chmod 0755 'openzwave/images/enerwave' +maybe chmod 0644 'openzwave/images/enerwave/zw15rmplus.png' +maybe chmod 0644 'openzwave/images/enerwave/zw20r.png' +maybe chmod 0644 'openzwave/images/enerwave/zw20rm.png' +maybe chmod 0644 'openzwave/images/enerwave/zwn-bpc.png' +maybe chmod 0644 'openzwave/images/enerwave/zwnrsm1plus.png' +maybe chmod 0644 'openzwave/images/enerwave/zwnrsm2plus.png' +maybe chmod 0755 'openzwave/images/eurotronic' +maybe chmod 0644 'openzwave/images/eurotronic/eur_airquality.png' +maybe chmod 0644 'openzwave/images/eurotronic/eur_cometz.png' +maybe chmod 0644 'openzwave/images/eurotronic/eur_spiritz.png' +maybe chmod 0644 'openzwave/images/eurotronic/eur_stellaz.png' +maybe chmod 0644 'openzwave/images/eurotronic/eur_temphumid.png' +maybe chmod 0755 'openzwave/images/everspring' +maybe chmod 0644 'openzwave/images/everspring/ad146.png' +maybe chmod 0644 'openzwave/images/everspring/ad147.png' +maybe chmod 0644 'openzwave/images/everspring/an157.png' +maybe chmod 0644 'openzwave/images/everspring/an158.png' +maybe chmod 0644 'openzwave/images/everspring/an163.png' +maybe chmod 0644 'openzwave/images/everspring/an179.png' +maybe chmod 0644 'openzwave/images/everspring/an180.png' +maybe chmod 0644 'openzwave/images/everspring/an181.png' +maybe chmod 0644 'openzwave/images/everspring/hac01.png' +maybe chmod 0644 'openzwave/images/everspring/han01.png' +maybe chmod 0644 'openzwave/images/everspring/han02-1.png' +maybe chmod 0644 'openzwave/images/everspring/hsm02.png' +maybe chmod 0644 'openzwave/images/everspring/hsp02.png' +maybe chmod 0644 'openzwave/images/everspring/lptdm1u.png' +maybe chmod 0644 'openzwave/images/everspring/se812.png' +maybe chmod 0644 'openzwave/images/everspring/sf812.png' +maybe chmod 0644 'openzwave/images/everspring/sm103.png' +maybe chmod 0644 'openzwave/images/everspring/sp103.png' +maybe chmod 0644 'openzwave/images/everspring/sp814.png' +maybe chmod 0644 'openzwave/images/everspring/sp815.png' +maybe chmod 0644 'openzwave/images/everspring/sp816.png' +maybe chmod 0644 'openzwave/images/everspring/st812.png' +maybe chmod 0644 'openzwave/images/everspring/st814.png' +maybe chmod 0644 'openzwave/images/everspring/st815.png' +maybe chmod 0644 'openzwave/images/everspring/tse03.png' +maybe chmod 0755 'openzwave/images/evolve' +maybe chmod 0644 'openzwave/images/evolve/lfm-20.png' +maybe chmod 0644 'openzwave/images/evolve/ltm-5.png' +maybe chmod 0755 'openzwave/images/fakro' +maybe chmod 0644 'openzwave/images/fakro/arz.png' +maybe chmod 0644 'openzwave/images/fakro/zws12.png' +maybe chmod 0755 'openzwave/images/fibaro' +maybe chmod 0644 'openzwave/images/fibaro/fgbs222.png' +maybe chmod 0644 'openzwave/images/fibaro/fgcd001.png' +maybe chmod 0644 'openzwave/images/fibaro/fgd212.png' +maybe chmod 0644 'openzwave/images/fibaro/fgdw2.png' +maybe chmod 0644 'openzwave/images/fibaro/fgfs101zw5.png' +maybe chmod 0644 'openzwave/images/fibaro/fggc001.png' +maybe chmod 0644 'openzwave/images/fibaro/fgk001.png' +maybe chmod 0644 'openzwave/images/fibaro/fgk10x.png' +maybe chmod 0644 'openzwave/images/fibaro/fgkf601.png' +maybe chmod 0644 'openzwave/images/fibaro/fgms.png' +maybe chmod 0644 'openzwave/images/fibaro/fgmszw5.png' +maybe chmod 0644 'openzwave/images/fibaro/fgpb101.png' +maybe chmod 0644 'openzwave/images/fibaro/fgr223.png' +maybe chmod 0644 'openzwave/images/fibaro/fgrgbw442.png' +maybe chmod 0644 'openzwave/images/fibaro/fgrgbwm441.png' +maybe chmod 0644 'openzwave/images/fibaro/fgs213.png' +maybe chmod 0644 'openzwave/images/fibaro/fgs223.png' +maybe chmod 0644 'openzwave/images/fibaro/fgs224.png' +maybe chmod 0644 'openzwave/images/fibaro/fgsd002.png' +maybe chmod 0644 'openzwave/images/fibaro/fgt001.png' +maybe chmod 0644 'openzwave/images/fibaro/fgwd111.png' +maybe chmod 0644 'openzwave/images/fibaro/fgwds221.png' +maybe chmod 0644 'openzwave/images/fibaro/fgwoe.png' +maybe chmod 0644 'openzwave/images/fibaro/fgwpe.png' +maybe chmod 0644 'openzwave/images/fibaro/fgwpfzw5.png' +maybe chmod 0644 'openzwave/images/fibaro/fgwpg111.png' +maybe chmod 0644 'openzwave/images/fibaro/fgwr111.png' +maybe chmod 0755 'openzwave/images/firstalert' +maybe chmod 0644 'openzwave/images/firstalert/zcombo-g.png' +maybe chmod 0644 'openzwave/images/firstalert/zcombo.png' +maybe chmod 0644 'openzwave/images/firstalert/zsmoke.png' +maybe chmod 0755 'openzwave/images/followgood' +maybe chmod 0644 'openzwave/images/followgood/swz-1002.png' +maybe chmod 0755 'openzwave/images/forest' +maybe chmod 0644 'openzwave/images/forest/fs2z5232000002.png' +maybe chmod 0755 'openzwave/images/fortrezz' +maybe chmod 0644 'openzwave/images/fortrezz/fmi.png' +maybe chmod 0644 'openzwave/images/fortrezz/fts05p.png' +maybe chmod 0644 'openzwave/images/fortrezz/gdc1_fortrezz_1501.png' +maybe chmod 0644 'openzwave/images/fortrezz/mimo2plus.png' +maybe chmod 0644 'openzwave/images/fortrezz/mimolite.png' +maybe chmod 0644 'openzwave/images/fortrezz/ssa2.png' +maybe chmod 0644 'openzwave/images/fortrezz/ssa3.png' +maybe chmod 0644 'openzwave/images/fortrezz/wv01.png' +maybe chmod 0644 'openzwave/images/fortrezz/wwa-01aa.png' +maybe chmod 0644 'openzwave/images/fortrezz/wwa02.png' +maybe chmod 0755 'openzwave/images/frostdale' +maybe chmod 0644 'openzwave/images/frostdale/fdn2311.png' +maybe chmod 0755 'openzwave/images/ge' +maybe chmod 0644 'openzwave/images/ge/12719-plugin-switch.png' +maybe chmod 0644 'openzwave/images/ge/12724-dimmer.png' +maybe chmod 0644 'openzwave/images/ge/12727.png' +maybe chmod 0644 'openzwave/images/ge/14280-plugin-dimmer.png' +maybe chmod 0644 'openzwave/images/ge/14282-plugin-switch.png' +maybe chmod 0644 'openzwave/images/ge/14284.png' +maybe chmod 0644 'openzwave/images/ge/14285.png' +maybe chmod 0644 'openzwave/images/ge/14288-outlet.png' +maybe chmod 0644 'openzwave/images/ge/14291-switch.png' +maybe chmod 0644 'openzwave/images/ge/14292-toggle-switch.png' +maybe chmod 0644 'openzwave/images/ge/14294-dimmer.png' +maybe chmod 0644 'openzwave/images/ge/14295-dimmer-toggle.png' +maybe chmod 0644 'openzwave/images/ge/14298.png' +maybe chmod 0644 'openzwave/images/ge/26931-motion-switch.png' +maybe chmod 0644 'openzwave/images/ge/26933-motion-dimmer.png' +maybe chmod 0644 'openzwave/images/ge/28167-plugin-dimmer.png' +maybe chmod 0644 'openzwave/images/ge/28169-plugin-switch.png' +maybe chmod 0644 'openzwave/images/ge/45604.png' +maybe chmod 0644 'openzwave/images/ge/46201-switch.png' +maybe chmod 0644 'openzwave/images/ge/46202-switch.png' +maybe chmod 0644 'openzwave/images/ge/46203-dimmer.png' +maybe chmod 0644 'openzwave/images/ge/46204-dimmer-toggle.png' +maybe chmod 0644 'openzwave/images/ge/dimmer.png' +maybe chmod 0644 'openzwave/images/ge/dimmer_module.png' +maybe chmod 0644 'openzwave/images/ge/hinge-pin.png' +maybe chmod 0644 'openzwave/images/ge/receptacle.png' +maybe chmod 0644 'openzwave/images/ge/relay.png' +maybe chmod 0644 'openzwave/images/ge/ze26i.png' +maybe chmod 0644 'openzwave/images/ge/zw6302.png' +maybe chmod 0755 'openzwave/images/goodway' +maybe chmod 0644 'openzwave/images/goodway/td14010.png' +maybe chmod 0755 'openzwave/images/gr' +maybe chmod 0644 'openzwave/images/gr/gr-302n.png' +maybe chmod 0644 'openzwave/images/gr/gr105.png' +maybe chmod 0644 'openzwave/images/gr/gr105n.png' +maybe chmod 0755 'openzwave/images/graber' +maybe chmod 0644 'openzwave/images/graber/brz1.png' +maybe chmod 0644 'openzwave/images/graber/csz1.png' +maybe chmod 0644 'openzwave/images/graber/mcz1.png' +maybe chmod 0644 'openzwave/images/graber/rsz1.png' +maybe chmod 0644 'openzwave/images/graber/vcz1.png' +maybe chmod 0755 'openzwave/images/greenwave' +maybe chmod 0644 'openzwave/images/greenwave/gs1110-1-gr-1.png' +maybe chmod 0644 'openzwave/images/greenwave/powernode1.png' +maybe chmod 0644 'openzwave/images/greenwave/powernode6.png' +maybe chmod 0755 'openzwave/images/guardtec' +maybe chmod 0644 'openzwave/images/guardtec/gkw2000d.png' +maybe chmod 0755 'openzwave/images/hab' +maybe chmod 0644 'openzwave/images/hab/iblinds.png' +maybe chmod 0644 'openzwave/images/hab/iblindsV3.png' +maybe chmod 0755 'openzwave/images/hank' +maybe chmod 0644 'openzwave/images/hank/hkzw-dws01.png' +maybe chmod 0644 'openzwave/images/hank/hkzw-fld01.png' +maybe chmod 0644 'openzwave/images/hank/hkzw-ms01.png' +maybe chmod 0644 'openzwave/images/hank/hkzw-ms02-200.png' +maybe chmod 0644 'openzwave/images/hank/hkzw-rgb01.png' +maybe chmod 0644 'openzwave/images/hank/hkzw-so01-smartplug.png' +maybe chmod 0644 'openzwave/images/hank/hkzw-so03.png' +maybe chmod 0644 'openzwave/images/hank/hkzw-so05-smartplug.png' +maybe chmod 0644 'openzwave/images/hank/scenecontroller1.png' +maybe chmod 0644 'openzwave/images/hank/scenecontroller4.png' +maybe chmod 0755 'openzwave/images/heiman' +maybe chmod 0644 'openzwave/images/heiman/HS1CA-Z.png' +maybe chmod 0644 'openzwave/images/heiman/HS1CG-Z.png' +maybe chmod 0644 'openzwave/images/heiman/HS1DS-Z.png' +maybe chmod 0644 'openzwave/images/heiman/HS1HT-Z.png' +maybe chmod 0644 'openzwave/images/heiman/HS1MS-Z.png' +maybe chmod 0644 'openzwave/images/heiman/HS1SA-Z.png' +maybe chmod 0644 'openzwave/images/heiman/HS1WL-Z.png' +maybe chmod 0644 'openzwave/images/heiman/HS2SK-Z.png' +maybe chmod 0755 'openzwave/images/heltun' +maybe chmod 0644 'openzwave/images/heltun/he-ft01.png' +maybe chmod 0644 'openzwave/images/heltun/he-ht01.png' +maybe chmod 0755 'openzwave/images/homeseer' +maybe chmod 0644 'openzwave/images/homeseer/hs-ds100plus.png' +maybe chmod 0644 'openzwave/images/homeseer/hs-fc200plus.png' +maybe chmod 0644 'openzwave/images/homeseer/hs-fls100plus.png' +maybe chmod 0644 'openzwave/images/homeseer/hs-ls100plus.png' +maybe chmod 0644 'openzwave/images/homeseer/hs-ms100plus.png' +maybe chmod 0644 'openzwave/images/homeseer/hs-wd100plus.png' +maybe chmod 0644 'openzwave/images/homeseer/hs-wd200plus.png' +maybe chmod 0644 'openzwave/images/homeseer/hs-ws100plus.png' +maybe chmod 0644 'openzwave/images/homeseer/hs-ws200plus.png' +maybe chmod 0644 'openzwave/images/homeseer/hsm200.png' +maybe chmod 0755 'openzwave/images/honeywell' +maybe chmod 0644 'openzwave/images/honeywell/2681-plugin-dimmer.png' +maybe chmod 0644 'openzwave/images/honeywell/3830-zw3107.png' +maybe chmod 0644 'openzwave/images/honeywell/39348-ZW4005.png' +maybe chmod 0644 'openzwave/images/honeywell/39348-ZW4008.png' +maybe chmod 0644 'openzwave/images/honeywell/39349-ZW1002.png' +maybe chmod 0644 'openzwave/images/honeywell/39351-ZW3005.png' +maybe chmod 0644 'openzwave/images/honeywell/39357-ZW3004.png' +maybe chmod 0644 'openzwave/images/honeywell/39358-ZW4002.png' +maybe chmod 0644 'openzwave/images/honeywell/39449-ZW4106.png' +maybe chmod 0644 'openzwave/images/honeywell/lynx-touch-l5100.png' +maybe chmod 0644 'openzwave/images/honeywell/th6320zw2003.png' +maybe chmod 0644 'openzwave/images/honeywell/th8320zw1000.png' +maybe chmod 0755 'openzwave/images/horstmann' +maybe chmod 0644 'openzwave/images/horstmann/asrzw.png' +maybe chmod 0644 'openzwave/images/horstmann/hrt4zw.png' +maybe chmod 0644 'openzwave/images/horstmann/scsc17.png' +maybe chmod 0644 'openzwave/images/horstmann/ses301.png' +maybe chmod 0644 'openzwave/images/horstmann/ses302.png' +maybe chmod 0644 'openzwave/images/horstmann/ses303.png' +maybe chmod 0644 'openzwave/images/horstmann/sir321.png' +maybe chmod 0644 'openzwave/images/horstmann/srt321.png' +maybe chmod 0644 'openzwave/images/horstmann/srt323.png' +maybe chmod 0644 'openzwave/images/horstmann/ssr302.png' +maybe chmod 0644 'openzwave/images/horstmann/ssr303.png' +maybe chmod 0755 'openzwave/images/icare' +maybe chmod 0644 'openzwave/images/icare/zw-66.png' +maybe chmod 0755 'openzwave/images/idlock' +maybe chmod 0644 'openzwave/images/idlock/idlock101.png' +maybe chmod 0644 'openzwave/images/idlock/idlock150.png' +maybe chmod 0755 'openzwave/images/ingersoll' +maybe chmod 0644 'openzwave/images/ingersoll/dwzwave1.png' +maybe chmod 0755 'openzwave/images/inovelli' +maybe chmod 0644 'openzwave/images/inovelli/lzw30-sn.png' +maybe chmod 0644 'openzwave/images/inovelli/lzw30.png' +maybe chmod 0644 'openzwave/images/inovelli/lzw31-sn.png' +maybe chmod 0644 'openzwave/images/inovelli/lzw31.png' +maybe chmod 0644 'openzwave/images/inovelli/lzw36.png' +maybe chmod 0644 'openzwave/images/inovelli/lzw40.png' +maybe chmod 0644 'openzwave/images/inovelli/lzw41.png' +maybe chmod 0644 'openzwave/images/inovelli/lzw42.png' +maybe chmod 0644 'openzwave/images/inovelli/lzw60.png' +maybe chmod 0644 'openzwave/images/inovelli/nzw30.png' +maybe chmod 0644 'openzwave/images/inovelli/simple_module.png' +maybe chmod 0755 'openzwave/images/iwatsu' +maybe chmod 0644 'openzwave/images/iwatsu/ne-4ct-2p.png' +maybe chmod 0644 'openzwave/images/iwatsu/ne-4ct.png' +maybe chmod 0755 'openzwave/images/jasco' +maybe chmod 0644 'openzwave/images/jasco/45601.png' +maybe chmod 0755 'openzwave/images/kaipule' +maybe chmod 0644 'openzwave/images/kaipule/im20.png' +maybe chmod 0755 'openzwave/images/kwikset' +maybe chmod 0644 'openzwave/images/kwikset/888.png' +maybe chmod 0644 'openzwave/images/kwikset/914c.png' +maybe chmod 0644 'openzwave/images/kwikset/916.jpg' +maybe chmod 0644 'openzwave/images/kwikset/smartcode.png' +maybe chmod 0755 'openzwave/images/leviton' +maybe chmod 0644 'openzwave/images/leviton/dz15s.png' +maybe chmod 0644 'openzwave/images/leviton/dz6hd.png' +maybe chmod 0644 'openzwave/images/leviton/dzpa1.png' +maybe chmod 0644 'openzwave/images/leviton/dzpd3.png' +maybe chmod 0644 'openzwave/images/leviton/vrcs2.png' +maybe chmod 0644 'openzwave/images/leviton/vrf01.png' +maybe chmod 0644 'openzwave/images/leviton/vri10.png' +maybe chmod 0644 'openzwave/images/leviton/vrpa1.png' +maybe chmod 0644 'openzwave/images/leviton/vrpd3.png' +maybe chmod 0644 'openzwave/images/leviton/vrs15.png' +maybe chmod 0644 'openzwave/images/leviton/zw4sf.png' +maybe chmod 0755 'openzwave/images/linear' +maybe chmod 0644 'openzwave/images/linear/LB60Z-1.png' +maybe chmod 0644 'openzwave/images/linear/WD500Z5-1.png' +maybe chmod 0644 'openzwave/images/linear/WT00Z5-1.png' +maybe chmod 0644 'openzwave/images/linear/gd00z-7.png' +maybe chmod 0644 'openzwave/images/linear/ngd00z.png' +maybe chmod 0755 'openzwave/images/logicsoft' +maybe chmod 0644 'openzwave/images/logicsoft/ZDB5100.png' +maybe chmod 0644 'openzwave/images/logicsoft/ZHC5010.png' +maybe chmod 0755 'openzwave/images/mcohome' +maybe chmod 0644 'openzwave/images/mcohome/mh7h.png' +maybe chmod 0644 'openzwave/images/mcohome/mh8fceu0803.png' +maybe chmod 0644 'openzwave/images/mcohome/mhp220.png' +maybe chmod 0644 'openzwave/images/mcohome/mhp511.png' +maybe chmod 0755 'openzwave/images/merten' +maybe chmod 0644 'openzwave/images/merten/5044xx.png' +maybe chmod 0644 'openzwave/images/merten/5046xx.png' +maybe chmod 0644 'openzwave/images/merten/506004.png' +maybe chmod 0644 'openzwave/images/merten/508244.png' +maybe chmod 0755 'openzwave/images/miyakawaelectric' +maybe chmod 0644 'openzwave/images/miyakawaelectric/me-d101.png' +maybe chmod 0755 'openzwave/images/namron' +maybe chmod 0644 'openzwave/images/namron/1402756.png' +maybe chmod 0755 'openzwave/images/nexia' +maybe chmod 0644 'openzwave/images/nexia/db100z.png' +maybe chmod 0644 'openzwave/images/nexia/th100nx.png' +maybe chmod 0755 'openzwave/images/nodon' +maybe chmod 0644 'openzwave/images/nodon/asp3100SmartPlug.png' +maybe chmod 0644 'openzwave/images/nodon/crc3100OctanRemote.png' +maybe chmod 0644 'openzwave/images/nodon/crc360xSofremote.png' +maybe chmod 0644 'openzwave/images/nodon/cws3101wallswitch.png' +maybe chmod 0644 'openzwave/images/nodon/msp31xxMicroSmartPlug.png' +maybe chmod 0755 'openzwave/images/northq' +maybe chmod 0644 'openzwave/images/northq/nq92021.png' +maybe chmod 0755 'openzwave/images/oomi' +maybe chmod 0644 'openzwave/images/oomi/ft100.png' +maybe chmod 0644 'openzwave/images/oomi/ft111.png' +maybe chmod 0644 'openzwave/images/oomi/ft112.png' +maybe chmod 0644 'openzwave/images/oomi/ft118.png' +maybe chmod 0755 'openzwave/images/permundo' +maybe chmod 0644 'openzwave/images/permundo/psc132zw.png' +maybe chmod 0644 'openzwave/images/permundo/psc234zw.png' +maybe chmod 0755 'openzwave/images/philio' +maybe chmod 0644 'openzwave/images/philio/pad02.png' +maybe chmod 0644 'openzwave/images/philio/pan04.png' +maybe chmod 0644 'openzwave/images/philio/pan05.png' +maybe chmod 0644 'openzwave/images/philio/pan06.png' +maybe chmod 0644 'openzwave/images/philio/pan08.png' +maybe chmod 0644 'openzwave/images/philio/pan11-1.png' +maybe chmod 0644 'openzwave/images/philio/pan11.png' +maybe chmod 0644 'openzwave/images/philio/pan16.png' +maybe chmod 0644 'openzwave/images/philio/phpab01.png' +maybe chmod 0644 'openzwave/images/philio/phpat02.png' +maybe chmod 0644 'openzwave/images/philio/phpsg01.png' +maybe chmod 0644 'openzwave/images/philio/pse02.png' +maybe chmod 0644 'openzwave/images/philio/psm02.png' +maybe chmod 0644 'openzwave/images/philio/psp05.png' +maybe chmod 0644 'openzwave/images/philio/psr03-1b.png' +maybe chmod 0644 'openzwave/images/philio/psr04.png' +maybe chmod 0644 'openzwave/images/philio/pst02-1c.png' +maybe chmod 0644 'openzwave/images/philio/pst02-b.png' +maybe chmod 0644 'openzwave/images/philio/pst02.png' +maybe chmod 0755 'openzwave/images/polycontrol' +maybe chmod 0644 'openzwave/images/polycontrol/doorlock.png' +maybe chmod 0644 'openzwave/images/polycontrol/doorlockv3.png' +maybe chmod 0755 'openzwave/images/popp' +maybe chmod 0644 'openzwave/images/popp/004407.png' +maybe chmod 0644 'openzwave/images/popp/009303.png' +maybe chmod 0644 'openzwave/images/popp/009402.png' +maybe chmod 0644 'openzwave/images/popp/012501.png' +maybe chmod 0644 'openzwave/images/popp/700045.png' +maybe chmod 0644 'openzwave/images/popp/700168.png' +maybe chmod 0644 'openzwave/images/popp/700397.png' +maybe chmod 0644 'openzwave/images/popp/701202.png' +maybe chmod 0644 'openzwave/images/popp/dwt.png' +maybe chmod 0644 'openzwave/images/popp/smoke-detector.png' +maybe chmod 0644 'openzwave/images/popp/solar-siren.png' +maybe chmod 0644 'openzwave/images/popp/zweather.png' +maybe chmod 0755 'openzwave/images/prowell' +maybe chmod 0644 'openzwave/images/prowell/zw-702.png' +maybe chmod 0755 'openzwave/images/q-light' +maybe chmod 0644 'openzwave/images/q-light/q-light_puck.png' +maybe chmod 0644 'openzwave/images/q-light/q-light_zerodim.png' +maybe chmod 0644 'openzwave/images/q-light/q-light_zerodim_2pol.png' +maybe chmod 0755 'openzwave/images/qees' +maybe chmod 0644 'openzwave/images/qees/reto-dimmer-plus.png' +maybe chmod 0644 'openzwave/images/qees/reto-plugin-switch.png' +maybe chmod 0755 'openzwave/images/qubino' +maybe chmod 0644 'openzwave/images/qubino/ZMNHADx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHBDx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHCDx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHDA2.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHDDx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHIDx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHNDx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHODx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHQDx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHSDx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHTDx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHVDx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHWD1.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNHYDx.png' +maybe chmod 0644 'openzwave/images/qubino/ZMNKADx.png' +maybe chmod 0644 'openzwave/images/qubino/zmnhxdx.png' +maybe chmod 0755 'openzwave/images/quby' +maybe chmod 0644 'openzwave/images/quby/qb2.png' +maybe chmod 0755 'openzwave/images/rcs' +maybe chmod 0644 'openzwave/images/rcs/em52-zw.png' +maybe chmod 0644 'openzwave/images/rcs/therm0009.png' +maybe chmod 0755 'openzwave/images/remotec' +maybe chmod 0644 'openzwave/images/remotec/bw8120eu.png' +maybe chmod 0644 'openzwave/images/remotec/zfm-80.png' +maybe chmod 0644 'openzwave/images/remotec/zrc-100eu.png' +maybe chmod 0644 'openzwave/images/remotec/zrc-90.png' +maybe chmod 0644 'openzwave/images/remotec/zts-110.png' +maybe chmod 0644 'openzwave/images/remotec/zts-500.png' +maybe chmod 0644 'openzwave/images/remotec/zurc.png' +maybe chmod 0644 'openzwave/images/remotec/zxt-120.png' +maybe chmod 0644 'openzwave/images/remotec/zxt-310.png' +maybe chmod 0644 'openzwave/images/remotec/zxt-600.png' +maybe chmod 0755 'openzwave/images/ring' +maybe chmod 0644 'openzwave/images/ring/PIR-SS.png' +maybe chmod 0755 'openzwave/images/schlage' +maybe chmod 0644 'openzwave/images/schlage/BE468ZP.png' +maybe chmod 0644 'openzwave/images/schlage/BE469.png' +maybe chmod 0644 'openzwave/images/schlage/BE469ZP.png' +maybe chmod 0644 'openzwave/images/schlage/fe599.png' +maybe chmod 0755 'openzwave/images/schlagelink' +maybe chmod 0644 'openzwave/images/schlagelink/41.png' +maybe chmod 0755 'openzwave/images/sensative' +maybe chmod 0644 'openzwave/images/sensative/strips.png' +maybe chmod 0644 'openzwave/images/sensative/stripscomfort.png' +maybe chmod 0755 'openzwave/images/sercomm' +maybe chmod 0644 'openzwave/images/sercomm/sw-clp01-eu.png' +maybe chmod 0755 'openzwave/images/shenzen_neo' +maybe chmod 0644 'openzwave/images/shenzen_neo/ls03ch.jpg' +maybe chmod 0644 'openzwave/images/shenzen_neo/nas-ab01z.png' +maybe chmod 0644 'openzwave/images/shenzen_neo/nas-ds01z.png' +maybe chmod 0644 'openzwave/images/shenzen_neo/nas-pd01z.png' +maybe chmod 0644 'openzwave/images/shenzen_neo/nas-pd02z.png' +maybe chmod 0644 'openzwave/images/shenzen_neo/nas-wr01z.png' +maybe chmod 0644 'openzwave/images/shenzen_neo/nas-wr01ze.png' +maybe chmod 0644 'openzwave/images/shenzen_neo/nas-ws02z.png' +maybe chmod 0755 'openzwave/images/shenzen_saykey' +maybe chmod 0644 'openzwave/images/shenzen_saykey/SK-3007-05.png' +maybe chmod 0755 'openzwave/images/simon' +maybe chmod 0644 'openzwave/images/simon/10002034-13X.png' +maybe chmod 0644 'openzwave/images/simon/10002080-13X.png' +maybe chmod 0755 'openzwave/images/smartthings' +maybe chmod 0644 'openzwave/images/smartthings/pgc401m.png' +maybe chmod 0644 'openzwave/images/smartthings/sth-eth200.png' +maybe chmod 0755 'openzwave/images/steinel' +maybe chmod 0644 'openzwave/images/steinel/is140-2.png' +maybe chmod 0644 'openzwave/images/steinel/l810-led-ihf.png' +maybe chmod 0644 'openzwave/images/steinel/rs-led-d2.png' +maybe chmod 0644 'openzwave/images/steinel/xled-home-2.png' +maybe chmod 0755 'openzwave/images/stelpro' +maybe chmod 0644 'openzwave/images/stelpro/stzw402.png' +maybe chmod 0755 'openzwave/images/sunricher' +maybe chmod 0644 'openzwave/images/sunricher/srzv9001k12dimz4.png' +maybe chmod 0644 'openzwave/images/sunricher/srzv9001k12dimz5.png' +maybe chmod 0644 'openzwave/images/sunricher/srzv9001k8.png' +maybe chmod 0644 'openzwave/images/sunricher/srzv9001t4dimeu.png' +maybe chmod 0644 'openzwave/images/sunricher/srzv9001tccteu.png' +maybe chmod 0644 'openzwave/images/sunricher/srzv9003t4rgbweu.png' +maybe chmod 0644 'openzwave/images/sunricher/srzv9101facct.png' +maybe chmod 0644 'openzwave/images/sunricher/srzv9101sachpeu.png' +maybe chmod 0644 'openzwave/images/sunricher/zv2835rac.png' +maybe chmod 0644 'openzwave/images/sunricher/zv9101.png' +maybe chmod 0755 'openzwave/images/swiid' +maybe chmod 0644 'openzwave/images/swiid/swiidinter.png' +maybe chmod 0755 'openzwave/images/technisat' +maybe chmod 0644 'openzwave/images/technisat/03009496.png' +maybe chmod 0644 'openzwave/images/technisat/03009497.png' +maybe chmod 0644 'openzwave/images/technisat/03009499.png' +maybe chmod 0755 'openzwave/images/telldus' +maybe chmod 0644 'openzwave/images/telldus/tzdw100.png' +maybe chmod 0644 'openzwave/images/telldus/tzwp100.png' +maybe chmod 0644 'openzwave/images/telldus/tzwp102.png' +maybe chmod 0755 'openzwave/images/there' +maybe chmod 0644 'openzwave/images/there/800z.png' +maybe chmod 0755 'openzwave/images/thermofloor' +maybe chmod 0644 'openzwave/images/thermofloor/Heatit-Z-Push-button-8-white.png' +maybe chmod 0644 'openzwave/images/thermofloor/heatit021.png' +maybe chmod 0644 'openzwave/images/thermofloor/heatit056.png' +maybe chmod 0644 'openzwave/images/thermofloor/heatit058.png' +maybe chmod 0644 'openzwave/images/thermofloor/heatit20a.png' +maybe chmod 0644 'openzwave/images/thermofloor/heatit_zdim.png' +maybe chmod 0755 'openzwave/images/trane' +maybe chmod 0644 'openzwave/images/trane/TZEMT400AB32MAA.png' +maybe chmod 0644 'openzwave/images/trane/TZEMT400BB32MAA.png' +maybe chmod 0644 'openzwave/images/trane/TZEMT524AA21MA.png' +maybe chmod 0755 'openzwave/images/vera' +maybe chmod 0644 'openzwave/images/vera/vera2.png' +maybe chmod 0755 'openzwave/images/vision' +maybe chmod 0644 'openzwave/images/vision/1701.png' +maybe chmod 0644 'openzwave/images/vision/brg1-433.png' +maybe chmod 0644 'openzwave/images/vision/zd2102.png' +maybe chmod 0644 'openzwave/images/vision/zd2105us5.png' +maybe chmod 0644 'openzwave/images/vision/zd2201.png' +maybe chmod 0644 'openzwave/images/vision/zd2301.png' +maybe chmod 0644 'openzwave/images/vision/zl7101us.png' +maybe chmod 0644 'openzwave/images/vision/zl7201us.png' +maybe chmod 0644 'openzwave/images/vision/zl7431.png' +maybe chmod 0644 'openzwave/images/vision/zl7432us.png' +maybe chmod 0644 'openzwave/images/vision/zm1601eu.png' +maybe chmod 0644 'openzwave/images/vision/zm1601eu5.png' +maybe chmod 0644 'openzwave/images/vision/zm1602eu5.png' +maybe chmod 0644 'openzwave/images/vision/zm1701.png' +maybe chmod 0644 'openzwave/images/vision/zp3102.png' +maybe chmod 0644 'openzwave/images/vision/zp3111.png' +maybe chmod 0644 'openzwave/images/vision/zr1202us.png' +maybe chmod 0644 'openzwave/images/vision/zs610eu.png' +maybe chmod 0644 'openzwave/images/vision/zu1401jp.png' +maybe chmod 0755 'openzwave/images/vitrum' +maybe chmod 0644 'openzwave/images/vitrum/vitrumI-Dimmer.png' +maybe chmod 0644 'openzwave/images/vitrum/vitrumI-Switch.png' +maybe chmod 0644 'openzwave/images/vitrum/vitrumII-Blind.png' +maybe chmod 0644 'openzwave/images/vitrum/vitrumII-Dimmer.png' +maybe chmod 0644 'openzwave/images/vitrum/vitrumII-Switch.png' +maybe chmod 0755 'openzwave/images/wenzhou' +maybe chmod 0644 'openzwave/images/wenzhou/tsp01.png' +maybe chmod 0644 'openzwave/images/wenzhou/tz55.png' +maybe chmod 0644 'openzwave/images/wenzhou/tz56.png' +maybe chmod 0644 'openzwave/images/wenzhou/tz65d.png' +maybe chmod 0644 'openzwave/images/wenzhou/tz66d.png' +maybe chmod 0644 'openzwave/images/wenzhou/tz67.png' +maybe chmod 0644 'openzwave/images/wenzhou/tz68.png' +maybe chmod 0644 'openzwave/images/wenzhou/tz69.png' +maybe chmod 0644 'openzwave/images/wenzhou/tz78.png' +maybe chmod 0644 'openzwave/images/wenzhou/tz88.png' +maybe chmod 0755 'openzwave/images/widom' +maybe chmod 0644 'openzwave/images/widom/DRY.png' +maybe chmod 0644 'openzwave/images/widom/UBS104.png' +maybe chmod 0644 'openzwave/images/widom/UME304C_S.png' +maybe chmod 0644 'openzwave/images/widom/UMS2.png' +maybe chmod 0644 'openzwave/images/widom/WDS.png' +maybe chmod 0644 'openzwave/images/widom/WDS2.png' +maybe chmod 0644 'openzwave/images/widom/WSP.png' +maybe chmod 0644 'openzwave/images/widom/WTED.png' +maybe chmod 0755 'openzwave/images/wink' +maybe chmod 0644 'openzwave/images/wink/wnk-mot1.png' +maybe chmod 0644 'openzwave/images/wink/wnk-sir1p.png' +maybe chmod 0755 'openzwave/images/zipato' +maybe chmod 0644 'openzwave/images/zipato/HS1CA-Z.png' +maybe chmod 0644 'openzwave/images/zipato/HS1CG-Z.png' +maybe chmod 0644 'openzwave/images/zipato/HS1SA-Z.png' +maybe chmod 0644 'openzwave/images/zipato/HS1WL-Z.png' +maybe chmod 0644 'openzwave/images/zipato/RGBBulb.png' +maybe chmod 0644 'openzwave/images/zipato/ne-nas-ab01z.png' +maybe chmod 0644 'openzwave/images/zipato/pan04.png' +maybe chmod 0644 'openzwave/images/zipato/phpab01.png' +maybe chmod 0644 'openzwave/images/zipato/pse02.png' +maybe chmod 0644 'openzwave/images/zipato/pst02.png' +maybe chmod 0644 'openzwave/images/zipato/vszd2102.png' +maybe chmod 0644 'openzwave/images/zipato/zd2301.png' +maybe chmod 0644 'openzwave/images/zipato/zp3102.png' +maybe chmod 0755 'openzwave/images/zooz' +maybe chmod 0644 'openzwave/images/zooz/zen06.png' +maybe chmod 0644 'openzwave/images/zooz/zen15.png' +maybe chmod 0644 'openzwave/images/zooz/zen16.png' +maybe chmod 0644 'openzwave/images/zooz/zen20.png' +maybe chmod 0644 'openzwave/images/zooz/zen20v2.png' +maybe chmod 0644 'openzwave/images/zooz/zen21.png' +maybe chmod 0644 'openzwave/images/zooz/zen21v3.png' +maybe chmod 0644 'openzwave/images/zooz/zen22.png' +maybe chmod 0644 'openzwave/images/zooz/zen23v3.png' +maybe chmod 0644 'openzwave/images/zooz/zen24v2.png' +maybe chmod 0644 'openzwave/images/zooz/zen26.png' +maybe chmod 0644 'openzwave/images/zooz/zen27.png' +maybe chmod 0644 'openzwave/images/zooz/zen30.png' +maybe chmod 0644 'openzwave/images/zooz/zen31.png' +maybe chmod 0644 'openzwave/images/zooz/zse09.png' +maybe chmod 0644 'openzwave/images/zooz/zse19.png' +maybe chmod 0644 'openzwave/images/zooz/zse29.png' +maybe chmod 0644 'openzwave/images/zooz/zse30.png' +maybe chmod 0644 'openzwave/images/zooz/zse33.png' +maybe chmod 0644 'openzwave/images/zooz/zse40.png' +maybe chmod 0755 'openzwave/images/zwave.me' +maybe chmod 0644 'openzwave/images/zwave.me/004001.png' +maybe chmod 0644 'openzwave/images/zwave.me/ZME_05431.png' +maybe chmod 0644 'openzwave/images/zwave.me/ZME_06433.png' +maybe chmod 0644 'openzwave/images/zwave.me/ZME_06436.png' +maybe chmod 0644 'openzwave/images/zwave.me/ZUno.png' +maybe chmod 0644 'openzwave/images/zwave.me/kfob.png' +maybe chmod 0644 'openzwave/images/zwave.me/popp_kfob-c.png' +maybe chmod 0644 'openzwave/images/zwave.me/razberry.png' +maybe chmod 0644 'openzwave/images/zwave.me/zme_raz5.png' +maybe chmod 0644 'openzwave/images/zwave.me/zweather.png' +maybe chmod 0755 'openzwave/images/zwp' +maybe chmod 0644 'openzwave/images/zwp/PA-100.png' +maybe chmod 0644 'openzwave/images/zwp/WD-100.png' +maybe chmod 0755 'openzwave/ingersoll' +maybe chmod 0644 'openzwave/ingersoll/dwzwave1.xml' +maybe chmod 0755 'openzwave/inovelli' +maybe chmod 0644 'openzwave/inovelli/lzw30-sn.xml' +maybe chmod 0644 'openzwave/inovelli/lzw30.xml' +maybe chmod 0644 'openzwave/inovelli/lzw31-sn.xml' +maybe chmod 0644 'openzwave/inovelli/lzw31.xml' +maybe chmod 0644 'openzwave/inovelli/lzw36.xml' +maybe chmod 0644 'openzwave/inovelli/lzw40.xml' +maybe chmod 0644 'openzwave/inovelli/lzw41.xml' +maybe chmod 0644 'openzwave/inovelli/lzw42.xml' +maybe chmod 0644 'openzwave/inovelli/lzw60.xml' +maybe chmod 0644 'openzwave/inovelli/nzw1201.xml' +maybe chmod 0644 'openzwave/inovelli/nzw30.xml' +maybe chmod 0644 'openzwave/inovelli/nzw31.xml' +maybe chmod 0644 'openzwave/inovelli/nzw36.xml' +maybe chmod 0644 'openzwave/inovelli/nzw37.xml' +maybe chmod 0644 'openzwave/inovelli/nzw39.xml' +maybe chmod 0644 'openzwave/inovelli/nzw96.xml' +maybe chmod 0644 'openzwave/inovelli/nzw97.xml' +maybe chmod 0644 'openzwave/inovelli/simple_module.xml' +maybe chmod 0755 'openzwave/intermatic' +maybe chmod 0644 'openzwave/intermatic/ca8900.xml' +maybe chmod 0755 'openzwave/iris' +maybe chmod 0644 'openzwave/iris/rangeextender.xml' +maybe chmod 0755 'openzwave/iwatsu' +maybe chmod 0644 'openzwave/iwatsu/ne-4ct-2p.xml' +maybe chmod 0644 'openzwave/iwatsu/ne-4ct.xml' +maybe chmod 0755 'openzwave/jasco' +maybe chmod 0644 'openzwave/jasco/45601.xml' +maybe chmod 0755 'openzwave/kaipule' +maybe chmod 0644 'openzwave/kaipule/im20.xml' +maybe chmod 0644 'openzwave/kaipule/ix32.xml' +maybe chmod 0755 'openzwave/kwikset' +maybe chmod 0644 'openzwave/kwikset/888.xml' +maybe chmod 0644 'openzwave/kwikset/910.xml' +maybe chmod 0644 'openzwave/kwikset/914c.xml' +maybe chmod 0644 'openzwave/kwikset/916.xml' +maybe chmod 0644 'openzwave/kwikset/smartcode.xml' +maybe chmod 0755 'openzwave/leviton' +maybe chmod 0644 'openzwave/leviton/dz15s.xml' +maybe chmod 0644 'openzwave/leviton/dz6hd.xml' +maybe chmod 0644 'openzwave/leviton/dzpa1.xml' +maybe chmod 0644 'openzwave/leviton/dzpd3.xml' +maybe chmod 0644 'openzwave/leviton/rzi10.xml' +maybe chmod 0644 'openzwave/leviton/vrcpg.xml' +maybe chmod 0644 'openzwave/leviton/vrcs2.xml' +maybe chmod 0644 'openzwave/leviton/vrcz4.xml' +maybe chmod 0644 'openzwave/leviton/vre06.xml' +maybe chmod 0644 'openzwave/leviton/vrf01.xml' +maybe chmod 0644 'openzwave/leviton/vri06.xml' +maybe chmod 0644 'openzwave/leviton/vri10.xml' +maybe chmod 0644 'openzwave/leviton/vrpa1.xml' +maybe chmod 0644 'openzwave/leviton/vrpd3.xml' +maybe chmod 0644 'openzwave/leviton/vrs15.xml' +maybe chmod 0644 'openzwave/leviton/zw4sf.xml' +maybe chmod 0755 'openzwave/linear' +maybe chmod 0644 'openzwave/linear/GC-TBZ48.xml' +maybe chmod 0644 'openzwave/linear/LB60Z-1.xml' +maybe chmod 0644 'openzwave/linear/PD300Z-2.xml' +maybe chmod 0644 'openzwave/linear/WA00Z-1.xml' +maybe chmod 0644 'openzwave/linear/WA105DBZ-1.xml' +maybe chmod 0644 'openzwave/linear/WADWAZ-1.xml' +maybe chmod 0644 'openzwave/linear/WAPIRZ-1.xml' +maybe chmod 0644 'openzwave/linear/WD500Z-1.xml' +maybe chmod 0644 'openzwave/linear/WD500Z5-1.xml' +maybe chmod 0644 'openzwave/linear/WS15Z-1.xml' +maybe chmod 0644 'openzwave/linear/WT00Z-1.xml' +maybe chmod 0644 'openzwave/linear/WT00Z5-1.xml' +maybe chmod 0644 'openzwave/linear/gd00z-7.xml' +maybe chmod 0644 'openzwave/linear/ngd00z.xml' +maybe chmod 0755 'openzwave/logicsoft' +maybe chmod 0644 'openzwave/logicsoft/ZDB5100.xml' +maybe chmod 0644 'openzwave/logicsoft/ZHC5002.xml' +maybe chmod 0644 'openzwave/logicsoft/ZHC5010.xml' +maybe chmod 0644 'openzwave/manufacturer_specific.xml' +maybe chmod 0644 'openzwave/manufacturer_specific.xsd' +maybe chmod 0755 'openzwave/mcohome' +maybe chmod 0644 'openzwave/mcohome/a8-9.xml' +maybe chmod 0644 'openzwave/mcohome/mh7h.xml' +maybe chmod 0644 'openzwave/mcohome/mh8fceu.xml' +maybe chmod 0755 'openzwave/mcohome/mh8fceu0803.xml' +maybe chmod 0644 'openzwave/mcohome/mh9co2.xml' +maybe chmod 0644 'openzwave/mcohome/mhp210.xml' +maybe chmod 0644 'openzwave/mcohome/mhp220.xml' +maybe chmod 0644 'openzwave/mcohome/mhp511.xml' +maybe chmod 0644 'openzwave/mcohome/mhs311.xml' +maybe chmod 0644 'openzwave/mcohome/mhs312.xml' +maybe chmod 0644 'openzwave/mcohome/mhs314.xml' +maybe chmod 0644 'openzwave/mcohome/mhs411.xml' +maybe chmod 0644 'openzwave/mcohome/mhs412.xml' +maybe chmod 0644 'openzwave/mcohome/mhs513.xml' +maybe chmod 0755 'openzwave/merten' +maybe chmod 0644 'openzwave/merten/5044xx.xml' +maybe chmod 0644 'openzwave/merten/5046xx.xml' +maybe chmod 0644 'openzwave/merten/506004.xml' +maybe chmod 0644 'openzwave/merten/507801.xml' +maybe chmod 0644 'openzwave/merten/508244.xml' +maybe chmod 0644 'openzwave/merten/50x5xx.xml' +maybe chmod 0755 'openzwave/miyakawaelectric' +maybe chmod 0644 'openzwave/miyakawaelectric/me-d101.xml' +maybe chmod 0755 'openzwave/namron' +maybe chmod 0644 'openzwave/namron/1402756.xml' +maybe chmod 0755 'openzwave/nexia' +maybe chmod 0644 'openzwave/nexia/db100z.xml' +maybe chmod 0644 'openzwave/nexia/th100nx.xml' +maybe chmod 0755 'openzwave/nodon' +maybe chmod 0644 'openzwave/nodon/asp3100SmartPlug.xml' +maybe chmod 0644 'openzwave/nodon/crc3100OctanRemote.xml' +maybe chmod 0644 'openzwave/nodon/crc360xSofremote.xml' +maybe chmod 0644 'openzwave/nodon/cws3101wallswitch.xml' +maybe chmod 0644 'openzwave/nodon/msp31xxMicroSmartPlug.xml' +maybe chmod 0755 'openzwave/northq' +maybe chmod 0644 'openzwave/northq/nq9021.xml' +maybe chmod 0644 'openzwave/northq/nq9121.xml' +maybe chmod 0644 'openzwave/northq/nq92021.xml' +maybe chmod 0755 'openzwave/oomi' +maybe chmod 0644 'openzwave/oomi/ft100.xml' +maybe chmod 0644 'openzwave/oomi/ft111.xml' +maybe chmod 0644 'openzwave/oomi/ft112.xml' +maybe chmod 0644 'openzwave/oomi/ft118.xml' +maybe chmod 0644 'openzwave/options.xml' +maybe chmod 0644 'openzwave/options.xsd' +maybe chmod 0755 'openzwave/permundo' +maybe chmod 0644 'openzwave/permundo/psc132zw.xml' +maybe chmod 0644 'openzwave/permundo/psc234zw.xml' +maybe chmod 0755 'openzwave/philio' +maybe chmod 0644 'openzwave/philio/pad02.xml' +maybe chmod 0644 'openzwave/philio/pan03.xml' +maybe chmod 0644 'openzwave/philio/pan04.xml' +maybe chmod 0644 'openzwave/philio/pan05.xml' +maybe chmod 0644 'openzwave/philio/pan06.xml' +maybe chmod 0644 'openzwave/philio/pan07.xml' +maybe chmod 0644 'openzwave/philio/pan08.xml' +maybe chmod 0644 'openzwave/philio/pan11-1.xml' +maybe chmod 0644 'openzwave/philio/pan11.xml' +maybe chmod 0644 'openzwave/philio/pan16.xml' +maybe chmod 0644 'openzwave/philio/phpab01.xml' +maybe chmod 0644 'openzwave/philio/phpat02.xml' +maybe chmod 0644 'openzwave/philio/phpsg01.xml' +maybe chmod 0644 'openzwave/philio/pse02.xml' +maybe chmod 0644 'openzwave/philio/psm02.xml' +maybe chmod 0644 'openzwave/philio/psp05.xml' +maybe chmod 0644 'openzwave/philio/psr03-1b.xml' +maybe chmod 0644 'openzwave/philio/psr04.xml' +maybe chmod 0644 'openzwave/philio/pst02-1c.xml' +maybe chmod 0644 'openzwave/philio/pst02-b.xml' +maybe chmod 0644 'openzwave/philio/pst02.xml' +maybe chmod 0755 'openzwave/polycontrol' +maybe chmod 0644 'openzwave/polycontrol/doorlock.xml' +maybe chmod 0644 'openzwave/polycontrol/doorlockv3.xml' +maybe chmod 0644 'openzwave/polycontrol/keypad.xml' +maybe chmod 0644 'openzwave/polycontrol/polylock.xml' +maybe chmod 0755 'openzwave/popp' +maybe chmod 0644 'openzwave/popp/004407.xml' +maybe chmod 0644 'openzwave/popp/009105.xml' +maybe chmod 0644 'openzwave/popp/009303.xml' +maybe chmod 0644 'openzwave/popp/009402.xml' +maybe chmod 0644 'openzwave/popp/009501.xml' +maybe chmod 0644 'openzwave/popp/012501.xml' +maybe chmod 0644 'openzwave/popp/123580.xml' +maybe chmod 0644 'openzwave/popp/123601.xml' +maybe chmod 0644 'openzwave/popp/123658.xml' +maybe chmod 0644 'openzwave/popp/700045.xml' +maybe chmod 0644 'openzwave/popp/700168.xml' +maybe chmod 0644 'openzwave/popp/700342.xml' +maybe chmod 0644 'openzwave/popp/700397.xml' +maybe chmod 0644 'openzwave/popp/700793.xml' +maybe chmod 0644 'openzwave/popp/701202.xml' +maybe chmod 0644 'openzwave/popp/dwt.xml' +maybe chmod 0644 'openzwave/popp/smoke-detector.xml' +maybe chmod 0644 'openzwave/popp/solar-siren.xml' +maybe chmod 0644 'openzwave/popp/zweather.xml' +maybe chmod 0755 'openzwave/prowell' +maybe chmod 0644 'openzwave/prowell/zw-702.xml' +maybe chmod 0755 'openzwave/q-light' +maybe chmod 0644 'openzwave/q-light/q-light_puck.xml' +maybe chmod 0644 'openzwave/q-light/q-light_zerodim.xml' +maybe chmod 0644 'openzwave/q-light/q-light_zerodim_2pol.xml' +maybe chmod 0755 'openzwave/qees' +maybe chmod 0644 'openzwave/qees/reto-dimmer-plus.xml' +maybe chmod 0644 'openzwave/qees/reto-plugin-switch.xml' +maybe chmod 0755 'openzwave/qubino' +maybe chmod 0644 'openzwave/qubino/ZMNHAA2.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHADx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHBA2.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHBDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHCA2.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHCDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHDA2.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHDDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHHDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHIA2.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHIDxS1.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHIDxS2.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHJA2.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHJD1.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHKDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHLAx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHLDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHNDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHODx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHQDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHSDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHTDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHTDxS3.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHUD1.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHVDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHWD1.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHXDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHYDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNHZDx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNKADx.xml' +maybe chmod 0644 'openzwave/qubino/ZMNKIDx.xml' +maybe chmod 0755 'openzwave/quby' +maybe chmod 0644 'openzwave/quby/qb2.xml' +maybe chmod 0755 'openzwave/rcs' +maybe chmod 0644 'openzwave/rcs/em52-zw.xml' +maybe chmod 0644 'openzwave/rcs/pm12-zw.xml' +maybe chmod 0644 'openzwave/rcs/therm0005.xml' +maybe chmod 0644 'openzwave/rcs/therm0007.xml' +maybe chmod 0644 'openzwave/rcs/therm0009.xml' +maybe chmod 0755 'openzwave/remotec' +maybe chmod 0644 'openzwave/remotec/bw8120eu.xml' +maybe chmod 0644 'openzwave/remotec/zfm-80.xml' +maybe chmod 0644 'openzwave/remotec/zrc-100eu.xml' +maybe chmod 0644 'openzwave/remotec/zrc-90.xml' +maybe chmod 0644 'openzwave/remotec/zts-110.xml' +maybe chmod 0644 'openzwave/remotec/zts-500.xml' +maybe chmod 0644 'openzwave/remotec/zurc.xml' +maybe chmod 0644 'openzwave/remotec/zxt-120.xml' +maybe chmod 0644 'openzwave/remotec/zxt-310.xml' +maybe chmod 0644 'openzwave/remotec/zxt-600.xml' +maybe chmod 0755 'openzwave/ring' +maybe chmod 0644 'openzwave/ring/PIR-SS.xml' +maybe chmod 0755 'openzwave/schlage' +maybe chmod 0644 'openzwave/schlage/BE468.xml' +maybe chmod 0644 'openzwave/schlage/BE468ZP.xml' +maybe chmod 0644 'openzwave/schlage/BE469.xml' +maybe chmod 0644 'openzwave/schlage/BE469ZP.xml' +maybe chmod 0644 'openzwave/schlage/fe599.xml' +maybe chmod 0755 'openzwave/schlagelink' +maybe chmod 0644 'openzwave/schlagelink/41.xml' +maybe chmod 0644 'openzwave/schlagelink/itemp.xml' +maybe chmod 0644 'openzwave/schlagelink/minikeypad.xml' +maybe chmod 0755 'openzwave/sensative' +maybe chmod 0644 'openzwave/sensative/strips.xml' +maybe chmod 0644 'openzwave/sensative/stripscomfort.xml' +maybe chmod 0755 'openzwave/sercomm' +maybe chmod 0644 'openzwave/sercomm/sw-clp01-eu.xml' +maybe chmod 0755 'openzwave/shenzen_neo' +maybe chmod 0644 'openzwave/shenzen_neo/ls01ch.xml' +maybe chmod 0644 'openzwave/shenzen_neo/ls02ch.xml' +maybe chmod 0644 'openzwave/shenzen_neo/ls03ch.xml' +maybe chmod 0644 'openzwave/shenzen_neo/nas-ab01z.xml' +maybe chmod 0644 'openzwave/shenzen_neo/nas-ds01z.xml' +maybe chmod 0644 'openzwave/shenzen_neo/nas-pd01z.xml' +maybe chmod 0644 'openzwave/shenzen_neo/nas-pd02z.xml' +maybe chmod 0644 'openzwave/shenzen_neo/nas-pd03z.xml' +maybe chmod 0644 'openzwave/shenzen_neo/nas-rc01z.xml' +maybe chmod 0644 'openzwave/shenzen_neo/nas-wr01z.xml' +maybe chmod 0644 'openzwave/shenzen_neo/nas-wr01ze.xml' +maybe chmod 0644 'openzwave/shenzen_neo/nas-ws02z.xml' +maybe chmod 0755 'openzwave/shenzen_saykey' +maybe chmod 0644 'openzwave/shenzen_saykey/sk-3007-05.xml' +maybe chmod 0755 'openzwave/simon' +maybe chmod 0644 'openzwave/simon/10002034-13X.xml' +maybe chmod 0644 'openzwave/simon/10002041-13X.xml' +maybe chmod 0755 'openzwave/simon/10002080-13X.xml' +maybe chmod 0755 'openzwave/smartthings' +maybe chmod 0644 'openzwave/smartthings/pgc401m.xml' +maybe chmod 0644 'openzwave/smartthings/sth-eth200.xml' +maybe chmod 0755 'openzwave/somfy' +maybe chmod 0644 'openzwave/somfy/1811265_ZRTSI.xml' +maybe chmod 0755 'openzwave/steinel' +maybe chmod 0644 'openzwave/steinel/is140-2.xml' +maybe chmod 0644 'openzwave/steinel/l810-led-ihf.xml' +maybe chmod 0644 'openzwave/steinel/rs-led-d2.xml' +maybe chmod 0644 'openzwave/steinel/xled-home-2.xml' +maybe chmod 0755 'openzwave/stelpro' +maybe chmod 0644 'openzwave/stelpro/stzw402.xml' +maybe chmod 0755 'openzwave/sunricher' +maybe chmod 0644 'openzwave/sunricher/srzv9001k12dimz4.xml' +maybe chmod 0644 'openzwave/sunricher/srzv9001k12dimz5.xml' +maybe chmod 0644 'openzwave/sunricher/srzv9001k8.xml' +maybe chmod 0644 'openzwave/sunricher/srzv9001t4dimeu.xml' +maybe chmod 0644 'openzwave/sunricher/srzv9001tccteu.xml' +maybe chmod 0644 'openzwave/sunricher/srzv9003t4rgbweu.xml' +maybe chmod 0644 'openzwave/sunricher/srzv9101sachpeu.xml' +maybe chmod 0644 'openzwave/sunricher/zv2835rac.xml' +maybe chmod 0644 'openzwave/sunricher/zv9101.xml' +maybe chmod 0644 'openzwave/sunricher/zv9101fa.xml' +maybe chmod 0755 'openzwave/swiid' +maybe chmod 0644 'openzwave/swiid/swiidinter.xml' +maybe chmod 0644 'openzwave/swiid/swiidplug.xml' +maybe chmod 0755 'openzwave/technisat' +maybe chmod 0644 'openzwave/technisat/03009496.xml' +maybe chmod 0644 'openzwave/technisat/03009497.xml' +maybe chmod 0644 'openzwave/technisat/03009499.xml' +maybe chmod 0755 'openzwave/telldus' +maybe chmod 0644 'openzwave/telldus/tzdw100.xml' +maybe chmod 0644 'openzwave/telldus/tzwp100.xml' +maybe chmod 0644 'openzwave/telldus/tzwp102.xml' +maybe chmod 0755 'openzwave/there' +maybe chmod 0644 'openzwave/there/800z.xml' +maybe chmod 0755 'openzwave/thermofloor' +maybe chmod 0644 'openzwave/thermofloor/heatit-zdim.xml' +maybe chmod 0644 'openzwave/thermofloor/heatit021.xml' +maybe chmod 0644 'openzwave/thermofloor/heatit056.xml' +maybe chmod 0644 'openzwave/thermofloor/heatit058.xml' +maybe chmod 0644 'openzwave/thermofloor/heatit20a.xml' +maybe chmod 0644 'openzwave/thermofloor/heatitz8.xml' +maybe chmod 0755 'openzwave/trane' +maybe chmod 0644 'openzwave/trane/TZEMT400AB32MAA.xml' +maybe chmod 0644 'openzwave/trane/TZEMT400BB32MAA.xml' +maybe chmod 0644 'openzwave/trane/TZEMT524AA21MA.xml' +maybe chmod 0755 'openzwave/vera' +maybe chmod 0644 'openzwave/vera/vera2.xml' +maybe chmod 0755 'openzwave/vision' +maybe chmod 0644 'openzwave/vision/1701.xml' +maybe chmod 0644 'openzwave/vision/brg1-433.xml' +maybe chmod 0644 'openzwave/vision/zd2102.xml' +maybe chmod 0644 'openzwave/vision/zd2105us5.xml' +maybe chmod 0644 'openzwave/vision/zd2201.xml' +maybe chmod 0644 'openzwave/vision/zd2301.xml' +maybe chmod 0644 'openzwave/vision/zf5201.xml' +maybe chmod 0644 'openzwave/vision/zg8101.xml' +maybe chmod 0644 'openzwave/vision/zl7101us.xml' +maybe chmod 0644 'openzwave/vision/zl7201us.xml' +maybe chmod 0644 'openzwave/vision/zl7261.xml' +maybe chmod 0644 'openzwave/vision/zl7431.xml' +maybe chmod 0644 'openzwave/vision/zl7432us.xml' +maybe chmod 0644 'openzwave/vision/zm1601eu.xml' +maybe chmod 0644 'openzwave/vision/zm1601eu5.xml' +maybe chmod 0644 'openzwave/vision/zm1602eu.xml' +maybe chmod 0644 'openzwave/vision/zm1602eu5.xml' +maybe chmod 0644 'openzwave/vision/zp3102.xml' +maybe chmod 0644 'openzwave/vision/zp3111.xml' +maybe chmod 0644 'openzwave/vision/zr1202us.xml' +maybe chmod 0644 'openzwave/vision/zs5101eu.xml' +maybe chmod 0644 'openzwave/vision/zs610eu.xml' +maybe chmod 0644 'openzwave/vision/zu1401jp.xml' +maybe chmod 0755 'openzwave/vitrum' +maybe chmod 0644 'openzwave/vitrum/vitrumI-Dimmer.xml' +maybe chmod 0644 'openzwave/vitrum/vitrumI-Switch.xml' +maybe chmod 0644 'openzwave/vitrum/vitrumII-Dimmer.xml' +maybe chmod 0644 'openzwave/vitrum/vitrumII-RollerBlind.xml' +maybe chmod 0644 'openzwave/vitrum/vitrumII-Switch.xml' +maybe chmod 0644 'openzwave/vitrum/vitrumIII-Dimmer.xml' +maybe chmod 0644 'openzwave/vitrum/vitrumIII-Switch.xml' +maybe chmod 0644 'openzwave/vitrum/vitrumIV-Switch.xml' +maybe chmod 0644 'openzwave/vitrum/vitrumVI-Switch.xml' +maybe chmod 0755 'openzwave/waynedalton' +maybe chmod 0644 'openzwave/waynedalton/WDTC-20.xml' +maybe chmod 0755 'openzwave/wenzhou' +maybe chmod 0644 'openzwave/wenzhou/sm103.xml' +maybe chmod 0644 'openzwave/wenzhou/tsp01.xml' +maybe chmod 0644 'openzwave/wenzhou/tz55.xml' +maybe chmod 0644 'openzwave/wenzhou/tz56.xml' +maybe chmod 0644 'openzwave/wenzhou/tz56s.xml' +maybe chmod 0644 'openzwave/wenzhou/tz57.xml' +maybe chmod 0644 'openzwave/wenzhou/tz65d.xml' +maybe chmod 0644 'openzwave/wenzhou/tz66d.xml' +maybe chmod 0644 'openzwave/wenzhou/tz67.xml' +maybe chmod 0644 'openzwave/wenzhou/tz68.xml' +maybe chmod 0644 'openzwave/wenzhou/tz69.xml' +maybe chmod 0644 'openzwave/wenzhou/tz74.xml' +maybe chmod 0644 'openzwave/wenzhou/tz78.xml' +maybe chmod 0644 'openzwave/wenzhou/tz79.xml' +maybe chmod 0644 'openzwave/wenzhou/tz88.xml' +maybe chmod 0755 'openzwave/widom' +maybe chmod 0644 'openzwave/widom/DRY.xml' +maybe chmod 0644 'openzwave/widom/UBS104.xml' +maybe chmod 0644 'openzwave/widom/UME304C_S.xml' +maybe chmod 0644 'openzwave/widom/UMS2.xml' +maybe chmod 0644 'openzwave/widom/WDS.xml' +maybe chmod 0644 'openzwave/widom/WDS2.xml' +maybe chmod 0644 'openzwave/widom/WSP.xml' +maybe chmod 0644 'openzwave/widom/WTED.xml' +maybe chmod 0755 'openzwave/wink' +maybe chmod 0644 'openzwave/wink/wnk-mot1.xml' +maybe chmod 0644 'openzwave/wink/wnk-sir1p.xml' +maybe chmod 0755 'openzwave/zipato' +maybe chmod 0644 'openzwave/zipato/MiniKeypad.xml' +maybe chmod 0644 'openzwave/zipato/RGBBulb.xml' +maybe chmod 0644 'openzwave/zipato/RGBBulb2.xml' +maybe chmod 0644 'openzwave/zipato/ne-nas-ab02z.xml' +maybe chmod 0644 'openzwave/zipato/pan04.xml' +maybe chmod 0644 'openzwave/zipato/vszd2102.xml' +maybe chmod 0644 'openzwave/zipato/zp3102.xml' +maybe chmod 0755 'openzwave/zooz' +maybe chmod 0644 'openzwave/zooz/zen06.xml' +maybe chmod 0644 'openzwave/zooz/zen07.xml' +maybe chmod 0644 'openzwave/zooz/zen15.xml' +maybe chmod 0644 'openzwave/zooz/zen16.xml' +maybe chmod 0644 'openzwave/zooz/zen20.xml' +maybe chmod 0644 'openzwave/zooz/zen20v2.xml' +maybe chmod 0644 'openzwave/zooz/zen21.xml' +maybe chmod 0644 'openzwave/zooz/zen21v3.xml' +maybe chmod 0644 'openzwave/zooz/zen22.xml' +maybe chmod 0644 'openzwave/zooz/zen22v2.xml' +maybe chmod 0644 'openzwave/zooz/zen23.xml' +maybe chmod 0644 'openzwave/zooz/zen23v3.xml' +maybe chmod 0644 'openzwave/zooz/zen24.xml' +maybe chmod 0644 'openzwave/zooz/zen24v2.xml' +maybe chmod 0644 'openzwave/zooz/zen25.xml' +maybe chmod 0644 'openzwave/zooz/zen26.xml' +maybe chmod 0644 'openzwave/zooz/zen27.xml' +maybe chmod 0644 'openzwave/zooz/zen30.xml' +maybe chmod 0644 'openzwave/zooz/zen31.xml' +maybe chmod 0644 'openzwave/zooz/zse08.xml' +maybe chmod 0644 'openzwave/zooz/zse09.xml' +maybe chmod 0644 'openzwave/zooz/zse18.xml' +maybe chmod 0644 'openzwave/zooz/zse19.xml' +maybe chmod 0644 'openzwave/zooz/zse29.xml' +maybe chmod 0644 'openzwave/zooz/zse30.xml' +maybe chmod 0644 'openzwave/zooz/zse33.xml' +maybe chmod 0644 'openzwave/zooz/zse40.xml' +maybe chmod 0755 'openzwave/zwave.me' +maybe chmod 0644 'openzwave/zwave.me/004001.xml' +maybe chmod 0644 'openzwave/zwave.me/ZME_05431.xml' +maybe chmod 0644 'openzwave/zwave.me/ZME_05461.xml' +maybe chmod 0644 'openzwave/zwave.me/ZME_06433.xml' +maybe chmod 0644 'openzwave/zwave.me/ZME_06436.xml' +maybe chmod 0644 'openzwave/zwave.me/ZME_064381.xml' +maybe chmod 0644 'openzwave/zwave.me/ZME_064435.xml' +maybe chmod 0644 'openzwave/zwave.me/ZME_KFOB-S.xml' +maybe chmod 0644 'openzwave/zwave.me/ZME_RC2.xml' +maybe chmod 0644 'openzwave/zwave.me/ZME_WALLC-S.xml' +maybe chmod 0644 'openzwave/zwave.me/ZME_WCD2.xml' +maybe chmod 0644 'openzwave/zwave.me/ZUno.xml' +maybe chmod 0644 'openzwave/zwave.me/iTemp.xml' +maybe chmod 0644 'openzwave/zwave.me/kfob.xml' +maybe chmod 0644 'openzwave/zwave.me/popp_kfob-c.xml' +maybe chmod 0644 'openzwave/zwave.me/razberry.xml' +maybe chmod 0644 'openzwave/zwave.me/zme_raz5.xml' +maybe chmod 0644 'openzwave/zwave.me/zweather.xml' +maybe chmod 0644 'openzwave/zwcfg.xsd' +maybe chmod 0755 'openzwave/zwp' +maybe chmod 0644 'openzwave/zwp/PA-100.xml' +maybe chmod 0644 'openzwave/zwp/WD-100.xml' +maybe chmod 0644 'openzwave/zwscene.xsd' maybe chmod 0755 'opt' maybe chmod 0644 'pam.conf' maybe chmod 0755 'pam.d' @@ -987,6 +2671,7 @@ maybe chmod 0644 'pam.d/newusers' maybe chmod 0644 'pam.d/other' maybe chmod 0644 'pam.d/passwd' maybe chmod 0644 'pam.d/polkit-1' +maybe chmod 0644 'pam.d/ppp' maybe chmod 0644 'pam.d/runuser' maybe chmod 0644 'pam.d/runuser-l' maybe chmod 0644 'pam.d/sshd' @@ -1132,11 +2817,28 @@ maybe chown 'postgres' 'postgresql/11/main/start.conf' maybe chgrp 'postgres' 'postgresql/11/main/start.conf' maybe chmod 0644 'postgresql/11/main/start.conf' maybe chmod 0755 'ppp' +maybe chmod 0600 'ppp/chap-secrets' +maybe chmod 0755 'ppp/ip-down' maybe chmod 0755 'ppp/ip-down.d' +maybe chmod 0755 'ppp/ip-down.d/0000usepeerdns' maybe chmod 0755 'ppp/ip-down.d/000resolvconf' +maybe chmod 0755 'ppp/ip-pre-up' +maybe chmod 0755 'ppp/ip-pre-up.d' +maybe chmod 0755 'ppp/ip-up' maybe chmod 0755 'ppp/ip-up.d' +maybe chmod 0755 'ppp/ip-up.d/0000usepeerdns' maybe chmod 0755 'ppp/ip-up.d/000resolvconf' maybe chmod 0755 'ppp/ip-up.d/exim4' +maybe chmod 0755 'ppp/ipv6-down' +maybe chmod 0755 'ppp/ipv6-down.d' +maybe chmod 0755 'ppp/ipv6-up' +maybe chmod 0755 'ppp/ipv6-up.d' +maybe chmod 0644 'ppp/options' +maybe chmod 0600 'ppp/pap-secrets' +maybe chgrp 'dip' 'ppp/peers' +maybe chmod 2750 'ppp/peers' +maybe chgrp 'dip' 'ppp/peers/provider' +maybe chmod 0640 'ppp/peers/provider' maybe chmod 0770 'prelink.conf.d' maybe chmod 0644 'prelink.conf.d/cmk-update-agent.conf' maybe chmod 0644 'profile' @@ -1375,6 +3077,10 @@ maybe chmod 0755 'usb_modeswitch.d' maybe chmod 0755 'vim' maybe chmod 0644 'vim/vimrc' maybe chmod 0644 'vim/vimrc.tiny' +maybe chmod 0755 'vulkan' +maybe chmod 0755 'vulkan/explicit_layer.d' +maybe chmod 0755 'vulkan/icd.d' +maybe chmod 0755 'vulkan/implicit_layer.d' maybe chmod 0644 'wgetrc' maybe chmod 0700 'wireguard' maybe chmod 0755 'wireguard/configs' @@ -1413,6 +3119,7 @@ maybe chmod 0644 'wpa_supplicant/wpa_supplicant.conf' maybe chmod 0644 'xattr.conf' maybe chmod 0755 'xdg' maybe chmod 0755 'xdg/autostart' +maybe chmod 0644 'xdg/autostart/at-spi-dbus-bus.desktop' maybe chmod 0644 'xdg/autostart/xdg-user-dirs.desktop' maybe chmod 0755 'xdg/systemd' maybe chmod 0644 'xdg/user-dirs.conf' diff --git a/NetworkManager/NetworkManager.conf b/NetworkManager/NetworkManager.conf new file mode 100644 index 00000000..d8b33d91 --- /dev/null +++ b/NetworkManager/NetworkManager.conf @@ -0,0 +1,5 @@ +[main] +plugins=ifupdown,keyfile + +[ifupdown] +managed=false diff --git a/NetworkManager/dispatcher.d/01-ifupdown b/NetworkManager/dispatcher.d/01-ifupdown new file mode 100755 index 00000000..5ac31f07 --- /dev/null +++ b/NetworkManager/dispatcher.d/01-ifupdown @@ -0,0 +1,82 @@ +#!/bin/sh -e +# Script to dispatch NetworkManager events +# +# Runs ifupdown scripts when NetworkManager fiddles with interfaces. +# See NetworkManager(8) for further documentation of the dispatcher events. + +# We do not handle connectivity-change events in ifupdown so simply exit at +# this point +if [ "$2" = "connectivity-change" ]; then + exit 0; +fi + +if [ -z "$1" ]; then + echo "$0: called with no interface" 1>&2 + exit 1; +fi + +if [ -n "$IP4_NUM_ADDRESSES" ] && [ "$IP4_NUM_ADDRESSES" -gt 0 ]; then + ADDRESS_FAMILIES="$ADDRESS_FAMILIES inet" +fi +if [ -n "$IP6_NUM_ADDRESSES" ] && [ "$IP6_NUM_ADDRESSES" -gt 0 ]; then + ADDRESS_FAMILIES="$ADDRESS_FAMILIES inet6" +fi + +# If we have a VPN connection ignore the underlying IP address(es) +if [ "$2" = "vpn-up" ] || [ "$2" = "vpn-down" ]; then + ADDRESS_FAMILIES="" +fi + +if [ -n "$VPN_IP4_NUM_ADDRESSES" ] && [ "$VPN_IP4_NUM_ADDRESSES" -gt 0 ]; then + ADDRESS_FAMILIES="$ADDRESS_FAMILIES inet" +fi +if [ -n "$VPN_IP6_NUM_ADDRESSES" ] && [ "$VPN_IP6_NUM_ADDRESSES" -gt 0 ]; then + ADDRESS_FAMILIES="$ADDRESS_FAMILIES inet6" +fi + +# We're probably bringing the interface down. +[ -n "$ADDRESS_FAMILIES" ] || ADDRESS_FAMILIES="inet" + +# Fake ifupdown environment +export IFACE="$1" +export LOGICAL="$1" +export METHOD="NetworkManager" +export VERBOSITY="0" + +for i in $ADDRESS_FAMILIES; do + + export ADDRFAM="$i" + + # Run the right scripts + case "$2" in + up|vpn-up) + export MODE="start" + export PHASE="post-up" + run-parts /etc/network/if-up.d + ;; + down|vpn-down) + export MODE="stop" + export PHASE="post-down" + run-parts /etc/network/if-post-down.d + ;; +# pre-up/pre-down not implemented. See +# https://bugzilla.gnome.org/show_bug.cgi?id=387832 +# pre-up) +# export MODE="start" +# export PHASE="pre-up" +# run-parts /etc/network/if-pre-up.d +# ;; +# pre-down) +# export MODE="stop" +# export PHASE="pre-down" +# run-parts /etc/network/if-down.d +# ;; + hostname|dhcp4-change|dhcp6-change) + # Do nothing + ;; + *) + echo "$0: called with unknown action \`$2'" 1>&2 + exit 1 + ;; + esac +done diff --git a/PackageKit/PackageKit.conf b/PackageKit/PackageKit.conf new file mode 100644 index 00000000..41b487be --- /dev/null +++ b/PackageKit/PackageKit.conf @@ -0,0 +1,21 @@ +# Only the system administrator should modify this file, ordinary users +# should not have to change anything. + +[Daemon] + +# Default backends, as chosen in the configure script. This will be used +# where no --backend="foo" option is given to the daemon. +# +# The order they are specified is the order they are tried, so for the +# value "foo,bar" first "foo" will be attempted and then "bar" if the +# libpk_backend_foo.so module load failed. +#DefaultBackend=auto + +# Unlock the backend after this many seconds idle. +#BackendShutdownTimeout=5 + +# Shut down the daemon after this many seconds idle. 0 means don't shutdown. +#ShutdownTimeout=300 + +# Keep the packages after they have been downloaded +#KeepCache=false diff --git a/PackageKit/Vendor.conf b/PackageKit/Vendor.conf new file mode 100644 index 00000000..345a1752 --- /dev/null +++ b/PackageKit/Vendor.conf @@ -0,0 +1,48 @@ +# Only the system vendor should modify this file, ordinary users +# should not have to change anything. + +[PackagesNotFound] + +# This is a link to a vendor URL which is shown when a suitable package +# could not be found in any remote software repository. +# The page set here should explain how to add new software repositories if required. +# +# If the value is set to 'none' then no link is shown. +# +# default=http://www.packagekit.org/pk-package-not-found.html +DefaultUrl=https://wiki.debian.org/PackageKit/ItemNotFound#Missing_Package + +# The URL which is shown to the user when a codec could not be found. +# It should explain why certain codecs cannot be used, and perhaps show +# links to web stores where the codec can be legally purchased. +# +# If the value is set to 'none' then the value of DefaultUrl is used. +# +# default=none +CodecUrl=https://wiki.debian.org/PackageKit/ItemNotFound#Missing_Codec + +# The URL which is shown to the user when hardware drivers could not be found. +# It should explain why some hardware is not supported, and links to futher +# information. +# +# If the value is set to 'none' then the value of DefaultUrl is used. +# +# default=none +HardwareUrl=https://wiki.debian.org/PackageKit/ItemNotFound#Missing_Driver + +# The URL which is shown to the user when fonts could not be found. +# Alternatives should probably be suggested where possible. +# +# If the value is set to 'none' then the value of DefaultUrl is used. +# +# default=none +FontUrl=https://wiki.debian.org/PackageKit/ItemNotFound#Missing_Font + +# The URL which is shown to the user when programs handing a mime tpye could not +# be found. It should probably explain how to use wine if the program is a +# Windows program, or suggest alternatives. +# +# If the value is set to 'none' then the value of DefaultUrl is used. +# +# default=none +MimeUrl=https://wiki.debian.org/PackageKit/ItemNotFound#Missing_MIME_Support diff --git a/X11/Xsession b/X11/Xsession index 6ad7d6ed..a38a4688 100755 --- a/X11/Xsession +++ b/X11/Xsession @@ -60,6 +60,24 @@ USERXSESSIONRC=$HOME/.xsessionrc ALTUSERXSESSION=$HOME/.Xsession ERRFILE=$HOME/.xsession-errors +OPTIONS="$( + if [ -r "$OPTIONFILE" ]; then + cat "$OPTIONFILE" + fi + if [ -d /etc/X11/Xsession.options.d ]; then + run-parts --list --regex '\.conf$' /etc/X11/Xsession.options.d | xargs -d '\n' cat + fi +)" + +has_option() { + # Ensure that a later no-foo overrides an earlier foo + if [ "$(echo "$OPTIONS" | grep -Eo "^(no-)?$1\>" | tail -n 1)" = "$1" ]; then + return 0 + else + return 1 + fi +} + # attempt to create an error file; abort if we cannot if (umask 077 && touch "$ERRFILE") 2> /dev/null && [ -w "$ERRFILE" ] && [ ! -L "$ERRFILE" ]; then diff --git a/X11/Xsession.d/20x11-common_process-args b/X11/Xsession.d/20x11-common_process-args index 93e46538..c58e777c 100644 --- a/X11/Xsession.d/20x11-common_process-args +++ b/X11/Xsession.d/20x11-common_process-args @@ -2,18 +2,6 @@ # This file is sourced by Xsession(5), not executed. -# read OPTIONFILE -OPTIONS=$(cat "$OPTIONFILE") || true - -has_option() { - if [ "${OPTIONS#* -$1}" != "$OPTIONS" ]; then - return 0 - else - return 1 - fi -} - # Determine how many arguments were provided. case $# in 0) @@ -45,7 +33,7 @@ case $# in ;; *) # Specific program was requested. - STARTUP_FULL_PATH=$(/usr/bin/which "$1" || true) + STARTUP_FULL_PATH=$(/usr/bin/which "${1%% *}" || true) if [ -n "$STARTUP_FULL_PATH" ] && [ -e "$STARTUP_FULL_PATH" ]; then if [ -x "$STARTUP_FULL_PATH" ]; then STARTUP="$1" diff --git a/X11/Xsession.d/90qt-a11y b/X11/Xsession.d/90qt-a11y new file mode 100644 index 00000000..bd3d1fb6 --- /dev/null +++ b/X11/Xsession.d/90qt-a11y @@ -0,0 +1,12 @@ +# -*- sh -*- +# Xsession.d script to set the env variables to enable accessibility for Qt +# +# This file is sourced by Xsession(5), not executed. + +QT_ACCESSIBILITY=1 + +export QT_ACCESSIBILITY + +if [ -x "/usr/bin/dbus-update-activation-environment" ]; then + dbus-update-activation-environment --verbose --systemd QT_ACCESSIBILITY +fi diff --git a/alternatives/libblas.so.3-arm-linux-gnueabihf b/alternatives/libblas.so.3-arm-linux-gnueabihf new file mode 120000 index 00000000..34f7de38 --- /dev/null +++ b/alternatives/libblas.so.3-arm-linux-gnueabihf @@ -0,0 +1 @@ +/usr/lib/arm-linux-gnueabihf/blas/libblas.so.3 \ No newline at end of file diff --git a/alternatives/x-cursor-theme b/alternatives/x-cursor-theme new file mode 120000 index 00000000..131c2558 --- /dev/null +++ b/alternatives/x-cursor-theme @@ -0,0 +1 @@ +/usr/share/icons/Adwaita/cursor.theme \ No newline at end of file diff --git a/apt/apt.conf.d/20packagekit b/apt/apt.conf.d/20packagekit new file mode 100644 index 00000000..705cc2fe --- /dev/null +++ b/apt/apt.conf.d/20packagekit @@ -0,0 +1,13 @@ +// THIS FILE IS USED TO INFORM PACKAGEKIT +// THAT THE UPDATE-INFO MIGHT HAVE CHANGED + +// Whenever dpkg is called we might have different updates +// i.e. if an user removes a package that had an update +DPkg::Post-Invoke { +"/usr/bin/test -e /usr/share/dbus-1/system-services/org.freedesktop.PackageKit.service && /usr/bin/test -S /var/run/dbus/system_bus_socket && /usr/bin/gdbus call --system --dest org.freedesktop.PackageKit --object-path /org/freedesktop/PackageKit --timeout 4 --method org.freedesktop.PackageKit.StateHasChanged cache-update > /dev/null; /bin/echo > /dev/null"; +}; + +// When Apt's cache is updated (i.e. apt-cache update) +APT::Update::Post-Invoke-Success { +"/usr/bin/test -e /usr/share/dbus-1/system-services/org.freedesktop.PackageKit.service && /usr/bin/test -S /var/run/dbus/system_bus_socket && /usr/bin/gdbus call --system --dest org.freedesktop.PackageKit --object-path /org/freedesktop/PackageKit --timeout 4 --method org.freedesktop.PackageKit.StateHasChanged cache-update > /dev/null; /bin/echo > /dev/null"; +}; diff --git a/apt/apt.conf.d/99nymea b/apt/apt.conf.d/99nymea new file mode 100644 index 00000000..23dcf22b --- /dev/null +++ b/apt/apt.conf.d/99nymea @@ -0,0 +1,3 @@ +DPkg::Pre-Install-Pkgs {"/usr/libexec/nymea-upgrade-helper"; }; +DPkg::Tools::Options::/usr/libexec/nymea-upgrade-helper::Version "1"; +DPkg::Post-Invoke {"if [ -e /tmp/nymea-restart-pending ]; then systemctl restart nymead; rm /tmp/nymea-restart-pending; fi"; }; diff --git a/chatscripts/gprs b/chatscripts/gprs new file mode 100644 index 00000000..56205933 --- /dev/null +++ b/chatscripts/gprs @@ -0,0 +1,38 @@ +# You can use this script unmodified to connect to cellular networks. +# The APN is specified in the peers file as the argument of the -T command +# line option of chat(8). + +# For details about the AT commands involved please consult the relevant +# standard: 3GPP TS 27.007 - AT command set for User Equipment (UE). +# (http://www.3gpp.org/ftp/Specs/html-info/27007.htm) + +ABORT BUSY +ABORT VOICE +ABORT "NO CARRIER" +ABORT "NO DIALTONE" +ABORT "NO DIAL TONE" +ABORT "NO ANSWER" +ABORT "DELAYED" +ABORT "ERROR" + +# cease if the modem is not attached to the network yet +ABORT "+CGATT: 0" + +"" AT +TIMEOUT 12 +OK ATH +OK ATE1 + +# +CPIN provides the SIM card PIN +#OK "AT+CPIN=1234" + +# +CFUN may allow to configure the handset to limit operations to +# GPRS/EDGE/UMTS/etc to save power, but the arguments are not standard +# except for 1 which means "full functionality". +#OK AT+CFUN=1 + +OK AT+CGDCONT=1,"IP","\T","",0,0 +OK ATD*99# +TIMEOUT 22 +CONNECT "" + diff --git a/chatscripts/pap b/chatscripts/pap new file mode 100644 index 00000000..093c3260 --- /dev/null +++ b/chatscripts/pap @@ -0,0 +1,22 @@ +# You can use this script unmodified to connect to sites which allow +# authentication via PAP, CHAP and similar protocols. +# This script can be shared among different pppd peer configurations. +# To use it, add something like this to your /etc/ppp/peers/ file: +# +# connect "/usr/sbin/chat -v -f /etc/chatscripts/pap -T PHONE-NUMBER" +# user YOUR-USERNAME-IN-PAP-SECRETS +# noauth + +# Uncomment the following line to see the connect speed. +# It will be logged to stderr or to the file specified with the -r chat option. +#REPORT CONNECT + +ABORT BUSY +ABORT VOICE +ABORT "NO CARRIER" +ABORT "NO DIALTONE" +ABORT "NO DIAL TONE" +"" ATZ +OK ATDT\T +CONNECT "" + diff --git a/chatscripts/provider b/chatscripts/provider new file mode 100644 index 00000000..3b34837b --- /dev/null +++ b/chatscripts/provider @@ -0,0 +1,19 @@ +# This is the chat script used to dial out to your default service provider. +# Please customize the entries enclosed in parenthesis to match your setup. +# Only the "provider" file will be handled by poff and pon (unless with +# extra command line arguments). +# +# Remember to edit /etc/ppp/peers/provider accordingly. +# +# ATZW2 as a default init string +# - On all hayes compatible modems, W2 will correctly report the connect +# speed. +# +ABORT BUSY +ABORT "NO CARRIER" +ABORT VOICE +ABORT "NO DIALTONE" +"" ATZW2 +OK ATDT +ogin +word \q diff --git a/dbus-1/system.d/dnsmasq.conf b/dbus-1/system.d/dnsmasq.conf new file mode 100644 index 00000000..03c4eaf8 --- /dev/null +++ b/dbus-1/system.d/dnsmasq.conf @@ -0,0 +1,18 @@ + + + + + + + + + + + + + + + + diff --git a/dbus-1/system.d/io.guh.nymead.conf b/dbus-1/system.d/io.guh.nymead.conf new file mode 100644 index 00000000..4106861d --- /dev/null +++ b/dbus-1/system.d/io.guh.nymead.conf @@ -0,0 +1,14 @@ + + + + + + + + + + + + diff --git a/dbus-1/system.d/org.freedesktop.ModemManager1.conf b/dbus-1/system.d/org.freedesktop.ModemManager1.conf new file mode 100644 index 00000000..8087da6f --- /dev/null +++ b/dbus-1/system.d/org.freedesktop.ModemManager1.conf @@ -0,0 +1,344 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/dbus-1/system.d/org.freedesktop.PackageKit.conf b/dbus-1/system.d/org.freedesktop.PackageKit.conf new file mode 100644 index 00000000..110df894 --- /dev/null +++ b/dbus-1/system.d/org.freedesktop.PackageKit.conf @@ -0,0 +1,33 @@ + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/environment.d/90qt-a11y.conf b/environment.d/90qt-a11y.conf new file mode 100644 index 00000000..46a63b29 --- /dev/null +++ b/environment.d/90qt-a11y.conf @@ -0,0 +1 @@ +QT_ACCESSIBILITY=1 diff --git a/gtk-3.0/im-multipress.conf b/gtk-3.0/im-multipress.conf new file mode 100644 index 00000000..d6c8129d --- /dev/null +++ b/gtk-3.0/im-multipress.conf @@ -0,0 +1,22 @@ +# Example configuration file for the GTK+ Multipress Input Method +# Authored by Openismus GmbH, 2009. +# +# This file follows the GKeyFile format. On the left of the equal sign goes +# the key that you press repeatedly to iterate through the text items listed +# on the right-hand side. The list items are separated by semicolons ";" and +# consist of one or more characters each. The backslash "\" is used to escape +# characters; for instance "\;" for a literal semicolon. +# +# The example configuration below imitates the behavior of a standard mobile +# phone by a major manufacturer, with German language setting. +[keys] +KP_1 = .;,;?;!;';";1;-;(;);@;/;:;_ +KP_2 = a;b;c;2;ä;à;á;ã;â;å;æ;ç +KP_3 = d;e;f;3;è;é;ë;ê;ð +KP_4 = g;h;i;4;ì;í;î;ï +KP_5 = j;k;l;5;£ +KP_6 = m;n;o;6;ö;ò;ó;ô;õ;ø;ñ +KP_7 = p;q;r;s;7;ß;$ +KP_8 = t;u;v;8;ü;ù;ú;û +KP_9 = w;x;y;z;9;ý;þ +KP_0 = \s;0 diff --git a/logrotate.d/nymead b/logrotate.d/nymead new file mode 100644 index 00000000..ccbb7b24 --- /dev/null +++ b/logrotate.d/nymead @@ -0,0 +1,10 @@ +/var/log/nymead.log { + rotate 7 + daily + dateext + compress + delaycompress + missingok + notifempty + create 755 root root +} diff --git a/logrotate.d/ppp b/logrotate.d/ppp new file mode 100644 index 00000000..35054639 --- /dev/null +++ b/logrotate.d/ppp @@ -0,0 +1,9 @@ +/var/log/ppp-connect-errors { + weekly + rotate 4 + missingok + notifempty + compress + nocreate +} + diff --git a/nymea/nymead.conf b/nymea/nymead.conf new file mode 100644 index 00000000..8161c70a --- /dev/null +++ b/nymea/nymead.conf @@ -0,0 +1,53 @@ +[BluetoothServer] +enabled=false + +[Logs] +logDBDriver=QSQLITE +logDBHost=127.0.0.1 +logDBMaxEntries=200000 +logDBName=/var/log/nymead.sqlite +logDBPassword= +logDBUser= + +[MqttServer] +default\address=0.0.0.0 +default\authenticationEnabled=true +default\port=1883 +default\sslEnabled=false + +[SSL] +certificate= +certificate-key= + +[TcpServer] +default\address=0.0.0.0 +default\authenticationEnabled=true +default\port=2222 +default\sslEnabled=true + +[WebServer] +insecure\address=0.0.0.0 +insecure\authenticationEnabled=false +insecure\port=80 +insecure\publicFolder=/usr/share/nymea-webinterface/public/ +insecure\restServerEnabled=false +insecure\sslEnabled=false +secure\address=0.0.0.0 +secure\authenticationEnabled=false +secure\port=443 +secure\publicFolder=/usr/share/nymea-webinterface/public/ +secure\restServerEnabled=false +secure\sslEnabled=true + +[WebSocketServer] +default\address=0.0.0.0 +default\authenticationEnabled=true +default\port=4444 +default\sslEnabled=true + +[nymead] +debugServerEnabled=false +language=en_US +name=nymea +timeZone=@ByteArray() +uuid={5fd92f79-0d68-40e2-b8fc-4feb29678576} diff --git a/nymea/user-db.sqlite b/nymea/user-db.sqlite new file mode 100644 index 00000000..eb1915fb Binary files /dev/null and b/nymea/user-db.sqlite differ diff --git a/openzwave/2gig/ct100.xml b/openzwave/2gig/ct100.xml new file mode 100644 index 00000000..24973f45 --- /dev/null +++ b/openzwave/2gig/ct100.xml @@ -0,0 +1,250 @@ + + + http://www.openzwave.com/device-database/0098:0106:6401 + images/2gig/ct100.png + https://products.z-wavealliance.org/products/795/ + Australia / New Zealand / U.S. / Canada / Mexico + CT100 Plus + The CT100 Plus is a sleek, modern thermostat design for home automation systems. It’s clean user interface compliments app-enabled systems. It features adjustable real-time alerts to enable cloud triggers, a robust data stream of HVAC information for cloud monitoring, and configurable comfort response settings to customize home control scenes. The CT100 Plus is compatible with all popular HVAC systems and is battery-operated without the need for a C-wire. + CT100-US + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/782/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/795/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1798/xml + + https://products.z-wavealliance.org/products/1798/ + Switch the thermostat to Off Mode. Press and hold the lower left corner of touch screen for five (5) seconds. The thermostat then resets itself, displays its current firmware version, and restarts in Off Mode. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + CT100 + Same process as inclusion. Similarly, when you are trying to exclude from a network, the LINK icon disappears when the node has successfully excluded the network. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1798/CT100_Plus_UserGuide_20160504.pdf + U.S. / Canada / Mexico + When included into a Z-Wave network on battery power, this device is a FLiRS device. The Thermostat will wake up for communication when it receives a valid Z-Wave beam. + From the CT100’s Menu screen, touch MATE under the radio icon. The Network Include screen displays a large r1. Touch MATE again. This initiates the network inclusion process. The MATE icon and the status indicator LEDs will blink. When the CT100 has successfully included into a Z-Wave network, the +MATE icon is replaced by the LINK icon under the radio tower. + + + + + + 0 + + + + + + The Temperature Reporting Threshold Configuration Set Command sets the reporting threshold for changes in the ambient temperature as detected by the thermostat. + + + + + + + + + + Bits 0 - 7 -> HVAC Setup: Normal (0x01) or Heat Pump (0x02) + Bits 8 - 11 -> Number of Auxiliary Stages (Heat Pump) / Number of Heat Stages (Normal) + Bits 12 - 15 -> Aux Setup: Gas (0x01) or Electric (0x02) + Bits 16 - 23 -> Number of Heat Pump Stages + Bits 24 - 31 -> Number of Cool Stages + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + The Utility Lock Configuration Set command enables or disables the utility lock. + If the utility lock is enabled, the setpoint cannot be modified directly via the thermostat screen. + + + + + + + 1 -> C-Wire + 2 -> Battery + + + + + + + The Humidity Reporting Threshold Configuration Set Command sets the reporting threshold for changes in the relative humidity as detected by the thermostat. + + + + + + + + + The Auxiliary/Emergency configuration command enables or disables auxiliary / emergency heating in the thermostat. + Auxiliary / emergency heating is only available if the thermostat is configured in heat pump mode and with at least one stage of auxiliary heating. + This command enables auxiliary / emergency heating when the thermostat is in Auto mode. + The Thermostat Set Mode command with mode Auxiliary/Emergency Heat will enable emergency heating but only if the thermostat is in Heat mode. + This command should only be used on thermostats that support Auxiliary/Emergency Heat thermostat mode. + + + + + + + Thermostat Swing Temperature configuration command sets the maximum allowed difference between ambient temperature and the set temperature. + + + + + + + + + + + + + (Set Only) The Thermostat Differential Temperature configuration command sets the differential temperature for multi-stage HVAC systems. + The differential temperature delta defines when the thermostat will turn on additional stages. + There are two differential temperatures, one for multistage cool systems and one for multistage heat systems. + If the thermostat is not configured for multistage HVAC systems then these parameters have no effect. + + + + + + + + + + + + + + + The Thermostat Recovery Mode configuration command sets the HVAC recovery mode type. + The recovery mode determines when additional HVAC stages are turned off as the ambient temperature returns to the target temperature. + If the recovery mode is set to economy, the thermostat will turn off additional HVAC stages when the ambient temperature reaches the target temperature plus/minus the differential temperature. + If the recovery mode is set to fast, the thermostat will leave all stages on (assuming they were already on) until the ambient temperature reaches the target temperature. + + + + + + + The Temperature Reporting Filter configuration command sets upper and lower bounds of the ambient temperature reporting. + The thermostat won't report ambient temperature changes if the ambient temperature falls between these bounds. + For example, if the upper bound is 80F and the lower bound is 60F, the thermostat will not send SENSOR_MULTI_LEVEL_REPORTS for ambient temperature values between 60F and 80F. + The thermostat will only send ambient temperature changes if the thermostat has been added to an association group (see Command Class Association) and the temperature reporting threshold is non-zero (see Temperature Reporting Threshold). + Input in hexadecimal only like so: 0x09 0x05 0x09 0x0A. + It must always have four 1 byte sized numbers. + The first two bytes control the lower temperature bound for the Temperature Reporting Filter the last two control the upper temperature bound. + The first byte in the byte pair always refers to temperature scale (Celsius 0x01 or Fahrenheit 0x09). + While the second byte in each byte pair is the bound temperature. + The max/min temp you can use is 127 degrees. + To convert decimal to hex goto: https://www.binaryhexconverter.com/decimal-to-hex-converter or you can use the built in Windows calculator program in Programmer mode. + If you mess up your thermostat copy and paste 0x09 0x00 0x09 0x00 (for a F Thermostat) or 0x01 0x00 0x01 0x00 (for a C Thermostat). + This will remove any bounds. + + + + + Simple UI Mode Enable/Disable + + + + + + + Multicasting Enable/Disable + + + + + + + 1 -> Adjust by target delta + 2 -> Least consuming point in the running program + 3 -> Save energy absolute setpoint + 255 -> Save Energy not supported + + + + + + + + + + + + + diff --git a/openzwave/2gig/ct101.xml b/openzwave/2gig/ct101.xml new file mode 100644 index 00000000..695dd4f6 --- /dev/null +++ b/openzwave/2gig/ct101.xml @@ -0,0 +1,8 @@ + + + + + 0 + + + diff --git a/openzwave/2gig/ct30.xml b/openzwave/2gig/ct30.xml new file mode 100644 index 00000000..605957f7 --- /dev/null +++ b/openzwave/2gig/ct30.xml @@ -0,0 +1,97 @@ + + + + + 0 + + + + + + The Temperature Reporting Threshold Configuration Set Command sets the reporting threshold for changes in the ambient temperature as detected by the thermostat. + + + + + + + + + + Read-only parameter + 0 - 7 -> HVAC Setup: Normal (0x01) or Heat Pump (0x02) + 8 - 11 -> Number of Auxiliary Stages (Heat Pump) / Number of Heat Stages (Normal) + 12 - 15 -> Aux Setup: Gas (0x01) or Electric (0x02) + 16 - 23 -> Number of Heat Pump Stages + 24 - 31 -> Number of Cool Stages + + + + + The Utility Lock Configuration Set command enables or disables the utility lock. If the utility lock is enabled, the setpoint cannot be modified directly via the thermostat screen. + + + + + + + Read-only parameter + 1 -> C-Wire + 2 -> Battery + + + + + The Temperature Reporting Threshold Configuration Set Command sets the reporting threshold for changes in the ambient temperature as detected by the thermostat. + + + + + + + + + The Auxiliary/Emergency configuration command enables or disables auxiliary / emergency heating in the thermostat. Auxiliary / emergency heating is only available if the thermostat is configured in heat pump mode and with at least one stage of auxiliary heating. This command enables auxiliary / emergency heating when the thermostat is in Auto mode. The Thermostat Set Mode command with mode Auxiliary/Emergency Heat will enable emergency heating but only if the thermostat is in + Heat mode. This command should only be used on thermsotats that support Auxiliary/Emergency Heat thermostat mode. + + + + + + + The Auxiliary/Emergency configuration command enables or disables auxiliary/emergency heating in the thermostat. Auxiliary/emergency heating is only available if the thermostat is configured in heat pump mode and with at least one stage of auxiliary heating. This command enables auxiliary / emergency heating when the thermostat is in Auto mode. The Thermostat Set Mode command with mode Auxiliary/Emergency Heat will enable emergency heating but only if the thermostat is in Heat + mode. This command should only be used on thermsotats that support Auxiliary/Emergency Heat thermostat mode. + + + + + + + + The Thermostat Differential Temperature configuration command sets the differential temperature for multi-stage HVAC systems. The differential temperature delta defines when the thermostat will turn on additional stages. There are two differential temperatures, one for multistage cool systems and one for multistage heat systems. If the thermostat is not configured for multistage HVAC systems then these parameters have no effect. + + + + + + + + The Thermostat Recovery Mode configuration command sets the HVAC recovery mode type. The recovery mode determines when additional HVAC stages are turned off as the ambient temperature returns to the target temperature. If the recovery mode is set to economy, the thermostat will turn off additional HVAC stages when the ambient temperature reaches the target temperature plus/minus the differential temperature. If the recovery mode is set to fast, the thermostat will leave all + stages on (assuming they were already on) until the ambient temperature reaches the target temperature. + + + + + + + The Temperature Reporting Filter configuration command sets upper and lower bounds of the ambient temperature reporting. The thermostat will not report ambient temperature changes if the ambient temperature falls between these bounds. For example, if the upper bound is 80F and the lower bound is 60F, the thermostat will not send SENSOR_MULTI_LEVEL_REPORTS for ambient temperature values between 60F and 80F. The thermostat will only send ambient temperature changes if the + thermostat has been added to an association group (see Command Class Association) and the temperature reporting threshold is non-zero (see Temperature Reporting Threshold). + + + + + + + + + diff --git a/openzwave/2gig/ct32.xml b/openzwave/2gig/ct32.xml new file mode 100644 index 00000000..9577470d --- /dev/null +++ b/openzwave/2gig/ct32.xml @@ -0,0 +1,240 @@ + + + http://www.openzwave.com/device-database/0098:0100:2002 + images/2gig/ct32.png + https://products.z-wavealliance.org/products/1330/ + When included into a Z-Wave network on battery power, this device is a FLiRS device. The Thermostat will wake up for communication when it receives a valid Z-Wave beam. + CT32 + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1330/RTZW-02_module_IB_11jun15_web.pdf + Go to Menu screen, and press INCLUDE icon. + CT32 + Go to Menu screen, and press EXCLUDE icon. + The Z-Wave enabled CT32 thermostat is a compact, easy-to-use thermostat that is packed with functionality. The CT32 has a responsive touchscreen interface, easy-to-read backlight display, and 7-day programmability. It features a system lock to avoid unintentional changes for maximum efficiency, a filter change indicator to keep your HVAC system running efficiently, wide temperature operation range, and room temperature calibration for precise control. + In Main menu, put thermostat in OFF mode. Press and hold center digits. Use the reset procedure only when the primary controller is missing or inoperable. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1046/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1330/xml + Force root instance to map to first endpoint via compat flag MapRootToEndpoint + Force Setpoint Interpretion A and update some config parameters. + + + + + + + 0 + false + + + + + true + + + + + + The Temperature Reporting Threshold Configuration Set Command sets the reporting threshold for changes in the ambient temperature as detected by the thermostat. + + + + + + + + + + Bits 0 - 7 -> HVAC Setup: Normal (0x01) or Heat Pump (0x02) + Bits 8 - 11 -> Number of Auxiliary Stages (Heat Pump) / Number of Heat Stages (Normal) + Bits 12 - 15 -> Aux Setup: Gas (0x01) or Electric (0x02) + Bits 16 - 23 -> Number of Heat Pump Stages + Bits 24 - 31 -> Number of Cool Stages + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + The Utility Lock Configuration Set command enables or disables the utility lock. + If the utility lock is enabled, the setpoint cannot be modified directly via the thermostat screen. + + + + + + + 1 -> C-Wire + 2 -> Battery + + + + + + + The Humidity Reporting Threshold Configuration Set Command sets the reporting threshold for changes in the ambient humidity as detected by the thermostat. + + + + + + + + + The Auxiliary/Emergency configuration command enables or disables auxiliary / emergency heating in the thermostat. + Auxiliary / emergency heating is only available if the thermostat is configured in heat pump mode and with at least one stage of auxiliary heating. + This command enables auxiliary / emergency heating when the thermostat is in Auto mode. + The Thermostat Set Mode command with mode Auxiliary/Emergency Heat will enable emergency heating but only if the thermostat is in Heat mode. + This command should only be used on thermsotats that support Auxiliary/Emergency Heat thermostat mode. + + + + + + + The Temperate Swing (HVAC cycling rate) is the desired variance in temperature between the thermostat setting and the room temperature required before the heating or cooling system will turn on. + + + + + + + + + + + + + (Set Only) The Thermostat Differential Temperature configuration command sets the differential temperature for multi-stage HVAC systems. + The differential temperature delta defines when the thermostat will turn on additional stages. + There are two differential temperatures, one for multistage cool systems and one for multistage heat systems. + If the thermostat is not configured for multistage HVAC systems then these parameters have no effect. + + + + + + + + + + + + + + + The Thermostat Recovery Mode configuration command sets the HVAC recovery mode type. + The recovery mode determines when additional HVAC stages are turned off as the ambient temperature returns to the target temperature. + If the recovery mode is set to economy, the thermostat will turn off additional HVAC stages when the ambient temperature reaches the target temperature plus/minus the differential temperature. + If the recovery mode is set to fast, the thermostat will leave all stages on (assuming they were already on) until the ambient temperature reaches the target temperature. + + + + + + + The Temperature Reporting Filter configuration command sets upper and lower bounds of the ambient temperature reporting. The thermostat will not report ambient temperature changes if the ambient temperature falls between these bounds. For example, if the upper bound is 80F and the lower bound is 60F, the thermostat will not send SENSOR_MULTI_LEVEL_REPORTS for ambient temperature values between 60F and 80F. The thermostat will only send ambient temperature changes if the + thermostat has been added to an association group (see Command Class Association) and the temperature reporting threshold is non-zero (see Temperature Reporting Threshold). + + + + + The Temperature Reporting Filter configuration command sets upper and lower bounds of the ambient temperature reporting. + The thermostat won't report ambient temperature changes if the ambient temperature falls between these bounds. + For example, if the upper bound is 80F and the lower bound is 60F, the thermostat will not send SENSOR_MULTI_LEVEL_REPORTS for ambient temperature values between 60F and 80F. + The thermostat will only send ambient temperature changes if the thermostat has been added to an association group (see Command Class Association) and the temperature reporting threshold is non-zero (see Temperature Reporting Threshold). + Input in hexadecimal only like so: 0x09 0x05 0x09 0x0A. + It must always have four 1 byte sized numbers. + The first two bytes control the lower temperature bound for the Temperature Reporting Filter the last two control the upper temperature bound. + The first byte in the byte pair always refers to temperature scale (Celsius 0x01 or Fahrenheit 0x09). + While the second byte in each byte pair is the bound temperature. + The max/min temp you can use is 127 degrees. + To convert decimal to hex goto: https://www.binaryhexconverter.com/decimal-to-hex-converter or you can use the built in Windows calculator program in Programmer mode. + If you mess up your thermostat copy and paste 0x09 0x00 0x09 0x00 (for a F Thermostat) or 0x01 0x00 0x01 0x00 (for a C Thermostat). + This will remove any bounds. + + + + + If the value is set to Disable then Normal Mode is enabled. If the value is set to Enable then Simple Mode is enabled. + + + + + + + If set to 0, multicast is disabled, if set to 1, will enable the multicast. + + + + + + + + + diff --git a/openzwave/2gig/ct50e.xml b/openzwave/2gig/ct50e.xml new file mode 100644 index 00000000..27423360 --- /dev/null +++ b/openzwave/2gig/ct50e.xml @@ -0,0 +1,9 @@ + + + + + + 0 + + + diff --git a/openzwave/2gig/ct80.xml b/openzwave/2gig/ct80.xml new file mode 100644 index 00000000..74e4de53 --- /dev/null +++ b/openzwave/2gig/ct80.xml @@ -0,0 +1,9 @@ + + + + + + 0 + + + diff --git a/openzwave/BeNext/1poleswitch.xml b/openzwave/BeNext/1poleswitch.xml new file mode 100644 index 00000000..342721ea --- /dev/null +++ b/openzwave/BeNext/1poleswitch.xml @@ -0,0 +1,35 @@ + + + + + + + + Set all configuration values to default values (factory settings). + + + + The mode in which a different Z-Wave message is sent. + + + + The time that a user has to activate the double button pressed scene, if time is passed then the single pressed button scene is notified. (value * 10 ms) + + + + A signed integer to determine the offset of the temperature. + + + + + + + + + + + + + + + diff --git a/openzwave/BeNext/2poleswitch.xml b/openzwave/BeNext/2poleswitch.xml new file mode 100644 index 00000000..dc8b013c --- /dev/null +++ b/openzwave/BeNext/2poleswitch.xml @@ -0,0 +1,35 @@ + + + + + + + + Set all configuration values to default values (factory settings). + + + + The mode in which a different Z-Wave message is sent. + + + + The time that a user has to activate the double button pressed scene, if time is passed then the single pressed button scene is notified. (value * 10 ms) + + + + A signed integer to determine the offset of the temperature. + + + + + + + + + + + + + + + diff --git a/openzwave/BeNext/AlarmSound.xml b/openzwave/BeNext/AlarmSound.xml new file mode 100644 index 00000000..c18786f0 --- /dev/null +++ b/openzwave/BeNext/AlarmSound.xml @@ -0,0 +1,486 @@ + + + http://www.openzwave.net/device-database/008a:0101:0005 + images/BeNext/AlarmSound.png + https://products.z-wavealliance.org/products/51 + The Alarm Sound is a plug and play product developed by BeNext. Depending on present situations and scenes it sets off an alarm sound warning you and your family or scaring off unwanted activities. Use the Alarm Sound for security purposes and notifications indoors. +Use the Alarm Sound in combination with the Door Sensor or MoLite Sensor to alert you when someone undesirably enters your home or work-space. The Alarm Sound possesses six different sound- and lighting-configurations to scare off any possible intruder. You can also customize personal preferred ‘scenes’ and ‘rules’ in our free of charge online manager in order to give the Alarm Sound dual functionality. You can even choose to create a new kind of alarm clock, which in combination with the Door Sensor or MoLite Sensor gives a wake up alarm if you haven’t left your bedroom after 09:00 am. + + www.benext.eu/en/products/alarm-sound/ + Info@Benext.eu + Alarm Sound + CEPT (Europe) + BeNeXt / Alarm Sound + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/51/XML + + + + + + false + + + + + + + Set all configuration values to default values (factory settings) + + + Enables an internal routine that periodically checks the Z-Wave device in assocication group 2 + + + Configure the time that the AlarmSound sends a new frame when previous frame was send successful + + + Configure the time that the AlarmSound sends a few frame when previous frame was send not successful + + + A (signed) offset to calibrate the onboard temperature sensor + + + A (signed) offset to calibrate the onboard temperature sensor + + + The index of the sound mode when a switch binary/basic set frame is received + + + + + + + + + + The index of the sound mode when the AlarmSound will start when it is unplugged + + + + + + + + + + + The index of the sound mode when the AlarmSound will play when it is unable to reach the device in association group 2 + + + + + + + + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 161 + + + Default value : 1 + + + Default value : 200 + + + Default value : 00 + + + Default value : 26 + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 20 + + + Default value : 255 + + + Default value : 00 + + + Default value : 16 + + + + Default value : 255 + + + Default value : 66 + Bit 7: reserved + Bit 6: step1: sound on + Bit 5: step1: leds on + Bit 4: step1: pause on + Bit 3: reserved + Bit 2: step2: sound on + Bit 1: step2: leds on + Bit 0: step2: pause on + + + + Default value : 0 + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 161 + + + Default value : 1 + + + Default value : 200 + + + Default value : 00 + + + Default value : 26 + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 20 + + + Default value : 255 + + + Default value : 00 + + + Default value : 16 + + + + Default value : 255 + + + Default value : 66 + Bit 7: reserved + Bit 6: step1: sound on + Bit 5: step1: leds on + Bit 4: step1: pause on + Bit 3: reserved + Bit 2: step2: sound on + Bit 1: step2: leds on + Bit 0: step2: pause on + + + + Default value : 0 + + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 161 + + + Default value : 1 + + + Default value : 200 + + + Default value : 00 + + + Default value : 26 + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 20 + + + Default value : 255 + + + Default value : 00 + + + Default value : 16 + + + + Default value : 255 + + + Default value : 66 + Bit 7: reserved + Bit 6: step1: sound on + Bit 5: step1: leds on + Bit 4: step1: pause on + Bit 3: reserved + Bit 2: step2: sound on + Bit 1: step2: leds on + Bit 0: step2: pause on + + + + Default value : 0 + + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 161 + + + Default value : 1 + + + Default value : 200 + + + Default value : 00 + + + Default value : 26 + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 20 + + + Default value : 255 + + + Default value : 00 + + + Default value : 16 + + + + Default value : 255 + + + Default value : 66 + Bit 7: reserved + Bit 6: step1: sound on + Bit 5: step1: leds on + Bit 4: step1: pause on + Bit 3: reserved + Bit 2: step2: sound on + Bit 1: step2: leds on + Bit 0: step2: pause on + + + + Default value : 0 + + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 161 + + + Default value : 1 + + + Default value : 200 + + + Default value : 00 + + + Default value : 26 + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 20 + + + Default value : 255 + + + Default value : 00 + + + Default value : 16 + + + + Default value : 255 + + + Default value : 66 + Bit 7: reserved + Bit 6: step1: sound on + Bit 5: step1: leds on + Bit 4: step1: pause on + Bit 3: reserved + Bit 2: step2: sound on + Bit 1: step2: leds on + Bit 0: step2: pause on + + + + Default value : 0 + + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 161 + + + Default value : 1 + + + Default value : 200 + + + Default value : 00 + + + Default value : 26 + + + + Default value : 99 + + + Default value : 03 + + + Default value : 232 + + + Default value : 20 + + + Default value : 255 + + + Default value : 00 + + + Default value : 16 + + + + Default value : 255 + + + Default value : 66 + Bit 7: reserved + Bit 6: step1: sound on + Bit 5: step1: leds on + Bit 4: step1: pause on + Bit 3: reserved + Bit 2: step2: sound on + Bit 1: step2: leds on + Bit 0: step2: pause on + + + + Default value : 0 + + + + + + + + + + + + diff --git a/openzwave/BeNext/BuiltinDimmer.xml b/openzwave/BeNext/BuiltinDimmer.xml new file mode 100644 index 00000000..78ab2ee9 --- /dev/null +++ b/openzwave/BeNext/BuiltinDimmer.xml @@ -0,0 +1,77 @@ + + + + + + + + Set all configuration values to default values (factory settings). + + + + The way how the button reacts when press/released + + + + + + + The way the Built-in Dimmer reacts when light is turned on/off with button + + + + + + This parameter is used to enable the dimming option of the product. When disabled the dimming and fading routine are disabled. + + + + + + The maximum powerload in watts when light is turned on, when measured higher then this value the Inline Dimmer is automatically turned off. + + + + The speed of dimming when activated (manual and RF). Dim speed is 1% per value (* 10 ms) + + + + The speed of fading up when activated (manual and RF). Fade speed is 1% per value (* 10 ms) + + + + The time window to repress button to start dimming. Toggle time is value (* 10ms) + + + + A percentage that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 10% Maximum value = 100% + + + + A watt value that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 5 watt Maximum value = 255 watt + + + + A time value that has to be passed compared to a previous sent value before a unsolicited meter report is sent. Minimum value = 10 seconds Maximum value = 255 seconds + + + + What to do with lamp status when power applied. If 0x00: Always switch light off when power applied. If > 0x00: Switch lamp on/off depending on last known lampstatus before power was disconnected. + + + + The speed of fading up when activated (manual and RF). Fade speed is 1% per value (* 10 ms) + + + + + + + + + + + + + + diff --git a/openzwave/BeNext/DoorSensor.xml b/openzwave/BeNext/DoorSensor.xml new file mode 100644 index 00000000..557f5c1d --- /dev/null +++ b/openzwave/BeNext/DoorSensor.xml @@ -0,0 +1,84 @@ + + + http://www.openzwave.com/device-database/008A:0100:0004 + images/BeNext/DoorSensor.png + https://products.z-wavealliance.org/products/75/ + A 2-in-1 product The primary function of the Door Sensor is detecting the status of a door or window. Due to it’s build in thermometer you can also measure temperature on that location. Use the Door Sensor for; - Security - Comfort -Lighting - Automation and Saving money. +- Temperature sensor inside +- External contact for additional sensor or doorbell-push button + +Use The Door Sensor for securing and/or enlarging luxury and automation in your home or office. Receive notifications when unwanted activities are being triggered and keep your room temperature on level due to the build-in thermometer. Make up your own rules in the free of charge online manager so that your preferences are automated when simply opening your front door. +The primary function of the Door Sensor is detecting the status of a door or window. In combination with our Alarm Sound you can configure rules that enable an alarm when doors or windows are opened unwanted. Broaden functionalities by making your own rules. Make it happen that when you leave your bedroom, any preferred devices and custom scenes switch on and off, depending on the time of day. + +- Long battery operation time - Temperature sensor - Extra external contact - Good priced + +The dimensions are 3,3 x 5,8 x 1,8cm (LxBxH). The color of the product is traffic White, RAL 9016. Electrical specs can be found on http://www.benext.eu/en/products/door-sensor/ +• Measure the open and/or closed status of doors and windows in your office or home +• Measure temperature +• Set up a basic security system by simply adding more sensors +• Receive notifications on your phone and email when there is registered activity +• Make up a variety of rules to add functionality to your home +• Use for security and adding luxury to your office or home +• Save on your energy bills by reducing unwanted usage of heating +• Product dimensions: Door Sensor = 58 x 33 x 17 millimeter. Magnet = 58 x 11 x 17 millimeter (L x W x H) +• Normal operating voltage: 2x AAA 1,5V batteries. From 2,3 to 4,0Vdc. Do not use rechargeable batteries +• Battery lifetime: approximately 5 years by normal usage. Approximately 3~4 years by long networks and heavily usage +• Absolute maximum temperature: -15°C to +85°C + + www.benext.eu/en/products/door-sensor + Info@Benext.eu + Door Sensor + CEPT (Europe) + BeNeXt / Door Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/75/xml + + + + + + Set all configuration values to default values (factory settings). + + + Configure what the external contact sends when triggered. (Default: 0) + + + + + Is not used but can still be set and requested. + + + Is not used but can still be set and requested. + + + To configure the operating mode. (Default: 1) + + + + + A signed integer to determine the offset of the temperature. (Default: 0) + + + Debounce time when the external contact is opened. (Default: 0) + + + Debounce time when the external contact is opened. (Default 0) + + + A delay from the wake up time to give the external contact a chance to change his status. (Default 0, value * 100 ms, 0 - 25,5 seconds) + + + + + + false + + + + + + + + + + diff --git a/openzwave/BeNext/EnergySwitch.xml b/openzwave/BeNext/EnergySwitch.xml new file mode 100644 index 00000000..32d5535f --- /dev/null +++ b/openzwave/BeNext/EnergySwitch.xml @@ -0,0 +1,30 @@ + + + + + + Set all configuration values to default values (factory settings). + + + The state in what the switch is when power is supplied. + + + + + When the relay is switched it can't be switched again until the configured time has passed. + + + Show the led state compared to the relay state. + + + + + + + + + + + + + diff --git a/openzwave/BeNext/HeatingControl.xml b/openzwave/BeNext/HeatingControl.xml new file mode 100644 index 00000000..9e42ad5f --- /dev/null +++ b/openzwave/BeNext/HeatingControl.xml @@ -0,0 +1,76 @@ + + + + + + + + + + + + + + + + + + + 0 + true + + + + + + 0xFF: Set all configuration values to default values (factory settings). + CONFIGURATION_REPORT + 0x55: Configuration settings of the device are altered. + 0xAA: Configuration of the device is untouched. + Note that this value will not change to 0x55 upon modifying the wake up interval and that re-setting the value to 0xAA will always reset the wake up interval. + + + + The interval that data is requested (and therefore updated) from the thermostat and boiler. Value in seconds. + + + The value that the room temperature must differ (compared to his previous send value) before an unsolicited room temperature report is send to the associated node. Value in 0.1C. + + + The value that the temperature setpoint must differ (compared to his previous send value) before an unsolicited temperature setpoint report is send to the associated node. Value in 0.1C . + + + TConfigure if the unsolicited reports are send with the CRC-16 encapsulation. Not that the receiving node should support this encapsulation to parse the Z-Wave frame! + + + + + Type of 'special' thermostat: NOTE: when remeha Celcia 20 support is set then any other thermostat can not be set (!) NOTE2: when Remeha Celcia 20 gives 'Fout 203' send cfg value again + + + + + + Status auto report boiler/thermostat report + + + + + Enable/Disable thermostat schedule inside the heating controller. + + + + + + + + false + + + + + + + + + diff --git a/openzwave/BeNext/Molite.xml b/openzwave/BeNext/Molite.xml new file mode 100644 index 00000000..0ae0961c --- /dev/null +++ b/openzwave/BeNext/Molite.xml @@ -0,0 +1,91 @@ + + + http://www.openzwave.com/device-database/008A:0100:0003 + images/BeNext/Molite.png + https://products.z-wavealliance.org/products/76/ + http://www.benext.eu/en/products/molite-sensor/ + With the Molite Sensor it is possible to measure movement, light and temperature. Utilize the MoLite Sensor for a variety of BeNext system features such as + +- Security +- Personal Comfort +- Lighting +- General Automation + +Visit our website for a full description +http://www.benext.eu/en/products/molite-sensor/ + + info@benext.eu + MoLiTe Sensor + CEPT (Europe) + MoLiTe + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/76/xml + + + + + + Set all configuration values to default values (factory settings). + + + The time used in mode 2 to turn the sensor off. This Time will start running as soon as detection is seen. + + + The switch off time will start running as soon as mode timeout is done. Motion sensor is turned on and when movement is detected again the mode timeout (cfg param 1) will start running all over again. When switch off time is done a basic off message is sent to the associated node. + + + Sensitivity value between 0 and 127 (values above 127 will be reported as the set value but will be handled in SW as 127). + + + The mode that is entered after detection. If mode is 0 or higher then 3, that value will be reported after a get but will be handled in SW as mode 2. + + + + + + An offset for the temperature + + + If a LDR resistance measured lower than this value the returned light percentage is 100%. See chapter light table for more information. + + + If a LDR resistance measured lower than this value the returned light percentage is 90%. See chapter light table for more information. + + + If a LDR resistance measured lower than this value the returned light percentage is 80%. See chapter light table for more information. + + + If a LDR resistance measured lower than this value the returned light percentage is 70%. See chapter light table for more information. + + + If a LDR resistance measured lower than this value the returned light percentage is 60%. See chapter light table for more information. + + + If a LDR resistance measured lower than this value the returned light percentage is 50%. See chapter light table for more information. + + + If a LDR resistance measured lower than this value the returned light percentage is 40%. See chapter light table for more information. + + + If a LDR resistance measured lower than this value the returned light percentage is 30%. See chapter light table for more information. + + + If a LDR resistance measured lower than this value the returned light percentage is 20%. See chapter light table for more information. + + + If a LDR resistance measured lower than this value the returned light percentage is 10%. See chapter light table for more information. + + + + + + true + + + + + + + + + diff --git a/openzwave/BeNext/P1dongle.xml b/openzwave/BeNext/P1dongle.xml new file mode 100644 index 00000000..8dd04bc2 --- /dev/null +++ b/openzwave/BeNext/P1dongle.xml @@ -0,0 +1,81 @@ + + + + P1 Dongle + + +If your Internet Gateway is not in the vicinity of the smart meter, you can use a P1-dongle. The P1-dongle sends data wirelessly to the Internet Gateway. This data is shown in your BeNext application and online environment. Here you can get insight of your consumption and things like the overall yield of your solar panels. + +Support: +The P1-dongle can connect to smart meters that support DSMR (Dutch Smart Meter Reader Protocol). We support all smart meters* with a P1-connector. +The following smart meter brands have this connection: Kaifa, Kamstrup, Landis & Gyr, Elster and Iskra. +* DSMR2, 4 and 5 + +For more information about smart meters: https://www.benext.eu/producten/slimme-meter/. +Order a special adapter for DSMR2.x meters. + + http://www.openzwave.com/device-database/008A:0100:002F + https://www.benext.eu/en/products/p1-dongle/ + https://support.benext.eu/ + images/BeNext/P1dongle.png + https://www.benext.eu/static/manual/P1_dongle-nl.pdf + CEPT (Europe) + P1 Dongle + + Added Metadata as of template, removed commandclass ID 50, should be interviewed, changed max_associations of lifeline group as of manual + + + + + + Set all configuration values to default values (factory settings). + + + For some Smart meters you will need an external pullup resistor to receive the data, one of it is the Kaifa meter. 0x00: disabled. 0x01-0xFF: enabled (default 0x00) + + + value x 100 = baud rate + + + Settings for data validation LED. Bit 7-4: Data received timeout (x 10). Bit 3-0: Framecount when data is valid (default 0x33 (0x30|0x03)) + + + + + + + + Conditions current usage will be automatically reported. Param 1-3: Difference in absolute value. Param 4: Difference in percentage between previous and current value. (default 0x0000050A (5Watt and 10%)) + + + Conditions current usage will be automatically reported. Param 1-3: Difference in absolute value. Param 4: Difference in percentage between previous and current value. (default 0x00006400 (0.1kWh and 0%)) + + + Conditions current delivered will be automatically reported. Param 1-3: Difference in absolute value. Param 4: Difference in percentage between previous and current value. (default 0x0000050A (5Watt and 10%)) + + + Conditions current delivered will be automatically reported. Param 1-3: Difference in absolute value. Param 4: Difference in percentage between previous and current value. (default 0x00006400 (0.1kWh and 0%)) + + + Conditions current usage will be automatically reported. Param 1-3: Difference in absolute value. Param 4: Difference in percentage between previous and current value. (default 0x0000050A (5Watt and 10%)) + + + Conditions current usage will be automatically reported. Param 1-3: Difference in absolute value. Param 4: Difference in percentage between previous and current value. (default 0x00006400 (0.1kWh and 0%)) + + + Conditions current delivered will be automatically reported. Param 1-3: Difference in absolute value. Param 4: Difference in percentage between previous and current value. (default 0x0000050A (5Watt and 10%)) + + + Conditions current delivered will be automatically reported. Param 1-3: Difference in absolute value. Param 4: Difference in percentage between previous and current value. (default 0x00006400 (0.1kWh and 0%)) + + + Conditions total used will be automatically reported. Param 1-3: Difference in absolute value. Param 4: Difference in percentage between previous and current value. (default 0x00006400 (0.1m3 and 0%)) + + + + + + + + + diff --git a/openzwave/BeNext/PanicButton.xml b/openzwave/BeNext/PanicButton.xml new file mode 100644 index 00000000..09d42633 --- /dev/null +++ b/openzwave/BeNext/PanicButton.xml @@ -0,0 +1,57 @@ + + + + + + Set all configuration values to default values (factory settings). + + + + The time that the panic pushbutton must be pressed before a (panic) message is sent out to the controller. + 0: send directly the panic message when pressed. + 1-255: send a panic message after you keep holding the button pressed for this value x 10ms. + + + + + Minimum time that led feedback is shown after a panic message. + 0: led only stays on during the send time. + 1-255: led stays on during send time + this value*10ms. + + + + + With this config parameter you can map the buttons to send different Z-Wave messages. + 0: SOS button sends an ALARM_REPORT to nodes group 1 LOCK button sends a BASIC_SET, 0xFF to nodes group 1 UNLOCK button sends a BASIC_SET, 0x00 to nodes group 1. + 1-255: button sends an BASIC_SET,0xFF to nodes group 1 LOCK button sends a BASIC_SET, 0xFF to nodes group 2 UNLOCK button sends a BASIC_SET, 0x00 to nodes group 2 + + + + + The time that the control pushbutton(s) must be pressed before a (control) message is sent out to the controller. + 0: send directly the panic message when pressed + 1-255: send a control message after you keep holding pushbutton pressed for this value x 10ms. + + + + + Minimum time that led feedback is shown after a control message is sent. + 0: led only stays on during the send time. + 1-255: led stays on during send time + this value*10ms. + + + + + + + true + + + + + + + + + + diff --git a/openzwave/BeNext/PanicWatch.xml b/openzwave/BeNext/PanicWatch.xml new file mode 100644 index 00000000..e05855da --- /dev/null +++ b/openzwave/BeNext/PanicWatch.xml @@ -0,0 +1,46 @@ + + + + + + Set all configuration values to default values (factory settings). + + + + The time that the panic pushbutton must be pressed before a (panic) message is sent out to the controller. + 0: send directly the panic message when pressed. + 1-255: send a panic message after you keep holding the button pressed for this value x 10ms. + + + + + Minimum time that led feedback is shown after a panic message. + 0: led only stays on during the send time. + 1-255: led stays on during send time + this value*10ms. + + + + + With this config parameter you can map the buttons to send different Z-Wave messages. + 0: SOS button sends an ALARM_REPORT to nodes group 1. + 1-255: SOS button sends an BASIC_SET, 0xFF to nodes group 1. + + + + + + + true + + + + + + + + + + diff --git a/openzwave/BeNext/PluginDimmer.xml b/openzwave/BeNext/PluginDimmer.xml new file mode 100644 index 00000000..68a725de --- /dev/null +++ b/openzwave/BeNext/PluginDimmer.xml @@ -0,0 +1,65 @@ + + + + + + + + Set all configuration values to default values (factory settings). + + + + The way the Built-in Dimmer reacts when light is turned on/off with button + + + + + + This parameter is used to enable the dimming option of the product. When disabled the dimming and fading routine are disabled. + + + + + + The maximum power load in watts when light is turned on, when measured higher then this value the Inline Dimmer is automatically turned off. + + + + The speed of dimming when activated (manual and RF). Dim speed is 1% per value (* 10 ms) + + + + The speed of fading up when activated (manual and RF). Fade speed is 1% per value (* 10 ms) + + + + A percentage that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 0% (disabled report) Maximum value = 100% + + + + A watt value that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 0 watt (disabled report) Maximum value = 255 watt + + + + A time value that has to be passed compared to a previous sent value before a unsolicited meter report is sent. Minimum value = 10 seconds Maximum value = 255 seconds + + + + What to do with lamp status when power applied. If 0x00: Always switch light off when power applied. If > 0x00: Switch lamp on/off depending on last known lampstatus before power was disconnected. + + + + The speed of fading up when activated (manual and RF). Fade speed is 1% per value (* 10 ms) + + + + + + + + + + + + + diff --git a/openzwave/BeNext/SceneController.xml b/openzwave/BeNext/SceneController.xml new file mode 100644 index 00000000..71987cc3 --- /dev/null +++ b/openzwave/BeNext/SceneController.xml @@ -0,0 +1,24 @@ + + + + + + + + Set all configuration values to default values (factory settings). + + + + The time that a user has to activate the double button pressed scene, if time is passed then the single pressed button scene is notified. + + + + + + + + + + + + diff --git a/openzwave/BeNext/TagReader.xml b/openzwave/BeNext/TagReader.xml new file mode 100644 index 00000000..edc5ce7d --- /dev/null +++ b/openzwave/BeNext/TagReader.xml @@ -0,0 +1,84 @@ + + + http://www.openzwave.com/device-database/008A:0100:0007 + images/BeNext/TagReader.png + https://products.z-wavealliance.org/products/43/ + info@benext.eu + http://www.benext.eu/en/products/tag-reader/ + CEPT (Europe) + Tag Reader + BeNext / TagReader + By reading your RFID-Tag or pressing a manual code you are able to arm or disarm your security system. The Tag Reader can read multiple RFID-tags protocols. With the sound of the buzzer you will easily hear and see if your action was valid. + +Place the Tag Reader close to the main exit of your office or home to enjoy it’s full potential. +With the Tag Reader you can activate or de-activate your security by simply passing the RFID Tag in front of the reader. It is called a Tag Reader because it uses RFID Tags to identify people and their personal preferences around leaving the house or coming home. + +Separately from working with RFID Tags, the Tag Reader also has a numerical keypad. Within the free of charge online manager you can configure a numerical code. This way you prevent being locked out of the system in case you may have lost the RFID Tag. + +By using the Tag Reader intelligently you can secure your house and save money on your energy bill at the same time. You can actually let your house ‘fall asleep’ when enabling the ‘Away Scene’. This is especially noted when u are using energy saving products of BeNext such as Radiator Control and of course a Energy Switch. +- The TagReader has the possibility for the user to manually insert codes. +- The TagReaders indicator light will react differently on each action. +- The TagReader has a buzzer, which can be used as walk-in/walk-out notification +(alarm is being disabled/activated). + +- arm/disarm a security system. +- Battery operated device for easy mounting on any place. +- Multiple tags support ISO15693, ISO18000-3, Tag-it™ +- Easy installation with NWI - get in control of your alarm system. + +The dimensions are 6 x 6 x 2 cm (LxBxH). The color of the product is traffic White, RAL 9016. +Switch between the scenes ‘Home’ and ‘Away’ easily and initiate security measures or instead de-activate them easily without use of complicated coding +• Let your house ‘wake up’ or instead ‘fall asleep’. This way you can save enormously on your energy bill +• Product dimensions: 62 x 62 x 20 millimeter (L x W x H) +• Normal operating voltage: 2x AA 1.5V batteries. From 2.3Vdc to 4.0Vdc. Do not use rechargeable batteries +• Battery lifetime: normal usage will give approximately a lifetime of 5 years. Notice: long and big networks will increase the battery lifetime +• Protocols supported: ISO15693, ISO18000-3, Tag-it™, RFID +• Buzzer-sound: approximately 60dB at 10 centimeters distance + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/43/xml + + + + + + Set all configuration values to default values (factory settings). + + + To configure the time the beep is automatically turned off in seconds. + + + + + To configure the timeout to wait for a WAKEUP_NO_MORE_INFORMATION before the error beep is automatically sound. The error beeps are fixed 8 beeps shortly after each other. + + + To configure the number of beeps per second. Every beep is fixed about 10ms. + + + To configure the operating mode. If any mode other then 3, that value will be reported after a get but will be handled in SW as mode 1. + + + + + The time (*10 ms) that the RFID circuit is started after home or away is pressed (default 100 = 100*10ms=1s) + + + + + + false + + + + + true + + + + + + + + + diff --git a/openzwave/BeNext/TagReader500.xml b/openzwave/BeNext/TagReader500.xml new file mode 100644 index 00000000..36914619 --- /dev/null +++ b/openzwave/BeNext/TagReader500.xml @@ -0,0 +1,83 @@ + + + http://www.openzwave.com/device-database/008A:0200:0007 + images/BeNext/TagReader500.png + https://products.z-wavealliance.org/products/2478/ + Tag Reader 500 US + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2478/Quickstart_Technical Manual_Tag_Reader500_US_v_0_12.pdf + The Tag Reader 500 US has an option to reset it self to factory settings. Please use this procedure only when the network primary controller is missing or otherwise inoperable. + +To reset to factory settings please follow these steps: +1. Press the enter button for 2 seconds, release the enter button to start the remove routine (indication LED will blink 3 times every second). +2. During the remove routine press enter button 4 times within 1,5 seconds to reset the product. +3. If ‘back to factory settings’ was successful the indication LED will go in for 1 full second on the end of the remove routine. +4. A DEVICE_RESET_LOCALLY_NOTIFICATION is sent to the nodes associated in the lifeline group. + To include the Tag Reader 500 US press and hold the enter button for two seconds (indication LED blinks shortly). Release the enter button now to start the inclusion (during the inclusion routine the indication LED willblink twice per second). + To exclude the Tag Reader 500 US press and hold the enter button for two seconds (indication LED blinks shortly). Release the enter button now to start the exclusion (during the exclusion routine the indication LED willblink twice three times per 1,5 second). + Press and hold the button fpr 7 seconds, the indication LED will go on for 1 full second. + A Z-Wave security enabled entry control device. You can arm/disarm your house to home or away with the Tag Reader 500. With the use of a RFID tag or a numerical code the device can send an entry control message which can be handled by a supported gateway. In addition the Tag Reader supports the activation of scenes. + 80820702 + CEPT (Europe) / U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1979/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2478/xml + + + + + + To configure the always awake mode. + + + + + To configure the time the beep is automatically turned off in seconds. + 0x00: Disable, 0x01 - 0xFE: Value in seconds + + + + + To configure the timeout to wait for a WAKEUP_NO_MORE_INFORMATION before the error beep + is automatically sound. The error beeps are fixed 8 beeps shortly after each other. + 0x00: Disabled, 0x01 - 0xFF: Value in seconds + + + + + To configure the number of beeps per second. Every beep is fixed about 10ms. + 0x00 - 0xFF: Number of beeps per second + + + + To configure the always awake mode. + + + + + The mode that the Tag Reader 500 communicates with the associated gateway. + + + + + + In gateway mode it is possible to let the gateway decide if the Tag Reader 500 can arm to home or away. + If gateway indication is disabled the Tag Reader 500 automatically assumes that it can arm and will wait + for a user input of RFID TAG or numeric code. + + + + + + + + + false + + + + + + + + + diff --git a/openzwave/BeNext/mydisplay.xml b/openzwave/BeNext/mydisplay.xml new file mode 100644 index 00000000..00055d54 --- /dev/null +++ b/openzwave/BeNext/mydisplay.xml @@ -0,0 +1,37 @@ + + + http://www.openzwave.com/device-database/008A:0100:0002 + images/BeNext/mydisplay.png + https://products.z-wavealliance.org/products/39/ + Remote Display + The Remote Display is a controlling device for changing automated lifestyles, selecting a scene or controlling individual products. The blue illuminated display provides comfortable readability during dark hours. +Two hotkey buttons are available which can be configured to your own wishes within the free of charge online manager. +The Remote Display runs on two AAA batteries, with an expected lifetime of four years. + +Features: +Control and manage different scenes easily from one controller +Easy to configure +Control individual products + +Specifications: +Z Cert Prod Pkg ExcpLogo W max Converted Remote Display +Product dimensions: 170 x 45 x 22 millimeter (L x W x H) +Normal operating voltage: 2x AAA 1,5V batteries. From 2,3Vdc to 4,0Vdc. Do not use rechargeable batteries +Storage temperature: -5°C to +65°C +Storage humidity: 10% to 70% +Operating temperature: 0°C to 50°C +Operating humidity: 30% to 80% +Frequency range: 868.42 MHz (Z-Wave) +Maximum wireless range: 100 meters in line of sight +Average wireless range: 30 meter +Mesh-network wireless range: 150 to 300 meters (maximum of 4 hops) + info@benext.eu + BeNext myDisplay + http://www.benext.eu/en/products/remote-display/ + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/39/xml + + + + diff --git a/openzwave/BeNext/mygate.xml b/openzwave/BeNext/mygate.xml new file mode 100644 index 00000000..c850f461 --- /dev/null +++ b/openzwave/BeNext/mygate.xml @@ -0,0 +1,20 @@ + + + http://www.openzwave.com/device-database/008A:0100:0001 + images/BeNext/mygate.png + https://products.z-wavealliance.org/products/53/ + BeNeXt / Internet Gateway + http://www.benext.eu/en/products/internet-gateway/ + info@Benext.eu + The Benext Internet Gateway is a static controller with Internet connection. +It is configured with lifestyles and rules for different scenes and operates with the BeNext Framework. + +Connect the Internet Gateway onto your Smart meter and start reading out data, completely independent from your local power supplier. The Gateway gives you access to our famed free of charge online manager. In this online environment you can, among many other features, set up energy targets, read out and compare revenues from installed solar panels and manage your use of gas. The more BeNext products you will use and install on the Gateway the better you’ll be able to automate big savings and broaden luxury and safety features. + Internet Gateway + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/53/xml + + + + diff --git a/openzwave/Localization.xml b/openzwave/Localization.xml new file mode 100644 index 00000000..695ae269 --- /dev/null +++ b/openzwave/Localization.xml @@ -0,0 +1,3418 @@ + + + + + + + + + A Smoke Alarm Alert + + Clear + Smoke Detected at Location + Smoke Detected at Unknown Location + Smoke Test + Replacement Required (Unspecified) + Replacement Required (End Of Life) + Silenced + Maintenance Required: Periodic Inspection + Maintenance Required: Dust In Device + Unknown Event + + + Carbon Monoxide Alerts + + Clear + Carbon Monoxide Detected at Location + Carbon Monoxide Detected at Unknown Location + Test + Replacement Required (Unspecified) + Replacement Required (End Of Life) + Silenced + Maintenance Required: Periodic Inspection + Unknown Event + + + Carbon Dioxide Alerts + + Clear + Carbon Dioxide Detected at Location + Carbon Dioxide Detected at Unknown Location + Test + Replacement Required (Unspecified) + Replacement Required (End Of Life) + Silenced + Maintenance Required: Periodic Inspection + Unknown Event + + + Heat Alerts + + Clear + OverHeat at Location + OverHeat at Unknown at Location + Rapid Temperature Rise at Location + Rapid Temperature Rise at Unknown Location + UnderHeat at Location + UnderHeat at Unknown Location + Test + Replacement Required (End_Of_Life) + Silenced + Maintenance Required: Dust In Device + Maintenance_Required: Periodic Inspection + Rapid temperature fall at Location + Rapid temperature fall at Unknown Location + Unknown Event + + + Water Alerts + + Clear + Water Leak at Location + Water Leak at Unknown Location + Water Level Dropped at Location + Water Level Dropped at Unknown Location + Replace Filter + Water Flow + Water Pressure + Water Temperature + Water Level + Sump Pump Active + Sump Pump Failure + Unknown Event + + + Access Control Alerts + + Clear + Manual Lock Operation + Manual Unlock Operation + Wireless Lock Operation + Wireless Unlock Operation + Keypad Lock Operation + Keypad Unlock Operation + Manual Lock Not Fully Locked + Wireless Not Fully Locked + Auto Lock + Auto Lock Not Fully Locked + Lock Jammed + All User Codes Deleted + Single User Code Deleted + New User Code Added + Duplicate User Code Not Added + Keypad Disabled + Keypad Busy + New Program Code Entered + User Codes Attempt Exceeds Limit + Wireless Unlock Invalid UserCode Entered + Wireless Lock Invalid UserCode Entered + Door/Window Open + Door/Window Closed + Window/door handle is open + Window/door handle is closed + Messaging User Code entered via keypa + Barrier Initializing + Barrier Force Exceeded + Barrier Motor Time Exceeded + Barrier Physical Limits Exceeded + Barrier Failed Operation + Barrier Unattended Operation Disabled + Barrier Malfunction + Barrier Vacation Mode + Barrier Safety Beam Obstruction + Barrier Sensor Not Detected + Barrier Sensor Battery Low + Barrier Short in Wall Station Wires + Barrier Associated with Non ZWave Device + Unknown Event + + + Home Security Alerts + + Clear + Intrusion at Location + Intrusion at Unknown Location + Tampering - Cover Removed + Tampering - Invalid Code + Glass Breakage at Location + Glass Breakage at UnknownLocation + Motion Detected at Location + Motion Detected at Unknown Location + Tampering - Product Moved + Impact detected + Magnetic field interference detected + Unknown Event + + + Power Management Alerts + + Clear + Power Applied + AC Power Lost + AC Power Restored + Surge Detected + Brownout Detected + Over Current Detected + Over Voltage Detected + Over Load Detected + Load Error + Replace Battery Soon + Replace Battery Now + Battery Charging + Battery Charged + Battery Low + Battery Critical + Back-up battery is low + Back-up battery disconnected + Unknown Event + + + System Alerts + + Clear + Hardware Failure + Software Failure + Hardware Failure Code + Software Failure Code + Heartbeat + Tampering Detected + Emergency Shutoff + Digital input high state + Digital input low state + Digital input open + Unknown Event + + + Emergency Alerts + + Clear + Contact Police Department + Contact Fire Department + Contact Medical Service + Panic alert + Unknown Event + + + Clock Alerts + + Clear + Wake Up Alert + Timer Ending + Time Remaining + Unknown Event + + + Appliance Alerts + + Clear + Program Started + Program In Progress + Program Completed + Replace Main Filter + Failure To Set Temperature + Supplying Water + Water Supply Failure + Boiling + Boiling Failure + Washing + Washing Failure + Rinsing + Rinsing Failure + Draining + Draining Failure + Spinning + Spinning Failure + Drying + Drying Failure + Fan Failure + Compressor Failure + Unknown Event + + + Home Health Alerts + + Clear + Leaving Bed + Sitting On Bed + Lying On Bed + Posture Changed + Sitting On Edge Of Bed + Volatile Organic Compound Level + Sleep apnea detected + Sleep stage 0 detected (Dreaming/REM) + Sleep stage 1 detected (Light sleep, non-REM 1) + Sleep stage 2 detected (Medium sleep, non-REM 2) + Sleep stage 3 detected (Deep sleep, non-REM 3) + Unknown Event + + + Siren Alerts + + Clear + Active + Unknown Event + + + Water Valve Alerts + + Clear + Valve Operation + Master Valve Operation + Valve Short Circuit + Master Valve Short Circuit + Valve Current Alarm + Master Valve Current Alarm + Unknown Event + + + Weather Alerts + + Clear + Rain Detected + Moisture Detected + Freeze + Unknown Event + + + Irrigation Alerts + + Clear + Schedule Started + Schedule Finished + Valve Table Run Started + Valve Table Run Finished + Device Not Configured + Unknown Event + + + Gas Alerts + + Clear + Combustable Gas Detected at Location + Combustable Gas Detected at Unknown Location + Toxic Gas Detected at Location + Toxic Gas Detected Unknown Location + Alarm Test + Replacement Required + Unknown Event + + + Pest Control Alerts + + Clear + Trap armed at Location + Trap armed + Trap re-arm required at Location + Trap re-arm required + Pest detected at Location + Pest detected + Pest exterminated at Location + Pest exterminated + Unknown Event + + + Light Alerts + + Clear + Light detected + Light color transition detected + Unknown Event + + + Water Quality Monitoring Alerts + + Clear + Chlorine + Acidity (pH) + Water Oxidation + Chlorine empty + Acidity (pH) empty + Waterflow measuring station shortage detected + Waterflow clear water shortage detected + Disinfection system error detected + Filter cleaning ongoing + Heating operation ongoing + Filter pump operation ongoing + Freshwater operation ongoing + Dry protection operation active + Water tank is empty + Water tank level is unknow + Water tank is full + Collective disorder + Unknown Event + + + Home Monitoring Alerts + + Clear + Home occupied at Location + Home occupied + Unknown Event + + + + + Previous Event that was sent + + + + Location that the Alert was detected at + + + + Result of the Test + + Passed + Failed + + + Threshold Exceeded for Alert + + No Data + Below Low Threshold + Above High Threshold + Max + + + + User Code ID that was used + + + + User Code that was used + + + + Progress of Operation + + Process Complete + Performing Process + + + Enabled Mode + + Disabled + Enabled + + + The status of the obstruction + + No Obstruction + Obstruction + + + The ID of the Sensor that triggered the alert + + + + The Error Code returned by the device + + + + Duration remaining in seconds + + + + The Pollution Level Detected + + Clean + Slightly Polluted + Moderately Polluted + Highly Polluted + + + The Status of the Device + + Off + On + + + The ID of the Schedule that triggered this alert + + + + The ID of the Valve Table that triggered this alert + + + + Detected Power of interference + + + + Alarm Type Received + Type d'alarme reçu + + + + + Alarm Level Received + Niveau d'alarme reçu + + + + + Automatically Clear Events sent by a device after a number of Milliseconds + + + + + + + + + + + + + Maximum Command Length that can be stored on this node + + + + True - Only Basic Set Messages are stored. False - Full Commands may be stored + + + + A Application can configure the commands sent + + + + The Amount of free commands that can be stored + + + + The Maximum Number of commands that can be stored + + + + + + + The Current State of the Barrier + + + + Supported Operations for the Barrier + + + + Enable Audible Notifications of Barrier State Change + + + + Enable Visual Notifications of Barrier State Change + + + + + + + + Basic status of the node + Basic status of the node in French + + + + + + + + Open the Window Covering + + + + Close the Window Covering + + + + + + + Current Battery Level + + + + + + + + + + Schedule + + + + Schedule for Monday + + + + Schedule for Tuesday + + + + Schedule for Wednesday + + + + Schedule for Thursday + + + + Schedule for Friday + + + + Schedule for Saturday + + + + Schedule for Sunday + + + + Override Schedule + + + + Override Setback + + + + + + + Day of Week + + + + Hour + + + + Minute + + + + + + + Color (in RGB format) + + + + Preset Color + + + + Color Capabilities of the device + + + + Duration to change colors (Values above 7620 use the devices default duration) + + + + + + + + + + + Node to Perform the replication with + + + + What Features should be replicated + + + + Start the Replication + + + + + + + + + + + + + State of the Lock + + + + State of the Lock (Advanced) + + + + Timeout Mode for Reverting Lock State + + + + How Many Minutes before reverting Lock State + + + + How Many Seconds before reverting Lock State + + + + State of the Exterior Handle Control + + + + State of the Interior Handle Control + + + + + + + Max Number of Logging Records Stored + + + + Current Log Record Number + + + + Log Entry + + + + + + + Current Energy Production Value + + + + Total Amount of Energy Produced + + + + Total Amount of Energy Produced Today + + + + Total Time Producing Energy + + + + + + + + + + Current Indicator State + + + + Use to indicate that alarm is armed + + + + Use to indicate that alarm is disarmed + + + + Use to indicate that device is ready + + + + Use to indicate a general error + + + + Use to indicate that device is temporarily busy + + + + Use to signal that device is waiting for ID + + + + Use to signal that device is waiting for PIN code + + + + Use to indicate OK e.g. the entered code is accepted + + + + Use to indicate NOT OK e.g. the entered code is NOT accepted + + + + Use to indicate that the alarm is armed and users are staying in the home + + + + Use to indicate that the alarm is armed and users are away from the home + + + + Use to indicate that the alarm is triggered and active with no reason specified + + + + Use to indicate that the alarm is triggered and active due to a Burglar event + + + + Use to indicate that the alarm is triggered and active due to a Fire Alarm event + + + + Use to indicate that the alarm is triggered and active due to a CO event + + + + Use to indicate that the device expects a bypass challenge code + + + + Use to indicate that the alarm is about to be activated unless disarmed by a code + + + + Use to indicate that the alarm will be active after the exit delay + + + + Use to indicate that the alarm is triggered and active due to a medical emergency + + + + Use to indicate that the alarm is triggered and active due to a freeze warning + + + + Use to indicate that the alarm is triggered and active due to a water leak + + + + Use to indicate that the alarm is triggered and active due to a panic alarm trigger + + + + Use to indicate that alarm zone 1 is armed + + + + Use to indicate that alarm zone 2 is armed + + + + Use to indicate that alarm zone 3 is armed + + + + Use to indicate that alarm zone 4 is armed + + + + Use to indicate that alarm zone 5 is armed + + + + Use to indicate that alarm zone 6 is armed + + + + Use to indicate that alarm zone 7 is armed + + + + Use to indicate that alarm zone 8 is armed + + + + Use to turn on LCD backlight, e.g. to shortly draw attention when alarm is activated from another entry control keypad. + + + + Use to indicate that buttons are ready for user input + + + + Use to indicate that buttons are ready for user input + + + + Use to indicate that buttons are ready for user input + + + + Use to draw attention to button 1 + + + + Use to draw attention to button 2 + + + + Use to draw attention to button 3 + + + + Use to draw attention to button 4 + + + + Use to draw attention to button 5 + + + + Use to draw attention to button 6 + + + + Use to draw attention to button 7 + + + + Use to draw attention to button 8 + + + + Use to draw attention to button 9 + + + + Use to draw attention to button 10 + + + + Use to draw attention to button 11 + + + + Use to draw attention to button 12 + + + + This indicator is used to identify the node. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Sound indication, use to indicate that a generic event happened. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Manufacturer Defined. + + + + Use to draw attention or provide user feedback + + + + + + + + Current Language Setting of the Device is ISO639-2 Format + + + + Current Country Setting of the Device in IS3166-1 Format + + + + + + + Current State of the Device + + + + + + + + + + Revision of the Config file currently loaded + + + + Revision of the Config file on the File System + + + + Latest Revision of the Config file available for download + + + + Manufacturer Specific Device ID/Model + + + + Device Serial Number + + + + + + + Electric Kilowatt Hour Reading + + + + Electric Kilo Volt Amperes Hours Reading + + + + Electric Watts Reading + + + + Electric Pulses Reading + + + + Electric Volts Reading + + + + Electric Amps Reading + + + + Electric Power Factor Reading + + + + Electric Kilovolt-amperes Reactive Reading + + + + Electric Kilo Volt Amps Reactive Hours Reading + + + + Gas Cubic Meters Reading + + + + Gas Cubic Feet Reading + + + + Gas Pulses Reading + + + + Water Cubic Meters Reading + + + + Water Cubic Feet Reading + + + + Water US Gallons Reading + + + + Water Pulses Reading + + + + Heating kWh Reading + + + + Cooling kWh Reading + + + + + + + Number of Pulses sent by the Meter + + + + + + + + + + + + + + + + + + + + + + Output RF PowerLevel + + Normal + -1dB + -2dB + -3dB + -4dB + -5dB + -6dB + -7dB + -8dB + -9dB + unknown + + + Timeout till the PowerLevel is reset to Normal + + + + Apply the Output PowerLevel and Timeout Values + + + + Node to Perform a test against + + + + PowerLevel to use for the Test + + + + How Many Messages to send to the Node for the Test + + + + Perform a PowerLevel Test against the a Node + + + + Get the results of the latest PowerLevel Test against a Node + + + + The Current Status of the last PowerNode Test Executed + + + + Number of Messages successfully Acked by the Target Node + + + + + + + + + + Protect a device against unintentional control + + + + + + + + + + Is Communication with Device Encrypted + + + + + + + General Alarm + + + + Smoke Alarm + + + + Carbon Monoxide Alarm + + + + Carbon Dioxide Alarm + + + + Heat Alarm + + + + Flood Alarm + + + + + + + Binary Sensor State + + + + + + + Air Temperature Sensor Value + + + + General Purpose Sensor Value + + + + Luminance Sensor Value + + + + Power Sensor Value + + + + Humidity Sensor Value + + + + Velocity Sensor Value + + + + Direction Sensor Value + + + + Atmospheric Pressure Sensor Value + + + + Barometric Pressure Sensor Value + + + + Solar Radiation Sensor Value + + + + Dew Point Sensor Value + + + + Rain Rate Sensor Value + + + + Tide Level Sensor Value + + + + Weight Sensor Value + + + + Voltage Sensor Value + + + + Current Sensor Value + + + + Carbon Dioxide Sensor Value + + + + Air Flow Sensor Value + + + + Tank Capacity Sensor Value + + + + Distance Sensor Value + + + + Angle Position Sensor Value + + + + Rotation Sensor Value + + + + Water Temperature Sensor Value + + + + Soil Temperature Sensor Value + + + + Seismic Intensity Sensor Value + + + + Seismic Magnitude Sensor Value + + + + Ultraviolet Sensor Value + + + + Electrical Resistivity Sensor Value + + + + Electrical Conductivity Sensor Value + + + + Loudness Sensor Value + + + + Moisture Sensor Value + + + + Frequency Sensor Value + + + + Time Sensor Value + + + + Target Temperature Sensor Value + + + + Particulate Matter 2.5 Sensor Value + + + + Formaldehyde CH20 Level Sensor Value + + + + Radon Concentration Sensor Value + + + + Methane Density Sensor Value + + + + Volatile Organic Compound Sensor Value + + + + Carbon Monoxide Sensor Value + + + + Soil Humidity Sensor Value + + + + Soil Reactivity Sensor Value + + + + Soil Salinity Sensor Value + + + + Heart Rate Sensor Value + + + + Blood Pressure Sensor Value + + + + Muscle Mass Sensor Value + + + + Fat Mass Sensor Value + + + + Bone Mass Sensor Value + + + + Total Body Water Sensor Value + + + + Basic Metabolic Rate Sensor Value + + + + Body Mass Index Sensor Value + + + + X-Axis Acceleration Sensor Value + + + + Y-Axis Acceleration Sensor Value + + + + Z-Axis Acceleration Sensor Value + + + + Smoke Density Sensor Value + + + + Water Flow Sensor Value + + + + Water Pressure Sensor Value + + + + RF Signal Strength Sensor Value + + + + Particulate Matter Sensor Value + + + + Respiratory Rate Sensor Value + + + + Relative Modulation Sensor Value + + + + Boiler Water Temperature Sensor Value + + + + Domestic Hot Water Temperature Sensor Value + + + + Outside Temperature Sensor Value + + + + Exhaust Temperature Sensor Value + + + + Water Chlorine Sensor Value + + + + Water Acidity Sensor Value + + + + Water Oxidation Reduction Potential Sensor Value + + + + Heart Rate LF/HF Ratio Sensor Value + + + + Motion Direction Sensor Value + + + + Applied Force Sensor Value + + + + Return Air Temperature Sensor Value + + + + Supply Air Temperature Sensor Value + + + + Condenser Coil Temperature Sensor Value + + + + Evaporator Coil Temperature Sensor Value + + + + Liquid Line Temperature Sensor Value + + + + Discharge Line Temperature Sensor Value + + + + Suction Sensor Value + + + + Discharge Sensor Value + + + + Defrost Temperature Sensor Value + + + + Ozone Sensor Value + + + + Sulfur Dioxide Sensor Value + + + + Nitrogen Dioxide Sensor Value + + + + Ammonia Sensor Value + + + + Lead Sensor Value + + + + Particulate Matter Sensor Value + + + + Air Temperature Sensor Available Units + + + + General Purpose Sensor Available Units + + + + Luminance Sensor Available Units + + + + Power Sensor Available Units + + + + Humidity Sensor Available Units + + + + Velocity Sensor Available Units + + + + Direction Sensor Available Units + + + + Atmospheric Pressure Sensor Available Units + + + + Barometric Pressure Sensor Available Units + + + + Solar Radiation Sensor Available Units + + + + Dew Point Sensor Available Units + + + + Rain Rate Sensor Available Units + + + + Tide Level Sensor Available Units + + + + Weight Sensor Available Units + + + + Voltage Sensor Available Units + + + + Current Sensor Available Units + + + + Carbon Dioxide Sensor Available Units + + + + Air Flow Sensor Available Units + + + + Tank Capacity Sensor Available Units + + + + Distance Sensor Available Units + + + + Angle Position Sensor Available Units + + + + Rotation Sensor Available Units + + + + Water Temperature Sensor Available Units + + + + Soil Temperature Sensor Available Units + + + + Seismic Intensity Sensor Available Units + + + + Seismic Magnitude Sensor Available Units + + + + Ultraviolet Sensor Available Units + + + + Electrical Resistivity Sensor Available Units + + + + Electrical Conductivity Sensor Available Units + + + + Loudness Sensor Available Units + + + + Moisture Sensor Available Units + + + + Frequency Sensor Available Units + + + + Time Sensor Available Units + + + + Target Temperature Sensor Available Units + + + + Particulate Matter 2.5 Sensor Available Units + + + + Formaldehyde CH20 Level Sensor Available Units + + + + Radon Concentration Sensor Available Units + + + + Methane Density Sensor Available Units + + + + Volatile Organic Compound Sensor Available Units + + + + Carbon Monoxide Sensor Available Units + + + + Soil Humidity Sensor Available Units + + + + Soil Reactivity Sensor Available Units + + + + Soil Salinity Sensor Available Units + + + + Heart Rate Sensor Available Units + + + + Blood Pressure Sensor Available Units + + + + Muscle Mass Sensor Available Units + + + + Fat Mass Sensor Available Units + + + + Bone Mass Sensor Available Units + + + + Total Body Water Sensor Available Units + + + + Basic Metabolic Rate Sensor Available Units + + + + Body Mass Index Sensor Available Units + + + + X-Axis Acceleration Sensor Available Units + + + + Y-Axis Acceleration Sensor Available Units + + + + Z-Axis Acceleration Sensor Available Units + + + + Smoke Density Sensor Available Units + + + + Water Flow Sensor Available Units + + + + Water Pressure Sensor Available Units + + + + RF Signal Strength Sensor Available Units + + + + Particulate Matter Sensor Available Units + + + + Respiratory Rate Sensor Available Units + + + + Relative Modulation Sensor Available Units + + + + Boiler Water Temperature Sensor Available Units + + + + Domestic Hot Water Temperature Sensor Available Units + + + + Outside Temperature Sensor Available Units + + + + Exhaust Temperature Sensor Available Units + + + + Water Chlorine Sensor Available Units + + + + Water Acidity Sensor Available Units + + + + Water Oxidation Reduction Potential Sensor Available Units + + + + Heart Rate LF/HF Ratio Sensor Available Units + + + + Motion Direction Sensor Available Units + + + + Applied Force Sensor Available Units + + + + Return Air Temperature Sensor Available Units + + + + Supply Air Temperature Sensor Available Units + + + + Condenser Coil Temperature Sensor Available Units + + + + Evaporator Coil Temperature Sensor Available Units + + + + Liquid Line Temperature Sensor Available Units + + + + Discharge Line Temperature Sensor Available Units + + + + Suction Sensor Available Units + + + + Discharge Sensor Available Units + + + + Defrost Temperature Sensor Available Units + + + + Ozone Sensor Available Units + + + + Sulfur Dioxide Sensor Available Units + + + + Nitrogen Dioxide Sensor Available Units + + + + Ammonia Sensor Available Units + + + + Lead Sensor Available Units + + + + Particulate Matter Sensor Available Units + + + + + + + The Number of Available Tones on the Node + + + + A List of Available Tones on the Device + + + + The Volume to play the tone at + + + + The default tone to play when none is specified in a Play Command + + + + + + + Switch All Devices On/Off + + + + + + + Turn On/Off Device + + + + The Final State of the Switch + + + + How Long to Transition to new State (Values above 7620 use the devices default duration) + + + + + + + The Current Level of the Device + + + + Increase the Brightness of the Device + + + + Decrease the Brightness of the Device + + + + Ignore the Start Level of the Device when increasing/decreasing brightness + + + + Start Level when Changing the Brightness of a Device + + + + Duration taken when changing the Level of a Device (Values above 7620 use the devices default duration) + + + + How Many Percent Change when incrementing/decrementing the Level of a Device + + + + Increment the Level of a Device + + + + Decrement the Level of a Device + + + + + + + Turn On/Off a Device + + + + + + + Set the Device to a Level + + + + + + + Set the Fan Mode + + + + + + + Set the Fan State + + + + + + + Set the Thermostat Mode + + + + + + + Set the Thermostat Operating State + + + + + + + Set the Thermostat Setpoint Unused 0 + + + + Set the Thermostat Setpoint Heating 1 + + + + Set the Thermostat Setpoint Cooling 1 + + + + Set the Thermostat Setpoint Unused 3 + + + + Set the Thermostat Setpoint Unused 4 + + + + Set the Thermostat Setpoint Unused 5 + + + + Set the Thermostat Setpoint Unused 6 + + + + Set the Thermostat Setpoint Furnace + + + + Set the Thermostat Setpoint Dry Air + + + + Set the Thermostat Setpoint Moist Air + + + + Set the Thermostat Setpoint Auto Changeover + + + + Set the Thermostat Setpoint Heating Econ + + + + Set the Thermostat Setpoint Cooling Econ + + + + Set the Thermostat Setpoint Away Heating + + + + Set the Thermostat Setpoint Away Cooling + + + + Set the Thermostat Setpoint Full Power + + + + + + + + Current Date + + + + Current Time + + + + Set the Date/Time + + + + Refresh the Date/Time + + + + + + + Enrollment Code + + + + UserCode 1 + + + + UserCode 2 + + + + UserCode 3 + + + + UserCode 4 + + + + UserCode 5 + + + + UserCode 6 + + + + UserCode 7 + + + + UserCode 8 + + + + UserCode 9 + + + + UserCode 10 + + + + UserCode 11 + + + + UserCode 12 + + + + UserCode 13 + + + + UserCode 14 + + + + UserCode 15 + + + + UserCode 16 + + + + UserCode 17 + + + + UserCode 18 + + + + UserCode 19 + + + + UserCode 20 + + + + UserCode 21 + + + + UserCode 22 + + + + UserCode 23 + + + + UserCode 24 + + + + UserCode 25 + + + + UserCode 26 + + + + UserCode 27 + + + + UserCode 28 + + + + UserCode 29 + + + + UserCode 30 + + + + UserCode 31 + + + + UserCode 32 + + + + UserCode 33 + + + + UserCode 34 + + + + UserCode 35 + + + + UserCode 36 + + + + UserCode 37 + + + + UserCode 38 + + + + UserCode 39 + + + + UserCode 40 + + + + UserCode 41 + + + + UserCode 42 + + + + UserCode 43 + + + + UserCode 44 + + + + UserCode 45 + + + + UserCode 46 + + + + UserCode 47 + + + + UserCode 48 + + + + UserCode 49 + + + + UserCode 50 + + + + UserCode 51 + + + + UserCode 52 + + + + UserCode 53 + + + + UserCode 54 + + + + UserCode 55 + + + + UserCode 56 + + + + UserCode 57 + + + + UserCode 58 + + + + UserCode 59 + + + + UserCode 60 + + + + UserCode 61 + + + + UserCode 62 + + + + UserCode 63 + + + + UserCode 64 + + + + UserCode 65 + + + + UserCode 66 + + + + UserCode 67 + + + + UserCode 68 + + + + UserCode 69 + + + + UserCode 70 + + + + UserCode 71 + + + + UserCode 72 + + + + UserCode 73 + + + + UserCode 74 + + + + UserCode 75 + + + + UserCode 76 + + + + UserCode 77 + + + + UserCode 78 + + + + UserCode 79 + + + + UserCode 80 + + + + UserCode 81 + + + + UserCode 82 + + + + UserCode 83 + + + + UserCode 84 + + + + UserCode 85 + + + + UserCode 86 + + + + UserCode 87 + + + + UserCode 88 + + + + UserCode 89 + + + + UserCode 90 + + + + UserCode 91 + + + + UserCode 92 + + + + UserCode 93 + + + + UserCode 94 + + + + UserCode 95 + + + + UserCode 96 + + + + UserCode 97 + + + + UserCode 98 + + + + UserCode 99 + + + + UserCode 100 + + + + UserCode 101 + + + + UserCode 102 + + + + UserCode 103 + + + + UserCode 104 + + + + UserCode 105 + + + + UserCode 106 + + + + UserCode 107 + + + + UserCode 108 + + + + UserCode 109 + + + + UserCode 110 + + + + UserCode 111 + + + + UserCode 112 + + + + UserCode 113 + + + + UserCode 114 + + + + UserCode 115 + + + + UserCode 116 + + + + UserCode 117 + + + + UserCode 118 + + + + UserCode 119 + + + + UserCode 120 + + + + UserCode 121 + + + + UserCode 122 + + + + UserCode 123 + + + + UserCode 124 + + + + UserCode 125 + + + + UserCode 126 + + + + UserCode 127 + + + + UserCode 128 + + + + UserCode 129 + + + + UserCode 130 + + + + UserCode 131 + + + + UserCode 132 + + + + UserCode 133 + + + + UserCode 134 + + + + UserCode 135 + + + + UserCode 136 + + + + UserCode 137 + + + + UserCode 138 + + + + UserCode 139 + + + + UserCode 140 + + + + UserCode 141 + + + + UserCode 142 + + + + UserCode 143 + + + + UserCode 144 + + + + UserCode 145 + + + + UserCode 146 + + + + UserCode 147 + + + + UserCode 148 + + + + UserCode 149 + + + + UserCode 150 + + + + UserCode 151 + + + + UserCode 152 + + + + UserCode 153 + + + + UserCode 154 + + + + UserCode 155 + + + + UserCode 156 + + + + UserCode 157 + + + + UserCode 158 + + + + UserCode 159 + + + + UserCode 160 + + + + UserCode 161 + + + + UserCode 162 + + + + UserCode 163 + + + + UserCode 164 + + + + UserCode 165 + + + + UserCode 166 + + + + UserCode 167 + + + + UserCode 168 + + + + UserCode 169 + + + + UserCode 170 + + + + UserCode 171 + + + + UserCode 172 + + + + UserCode 173 + + + + UserCode 174 + + + + UserCode 175 + + + + UserCode 176 + + + + UserCode 177 + + + + UserCode 178 + + + + UserCode 179 + + + + UserCode 180 + + + + UserCode 181 + + + + UserCode 182 + + + + UserCode 183 + + + + UserCode 184 + + + + UserCode 185 + + + + UserCode 186 + + + + UserCode 187 + + + + UserCode 188 + + + + UserCode 189 + + + + UserCode 190 + + + + UserCode 191 + + + + UserCode 192 + + + + UserCode 193 + + + + UserCode 194 + + + + UserCode 195 + + + + UserCode 196 + + + + UserCode 197 + + + + UserCode 198 + + + + UserCode 199 + + + + UserCode 200 + + + + UserCode 201 + + + + UserCode 202 + + + + UserCode 203 + + + + UserCode 204 + + + + UserCode 205 + + + + UserCode 206 + + + + UserCode 207 + + + + UserCode 208 + + + + UserCode 209 + + + + UserCode 210 + + + + UserCode 211 + + + + UserCode 212 + + + + UserCode 213 + + + + UserCode 214 + + + + UserCode 215 + + + + UserCode 216 + + + + UserCode 217 + + + + UserCode 218 + + + + UserCode 219 + + + + UserCode 220 + + + + UserCode 221 + + + + UserCode 222 + + + + UserCode 223 + + + + UserCode 224 + + + + UserCode 225 + + + + UserCode 226 + + + + UserCode 227 + + + + UserCode 228 + + + + UserCode 229 + + + + UserCode 230 + + + + UserCode 231 + + + + UserCode 232 + + + + UserCode 233 + + + + UserCode 234 + + + + UserCode 235 + + + + UserCode 236 + + + + UserCode 237 + + + + UserCode 238 + + + + UserCode 239 + + + + UserCode 240 + + + + UserCode 241 + + + + UserCode 242 + + + + UserCode 243 + + + + UserCode 244 + + + + UserCode 245 + + + + UserCode 246 + + + + UserCode 247 + + + + UserCode 248 + + + + UserCode 249 + + + + UserCode 250 + + + + UserCode 251 + + + + UserCode 252 + + + + UserCode 253 + + + + UserCode 253 + + + + UserCode 254 + + + + Refresh All UserCodes Stored on Device + + + + Remove A UserCode at the Specified Index + + + + Number of User Codes supported by the Device + + + + The Raw UserCode as specified at the Position in Raw UserCode Index + + + + Get the Raw User Code for the Index Specified in this value + + + + + + + Z-Wave Library Version + + + + Z-Wave Protocol Version + + + + Application Version + + + + + + + How often the Device will Wake up to check for pending commands + + + + Minimum Time in seconds the device will wake up + + + + Maximum Time in seconds the device will wake up + + + + The Default Wake-Up Interval the device will wake up + + + + Step Size on Wake-up interval + + + + + + + ZWave+ Version Supported on the Device + + + + Icon File to use for the Installer Application + + + + Icon File to use for the User Application + + + + + + + + diff --git a/openzwave/Localization.xsd b/openzwave/Localization.xsd new file mode 100644 index 00000000..5b7302ed --- /dev/null +++ b/openzwave/Localization.xsd @@ -0,0 +1,69 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/NotificationCCTypes.xml b/openzwave/NotificationCCTypes.xml new file mode 100644 index 00000000..b0dbb1ac --- /dev/null +++ b/openzwave/NotificationCCTypes.xml @@ -0,0 +1,730 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/NotificationCCTypes.xsd b/openzwave/NotificationCCTypes.xsd new file mode 100644 index 00000000..0c71029a --- /dev/null +++ b/openzwave/NotificationCCTypes.xsd @@ -0,0 +1,64 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/SensorMultiLevelCCTypes.xml b/openzwave/SensorMultiLevelCCTypes.xml new file mode 100644 index 00000000..17e65afa --- /dev/null +++ b/openzwave/SensorMultiLevelCCTypes.xml @@ -0,0 +1,318 @@ + + + + C + F + + + % + + + + + % + Lux + + + W + Btu/h + + + % + g/m3 + + + m/s + Mph + + + ° + + + kPa + inHg + + + kPa + inHg + + + W/m2 + + + C + F + + + mm/h + in/h + + + m + ft + + + Kg + lb + + + V + mV + + + A + mA + + + Ppm + + + M3/h + cfm + + + l + M3 + gal + + + m + cm + ft + + + % + + + + + rpm + Hz + + + C + F + + + C + F + + + MM + EMS + Liedu + Shindo + + + Ml + Mw + Ms + Mb + + + UV + + + Ωm + + + S⋅m-1 + + + dB + dBA + + + % + M3/m3 + + aw + + + Hz + kHz + + + s + + + C + F + + + mol/m3 + μg/m3 + + + mol/m3 + + + bq/m3 + pCi/L + + + mol/m3 + + + mol/m3 + Ppm + + + mol/m3 + Ppm + + + % + + + pH + + + mol/m3 + + + Bpm + + + mmHg + mmHg + + + Kg + + + Kg + + + Kg + + + Kg + + + J + + + BMI + + + m/s2 + + + m/s2 + + + m/s2 + + + % + + + l/h + + + kPa + + + RSSI + dBm + + + mol/m3 + μg/m3 + + + Bpm + + + % + + + C + F + + + C + F + + + C + F + + + C + F + + + mg/l + + + pH + + + mV + + + + + + degrees + + + N + + + C + F + + + C + F + + + C + F + + + C + F + + + C + F + + + C + F + + + kPa + psi + + + kPa + psi + + + C + F + + + μg/m3 + + + μg/m3 + + + μg/m3 + + + μg/m3 + + + μg/m3 + + + μg/m3 + + diff --git a/openzwave/SensorMultiLevelCCTypes.xsd b/openzwave/SensorMultiLevelCCTypes.xsd new file mode 100644 index 00000000..cc284f94 --- /dev/null +++ b/openzwave/SensorMultiLevelCCTypes.xsd @@ -0,0 +1,30 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/abus/SHRM10000.xml b/openzwave/abus/SHRM10000.xml new file mode 100644 index 00000000..acbc8c4c --- /dev/null +++ b/openzwave/abus/SHRM10000.xml @@ -0,0 +1,40 @@ + + + http://www.openzwave.com/device-database/0403:0003:0002 + images/abus/SHRM10000.jpg + https://products.z-wavealliance.org/products/3089/ + The Smart Smoke Alarm adopts Z-Wave protocol, when the sensor detects smoke to the set level, it will issue acoustic-optic alarm to alert the users and also send alarm notifications to gateway immediately.It's suitable to be installed in living room, office,warehouse,and etc. + - Click [Add] icon in Z-Wave Controller . +- Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second. +- If Inclusion Process is successful, Green led will turn off. + + - Click [Remove] icon in Z-Wave Controller +- Press the Net_Button 3 times within 1.5s +- If Exclusion Process is successful, Green led is Blinking 6 times, then turn off. + + - Wake up Notification is transmitted every 24 hours by default. +- Wake up Notification is transmitted after Notification Report is Transmitted + --Long press Net_Button while installing batteries in the product. +- Device Reset Locally notification is Transmitted. +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + HS1SA-Z + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3006/HS1SA-Z S2-documentation_3.pdf + Smart Smoke Alarm + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3089/xml + + + + + + + + + + + diff --git a/openzwave/act/lfm20.xml b/openzwave/act/lfm20.xml new file mode 100644 index 00000000..bb598f8a --- /dev/null +++ b/openzwave/act/lfm20.xml @@ -0,0 +1,28 @@ + + + http://www.openzwave.com/device-database/0001:3133:5246 + images/act/lfm20.png + https://products.z-wavealliance.org/products/134/ + ZRF113 - Isolated Contact Fixture Module + http://www.act-solutions.com/Contact-Advanced-Control-Technologies.html + U.S. / Canada / Mexico + ZRF113 + http://www.act-solutions.com/HomePro-Product-Matrix.html#Euro + - The relay on this device is isolated from the power line, so it can be used to switch any load, including low voltage. This can be used in areas where an X10 universal module may have been used. + +- The LED on the ZRF113 will turn on when the load attached is ON. The LED is user configured however to turn ON when the load attached is OFF, if so desired. + +- The ZRF113 supports the AS101 and AS001 auxiliary switch. + +- Max load 20 amps. + +- Supports Z-Wave 40Kbps speed + +- Signal (Frequency): 908.42 MHz + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/134/xml + + + + + diff --git a/openzwave/act/zdm230.xml b/openzwave/act/zdm230.xml new file mode 100644 index 00000000..2eba5a3a --- /dev/null +++ b/openzwave/act/zdm230.xml @@ -0,0 +1,112 @@ + + + http://www.openzwave.com/device-database/0001:3330:444D + images/act/zdm230.png + https://products.z-wavealliance.org/products/478/ + ZDM230 - Dual button Wall Dimmer + CEPT (Europe) + The ZDM230 is a dual switch design, where the first switch controls the connected load and also serve as a transmitter using multiple switch taps (one group of 5 Z-Wave modules), and the second switch used as a transmitter only (controls two groups of 5 Z-Wave modules). + +ZDM230 replaces an existing wall switch, and can add 3-way capability. + +ZDM230 can be programmed as a routing slave to establish firm signal routes and can be "associated" with other Z-wave devices in order to control them. + +ZDM230 has automatic Static Update Controller (SUC) capability. A Static Controller is one that is not moved after its addition to the network. The Static Controller can act as a gateway in the system, since other nodes always know its position. The “always listening” advantage of the Static Controller is that other nodes can transmit information frames to it whenever needed. + +ZDM230 can be configured to Control Shades or Window Coverings via Z-Wave network + ZDM230 + http://www.smarthome-products.com/p-638-homepro-zdm230-z-wave-500-watt-dimmer-3-way-3-wire-euro.aspx + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/478/xml + + + + + + Dimmers controlled by this switch will start dimming from their current level. + + + + + Disable transmitting commands to Z-Wave devices that are in Group 4 without disassociating those devices from the group. + + + + + In night-light mode the LED on the switch will turn ON when the switch is turned OFF. + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch. + + + + + This dimmer will start dimming from its current level. + + + + + When you press and hold the bottom of the ZDM230 switch once, the Z-Wave devices that are associated into Group 1 are sent the Dim command. If this parameter is set to "Yes" the devices in Group 1 will not go to the same level as the ZDM230. + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Units in Group 4 only track when the dimmer is being turned ON and OFF and not while dimming. + + + + + The ZDM230 can operate shade control devices via its group 2. + + + + + The ZDM230 can operate shade control devices via its group 3. + + + + + The ZDM230 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting. + + + + + + Poll Group 2 Interval + + + Poll Group 2 + + + + + + + + + + + + + + diff --git a/openzwave/act/zdp100.xml b/openzwave/act/zdp100.xml new file mode 100644 index 00000000..4a362e7a --- /dev/null +++ b/openzwave/act/zdp100.xml @@ -0,0 +1,21 @@ + + + http://www.openzwave.com/device-database/0001:3030:4450 + images/act/zdp100.png + https://products.z-wavealliance.org/products/154/ + U.S. / Canada / Mexico + http://www.act-solutions.com/HomePro-Product-Matrix.html#Euro + Provides wireless dimming of lights 300 watt max Incandescent Only +- Includes a 3 prong pass through outlet. +- Lamp outlet is 2 prong. +- Supports load sensing. If the attached lamp is turned on manually, the module will detect the load change and turn itself on. This allows lamps to operated manually or through automation. +- Programmable ramp rates. Supports different ramp rates when controlled locally, or remotely. ON/OFF control of lights connected to the Plug-In Lamp Module. +- Plugs directly into wall outlet and provides a switched 120 VAC source. + ZDP100 - Scene Capable Dimmer Module + ZDP100 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/154/xml + + + + diff --git a/openzwave/act/zdw103.xml b/openzwave/act/zdw103.xml new file mode 100644 index 00000000..b12b6645 --- /dev/null +++ b/openzwave/act/zdw103.xml @@ -0,0 +1,69 @@ + + + + + + Dimmers controlled by this switch will start dimming from their current level. + + + + + In night-light mode the LED on the switch will turn ON when the switch is turned OFF. + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. + + + + + This dimmer will start dimming from its current level. + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + The ZDW103 can operate shade control devices via its group 2. + + + + + The ZDW103 can operate shade control devices via its group 3. + + + + + The ZDW103 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting. + + + + + + + + + + + + + + + diff --git a/openzwave/act/zdw232.xml b/openzwave/act/zdw232.xml new file mode 100644 index 00000000..e3f5775a --- /dev/null +++ b/openzwave/act/zdw232.xml @@ -0,0 +1,112 @@ + + + + + + +The ZDW232 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level embedded +in it. A dimmer receiving this command will start dimming from that start level. However, the command also has a +bit that indicates whether the dimmer should ignore the start level. If the bit is set to 1, the dimmer will ignore the +start level and instead start dimming from its current level. If this bit is set to 0, the dimmer will not ignore the start +level. + + + + + + You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without "un-associating" +those devices from the group. Setting parameter 2 to the value of 1 will stop the ZDW232 from transmitting to devices +that are "associated" into Group 4. +It is possible that you may only want the units in Group 4 to track when the dimmer is being turned ON and OFF +and not when dimming. + + + + + In night-light mode the LED on the switch will turn ON when the switch is turned OFF. + + + + + To change the top of the switch to OFF and the bottom of the switch to ON, set parameter 4 to 1. + + + + + The ZDW232 can be set to ignore the start level that is part of the dim command, regardless of whether the command +is telling the dimmer to ignore the start level or not ignore the start level embedded in the command (see Parameter +1). Setting parameter 5 to a value of 1 (factory default) will cause the ZDW232 to ignore the start level and to dim +or brighten from its current level. Setting the value to 0 will cause the ZDW232 to dim or brighten from the level in +the command. + + + + + When you press and hold the bottom of the ZDW232 switch once, the Z-Wave devices that are associated into Group +1 are sent the Dim command. If parameter 6 is set to 0, after you release the switch, the ZDW232 will command +devices in that group to go to the same level of the ZDW232. If parameter 6 is set to a value of 1 (factory default) +the devices in Group 1 will not go to the same level of the ZDW232. + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + After the ZDW232 is commanded to stop dimming, it will then command the Z-Wave devices in Group 4 to the +ZDW232's new level. To prevent the ZDW232 from commanding the Z-Wave devices in Group 4 during this particular +occurrence, set Parameter 13 to the value of 1. + + + + + The ZDW232 can operate shade control devices via its group 2 if this configuration parameter is set to 1. + + + + + The ZDW232 can operate shade control devices via its group 3 if this configuration parameter is set to 1. + + + + + The ZDW232 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting. + + + + + + Poll Group 2 Interval + + + Poll Group 2 + + + + + + + + + + + + + + + diff --git a/openzwave/act/zir010.xml b/openzwave/act/zir010.xml new file mode 100644 index 00000000..873666ee --- /dev/null +++ b/openzwave/act/zir010.xml @@ -0,0 +1,75 @@ + + + http://www.openzwave.com/device-database/0001:3330:4952 + images/act/zir010.png + https://products.z-wavealliance.org/products/549/ + U.S. / Canada / Mexico + http://www.act-solutions.com/HomePro-Product-Matrix.html#Euro + ZIR000 + PIR Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/549/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/550/xml + + https://products.z-wavealliance.org/products/550/ + U.S. / Canada / Mexico + + + + + + The ZIR010 can be configured to operate in 1 of 3 modes. + Those modes are: + Lighting Mode (factory default) + Alarm Mode + Sensor Mode + To change the mode of operation: + For Lighting Mode: Send a value of 0 to Configuration Parameter #17. + For Alarm Mode: Send a value of 1 to Configuration Parameter #17. + For Sensor Mode: Send a value of 2 to Configuration Parameter # 17. + + + + + + + + The configuration parameter that can be used to adjust the amount of delay before the OFF or IDLE command is transmitted is Configuration Parameter # 18. + This parameter can be configured with the value of 0 through 255. + Where 0 means no delay and 255 means 255 minutes of delay. + Default appears to be 1 min. + + + + + The ZIR010 can be disabled from sending commands unsolicited without removing associated devices by + setting Configuration Parameter # 19 to 0 (when asked for number of bytes, select 1). + Setting it back to 1 will re-enable the ZIR010. + + + + + + + The time the ZIR010 stays awake can be adjusted from 15 seconds to 45 seconds by sending a value of 15 + to 45 to the ZIR010 using Configuration Parameter # 22 (when asked for the number of bytes, select 1). + This awake time period starts over every time the ZIR010 receives a command or request. + Defaults to 30 seconds. + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/act/zrm230.xml b/openzwave/act/zrm230.xml new file mode 100644 index 00000000..ce2100dd --- /dev/null +++ b/openzwave/act/zrm230.xml @@ -0,0 +1,25 @@ + + + http://www.openzwave.com/device-database/0001:3330:524D + images/act/zrm230.png + https://products.z-wavealliance.org/products/476/ + The ZRM230 is a 6A, 230 VAC, 50 Hz, RF wall switch with 3-way capability. This wall switch can be controlled manually, with the ZTH200 +Z-Wave RF Remote Control, or the ACT multilevel auxiliary switch (AS200). This will control loads ON and OFF up to and inclduing 6A. + +The ZRM230 is a Dual Paddle design, where the first switch controls the connected load and also serves as a transmitter by using multiple switch taps (controls one group of 5 Z-Wave modules), and the second paddle is a transmitter only (controls two groups of 5 Z-Wave modules). + +Replaces the existing wall switch, and can add 3-way capability. + +Each ZRM230 Wall Mounted Switch functions as an automatic repeater to other HomePro Modules to ensure full home coverage of the RF signal. + +Has automatic Static Update Controller (SUC) capability + CEPT (Europe) + http://www.act-solutions.com/HomePro-Product-Matrix.html#Euro + ZRM230 - Wall Mounted 3-Way Switch 2-Gang + ZRM230 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/476/xml + + + + diff --git a/openzwave/act/zrp100.xml b/openzwave/act/zrp100.xml new file mode 100644 index 00000000..ba8020f7 --- /dev/null +++ b/openzwave/act/zrp100.xml @@ -0,0 +1,23 @@ + + + http://www.openzwave.com/device-database/0001:3030:5250 + images/act/zrp100.png + https://products.z-wavealliance.org/products/357/ + http://www.act-solutions.com/HomePro-Product-Matrix.html#Euro + ZRP100 (V3.30) + US Plug In Relay• Provides wireless ON/OFF control of lamps and other electrical appliances connected to the Plug-In Appliance Module. +• The wall hugging design plugs into a wall outlet and provides a grounded switched 120 VAC outlet on one side and a grounded pass thru "always powered" 120 VAC outlet on the other. Controlled outlet also has sense feature that turns it on when load is turned on. +• Each Plug-In Appliance Module functions as automatic repeater to other HomePro Modules to ensure full home coverage. +• Can request updates from a designated Static Update Controller (SUC). A Static Controller is one that is not moved after its addition to the network. The Static Controller can act as a gateway in the system, since other nodes always know its position. The “always listening” advantage of the Static Controller is that other nodes can transmit information frames to it whenever needed. + + ZRP100 + http://www.act-remote.com/HPW/Specs/ZRP100-S200_spec.pdf + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/152/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/194/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/357/xml + + + + diff --git a/openzwave/act/zrp110.xml b/openzwave/act/zrp110.xml new file mode 100644 index 00000000..66e0133f --- /dev/null +++ b/openzwave/act/zrp110.xml @@ -0,0 +1,7 @@ + + + + + + + diff --git a/openzwave/act/zrw103.xml b/openzwave/act/zrw103.xml new file mode 100644 index 00000000..0079f8c1 --- /dev/null +++ b/openzwave/act/zrw103.xml @@ -0,0 +1,57 @@ + + + http://www.openzwave.com/device-database/0001:3033:5257 + images/act/zrw103.png + https://products.z-wavealliance.org/products/413/ + US Wall Switch Relay 20A - 200 upt.Provides wireless RF ON/OFF (or manual) control of any light or lamp connected. +• Can control two groups of 5 modules each independent of its own state. +• Can replace current wall switch and can add 3-way or 4-way capability. +• Each ZRW103 Wall Mounted Switch functions as an automatic repeater to other Z-Wave Modules to ensure full home coverage of the RF signal. +• + Supports the Powerlevel command + + Has automatic Static Update Controller (SUC) capability. + This product supports 40Kbps data transmission. This product can also be used for networking support in systems that stream metadata. An example might include transmission of information from audio devices such as song album information to various displays around the home. + + U.S. / Canada / Mexico + http://www.act-solutions.com/HomePro-Product-Matrix.html#top + http://www.act-solutions.com/Contact-Advanced-Control-Technologies.html + ZRW103 + ZRW103 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/413/xml + + + + + + Dimmers controlled by this switch will start dimming from their current level. + + + + + In night-light mode the LED on the switch will turn ON when the switch is turned OFF. + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. + + + + + The ZRW103 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting. + + + + + + + + + + + + + + diff --git a/openzwave/act/zrw230.xml b/openzwave/act/zrw230.xml new file mode 100644 index 00000000..18044bbc --- /dev/null +++ b/openzwave/act/zrw230.xml @@ -0,0 +1,25 @@ + + + http://www.openzwave.com/device-database/0001:3330:5257 + images/act/zrw230.png + https://products.z-wavealliance.org/products/475/ + http://www.act-solutions.com/HomePro-Product-Matrix.html#Euro + CEPT (Europe) + ZRW230 - European Wall Mounted 1-Gang + The ZRW230 is a 6A, 230 VAC, 50 Hz, RF wall switch with 3-way capability. + +This wall switch can be controlled manually, with the ZTH200 RF Remote Control, or the ACT multilevel auxiliary switch (AS200). These will turn loads ON and OFF up to and including 6A. +The ON/OFF status will also be indicated by the state of its LED. The ZRW230 is a single paddle design which controls the connected load and serves as a transmitter using multiple button taps. + +Replaces the current wall switch, and can add 3-way capability. + +Each ZRW230 Wall Mounted Switch functions as an automatic repeater to other HomePro Modules to ensure full home coverage of the RF signal. + +Has automatic Static Update Controller (SUC) capability. + ZRW230 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/475/xml + + + + diff --git a/openzwave/aeotec/dsa03202.xml b/openzwave/aeotec/dsa03202.xml new file mode 100644 index 00000000..05524833 --- /dev/null +++ b/openzwave/aeotec/dsa03202.xml @@ -0,0 +1,105 @@ + + + http://www.openzwave.com/device-database/0086:0003:0001 + images/aeotec/dsa03202.png + https://products.z-wavealliance.org/products/143/ + Minimote Z-wave Remote Controller.The Aeon Labs Minimote is low-cost remote controller focused on end-user ease of use. + +Although simplicity and user experience is the primary focus, the full range of Z-Wave remote controller capabilities are left intact for the advanced user. Network installation is vastly improved via the interface. The Minimote is upgradeable by the end-user such that the latest Z-Wave protocols are always available. An internal lithium battery allows for months of usage and is recharged via USB. + CEPT (Europe) / U.S. / Canada / Mexico + Aeon Labs Minimote US + http://www.aeon-labs.com/site/products/view/3/ + DSA03xxx-ZWUS v1.13 + http://www.aeon-labs.com/site/support/ + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/142/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/143/xml + Added GetSupported false and add 3rd option to parameter 250 to work around this limitation + + + + + + + + + + false + + + Default Mode 0 The button on the Minimote uses the factory default functions for operation instead of any special functionality related to the below modes. Scene Mode 1 The button on the Minimote executes a scene from data received for Parameters Numbers 0-239 related to the button being pressed. Add Mode 2 The button on the Minimote is able to include/add devices into the Z-Wave network. Remove Mode 3 The button on the Minimote is able to remove devices from the Z-Wave network. Association Mode 4 The button on the Minimote is able to associate one device to another. Learn Mode 5 The button on the Minimote is able to allow the Minimote to be included into other Z-Wave networks and to learn Z-Wave network information. + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Enable selective Group Mode or Scene Mode. Long press learn button to wake up device. + Option As-Last-Set is not a real option, it exists because the Minimote does not report back its actual setting. + When long-pressing a button, if RED + BLUE LED turn on/off at the same time, device is in scene mode. + If the BLUE LED starts blinking, it is in group mode. + NOTE: Minimote firmware 1.17 or higher is required, firmware 1.19 is highly recommended. + + + + + + + + + + + false + + + + + + false + + + + + + + + + + + + false + + + diff --git a/openzwave/aeotec/dsa22.xml b/openzwave/aeotec/dsa22.xml new file mode 100644 index 00000000..6b1fceaf --- /dev/null +++ b/openzwave/aeotec/dsa22.xml @@ -0,0 +1,69 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Enable selective Group Mode or Scene Mode + + + + + Reset configuration set up to default setting + + + + + + + + + + diff --git a/openzwave/aeotec/dsa38.xml b/openzwave/aeotec/dsa38.xml new file mode 100644 index 00000000..5b04b0e2 --- /dev/null +++ b/openzwave/aeotec/dsa38.xml @@ -0,0 +1,42 @@ + + + http://www.openzwave.com/device-database/0086:0026:0001 + images/aeotec/dsa38.png + https://products.z-wavealliance.org/products/1288/ + DSA38-ZWAU + Aeon Labs Panic Button DSA38 ZWAU + Panic Button + CEPT (Europe) / U.S. / Canada / Mexico / Australia / New Zealand + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1284/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1285/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1288/xml + + + + + + + + + + Enable selective Group Mode or Scene Mode when the Panic Button is in Use mode + + + + + Reset configuration set up to default setting + + + + + + + + + diff --git a/openzwave/aeotec/dsb04100.xml b/openzwave/aeotec/dsb04100.xml new file mode 100644 index 00000000..6aa7b667 --- /dev/null +++ b/openzwave/aeotec/dsb04100.xml @@ -0,0 +1,62 @@ + + + http://www.openzwave.com/device-database/0086:0004:0002 + images/aeotec/dsb04100.png + https://products.z-wavealliance.org/products/114/ + The Aeon Labs Door/Window Sensor is a battery-powered Z-Wave magnetic door/window sensor with an extremely small form factor. The D/W sensor will send radio signals up to 6 associated Z-Wave devices within its own Z-Wave network when the main unit separates from the smaller unit. + +Bidirectional mounting plate and push button allows for easy end-user installation. The Aeon Labs Door/Window Sensor also has tamper prevention capabilities and low-battery alerts. + U.S. / Canada / Mexico + http://www.aeon-labs.com/site/support/ + DSB04100-ZWUS + Aeon Labs Door/Window Sensor + http://www.aeon-labs.com/site/products/view/1/ + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/114/xml + + + + + + + Default setting: Open: FF, Close: 00 + + + + + Default setting: Disable + + + + + Default setting: Open: FF, Close: 00 + + + + + Which reports need to send automatically in timing intervals for group 1. Bitsets: 0->Battery report, 4->Sensor Binary, 8->Basic Set, Default setting: 0x00000100 (Basic Set) + Ideal Setting for OZW is 17 (Sensor Binary and Battery Report) + + + Device Tag + + + Reset to factory defaults. + + + + + + true + + + + + + + + + diff --git a/openzwave/aeotec/dsb05.xml b/openzwave/aeotec/dsb05.xml new file mode 100644 index 00000000..d0fcb24a --- /dev/null +++ b/openzwave/aeotec/dsb05.xml @@ -0,0 +1,83 @@ + + + http://www.openzwave.com/device-database/0086:0005:0002 + images/aeotec/dsb05.png + https://products.z-wavealliance.org/products/771/ + DSB05-ZWAU + Multisensor + Never before has one device made a single corner of your room so smart. Never before has it done it inside. Never before has it done it outside. And never before has it brought all that intelligence to your Z-Wave network. + +The Aeotec by Aeon Labs MultiSensor looks like a motion sensor and acts like one too. But it’s also so much more. Placing this one piece of Z-Wave technology either in the corner of a room or outside is the same as placing 4 pieces of Z-Wave technology. But those 4 pieces of technology, those 4 pieces of intelligence that you can bring to your Z-Wave network, all live within a single, stunning sensor. + http://aeotec.com/z-wave-sensor + U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/710/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/763/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/771/xml + + + + + + + Stay awake for 10 minutes after batteries are inserted + + + + + How long should the device associated to multi sensor keep state On before sending it Off command (if the value is bigger than 255, the value would be rounded to next integer in minutes) + + + Enable Motion Sensor + + + + + Which commands to send when PIR motion sensor triggered + + + + + Reset to default parameters number 101-103. Any value other then 0 will initiate this reset. + + + Which reports need to send automatically in timing intervals for group 1. Bitsets: 0 -> Battery report, 5 -> Temperature, 6 -> Humidity, 7 -> Luminosity + + + Which reports need to send automatically in timing intervals for group 2. Bitsets: 0 -> Battery report, 5 -> Temperature, 6 -> Humidity, 7 -> Luminosity + + + Which reports need to send automatically in timing intervals for group 3. Bitsets: 0 -> Battery report, 5 -> Temperature, 6 -> Humidity, 7 -> Luminosity + + + Reset to default parameters number 111-113. Any value other then 0 will initiate this reset. + + + The interval of sending report group 1. 1 to 2678400 seconds + + + The interval of sending report group 2. 1 to 2678400 seconds + + + The interval of sending report group 3. 1 to 2678400 seconds + + + Reset to factory defaults. + + + + + + true + + + + + + + + + diff --git a/openzwave/aeotec/dsb09104.xml b/openzwave/aeotec/dsb09104.xml new file mode 100644 index 00000000..0e5d5114 --- /dev/null +++ b/openzwave/aeotec/dsb09104.xml @@ -0,0 +1,207 @@ + + + http://www.openzwave.com/device-database/0086:0009:0002 + images/aeotec/dsb09104.png + https://products.z-wavealliance.org/products/141/ + http://www.aeon-labs.com/site/products/category/1/ + http://www.aeon-labs.com/site/support/ + The Aeon Labs Smart Energy Monitor is a low-cost energy monitor for the entire home. It can wirelessly report immediate wattage and kWh usage to central control point gateways such as the 4HomeMedia CP and can be easily and safely installed by anyone. + + U.S. / Canada / Mexico / CEPT (Europe) + Aeon Labs Home Energy Meter EU + DSB09xxx-ZWUS v1.54 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/140/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/141/xml + + + + + + + + Voltage to calculate wattage from amperage. US=120. EU,ANZ=240. + + + + + Automatic report only when power is changed. + + + + + Threshold change in wattage to induce a automatic report (whole HEM). + + + + + Threshold change in wattage to induce a automatic report (Clamp 1). + + + + + Threshold change in wattage to induce a automatic report (Clamp 2). + + + + + Threshold change in wattage to induce a automatic report (Clamp 3). + + + + + Percentage change in wattage to induce a automatic report (whole HEM). + + + + + Percentage change in wattage to induce a automatic report (Clamp 1). + + + + + Percentage change in wattage to induce a automatic report (Clamp 2). + + + + + Percentage change in wattage to induce a automatic report (Clamp 3). + + + + + Accumulate energy when Battery Powered. + + + + + This byte denotes whether the product is using batteries (value = 0) or using USB power (value = 1). + + + + + Reset to default parameters number 101-103. Any value other then 0 will initiate this reset. + + + + + Which reports need to send in group1. Format is as follows: + Byte 1 (msb): Reserved + Byte 2: Reserved + Byte 3: Bit 7: reserved + Bit 6: reserved + Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1) + Byte 4 (lsb): Bit 7: reserved + Bit 6: reserved + Bit 5: reserved + Bit 4: reserved + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM) + Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM) + Bit 0: Auto Send Battery Report at the group time interval (whole HEM) + + + + + Which reports need to send in group2. Format is as follows: + Byte 1 (msb): Reserved + Byte 2: Reserved + Byte 3: Bit 7: reserved + Bit 6: reserved + Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1) + Byte 4 (lsb): Bit 7: reserved + Bit 6: reserved + Bit 5: reserved + Bit 4: reserved + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM) + Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM) + Bit 0: Auto Send Battery Report at the group time interval (whole HEM) + + + + + Which reports need to send in group3. Format is as follows: + Byte 1 (msb): Reserved + Byte 2: Reserved + Byte 3: Bit 7: reserved + Bit 6: reserved + Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1) + Byte 4 (lsb): Bit 7: reserved + Bit 6: reserved + Bit 5: reserved + Bit 4: reserved + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM) + Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM) + Bit 0: Auto Send Battery Report at the group time interval (whole HEM) + + + + + Reset to default parameters number 111-113. Any value other then 0 will initiate this reset. + + + + + The interval of sending report group 1. + + + + + The interval of sending report group 2. + + + + + The interval of sending report group 3. + + + + + Re-calibrate (will destroy factory calibration). CONTACT AEON LABS before using. + + + + + Device tag. + + + + + Reset to the default configuration. + + + + + + + false + + + + + + + + + diff --git a/openzwave/aeotec/dsb28-zweu.xml b/openzwave/aeotec/dsb28-zweu.xml new file mode 100644 index 00000000..0f9b337b --- /dev/null +++ b/openzwave/aeotec/dsb28-zweu.xml @@ -0,0 +1,17 @@ + + + http://www.openzwave.com/device-database/0086:0001:0002 + images/aeotec/dsb28-zweu.png + https://products.z-wavealliance.org/products/1322/ + http://aeotec.com/z-wave-home-energy-measure + CEPT (Europe) / Australia / New Zealand / Israel + Door/Window Sensor (2nd Edition) + DSB29-ZWIL + Aeon Labs Door/Window Sensor(2nd Edition) DSB29-ZWIL + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/805/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/806/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1322/xml + + + diff --git a/openzwave/aeotec/dsb28.xml b/openzwave/aeotec/dsb28.xml new file mode 100644 index 00000000..2d5103a7 --- /dev/null +++ b/openzwave/aeotec/dsb28.xml @@ -0,0 +1,192 @@ + + + http://www.openzwave.com/device-database/0086:001C:0002 + images/aeotec/dsb28.png + https://products.z-wavealliance.org/products/705/ + DSB28-ZWUS + U.S. / Canada / Mexico + You hear a lot about energy use these days. About how if we reduce the amount of energy we use we can not only save money but also save the environment. But saving money by using less electricity is only possible if we understand when and how we use it. That’s what Aeotec’s Z-Wave Home Energy Meter provides you with – understanding. + +Installed in an electricity box, the energy meter will monitor the total consumption of electricity used by an entire building. And its intelligent clamps will report that energy use back to your Z-Wave gateway or controller, in watts or kilowatt-hours, and in real time. So you can see how much electricity you really use and when you use it. + Home Energy Meter G2 + http://aeotec.com/z-wave-home-energy-measure + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/705/xml + + + + + + + + If the reverse clamping pliers, negative power is detected. + + + + + + + Automatic report only when power is changed. + + + + + + + Threshold change in wattage to induce a automatic report (whole HEM). + + + + + Threshold change in wattage to induce a automatic report (Clamp 1). + + + + + Threshold change in wattage to induce a automatic report (Clamp 2). + + + + + Threshold change in wattage to induce a automatic report (Clamp 3). + + + + + Percentage change in wattage to induce a automatic report (whole HEM). + + + + + Percentage change in wattage to induce a automatic report (Clamp 1). + + + + + Percentage change in wattage to induce a automatic report (Clamp 2). + + + + + Percentage change in wattage to induce a automatic report (Clamp 3). + + + + + Reset to default parameters number 101-103. Any value other then 0 will initiate this reset. + + + + + Which reports need to send in group1. Format is as follows: + Byte 1 (msb): Reserved + Byte 2: Reserved + Byte 3: Bit 7: reserved + Bit 6: reserved + Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1) + Byte 4 (lsb): Bit 7: reserved + Bit 6: reserved + Bit 5: reserved + Bit 4: reserved + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM) + Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM) + Bit 0: Auto Send Battery Report at the group time interval (whole HEM) + + + + + Which reports need to send in group2. Format is as follows: + Byte 1 (msb): Reserved + Byte 2: Reserved + Byte 3: Bit 7: reserved + Bit 6: reserved + Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1) + Byte 4 (lsb): Bit 7: reserved + Bit 6: reserved + Bit 5: reserved + Bit 4: reserved + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM) + Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM) + Bit 0: Auto Send Battery Report at the group time interval (whole HEM) + + + + + Which reports need to send in group3. Format is as follows: + Byte 1 (msb): Reserved + Byte 2: Reserved + Byte 3: Bit 7: reserved + Bit 6: reserved + Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1) + Byte 4 (lsb): Bit 7: reserved + Bit 6: reserved + Bit 5: reserved + Bit 4: reserved + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM) + Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM) + Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM) + Bit 0: Auto Send Battery Report at the group time interval (whole HEM) + + + + + Reset to default parameters number 111-113. Any value other then 0 will initiate this reset. + + + + + The interval of sending report group 1. + + + + + The interval of sending report group 2. + + + + + The interval of sending report group 3. + + + + + + + + + Device tag. + + + + + Reset to the default configuration. + + + + + + + + + + diff --git a/openzwave/aeotec/dsb29.xml b/openzwave/aeotec/dsb29.xml new file mode 100644 index 00000000..01823e20 --- /dev/null +++ b/openzwave/aeotec/dsb29.xml @@ -0,0 +1,67 @@ + + + http://www.openzwave.com/device-database/0086:001D:0002 + images/aeotec/dsb29.png + https://products.z-wavealliance.org/products/772/ + U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand + http://aeotec.com/z-wave-door-window-sensor + Door Window Sensor G2 + DSB29-ZWAU + We always think of tools in our house as ‘doing things’. Switches turn lights on. Remotes turn TVs off. Things do the basic stuff we tell them to – nothing more, nothing less. +That’s a description of a house of the past. + +The house of today has intelligence built in. Or at least it should. + +Inspired by the humble thermostat, Aeotec’s Z-Wave Door & Window Sensor sits as a part of our Intelligence range. Like a thermostat, we’ve designed it to find things out, to understand things about your home, and to then use that information to make your home more comfortable, to make your life easier. + +The Door & Window Sensor finds out something very simple – whether a door or a window, or in fact any object in your home, is open or closed. But there’s power in simplicity. Power that allows you to inform the rest of your Z-Wave network about your selected doors and windows. Like a thermostat lets your heating and cooling systems know what they should do next, Aeotec’s Z-Wave Door & Window Sensor does the same. Perhaps an open door means that your lights should turn on and welcome you home. Perhaps an open window means that an alarm should be trigged. Whatever it means to your home, with door and window sensors installed, your Z-Wave network will have both the power and the itelligence to do it. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/701/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/764/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/772/xml + + + + + + Default setting: Open: FF, Close: 00 + + + + + Default setting: Disable + + + + + Default setting: Open: FF, Close: 00 + + + + + Which reports need to send automatically in timing intervals for group 1. Bitsets: 0->Battery report, 4->Sensor Binary, 8->Basic Set, Default setting: 0x00000100 (Basic Set) + Ideal Setting for OZW is 17 (Sensor Binary and Battery Report) + + + Device Tag + + + Reset to factory defaults. + + + + + + true + + + + + + + + + diff --git a/openzwave/aeotec/dsb45.xml b/openzwave/aeotec/dsb45.xml new file mode 100644 index 00000000..ab898dd0 --- /dev/null +++ b/openzwave/aeotec/dsb45.xml @@ -0,0 +1,50 @@ + + + + + + Toggle the sensor binary report value when the Water Sensor is Triggered + + + + + Enable wake up 10 minutes when the power is switched on. + + + + + Toggle the basic set value when the Water Sensor is Triggered + + + + + To set which command will be sent to the associated nodes when the Water Sensor is triggered. + Bitsets: + 1 -> Battery + 4 -> Sensor Binary + 8 -> Basic Set + 12 -> Alarm + Default setting: 0x100 (Basic Set) + OZW Ideal Setting: 0x1011 (Battery, Sensor Binary Report, Alarm) + + + + Reset to factory defaults. + + + + + + false + + + + + + + + + diff --git a/openzwave/aeotec/dsb54.xml b/openzwave/aeotec/dsb54.xml new file mode 100644 index 00000000..615af8a0 --- /dev/null +++ b/openzwave/aeotec/dsb54.xml @@ -0,0 +1,62 @@ + + + + + + 0, Open: FF, Close: 00; 1, Open: 00, Close: FF; + Default setting: 0 + + + + 0, Open: FF, Close: 00; 1, Open: 00, Close: FF; + Default setting: 0 + + + + 0, Disable, 1, Enable; + Default setting: 0 + + + + This parameter is available when the low battery checking + function is activated or the device was waked up by other + actions (i.e. the z-wave button trigger, magnet switch + trigger and the Wake Up Interval Set timeout trigger). + The Recessed Door Sensor will check the battery power + when it was wake up as other ways. For example: the + z-wave button trigger, magnet switch trigger and the + Wake Up Interval Set timeout trigger. + Default setting: 86640 + + + + Bitsets: + 4 -> Sensor Binary + 8 -> Basic Set + Default setting: 0x00000100 (Basic Set) + + + + Device Tag + + + Reset to factory defaults. + + + + + + true + + + + + + + + + + diff --git a/openzwave/aeotec/dsc06106.xml b/openzwave/aeotec/dsc06106.xml new file mode 100644 index 00000000..7a428e26 --- /dev/null +++ b/openzwave/aeotec/dsc06106.xml @@ -0,0 +1,167 @@ + + + http://www.openzwave.com/device-database/0086:0006:0003 + images/aeotec/dsc06106.png + https://products.z-wavealliance.org/products/133/ + U.S. / Canada / Mexico + Smart Energy SwitchThe Aeon Labs Smart Energy Switch is a low-cost Z-Wave appliance switch which can report immediate wattage energy usage or kWh energy usage over a period of time. It can also be controlled by other Z-Wave devices to turn on/off to save electricity when appropriate. + +With an unobtrusive small form factor, the Aeon Labs Smart Energy Switch will not block other nearby Ac outlets. It is available in both matte white and matte black colors.. + http://www.aeon-labs.com/site/support/ + DSB06xxx-ZWUS + http://www.aeon-labs.com/site/products/view/5/ + Aeon Labs Smart Energy Switch + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/133/xml + + + + + + + Defines the contents of Multilevel Sensor Report after Multilevel Sensor Get received. + + + + + + + This is actually a double byte value. The LSB defines the total time the device needs to blink in seconds. The MSB defines the on/off interval of the blink in tenths of seconds. + + + + + Enables automatic notifications to associated devices whenever there is a state change. + + + + + + + + Enable/disable Wattage threshold and percent. + + + + + The minimum change in wattage for a report to be sent. + + + + + Minimum change in percent of wattage to send a report. + + + + + Set report types for groups 1, 2 and 3 to default. Reverts to 0 + after set. + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + + + Defines the time interval when the defined report for group 1 is sent. + + + + + Defines the time interval when the defined report for group 2 is sent. + + + + + Defines the time interval when the defined report for group 3 is sent. + + + + + Device tag. + + + + + Reset to the default configuration. + + + + + + + + + + diff --git a/openzwave/aeotec/dsc08101.xml b/openzwave/aeotec/dsc08101.xml new file mode 100644 index 00000000..fcae8420 --- /dev/null +++ b/openzwave/aeotec/dsc08101.xml @@ -0,0 +1,118 @@ + + + + + + + The content of "Multilevel Sensor Report Command" after SEI receives "Multilevel Sensor Get Command". + + + + + + Configuration Value 1 is to Specify the time that SEI need blink (0-255), the unit is second; + Configuration Value 2 is to Specify the Cycle of on/off (0-255), the unit of it is 0.1 second. + + + Set report types for groups 1, 2 and 3 to default. + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4(lsb) + bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 lsb) + bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) + bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + Defines the time interval when the defined report for group 1 is sent. + + + Defines the time interval when the defined report for group 2 is sent. + + + Defines the time interval when the defined report for group 3 is sent. + + + Device tag. + + + Reset to the default configuration. + + + + + + + + + + + diff --git a/openzwave/aeotec/dsc10.xml b/openzwave/aeotec/dsc10.xml new file mode 100644 index 00000000..cae8aa24 --- /dev/null +++ b/openzwave/aeotec/dsc10.xml @@ -0,0 +1,174 @@ + + + http://www.openzwave.com/device-database/0086:000A:0003 + images/aeotec/dsc10.png + https://products.z-wavealliance.org/products/704/ + Heavy-Duty Smart Energy Switch + U.S. / Canada / Mexico + http://aeotec.com/z-wave-plug-in-switch/1014-high-power-z-wave-switch.html + DSC10-ZWUS + Control, automate and record the electricity consumption of a premise’s heavy-duty appliances. Works in and outdoors with appliances up to 30 amps. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/704/xml + + + + + + + + + Current Overload Protection. Load will be closed when + the Current more than 39.5A and the time more than 5 + seconds + + + + + + LED status after power on + + + + + + + Enables automatic notifications to associated devices whenever there is a state change. + + + + + + + + Enable/disable Wattage threshold and percent. + + + + + The minimum change in wattage for a report to be sent. + + + + + Minimum change in percent of wattage to send a report. + + + + + Set report types for groups 1, 2 and 3 to default. Reverts to 0 + after set. + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC (KWH) + bit 2 MRC (watt) + bit 1 MSRC (Current) + bit 0 MRC (Voltage) + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC (KWH) + bit 2 MRC (watt) + bit 1 MSRC (Current) + bit 0 MRC (Voltage) + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC (KWH) + bit 2 MRC (watt) + bit 1 MSRC (Current) + bit 0 MRC (Voltage) + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + + + Defines the time interval when the defined report for group 1 is sent. + + + + + Defines the time interval when the defined report for group 2 is sent. + + + + + Defines the time interval when the defined report for group 3 is sent. + + + + + + + + Lock/ unlock all configuration parameters + + + + + Reset to factory defaults + + + + + + + + + + + + + diff --git a/openzwave/aeotec/dsc11.xml b/openzwave/aeotec/dsc11.xml new file mode 100644 index 00000000..045570ab --- /dev/null +++ b/openzwave/aeotec/dsc11.xml @@ -0,0 +1,197 @@ + + + http://www.openzwave.com/device-database/0086:000B:0003 + images/aeotec/dsc11.png + https://products.z-wavealliance.org/products/1015/ + Aeon Labs Smart Strip DSC11-ZWUS + U.S. / Canada / Mexico + DSC11-ZWUS + Smart Strip + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1015/xml + + + + + + + Enable selective reporting only when power change reaches a certain threshold or percentage set in 4.11 below. + This is used to reduce network traffic. + + + + + Threshold change in wattage to induce an automatic report (Whole Smart Strip). + + + Threshold change in wattage to induce an automatic report (Socket 1). + + + Threshold change in wattage to induce an automatic report (Socket 2). + + + Threshold change in wattage to induce an automatic report (Socket 3). + + + Threshold change in wattage to induce an automatic report (Socket 4). + + + Threshold change in wattage to induce an automatic report (Socket 5). + + + Threshold change in wattage to induce an automatic report (Socket 6). + + + Percentage change in wattage to induce an automatic report (Whole Smart Strip). + + + Percentage change in wattage to induce an automatic report (Socket 1). + + + Percentage change in wattage to induce an automatic report (Socket 2). + + + Percentage change in wattage to induce an automatic report (Socket 3). + + + Percentage change in wattage to induce an automatic report (Socket 4). + + + Percentage change in wattage to induce an automatic report (Socket 5). + + + Percentage change in wattage to induce an automatic report (Socket 6). + + + Defines the automated status notification of an associated device when status changes + + + + + + Get temperature of Smart Strip + + + + Set report types for groups 1, 2 and 3 to default. + + + + Configure auto report which information as Group 1. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 + bit 7 reserved + bit 6 Auto report power level with specified time interval (channel 6) + bit 5 Auto report power level with specified time interval (channel 5) + bit 4 Auto report power level with specified time interval (channel 4) + bit 3 Auto report power level with specified time interval (channel 3) + bit 2 Auto report power level with specified time interval (channel 2) + bit 1 Auto report power level with specified time interval (channel 1) + bit 0 Auto report the total power level with specified time interval + Value 4 (lsb) + bit 7 reserved + bit 6 Auto report power consumption with specified time interval (channel 6) + bit 5 Auto report power consumption with specified time interval (channel 5) + bit 4 Auto report power consumption with specified time interval (channel 4) + bit 3 Auto report power consumption with specified time interval (channel 3) + bit 2 Auto report power consumption with specified time interval (channel 2) + bit 1 Auto report power consumption with specified time interval (channel 1) + bit 0 Auto report the total power consumption with specified time interval + + + + Configure auto report which information as Group 2. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 + bit 7 reserved + bit 6 Auto report power level with specified time interval (channel 6) + bit 5 Auto report power level with specified time interval (channel 5) + bit 4 Auto report power level with specified time interval (channel 4) + bit 3 Auto report power level with specified time interval (channel 3) + bit 2 Auto report power level with specified time interval (channel 2) + bit 1 Auto report power level with specified time interval (channel 1) + bit 0 Auto report the total power level with specified time interval + Value 4 (lsb) + bit 7 reserved + bit 6 Auto report power consumption with specified time interval (channel 6) + bit 5 Auto report power consumption with specified time interval (channel 5) + bit 4 Auto report power consumption with specified time interval (channel 4) + bit 3 Auto report power consumption with specified time interval (channel 3) + bit 2 Auto report power consumption with specified time interval (channel 2) + bit 1 Auto report power consumption with specified time interval (channel 1) + bit 0 Auto report the total power consumption with specified time interval + + + + Configure auto report which information as Group 3. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 + bit 7 reserved + bit 6 Auto report power level with specified time interval (channel 6) + bit 5 Auto report power level with specified time interval (channel 5) + bit 4 Auto report power level with specified time interval (channel 4) + bit 3 Auto report power level with specified time interval (channel 3) + bit 2 Auto report power level with specified time interval (channel 2) + bit 1 Auto report power level with specified time interval (channel 1) + bit 0 Auto report the total power level with specified time interval + Value 4 (lsb) + bit 7 reserved + bit 6 Auto report power consumption with specified time interval (channel 6) + bit 5 Auto report power consumption with specified time interval (channel 5) + bit 4 Auto report power consumption with specified time interval (channel 4) + bit 3 Auto report power consumption with specified time interval (channel 3) + bit 2 Auto report power consumption with specified time interval (channel 2) + bit 1 Auto report power consumption with specified time interval (channel 1) + bit 0 Auto report the total power consumption with specified time interval + + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + + + Defines the time interval when the defined report for group 1 is sent. + + + + + Defines the time interval when the defined report for group 2 is sent. + + + + + Defines the time interval when the defined report for group 3 is sent. + + + + Enable/disable Configuration Locked + + + + + Enter Meter Calibration Mode + + + + Device tag. + + + + Reset to the default configuration. + + + + + + + + + diff --git a/openzwave/aeotec/dsc12104.xml b/openzwave/aeotec/dsc12104.xml new file mode 100644 index 00000000..dd4c6341 --- /dev/null +++ b/openzwave/aeotec/dsc12104.xml @@ -0,0 +1,153 @@ + + + + + + + + This is actually a double byte value. The LSB defines the total time the device needs to blink in seconds. The MSB defines the on/off interval of the blink in tenths of seconds. + + + + Current Overload Protection + + + + + + Enables automatic notifications to associated devices whenever there is a state change. + + + + + + + + Enable/disable Wattage threshold and percent. + + + + + The minimum change in wattage for a report to be sent. + + + + + Minimum change in percent of wattage to send a report. + + + + + Set report types for groups 1, 2 and 3 to default. Reverts to 0 + after set. + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + + + Defines the time interval when the defined report for group 1 is sent. + + + + + Defines the time interval when the defined report for group 2 is sent. + + + + + Defines the time interval when the defined report for group 3 is sent. + + + + Set External Switch/Button Control mode + + + + + Device tag. + + + Reset to the default configuration. + + + + + + + + + + diff --git a/openzwave/aeotec/dsc13104.xml b/openzwave/aeotec/dsc13104.xml new file mode 100644 index 00000000..26b8da67 --- /dev/null +++ b/openzwave/aeotec/dsc13104.xml @@ -0,0 +1,138 @@ + + + + + + + + Configuration Value 1 is to Specify the time that SEI need blink (0-255), the unit is second; + Configuration Value 2 is to Specify the Cycle of on/off (0-255), the unit of it is 0.1 second. + + + Load will be closed when the Current overruns (EU 16.2A) for more than 2 minutes + + + + + Defines the automated status notification of an associated device when status changes + + + + + + Enable/disable Wattage threshold and percent. + + + The value represents the minimum change in wattage for a Report to be sent (default 25 W) + + + The value represents the minimum percentage change in wattage for a Report to be sent (Default 5) + + + Set report types for groups 1, 2 and 3 to default. + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4(lsb) + bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 lsb) + bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) + bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + Defines the time interval when the defined report for group 1 is sent. + + + Defines the time interval when the defined report for group 2 is sent. + + + Defines the time interval when the defined report for group 3 is sent. + + + Set External Switch/Button Control mode + + + + + Device tag. + + + Reset to the default configuration. + + + + + + + + + + + diff --git a/openzwave/aeotec/dsc14104.xml b/openzwave/aeotec/dsc14104.xml new file mode 100644 index 00000000..4389eb1d --- /dev/null +++ b/openzwave/aeotec/dsc14104.xml @@ -0,0 +1,73 @@ + + + http://www.openzwave.com/device-database/0086:000E:0003 + images/aeotec/dsc14104.png + https://products.z-wavealliance.org/products/1623/ + DSC14104-ZWUS + Micro Motor Controller + Aeon Labs Micro Motor Controller DSC14104 ZWUS + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1623/xml + + + + + + + Motor start delay time (ms) + + + + Total time from endpoint of close go to endpoint of opening (ms). + This value set 0x00000000, will use the time of last calibration. + Default 5 seconds + + + + Total time from endpoint of opening go to endpoint of close (ms). + This value set 0x00000000, will use the time of last calibration. + Default 5 seconds + + + Motor status after power on + + + + + + + Set count of External Button/Switch + Note: Single External Button must connect to ST and COM port. + + + + + + Enable automatic notifications to associated group Reports devices whenever there is a state change + + + + + + Set External Switch/Button Control mode + + + + + Device tag. + + + Reset to the default configuration. + + + + + + + + + diff --git a/openzwave/aeotec/dsc18103.xml b/openzwave/aeotec/dsc18103.xml new file mode 100644 index 00000000..08701cbc --- /dev/null +++ b/openzwave/aeotec/dsc18103.xml @@ -0,0 +1,169 @@ + + + http://www.openzwave.com/device-database/0086:0012:0003 + images/aeotec/dsc18103.png + https://products.z-wavealliance.org/products/775/ + U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand + Micro Smart Energy Switch G2 + It has long been thought that a house becomes a home when we make it reflect who we are, when we personalise it, when we fill it with objects we treasure. And all of that remains true, but it no longer needs to be just the objects we put in our home that personalises it. Like the music that gently fills the background of your favourite restaurant, Aeotec’s Micro Switches create the perfect ambiance for your home, and then some. They also give you the perfect control and the perfect, intelligent automation. + +Across three different Micro controllers, each one letting you perfect everything from your home’s lights to its appliances and to its motorised doors and curtains, you’ll find that the same magic has been built right into the tiny body of each switch. + DSC18103-ZWAU + http://aeotec.com/z-wave-in-wall-switches + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/708/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/767/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/775/xml + + + + + + + + Defines the contents of Multilevel Sensor Report after Multilevel Sensor Get received. + + + + + + + This is actually a double byte value. The LSB defines the total time the device needs to blink in seconds. The MSB defines the on/off interval of the blink in tenths of seconds. + + + + + Enables automatic notifications to associated devices whenever there is a state change. + + + + + + + + Enable/disable Wattage threshold and percent. + + + + + The minimum change in wattage for a report to be sent. + + + + + Minimum change in percent of wattage to send a report. + + + + + Set report types for groups 1, 2 and 3 to default. Reverts to 0 + after set. + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + + + Defines the time interval when the defined report for group 1 is sent. + + + + + Defines the time interval when the defined report for group 2 is sent. + + + + + Defines the time interval when the defined report for group 3 is sent. + + + + + Device tag. + + + + + Reset to the default configuration. + + + + + + + + + + diff --git a/openzwave/aeotec/dsc19103.xml b/openzwave/aeotec/dsc19103.xml new file mode 100644 index 00000000..4718ddbd --- /dev/null +++ b/openzwave/aeotec/dsc19103.xml @@ -0,0 +1,192 @@ + + + http://www.openzwave.com/device-database/0086:0013:0003 + images/aeotec/dsc19103.png + https://products.z-wavealliance.org/products/774/ + Micro Smart Energy Illuminator G2 + U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand + With so many new-generation, energy-saving lights now available for your home, dimming lights isn’t as straightforward as it used to be. There’s no one type of light any more. Aeotec’s plug-in Smart Energy Illuminator is, however, compatible with as many dimmable lights as possible. + +Our Smart Energy Illuminator has been designed to work out of the box with halogen lamp, sodium and tungsten lights. It’s also capable of being plugged in to other types of lights that work by reducing the amount of electricity being passed to their transformer. This includes select LED lights. + DSC19103-ZWAU + http://aeotec.com/z-wave-in-wall-switches + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/707/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/766/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/774/xml + + + + + + + + This is actually a double byte value. The LSB defines the total time the device needs to blink in seconds. The MSB defines the on/off interval of the blink in tenths of seconds. + + + + + Current Overload Protection. Load will be closed when 3 + the Current more than 2.7A and the time more than 2 + minutes + + + + + + + + Enables automatic notifications to associated devices whenever there is a state change. + + + + + + + + Enable/disable Wattage threshold and percent. + + + + + The minimum change in wattage for a report to be sent. + + + + + Minimum change in percent of wattage to send a report. + + + + + Set report types for groups 1, 2 and 3 to default. Reverts to 0 + after set. + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC (KWH) + bit 2 MRC (watt) + bit 1 MSRC (Current) + bit 0 MRC (Voltage) + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC (KWH) + bit 2 MRC (watt) + bit 1 MSRC (Current) + bit 0 MRC (Voltage) + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC (KWH) + bit 2 MRC (watt) + bit 1 MSRC (Current) + bit 0 MRC (Voltage) + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + + + Defines the time interval when the defined report for group 1 is sent. + + + + + Defines the time interval when the defined report for group 2 is sent. + + + + + Defines the time interval when the defined report for group 3 is sent. + + + + Turn external button mode + + + + + + + + + Device tag. + + + + + Reset to the default configuration. + + + + + + + + + + + diff --git a/openzwave/aeotec/dsc24.xml b/openzwave/aeotec/dsc24.xml new file mode 100644 index 00000000..6f9477a9 --- /dev/null +++ b/openzwave/aeotec/dsc24.xml @@ -0,0 +1,181 @@ + + + http://www.openzwave.com/device-database/0086:0018:0003 + images/aeotec/dsc24.png + https://products.z-wavealliance.org/products/778/ + The Aeotec Smart Energy Switch is a low-cost Z-Wave appliance switch which can report immediate wattage energy usage or kWh energy usage over a period of time. It can also be controlled by other Z-Wave devices to turn on/off to save electricity when appropriate. + +With an unobtrusive small form factor, the Aeon Labs Smart Energy Switch will not block other nearby AC outlets. It is available in matte white. + DSC24-ZWAU + U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand + http://aeotec.com/z-wave-plug-in-switch + Smart Energy Switch G2 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/712/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/770/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/778/xml + + + + + + + + + Configuration Value 1: 1-255 + Configuration Value 1 is to Specify the time that Smart Switch need blink, The unit is Second; + Configuration Value 2: 1-255 + Configuration Value 2 is to Specify the Cycle of on/off, the unit of it is 0.1 second. + + + + Load will be closed when the Current overruns (EU 16.2A) for more than 2 minutes + + + + + Configure the output load status after re-power on. + + + + + + Defines the automated status notification of an associated device when status changes + + + + + + + Enable/disable Wattage threshold and percent. + + + + The value represents the minimum change in wattage for a Report to be sent (default 25 W) + + + The value represents the minimum percentage change in wattage for a Report to be sent (Default 5) + + + + Set report types for groups 1, 2 and 3 to default. + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 MRC(KWH) + bit 2 MRC(watt) + bit 1 MSRC + bit 0 reserved + + The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(KWh) automatically. + + The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) + Meter Report Command(wattage) automatically. + + The MSRC flag signals that Report Group 1 send(1) or don't send(0) + Multilevel Sensor Report Command(wattage) automatically. + + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + + + Defines the time interval when the defined report for group 1 is sent. + + + + + Defines the time interval when the defined report for group 2 is sent. + + + + + Defines the time interval when the defined report for group 3 is sent. + + + + Partner ID + + + + + Enable/disable Configuration Locked + + + + + + Device tag. + + + + + Reset to the default configuration. + + + + + + + + + + + diff --git a/openzwave/aeotec/dsc26103.xml b/openzwave/aeotec/dsc26103.xml new file mode 100644 index 00000000..671eccb6 --- /dev/null +++ b/openzwave/aeotec/dsc26103.xml @@ -0,0 +1,66 @@ + + + http://www.openzwave.com/device-database/0086:001A:0003 + images/aeotec/dsc26103.png + https://products.z-wavealliance.org/products/776/ + http://aeotec.com/z-wave-in-wall-switches + U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand + It has long been thought that a house becomes a home when we make it reflect who we are, when we personalise it, when we fill it with objects we treasure. And all of that remains true, but it no longer needs to be just the objects we put in our home that personalises it. Like the music that gently fills the background of your favourite restaurant, Aeotec’s Micro Switches create the perfect ambiance for your home, and then some. They also give you the perfect control and the perfect, intelligent automation. + +Across three different Micro controllers, each one letting you perfect everything from your home’s lights to its appliances and to its motorised doors and curtains, you’ll find that the same magic has been built right into the tiny body of each switch. + Micro Switch G2 + DSC26103-ZWAU + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/709/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/768/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/776/xml + + + + + + + This is actually a double byte value. The LSB defines the total time the device needs to blink in seconds. The MSB defines the on/off interval of the blink in tenths of seconds. + + + + Enables automatic notifications to associated devices whenever there is a state change. + + + + + + Turn external button mode + + + + + + + Partner ID + + + + + Enable/disable Configuration Locked + + + + + Device tag. + + + Reset to the default configuration. + + + + + + + + + + diff --git a/openzwave/aeotec/dsc27103.xml b/openzwave/aeotec/dsc27103.xml new file mode 100644 index 00000000..03f00be4 --- /dev/null +++ b/openzwave/aeotec/dsc27103.xml @@ -0,0 +1,70 @@ + + + http://www.openzwave.com/device-database/0086:001B:0003 + images/aeotec/dsc27103.png + https://products.z-wavealliance.org/products/773/ + http://aeotec.com/z-wave-in-wall-switches + Micro Illuminator G2 + DSC27103-ZWAU + It has long been thought that a house becomes a home when we make it reflect who we are, when we personalise it, when we fill it with objects we treasure. And all of that remains true, but it no longer needs to be just the objects we put in our home that personalises it. Like the music that gently fills the background of your favourite restaurant, Aeotec’s Micro Switches create the perfect ambiance for your home, and then some. They also give you the perfect control and the perfect, intelligent automation. + +Across three different Micro controllers, each one letting you perfect everything from your home’s lights to its appliances and to its motorised doors and curtains, you’ll find that the same magic has been built right into the tiny body of each switch. + U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/706/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/765/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/773/xml + + + + + + + Configuration Value 1 is to Specify the time that SEI need blink (0-255), the unit is second; + Configuration Value 2 is to Specify the Cycle of on/off (0-255), the unit of it is 0.1 second. + + + Enable/Disable CRC16 encapsulation + + + + + Defines the automated status notification of an associated device when status changes + + + + + + Turn external button mode + + + + + + + Partner ID + + + + + Enable/disable Configuration Locked + + + + + Device tag. + + + Reset to the default configuration. + + + + + + + + + diff --git a/openzwave/aeotec/dsc35103.xml b/openzwave/aeotec/dsc35103.xml new file mode 100644 index 00000000..8ef1ae81 --- /dev/null +++ b/openzwave/aeotec/dsc35103.xml @@ -0,0 +1,55 @@ + + + http://www.openzwave.com/device-database/0086:0011:0003 + images/aeotec/dsc35103.png + https://products.z-wavealliance.org/products/1622/ + Micro Double Smart Switch + Aeon Labs Micro Double Smart Switch DSC17103 ZWUS + U.S. / Canada / Mexico + DSC17103 ZWUS + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1622/xml + + + + + + + This is actually a double byte value. + The LSB defines the total time the device needs to blink in seconds. + The MSB defines the on/off interval of the blink in tenths of seconds. + + + + Enables automatic notifications to associated devices whenever there is a state change. + + + + + + Set External Switch/Button Control mode + + + + + + + Device tag. + + + + + Reset to the default configuration. + + + + + + + + + + diff --git a/openzwave/aeotec/dsd37.xml b/openzwave/aeotec/dsd37.xml new file mode 100644 index 00000000..7c068dbe --- /dev/null +++ b/openzwave/aeotec/dsd37.xml @@ -0,0 +1,40 @@ + + + http://www.openzwave.com/device-database/0086:0025:0004 + images/aeotec/dsd37.png + https://products.z-wavealliance.org/products/1017/ + DSD37-ZWAU + U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand + Aeon Labs Range Extender DSD37-ZWAU + Range Extender / Repeater + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/752/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1004/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1017/xml + + + + + + + Partner ID + + + + + Device Tag + + + Reset to factory defaults. + + + + + + + + + diff --git a/openzwave/aeotec/zw056.xml b/openzwave/aeotec/zw056.xml new file mode 100644 index 00000000..063d7147 --- /dev/null +++ b/openzwave/aeotec/zw056.xml @@ -0,0 +1,141 @@ + + + http://www.openzwave.com/device-database/0086:0038:0104 + images/aeotec/zw056.png + https://products.z-wavealliance.org/products/1307/ + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + N/A + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is missing or inoperable. + Doorbell Gen5 + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + Aeon Labs Doorbell supports playing MP3 music files with a press of this doorbell. It has a 128MB flash memory that can store up to 800 ringtones. The volume can be adjusted manually via short press on the Volume Button, also you can switch the doorbell sound to the next via long press on the Volume Button. You may change/update your doorbell ringtone at any point in time you want by connecting your Doorbell to your PC to update the sound track on your Doorbell’s flash memory. +There is a small Wireless Button, which can trigger the doorbell on the other side of the wall to play the selected doorbell music when pressed. +It also act as a repeater that forward Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node. +By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary “listening” Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. +Also a tool that can be programmed, scheduled, controlled and communicated with from anywhere in the world. + ZW056-A + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1583/Aeon Labs Doorbell Gen5 manual.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1307/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1581/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1583/xml + + https://products.z-wavealliance.org/products/1581/ + ZW056-B + Australia / New Zealand + https://products.z-wavealliance.org/products/1583/ + ZW056-C + CEPT (Europe) + + + + + + Set the repetitions for playing doorbell ringtone. + Value=1 to 255, the range of repetition is 1 to 100. + Note: If the time of playing doorbell ringtone is more than 20s, + the volume of ringtone will reduce to silence no matter how + many repetitions of doorbell ringtone are set. + + + + + Set the default doorbell ringtone. + Value=1-100, Specify the ringtone as default. + + + + + Select a ringtone to play. + Value=0, stop playing. + Value=1-100, play the specified ringtone. + Value=255, play the default ringtone. + Value=other, ignore. + + + + Playback Control + + + + + + + + Set the volume of ringtone + + + + Define functions of "Button -" and "Button+". + Button - is previous, Button+ is next. + + + + + + + Define functions of "Button -" and "Button+" when short + pressing and long pressing it. + + + + + + Get Wireless Button Battery Status + + + + + Defines the automated status notification of an associated device when status changes + + + + + + Defines the automated status notification of an associated device when the wireless button battery level changes + + + + + + Pair the Wireless Button with Doorbell. + Value=0x55555555, Start the Wireless Button pairing mode and + the blue Led will blink slowly, short press the Wireless Button + once, if the blue Led change to be solid, which means the pairing + is successful. Otherwise, repeat the steps. + It will automatically exit the pairing mode after 8s if there is no + pressing action of the Wireless Button. + Note: + You can send this configuration Get CC to ask the pairing result: + If configuration report value=0x00000000, which means the + pairing is failed. + If configuration report value =0xFFFFFFFF, which means the + pairing is successful. + + + + + + Enable/disable Configuration Locked + + + + + Reset to factory defaults + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw062.xml b/openzwave/aeotec/zw062.xml new file mode 100644 index 00000000..a794e5c9 --- /dev/null +++ b/openzwave/aeotec/zw062.xml @@ -0,0 +1,204 @@ + + + http://www.openzwave.com/device-database/0086:003E:0103 + images/aeotec/zw062.png + https://products.z-wavealliance.org/products/1445/ + Garage Door Controller Gen5 + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Z-Wave button that you can find on the product's housing. + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Z-Wave button that you can find on the product's housing. + Press and hold the Z-Wave button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is missing or inoperable. + Aeon Labs Garage Door Controller is a smart and wireless Garage Door Control system, you can control the garage door to open, close, or stop moving via wireless signal on your gateway client or phone application. +The Garage Door Controller allows you to configure different alarm sounds to indicate the door’s action. Each action alarm sound can be customized. To change or update new alarm sounds for the Garage Door Controller, connect the Garage Door Controller to your PC host with a USB cable and download your sound files to the flash memory (128 MB) of the Garage Door Controller. +It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. +It is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1497/Aeon Labs Garage Door Controller Gen5 manual.pdf + U.S. / Canada / Mexico + ZW062-A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1445/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1496/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1497/xml + + https://products.z-wavealliance.org/products/1496/ + ZW062-B + Australia / New Zealand + https://products.z-wavealliance.org/products/1497/ + ZW062-C + CEPT (Europe) + + + + + + false + + + + + + + Configure the default startup ringtone. + Value = 0, disable the Startup ringtone. + Value = Others, Enable and select a startup ringtone for the Garage Door Controller + + + + + Calibration Steps: + 1. Let the garage door move to full close position. + 2. Send this parameter (0x22) with value=1 to Garage Door Controller. + 3. Let the garage door move to full open position. + 4. Let the garage door move to full close position after the step 3 is completed. + After the step 4 is completed, all calibration steps are complete. + Note: This process should be implemented when the Garage Door Controller just only has one Sensor is installed on the garage door. + + + + + + Set the timeout of all calibration steps for the Sensor + + + + Get the numbers of alarm music. (not support Set CC) + + + + + 1, Value1: configure the frequency of blinking for the Alarm LEd, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10. + 2, Value2: configure the alarm sound (there are 4 types sound saved in EEPROM and user also can update it). + 3, Value3: configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels). + 4, Value4=0, disable the alarm prompt. Value4=1, enable the alarm prompt. + value is sum: + 16777216 x led_frequency + + 65536 x alarm_sound + + 256 x volume + + 1 x alarm_mode + + + + + 1, Value1: configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10. + 2, Value2: configure the alarm sound (there are 4 types sound saved in EEPROM and user also can update it). + 3, Value3: configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels). + 4, Value4=0, disable the alarm prompt. Value4=1, enable the alarm prompt. + value is sum: + 16777216 x led_frequency + + 65536 x alarm_sound + + 256 x volume + + 1 x alarm_mode + + + + + 1, Value1: configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10. + 2, Value2: configure the alarm sound (there are 4 types sound saved in EEPROM and user also can update it). + 3, Value3: configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels). + 4, Value4=0, disable the alarm prompt. Value4=1, enable the alarm prompt. + value is sum: + 16777216 x led_frequency + + 65536 x alarm_sound + + 256 x volume + + 1 x alarm_mode + + + + + 1, Value1: configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10. + 2, Value2: configure the alarm sound (there are 4 types sound saved in EEPROM and user also can update it). + 3, Value3: configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels). + 4, Value4=0, disable the alarm prompt. Value4=1, enable the alarm prompt. + value is sum: + 16777216 x led_frequency + + 65536 x alarm_sound + + 256 x volume + + 1 x alarm_mode + + + + + Note: + 1. The Garage Door Controller will send this configuration report to gateway controller or associated nodes automatically if the Sensor is removed. + 2. You can send the value=0x55555555 of this parameter to controller to relieve the alarm state. + + + + + + + It will report the battery power state to associated nodes automatically when the battery power is in low battery. + + + + + + Value=0xff, stop playing ringtone. + Value=1 to 100, start playing the ringtone that you selected. + + + + + Value=1 to value=10, which map to the volume level 1 to level 10 + + + + + The temperature value contains one decimal point. + E.g. If the report value=252(0x00FC), the temperature is 25.2. + Rang is 0 to 500 (0 to 50.0). + + + + + Value=0, short pressing the Button +/- will be used to adjust the volume of sound. Long pressing the Button +/- will be used to switch the sound to the next. + Value=1, short pressing the Button +/- will be used to switch the sound to the next. Long pressing the Button +/- will be used to adjust the volume of sound. + + + + + + It will send the Hail CC/configuration report CC when the state of garage door is changed + + + + + + + Value=0x55555501, which will trigger to start the pairing of Sensor (installed on the top of the garage door), at this time, the Network LED on the Garage Door Controller will blink slowly and then short press Temper Switch back of the Sensor. + If pairing is successful, the Network LED will stop blinking and the Garage Door Controller will send the configuration report with value=0x01FF to primary controller/gateway. Otherwise, repeat the operation. + Note: + 1. If you do not press the Temper Switch when starting the pairing mode, the pairing status will keep for 8 second and then exit the pairing status automatically. + 2. The Sensor has been paired with the Garage Door Controller after factory. + + + + + + Lock/ unlock all configuration parameters + + + + + Reset to factory defaults + + + + + + + + + true + + + + + + + + + + diff --git a/openzwave/aeotec/zw074.xml b/openzwave/aeotec/zw074.xml new file mode 100644 index 00000000..2829cdbe --- /dev/null +++ b/openzwave/aeotec/zw074.xml @@ -0,0 +1,127 @@ + + + http://www.openzwave.com/device-database/0086:004A:0102 + images/aeotec/zw074.png + https://products.z-wavealliance.org/products/1163/ + The Aeotec by Aeon Labs MultiSensor Gen5 looks like a motion sensor and it acts like one too. But it’s also so much more. Installing this 1 piece of Z-Wave technology is the same as installing 4 pieces of Z-Wave technology. Your home control network will immediately understand motion, temperature, humidity and light readings wherever Multisensor installed. Those intelligent readings will equate to intelligence automation. And intelligent automation will give you the perfect, smart home. + ZW074-A + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Z-Wave button that you can find in back of the product. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1170/Instructions - MultiSensor Gen5 MCert1.pdf + MultiSensor Gen5 + Press and hold the Z-Wave button that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Z-Wave button that you can find in the back of the product. + Press and hold the Z-Wave button for 3 seconds will trigger sending the Wake up notification command. If press the Z-Wave button 3 times, the MultiSensor will wake up for 10 minutes. + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1163/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1169/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1170/xml + + https://products.z-wavealliance.org/products/1169/ + ZW074-B + Australia / New Zealand + https://products.z-wavealliance.org/products/1170/ + ZW074-C + CEPT (Europe) + + + + + Stay awake for 10 minutes after batteries are inserted + + + + + How long should the device associated to multi sensor keep state On before sending it Off command (if the value is bigger than 255, the value would be rounded to next integer in minutes) + + + Enable Motion Sensor + + + + + Which commands to send when PIR motion sensor triggered + OZW Ideal Value is Binary Sensor Report + + + + + Enable/disable the selective reporting only when measurements reach a certain threshold or percentage + set in the threshold settings. This is used to reduce network + traffic. + + + + + Threshold change in temperature to induce an automatic report. + Note: + 1. When the unit is Celsius, threshold=Value. + 2. When the unit is Fahrenheit, threshold=Value*1.8. The accuracy is 0.1. + 3. The high byte is the part of integer, the low byte is the fractional part. + + + + Threshold change in humidity to induce an automatic report. + Note: + The accuracy is 0.1. + The high byte is the part of integer, the low byte is the fractional part. + + + + Threshold change in luminance to induce an automatic report. + + + Threshold change in battery level to induce an automatic report. + Note: + The accuracy is 0.1. + The high byte is the part of integer, the low byte is the fractional part. + + + + Enable/disable to send the alarm report of low temperature(Less than 15 Degress C) + + + + + + Which reports need to send automatically in timing intervals for group 1. Bitsets: 0 -> Battery report, 5 -> Temperature, 6 -> Humidity, 7 -> Luminosity + + + Which reports need to send automatically in timing intervals for group 2. Bitsets: 0 -> Battery report, 5 -> Temperature, 6 -> Humidity, 7 -> Luminosity + + + Which reports need to send automatically in timing intervals for group 3. Bitsets: 0 -> Battery report, 5 -> Temperature, 6 -> Humidity, 7 -> Luminosity + + + The interval of sending report group 1. 1 to 2678400 seconds + + + The interval of sending report group 2. 1 to 2678400 seconds + + + The interval of sending report group 3. 1 to 2678400 seconds + + + + Enable/disable Lock Configuration + + + + + + Reset to factory defaults. + + + + + + false + + + + + + + + + diff --git a/openzwave/aeotec/zw075.xml b/openzwave/aeotec/zw075.xml new file mode 100644 index 00000000..df897eb4 --- /dev/null +++ b/openzwave/aeotec/zw075.xml @@ -0,0 +1,163 @@ + + + http://www.openzwave.com/device-database/0086:004B:0003 + images/aeotec/zw075.png + https://products.z-wavealliance.org/products/1045/ + N/A + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + CEPT (Europe) + Smart Switch Gen5 + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + Aeon Labs Smart Switch Gen5 is a Z-Wave device that can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway), it can be controlled by other Z-Wave devices to turn on/off loads, it can bear up to 16A current of resistive loads. It also acts as a repeater that forwards Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node. +By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary “listening” Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. +Also a tool that can be programmed, scheduled, controlled and communicated with from anywhere in the world. + + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + ZW075-C16 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1056/Aeon Labs Smart Switch Gen5_Update 2.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1045/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1053/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1056/xml + + https://products.z-wavealliance.org/products/1053/ + ZW075-A02 + U.S. / Canada / Mexico + https://products.z-wavealliance.org/products/1056/ + Australia / New Zealand + ZW075-B09 + + + + + + + + + Configuration Value 1: 1-255 + Configuration Value 1 is to Specify the time that Smart Switch need blink, The unit is Second; + Configuration Value 2: 1-255 + Configuration Value 2 is to Specify the Cycle of on/off, the unit of it is 0.1 second. + + + + Load will be closed when the Current overruns (EU 16.2A) for more than 2 minutes + + + + + Configure the output load status after re-power on. + + + + + + Defines the automated status notification of an associated device when status changes + + + + + + + + + + Enable/disable Wattage threshold and percent. + + + The value represents the minimum change in wattage for a Report to be sent (default 25 W) + + + The value represents the minimum percentage change in wattage for a Report to be sent (Default 5) + + + Set report types for groups 1, 2 and 3 to default. + + + + Defines the type of report sent for reporting group 1. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 kWh + bit 2 watt + bit 1 current + bit 0 voltage + + + + + Defines the type of report sent for reporting group 2. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 kWh + bit 2 watt + bit 1 current + bit 0 voltage + + + + + Defines the type of report sent for reporting group 3. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 kWh + bit 2 watt + bit 1 current + bit 0 voltage + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + Defines the time interval when the defined report for group 1 is sent. + + + Defines the time interval when the defined report for group 2 is sent. + + + Defines the time interval when the defined report for group 3 is sent. + + + Partner ID + + + + + Enable/disable Configuration Locked + + + + + Device tag. + + + Reset to the default configuration. + + + + + + + + + + diff --git a/openzwave/aeotec/zw078.xml b/openzwave/aeotec/zw078.xml new file mode 100644 index 00000000..2c536f4c --- /dev/null +++ b/openzwave/aeotec/zw078.xml @@ -0,0 +1,158 @@ + + + http://www.openzwave.com/device-database/0086:004E:0103 + images/aeotec/zw078.png + https://products.z-wavealliance.org/products/1133/ + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + N/A + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1142/Heavy Duty Smart Switch Gen5 Manual.pdf + Aeon Labs Heavy Duty Smart Switch is a Z-Wave device that can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway), it can be controlled by other Z-Wave devices to turn on/off loads, it can bear up to 40A current of resister loads. It also acts as a repeater that forward Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node. +By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary “listening” Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. + + + Heavy Duty Smart Switch Gen5 + ZW078-A + U.S. / Canada / Mexico + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/998/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1089/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1133/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1142/xml + + https://products.z-wavealliance.org/products/1089/ + ZW078-B + Australia / New Zealand + https://products.z-wavealliance.org/products/1142/ + CEPT (Europe) + ZW078-C + + + + + + + Current Overload Protection. Load will be closed when + the Current more than 39.5A and the time more than 5 + seconds + + + + + + LED status after power on + + + + + + + Enables automatic notifications to associated devices whenever there is a state change. + + + + + + + Enable/disable Wattage threshold and percent. + + + The minimum change in wattage for a report to be sent. + + + Minimum change in percent of wattage to send a report. + + + Set report types for groups 1, 2 and 3 to default. + + + + Defines the type of report sent for reporting group 1. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 kWh + bit 2 watt + bit 1 current + bit 0 voltage + + + + + Defines the type of report sent for reporting group 2. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 kWh + bit 2 watt + bit 1 current + bit 0 voltage + + + + + Defines the type of report sent for reporting group 3. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 kWh + bit 2 watt + bit 1 current + bit 0 voltage + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + Defines the time interval when the defined report for group 1 is sent. + + + Defines the time interval when the defined report for group 2 is sent. + + + Defines the time interval when the defined report for group 3 is sent. + + + + + + + Lock/ unlock all configuration parameters + + + + + Reset to factory defaults + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw080.xml b/openzwave/aeotec/zw080.xml new file mode 100644 index 00000000..36ad52c8 --- /dev/null +++ b/openzwave/aeotec/zw080.xml @@ -0,0 +1,91 @@ + + + http://www.openzwave.com/device-database/0086:0050:0104 + images/aeotec/zw080.png + https://products.z-wavealliance.org/products/1134/ + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + N/A + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + ZW080-A17 + Aeon Labs Siren Gen5 is an siren Z-Wave device that when an emergency is happening it lets you know. Its 105dB Speaker System is always heard. Its super-bright LED system lights your path even when it’s dark. Siren provides a smart home with the perfect security and safety features that it needs. +Those security and safety features are matched by smart features. Siren’s speaker system can access 5 different audio alerts, allowing your smart home to pick the alert best suited to the emergency. The speaker system’s volume can also be adjusted so that Siren is perfect for every space in every home. +It also act as a repeater that forward Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node. +By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary “listening” Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. +Also a tool that can be programmed, scheduled, controlled and communicated with from anywhere in the world. + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + Siren Gen5 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1141/Siren Gen5 Manual.pdf + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1134/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1136/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1141/xml + + https://products.z-wavealliance.org/products/1136/ + ZW080-C15 + CEPT (Europe) + https://products.z-wavealliance.org/products/1141/ + Australia / New Zealand + ZW080-B21 + + + + + + Select the Siren Sound and Volume + + + + + + + + + + + + + + + + + + Enable/disable to turn off the alarm sound via pressing the Action Button. + + + + + Enable to send notifications to associated devices (Group 1) when the state of Siren changed + + + + + + Partner ID + + + + Enable/disable Lock Configuration + + + + + Reset to factory defaults + + + + + + + + + true + + + + + + + + + diff --git a/openzwave/aeotec/zw088.xml b/openzwave/aeotec/zw088.xml new file mode 100644 index 00000000..ac1284aa --- /dev/null +++ b/openzwave/aeotec/zw088.xml @@ -0,0 +1,57 @@ + + + http://www.openzwave.com/device-database/0086:0058:0101 + images/aeotec/zw088.png + https://products.z-wavealliance.org/products/1165/ + Press and hold the "Learn" for 3 seconds will trigger sending the Wake up notification command. + Short press the “Exclude” button on the Key Fob, it will go into exclusion state and its red LED will blink slowly to wait excluding other slave Z-Wave devices from its network. + Use this procedure only in the event that the primary controller is missing or otherwise inoperable. + +Press and hold the “Mode” button and “Learn” button for 20 seconds and then release. + Key Fob Gen5 is a fully functional Z-wave remote controller, which can include, exclude and control the other Z-Wave certified devices. It also can be acted a secondary controller in a network. + +It is a four buttons design. You can use each button to control your home’s Z-Wave devices and build a Z-Wave network for them. + +Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. + + ZW088-A + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1178/Instructions - Aeon Labs Key Fob Gen5 MCert.pdf + Key Fob Gen5 + Short press the “Include” button on the Key Fob, it will go into inclusion state and its blue LED will blink slowly to wait including other slave Z-Wave devices. + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1165/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1177/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1178/xml + + https://products.z-wavealliance.org/products/1177/ + Australia / New Zealand + ZW088-B + https://products.z-wavealliance.org/products/1178/ + ZW088-C + CEPT (Europe) + + + + + + + + + Enable selective Group Mode or Scene Mode when the Key Fob is in Use mode + + + + + Reset configuration set up to default setting + + + + + + + + + diff --git a/openzwave/aeotec/zw089.xml b/openzwave/aeotec/zw089.xml new file mode 100644 index 00000000..17b7a2a0 --- /dev/null +++ b/openzwave/aeotec/zw089.xml @@ -0,0 +1,99 @@ + + + http://www.openzwave.com/device-database/0086:0059:0102 + images/aeotec/zw089.png + https://products.z-wavealliance.org/products/1179/ + Recessed Door Sensor Gen5 + Press and hold the Z-Wave button for 5 seconds will trigger sending the Wake up notification command and then keep waking up for 10 seconds after release the Z-Wave button. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1184/Recessed Door Sensor Gen5 - Manual MCert.pdf + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Z-Wave button that you can find in the back of the product. + U.S. / Canada / Mexico + ZW089-A + Press and hold the Z-Wave button that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Z-Wave button that you can find in back of the product. + The Aeotec by Aeon Labs Recessed Door Sensor Gen5 is a door sensor that can detect the state of the door's open/close. It will report the door state to your controller/ gateway/associated nodes in real time when the state of your door has a change. +It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs. +It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1179/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1183/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1184/xml + + https://products.z-wavealliance.org/products/1183/ + Australia / New Zealand + ZW089-B + https://products.z-wavealliance.org/products/1184/ + CEPT (Europe) + ZW089-C + + + + + + + Which value of the Sensor Binary Report will be sent when + the magnet switch to open/close. + + + + + Which value of the Basic Set will be sent when the magnet + switch to open/close. + + + + + + Enable/disable the function of low battery checking, when + the current voltage is less than the warning voltage, it will + send the Battery Low Warning Report. + + + + + + This parameter is available when the low battery checking + function is activated or the device was waked up by other + actions (i.e. the z-wave button trigger, magnet switch + trigger and the Wake Up Interval Set timeout trigger). + The Recessed Door Sensor will check the battery power + when it was wake up as other ways. For example: the + z-wave button trigger, magnet switch trigger and the + Wake Up Interval Set timeout trigger. + Default setting: 86640 + + + + Configure which sensor report will be sent when the sensor is Opened/Closed + + + + + + + Lock/ unlock all configuration parameters + + + + + Device Tag + + + Reset to factory defaults. + + + + + + true + + + + + + + + + + diff --git a/openzwave/aeotec/zw090.xml b/openzwave/aeotec/zw090.xml new file mode 100644 index 00000000..e62677c5 --- /dev/null +++ b/openzwave/aeotec/zw090.xml @@ -0,0 +1,72 @@ + + + http://www.openzwave.com/device-database/0086:005A:0101 + images/aeotec/zw090.png + https://products.z-wavealliance.org/products/1345/ + Z-Stick Gen5 + Aeotec Z-Stick Gen5 is a USB controller. When connected to a host controller via USB, it enables the host controller to take part in the Z-Wave network. + +Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. + + Use this procedure only in the event that the primary controller is missing or otherwise inoperable. + +Press and hold the Action Button on Z-Stick for 20 seconds and then release. + ZW090-A + Plug the Z-Stick into USB port of your host Controller and then click the “Exclusion” button on your PC/host Controller application. + Plug the Z-Stick into USB port of your host Controller and then click the “Inclusion” button on your PC/host Controller application. + N/A + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1355/Z Stick Gen5 manual 1.pdf + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1345/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1351/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1355/xml + + https://products.z-wavealliance.org/products/1351/ + Australia / New Zealand + ZW090-B + https://products.z-wavealliance.org/products/1355/ + CEPT (Europe) + ZW090-C + + + + + Enable/Disable LED indicator when plugged in + Activer / désactiver l'indicateur LED lorsqu'il est branché + + + + + + 1~10, other= ignore. + A total of 10 levels, level 1 as the weak output power, and so on, 10 for most output power level + + + + + + + + + + + + + + + + + + + + + Lock/ unlock all configuration parameters + + + + + Reset to the default configuration + + + diff --git a/openzwave/aeotec/zw095.xml b/openzwave/aeotec/zw095.xml new file mode 100644 index 00000000..6934b2bf --- /dev/null +++ b/openzwave/aeotec/zw095.xml @@ -0,0 +1,254 @@ + + + http://www.openzwave.com/device-database/0086:005F:0102 + images/aeotec/zw095.png + https://products.z-wavealliance.org/products/1289/ + Press and hold the Action button that you can find on the product's housing for 10 seconds and then release. This procedure should only be used when the primary controller is inoperable. + U.S. / Canada / Mexico + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + Aeon Labs Home Energy Meter Gen5 is a Z-Wave device that can monitor the total amount of electricity of your home. +It can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway). In near real-time you’ll have a full understanding of how much electricity you use and when you use it. +Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. Also a tool that can be programmed, scheduled, controlled and communicated with from anywhere in the world. + ZW095-A + N/A + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2046/Home Energy Meter Gen5 manual.pdf + Home Energy Meter Gen5 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1289/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1596/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2046/xml + + https://products.z-wavealliance.org/products/2046/ + CEPT (Europe) + ZW095-C + + + + + For parameters of 101 ~ 103, power, energy detection mode configuration + + + + + + + + Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic. + + + + + + + Threshold change in wattage to induce a automatic report (whole HEM). + + + + + Threshold change in wattage to induce a automatic report (Clamp 1). + + + + + Threshold change in wattage to induce a automatic report (Clamp 2). + + + + + Threshold change in wattage to induce a automatic report (Clamp 3). + + + + + Percentage change in wattage to induce a automatic report (whole HEM). + + + + + Percentage change in wattage to induce a automatic report (Clamp 1). + + + + + Percentage change in wattage to induce a automatic report (Clamp 2). + + + + + Percentage change in wattage to induce a automatic report (Clamp 3). + + + + + Enable /disable reporting CRC-16 Encapsulation Command. + + + + + + + Reset to default parameters number 101-103. Any value other then 0 will initiate this reset. + + + + + Which reports need to send in group1. Format is as follows: + Byte 1 (msb): + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for kVar) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kVar) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kVar) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for KVah) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for KVah) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for KVah) at the group time interval (Clamp 1) + Byte 2: + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for A) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for A) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for A) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for V) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for V) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for V) at the group time interval (Clamp 1) + Byte 3: + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for Watt) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for Watt) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for Watt) at the group time interval (Clamp 1) + Byte 4 (lsb): + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for kVar) at the group time interval (Whole HEM) + Bit 4: Auto Send Meter Report (for KVah) at the group time interval (Whole HEM) + Bit 3: Auto Send Meter Report (for A) at the group time interval (Whole HEM) + Bit 2: Auto Send Meter Report (for V) at the group time interval (Whole HEM) + Bit 1: Auto Send Meter Report (for Watt) at the group time interval (Whole HEM) + Bit 0: Auto Send Meter Report (for kWh) at the group time interval (Whole HEM) + + + + + Which reports need to send in group2. Format is as follows: + Byte 1 (msb): + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for kVar) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kVar) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kVar) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for KVah) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for KVah) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for KVah) at the group time interval (Clamp 1) + Byte 2: + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for A) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for A) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for A) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for V) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for V) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for V) at the group time interval (Clamp 1) + Byte 3: + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for Watt) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for Watt) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for Watt) at the group time interval (Clamp 1) + Byte 4 (lsb): + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for kVar) at the group time interval (Whole HEM) + Bit 4: Auto Send Meter Report (for KVah) at the group time interval (Whole HEM) + Bit 3: Auto Send Meter Report (for A) at the group time interval (Whole HEM) + Bit 2: Auto Send Meter Report (for V) at the group time interval (Whole HEM) + Bit 1: Auto Send Meter Report (for Watt) at the group time interval (Whole HEM) + Bit 0: Auto Send Meter Report (for kWh) at the group time interval (Whole HEM) + + + + + Which reports need to send in group3. Format is as follows: + Byte 1 (msb): + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for kVar) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kVar) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kVar) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for KVah) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for KVah) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for KVah) at the group time interval (Clamp 1) + Byte 2: + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for A) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for A) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for A) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for V) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for V) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for V) at the group time interval (Clamp 1) + Byte 3: + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3) + Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2) + Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1) + Bit 2: Auto Send Meter Report (for Watt) at the group time interval (Clamp 3) + Bit 1: Auto Send Meter Report (for Watt) at the group time interval (Clamp 2) + Bit 0: Auto Send Meter Report (for Watt) at the group time interval (Clamp 1) + Byte 4 (lsb): + Bit 7: Reserved + Bit 6: Reserved + Bit 5: Auto Send Meter Report (for kVar) at the group time interval (Whole HEM) + Bit 4: Auto Send Meter Report (for KVah) at the group time interval (Whole HEM) + Bit 3: Auto Send Meter Report (for A) at the group time interval (Whole HEM) + Bit 2: Auto Send Meter Report (for V) at the group time interval (Whole HEM) + Bit 1: Auto Send Meter Report (for Watt) at the group time interval (Whole HEM) + Bit 0: Auto Send Meter Report (for kWh) at the group time interval (Whole HEM) + + + + Reset to default parameters number 111-113 + + + The interval of sending report group 1. + + + The interval of sending report group 2 + + + The interval of sending report group 3 + + + + + + + Lock/ unlock all configuration parameters + + + + + Reset to factory defaults + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw096.xml b/openzwave/aeotec/zw096.xml new file mode 100644 index 00000000..5320115d --- /dev/null +++ b/openzwave/aeotec/zw096.xml @@ -0,0 +1,183 @@ + + + http://www.openzwave.com/device-database/0086:0060:0103 + images/aeotec/zw096.png + https://products.z-wavealliance.org/products/3093/ + Smart Switch 6 + N/A + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + Aeotec Smart Switch 6 is a low-cost Z-Wave Switch plug-in module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. +Its surface has a Smart RGB LED, which can be used for indicating the output load status or strength of the wireless signal. You can configure its indication colour according to your favour. +The Plug is also a security Z-wave device and supports Over The Air (OTA) feature for the products firmware upgrade. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3119/Instructions - Aeon Labs Smart Switch 6 (2).pdf + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + U.S. / Canada / Mexico + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + ZW096-A02 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1312/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1331/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1425/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3093/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3104/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3119/xml + + https://products.z-wavealliance.org/products/3119/ + Australia / New Zealand + ZW096-B09 + https://products.z-wavealliance.org/products/3104/ + CEPT (Europe) + ZW096-C16 + + + + + + + Load will be closed when the Current overruns (US 15.5A, Others 16.2) for more than 2 minutes + + + + + Configure the output load status after re-power on. + + + + + + Configure the RGB Led Color for Testing + + + + + + + Defines the automated status notification of an associated device when status changes + + + + + + + + + + + Configure the RGB Value when in Night Light Mode. + Byte 1: Red Color + Byte 2: Green Color + Byte 3: Blue Color + + + + Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/momentary indicate mode. + Byte 1: Red Color + Byte 2: Green Color + Byte 3: Blue Color + + + + + Enable/disable Wattage threshold and percent. + + + + The value represents the minimum change in wattage for a Report to be sent (default 25 W) + + + The value represents the minimum percentage change in wattage for a Report to be sent (Default 5) + + + + Set report types for groups 1, 2 and 3 to default. + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 KWH + bit 2 Watt + bit 1 Current + bit 0 Voltage + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 KWH + bit 2 Watt + bit 1 Current + bit 0 Voltage + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 KWH + bit 2 Watt + bit 1 Current + bit 0 Voltage + + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + + + Defines the time interval when the defined report for group 1 is sent. + + + + + Defines the time interval when the defined report for group 2 is sent. + + + + + Defines the time interval when the defined report for group 3 is sent. + + + + Partner ID + + + + + Enable/disable Configuration Locked + + + + + + Device tag. + + + + + Reset to the default configuration. + + + + + + + + + + + diff --git a/openzwave/aeotec/zw097.xml b/openzwave/aeotec/zw097.xml new file mode 100644 index 00000000..73e74a18 --- /dev/null +++ b/openzwave/aeotec/zw097.xml @@ -0,0 +1,84 @@ + + + http://www.openzwave.com/device-database/0086:0061:0102 + images/aeotec/zw097.png + https://products.z-wavealliance.org/products/1495/ + Dry Contact Sensor Gen5 + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action Button that you can find in the back of the product. + U.S. / Canada / Mexico + ZW097-A + Press the Action Button once that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1495/Dry Contact Sensor Gen5 manual.pdf + Aeon Labs Dry Contact Sensor Gen5 is a dry conatct sensor that can detect a variety of dry contact signals, you just need to connect the matched external sensor on it, such as the water level sensor, dry contact switch, dry contact relay and so on. In other words, it can be used if the external sensor is a dry contact. +It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs. +It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications. + + Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes. + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action Button that you can find in back of the product. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1495/xml + + + + + + Which value of the Sensor Binary Report will be sent when the door is Opened/Closed + + + + + Enable/disable wake up 10 minutes when re-power on the Sensor. + Default setting: Enable + + + + + Which value of the Basic Set will be sent when the door is Opened/Closed + + + + + 10% to 50% + + + + Set the interval time of battery report. + Value=0, disable the battery report for a interval time. + Value=1 to 0x7FFFFFFF, the interval time of battery report is set. + Note: + 1, if the value is less than 10, the time unit is second. + If the value is more than 10, the time unit is 4 minutes, which means if the value is more than 10 and less than 240, the interval time is 4 minutes. + If the value is more than 240 and less than 480, the interval is 8 minutes. + 2, if the current battery report falls below the low battery value (configurable parameter 39), it will send battery report=0xFF. + + + + Configure which sensor report will be sent when the sensor is Opened/Closed + + + + + + + Reset to factory defaults + + + + + + + + + true + + + + + + + + + diff --git a/openzwave/aeotec/zw098.xml b/openzwave/aeotec/zw098.xml new file mode 100644 index 00000000..5a59f3a9 --- /dev/null +++ b/openzwave/aeotec/zw098.xml @@ -0,0 +1,126 @@ + + + http://www.openzwave.com/device-database/0086:0062:0103 + images/aeotec/zw098.png + https://products.z-wavealliance.org/products/1829/ + Aeotec LED Bulb is a low-cost Z-Wave LED module which allows control (on/off/dim) with the use of Z-Wave. +It’s a bulb has a Smart RGB LED, which can be used to add colour to your home. The bulb has 5 main colour channels available for you to adjust: Red, Green, Blue, Warm White and Cold White. You can configure its colour according to your favour. +The LED Bulb is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1851/LED Bulb manual.pdf + Turn the primary controller of Z-Wave network into exclusion mode, press the external switch of LED Bulb to turn off and then press the external switch again to turn on it, repeat the operation 3 times. + ZW098-A52 + U.S. / Canada / Mexico + Turn the primary controller of Z-Wave network into inclusion mode, press the external switch of LED Bulb to turn it off and then press the external switch again to turn it on. + N/A + LED Bulb + Turn the controller of Z-Wave network into exclusion mode, press the external switch of LED Bulb to turn off and then press the external switch again to turn on it, repeat the operation 3 times. +After the LED Bulb is excluded from network, it will be reset to factory default state. +Use this procedure only in the event that your primary network controller is missing or inoperable. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1315/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1368/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1379/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1380/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1594/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1829/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1844/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1851/xml + + https://products.z-wavealliance.org/products/1844/ + Australia / New Zealand + ZW098-B55 + https://products.z-wavealliance.org/products/1851/ + CEPT (Europe) + ZW098-C55 + + + + + + The Bulb state after re-power on it. + + + + + + Enable/disable to send out a report when the color is changed + + + + + + Value 1 = Reserved. + Value 2 = Red color value. + Value 3 = Green color value. + Value 4 = Blue color value. + Note: This parameter is a get-only parameter + + + + Enable/disable the function of using External Switch to turn on/off the bulb + + + + + Enable/disable the function of using External Switch to changes the bulb color + + + + + Reboot/save/exit Colorful mode + + + + + + + Colorful mode configuration (See https://aeotec.freshdesk.com/helpdesk/attachments/6035749140) + + + + Value 1: the speed from OFF to ON. + Value 2: the speed from ON to OFF. + Value 3: pause time of ON. + Value 4: pause time of OFF. + + + + Color index configuration when the bulb is in Multi color mode (See https://aeotec.freshdesk.com/helpdesk/attachments/6035749140) + + + Enable to send notifications to associated devices (Lifeline) when the state of LED Bulb is changed + + + + + + Enable to send notifications to associated devices (Lifeline) when the state of LED Bulb is changed + + + + + + + Lock/ unlock all configuration parameters + + + + + Reset to factory defaults + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw099.xml b/openzwave/aeotec/zw099.xml new file mode 100644 index 00000000..3b2f58d1 --- /dev/null +++ b/openzwave/aeotec/zw099.xml @@ -0,0 +1,199 @@ + + + http://www.openzwave.com/device-database/0086:0063:0103 + images/aeotec/zw099.png + https://products.z-wavealliance.org/products/2246/ + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + ZW099-A02 + Smart Dimmer 6 + U.S. / Canada / Mexico + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2246/Aeon Labs Smart Dimmer 6 manual.pdf + Aeotec Smart Dimmer 6 is a low-cost Z-Wave Dimmer plug-in module specifically used to enable Z-Wave command and control (on/off/dim) of any plug-in tool. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. +Its surface has a Smart RGB LED, which can be used for indicating the output load status or strength of the wireless signal. You can configure its indication colour according to your favour. +The Smart Dimmer 6 is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1515/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1519/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2246/xml + + https://products.z-wavealliance.org/products/1519/ + ZW099-C16 + CEPT (Europe) + + + + + + + + Load will be closed when the Current overruns (US 15.5A, Others 16.2) for more than 2 minutes + + + + + Configure the output load status after re-power on. + + + + + + + Defines the automated status notification of an associated device when status changes + + + + + + Configure what the LED Ring displays during operations + + + + + + Configure the RGB Value when in Night Light Mode. + Byte 1: Red Color + Byte 2: Green Color + Byte 3: Blue Color + + + + Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/momentary indicate mode. + Byte 1: Red Color + Byte 2: Green Color + Byte 3: Blue Color + + + + + Enable/disable Wattage threshold and percent. + + + + The value represents the minimum change in wattage for a Report to be sent (default 25 W) + + + The value represents the minimum percentage change in wattage for a Report to be sent (Default 5) + + + + Set report types for groups 1, 2 and 3 to default. + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) + bits 7-4 reserved + bit 3 KWH + bit 2 Watt + bit 1 Current + bit 0 Voltage + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) + bits 7-4 reserved + bit 3 KWH + bit 2 Watt + bit 1 Current + bit 0 Voltage + + + + + Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) + bits 7-4 reserved + bit 3 KWH + bit 2 Watt + bit 1 Current + bit 0 Voltage + + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + + + Defines the time interval when the defined report for group 1 is sent. + + + + + Defines the time interval when the defined report for group 2 is sent. + + + + + Defines the time interval when the defined report for group 3 is sent. + + + + Partner ID + + + + + Enable/disable Configuration Locked + + + + + + Device tag. + + + + + Reset to the default configuration. + + + + + + true + true + + + + + + + + + + diff --git a/openzwave/aeotec/zw100.xml b/openzwave/aeotec/zw100.xml new file mode 100644 index 00000000..03381caa --- /dev/null +++ b/openzwave/aeotec/zw100.xml @@ -0,0 +1,456 @@ + + + http://www.openzwave.com/device-database/0086:0064:0102 + images/aeotec/zw100.png + https://products.z-wavealliance.org/products/2684/ + U.S. / Canada / Mexico + Pressing the Z-Wave button once will trigger sending the Wake up notification command. If press and hold the Z-Wave button for 3 seconds, the MultiSensor will wake up for 10 minutes. + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Z-Wave button that you can find in the back of the product. + ZW100-A + MultiSensor 6 + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Z-Wave button that you can find in back of the product. + Aeotec MultiSensor 6 looks like a motion sensor and it acts like one too. But it’s also so much more. Installing this 1 piece of Z-Wave® technology is the same as installing 6 pieces of Z-Wave technology. Your home control network will immediately understand motion, temperature, humidity, light, Ultraviolet and Vibration readings wherever MultiSensor installed. Those intelligent readings will equate to intelligence automation. And intelligent automation will give you the perfect, smart home. + Press and hold the Z-Wave button that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2714/Aeon Labs MultiSensor 6 manual.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1390/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1403/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1404/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1810/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1812/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2684/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2695/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2714/xml + + https://products.z-wavealliance.org/products/2714/ + ZW100-C + CEPT (Europe) + https://products.z-wavealliance.org/products/2695/ + ZW100-B + Australia / New Zealand + + + + Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor + + + + + + + Duration that the motion sensor must observe no motion before it will return to the no-motion state. + If value greater than 255, effective value is rounded up to the nearest minute (255 -> 255 seconds, 256 -> 300 seconds) + + + Enable Motion Sensor, (1 minimum, 5 maximum sensitivity level) + + + + + + + + + Which commands to send when PIR motion sensor triggered + OZW Ideal Value is Binary Sensor Report + + + + + + Set the timeout of awake after the Wake Up CC is sent out. + Available rang: 8 to 255 seconds. + + + + Report the current power mode and the product state for battery power mode + + + + + + + Configure low battery value + Value=10 to 50. + + + Enable/disable the selective reporting only when measurements reach a certain threshold or percentage + set in the threshold settings. This is used to reduce network + traffic. + + + + + Threshold change in temperature to induce an automatic report. + Note: + 1. The unit is Fahrenheit for US version, Celsius for EU/AU version. + 2. The value contains one decimal point. E.g. if the value is set to 20, the threshold value = 2.0 C (EU/AU) or 2.0 F (US). When the temperature has changed by 2.0 (of the appropriate unit), a temperature report will be sent. + + + + Threshold change in humidity to induce an automatic report. + Note: + 1. The unit is %. + 2. The default value is 10, which means that a 10% change in humidity will trigger a report. + + + + Threshold change in luminance to induce an automatic report. + + + Threshold change in battery level to induce an automatic report. + Note: + 1. The unit is %. + 2. The default value is 10, which means that a 10% change in battery will trigger a report. + + + + Threshold change in ultraviolet to induce an automatic report. + + + + Enable/disable to send the alarm report of low temperature(Less than 15 Degress C) + + + + + + + Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. + Note: + If USB power, the Sensor will check the limit every 10 seconds. If battery power, the Sensor will check the limit when it is waken up. + + French Help + + + + + Lower Temperature Threshold + Lower Temperature Threshold-fr + + + + + Lower Humdity Threshold + Lower Humdity Threshold-fr + + + + + Lower Luminance Threshold + Lower Luminance Threshold + + + + + Lower Ultraviolet Threshold + Lower Ultraviolet Threshold-fr + + + + + Upper Temerature Threshold + Upper Temerature Threshold-fr + + + + + Upper Humdity Threshold + Upper Humdity Threshold-fr + + + + + Upper Luminance Threshold + Upper Luminance Threshold-fr + + + + + Upper Ultraviolet Threshold + Upper Ultraviolet Threshold-fr + + + + + When the measurement is more than this upper limit, which will trigger to sent out a sensor report. + High byte is the upper limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). + 1. When unit is Celsius. + Upper limit range: -40.0 to 100.0 C (0xFE70 to 0x03E8). + E.g. The default upper limit of EU/AU version is 28.0 C (0x0118), when the measurement is more than 28.0C, it will be triggered to send out a temperature sensor report. + 2. When unit is Fahrenheit. + Upper limit range: -40.0 to 212.0 F (0xFE70 to 0x0848). + E.g. The default upper limit of US version is 82.4F (0X0338), when the measurement is more than 82.4F, it will be triggered to send out a temperature sensor report. + + + + + When the measurement is less than this lower limit, which will trigger to sent out a sensor report. + High byte is the lower limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). + 1. When unit is Celsius. + Lower limit range: -40.0 to 100.0 C (0xFE70 to 0x03E8). + E.g. The default lower limit of EU/AU version is 0 C (0x0000), when the measurement is less than 0C, it will be triggered to send out a temperature sensor report. + 2. When unit is Fahrenheit. + Upper limit range: -40.0 to 212.0 F (0xFE70 to 0x0848). + E.g. The default lower limit of US version is 32.0F (0x0140), when the measurement is less than 32.0F, it will be triggered to send out a temperature sensor report. + + + + + When the measurement is more than this upper limit, which will trigger to sent out a sensor report. + Upper limit range: 0 to 100%. + E.g. The default upper limit is 60%, when the measurement is more than 60%, it will be triggered to send out a humidity sensor report. + + + + + When the measurement is less than this lower limit, which will trigger to sent out a sensor report. + Lower limit range: 0 to 100%. + E.g. The default lower limit is 50%, when the measurement is less than 50%, it will be triggered to send out a humidity sensor report. + + + + + When the measurement is more than this upper limit, which will trigger to sent out a sensor report. + Upper limit range: 0 to 30000 Lux. + E.g. The default upper limit is 1000Lux, when the measurement is more than 1000Lux, it will be triggered to send out a Lighting sensor report. + + + + + When the measurement is less than this lower limit, which will trigger to sent out a sensor report. + Lower limit range: 0 to 30000 Lux. + E.g. The default lower limit is 100Lux, when the measurement is less than 100Lux, it will be triggered to send out a Lighting sensor report. + + + + + When the measurement is more than this upper limit, which will trigger to sent out a sensor report. + Upper limit range: 1 to 11. + E.g. The default upper limit is 8, when the measurement is more than 8, it will be triggered to send out a ultraviolet sensor report. + + + + + When the measurement is less than this upper limit, which will trigger to sent out a sensor report. + Lower limit range: 1 to 11. + E.g. The default lower limit is 4, when the measurement is less than 8, it will be triggered to send out a ultraviolet sensor report. + + + + + Note: + 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. + After that, the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). + 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. + After that, the lower limit report would be disabled again until the measurement greater or equal (Lower limit + Recover limit). + 3. High byte is the recover limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). + 4. Recover limit range: 1.0 to 25.5 C/ F (0x0101 to 0xFF01 or 0x0102 to 0xFF02). + E.g. The default recover limit value is 2.0 C/F (0x1401/0x1402), when the measurement is less than (Upper limit - 2), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 2), the lower limit report would be enabled one time. + + + + + Note: + 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. + After that the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). + 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. + After that the lower limit report would be disabled again until the measurement greater or equal(Lower limit + Recover limit). + 3. Recover limit range: 1 to 50% (0x01 to 0x32). + E.g. The default recover limit value is 5%, when the measurement is less than (Upper limit - 5), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 5), the lower limit report would be enabled one time. + + + + + Note: + 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. + After that the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). + 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. + After that the lower limit report would be disabled again until the measurement greater or equal (Lower limit + Recover limit). + 3. Unit = 10*Recover limit (Lux) + 4. Recover limit range: 10 to 2550Lux (0x01 to 0xFF). + E.g. The default recover limit value is 100 Lux, when the measurement is less than (Upper limit - 100), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 100), the lower limit report would be enabled one time. + + + + + Note: + 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. + After that the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). + 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. + After that the lower limit report would be disabled again until the measurement greater or equal(Lower limit + Recover limit). + 3. Recover limit range: 1 to 50% (0x01 to 0x32). + E.g. The default recover limit value is 5%, when the measurement is less than (Upper limit - 5), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 5), the lower limit report would be enabled one time. + + + + + Get the out-of-limit state of the Sensors. + Bit mask = 0, within the limit. + Bit mask = 1, out of the limit. + Bit 0 = temperature. + Bit 1 = humidity. + Bit 2 = luminance. + Bit 3 = ultraviolet. + The above bit masks are used to indicate whether the current measurements of the Sensors are out of the lower limit. + The below bit masks are used to indicate whether the current measurements of the Sensors are out of the upper limit. + Bit 4 = temperature. + Bit 5 = humidity. + Bit 6 = luminance. + Bit 7 = ultraviolet. + + + + Default value: Celsius for EU/AU version, Fahrenheit for US version. + + + + + Enable/disable the LED blinking for motion, wakeup, and sensor report. + + + + + + Reset The Reporting Group Configuration (101 to 103) to default + + + Which reports need to send automatically in timing intervals for group 1. + Bitmask: + 10000000 - 128 - Luminance + 01000000 - 64 - Humidity + 00100000 - 32 - Temperature + 00010000 - 16 - Ultraviolet + 00000001 - 1 - Battery + 10100000 - 160 - Luminance and Temperature (32+128) + 11110001 - 241 - All (1+16+32+64+128) + + + + Send Battery Report + + + + Send Ultraviolet Report + + + + Send Temperature Report + + + + Send Humidity Report + + + + Send Luminance Report + + + + Which reports need to send automatically in timing intervals for group 2. + Bitmask: + 10000000 - 128 - Luminance + 01000000 - 64 - Humidity + 00100000 - 32 - Temperature + 00010000 - 16 - Ultraviolet + 00000001 - 1 - Battery + 10100000 - 160 - Luminance and Temperature (32+128) + 11110001 - 241 - All (1+16+32+64+128) + + + Which reports need to send automatically in timing intervals for group 3. + Bitmask: + 10000000 - 128 - Luminance + 01000000 - 64 - Humidity + 00100000 - 32 - Temperature + 00010000 - 16 - Ultraviolet + 00000001 - 1 - Battery + 10100000 - 160 - Luminance and Temperature (32+128) + 11110001 - 241 - All (1+16+32+64+128) + + + Reset The Reporting Group Interval Configuration (111 to 113) to default + + + + The interval for sending reports for group 1. + The effective behavior of this setting depends on the device's power source: + - If the device is on USB power, it will send the reports at the configured interval; set it to something low (~15-60 seconds) to get frequent updates from a powered device. + - If the device is on battery, the sensor will never report in more often than its configured wake interval, regardless of what this setting is configured to; setting this to 3601 when the wake interval is 3600 would make this group report in every 7200 seconds. 240 seconds is the minimum wake interval, but will quickly use battery. + + + The interval for sending reports for group 2. + The effective behavior of this setting depends on the device's power source: + - If the device is on USB power, it will send the reports at the configured interval; set it to something low (~15-60 seconds) to get frequent updates from a powered device. + - If the device is on battery, the sensor will never report in more often than its configured wake interval, regardless of what this setting is configured to; setting this to 3601 when the wake interval is 3600 would make this group report in every 7200 seconds. 240 seconds is the minimum wake interval, but will quickly use battery. + + + The interval for sending reports for group 3. + The effective behavior of this setting depends on the device's power source: + - If the device is on USB power, it will send the reports at the configured interval; set it to something low (~15-60 seconds) to get frequent updates from a powered device. + - If the device is on battery, the sensor will never report in more often than its configured wake interval, regardless of what this setting is configured to; setting this to 3601 when the wake interval is 3600 would make this group report in every 7200 seconds. 240 seconds is the minimum wake interval, but will quickly use battery. + + + Temperature calibration (the available value range is [-128,127] or [-12.8C,12.7C]). + Note: + 1. High byte is the calibration value. Low byte is the unit (0x01=Celsius,0x02=Fahrenheit) + 2. The calibration value (high byte) contains one decimal point. + E.g. if the value is set to 20 (0x1401), the calibration value is 2.0C (EU/AU version) or if the value is set to 20 (0x1402), the calibration value is 2.0F (US version) + 3. The calibration value (high byte) = standard value - measure value. + E.g. If measure value =25.3C and the standard value = 23.2C, so the calibration value= 23.2C - 25.3C= -2.1C (0xEB). + If the measure value =30.1C and the standard value = 33.2C, so the calibration value= 33.2C - 30.1C=3.1C (0x1F). + Default value: 1 for EU/AU version, 2 for US version. + + + + The calibration value = standard value - measure value. + (the available value range is [-50, 50]). + If measure value =80RH and the standard value = 75RH, so the calibration value= 75RH-80RH = -5RH (0xFB). + If the measure value =85RH and the standard value = 90RH, so the calibration value= 90RH-85RH = 5RH (0x05). + + + + The calibration value = standard value - measure value. + (the available value range is [-1000, 1000]). + If measure value =800Lux and the standard value = 750Lux, so the calibration value= 750-800 = -50 (0xFFCE). + If the measure value =850Lux and the standard value = 900Lux, so the calibration value= 900-850 = 50 (0x0032). + + + + The calibration value = standard value measure value. + (the available value range is [-10, 10]). + If measure value =9 and the standard value = 8, so the calibration value= 8-9 = -1 (0xFE). + If the measure value =7 and the standard value = 9, so the calibration value= 9-7 = 2 (0x02). + + + + + Enable/disable Lock Configuration + + + + + + Reset to factory defaults + + + + + + + + + false + + + + + + + + + diff --git a/openzwave/aeotec/zw111.xml b/openzwave/aeotec/zw111.xml new file mode 100644 index 00000000..ee9bddcf --- /dev/null +++ b/openzwave/aeotec/zw111.xml @@ -0,0 +1,364 @@ + + + http://www.openzwave.com/device-database/0086:006F:0103 + images/aeotec/zw111.png + https://products.z-wavealliance.org/products/2095/ + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2149/Aeon Labs Nano Dimmer manual.pdf + Aeotec Nano Dimmer is a Z-Wave Smart Dimmer specifically used to enable Z-Wave command and control (on/off/dim) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. +It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Nano Dimmer. +The Nano Dimmer is also a security Z-Wave plus device and supports Over The Air (OTA) feature for the products firmware upgrade. + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + Nano Dimmer + ZW111-A + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2095/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2135/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2149/xml + + https://products.z-wavealliance.org/products/2135/ + ZW111-C + CEPT (Europe) + https://products.z-wavealliance.org/products/2149/ + Australia / New Zealand + ZW111-B + + + + + Output Load will be turned off automatically after 30 seconds and if the current overrun 1.5A. + + + + + Output load will be closed after 30 seconds if the temperature inside the product exceeds 100C. + + + + + Configure the output load status after re-power on + + + + + + + Enable/disable the IR sensor of WallSwipe. + (LSB) Value 1. + Value 1 = 0, disable the IR Sensor. + Value 1 = 1, enable the IR Sensor. + Value 2 = 0, Wave Option 1 is selected. + Value 2 = 1, Wave Option 2 is selected. + Value 3 = 0, disable the scene control functionality for Left/Right wave. + Value 3 = 1, enable the scene control functionality for Left/Right wave + Value 4 = 0, disable the scene control functionality for all wave actions. + Value 4 = 1, enable the scene control functionality for all wave actions. + + + + + Set the button color of WallSwipe. + Value 1= Level. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is UP. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Down. + Value 1= Level. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Left. + Value 1= Level. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Right. + Value 1= Level. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when it is in Night light state. + Value 1= Level. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the sensitivity of WallSwipe. + + + + To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed + + + + + + + + To set which notification would be sent to the associated nodes in association group 3 when using the external switch 1 to switch the loads + + + + + + To set which notification would be sent to the associated nodes in association group 4 when using the external switch 2 to switch the loads + + + + + + Configure the state of LED when it is in 3 modes below + + + + + + + Value1: Hour of ON. + Value2: Minute of ON. + Value3: Hour of OFF. + Value4: Minute of OFF. + E.g. The default setting is the Night light mode is enabled at 12: 00 and disabled at 8:00 0x12000800. + + + + State appointment + Set the ON time of output load. + Value1 = 0, disable or = non zero, enable (day, bit0 - bit6 represent Mon to Sun). + Value2 = ON (hour) + Value3 = ON (minute) + Value4 = ON (brightness level) + + + + State appointment + Set the ON time of output load. + Value1 = 0, disable or = non zero, enable (day, bit0 - bit6 represent Mon to Sun). + Value2 = ON (hour) + Value3 = ON (minute) + Value4 = ON (brightness level) + + + + Enables/disables parameter 91 and 92 + + + + + The value represents the minimum change in wattage for a Report to be sent (default 25 W) + + + The value represents the minimum percentage change in wattage for a Report to be sent (Default 5) + + + Set report types for groups 1, 2 and 3 to default. + + + + Defines the type of report sent for reporting group 1. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 kWh + bit 2 watt + bit 1 current + bit 0 voltage + + + + + Defines the type of report sent for reporting group 2. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 kWh + bit 2 watt + bit 1 current + bit 0 voltage + + + + + Defines the type of report sent for reporting group 3. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 kWh + bit 2 watt + bit 1 current + bit 0 voltage + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + Defines the time interval when the defined report for group 1 is sent. + + + Defines the time interval when the defined report for group 2 is sent. + + + Defines the time interval when the defined report for group 3 is sent. + + + When the mode is determined, this mode value will not be reset after exclusion + + + + + + + + When the mode is determined, this mode value will not be reset after exclusion + + + + + + + + Get the state of touch panel port + + + + + Set the control destination for external switch S1 + + + + + + Set the control destination for external switch S2 + + + + + + Set the default dimming rate + + + Get the current working mode + + + + + + Set the dimming principle + + + + + To get what type of load the Dimmer is connected to + + + + + + + Set the min brightness level that the load can reach to + + + Set the max brightness level that the load can reach to + + + + Set the working way for S1/S2 when the Switch mode is 2 state switch mode. + Bit 0 =0, S1 is a toggle switch. + Bit 0 =1, S1 is an On/Off switch, the out load state and S1 switch state would be in sync when using S1 to control the output load. + Bit 1 =0, S2 is a toggle switch. + Bit 1 =1, S2 is an On/Off switch, the out load state and S2 switch state would be in sync when using S2 to control the output load. + Bit 2- Bit 7, reserved. + + + + + Set the function of S1/S2. + Bit 0 = 0, the function of sending NIF is disabled. + Bit 0 = 1, the function of sending NIF is enabled. + Bit 1 = 0, the function of entering RF power level test mode is disabled. + Bit 1 = 1, the function of entering RF power level test mode is enabled. + Bit 2 = 0, the function of factory reset is disabled. + Bit 2 = 1, the function of factory reset is enabled. + Bit 3- Bit 6 = reserved. + Bit 7 = 0, the setting for Bit 0 -Bit 2 are ineffective. + Bit 7 = 1, the setting for Bit 0 -Bit 2 are effective. + + + + Set the recognition way of load + + + + + + Enable/disable Configuration Locked + + + + + Reset to factory defaults + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw112.xml b/openzwave/aeotec/zw112.xml new file mode 100644 index 00000000..a65bb5f8 --- /dev/null +++ b/openzwave/aeotec/zw112.xml @@ -0,0 +1,84 @@ + + + http://www.openzwave.com/device-database/0086:0070:0102 + images/aeotec/zw112.png + https://products.z-wavealliance.org/products/1611/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1616/Door Window Sensor 6 manual.pdf + Turn the primary controller into exclusion mode, short press the product’s Action Button that you can find in back of the product. + Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes. + U.S. / Canada / Mexico + Turn the primary controller into inclusion mode, short press the product’s Action Button that you can find in the back of the product. + Aeon Labs Door/ Window Sensor 6 is a smart Z-Wave sensor that can detect the status of door/window's open/close in real time. +It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs. +It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications. + Door/ Window Sensor 6 + Press the Action Button once that you can find in the back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + ZW112-A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1611/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1615/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1616/xml + + https://products.z-wavealliance.org/products/1615/ + CEPT (Europe) + ZW112-C + https://products.z-wavealliance.org/products/1616/ + ZW112-B + Australia / New Zealand + + + + + + + Which value of the Sensor Binary Report or Basic Set will be sent when the door is Opened/Closed + + + + + 10% to 50% + + + Enable/disable the low battery checking + + + + + + The minimum interval is 4 minutes + + + + + Configure which sensor report will be sent when the door is Opened/Closed + + + + + + + + Lock/ unlock all configuration parameters + + + + + Reset to factory defaults + + + + + + + + + true + + + + + + + + + diff --git a/openzwave/aeotec/zw116.xml b/openzwave/aeotec/zw116.xml new file mode 100644 index 00000000..6728ec4b --- /dev/null +++ b/openzwave/aeotec/zw116.xml @@ -0,0 +1,328 @@ + + + http://www.openzwave.com/device-database/0086:0074:0103 + images/aeotec/zw116.png + https://products.z-wavealliance.org/products/2208/ + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + Nano Switch + ZW116-A + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2289/Nano Switch manual.pdf + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + U.S. / Canada / Mexico + Aeotec Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. +It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch. +The Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2208/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2288/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2289/xml + + https://products.z-wavealliance.org/products/2288/ + ZW116-B + Australia / New Zealand + https://products.z-wavealliance.org/products/2289/ + ZW116-C + CEPT (Europe) + + + + + Output load will be closed after 30 seconds if the current exceeds (US: 15.5A, AU or EU: 10.5A). + + + + + Output load will be closed after 30 seconds if the temperature inside the product exceeds 100C. + + + + + Configure the output load status after re-power on + + + + + + + Enable/disable the IR sensor of WallSwipe. + (LSB) Value 1. + Value 1 = 0, disable the IR Sensor. + Value 1 = 1, enable the IR Sensor. + Value 2 = 0, Wave Option 1 is selected. + Value 2 = 1, Wave Option 2 is selected. + Value 3 = 0, disable the scene control functionality for Left/Right wave. + Value 3 = 1, enable the scene control functionality for Left/Right wave + Value 4 = 0, disable the scene control functionality for all wave actions. + Value 4 = 1, enable the scene control functionality for all wave actions. + + + + + Set the button color of WallSwipe. + Value 1= Level 1. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is UP. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Down. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Left. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Right. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when it is in Night light state. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the sensitivity of WallSwipe. + + + + To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed + + + + + + + To set which notification would be sent to the associated nodes in association group 3 when using the external switch 1 to switch the loads + + + + + To set which notification would be sent to the associated nodes in association group 4 when using the external switch 2 to switch the loads + + + + + Configure the state of LED when it is in 3 modes below + + + + + + + Value1: Hour of ON. + Value2: Minute of ON. + Value3: Hour of OFF. + Value4: Minute of OFF. + E.g. The default setting is the Night light mode is enabled at 12: 00 and disabled at 8:00 0x12000800. + + + + + Value1: 0= Disable / 1= Enable. + Value2: Weekday (Bit 0-6 means Monday to Sunday). + Value3: Hour of turning OFF. + Value4: Minute of turning OFF + E.g. The default setting 0x007F1200 + + + + + Value1: 0= Disable / 1= Enable. + Value2: Weekday (Bit 0-6 means Monday to Sunday). + Value3: Hour of turning OFF. + Value4: Minute of turning OFF + E.g. The default setting 0x001707F00 + + + + If this parameter is set to 1 (Enable), the parameter 101 - 103 should be set to 0. + + + + + The value represents the minimum change in wattage for a Report to be sent (default 25 W) + + + The value represents the minimum percentage change in wattage for a Report to be sent (Default 5) + + + Set report types for groups 1, 2 and 3 to default. + + + + Defines the type of report sent for reporting group 1. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 current + bit 2 voltage + bit 1 watt + bit 0 kWh + + + + + Defines the type of report sent for reporting group 2. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 current + bit 2 voltage + bit 1 watt + bit 0 kWh + + + + + Defines the type of report sent for reporting group 3. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 current + bit 2 voltage + bit 1 watt + bit 0 kWh + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + Defines the time interval when the defined report for group 1 is sent. + + + Defines the time interval when the defined report for group 2 is sent. + + + Defines the time interval when the defined report for group 3 is sent. + + + When the switch mode of S1 is determined or identified or configured, this mode value will not be reset after exclusion + + + + + + + + When the switch mode of S2 is determined or identified or configured, this mode value will not be reset after exclusion + + + + + + + + Set the control destination for external switch S1 + + + + + + Set the control destination for external switch S2 + + + + + + Get the state of touch panel port + + + + + Set the working way for S1/S2 when the Switch mode is 3-way switch mode. + + + + + + + + Set the function of S1/S2. + Bit 0 = 0, the function of sending NIF is disabled. + Bit 0 = 1, the function of sending NIF is enabled. + Bit 1 = 0, the function of entering RF power level test mode is disabled. + Bit 1 = 1, the function of entering RF power level test mode is enabled. + Bit 2 = 0, the function of factory reset is disabled. + Bit 2 = 1, the function of factory reset is enabled. + Bit 3 to Bit 6 are reserved. + Bit 7 = 0, the setting for Bit 0 to Bit 2 are ineffective. Bit 7 = 1, the setting for Bit 0 to Bit 2 are effective. + + + + Enable/disable the factory reset function of Action Button, external switches or WallSwipe. + + + + + Enable/disable Configuration Locked + + + + + Reset to factory defaults + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw117.xml b/openzwave/aeotec/zw117.xml new file mode 100644 index 00000000..260c4f78 --- /dev/null +++ b/openzwave/aeotec/zw117.xml @@ -0,0 +1,71 @@ + + + http://www.openzwave.com/device-database/0086:0075:0104 + images/aeotec/zw117.png + https://products.z-wavealliance.org/products/1966/ + U.S. / Canada / Mexico + Turn the primary controller of Z-Wave network into exclusion mode, press the Z-Wave Button on Range Extender 6. + Aeotec Range Extender is a Z-Wave mesh network repeater which can extend the range of communication between Z-Wave products and assist other devices to reach each other in your Z-Wave network. +The Range Extender can also communicate securely via AES 128 wireless Z-Wave commands and supports Over-The-Air (OTA) firmware upgrades. + + Range Extender 6 + Press and hold the Z-Wave Button for 20 seconds and then release it. +Use this procedure only in the event that your primary network controller is missing or inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1998/Range Extender 6 manual.pdf + ZW117-A01 + Turn the primary controller of Z-Wave network into inclusion mode, press the Z-Wave Button on Range Extender 6. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1966/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1994/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1998/xml + + https://products.z-wavealliance.org/products/1994/ + ZW117-B21 + Australia / New Zealand + https://products.z-wavealliance.org/products/1998/ + CEPT (Europe) + ZW117-C15 + + + + + false + + + + + + Set the default status of the LED when the Range Extender relays Z-Wave message. + + + + + Partner ID + + + + + Enable/disable Configuration Locked + + + + + Device tag. + + + Reset to factory defaults + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw120.xml b/openzwave/aeotec/zw120.xml new file mode 100644 index 00000000..2bdb5ade --- /dev/null +++ b/openzwave/aeotec/zw120.xml @@ -0,0 +1,88 @@ + + + http://www.openzwave.com/device-database/0086:0078:0102 + images/aeotec/zw120.png + https://products.z-wavealliance.org/products/1574/ + Aeon Labs Door/ Window Sensor Gen5 is a smart Z-Wave sensor that can detect the status of door/window's open/close in real time. +It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs. +It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications. + + Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes. + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action Button that you can find in the back of the product. + Press the Action Button once that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + ZW120-A + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1579/Door Window Sensor Gen5 manual.pdf + Door/ Window Sensor Gen5 + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action Button that you can find in back of the product. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1574/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1578/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1579/xml + + https://products.z-wavealliance.org/products/1578/ + Australia / New Zealand + ZW120-B + https://products.z-wavealliance.org/products/1579/ + U.S. / Canada / Mexico + ZW120-C + + + + + Which value of the Sensor Binary Report will be sent when the door is Opened/Closed + + + + + Default setting: Disable + + + + + Which value of the Basic Set will be sent when the door is Opened/Closed + + + + + 10% to 50% + + + + Set the interval time of battery report. + Value=0, disable the battery report for a interval time. + Value=1 to 0x7FFFFFFF, the interval time of battery report is set. + Note: + 1, if the value is less than 10, the time unit is second. + If the value is more than 10, the time unit is 4 minutes, which means if the value is more than 10 and less than 240, the interval time is 4 minutes. + If the value is more than 240 and less than 480, the interval is 8 minutes. + 2, if the current battery report falls below the low battery value (configurable parameter 39), it will send battery report=0xFF. + + + + + To configure which sensor report will be sent when the Sensor is triggered Opened/Closed. + Bitsets: 0->Battery report, 4->Sensor Binary, 8->Basic Set, Default setting: 0x00000100 (Basic Set). + Ideal Setting for OZW is 17 (Sensor Binary and Battery Report). + + + + Reset to factory defaults + + + + + + + + + true + + + + + + + + + diff --git a/openzwave/aeotec/zw121.xml b/openzwave/aeotec/zw121.xml new file mode 100644 index 00000000..78a1cc3d --- /dev/null +++ b/openzwave/aeotec/zw121.xml @@ -0,0 +1,130 @@ + + + http://www.openzwave.com/device-database/0086:0079:0103 + images/aeotec/zw121.png + https://products.z-wavealliance.org/products/1963/ + Turn the primary controller of Z-Wave network into inclusion mode, press the Action Button on the LED Strip Controller. + LED Strip + Press and hold the Action Button on the LED Strip Controller for 20 seconds and then release it. +Use this procedure only in the event that your primary network controller is missing or inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2000/LED Strip manual.pdf + Aeotec LED Strip is a multi-coloured LED Strip which allows control (on/off/dim/colour change) via wireless Z-Wave commands. +The LED Strip can also communicate securely via AES 128 wireless Z-Wave commands and supports Over-The-Air (OTA) firmware upgrades. + + U.S. / Canada / Mexico + Turn the primary controller of Z-Wave network into exclusion mode, press the Action Button on the LED Strip Controller. + ZW121-A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1963/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1999/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2000/xml + + https://products.z-wavealliance.org/products/1999/ + Australia / New Zealand + ZW121-B + https://products.z-wavealliance.org/products/2000/ + ZW121-C + CEPT (Europe) + + + + + The LED Strip state after re-power on it. + + + + + + Enable/disable to send out a report when the color is changed + + + + + + Get the LED Strip color value + Value 1: (msb) Reserved + Value 2: Red color value + Value 3: Green color value + Value 4: Blue color value + + + + Enable/disable to turn on the last brightness level of the LED Strip when using the Color Switch Set CC to change its color + + + + + Configure the display mode of Cold/Warm white + + + + + Reboot/save/exit Colorful mode + + + + + + + + Will set the LED Strip into different modes. + See the table in documentation + + + + + Value 1: (msb) The speed from OFF to ON. + Value 2: The speed from ON to OFF. + Value 3: Pause time of ON. + Value 4: Pause time of OFF. + + + + + Can be used to set the 8 color index when the Bulb is in Multi color mode. + See the table in documentation + + + + Reboot/save/exit Colorful mode + + + + + + + + Enable to send notifications to associated devices (Group 1) when the state of LED Strip is changedd + + + + + + + + + + + + + Enable/disable Configuration Locked + + + + + Reset to factory defaults + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw122.xml b/openzwave/aeotec/zw122.xml new file mode 100644 index 00000000..fdd38a6d --- /dev/null +++ b/openzwave/aeotec/zw122.xml @@ -0,0 +1,243 @@ + + + http://www.openzwave.com/device-database/0086:007A:0102 + images/aeotec/zw122.png + https://products.z-wavealliance.org/products/2407/ + Press and hold the Action Button that you can find on the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action Button that you can find on the product. + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action Button that you can find on the product. + Pressing the Action Button once will trigger sending the Wake up notification command. If press and hold the Z-Wave button for 3 seconds, the Water Sensor will wake up for 10 minutes. + Water Sensor 6 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2437/Aeon Labs Water Sensor 6 manual.pdf + ZW122-A + Aeotec by Aeon Labs Water Sensor 6 brings intelligence to a new level, one that is suited to both safety and convenience. It contains 4 sensing points, which would be more accurately to detect the presence and absence of water or detect whether there is water leak in some places of your home. The Water Sensor 6 has an inbuilt buzzer that can play alarm sounds to let you know when the water is detected. + +The Water Sensor 6 is also a security Z-Wave device that supports Over The Air (OTA) for firmware updates. + + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2407/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2411/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2437/xml + + https://products.z-wavealliance.org/products/2411/ + Australia / New Zealand + ZW122-B + https://products.z-wavealliance.org/products/2437/ + ZW122-C + CEPT (Europe) + + + + + false + + + + + + + + Enable/Disable waking up for 10 minutes when re-power on (battery mode) the Water Sensor. + + + + + + Set the timeout of awake after the Wake Up CC is sent out. + Available rang is 8 to 127 seconds. + + + + Report the current power mode and the product state for battery power mode + + + + + + + + + + Set the alarm time for the Buzzer when the sensor is triggered. + 1 to 255 Repeated cycle of Buzzer alarm. + 256 to 65535 the time of Buzzer keeping ON state (MSB). + 65536 to 2147483647 The time of Buzzer keeping OFF state. + + + + 10% to 50% + + + Enable/disable the sensor report: + Bit 7 - Bit 6 - Bit 5 Notification Report for Overheat alarm. + Bit 4 Notification Report for Under heat alarm. + Bit 3 - Bit 2 Configuration Report for Tilt sensor. + Bit 1 Notification Report for Vibration event. + Bit 0 Notification Report for Water Leak event. + Note: if the value = 1+2+4+16+32=55, which means if any sensor will report alarm. + + + + + Set the upper limit value (overheat). + 0 Celsius unit + 1 Fahrenheit unit + 65536 to 2147483647 Temperature value. + Default: 0x01900000 => 40.0C + + + + + Set the lower limit value (under heat). + 0 Celsius unit + 1 Fahrenheit unit + 65536 to 2147483647 Temperature value + + + + + Set the recover limit value of temperature sensor. + Note: + 1. When the current measurement less than or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. + After that the upper limit report would be disabled again until the measurement less than or equal (Upper limit - Recover limit). + 2. When the current measurement greater than or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. + After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit). + 3. High byte is the recover limit value. Low byte is the unit (0x00=Celsius, 0x01=Fahrenheit). + 4. Recover limit range: 1.0 to 25.5 C/F (0x0100 to 0xFF00 or 0x0101 to 0xFF01). + E.g. The default recover limit value is 2.0 C/F (0x1400/0x1401), when the measurement is less than (Upper limit - 2), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 2), the lower limit report would be enabled one time. + + + + Set the default unit of the automatic temperature report in parameter 101-103 + + + + + Get the state of tilt sensor + + + + + Enable/ disable the buzzer. + + + + + What Sensors Trigger the Buzzer + + + If the Water leak is triggered, the buzzer will alarm. + + + + If the vibration is triggered, the buzzer will alarm. + + + + If the Tilt Sensor is triggered, the buzzer will alarm. + + + + If the Under Heat Temperature is triggered, the buzzer will alarm. + + + + If the Over Heat Temperature is triggered, the buzzer will alarm. + + + + To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when the Sensor probe 1 is triggered. + + + + + + To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when the Sensor probe 2 is triggered. + + + + + + To set which power source level is reported via the Battery CC. + + + + + + To set what unsolicited report would be sent to the Lifeline group. + + + + + + + + + To set the interval time of sending reports in Report group 1 + + + + To set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non-multichannel device. + + + + + + + + When the parameter 0x87 is set to 2 or 3, it can get the sensor probes status through this configuration value. + + + + + + + + + Temperature calibration (the available value range is [-128, 127] or [-12.8C, 12.7C]). + Note: + 1. High byte is the calibration value. Low byte is the unit (0x00=Celsius, 0x01=Fahrenheit). + 2. The calibration value (high byte) contains one decimal point. E.g. + if the value is set to 20 (0x1400), the calibration value is 2.0 C (EU/AU version) or if the value is set to 20 (0x1401), the calibration value is 2.0 F(US version). + 3. The calibration value (high byte) = standard value - measure value. + E.g. If measure value =25.3C and the standard value = 23.2C, so the calibration value= 23.2C - 25.3C= -2.1C (0xEB). + If the measure value =30.1C and the standard value = 33.2C, so the calibration value= 33.2C - 30.1C=3.1C (0x1F). + + + + Lock/ unlock all configuration parameters + + + + + Reset to factory defaults + + + + + + + + + true + + + + + true + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw129.xml b/openzwave/aeotec/zw129.xml new file mode 100644 index 00000000..bb3fd1ae --- /dev/null +++ b/openzwave/aeotec/zw129.xml @@ -0,0 +1,123 @@ + + + + http://www.openzwave.com/device-database/0086:0081:0102 + images/aeotec/zw129.png + https://products.z-wavealliance.org/products/2232/ + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2234/Aeon Labs WallMote manual.pdf + WallMote + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + Aeotec WallMote is an intelligent Z-Wave remote controller that mounted on a wall. It has 2 touch buttons that you can easily control the Z-Wave devices in your home network via touching, long pressing or sliding the button areas. +Its surface has a RGB LED to indicate the button actions also accompanied by touch beep and vibration. +The WallMote Quad is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade. + + ZW129-A + U.S. / Canada / Mexico + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2232/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2233/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2234/xml + Remove CentralScene from Endpoints - RemoveCC + + https://products.z-wavealliance.org/products/2233/ + Australia / New Zealand + ZW129-B + https://products.z-wavealliance.org/products/2234/ + ZW129-C + CEPT (Europe) + + + + + false + + + + + + false + + + + + + false + + + + + + This will enable or disable the sound effects when you press or touch the sensing area + + + + + This will enable or disable the vibration effects when you press or touch the sensing area + + + + + This will enable or disable control by sliding the button area + + + + + To configure which report will be sent when pressing the buttons + + + + + + + To configure which color will be displayed when the button is pressed. + Value 1: (msb) Red. + Value 2: Green. + Value 3: Blue. + Value 4: Reserved + + + + + Get the LED Strip color value + Value 1: (msb) Red. + Value 2: Green. + Value 3: Blue. + Value 4: buzzer and vibrator. (1=ON, 0=OFF) + + + + + Set the low battery value. + Range: 10% - 50%. + + + Reset to factory defaults + + + + + + + + + + + + + + + + + + true + + + + + + + diff --git a/openzwave/aeotec/zw130.xml b/openzwave/aeotec/zw130.xml new file mode 100644 index 00000000..0f458107 --- /dev/null +++ b/openzwave/aeotec/zw130.xml @@ -0,0 +1,121 @@ + + + http://www.openzwave.com/device-database/0086:0082:0102 + images/aeotec/zw130.png + https://products.z-wavealliance.org/products/2130/ + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + WallMote Quad + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is missing or inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2153/Aeon Labs WallMote Quad manual.pdf + U.S. / Canada / Mexico + Aeotec WallMote Quad is an intelligent Z-Wave remote controller that mounted on a wall. It has 4 touch buttons that you can easily control the Z-Wave devices in your home network via touching, long pressing or sliding the button areas. +Its surface has a RGB LED to indicate the button actions also accompanied by touch beep and vibration. +The WallMote Quad is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade. + + ZW130-A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2130/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2152/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2153/xml + + https://products.z-wavealliance.org/products/2152/ + ZW130-B + Australia / New Zealand + https://products.z-wavealliance.org/products/2153/ + ZW130-C + CEPT (Europe) + + + + + false + + + + + + false + + + + + + false + + + + + + This will enable or disable the sound effects when you press or touch the sensing area + + + + + This will enable or disable the vibration effects when you press or touch the sensing area + + + + + This will enable or disable control by sliding the button area + + + + + To configure which report will be sent when pressing the buttons + + + + + + + To configure which color will be displayed when the button is pressed. + Value 1: (msb) Red. + Value 2: Green. + Value 3: Blue. + Value 4: Reserved + + + + + Get the LED Strip color value + Value 1: (msb) Red. + Value 2: Green. + Value 3: Blue. + Value 4: buzzer and vibrator. (1=ON, 0=OFF) + + + + + Set the low battery value. + Range: 10% - 50%. + + + Reset to factory defaults + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw132.xml b/openzwave/aeotec/zw132.xml new file mode 100644 index 00000000..35008e25 --- /dev/null +++ b/openzwave/aeotec/zw132.xml @@ -0,0 +1,358 @@ + + + http://www.openzwave.com/device-database/0086:0084:0103 + images/aeotec/zw132.png + https://products.z-wavealliance.org/products/2136/ + Aeotec Dual Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. +It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch. +The Dual Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade. + Dual Nano Switch + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2151/Dual Nano Switch manual.pdf + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is missing or inoperable. + ZW132-A + U.S. / Canada / Mexico + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2136/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2150/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2151/xml + + https://products.z-wavealliance.org/products/2150/ + ZW132-B + Australia / New Zealand + https://products.z-wavealliance.org/products/2151/ + ZW132-C + CEPT (Europe) + + + + + Output load will be closed after 30 seconds if the current exceeds (US: 15.5A, AU or EU: 10.5A). + + + + + Output load will be closed after 30 seconds if the temperature inside the product exceeds 100C. + + + + + Configure the output load status after re-power on + + + + + + + Enable/disable the IR sensor of WallSwipe. + (LSB) Value 1. + Value 1 = 0, disable the IR Sensor. + Value 1 = 1, enable the IR Sensor. + Value 2 = 0, Wave Option 1 is selected. + Value 2 = 1, Wave Option 2 is selected. + Value 3 = 0, disable the scene control functionality for Left/Right wave. + Value 3 = 1, enable the scene control functionality for Left/Right wave + Value 4 = 0, disable the scene control functionality for all wave actions. + Value 4 = 1, enable the scene control functionality for all wave actions. + + + + + Set the button color of WallSwipe. + Value 1= Level 1. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is UP. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Down. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Left. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Right. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when it is in Night light state. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the sensitivity of WallSwipe. + + + + To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed + + + + + + + To set which notification would be sent to the associated nodes in association group 3 when using the external switch 1 to switch the loads + + + + + To set which notification would be sent to the associated nodes in association group 4 when using the external switch 2 to switch the loads + + + + + Configure the state of LED when it is in 3 modes below + + + + + + + Value1: Hour of ON. + Value2: Minute of ON. + Value3: Hour of OFF. + Value4: Minute of OFF. + E.g. The default setting is the Night light mode is enabled at 12: 00 and disabled at 8:00 0x12000800. + + + + + Value1: 0= Disable / 1= Enable. + Value2: Weekday (Bit 0-6 means Monday to Sunday). + Value3: Hour of turning OFF. + Value4: Minute of turning OFF + E.g. The default setting 0x007F1200 + + + + + Value1: 0= Disable / 1= Enable. + Value2: Weekday (Bit 0-6 means Monday to Sunday). + Value3: Hour of turning OFF. + Value4: Minute of turning OFF + E.g. The default setting 0x001707F00 + + + + If this parameter is set to 1 (Enable), the parameter 101 - 103 should be set to 0. + + + + + The value represents the minimum change in wattage for a Report to be sent (default 25 W) + + + The value represents the minimum percentage change in wattage for a Report to be sent (Default 5) + + + Set report types for groups 1, 2 and 3 to default. + + + + Defines the type of report sent for reporting group 1. + 1 is meter report for voltage average. + 2 is meter report for current total. + 4 is meter report for watts total. + 8 is meter report for kilowatts total. + Value 1 (msb) Reserved + Value 2 + bit 4 current S2 + bit 3 current S1 + bit 2 Reserved + bit 1 voltage S2 + bit 0 voltage S1 + Value 3 + bit 4 kWh S2 + bit 3 kWh S1 + bit 2 Reserved + bit 1 watt S2 + bit 0 watt S1 + Value 4 (lsb) bits 7-4 reserved + bit 3 current total + bit 2 voltage average + bit 1 watt total + bit 0 kWh total + + + + + Defines the type of report sent for reporting group 2. + 1 is meter report for voltage average. + 2 is meter report for current total. + 4 is meter report for watts total. + 8 is meter report for kilowatts total. + Value 1 (msb) Reserved + Value 2 + bit 4 current S2 + bit 3 current S1 + bit 2 Reserved + bit 1 voltage S2 + bit 0 voltage S1 + Value 3 + bit 4 kWh S2 + bit 3 kWh S1 + bit 2 Reserved + bit 1 watt S2 + bit 0 watt S1 + Value 4 (lsb) bits 7-4 reserved + bit 3 current total + bit 2 voltage average + bit 1 watt total + bit 0 kWh total + + + + + Defines the type of report sent for reporting group 3. + 1 is meter report for voltage average. + 2 is meter report for current total. + 4 is meter report for watts total. + 8 is meter report for kilowatts total. + Value 1 (msb) Reserved + Value 2 + bit 4 current S2 + bit 3 current S1 + bit 2 Reserved + bit 1 voltage S2 + bit 0 voltage S1 + Value 3 + bit 4 kWh S2 + bit 3 kWh S1 + bit 2 Reserved + bit 1 watt S2 + bit 0 watt S1 + Value 4 (lsb) bits 7-4 reserved + bit 3 current total + bit 2 voltage average + bit 1 watt total + bit 0 kWh total + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + Defines the time interval when the defined report for group 1 is sent. + + + Defines the time interval when the defined report for group 2 is sent. + + + Defines the time interval when the defined report for group 3 is sent. + + + When the switch mode of S1 is determined or identified or configured, this mode value will not be reset after exclusion + + + + + + + + When the switch mode of S2 is determined or identified or configured, this mode value will not be reset after exclusion + + + + + + + + Set the control destination for external switch S1 + + + + + + Set the control destination for external switch S2 + + + + + + Get the state of touch panel port + + + + + Set the working way for S1/S2 when the Switch mode is 3-way switch mode. + + + + + + + + Set the function of S1/S2. + Bit 0 = 0, the function of sending NIF is disabled. + Bit 0 = 1, the function of sending NIF is enabled. + Bit 1 = 0, the function of entering RF power level test mode is disabled. + Bit 1 = 1, the function of entering RF power level test mode is enabled. + Bit 2 = 0, the function of factory reset is disabled. + Bit 2 = 1, the function of factory reset is enabled. + Bit 3 to Bit 6 are reserved. + Bit 7 = 0, the setting for Bit 0 to Bit 2 are ineffective. Bit 7 = 1, the setting for Bit 0 to Bit 2 are effective. + + + + Enable/disable the factory reset function of Action Button, external switches or WallSwipe. + + + + + Enable/disable Configuration Locked + + + + + Reset to factory defaults + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw139.xml b/openzwave/aeotec/zw139.xml new file mode 100644 index 00000000..5432a51b --- /dev/null +++ b/openzwave/aeotec/zw139.xml @@ -0,0 +1,235 @@ + + + http://www.openzwave.com/device-database/0086:008B:0103 + images/aeotec/zw139.png + https://products.z-wavealliance.org/products/2306/ + Nano Switch + Aeotec Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. +It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch. +The Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade. + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2320/Nano Switch manual.pdf + ZW139-A + U.S. / Canada / Mexico + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2306/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2319/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2320/xml + + https://products.z-wavealliance.org/products/2319/ + ZW139-B + Australia / New Zealand + https://products.z-wavealliance.org/products/2320/ + ZW139-C + CEPT (Europe) + + + + + Output load will be closed after 30 seconds if the temperature inside the product exceeds 100C. + + + + + Configure the output load status after re-power on + + + + + + + Enable/disable the IR sensor of WallSwipe. + (LSB) Value 1. + Value 1 = 0, disable the IR Sensor. + Value 1 = 1, enable the IR Sensor. + Value 2 = 0, Wave Option 1 is selected. + Value 2 = 1, Wave Option 2 is selected. + Value 3 = 0, disable the scene control functionality for Left/Right wave. + Value 3 = 1, enable the scene control functionality for Left/Right wave + Value 4 = 0, disable the scene control functionality for all wave actions. + Value 4 = 1, enable the scene control functionality for all wave actions. + + + + + Set the button color of WallSwipe. + Value 1= Level 1. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is UP. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Down. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Left. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Right. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when it is in Night light state. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the sensitivity of WallSwipe. + + + + To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed + + + + + + + To set which notification would be sent to the associated nodes in association group 3 when using the external switch 1 to switch the loads + + + + + To set which notification would be sent to the associated nodes in association group 4 when using the external switch 2 to switch the loads + + + + + Configure the state of LED when it is in 3 modes below + + + + + + + Value1: Hour of ON. + Value2: Minute of ON. + Value3: Hour of OFF. + Value4: Minute of OFF. + E.g. The default setting is the Night light mode is enabled at 12: 00 and disabled at 8:00 0x12000800. + + + + + Value1: 0= Disable / 1= Enable. + Value2: Weekday (Bit 0-6 means Monday to Sunday). + Value3: Hour of turning OFF. + Value4: Minute of turning OFF + E.g. The default setting 0x007F1200 + + + + + Value1: 0= Disable / 1= Enable. + Value2: Weekday (Bit 0-6 means Monday to Sunday). + Value3: Hour of turning OFF. + Value4: Minute of turning OFF + E.g. The default setting 0x001707F00 + + + + When the switch mode of S1 is determined or identified or configured, this mode value will not be reset after exclusion + + + + + + + + When the switch mode of S2 is determined or identified or configured, this mode value will not be reset after exclusion + + + + + + + + + + + + + + Get the state of touch panel port + + + + + Set the working way for S1/S2 when the Switch mode is 3-way switch mode. + + + + + + + + Set the function of S1/S2. + Bit 0 = 0, the function of sending NIF is disabled. + Bit 0 = 1, the function of sending NIF is enabled. + Bit 1 = 0, the function of entering RF power level test mode is disabled. + Bit 1 = 1, the function of entering RF power level test mode is enabled. + Bit 2 = 0, the function of factory reset is disabled. + Bit 2 = 1, the function of factory reset is enabled. + Bit 3 to Bit 6 are reserved. + Bit 7 = 0, the setting for Bit 0 to Bit 2 are ineffective. Bit 7 = 1, the setting for Bit 0 to Bit 2 are effective. + + + + Enable/disable the factory reset function of Action Button, external switches or WallSwipe. + + + + + Reset to factory defaults + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw140.xml b/openzwave/aeotec/zw140.xml new file mode 100644 index 00000000..ec03c4c0 --- /dev/null +++ b/openzwave/aeotec/zw140.xml @@ -0,0 +1,250 @@ + + + http://www.openzwave.com/device-database/0086:008C:0103 + images/aeotec/zw140.png + https://products.z-wavealliance.org/products/2247/ + Dual Nano Switch + Aeotec Dual Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. +In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. +It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch. +The Dual Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade. + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2313/Dual Nano Switch manual.pdf + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + U.S. / Canada / Mexico + ZW140-A + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2247/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2312/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2313/xml + + https://products.z-wavealliance.org/products/2312/ + Australia / New Zealand + ZW140-B + https://products.z-wavealliance.org/products/2313/ + CEPT (Europe) + ZW140-C + + + + + Output load will be closed after 30 seconds if the temperature inside the product exceeds 100C. + + + + + Configure the output load status after re-power on + + + + + + + Enable/disable the IR sensor of WallSwipe. + (LSB) Value 1. + Value 1 = 0, disable the IR Sensor. + Value 1 = 1, enable the IR Sensor. + Value 2 = 0, Wave Option 1 is selected. + Value 2 = 1, Wave Option 2 is selected. + Value 3 = 0, disable the scene control functionality for Left/Right wave. + Value 3 = 1, enable the scene control functionality for Left/Right wave + Value 4 = 0, disable the scene control functionality for all wave actions. + Value 4 = 1, enable the scene control functionality for all wave actions. + + + + + Set the button color of WallSwipe. + Value 1= Level 1. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is UP. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Down. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Left. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when the gesture action is Right. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the LED indication color of WallSwipe when it is in Night light state. + Value 1= Reserved. + Value 2= the color value of Red. + Value 3= the color value of Green. + Value 4= the color value of Blue. + + + + + Set the sensitivity of WallSwipe. + + + + + To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed. + Note: When just only one channel load state is changed, the report message Hail CC or Basic Report CC would be Multi Channel encapsulated. + + + + + + + + To set which notification would be sent to the associated nodes in association group 3 when using the external switch 1 to switch the loads + + + + + To set which notification would be sent to the associated nodes in association group 4 when using the external switch 2 to switch the loads + + + + + Configure the state of LED when it is in 3 modes below + + + + + + + Value1: Hour of ON. + Value2: Minute of ON. + Value3: Hour of OFF. + Value4: Minute of OFF. + E.g. The default setting is the Night light mode is enabled at 12: 00 and disabled at 8:00 0x12000800. + + + + + Value1: 0= Disable / 1= Enable. + Value2: Weekday (Bit 0-6 means Monday to Sunday). + Value3: Hour of turning OFF. + Value4: Minute of turning OFF + E.g. The default setting 0x007F1200 + + + + + Value1: 0= Disable / 1= Enable. + Value2: Weekday (Bit 0-6 means Monday to Sunday). + Value3: Hour of turning OFF. + Value4: Minute of turning OFF + E.g. The default setting 0x001707F00 + + + + When the switch mode of S1 is determined or identified or configured, this mode value will not be reset after exclusion + + + + + + + + When the switch mode of S2 is determined or identified or configured, this mode value will not be reset after exclusion + + + + + + + + Set the control destination for external switch S1 + + + + + + Set the control destination for external switch S2 + + + + + + Get the state of touch panel port + + + + + Set the working way for S1/S2 when the Switch mode is 3-way switch mode. + + + + + + + + Set the function of S1/S2. + Bit 0 = 0, the function of sending NIF is disabled. + Bit 0 = 1, the function of sending NIF is enabled. + Bit 1 = 0, the function of entering RF power level test mode is disabled. + Bit 1 = 1, the function of entering RF power level test mode is enabled. + Bit 2 = 0, the function of factory reset is disabled. + Bit 2 = 1, the function of factory reset is enabled. + Bit 3 to Bit 6 are reserved. + Bit 7 = 0, the setting for Bit 0 to Bit 2 are ineffective. Bit 7 = 1, the setting for Bit 0 to Bit 2 are effective. + + + + Enable/disable the factory reset function of Action Button, external switches or WallSwipe. + + + + + Enable/disable Configuration Locked + + + + + Reset to factory defaults + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw141.xml b/openzwave/aeotec/zw141.xml new file mode 100644 index 00000000..96975947 --- /dev/null +++ b/openzwave/aeotec/zw141.xml @@ -0,0 +1,175 @@ + + + + http://www.openzwave.com/device-database/0086:008D:0103 + images/aeotec/zw141.png + https://products.z-wavealliance.org/products/3693 + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3693/Nano%20Shutter%20-%20Product%20Manual.pdf + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + Turn the primary controller of Z-Wave network into exclusion mode, quick press the product’s Action button 6 times that you can find on the product's housing or toggle the external manual switch 2 times in fast succession. If the Nano Dimmer has been successfully removed from your Z-Wave network, its RGB LED will remain colorful gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load), repeat the instructions above from step 1. + Nano Shutter + Aeotec New Generation Nano Shutter 1. Used to control the motor of Curtain, support Shutter Mode and Venetian Mode . 2. Can be calibrated according to diff e rent curtains 3. Used to control other Z-Wave device directly. 4. Support S2, more safe and more re liable 5. Support SmartStart, faster inclusion + ZW141-C + CEPT (Europe) + https://products.z-wavealliance.org/Products/3693 + + 1. Set your z-wave controller into 'Add Device' mode to add the product into your z-wave network. Refer to the controller's manual if you are unsure of how to perform this step. + 2. Make sure the product is powered on. If not, plug it into a wall socket and power on; the LED will flash a blinking blue light. + 3. Click the action button once, the LED should flash a blue light for 30 seconds until the product is added into the network. The LED will flash a bright yellow light after being assigned a NodeID. + 4. If your z-wave controller supports S2 encryption, enter the first 5 digits of the DSK into your controller's interface if/when requested. The DSK is printed on its housing. + 5. If inclusion fails, the LED will flash a bright red light for 2 second and then flash a blinking blue light; repeat steps 1 to 4. Contact us for further support if needed. + 6. If inclusion succeeds, the LED will flash a bright blue light for 2 second and then turn to load indicator mode to indicate the product has been added to your z-wave network successfully. You can configure the product and its automations via your smart home automation platform; please refer to your software's user guide for details. + + + 1. Set your z-wave controller into 'Remove Device' mode to remove the product from your z-wave network. Refer to the controller's manual if you are unsure of how to perform this step. + 2. Click the action / S1 / S2 button 6 times to enter exclusion mode. + 3. If removal fails, the LED will flash bright red for 2 seconds and then turn return to regular light mode; repeat steps 1-2. Contact us for further support if needed. + 4. If removal succeeds, the LED will flash a blinking blue light to indicate the product has been removed from the z-wave network successfully. + + + Press and hold the action button for at least 20 second and then release. The LED will blink a blue light to indicate the factory reset was successful. Otherwise, please try again. Contact us for further support if needed. + This procedure should only be used when the primary controller is missing or inoperable. + Factory reset will: a) remove the product from your z-wave network; and b) delete the association setting. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2903/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2907/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2953/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3075/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/3693/XML + Fixed timing types, Fixed button list types + + U.S. / Canada / Mexico + ZW141-A + ZW141-B + Australia / New Zealand + + + + + Set the motor behavior after powering on + + + + + + Set to toggle the motor running direction + + + Set the blade turn time for Venetian mode. Details can be found in section 4.2 of Advanced information Product Manual. + + + Set the run time of the curtain. Details can be found in section 4.2 of Advanced information Product Manual. + + + Set to enter/exit calibration mode + + + + + + Set user confirmation for calibration + + + + + Get calibration mode status report + + + + + + + + + Set the curtain mode operation + + + + + Set to begin repositioning + + + + + Get repositioning status report + + + + + Enable/disable calibration lock + + + + + Set S1 scene activation + + + + + + + Set S1 scene activation + + + + + + + Select which report to send when switch status changes + + + + + + + Set operation mode of external button. + In Operation Mode 1, external button 1 maps to z-wave button, external button 2 opens or stops motor. + In Operation Mode 2, external button 1 maps to z-wave button, external button 2 closes or stops motor. + + + + + + When the mode is determined, this mode value will not be reset after exclusion + + + + + + + + When the mode is determined, this mode value will not be reset after exclusion + + + + + + + + Get the DSK from the product + + + Set the operation of external switches S1 and S2 + + + + + + Reset to factory defaults + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw162.xml b/openzwave/aeotec/zw162.xml new file mode 100644 index 00000000..5a1e7eae --- /dev/null +++ b/openzwave/aeotec/zw162.xml @@ -0,0 +1,330 @@ + + + http://www.openzwave.com/device-database/0371:00A2:0103 + images/aeotec/zw162.png + https://products.z-wavealliance.org/products/3218/ + This product supports Security 2 Command Class. While a Security S2 enabled Controller is needed in order to fully use the security feature. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will +act as repeaters regardless of vendor to increase reliability of the network. + +1. Set your Z-Wave Controller into its 'Add Device' mode in order to add Chime into your Z-Wave system. Refer to the Controller's manual if you are unsure of how to perform this step. + +2. Power on Chime via the provided power adapter; its LED will be breathing white light all the time. + +3. Click Chime Action Button once, it will quickly flash white light for 30 seconds until Chime is added into the network. It will become constantly bright white light after being assigned a NodeID. + +4. If your Z-Wave Controller supports S2 encryption, enter the first 5 digits of DSK into your Controller's interface if/when requested. The DSK is printed on Chime's housing. + +5. If Adding fails, it will slowly flash white light 3 times and then become breathing white light; repeat steps 1 to 4. Contact us for further support if needed. + +6. If Adding succeeds, it will quickly flash white light 3 times and then become off. Now, Chime is a part of your Z-Wave home control system. You can configure it and its automations via your Z-Wave system; please refer to your software's user guide for precise instructions. + +Note: +If Action Button is clicked again during the Learn Mode, the Learn Mode will exit. At the same time, Indicator Light will extinguish immediately, and then become breathing white light. + U.S. / Canada / Mexico + Doorbell 6 + - S2 Security. +- Not only a doorbell, but also can be used as a siren via setting. +- Can be wireless controlled by more Button, up to 3. +- Longer Button control distance, up to 120m. +- Built-in multiple tones, up to 30. +- Built-in multiple adjustable Light Effect. + + 1. Set your Z-Wave Controller into its ' Remove Device' mode in order to remove Chime from your Z-Wave system. Refer to the Controller's manual if you are unsure of how to perform this step. + +2. Power on Chime via the provided power adapter; its LED will be off. + +3. Click Chime Action Button 6 times quickly; it will bright white light, up to 2s. + +4. If Removing fails, it will keep off; repeat steps 1 to 3. Contact us for further support if needed. + +5. If Removing succeeds, it will quickly flash white light 3 times and then become breathing white light. Now, Chime is removed from Z-Wave network successfully. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3292/Doorbell 6 product manual.pdf + If the primary controller is missing or inoperable, you may need to reset the device to factory settings. + +Make sure the Chime is powered. To complete the reset process manually, press and hold the Action Button for at least 20s. The LED indicator will quickly flash white light 3 times and then become breathing white light, which indicates the reset operation is successful. Otherwise, please try again. Contact us for further support if needed. + +Note: +1. This procedure should only be used when the primary controller is missing or inoperable. +2. Factory Reset Chime will: +(a) Remove Chime from Z-Wave network; +(b) Delete the Association setting; +(c) Restore the configuration settings to the default.(Except configuration parameter 51/52/53/54) + ZW162-A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3218/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3291/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3292/xml + Fix up MapRootToEndpoint and Basic Get Disabled + Add option 96, allow stopping playing chime + + https://products.z-wavealliance.org/products/3291/ + Australia / New Zealand + ZW162-B + https://products.z-wavealliance.org/products/3292/ + ZW162-C + CEPT (Europe) + + + + + + Light Effect and PlayTone configuration for Browse Endping + + + + Use the Last Valid Configuration Value for the Light Effect + + + + Use Light Effect #7, Defined in Parameter 22 + + + + Use Light Effect #6, Defined in Parameter 21 + + + + Use Light Effect #5, Defined in Parameter 20 + + + + Use Light Effect #4, Defined in Parameter 19 + + + + Use Light Effect #3, Defined in Parameter 18 + + + + Use Light Effect #2, Defined in Parameter 17 + + + + Use Light Effect #1, Defined in Parameter 16 + + + + Use the Last Valid Configuration Value for the Tone + + + + If you’re not sure which tone to use, you can configure the value of Tone Play Mode to be 3. Then send Basic Set 0xFF to Endpoint 1 or Root Device to trigger auto-selecting tone function. Chime will play built-in tones randomly and the Default Tone Identifier will be changed each time a new tone is played. When send Basic Set 0x00 to Endpoint 1 or Root Device to stop playing tone, the Default Tone Identifier will store, which means the tone has been selected. +Please note that the Tone Play Mode needs to be configured to be 0 or 1 after the tone is selected, otherwise the automatic selection tone function will be retriggered when the Endpoint 1 or Root Device is triggered to play tone and light again. + + + + If you’re not sure which tone to use, you can configure the value of Tone Play Mode to be 2. Then send Basic Set 0xFF to Endpoint 1 or Root Device to trigger auto-selecting tone function. Chime will play built-in tones in order and the Default Tone Identifier will be changed each time a new tone is played. When send Basic Set 0x00 to Endpoint 1 or Root Device to stop playing tone, the Default Tone Identifier will store, which means the tone has been selected. +Please note that the Tone Play Mode needs to be configured to be 0 or 1 after the tone is selected, otherwise the automatic selection tone function will be retriggered when the Endpoint 1 or Root Device is triggered to play tone and light again. + + + + Use a single loop playback for the Tone + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Configure how to send Basic Set to nodes in Group 2 + + + + + + + + Configure how to send Basic Set to nodes in Group 3 + + + + + + + + Configure how to send Basic Set to nodes in Group 4 + + + + + + + + Configure how to send Basic Set to nodes in Group 5 + + + + + + + + Configure how to send Basic Set to nodes in Group 6 + + + + + + + + Configure how to send Basic Set to nodes in Group 8 + + + + + + + + Configure how to send Basic Set to nodes in Group 9 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Please Refer to Engineering Specification - Aeotec Doorbell 6 + + + + Enable or Disable the ability that click the Action Button to stop a playing tone. + + + Reset to factory defaults + + + + + + + + false + + + + + true + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw164.xml b/openzwave/aeotec/zw164.xml new file mode 100644 index 00000000..0ac6c651 --- /dev/null +++ b/openzwave/aeotec/zw164.xml @@ -0,0 +1,315 @@ + + + + + http://www.openzwave.com/device-database/0086:00a4:0003 + images/aeotec/zw164.png + ZW164-C + https://products.z-wavealliance.org/products/3301/ + CEPT (Europe) + ZW164-A + https://products.z-wavealliance.org/products/3284/ + U.S. / Canada / Mexico + + This product supports Security 2 Command Class. While a Security S2 enabled Controller is needed in order to fully use the security feature. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. 1. Set your Z-Wave Controller into its 'Add Device' mode in order to add Chime into your Z-Wave system. Refer to the Controller's manual if you are unsure of how to perform this step. 2. Power on Chime via the provided power adapter; its LED will be breathing white light all the time. 3. Click Chime Action Button once, it will quickly flash white light for 30 seconds until Chime is added into the network. It will become constantly bright white light after being assigned a NodeID. 4. If your Z-Wave Controller supports S2 encryption, enter the first 5 digits of DSK into your Controller's interface if/when requested. The DSK is printed on Chime's housing. 5. If Adding fails, it will slowly flash white light 3 times and then become breathing white light; repeat steps 1 to 4. Contact us for further support if needed. 6. If Adding succeeds, it will quickly flash white light 3 times and then become off. Now, Chime is a part of your Z-Wave home control system. You can configure it and its automations via your Z-Wave system; please refer to your software's user guide for precise instructions. Note: If Action Button is clicked again during the Learn Mode, the Learn Mode will exit. At the same time, Indicator Light will extinguish immediately, and then become breathing white light. + Indoor Siren 6 + 1. Set your Z-Wave Controller into its ' Remove Device' mode in order to remove Chime from your Z-Wave system. Refer to the Controller's manual if you are unsure of how to perform this step. 2. Power on Chime via the provided power adapter; its LED will be off. 3. Click Chime Action Button 6 times quickly; it will bright white light, up to 2s. 4. If Removing fails, it will keep off; repeat steps 1 to 3. Contact us for further support if needed. 5. If Removing succeeds, it will quickly flash white light 3 times and then become breathing white light. Now, Chime is removed from Z-Wave network successfully. + - S2 Security. - Not only a siren, but also can be used as a doorbell via setting. - Can be wireless controlled by more Button, up to 3. - Longer Button control distance, up to 120m. - Built-in multiple tones, up to 30. - Built-in multiple adjustable Light Effect. + If the primary controller is missing or inoperable, you may need to reset the device to factory settings. Make sure the Chime is powered. To complete the reset process manually, press and hold the Action Button for at least 20s. The LED indicator will quickly flash white light 3 times and then become breathing white light, which indicates the reset operation is successful. Otherwise, please try again. Contact us for further support if needed. Note: 1. This procedure should only be used when the primary controller is missing or inoperable. 2. Factory Reset Chime will: (a) Remove Chime from Z-Wave network; (b) Delete the Association setting; (c) Restore the configuration settings to the default.(Except configuration parameter 51/52/53/54) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3301/Indoor%20Siren%206%20product%20manual.pdf + + Add metadata for aeotec indoor siren 6 #1894 + Add metadata for North American model - https://products.z-wavealliance.org/products/3284 + + + + + + + true + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Please Refer to Engineering Specification - Aeotec Indoor Siren 6 + + + + + Please Refer to Engineering Specification - Aeotec Indoor Siren 6 + + + + + Please Refer to Engineering Specification - Aeotec Indoor Siren 6 + + + + + + + + + + Reset to factory defaults + + + + + + + + + + false + + + + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw175.xml b/openzwave/aeotec/zw175.xml new file mode 100644 index 00000000..a4d47b55 --- /dev/null +++ b/openzwave/aeotec/zw175.xml @@ -0,0 +1,183 @@ + + + ZW175 Smart Switch 7 + + Elegant appearance, small size, easy to use, friendly operation. + Support power metering function, with high measurement accuracy, and more accurate knowledge of the power consumption of the load. + Support over-current, over-load and over-heat protection, which is more secure and reliable. + Support scene personalization and is more intelligent. + Support Night Light Mode to reduce light pollution. + Support S2 Security, which is safer and more reliable. + Support SmartStart, making inclusion more convenient. + + http://www.openzwave.com/device-database/0371:00af:0003 + https://products.z-wavealliance.org/products/3437 + https://products.z-wavealliance.org/products/3437 + images/aeotec/zw195.png + https://products.z-wavealliance.org/products/3437 + N/A + + 1. Set your Z-Wave Controller into its 'Add Device' mode in order to add the product into your Z-Wave system. Refer to the Controller's manual if you are unsure of how to perform this step. + 2. Make sure the product is powered. If not, plug it into a wall socket and power on; its LED will be breathing blue light all the time. + 3. Click Action Button once, it will quickly flash blue light for 30 seconds until it is added into the network. It will become constantly bright yellow light after being assigned a NodeID. + 4. If your Z-Wave Controller supports S2 encryption, enter the first 5 digits of DSK into your Controller's interface if /when requested. The DSK is printed on its housing. + 5. If Adding fails, it will bright red light for 2s and then become breathing blue light; repeat steps 1 to 4. Contact us for further support if needed. + 6. If Adding succeeds, it will bright blue light for 2s and then turn to Load Indicator Mode. Now, this product is a part of your Z-Wave home control system. You can configure it and its automations via your Z-Wave system; please refer to your software's user guide for precise instructions. + + 1. Set your Z-Wave Controller into its 'Remove Device' mode in order to remove the product from your Z-Wave system. Refer to the Controller's manual if you are unsure of how to perform this step. + 2. Make sure the product is powered. If not, plug it into a wall socket and power on. 3. Click Action Button 2 times quickly; it will bright violet light, up to 2s. + 4. If Removing fails, it will bright red light for 2s and then turn back to Load Indicator Mode; repeat steps 1 to 3. Contact us for further support if needed. + 5. If Removing succeeds, it will become breathing blue light. Now, it is removed from Z-Wave network successfully. + + Make sure the product is powered. If not, plug it into a wall socket and power on. To complete the reset process manually, press and hold the Action Button for at least 15s and then release. The LED indicator will become breathing blue light, which indicates the reset operation is successful. Otherwise, please try again. + https://products.z-wavealliance.org/products/3437 + CEPT (Europe) + ZW175-C16 + + Add ZW175 Smart Switch 7 + Change refresh on node info frame + Fix description on configuration parameters 101 and 111 (power reporting) + + + + + + + + + Define a threshold power and automatically turn off switch when the load connected bypasses the maximum allowed power regardless of always on setting. + Note: + Over-load protection will be active if the load power exceeds the setting and lasts for more than 30s. + If be active, Indicator Light will become red light blinking and the product will send out Notification Report (Over-load detected), and disable the function that manually or RF control the switch state until users set Protection State to be unprotected through the Gateway or Controller. + Even power off will still keep Protection State. + + + + + Enabled by (Alarm Settings), and determines what the switch does in the case an alarm is triggered. + Note: + When receives any alarm enabled by Alarm Settings, Indicator Light will keep blinking based on Parameter 18. + It will prohibit user from manually or RF control the switch state until the alarm is disable. + + + + + + + + + Determine if alarms are enabled in Switch, and what Switch will react to which alarm. + The format of the parameter is Bit field (Checkboxes). + The parameter MUST be treated as a bit field where each individual bit can be set or reset. + A graphical configuration tool SHOULD present this parameter as a series of checkboxes. + + + + + Determines the method of disabling the alarm of the device. + Note: Power off will also disable the alarm response without any limitation. + + 0=> Can be disabled by 3x tapping Action Button within 1 second. + 1=> Can be disabled when receives a State Idle corresponding to the alarm. + Note: If Access Control is enable, it also can be disabled when receives the reversal state of window/door. + 10..255=> Sets the duration of the alarm in seconds(i.e. Customer sets this setting to 50, the alarm state of the Switch will disable after 50 seconds) + + + + + Set amount of blinks per seconds. + Note: When receiving the enable Alarm, it will flash according to the blink frequency configured by this parameter until the Alarm is disable. + Brightness level and color is based on current indicator. + If the value of brightness level and color is 0, it will flash based on last visible color. + + + + + Note: The parameter can be used to test the effect of LED blinking. + 0=> Stop blinking. + 1..255=> Set the duration and start the blinking process. + * This sets the timeframe of blinking in seconds. + * Once the duration ends, the blinking will stop. + + + + Configure the output load status after re-power on. + + + + + + Defines the automated status notification of an associated device when status changes + + + + + + Configuring brightness and color of Indicator Light in different time/status of different modes will be saved in the current setting mode. + + + + + + + Value1: Enable Hour. Valid value are 0-23 and 127. Value 127 means use last valid setting. + Value2: Enable Minute. Valid value are 0-59 and 255. Value 255 means use last valid setting. + Value3: Disable Hour. Valid value are 0-23 and 255. Value 255 means use last valid setting. + Value4: Disable Minute. Valid value are 0-59 and 255. Value 255 means use last valid setting. + + + + + 0 => Disable. + 1-2300 => 1-2300W. + + + + + 0 => Disable. + 1-10000 => 1-10000kWh. + + + + + 0 => Disable. + 1-100 => 0.1-10A. + + + + + Defines the type of report sent for reporting group 1. + 1 is meter report for kilowatts. + 2 is meter report for watts. + 4 is meter report for voltage. + 8 is meter report for current. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 Current + bit 2 Voltage + bit 1 Power + bit 0 Power Consumption + + + + + 0 => Disable. + 30..2592000 => 30-2592000s. (30seconds-30day) + + + + Reset to factory defaults + + + + + + + + + + + + diff --git a/openzwave/aeotec/zw187.xml b/openzwave/aeotec/zw187.xml new file mode 100644 index 00000000..75d7e9ae --- /dev/null +++ b/openzwave/aeotec/zw187.xml @@ -0,0 +1,97 @@ + + + + http://www.openzwave.com/device-database/0371:00bb:0002 + images/aeotec/zw187.png + https://products.z-wavealliance.org/products/3694/ + CEPT (Europe) + ZW089-C + https://products.z-wavealliance.org/products/3694/ + U.S. / Canada / Mexico + ZW089-A + https://products.z-wavealliance.org/products/3694/ + Australia / New Zealand + ZW089-B + Recessed Door Sensor 7 + Press and hold the Z-Wave button for 5 seconds will trigger sending the Wake up notification command and then keep waking up for 10 seconds after release the Z-Wave button. + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3694/Recessed%20Door%20Sensor%207%20-%20Product%20Manual.pdf + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Z-Wave button that you can find in the back of the product. + Press and hold the Z-Wave button that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Z-Wave button that you can find in back of the product. + The Aeotec Recessed Door Sensor 7 is a door sensor that can detect the state of the door's open/close. It will report the door state to your controller/ gateway/associated nodes in real time when the state of your door has a change. +It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs. +It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications. + + + Initial version + Notification Class is supported by device + + + + + + Enable/Disable Binary Sensor Report. Allow for backward compatibility to report Binary if Notification Report cannot be used for status changes. + + + + + Reverse Sensor Reports (both Sensor Binary Report and Notification Report.) + + + + + Configure the Basic Set value. Determine the Basic Set value to control other Z-Wave devices directly when Magnet is away or near. + + + + + + + + + + + Configure retry number and wait time. + The device supports an application retry mechanism when the application of the device has detected a transmission error when Basic Set, Sensor Binary Report or Notification Report (Access Control) message is sent out but fails to result in an ACK or a Supervision Report. + The Byte 1 is used to configure the number of retries. The valid value is 0-5. 0 means disable retry. + The Byte 2 is used to configure the wait time between retries. The valid value is 0-255. Unit is 100ms. + + + + + Configure Supervision Report Wait Time. + Unit is 100ms. + Note: Issuing Basic Set, Sensor Binary Report or Notification Report(Access Control) via association groups uses Supervision encapsulation only if sending commands with S2(or higher security) encapsulation. + In other word, this parameter can be configured in any network, but works only in S2 (or higher security) network. + + + + + Control LED Indicator. Determine whether the LED flash or not when sending Basic Set, Sensor Binary Report, Notification Report (Access Control) or Wake Up Notification. + + + + + + + + Configure the low battery threshold. Induce battery report when battery level is less than or equal to threshold. Forward low battery report. + + + Set how often battery is reported in minutes. + + + + + + true + + + + + + + + + + diff --git a/openzwave/aeotec/zw189.xml b/openzwave/aeotec/zw189.xml new file mode 100644 index 00000000..3a8bd1a0 --- /dev/null +++ b/openzwave/aeotec/zw189.xml @@ -0,0 +1,39 @@ + + + + http://www.openzwave.com/device-database/0371:00bd:0004 + images/aeotec/zw189.png + https://products.z-wavealliance.org/products/3616 + CEPT (Europe) + ZW189-C + https://products.z-wavealliance.org/products/3616 + U.S. / Canada / Mexico + ZW189-A + Turn the primary controller of Z-Wave network into exclusion mode, press the Z-Wave Button on Range Extender 7. + Aeotec Range Extender 7 is a Z-Wave mesh network repeater which can extend the range of communication between Z-Wave products and assist other devices to reach each other in your Z-Wave network. + The Range Extender can also communicate securely via AES 128 wireless Z-Wave commands and supports Over-The-Air (OTA) firmware upgrades. + + Range Extender 7 + Press and hold the Z-Wave Button for 20 seconds and then release it. + Use this procedure only in the event that your primary network controller is missing or inoperable. + + Turn the primary controller of Z-Wave network into inclusion mode, press the Z-Wave Button on Range Extender 7. + + Initial version + + + + + + false + + + + + + + + + diff --git a/openzwave/aeotec/zwa001.xml b/openzwave/aeotec/zwa001.xml new file mode 100644 index 00000000..8547f84c --- /dev/null +++ b/openzwave/aeotec/zwa001.xml @@ -0,0 +1,66 @@ + + + http://www.openzwave.com/device-database/0371:0001:0003 + images/aeotec/zwa001.png + https://products.z-wavealliance.org/products/2840/ + LED Bulb 6: Multi-White + Reset the device : +a) Please use this procedure only when the network primary controller is missing or otherwise inoperable. +b) Led bulb re-power 6 times (between 0.5-2 seconds each time); If the 6th power on, the led bulb flashes twice, which means that the resetting is successful. + + + Standard form factor and appearance of the light bulb with 800 lm output +Tunable white: dimmable from 5% to 100%, tunable from 2700K to 6500K. +Possible to be included in groups, scenes, or schedules +Suitable for indoor lighting: Corridors, Bedroom, Living Room, etc. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2843/LED Bulb Manul.pdf + + ZWA001-C + Remove for exclusion: +a) Set the Z-Wave network main controller into removing mode. +b) Led bulb re-power 3 times (between 0.5-2 seconds each time). +c) Wait a moment, the led bulb should be removed from the controller.Then the led bulb will flash once, dim to 5% first, and then increased to 100% after 5 seconds. + + Add for inclusion: +a) Set the Z-Wave network main controller into adding mode. +b) Power cycle once for led bulb(OFF->ON).The led bulb will flash twice and send node info frame. +c) Wait a moment, the led bulb should be added to the controller.Then the led bulb will flash once when it has been included into the network. + + + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2840/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2843/xml + + https://products.z-wavealliance.org/products/2843/ + U.S. / Canada / Mexico + ZWA001-A + + + + + Enable to send notifications to associated devices (Group 1) when the state of LED Bulb is changed. + + + + + + Adjusting the color temperature in warm white color component. + available value: 2700k to 4999k + + + + Adjusting the color temperature in cold white color component. + available value:5000k to 6500k + + + + + + + + + + diff --git a/openzwave/aeotec/zwa002.xml b/openzwave/aeotec/zwa002.xml new file mode 100644 index 00000000..9a0781e8 --- /dev/null +++ b/openzwave/aeotec/zwa002.xml @@ -0,0 +1,109 @@ + + + http://www.openzwave.com/device-database/0371:0002:0103 + images/aeotec/zwa002.png + https://products.z-wavealliance.org/products/2880/ + U.S. / Canada / Mexico + Reset the Device. +1. Assuming led bulb was added to controller and was power on. +2. RGBW bulb re-power 6 times (between 0.5-2 seconds each time). +Note: ON -> OFF -> ON -> OFF -> ON -> OFF -> ON -> OFF -> ON -> OFF -> ON -> OFF -> ON +3. If the 6th power on, the led bulb change to Yellow color(into pairing process ), which means that the reset factory settings are successf. + +Using this action in case of the primary controller is missing or inoperable. + + ✓ Standard form factor and appearance of the light bulb with 800 lm output +✓ RGBW: dimmable from 5% to 100%, tunable from 1800K to 6500K, and 16 million colors +✓ Possible to be included in groups, scenes, or schedules +✓ Suitable for indoor lighting: Corridors, Bedroom, Living Room, etc. + Add for inclusion +1. Ensure the led bulb has been excluded outside the network. +2. Triggered by OFF ->ON (between 0.5-2 seconds each time) +3. LED solid yellow Color (0xFFFF00) during the pairing(Timeout is 10 seconds). + + Failure: +Blinks between 100% White and Red 0x0000FF color for 3 seconds (at a rate of 200ms per flash), Once 3 seconds have passed, the LED should return to a Warm White LED at 100% + Success: +Blinks between 100% White and Green 0x00FF00 color for 3 seconds (at a rate of 200ms per flash). Once 3 seconds have passed, the LED should return to a Warm White LED at 100%. + + LED Bulb 6:Multi-Colour + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2881/AA LED Bulb 6 说明书(RGBW-AL001)_转曲-2dd.pdf + Remove for exclusion +1. Assuming led bulb was added to controller. +2. Triggered by OFF -> ON -> OFF -> ON -> OFF -> ON (between 0.5-2 seconds each time). +3. LED Solid Purple/Violet Color (0xEE82EE) during the unpairing process. (Timeout is 10 seconds). + Failure: +Blinks between 100% White and Red 0x0000FF color for 3 seconds (at a rate of 200ms per flash), Once 3 seconds have passed, the LED should return to the last color ( memory status(color cc set)) of LED Bulb. + Success: +Blinks between 100% White and Blue 0x0000FF color for 3 seconds (at a rate of 200ms per flash). Once 3 seconds have passed, the LED should return to a Warm White LED at 100%. + + ZWA002-A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2880/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2881/xml + Add Verified Change Flag to Color CC + + https://products.z-wavealliance.org/products/2881/ + CEPT (Europe) + ZWA002-C + + + + + User custom mode for LED animations + + + + + + Enable/Disable Strobe over Custom Color. + + + + + + Set the rate of change to next color in Custom Mode. + + + + + Set color that LED Bulb blinks in Blink Mode. + + + + + Specifying the ramp rate when dimming using Multilevel Switch V1 CC in 100ms. + + + + Enable to send notifications to associated devices (Group 1) when the state of LED Bulb is changed. + + + + + + Adjusting the color temperature in warm white color component. + available value: 2700k to 4999k + + + + Adjusting the color temperature in cold white color component. + available value:5000k to 6500k + + + + + + true + + + + + + + + + diff --git a/openzwave/aeotec/zwa003.xml b/openzwave/aeotec/zwa003.xml new file mode 100644 index 00000000..52a5dc75 --- /dev/null +++ b/openzwave/aeotec/zwa003.xml @@ -0,0 +1,75 @@ + + + http://www.openzwave.com/device-database/0371:0003:0102 + images/aeotec/zwa003.png + https://products.z-wavealliance.org/products/2817/ + TheNanoMote Quad is a wireless, portable and rechargeable scene switch. It can control a Z-Wave device, such as smart plug, smart dimmer with a Z-Wave gateway. You can also activate a scene like sleep scene, movie scene and entertainment scene with it. + To remove the NanoMote Quad from the Z-Wave network: +(1) Insert the LIR2450 battery. +(2) Set the Z-Wave network main controller into remove mode +(see Z-Wave controller operating manual). +(3) Triple click the a button, if the exclusion is successful, LED +will blink long. + + + + Included device: +1. Insert the LIR2450 battery. +2. Set the Z-Wave network main controller into learning mode (see Z-Wave network controller operating manual). +3. Pressing and holding a button for 3 seconds. +4. If the inclusion is successful, the LED will blink in green less than for 5 seconds and then keep on for 15 seconds. + + + NanoMote Quad + Pressing and holding a button for 20 seconds. Release the button after 20 seconds, LED will keep in yellow for 3 seconds. Scene Controller will be reset to factory defaults if you short press the button within this 3 seconds. +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2820/NanoMote Quad USER MANUAL .pdf + Pressing and holding a button for 3 seconds. Led will turn to green, +which means Scene Controller has been woken up. + U.S. / Canada / Mexico + ZWA003-A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2817/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2820/xml + + https://products.z-wavealliance.org/products/2820/ + ZWA003-C + CEPT (Europe) + + + + + + Set the low battery value. + Range: 10% - 50%. + + + + + Setting the duration value of the command switch multilevel. + Available settings: 0-255. + + + + Enable/disable the buzzer alarm when battery is running low + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zwa004.xml b/openzwave/aeotec/zwa004.xml new file mode 100644 index 00000000..9cae55b0 --- /dev/null +++ b/openzwave/aeotec/zwa004.xml @@ -0,0 +1,75 @@ + + + http://www.openzwave.com/device-database/0371:0004:0102 + images/aeotec/zwa004.png + https://products.z-wavealliance.org/products/2811/ + Included device: +1. Insert the LIR2450 battery. +2. Set the Z-Wave network main controller into learning mode( see Z-Wave network controller operating manual). +3. Pressing and holding the button for 3 seconds. +4. If the inclusion is successful, the LED will blink in green less than for 5 seconds and then keep on for 15 seconds. + + + U.S. / Canada / Mexico + To remove the NanoMote One from the Z-Wave network: +(1) Insert the LIR2450 battery. +(2) Set the Z-Wave network main controller into remove mode +(see Z-Wave controller operating manual). +(3) Triple click the button, if the exclusion is successful, LED +will blink in orange for less than 5 seconds and then keep on +for 3 seconds. + + + + Pressing and holding the button for 20 seconds. Release the button after 20 seconds, LED will keep in yellow for 3 seconds. Scene Controller will be reset to factory defaults if you short press the button within this 3 seconds. +Using this procedure only in the event that the network primary controller is missing or otherwise inoperable. + NanoMote One + Pressing and holding Button for 3 seconds. Led will turn to green, +which means Scene Controller has been woken up. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2816/NanoMote One USER MANUAL .pdf + ZWA004-A + The NanoMote One is a wireless, portable and rechargeable scene switch. It can control a Z-Wave device, such as smart plug, smart dimmer with a Z-Wave gateway. You can also activate a scene like sleep scene, movie scene and entertainment scene with it. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2811/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2816/xml + + https://products.z-wavealliance.org/products/2816/ + ZWA004-C + CEPT (Europe) + + + + + + Set the low battery value. + Range: 10% - 50%. + + + + Enable send central scene notification + + + + + + Setting the duration value of the command switch multilevel. + Available settings: 0-255. + + + + Enable/disable the buzzer alarm when battery is running low + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zwa005.xml b/openzwave/aeotec/zwa005.xml new file mode 100644 index 00000000..564e0517 --- /dev/null +++ b/openzwave/aeotec/zwa005.xml @@ -0,0 +1,258 @@ + + + http://www.openzwave.com/device-database/0371:0005:0002 + images/aeotec/zwa005.png + https://products.z-wavealliance.org/products/2898/ + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2919/TriSensor user manual 20180416.pdf + Aeotec TriSensor is a universal Z-Wave Plus compatible product, consists of temperature, lighting and motion sensors, powered by a CR123A battery. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. By the built-in motion sensor, an alam will be sent to the gateway when the motion sensor is triggered. + + Press once TriSensor’s Action Button, the Purple LED will keep solid until whole network processing is complete. If the exclusion is successful, the LED will flash white -> green - +>white -> green and then LED will pulse a blue. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once. + + Press and hold the button at least 2s until Red Led is on and then release the button,device will send wakeup notification to controller if device is in a Z-Wave network. + ZWA005-C + TriSensor + Press once TriSensor’s Action Button. If it is the first installation, the yellow LED will keep solid until whole network processing is complete. If successful, the LED will flash white -> green -> white -> green, after 2 seconds finished. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once. +If it is the S2 encryption network, please enter the first 5 digits of DSK. + + 1. Power up the device. +2. Press and hold the button for 15s until Red Led is blinking,then release the button. Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2898/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2919/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2920/xml + + https://products.z-wavealliance.org/products/2919/ + ZWA005-A + U.S. / Canada / Mexico + https://products.z-wavealliance.org/products/2920/ + ZWA005-B + Australia / New Zealand + + + + + false + + + + + + This parameter is configured the delay time before PIR sensor can be triggered again to reset motion timeout counter. + Value = 0 will disable PIR sensor from triggering until motion timeout has finished. + + + + + This configures the clear time when your motion sensor times out and sends a no motion status. + + + + + This parameter is configured the sensitivity that motion detect. + 0 - PIR sensor disabled. + 1 - Lowest sensitivity. + 11 - Highest sensitivity. + + + + + + + + + + + + + + + + Enable/disable sensor binary report when motion event is detected or cleared + + + + + This parameter is configured the enabled or disabled send BASIC_SET command to nodes that associated in group 2 and group 3. + + + + + + + Define Basic Set Value when motion event is triggered and / or cleared + + + + + + + + + + This parameter is configured the threshold value that alarm level for temperature. + When the current ambient temperature value is larger than this configuration value, device will send a BASIC_SET = 0xFF to nodes associated in group 3. + If current temperature value is less than this value, device will send a BASIC_SET = 0x00 to nodes associated in group 3. + Value = [Value] x 0.1(Celsius / Fahrenheit) + Available Settings: -400 to 850 (40.0 to 85.0 Celsius) or -400 to 1185 (-40.0 to 118.5 Fahrenheit). + Default value: 239 (23.9 Celsius) or 750 (75.0 Fahrenheit) + + + + + Enable or Disable LED over TriSensor + This completely disables all LED reaction regardless of Parameter 9 - 13 settings + + + + + + + This setting changes the color of the LED when your TriSensor sends a motion report. + + + + + + + + + + + + + + This setting changes the color of the LED when your TriSensor sends a temperature report. + + + + + + + + + + + + + + This setting changes the color of the LED when your TriSensor sends a light report. + + + + + + + + + + + + + + It is possible to change the color of what the LED blinks when your TriSensor sends a battery report. + + + + + + + + + + + + + + This setting changes the color of the LED when your TriSensor sends a wakeup report. + + + + + + + + + + + + + + Configure temperature sensor scale type, Temperature to report in Celsius or Fahrenheit + + + + + + + Change threshold value for change in temperature to induce an automatic report for temperature sensor. + Scale is identical setting in Parameter No.20. + 0-> Disable Threshold Report for Temperature Sensor. + Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on Parameter No.20) to induce automatic report or setting a value of 2 will be a change of 0.2(C or F). + Available Settings: 0 to 250. + + + + + Change threshold value for change in lux to induce an automatic report for light sensor. + + + + + This parameter is configured the time interval for temperature sensor report. + This value is larger, the battery life is longer. + And the temperature value changed is not obvious. + + + + + This parameter is configured the time interval for light sensor report. + This value is larger, the battery life is longer. + And the light intensity changed is not obvious. + + + + + The current measuring temperature value can be add and minus a value by this setting. + The scale can be decided by Parameter Number 20. + Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit) + Available Settings: -200 to 200. + + + + + The current measuring light intensity value can be add and minus a value by this setting. + Available Settings: -1000 to 1000. + + + + + This configuration defines the calibrated scale for ambient light intensity. + Because the method and position that the sensor mounted and the cover of sensor will bring measurement error, user can get more real light intensity by this parameter setting. + User should run the steps as blows for calibrating + 1) Set this parameter value to default (Assumes the sensor has been added in a Z- Wave Network). + 2) Place a digital light meter close to sensor and keep the same direction, monitor the light intensity value (Vm) which report to controller and record it. + The same time user should record the value (Vs) of light meter. + 3) The scale calibration formula: k = Vm / Vs. + 4) The value of k is then multiplied by 1024 and rounded to the nearest whole number. + 5) Set the value getting in 5) to this parameter, calibrate finished. + + For example, Vm = 300, Vs = 2600, then k = 2600 / 300 = 8.6667 + k = 8.6667 * 1024 = 8874.7 => 8875. + The parameter should be set to 8875. + + + + + + + + + + + + diff --git a/openzwave/aeotec/zwa006.xml b/openzwave/aeotec/zwa006.xml new file mode 100644 index 00000000..4b7a4636 --- /dev/null +++ b/openzwave/aeotec/zwa006.xml @@ -0,0 +1,138 @@ + + + http://www.openzwave.com/device-database/0371:00B4:0003 + images/aeotec/zwa006.png + https://products.z-wavealliance.org/products/3067/ + CEPT (Europe) + Please use this procedure only when the primary controller is missing or inoperable. + +1. Make sure the device has been powered. +2. Press and hold the action button for 15 seconds. When the red LED turns on, release the button. Then, the device will enter factory reset mode. If the reset is successful, the LED will blink blue slowly. + + + + 1. Power on the device, and the power led will blink blue slowly. +2. Put the Z-Wave Primary Controller into inclusion mode (If you don’t know how to do this, refer to its manual) +3. Press and hold the action button, and when the yellow LED is on, release the button. It indicates the device has enter learn mode. +4. If added successfully, the power LED will remain green for 2 seconds, then turn off. + The Aeotec Smart Boost Timer Switch is a Z-Wave Plus enabled device and can be included/operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. +The Aeotec Smart Boost Time Switch supports consumption meter function. When the device has been included in the network, it will report the consumption power periodically. It is also a high output countdown timer that can be used to control immersion heater elements or other electrical appliances rated up to 16A. On the product, four simple white LEDs are used to show the user how much time is left to run. Pressing the switch whilst the unit is operating allows the user to cancel the timing program,and the memory function of the timer will remember the last period selected. + + Smart Boost Timer Switch + ZWA006-C + 1. Power on the device. +2. Put the Primary Controller into exclusion mode (If you don’t know how to do this refer to its manual) +3. Press and hold the action button, and when the purple LED turns on, release the button. This indicates that the device has entered learn mode. If removal is successful, the blue LED will blink slowly. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3067/Smart Boost Timer Switch User Manual-V1.9.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3067/xml + + + + + + + Action in case of power out. This parameter is used to configure the device state after power on. + + + + + + + + + Configure LED (except boost) to be off irrespective of switch status. + + + + + + + + Timer acts as auto off after specified minutes, setting is set in seconds. + 0 - no auto off with timer. + 1 ~ 86400 auto off after this specified time, unit second. + + + + + Current and overload protection + + + + + + + Configure boost time interval, unit minute. + When user press the boost button one time, the boost time will increase 30 (the value can be changed) minutes. + + + + + This parameter is used to configure the power led threshold, unit W. + When the load <= 100W, the power led will indicate yellow. + When the load > 100W, the power led will indicate orange. + When no load, the power led will indicate white. + + + + + Threshold settings for energy kWh. When the energy above the threshold, it will send a meter report command to gateway. + 0 - disable report. + 1 ~ 10000 - enable report. + + + + + Threshold settings for Watt automatic report, unit W. When Watt above the threshold, it will send a meter report command to gateway. + 0 - disable report. + 1 ~ 2500 - enable report. + + + + + Threshold settings for Current automatic report, unit 0.1A. When current above the threshold, it will send a meter report command to gateway. + 0 - disable report. + 1 ~ 150 - enable report. + + + + + Watt automatic report interval, unit second. + 0 - disable. + 65535 - enable. + + + + + kWh automatic report interval, unit second. + 0 - disable. + 65535 - enable. + + + + + Voltage automatic report interval, unit second. + 0 - disable. + 65535 - enable. + + + + + Current automatic report interval, unit second. + 0 - disable. + 65535 - enable. + + + + + + + + + + + diff --git a/openzwave/aeotec/zwa008.xml b/openzwave/aeotec/zwa008.xml new file mode 100644 index 00000000..0c60e970 --- /dev/null +++ b/openzwave/aeotec/zwa008.xml @@ -0,0 +1,121 @@ + + + + + true + + + + + + Parameter defines device operation mode. + + + + + + Parameter defines state of the sensor when the magnet is close. + If the alarm sensor is connected, it determines the output type. + Parameter inactive in external button mode (parameter Operation Mode set to 1). + + + + + + + This parameter defines events indicated by the visual LED indicator. Disabling events might extend battery life. + Values of parameters may be combined, e.g. 1+2=3 means opening/closing and wake up will be indicated by the visual indicator. + 0 - No indications. + 1 - Indication of opening/closing status change (input In). + 2 - Indication of wake up (1 x click or periodical). + 4 - Indication of device tampering. + + + + + Allows to enable activation of Z-Wave range test with double click of a Tamper Switch 2. + + + + + + + Parameter defines events which result in sending On/Off commands to devices added to the 2nd Association Group. + These commands are sent alternately to switch the devices On and Off. + Commands represent the values of BASIC SET command frames. + Parameter is inactive in external dry-contact mode (parameter Operation Mode set to 1). + + + + + + + + Command frames sent to devices added to the 2nd association group. + + + + + + + + The value of 0 turns OFF the device, 255 turns it On. + In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level. + + + + + The value of 0 turns OFF the device, 255 turns it On. + In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level. + + + + + Time period after which On command frame will be sent. + + + + + Time period after which Off command frame will be sent. + + + + + Time period after which a tamper alarm will be cancelled. + + + + + Reporting cancellation of tamper alarm to the controller and 5th Association Group. + + + + + + + The device can trigger scenes via Dry Input Terminal (external contact) using scene IDs assigned to different events. + + + + + + + The device can report Tilt Window events. + This functionality can be disabled if the device is mounted on a door or windows without tilt functionality.To disable tilt detection set the value to 0. + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zwa009.xml b/openzwave/aeotec/zwa009.xml new file mode 100644 index 00000000..729e6e6d --- /dev/null +++ b/openzwave/aeotec/zwa009.xml @@ -0,0 +1,119 @@ + + + + http://www.openzwave.com/device-database/0371:0002:0009 + images/aeotec/zwa009.png + + Water Sensor 7 Pro + CEPT (Europe) + ZWA009-C + This device measures the three air quality parameters temperature, humidity and dew point and reports them to a central controller. + Besides this, the device can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. + This can be used to establish control loops for temperature and humidity. + The device wakes up every 15 minutes to measure the values and it will send unsolicited reports when values change. + Additionally, the device will report all values on request. + The AërQ Sensor is actively monitoring the danger of mould in a room based on the temperature and humidity and will issue alarm warnings when critical air conditions met. + Wireless Alarm and red and a green blinking LED will indicate a mould condition. + This local LED warning function is also available when the device is not included in any Z-Wave network and works stand alone. + + Press the button once + 1. Insert the battery. + 2. Press the button quickly three times in a row. + + 1. Press the button quickly three times in a row. + + Keep the button pressed for 10 seconds. Then the green LED will start blinking. + Release the button, when the LED stops blinking. Your device is reset to factory default now. + + https://aeotec.freshdesk.com/support/solutions/folders/6000236759 + https://aeotec.freshdesk.com/support/solutions/folders/6000236759 + + Initial Config File + + + + + + true + + + + + + This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline. + If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. + However, periodic reports, managed by configuration parameter 4, may still be active. + + + + This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline. + If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. + However, periodic reports, managed by configuration parameter 4, may still be active. + + + + This parameter defines the time interval to send an unsolicited report. + If the value is set to 0, there will be no periodic reports sent to the controller. + However, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active. + + + + This parameter defines a temperature. + If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2 + + + + This parameter defines a temperature. + If the measured temperature dropps below this watermark a BASIC command is sent into Association Group 3 + + + + This parameter defines a relative humidity. + If the measured relative humidity surpasses this watermark a BASIC command is sent into Association Group 4 + + + + This parameter defines a relative humidity. + If the measured temperature drops below this relative humidity a BASIC command is sent into Association Group 5 + + + + This defines what BASIC command shall be sent out into association group 3 + + + + This defines what BASIC command shall be sent out into association group 2 + + + + This defines what BASIC command shall be sent out into association group 5 + + + + This defines what BASIC command shall be sent out into association group 4 + + + + This value allows to increase the humidity threshold for mould danger notification by max 10% + + + + This parameter helps reset configuration parameters and the device to factory defaults + + + + + + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zwa012.xml b/openzwave/aeotec/zwa012.xml new file mode 100644 index 00000000..6e722635 --- /dev/null +++ b/openzwave/aeotec/zwa012.xml @@ -0,0 +1,151 @@ + + + + http://www.openzwave.com/device-database/0371:0002:000C + images/aeotec/zwa012.png + https://products.z-wavealliance.org/products/3866/ + Door / Window Sensor 7 Pro + CEPT (Europe) + ZWA012-C + Aeotec Door/ Window Sensor 7 Pro is built on the 700 series Z-Wave technology. + Its a small window position sensor for your smart home, it monitors window and their exact opening position and lets your know when a window is tilted or completely opened. + It also supports connecting external binary sensors with a dry contact through the dry binary contact of the Door/ Window sensor. + Using the latest technology it supports the highest Z-Wave security level of S2 and SmartStart. + + Press the tamper once + 1. Open the housing. + 2. Remove the battery protection. + 3. Press the tamper on the side of the appliance three times quickly. + + 1. Open the housing. + 2. Press the tamper on the side of the appliance three times quickly. + + Reset to factory default + This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable. + Once Cover is removed and the tamper switch is tripped, push the tamper for 5 seconds until the RED LED + blinks once. Then release tamper and push it again for 5 seconds while the RED LED is blinking until the + GREEN LED blinks once. + + https://aeotec.freshdesk.com/support/solutions/folders/6000237099 + https://aeotec.freshdesk.com/support/solutions/folders/6000237099 + + Initial Config File + + + + + + true + + + + + + This parameter defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. + There is always one input active only. + The other sensor input the deactivated. + + + + + + This parameter defines the polarity of the magnet sensor. + + + + + + This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life. + + + + No Indications + + + + Open/Close Status Change + + + + Wake Up + + + + Device Tampering + + + + Allows to enable activation of Z-Wave range test with double click of a Tamper Switch. + + + + + + This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2. + + + + + + + Command frames sent to devices added to the 2nd association group. + + + + + + + The value of 0 turns OFF the device, 255 turns it On. + In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level. + + + + The value of 0 turns OFF the device, 255 turns it On. + In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level. + + + + Time period after which On command frame will be sent. + + + + Time period after which Off command frame will be sent. + + + + Time period after which a tamper alarm will be cancelled. + + + + Reporting cancellation of tamper alarm to the controller and 5th Association Group. + + + + + + This parameter enables/disables the central scene function. + + + + + + This parameter enables/disables the tilt function. + + + + + + You can use this parameter to adjust the tilt sensitivity if the tilt is too low or too high. + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zwa019.xml b/openzwave/aeotec/zwa019.xml new file mode 100644 index 00000000..f9cda345 --- /dev/null +++ b/openzwave/aeotec/zwa019.xml @@ -0,0 +1,136 @@ + + + + http://www.openzwave.com/device-database/0371:0002:0013 + images/aeotec/zwa019.png + https://products.z-wavealliance.org/products/3872/ + Water Sensor 7 Pro + CEPT (Europe) + ZWA019-C + The Water Sensor 7 pro brings more safety into your home. + With its flexible sensor probe and the sensitive sensor point it detects the presence and absence of water at any given location. + Furthermore the Watersensor 7 pro is enabled to accurately measure the temperature and humidity of its environment, so you are always informed about your room climate. + Thanks to the latest Z-Wave 700 series technology, the Water Sensor 7 is distinguished with and increased range, S2 Security, OTA FW update and SmartStart. + + Press the tamper once + 1. Open the housing. + 2. Remove the battery protection. + 3. Press the tamper on the side of the appliance three times quickly. + + 1. Open the housing. + 2. Press the tamper on the side of the appliance three times quickly. + + Reset to factory default + This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable. + Once Cover is removed and the tamper switch is tripped, push the tamper for 5 seconds until the RED LED + blinks once. Then release tamper and push it again for 5 seconds while the RED LED is blinking until the + GREEN LED blinks once. + + https://aeotec.freshdesk.com/support/solutions/folders/6000236794 + https://aeotec.freshdesk.com/support/solutions/folders/6000236794 + + Initial Config File + + + + + + true + + + + + + This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life. + + + + No Indications + + + + Water Leakage Status Change + + + + Wake Up + + + + Device Tampering + + + + Allows to enable activation of Z-Wave range test with double click of a Tamper Switch. + + + + + + This parameter defines the status of the water leakage that causes sending a BASIC command to all devices of Association Group 2. + + + + + + + Command frames sent to devices added to the 2nd association group. + + + + + + + The value of 0 turns OFF the device, 255 turns it On. + In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level. + + + + The value of 0 turns OFF the device, 255 turns it On. + In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level. + + + + Time period after which On command frame will be sent. + + + + Time period after which Off command frame will be sent. + + + + Time period after which a tamper alarm will be cancelled. + + + + This parameter defines if the alarm cancellation event is reported. + + + + + + This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline. + If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 18, may still be active. + + + + This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline. + If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 18, may still be active. + + + + This parameter defines the time interval to send an unsolicited report. + If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 16 and 17, may still be active. + + + + + + + + + + + + + diff --git a/openzwave/aeotec/zwa021.xml b/openzwave/aeotec/zwa021.xml new file mode 100644 index 00000000..ac67fc5c --- /dev/null +++ b/openzwave/aeotec/zwa021.xml @@ -0,0 +1,144 @@ + + + http://www.openzwave.com/device-database/0371:0015:0002 + images/aeotec/zwa021.png + https://products.z-wavealliance.org/products/3627 + Start Inclusion mode of your primary Z-Wave Controller. + Press the Boost-Button. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=product_documents/3627/RadiatorThermostat_Mainmanual.pdf + Start Exclusion mode of your primary Z-Wave Controller. + Now press and hold the boost button of the Spirit Z-Wave Plus for at least 5 seconds. + Aeotec Radiator Thermost + 4251295701387 + UAE + Please use this procedure only when the network primary controller is missing or otherwise inoperable. + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3627/RadiatorThermostat_Mainmanual.pdf + Remove batteries. + Press and hold boost button. + While still holding boost button insert batteries. + The LCD shows RES. Release boost button. + To perform the factory reset press boost button. + + With the Aeotec Radiator Thermostat you get many functions. It regulates the room temperature to your comfort. For the best use it is equipped with FLiRS (Frequently Listening Receiver Slave) and reacts immediately to incoming commands of the Z-Wave controller. Furthermore the device is able to be connected to an external Z-Wave temperature sensor. Because of that the thermostat refers to the temperature of the external sensor, which can be placed in the middle of the room. + + The display of the thermostat has a background light and has a big LCD screen. Besides you can also lock the local buttons as a child protection. + + The multicolor LED of the central button allows a intuitive usability because the User is invited to follow the instruction based on the blinking LED of the middle butto. + + The TRV can either be used as heating thermostat or as a actuator depending on the configuration of the device. The measured temperature or the position of the actuator of the thermostat are transfered to the Z-Wave gateway. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3627 + ProductPic + + https://products.z-wavealliance.org/products/3627 + 4251295701387 + UAE + + + + + + + + + + + Off: No heating, only frost protection. + Heat: Room temperature will be kept at the configured setpoint. + Heat Eco: Energy save heating mode. Room temperature will be lowered to the configured eco setpoint in order to save energy. + Full Power: Full power heating. This mode is left automatically after 5 minutes. + Manufacturer Specific: Direct valve control mode. The valve opening percentage can be controlled using the switch multilevel command class. + + + + + + + + + + + + + + + + + + + + + + 0 + false + + + + + + + + Allows rotating the LCD contents by 180 degrees. + Default: Normal + + + + + + + 0: No Timeout, LCD always on. + 5-30: Timeout after 5-30s. + Default: 0 (LCD always on) + + + + + Default: Backlight enabled + + + + + + + Default: Send once a day + + + + + + + 0: Don't send temperature automatically. + 1-50: Report temperature at 0.1-5.0°C temperature difference. + Default: 5 (Delta = 0.5°C) + + + + + 0: Don't send Valve opening percentage automatically. + 1-100: Report valve opening percentage at a delta of 1-100%. + Default: 0 + + + + + Default: Medium sensibility + + + + + + + + + 206-255: -5.0 to -0.1°C. + 0-50: 0°C-5°C. + 128: External Temperature Sensor. + Default: 0 (0.0°C Offset) + + + + diff --git a/openzwave/airlinemechanical/zds-ud10.xml b/openzwave/airlinemechanical/zds-ud10.xml new file mode 100644 index 00000000..dbfab0b7 --- /dev/null +++ b/openzwave/airlinemechanical/zds-ud10.xml @@ -0,0 +1,15 @@ + + + http://www.openzwave.com/device-database/0111:0200:8200 + images/airlinemechanical/zds-ud10.png + https://products.z-wavealliance.org/products/106/ + AMC Dimming Switch Module + NDS/ZDS-UD10 + Z-Wave US Plug-in Switch/Dimmer + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/106/xml + + + + diff --git a/openzwave/alfred/DB2.xml b/openzwave/alfred/DB2.xml new file mode 100644 index 00000000..08e550e2 --- /dev/null +++ b/openzwave/alfred/DB2.xml @@ -0,0 +1,41 @@ + + + DB2 Z-Wave Accessory + Connect a DB2 or DB2-B to your smart hub using this easy to install Z-Wave module + http://www.openzwave.com/device-database/021D:0001:0003 + images/alfred/DB2.png + https://alfredinc.com/collections/products/products/zwave-module + https://alfredinc.com/pages/support + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3324/Alfred Z-Wave Plus System Integrators Guide V5.1.pdf + + Follow the user guide of hub to enter inclusion mode. +-Operate on lock following guide below: +1.Enter master mode(refer to programming instruction) +2.Input “8” to enter “function extension settings” +3.Input “1” to join a network. + Follow the user guide of hub to enter exclusion mode. +-Operate on lock following guide below: +1.Enter master mode(refer to programming instruction) +2.Input “8” to enter “function extension settings” +3.Input “2” to log off a network. + Please use this procedure only when the network primary controller is missing or inoperable. +-Operations on lock +1.Open the door and keep the lock in "unlock" status +2.Open battery box and find the reset button. +3.Use a sharp thing to press and hold the reset button. +4.Keep holding the reset button and remove a battery from battery box then replace it. +5.Keep holding the reset button until hearing voice guide. + https://products.z-wavealliance.org/products/3324 + + Initial file based on z-wavealliance.org + + + + + + + + + + diff --git a/openzwave/assa_abloy/ConexisL1.xml b/openzwave/assa_abloy/ConexisL1.xml new file mode 100644 index 00000000..de2a7111 --- /dev/null +++ b/openzwave/assa_abloy/ConexisL1.xml @@ -0,0 +1,121 @@ + + + http://www.openzwave.com/device-database/0129:0002:6600 + images/assa_abloy/ConexisL1.png + https://products.z-wavealliance.org/products/2535/ + Features: + +Control Via Smartphone - Configure, Control and unlock your Smart Door Lock from your smartphone via our secure Bluetooth App. + +Keyless - Say goodbye to keys, Open your Smart Door lock via your smartphone, Key Card or Key Tag. + +Simple to Fit - Engineered for easy installation. + +Connectivity - Compatible with the Yale Smart Home system. (Yale module sold separately) + +Security as standard - Built in tamper alarm, PAS24 accredited. + +Battery Operated - Powered by 4 AA batteries and a warning when they're running low. + +Battery Backup - A 9v battery connection port can be used to power the Smart door lock in the event of flat batteries. + +Secure Push & Turn Thumbturn - Engineered to give additional convenience and security to your door + CEPT (Europe) + SD-L1000-CH + Put the Z-Wave controller into add or learn mode + +Press the R button on the lock 3 times quickly (within 1.5 seconds) + +Refer to the operation manual of the Z-Wave controller to complete the learn in process + +For more information on this please visit: +www.yale.co.uk/smart-living + + Only use this when the existing Z-Wave controller is missing or inoperable + + Lift up the lever handle + +While holding the handle up, press the R button 3 times within 1.5 seconds + + Put the existing Z-Wave controller into Remove Mode + +Press the R button on the lock 3 times quickly (within 1.5 secs) + +The lock is now ready to be added to a new Z-Wave controller + +For more information on this please visit: +www.yale.co.uk/smart-living + + + Conexis L1 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2535/Instruction Manual V2a.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2535/xml + + + + + + + Volume of the keypad tones and any voice prompts (default = 3, high) + + + + + + Enable or disable the Auto relock feature (default = 255, enable) + + + + + After successful local unlock, automatically relock after the specified time (default = 7 seconds) + + + + Number of incorrect tags before lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable for the time specified by Wrong tag timeout parameter. (5 = default) + + + + + + + + + + + + + + + + + + + + + + + + Number of seconds unit will be inoperable after number of Wrong tag attempts is exceeded (30 = default) + + + + + + + + + + + + + + + diff --git a/openzwave/assa_abloy/KeyfreeConnected-plus.xml b/openzwave/assa_abloy/KeyfreeConnected-plus.xml new file mode 100644 index 00000000..e0d4b347 --- /dev/null +++ b/openzwave/assa_abloy/KeyfreeConnected-plus.xml @@ -0,0 +1,105 @@ + + + http://www.openzwave.com/device-database/0129:0001:0007 + images/assa_abloy/KeyfreeConnected-plus.png + https://products.z-wavealliance.org/products/2576/ + Put the Z-Wave controller into add mode + +Enter the Master code on the lock, followed by # + +Press the 4 button, followed by # + +Press the 1 button followed by # + +Refer to the operation manual of the Z-Wave controller to complete the add/inclusion process + +For more information on this please visit: +www.yale.co.uk/smart-living + + Put the Z-Wave controller into remove mode + +Enter the Master code on the lock, followed by # + +Press the 4 button, followed by # + +Press the 2 button followed by # + +Refer to the operation manual of the Z-Wave controller to complete the remove/exclusion process + +For more information on this please visit: +www.yale.co.uk/smart-living + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2743/Instruction Manual V2b.pdf + Keyfree Connected Ready smart lock + +Features + + Battery operated + Low battery indicator with emergency battery connection + User codes and settings remain if batteries are replaced + 3 minute lock out if code is entered incorrectly 5 times + Tamper alarm + For use on UPVC & Composite Doors + 2 year guarantee + + Keyfree Connected + Enter the Master code on the lock, followed by # + +Press the 4 button, followed by # + +Press the 0 button followed by # + +Please use this procedure only when the network controller is missing or inoperable + CEPT (Europe) + YD-01-CON + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2576/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2743/xml + + https://products.z-wavealliance.org/products/2743/ + CEPT (Europe) + YKFCON + + + + + + + Volume of the keypad tones and any voice prompts (default = 3, high) + + + + + + Enable or disable the Auto relock feature (default = 255, enable) + + + + + After successful local unlock, automatically relock after the specified time (default = 7 seconds) + + + After successful remote unlock, automatically relock after the specified time (default = 10 seconds) + + + + + + + + + + + + + + + diff --git a/openzwave/assa_abloy/KeyfreeConnected.xml b/openzwave/assa_abloy/KeyfreeConnected.xml new file mode 100644 index 00000000..2b7618cb --- /dev/null +++ b/openzwave/assa_abloy/KeyfreeConnected.xml @@ -0,0 +1,23 @@ + + + http://www.openzwave.com/device-database/0129:0000:0007 + images/assa_abloy/KeyfreeConnected.png + https://products.z-wavealliance.org/products/1399/ + Yale Keyless Connected YD-01-CON + Keyless Connected with Z-Wave for Rim locks + YD-01-CON + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1399/xml + + + + + + + + + diff --git a/openzwave/assa_abloy/PushButtonDeadbolt.xml b/openzwave/assa_abloy/PushButtonDeadbolt.xml new file mode 100644 index 00000000..04bf00fc --- /dev/null +++ b/openzwave/assa_abloy/PushButtonDeadbolt.xml @@ -0,0 +1,128 @@ + + + http://www.openzwave.com/device-database/0129:0000:0004 + images/assa_abloy/PushButtonDeadbolt.png + https://products.z-wavealliance.org/products/687/ + Yale Real Living® Assure Lock™ Interconnect combines electronic deadbolts with the convenience of a passage lever for panic proof egress. From the inside, both the latchbolt and the deadbolt are retracted simultaneously in a single motion for a quick and easy exit. Ships with Z-Wave Plus Smart Module. + U.S. / Canada / Mexico + Yale/YRD/ 210 + http://www.yalerealliving.com + Yale Real Living® Assure Lock™ Interconnected Z-Wave Enabled Push Button Deadbolt + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/687/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1039/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1971/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3239/xml + Fixed index of alarm message to trigger lock status refresh + + https://products.z-wavealliance.org/products/1039/ + YRD110-ZW-US + U.S. / Canada / Mexico + https://products.z-wavealliance.org/products/3239/ + Enter the 4-8 master Pin code followed by the gear key. +Press the 7 key followed by the gear key +Press the 1 key followed by the gear key + Remove the battery cover and batteries. +Remove the interior escutcheon to access the reset button. +The reset button is located above the PCB cable connector. +While pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button. +Replace battery cover. +Please use this procedure only when the network primary controller is missing or otherwise inoperable + YRC216-ZW2 + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3239/YRC216_YaleRealLivingAssureDeadbolt_Z-WavePlus_SystemIntegratorsGuide.pdf + Enter the 4-8 digit master pin code followed by the gear key +Press the 7 key followed by the gear key +Press the 3 key followed by the gear key + + + + + + Disable the door sensor alarm function. + + + + + + + + + + seconds; after successful code entry and unit unlocks, it will automatically re-lock after specified time (30 = default value) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + number of seconds unit will be inoperable after number of wrong code entries is exceeded (30 = default) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/assa_abloy/PushButtonLever.xml b/openzwave/assa_abloy/PushButtonLever.xml new file mode 100644 index 00000000..4e8fd002 --- /dev/null +++ b/openzwave/assa_abloy/PushButtonLever.xml @@ -0,0 +1,63 @@ + + + + + + + + Disable the door sensor alarm function. + + + + + + + + + + seconds; after successful code entry and unit unlocks, it will automatically re-lock after specified time (30 = default value) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + number of seconds unit will be inoperable after number of wrong code entries is exceeded (30 = default) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/assa_abloy/TouchDeadbolt.xml b/openzwave/assa_abloy/TouchDeadbolt.xml new file mode 100644 index 00000000..733f870d --- /dev/null +++ b/openzwave/assa_abloy/TouchDeadbolt.xml @@ -0,0 +1,148 @@ + + + http://www.openzwave.com/device-database/0129:0000:0002 + images/assa_abloy/TouchDeadbolt.png + https://products.z-wavealliance.org/products/631/ + U.S. / Canada / Mexico + http://www.yalerealliving.com + Never worry about carrying around or losing your keys again. Unlock and lock your home with ease from the backlit touchscreen keypad. Create unique pin codes for friends and family and remove codes whenever you need to. This Yale Real Living lock features Z-Wave technology and seamlessly integrates into 50+ home automation and security systems. When added to most Z-Wave automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere. The lock is tamper resistant, easy to install and even easier to use! + + Yale Assure Lock with Bluetooth Z-Wave Enabled Touch Screen Deadbolt + Yale/YRD/ 220 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/631/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1040/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1358/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1878/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1972/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1973/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2402/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2403/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3211/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3251/xml + Fixed index of alarm message to trigger lock status refresh + + https://products.z-wavealliance.org/products/1040/ + U.S. / Canada / Mexico + YRD120-ZW-US + https://products.z-wavealliance.org/products/2403/ + 05-3109-1-00-60-11 + CEPT (Europe) + https://products.z-wavealliance.org/products/3211/ + YRD256-ZW2 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3251/YRD426_YaleRealLivingAssureDeadbolt_Z-WavePlus_SystemIntegratorsGuide_.pdf + Please use this procedure only when the network primary controller is missing or otherwise inoperable. +1. Remove the inside lever with the lever removal tool. +2. Remove battery cover using hex wrench provided with lock. +3. Remove four (4) AA batteries. +4. Remove the 10-32 x 3/4" pan head screw from the center of the battery housing into the barrel nut of the outside assembly. +5. Remove inside escutcheon. Cables may stay connected. +6. Reinstall batteries +7. On the back of the PC board, push and hold the Reset Button with the lever removal tool for 3 seconds. +8. While continuing the press the reset button, temporarily remove one AA battery. +9. Reinstall the battery +10. Release reset button and wait 15 seconds. Speaker will announce "Welcome to Yale" +11. Reassemble escutcheon + 1. Enter the 4-8 digit master PIN code followed by the gear key. +2. Press the 7 key followed by the gear key. +3. Press the 3 key followed by the gear key. + 1. Enter the 4-8 digit master PIN code followed by the gear key. +2. Press the 7 key followed by the gear key. +3. Press the 1 key followed by the gear key. + U.S. / Canada / Mexico + https://products.z-wavealliance.org/products/3251/ + YRD426-ZW2 + U.S. / Canada / Mexico + + + + + + Disable the door sensor alarm function. + + + + + + + + + + + seconds; after successful code entry and unit unlocks, it will automatically re-lock after specified time (30 = default value) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + number of seconds unit will be inoperable after number of wrong code entries is exceeded (30 = default) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/assa_abloy/TouchLever.xml b/openzwave/assa_abloy/TouchLever.xml new file mode 100644 index 00000000..a86e97ea --- /dev/null +++ b/openzwave/assa_abloy/TouchLever.xml @@ -0,0 +1,86 @@ + + + http://www.openzwave.com/device-database/0129:0000:0001 + images/assa_abloy/TouchLever.png + https://products.z-wavealliance.org/products/686/ + U.S. / Canada / Mexico + http://www.yalerealliving.com + Yale/YRL/210 + Yale Real Living Push Button Lever Lock + Yale Real Living deadbolt and lever locks are the first products in the Yale Real Living™ (www.yalerealliving.com) portfolio of home control and security solutions. Available in both durable acrylic touchscreen or simple, elegant, tamper-resistant keypad, Yale's new platform of intelligent locks support Z-Wave, allowing them to integrate seamlessly into a wide range of home control and security systems. + +Regardless of the home control system employed, users will have access to a high degree of functionality, including the ability to lock and unlock doors from web-enabled devices or create customized entry scenes for family members, neighbors and guests. Features of Yale Real Living locks include personalized access-control scenes for up to 250 users; access to all user programmable settings via select user interfaces; plus the touchscreen versions employ voice assisted programming in English, Spanish and French. The new intelligent locks offer an elegant, next-generation home control solution for entryways and protected interior doors to make everyday living easier and safer. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/686/xml + + + + + + + Disable the door sensor alarm function. + + + + + + + + + + + seconds; after successful code entry and unit unlocks, it will automatically re-lock after specified time (30 = default value) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + number of seconds unit will be inoperable after number of wrong code entries is exceeded (30 = default) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/assa_abloy/nexTouch.xml b/openzwave/assa_abloy/nexTouch.xml new file mode 100644 index 00000000..388ff242 --- /dev/null +++ b/openzwave/assa_abloy/nexTouch.xml @@ -0,0 +1,135 @@ + + + http://www.openzwave.com/device-database/0129:0B00:8003 + images/assa_abloy/nexTouch.png + https://products.z-wavealliance.org/products/2439/ + nexTouch Wireless Key Free Push Button with Z-Wave + NTB620-ZW2 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2440/nexTouch TS Manual for Cert.pdf + 1. Enter the 4-8 digit master PIN code followed by the gear key. +2. Press the 7 key followed by the gear key. +3. Press the 3 key followed by the gear key. + U.S. / Canada / Mexico + Please use this procedure only when the network primary controller is missing or otherwise inoperable. +1. Remove the inside lever with the lever removal tool. +2. Remove battery cover using hex wrench provided with lock. +3. Remove four (4) AA batteries. +4. Remove the 10-32 x 3/4" pan head screw from the center of the battery housing into the barrel nut of the outside assembly. +5. Remove inside escutcheon. Cables may stay connected. +6. Reinstall batteries +7. On the back of the PC board, push and hold the Reset Button with the lever removal tool for 3 seconds. +8. While continuing the press the reset button, temporarily remove one AA battery. +9. Reinstall the battery +10. Release reset button and wait 15 seconds. Speaker will announce "Welcome to Yale" +11. Reassemble escutcheon + Yale nexTouch™ provides small business owners a wireless access management solution with the security of commercial grade locks and the convenience and cost-efficiency of wireless installation. The nexTouch product is a keypad access lock designed to meet most small business applications, both interior and exterior. The lock can be paired with a Z-Wave system for easy integration into new and existing alarm and automation platforms. + +Yale nexTouch offers many benefits for the small business owner, including easy management of employee access rights and attendance, seeing to unattended deliveries, monitoring of business hours, managing remote locations, and increased security. Lock features may vary based on the chosen integration system, but typically include accommodation of up to 500 users, real-time notifications, audit trail, scheduling of access rights and remote access. To meet small business security needs Yale nexTouch locks are ANSI/BHMA Grade 1 certified, UL listed for use on fire doors and windstorm listed. The product is designed for standard commercial doors, ideal for employee, delivery or back entrances. The lock is available with a backlit push button or touchscreen keypad, the latter offering low battery and tamper alarm indicators on the device. + 1. Enter the 4-8 digit master PIN code followed by the gear key. +2. Press the 7 key followed by the gear key. +3. Press the 1 key followed by the gear key. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1857/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1970/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2439/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2440/xml + + https://products.z-wavealliance.org/products/2440/ + NTB630-ZW2 + U.S. / Canada / Mexico + + + + + + Disable the door sensor alarm function. + + + + + + + + + + + seconds; after successful code entry and unit unlocks, it will automatically re-lock after specified time (30 = default value) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + number of seconds unit will be inoperable after number of wrong code entries is exceeded (30 = default) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/assa_abloy/yrd1x0.xml b/openzwave/assa_abloy/yrd1x0.xml new file mode 100644 index 00000000..f1104e6e --- /dev/null +++ b/openzwave/assa_abloy/yrd1x0.xml @@ -0,0 +1,115 @@ + + + YRD110/YRD120 Keyless Deadbolt + Yale Real Living® keyless deadbolt. These push button and touchscreen deadbolts are designed to seamlessly integrate into your smart home to provide you and your family with security and convenience. + http://www.openzwave.com/device-database/0129:0800:0004 + https://us.yalehome.com/en/products/yale-assure-lock-and-levers/b1l-and-t1l-lock + https://support.shopyalehome.com/ + images/assa_abloy/yrd1x0.png + https://us.yalehome.com/Yale/Yale%20US/Support/B1L%20and%20T1L%20Locks/AYRD_110_INST_FUL%20Rev%20G%20WEB.pdf + Method 1: +Remove the battery cover +Press zwave buttton (right side near top) and hold until beeps 2 times +Release button and network joining automatically begins +Replace battery cover +Method 2: +Enter the master Pin code followed by the gear key. +Press the 7 key followed by the gear key +Press the 1 key followed by the gear key + Method 1: +Remove the battery cover +Press zwave buttton (right side near top) and hold until beeps 5 times +Release button and network removal automatically begins +Replace battery cover +Method 2: +Enter the master Pin code followed by the gear key. +Press the 7 key followed by the gear key +Press the 3 key followed by the gear key + Remove the battery cover and batteries +While pressing the reset button (left side near top) for a minimum of 3 seconds, reinstall batteries +Release reset button. +Replace battery cover +Please use this procedure only when the network primary controller is missing or otherwise inoperable + https://products.z-wavealliance.org/products/1039/ + YRD110-ZW-US + U.S. / Canada / Mexico + https://products.z-wavealliance.org/products/1040/ + U.S. / Canada / Mexico + YRD120-ZW-US + + Split out from PushButtonDeadbolt.xml + + + + + + (On = default) + + + + + (Off = default) + + + + + after successful code entry and unit unlocks, it will automatically re-lock after specified number of seconds (30 = default) + + + + The number of invalid code entries lock will accept before sending TAMPER Alarm. + When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default) + + + + + + + + + + + number of seconds unit will be inoperable after number of wrong code entries is exceeded (60 = default) + + + Normal Mode: Master code and all user codes enabled (default). +Vacation Mode: Master code enabled, all user codes disabled. +Privacy Mode: Master code and all user codes disabled. + + + + + + (On = default) + + + + + (Off = default) + + + + + (Off = default) + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/august/asl-03.xml b/openzwave/august/asl-03.xml new file mode 100644 index 00000000..fe8ec05c --- /dev/null +++ b/openzwave/august/asl-03.xml @@ -0,0 +1,45 @@ + + + http://www.openzwave.com/device-database/033F:0001:0001 + images/august/asl-03.png + https://products.z-wavealliance.org/products/2624/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2624/August Z-Wave Required Documentation.pdf + Any operation (manual, RF, etc.) will wake up the lock. + August Smart Lock Rev 3 + In order to include the August Smart Lock on to a Z-Wave network the user will have to do the following: +1. Open the August app +2. Go to the Lock Settings screen +3. Select Z-Wave Settings +4. Select Add To A Z-Wave Network +5. Put the controller into inclusion mode and select My Hub is in Inclusion Mode on the August app + In order to exclude the August Smart Lock from a Z-Wave network the user will have to do the following: +1. Open the August app +2. Go to the Lock Settings screen +3. Select Z-Wave Settings +4. Select Remove Z-Wave Device +5. Put the controller into exclusion mode and select My Hub is in Exlusion Mode on the August app + Give your customer total control over their front door, from anywhere. The August Smart Lock Pro is the leading Z-Wave Plus retrofit smart lock. You can lock and unlock your door, create virtual keys for guests, and keep track of who comes and goes with a 24/7 activity log, all from your iOS or Android smartphone. The August Smart Lock Pro features Z-Wave Plus and BLE and it is the only lock to support the three leading voice-assistants, Siri, Google Assistant, and Amazon Alexa. The lock quickly installs on the inside of your door with just a screwdriver. Keep your exterior door hardware exactly as it is and use your traditional key any +time. + ASL-03 + In order to reset the August Smart Lock the user will have to do the following: +1. Open the August app +2. Go to the Lock Settings screen +3. Select Z-Wave Settings +4. Select Remove Z-Wave device +5. Select My Hub Is No Longer Working +6. Caution: Resetting a Z-Wave device without telling the hub can cause performance issues. Use this procedure only when the Z-Wave hub is missing or otherwise inoperable. +7. Select Reset Z-Wave Device +8. On the Reset Z-Wave Device? prompt select Reset + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2624/xml + + + + + + + + + + diff --git a/openzwave/buffalo/hw-100v15a-zw.xml b/openzwave/buffalo/hw-100v15a-zw.xml new file mode 100644 index 00000000..40f71fcd --- /dev/null +++ b/openzwave/buffalo/hw-100v15a-zw.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/0145:0004:0001 + images/buffalo/hw-100v15a-zw.png + https://products.z-wavealliance.org/products/802/ + Buffalo HW-100V15A-ZW + Smat Tap 100V/15A measure & monitor power + Japan + HW-100V15A-ZW + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/802/xml + + + diff --git a/openzwave/building36/b36-t10.xml b/openzwave/building36/b36-t10.xml new file mode 100644 index 00000000..3ab2d79c --- /dev/null +++ b/openzwave/building36/b36-t10.xml @@ -0,0 +1,253 @@ + + + + Building 36 Intelligent Thermostat + The Building 36 Intelligent Thermostat gives you remote access and control of your thermostat. Enjoy effortless energy management, climate and ambiance control, custom automation and measurable results. Create custom smart schedules that automate your thermostat. Receive critical temperature alerts to know instantly when your thermostat reaches preset limits. Save energy by using location-based automation to have your thermostat adjust itself while you're out. + http://www.openzwave.com/device-database/0190:0001:0001 + images/building36/b36-t10.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1161/Product_Manual_11_25_14-spreads_B36.pdf + Short press any button + Press and hold the DOWN button on the thermostat to begin inclusion mode. Release the button when the RADIO icon lights up. + Set the thermostat to OFF mode. Press and hold the DOWN button on the thermostat to enter exclusion mode. Release the button when the RADIO icon lights up. + https://products.z-wavealliance.org/products/1161 + U.S. / Canada / Mexico + B36-T10 + + Added device + Bump revision + + + + + 64 + + + + + + + + Air Temperature Sensor Value + + + Humidity Sensor Value + + + Air Temperature Sensor Available Units + + + + + Humidity Sensor Available Units + + + + + + + + Set the Thermostat Mode + + + + + + + + + + + + + + + + + Set the Thermostat Operating State + + + + + + + Set the Thermostat target heating temperature + + + Set the Thermostat target cooling temperature + + + + + + + + + + + + + + + + + + + Set the Fan Mode + + + + + + + + + + + + + + + Set the Fan State + + + + + + + + + + + ZWave+ Version Supported on the Device + + + Icon File to use for the Installer Application + + + Icon File to use for the User Application + + + + + + + + + + + Revision of the Config file currently loaded + + + Revision of the Config file on the File System + + + Latest Revision of the Config file available for download + + + + + + + Output RF PowerLevel + + + + + + + + + + + + + Timeout till the PowerLevel is reset to Normal + + + Apply the Output PowerLevel and Timeout Values + + + Node to Perform a test against + + + PowerLevel to use for the Test + + + + + + + + + + + + + How Many Messages to send to the Node for the Test + + + Perform a PowerLevel Test against the a Node + + + Get the results of the latest PowerLevel Test against a Node + + + The Current Status of the last PowerNode Test Executed + + + + + + Number of Messages successfully Acked by the Target Node + + + + + + + Current Battery Level + + + + + + + Day of Week + + + + + + + + + + Hour + + + Minute + + + + + + + + + + + + + + + + Z-Wave Library Version + + + Z-Wave Protocol Version + + + Application Version + + + diff --git a/openzwave/comfort/ucm.xml b/openzwave/comfort/ucm.xml new file mode 100644 index 00000000..4c249780 --- /dev/null +++ b/openzwave/comfort/ucm.xml @@ -0,0 +1,15 @@ + + + http://www.openzwave.com/device-database/0030:0001:0001 + images/comfort/ucm.png + https://products.z-wavealliance.org/products/833/ + The UCM/Zwave is a gateway to Z-Wave which allows users to control Z-Wave modules from the telephone, keypads, touchscreens and any user interface used with Comfortintegrated Intruder Alarm and Home Automation system + UCM/Zwave + Cytech UCM/ZWave + CEPT (Europe) + http://www.cytech.biz/zwave_interface_eu.html?category_id=74 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/833/xml + + + diff --git a/openzwave/config-template.xml b/openzwave/config-template.xml new file mode 100644 index 00000000..10117100 --- /dev/null +++ b/openzwave/config-template.xml @@ -0,0 +1,76 @@ + + + + + + http://www.openzwave.com/device-database/XXXX:YYYY:ZZZZ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Small Description of what this config param does. + + + + + Short Help Description + + + + + + + Short Help Description + + + + + Help text that describes what this Param does over all + + + + What Bit 1 Does + + + + What Bit 5 Does + + + + + + + false + + + + + + + + + diff --git a/openzwave/connecthome/ch-201.xml b/openzwave/connecthome/ch-201.xml new file mode 100644 index 00000000..27f19e46 --- /dev/null +++ b/openzwave/connecthome/ch-201.xml @@ -0,0 +1,133 @@ + + + + CH-201 Thermostat + CH-201 thermostat is a Z-Wave device designed to maintain the set temperature. The thermostat can control the heating element directly (electric floor heating, electric heater, etc.) or with additional equipment (thermoelectric drive, etc.) The thermostat is equipped with a digital temperature sensor, but can work with any other temperature sensor if necessary Your Z-Wave network. + http://www.openzwave.com/device-database/0179:0001:0001 + https://connecthome.com.ua/product/ch201 + https://connecthome.com.ua/index.php?route=information/contact + images/connecthome/CH_201.png + https://connecthome.com.ua/product/ch201 + To include the thermostat in a Z-Wave network, place the controller in the inclusion mode (see the instructions of your controller) and apply power to the electrical network to which the device is connected. The device will be added automatically (NWI). If this does not happen automatically, briefly press the system button three times on the top cover of the device. +If there are problems with connecting the device to your Z-Wave network, you must complete the Z-Wave network exclusion procedure, and then repeat the inclusion procedure. + To exclude the thermostat from the Z-Wave network, place the controller in the exclusion mode (see the controller instruction) and press the system button three times briefly. +Please note that after excluding the device from the Z-Wave network, all settings you have made will be reset to the factory settings. + To perform factory reset exclude the device form Z-Wave network and include it again. + + Initial configuration definition of CH-201 + Setpoint feature fixed for CH-201 + + + + + + +Relay mode. +Normal: Close the relay when the thermostat is in the "heating" mode and open when the set temperature is reached (Default). The most frequently used mode is used when the heater is directly connected through a thermostat. +Reverse: Open the relay when the thermostat is in the "heating" mode, close - when the set temperature is reached. Can be used with a limited list of special equipment (normally closed valves, etc.). + + + + + + +Set temperature threshold +To maintain the temperature, two values ​​are used: minimum and maximum. When the minimum value is reached, the heating will be turned on, when heating to the maximum value - the heating element will be turned off. For the convenience of the user, the controller assumes temperature adjustment with only one value, from which the thermostat will calculate the previously mentioned "minimum" and "maximum" values ​​of the temperature range. We recommend using a small range of 1 degree for more comfort and the most accurate match to the chosen temperature. If your heating element consumes a significant amount of energy at the moment of switching on, then it is recommended to reduce the number of on-off cycles by increasing this parameter. With our thermostat, you can always achieve the optimum operating mode by experiment or by contacting our specialists for help. The acceptable value is from 1 to 7 degrees: + + + + +Set point mode. +0 Switch on the heating mode at set point, switch off at set point + Δt +1 Switch on the heating mode at set point - Δt, switch off at set point +2 Switching on the heating mode at set point - ½ Δt, switching off at set point - ½ Δt (Default) + + + + + + + Operating mode in case a thermostat doesn't receive data from a temp sensor + + + + + Max time of data expectation from room temperature sensor + + + Set minimum allowable temperature + + + Set minimum allowable temperature + + + Set maximum alowable temperature + + + Set time turbo mode + + + Set power on turbo mode + + + Set temperature sensor mode + + + + + + Set polling period of the room sensor + + + The value that temprature should be changed to send data + + + Set Interval for forced sending data + + + Set Type of switch 1 (thermostat operating mode) + + + + + + + Set type of switch 2 (turbo mode) + + + + + + + Adjust temperature sensor if required. + + + + + + + + + + + + + + + + + + 2 + 0 + + + + + + + + + + + + diff --git a/openzwave/cooper/RF9501.xml b/openzwave/cooper/RF9501.xml new file mode 100644 index 00000000..3bfa0d08 --- /dev/null +++ b/openzwave/cooper/RF9501.xml @@ -0,0 +1,60 @@ + + + http://www.openzwave.com/device-database/001A:0000:534C + images/cooper/RF9501.png + https://products.z-wavealliance.org/products/740/ + RF9501 + U.S. / Canada / Mexico + ASPIRE RF 15A Wireless Switch + The ASPIRE RF 15A switch (RF9501) replaces regular switches or dimmers (where a neutral is present) to provide local and remote ON/OFF control for Incandescent, Magnetic Low-Voltage, Electronic Low-Voltage and Fluorescent lighting loads. Each switch can be manually controlled and remotely controlled by commands sent from an ASPIRE RF controller or other Z-Wave compatible controllers or programs. An ASPIRE RF switch utilizes existing 120V/AC, 60Hz standard house wiring and fits in a standard wallbox. No new wiring is needed. + http://www.cooperindustries.com/content/public/en/wiring_devices/products/lighting_controls/aspire_rf_wireless/switches/aspire_rf_15a_wireless_switch_rf9501.html + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/740/xml + + + + + + + The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + The amount of time in seconds the switch will turn on for when panic mode is trigered. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + The amount of time in seconds the switch will turn off for when panic mode is triggered. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation + + + + + Power up state of the device + + + + + + + + Enables this switch to participate in panic mode + + + + + + + + + + + + + diff --git a/openzwave/cooper/RF9505-T.xml b/openzwave/cooper/RF9505-T.xml new file mode 100644 index 00000000..d7633799 --- /dev/null +++ b/openzwave/cooper/RF9505-T.xml @@ -0,0 +1,49 @@ + + + http://www.openzwave.com/device-database/001A:0000:5244 + images/cooper/RF9505-T.png + https://products.z-wavealliance.org/products/741/ + RFTR9505-T + U.S. / Canada / Mexico + ASPIRE RF TR receptacle version complies with 2011 NEC section 406.12 specification that states all receptacles installed in dwelling units must be tamper resistant. The ASPIRE RF 15A Split Receptacle replaces regular receptacles and provides local and remote wireless ON/OFF control of a single outlet. Receptacle can be manually controlled and remotely controlled by commands sent from an ASPIRE RF controller (RFHDCSG, RFTDCSG) or other Z-Wave compatible controllers or programs. An ASPIRE RF receptacle utilizes existing 120V/AC, 60Hz standard house wiring and fits in a standard wallbox. No new wiring is required. + ASPIRE RF Tamper Resistant Receptacle + http://www.cooperindustries.com/content/public/en/wiring_devices/products/lighting_controls/aspire_rf_wireless/aspire_rf_15a_tamper_resistant_split_control_duplex_receptacle_rftr9505_t.html + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/741/xml + + + + + + + The amount of time in seconds the switch will turn on for when panic mode is trigered. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + The amount of time in seconds the switch will turn off for when panic mode is triggered. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + Power up state of the device + + + + + + + + Enables this device to participate in panic mode + + + + + + + + + + + + diff --git a/openzwave/cooper/RF9505-T.xml.zip b/openzwave/cooper/RF9505-T.xml.zip new file mode 100644 index 00000000..b81a0c8f Binary files /dev/null and b/openzwave/cooper/RF9505-T.xml.zip differ diff --git a/openzwave/cooper/RF9517.xml b/openzwave/cooper/RF9517.xml new file mode 100644 index 00000000..9a83ea43 --- /dev/null +++ b/openzwave/cooper/RF9517.xml @@ -0,0 +1,34 @@ + + + http://www.openzwave.com/device-database/001A:0000:5352 + images/cooper/RF9517.png + https://products.z-wavealliance.org/products/742/ + U.S. / Canada / Mexico + RF9517 + ASPIRE RF Accessory Switch + ASPIRE RF Accessory Switch (RF9517) replaces regular switches or dimmers to provide local and remote ON/OFF control. The device also provides 3-way, multi-location or virtual 3-way remote ON/OFF control of a selected RF switch without the need for traditional 3-way wiring. Each switch can be manually controlled and remotely controlled by commands sent from an ASPIRE RF controller or other Z-Wave compatible controllers or programs. ASPIRE RF switches utilize existing 120V/AC, 60Hz standard house wiring and fit in standard wallboxes. No new wiring is required. + http://www.cooperindustries.com/content/public/en/wiring_devices/products/lighting_controls/aspire_rf_wireless/switches/aspire_rf_accessory_switch_rf9517.html + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/742/xml + + + + + + + The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation + + + + + + + + + + diff --git a/openzwave/cooper/RF9540-N.xml b/openzwave/cooper/RF9540-N.xml new file mode 100644 index 00000000..91c0de1d --- /dev/null +++ b/openzwave/cooper/RF9540-N.xml @@ -0,0 +1,81 @@ + + + http://www.openzwave.com/device-database/001A:0101:4449 + images/cooper/RF9540-N.png + https://products.z-wavealliance.org/products/797/ + Cooper RF9540-N + RF9540-N + U.S. / Canada / Mexico + Aspire RF All load smart dimmer master + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/797/xml + Remove group 255 as 0 associations is reported from the device + + + + + + + The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + The amount of time in seconds the switch will turn on for when panic mode is trigered. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + The amount of time in seconds the switch will turn off for when panic mode is triggered. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation + + + + + Power up state of the device + + + + + + + + Enables this switch to participate in panic mode + + + + + + + The amount of time in seconds the switch will take to reach the desired dim level. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + Ensures that LED / CFL bulbs turn on when the preset dim level is low. Enabling this feature may cause the lights brightness to momentarily be bright when the switch is turned on before reducing in brightness to desired level + + + + + + + The minimum dim level the switch will allow. The minimum level must always be at least 13 below the maximum level. + + + + + The maximum dim level the switch will allow. The maximum level must always be at least 13 above the minimum level. + + + + + + + + + + diff --git a/openzwave/cooper/RF9542-Z.xml b/openzwave/cooper/RF9542-Z.xml new file mode 100644 index 00000000..c0c263ff --- /dev/null +++ b/openzwave/cooper/RF9542-Z.xml @@ -0,0 +1,55 @@ + + + http://www.openzwave.com/device-database/001A:0000:4441 + images/cooper/RF9542-Z.png + https://products.z-wavealliance.org/products/971/ + U.S. / Canada / Mexico + RF9542-Z + Aspire RF™ Accessory Dimmers replace regular switches or dimmers to provide local and remote ON/OFF/DIM/BRIGHT control. The device also provides multi-location control or virtual 3-way remote ON/OFF/DIM/BRIGHT control without the need for traditional 3-way wiring or a dedicated traveler wire. Aspire RF Accessory Dimmers provide other programmable functions (scenes, events, association, child lockout, etc.) when used with Aspire RF or other Z-Wave® compliant controller*. Each dimmer can be manually controlled and remotely controlled by commands sent from an Aspire RF controller (RFHDCSG, RFTDCSG, RFBER) or other Z-Wave compatible controllers or programs. Aspire RF Dimmers utilize existing 120V/AC 60Hz standard house wiring and fit in standard wallboxes. No new wiring is needed. + Dimmer Accessory Switch + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/745/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/971/xml + + http://www.cooperindustries.com/content/public/en/wiring_devices/products/lighting_controls/aspire_rf_wireless/dimmers/aspire_rf_accessory_w_leds_rf9542_z_.html + + + + + + The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation + + + + + Power up state of the device + + + + + + + + Enables this switch to participate in panic mode + + + + + + + The amount of time in seconds the switch will take to reach the desired dim level. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex) + + + + + + + + + + diff --git a/openzwave/cooper/RFWC5.xml b/openzwave/cooper/RFWC5.xml new file mode 100644 index 00000000..13eb45eb --- /dev/null +++ b/openzwave/cooper/RFWC5.xml @@ -0,0 +1,45 @@ + + + + + + Value 0x00-0x63 or 0xFF is the level for all nodes listed in the Group 1 + + + Value 0x00-0x63 or 0xFF is the level for all nodes listed in the Group 2 + + + Value 0x00-0x63 or 0xFF is the level for all nodes listed in the Group 3 + + + Value 0x00-0x63 or 0xFF is the level for all nodes listed in the Group 1 + + + Value 0x00-0x63 or 0xFF is the level for all nodes listed in the Group 4 + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/cooper/rf9534.xml b/openzwave/cooper/rf9534.xml new file mode 100644 index 00000000..89a83564 --- /dev/null +++ b/openzwave/cooper/rf9534.xml @@ -0,0 +1,18 @@ + + + http://www.openzwave.com/device-database/001A:0002:4449 + images/cooper/rf9534.png + https://products.z-wavealliance.org/products/761/ + U.S. / Canada / Mexico + RF9536 + RF9536 - 1000W Incandescent Smart Dimmer ASPIRE RF Dimmers replace regular switches or dimmers to provide local and remote ON/OFF/DIM/BRIGHT control and are compatible with incandescent lighting loads. ASPIRE RF Dimmers provide other programmable functions (scenes, events, association, child lockout, etc.) when used with ASPIRE RF or other Z-Wave compliant controllers*. + +(*Note: some specific ASPIRE RF features may not be programmable) + ASPIRE RF 1000W Incandescent Smart Dimmer + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/760/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/761/xml + + + + diff --git a/openzwave/danfoss/living.xml b/openzwave/danfoss/living.xml new file mode 100644 index 00000000..421d856d --- /dev/null +++ b/openzwave/danfoss/living.xml @@ -0,0 +1,34 @@ + + + http://www.openzwave.com/device-database/0002:0001:8005 + images/danfoss/living.png + https://products.z-wavealliance.org/products/93/ + 014G0001 + Danfoss Living Connect + living connect is an electronic radiator thermostat for homes. Wireless temperature control – all around the house. + + +For total control of your indoor environment, living connect radiator thermostats work wirelessly with Danfoss Link, bringing you the highest performance in home heating control. living connect thermostats have all the smart features of the living eco model, plus they can be wirelessly controlled from a single Danfoss Link control screen centrally placed in the home. This means you can set all living connect thermostats at once, and heating can still be controlled room-by-room. A user-friendly interface with a colourful touchscreen make operating a Danfoss Link simple. It is one of the most immediate, most convenient and most cost-effective ways to improve your home's energy efficiency. +Product Name: living connect +Brand Name: Danfoss +Product Line: Radiator Thermostat +Battery Type: AAA +Battery Count: 2 +Description: Radiator Thermostat +Inclusion Note: Short push middle button +Wakeup Note: Short push middle button + CEPT (Europe) + http://www.danfoss.com/businessareas/heating/products/literature/he/radiator-thermostats/radiator-sensors/living-by-danfoss/living-connect/b7bea5b9-eb96-45d5-b229-02739a4779c2.html + http://heating.danfoss.com/PCMPDF/Z_wave_living_connect_VDHMB202.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/93/xml + + + + + + 2 + 1 + + + diff --git a/openzwave/danfoss/rsroom.xml b/openzwave/danfoss/rsroom.xml new file mode 100644 index 00000000..a51e3968 --- /dev/null +++ b/openzwave/danfoss/rsroom.xml @@ -0,0 +1,95 @@ + + + http://www.openzwave.com/device-database/0002:8010:0003 + images/danfoss/rsroom.png + https://products.z-wavealliance.org/products/1188/ + CEPT (Europe) + 014G0159 + Devolo Z-Wave RS + Devolo RS 014G0159 Thermostat + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1062/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1063/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1187/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1188/xml + + + + + + + + + + 2 + 0 + + + + + + + Temperature Report threshold (1=0.1C) + + + + + Set-point display resolution (1=0.1C) + + + + + Min Set-point and override limit + + + + + Max Set-point and override limit + + + + + Setpoint control function + + + + + + + Temporarily override scheduler + + + + + + + Setpoint type in thermostat setpoint_reports + + + + + + + + Led on time (1=100ms) + + + + + Led Flash Period (0 to 65535 seconds) + + + + + Number of led flashes (duration) + + + + + Led Color + + + + + + diff --git a/openzwave/danfoss/z.xml b/openzwave/danfoss/z.xml new file mode 100644 index 00000000..c605adcb --- /dev/null +++ b/openzwave/danfoss/z.xml @@ -0,0 +1,36 @@ + + + http://www.openzwave.com/device-database/0002:0003:0005 + images/danfoss/z.png + https://products.z-wavealliance.org/products/932/ + http://heating.consumers.danfoss.com/xxTypex/585379.html + 014G0013 + CEPT (Europe) + Danfoss Living Connect Z v1.06 014G0013 + Electronic radiator thermostat + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/932/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/967/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1035/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1258/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1506/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1507/xml + + https://products.z-wavealliance.org/products/1507/ + 014G0013 + CEPT (Europe) + https://products.z-wavealliance.org/products/1506/ + CEPT (Europe) + 014G0801 + + + + + + + + 2 + 0 + + + diff --git a/openzwave/device_classes.xml b/openzwave/device_classes.xml new file mode 100644 index 00000000..e6985d1b --- /dev/null +++ b/openzwave/device_classes.xml @@ -0,0 +1,361 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/device_classes.xsd b/openzwave/device_classes.xsd new file mode 100644 index 00000000..50ba6274 --- /dev/null +++ b/openzwave/device_classes.xsd @@ -0,0 +1,75 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/device_configuration.xsd b/openzwave/device_configuration.xsd new file mode 100644 index 00000000..d850a24a --- /dev/null +++ b/openzwave/device_configuration.xsd @@ -0,0 +1,395 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/devolo/connectz.xml b/openzwave/devolo/connectz.xml new file mode 100644 index 00000000..7c9cb5ec --- /dev/null +++ b/openzwave/devolo/connectz.xml @@ -0,0 +1,15 @@ + + + + + + + + 2 + 0 + + + diff --git a/openzwave/devolo/mt02648.xml b/openzwave/devolo/mt02648.xml new file mode 100644 index 00000000..5c80e838 --- /dev/null +++ b/openzwave/devolo/mt02648.xml @@ -0,0 +1,135 @@ + + + http://www.openzwave.com/device-database/0175:000E:0002 + images/devolo/mt02648.png + https://products.z-wavealliance.org/products/1130/ + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To add into a Z-Wave network: +1. Have Z-Wave Controller entered inclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode. +3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds. + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To remove the device from a Z-Wave network: +1. Have Z-Wave Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. +Node ID has been excluded. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1130/Devolo home Control Door-Window.pdf + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +Press any key once, the device will awake 10 seconds. + Door/Window Contact + CEPT (Europe) + MT02648 + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To reset the device: +Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to factory default. + The Door/Window Contact MT02648 has door/window, temperature and illumination, 3 sensors function in one,based on Z-Wave technology. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1130/xml + + + + + + + Setting the BASIC command value to turn on the light. + 0 Send Basic Set Off. + 255 Send Basic Set On. + 1 to 99 Send Basic Set Level between 1 and 99. + + + + + Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower than + the threshold, the device will turn on the light. + 0 means turn off illumination detected function and never turn on the light. + 1 means darkest. + 99 means brightest. + 100 means turn off illumination detected function. And always turn on the light. + * Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. + + + + + 2 Bit Mask - When 1, Test Mode is Enabled, When 0, Test Mode is Disabled. + 4 Bit Mask - When 1, Door/Window function is Disabled, When 0, Door/Window function is Enabled. + 8 Bit Mask - When 1, Temperature Scale is Celsius, When 0, Temperature Scale is Fahrenheit. + 16 Bit Mask - When 1, Illumination Report after event trigger is not sent, When 0, illumination report after trigger is sent. + 32 Bit Mask - When 1, Temperature report after trigger is not sent, When 0, temperature report after trigger is sent. + 64 Reserved. + 128 Bit Mask - When 1, Back key release into test mode is disabled, when 0, back key into test mode is enabled. + + + + + 0 to 1 Bit Mask, When 1, Door opening will not send a signal to the nodes in association group 2, When 0, door opening will cause the lights in association group 2 to be sent a control signal. + 2 to 15 Reserved. + 16 Bit Mask, When 1, Disable the 5 second delay before turning off the light when the door is closed, When 0, enable a 5 second delay before turning off the light when the door is closed. + 32 Bit Mask, When 1, the automatic turn-off of the light after the light is turned on by a door opening, When 0, the light that is turned on by the door opening will be automatically turned off. + 64 to 255 Reserved. + + + + + 0 to 7 Reserved. + 8 Bit Mask, When 1, BASIC SET OFF is not sent when the door is closed, When 0, BASIC SET OFF is sent when the door is closed. + 16 Bit Mask, When 1, Door Opening is reported using Sensor Binary, When 0, Door Opening is reported using Notification Report. + 32 Bit Mask, When 1, Multi CC is Disabled, When 0, Multi CC is Enabled. + 64 Bit Mask, When 1, the battery state is not sent when the device is triggered, when 0, the battery state is sent when the device is triggered. + 255 Reserved. + + + + + After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. + 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. + + + + + The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function. + + + + + The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the "Temperature Report" section. + + + + + The illumination differential to report.0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the "Illumination Report" section. + + + + + + + + + + + diff --git a/openzwave/devolo/mt02755.xml b/openzwave/devolo/mt02755.xml new file mode 100644 index 00000000..4fd2679c --- /dev/null +++ b/openzwave/devolo/mt02755.xml @@ -0,0 +1,114 @@ + + + http://www.openzwave.com/device-database/0175:0020:0002 + images/devolo/mt02755.png + https://products.z-wavealliance.org/products/2226/ + 1. Have Z-Wave™ Controller entered inclusion mode. +2. Pressing the tamper key three times within 1.5 +seconds to enter the inclusion mode. +3. After add successful, the device will wake to +receive the setting command from Z-Wave™ +Controller about 20 seconds. + + MT02755 + Notice: Use this procedure only in the event +that the primary controller is lost or +otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds +and do not release the tamper key in the 4 th +pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that +within 2 seconds, release the tamper key. If +successful, the LED will light ON one second. +Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to +factory default. + MT02755 has temperature and humidity,based on Z-Wave™ technology. +It is the Z-Wave™ plus product, it support the security, OTA... Those newest features of the Z-Wave™ technology. Z-Wave™ is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. +This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the +network. + + When the device power on, the device will wake about 20 seconds. In +this duration, the controller can communicate with the device. Normally +the device is always sleeping to save the battery energy. + + 1. Have Z-Wave™ Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds +to enter the exclusion mode. +Node ID has been excluded. + + CEPT (Europe) + Humidity Sensor + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2226/MT02756_MT02755_Manual.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2226/xml + + + + + + + + + + + + + 16 Notification Type, 0:Using Notification Report. 16:Using Sensor Binary Report. + 32 Disable Multi CC in auto report. + + + + + The interval time for auto report the battery level. + 0 means turn off auto report. + The default value is 12. + The tick time can be set by the configuration No.20. + + + + + The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the humidity. 0 means turn off auto report humidity. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report each tick. + Setting this configuration will effect configuration No.10, No.13, No.14. + Units of one minute. + Caution1: Setting to 0 means turn off all auto report function. + Caution2: The value is unsigned byte + + + + + The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the "Temperature Report" section. + + + + + The humidity differential to report. 0 means turn off this function. The unit is %. + + + + + + + true + + + + + + + + + diff --git a/openzwave/devolo/mt02758.xml b/openzwave/devolo/mt02758.xml new file mode 100644 index 00000000..333f00ff --- /dev/null +++ b/openzwave/devolo/mt02758.xml @@ -0,0 +1,71 @@ + + + http://www.openzwave.com/device-database/0175:000A:0004 + images/devolo/mt02758.png + https://products.z-wavealliance.org/products/2308/ + 1. Have Z-Wave™ Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. +Node ID has been excluded. + Siren MT02758 is a wireless siren, based on Z-Wave™ technology. It is the Z-Wave™ plus product, it support the security, OTA... Those newest features of the Z-Wave™ technology. + Siren + CEPT (Europe) + MT02758 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2308/MT02758_manual.pdf + Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4 pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to factory default. + 1. Have Z-Wave™ Controller entered inclusion mode. +2. Pressing tamper key three times within 1.5 seconds +to enter the inclusion mode. +3. After add successful, the LED will light ON 1 second + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2308/xml + + + + + + + bit 0 Notification Type: 0: Using Notification Report, 1: Using Sensor Binary Report. + bit 7 Other sounds: 0: Disabled, 1: Enable. + + + + + + + + + Disable the alarm function. + 1: Disable Alarm, + 0: Enable Alarm. + Caution: After the power up, this configuration is always 0. + + + + + + + Play alarm sound duration, + 1 tick is 30 seconds. Default is 3 minutes, maximum is 63.5 minutes. + 0 means never auto stop. + + + + + + + true + + + + + + + + + diff --git a/openzwave/devolo/mt02792.xml b/openzwave/devolo/mt02792.xml new file mode 100644 index 00000000..9c36ee03 --- /dev/null +++ b/openzwave/devolo/mt02792.xml @@ -0,0 +1,76 @@ + + + + + + + + 0 Disable automatic interval meter reporting of Watts. + 1 to 32767 Enable automatic interval reporting with an interval of 5 * the value. + + + + + 0 Disable automatic interval meter kWh reporting. + If the setting is configured for 1hour (set value =6), the Home Control Metering Plug will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). + + + + + This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, Home Control Metering Plug will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300. + + + + + 0 Disable kWh Load Caution Reporting + 1 to 10000 Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh to 10000KWh. + + + + + Whenever the AC power return from lost, Home Control Metering Plug will restore the switch state which could be SWITCH OFF, LAST SWITCH STATE, SWITCH ON. The default setting is LAST SWITCH STATE. + + + + + + + + When the mode of switch On/Off is set to 0, any command of switch off will be disabled and the On/Off function of include button will be disabled. The default setting is enable mode. + + + + + + + LED indication mode + + + + + + + + 0 Disable the auto off function. + 1 to 32767 1s to 32767s for automatically turning off. + + + + + Whenever a switch off command,BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as a variety of 4 commands. + + + + + + + + + + + + + + diff --git a/openzwave/devolo/mt2646.xml b/openzwave/devolo/mt2646.xml new file mode 100644 index 00000000..6569d030 --- /dev/null +++ b/openzwave/devolo/mt2646.xml @@ -0,0 +1,100 @@ + + + http://www.openzwave.com/device-database/0175:0011:0001 + images/devolo/mt2646.png + https://products.z-wavealliance.org/products/1129/ + (Use this procedure only in the event that the primary controller is lost or otherwise inoperable.) + +1. Pressing On/Off button three times within 2 seconds will enter inclusion mode on the switch. +2. Within 1 second, press On/Off button again for 5 seconds. + + MT02646 + Metering Plug + This plug-in ON/OFF switch Home Control Metering Plug is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus™ enabled devices displaying the Z-Wave Plus™ logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-Wave™ enabled networks. Remote On/Off control of the connected load is possible with other manufacturer’s wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its +intended destination by routing the signal around obstacles and radio dead spots. Because Home Control Metering Plug supports Security Command Class, it can be added with a Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. +This plug-in ON/OFF switch is able to detect instance wattage (3000W/CE/CN,1500W/UL/TW/JP) and overload current (14.5A) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1129/PAN11-1B manual-20140816.pdf + 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing On/Off button three times within 2 seconds will enter inclusion + mode on the switch. + 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing On/Off button three times within 2 seconds will enter exclusion + mode on the switch. + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1129/xml + + + + + + + 0 Disable automatic interval meter reporting of Watts. + 1 to 32767 Enable automatic interval reporting with an interval of 5 * the value. + + + + + 0 Disable automatic interval meter kWh reporting. + If the setting is configured for 1hour (set value =6), the Home Control Metering Plug will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). + + + + + This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, Home Control Metering Plug will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300. + + + + + 0 Disable kWh Load Caution Reporting + 1 to 10000 Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh to 10000KWh. + + + + + Whenever the AC power return from lost, Home Control Metering Plug will restore the switch state which could be SWITCH OFF, LAST SWITCH STATE, SWITCH ON. The default setting is LAST SWITCH STATE. + + + + + + + + When the mode of switch On/Off is set to 0, any command of switch off will be disabled and the On/Off function of include button will be disabled. The default setting is enable mode. + + + + + + + LED indication mode + + + + + + + + 0 Disable the auto off function. + 1 to 32767 1s to 32767s for automatically turning off. + + + + + Whenever a switch off command,BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as a variety of 4 commands. + + + + + + + + + + + + + + diff --git a/openzwave/devolo/mt2647.xml b/openzwave/devolo/mt2647.xml new file mode 100644 index 00000000..ebc7e9ab --- /dev/null +++ b/openzwave/devolo/mt2647.xml @@ -0,0 +1,150 @@ + + + http://www.openzwave.com/device-database/0175:000D:0002 + images/devolo/mt2647.png + https://products.z-wavealliance.org/products/1131/ + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To add into a Z-Wave network: +1. Have Z-Wave Controller entered inclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode. +3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds. + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To remove the device from a Z-Wave network: +1. Have Z-Wave Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. +Node ID has been excluded. + Motion Sensor + CEPT (Europe) + MT02647 + The Motion Sensor MT02647 has PIR, temperature and illumination, 3 sensors function in one,based on Z-Wave technology. + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To reset the device: +Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to factory default. + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +Press any key once, the device will awake 10 seconds. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1131/Devolo home Control Motion.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1131/xml + + + + + + + + + + PIR sensitivity settings. + 0 means disable the PIR motion. + 1 means the lowest sensitivity, + 99 means the highest sensitivity. + High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency. + + + + + Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower than + the threshold, the device will turn on the light. + 0 means turn off illumination detected function and never turn on the light. + 1 means darkest. + 99 means brightest. + 100 means turn off illumination detected function. And always turn on the light. + * Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. + + + + + Bit 0: Reserve. + Bit 1: 1 means enable test mode, 0 means disable normal mode. Notice: This bit only effect by the DIP Switch setting to program mode. + Bit 2: Set to 1. + Bit 3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius. + Bit 4: Disable the illumination report after event triggered (1: Disable, 0: Enable). + Bit 5: Disable the temperature report after event triggered (1: Disable, 0: Enable). + Bit 6: Reserve. + Bit 7: Disable the back key release into test mode (1: Disable, 0: Enable). + ozw Recommended: 12 + + + + + Bit 0: Reserve, set to 1. + Bit 1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable). + Bit 2: Reserve, set to 1. + Bit 3: Reserve. + Bit 4: Reserve. + Bit 5: Reserve. + Bit 6: Reserve. + Bit 7: Reserve. + + + + + Bit 0: Reserve. + Bit 1: Enable sending motion OFF report (0:Disable, 1:Enable). + Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00. + Bit 2: Enable PIR super sensitivity mode (0:Disable, 1:Enable). + Bit 3: Reserve. + Bit 4: Notification Type (0: Notification Report, 1: Sensor Binary Report). + Bit 5: Disable Multi CC in auto report (1:Disable, 0:Enable). + Bit 6: Disable to report battery state when the device triggered (1:Disable, 0:Enable) + Bit 7: Reserve. + ozw Recommended: 22 + + + + + In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds). + Setting the suitable value to prevent received the trigger signal too frequency. Also can save the battery energy. + Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not start detecting. + + + + + After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. + 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. + + + + + The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function. + + + + + The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the "Temperature Report" section. + + + + + The illumination differential to report.0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the "Illumination Report" section. + + + + + + + + + + + diff --git a/openzwave/devolo/mt2651.xml b/openzwave/devolo/mt2651.xml new file mode 100644 index 00000000..4d6611ae --- /dev/null +++ b/openzwave/devolo/mt2651.xml @@ -0,0 +1,18 @@ + + + + + + false + + + + + + + + + diff --git a/openzwave/devolo/mt2652.xml b/openzwave/devolo/mt2652.xml new file mode 100644 index 00000000..d72ac6b0 --- /dev/null +++ b/openzwave/devolo/mt2652.xml @@ -0,0 +1,115 @@ + + + http://www.openzwave.com/device-database/0175:0101:0100 + images/devolo/mt2652.png + https://products.z-wavealliance.org/products/1143/ + CEPT (Europe) + Use this procedure only if the primary controller is missing or otherwise inoperable. +(1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 3, (3) keep button 4 pushed for 4 seconds. + Re-Inclusion and Exclusion are performed by pushing button 1 in management mode. Pushing all four buttons for 5 sec. turns the device into management mode (indicated by blinking green LED). + MT2652 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1143/SceneSwitch_Manual.docx + (1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 2. + Place your primary controller in inclusion mode by following the manufacturer's instructions, then activate inclusion on the wall controller by pressing any one of the four buttons for one second. Inclusion mode is indicated by the red/green blinking of the LEDs until the timeout occurs after 10 seconds. + The MT2652 Scene Switch is a Z-Wave device that can both control other Z-Wave devices and activate scenes. Although it is controlling other devices, the Wall Controller cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration parameters: + +Control of groups of other Z-Wave devices using 'ON', 'OFF' and Dim commands. +Activation of predefined scenes in Gateways or other Z-Wave devices. +This device support secure communication when included by a controller that also supports secure communication. + Scene Switch + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1143/xml + + + + + + In separate mode button 1 works with group A, button 3 with groups C. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C. + + + + + + In separate mode button 2 works with control group B, button 4 with control group D. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button B/D are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D. + + + + + + This parameter defines the command to be sent to devices of control group A when the related button is pressed + + + + + + + + + + + This parameter defines the command to be sent to devices of control group B when the related button is pressed + + + + + + + + + + + This parameter defines the command to be sent to devices of control group C when the related button is pressed + + + + + + + + + + + This parameter defines the command to be sent to devices of control group D when the related button is pressed + + + + + + + + + + + + + + + + + + + + If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/devolo/mt2653.xml b/openzwave/devolo/mt2653.xml new file mode 100644 index 00000000..3d8b6346 --- /dev/null +++ b/openzwave/devolo/mt2653.xml @@ -0,0 +1,113 @@ + + + + + + In separate mode button 1 works with group A, button 3 with groups C. + Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. + In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C. + + + + + + + In separate mode button 2 works with group B, button 4 with groups D. + Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. + In pair button 2/4 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D. + + + + + + + This parameter defines the command to be sent to devices of control group A when the related button is pressed + + + + + + + + + + + + This parameter defines the command to be sent to devices of control group B when the related button is pressed + + + + + + + + + + + + This parameter defines the command to be sent to devices of control group C when the related button is pressed + + + + + + + + + + + + This parameter defines the command to be sent to devices of control group D when the related button is pressed + + + + + + + + + + + + Send the following Switch All ON/OFF commands + + + + + + Invert meaning of On/Dim up and Off/Dim down in pairs of buttons. This applies only to pairs in grouped mode. Buttons 1 and 2 will become Off/Dim down, buttons 3 and 4 On/Dim up. + + + + + If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery + + + + + + + + + + + + + + false + + + + + + + + + + + + + diff --git a/openzwave/devolo/mt2756.xml b/openzwave/devolo/mt2756.xml new file mode 100644 index 00000000..095ef9ba --- /dev/null +++ b/openzwave/devolo/mt2756.xml @@ -0,0 +1,117 @@ + + + http://www.openzwave.com/device-database/0175:0021:0002 + images/devolo/mt2756.png + https://products.z-wavealliance.org/products/2227/ + 1. Have Z-Wave™ Controller entered inclusion mode. +2. Pressing the tamper key three times within 1.5 +seconds to enter the inclusion mode. +3. After add successful, the device will wake to +receive the setting command from Z-Wave™ +Controller about 20 seconds. + + MT02756 has temperature and humidity,based on Z-Wave™ technology. +It is the Z-Wave™ plus product, it support the security, OTA... Those newest features of the Z-Wave™ technology. Z-Wave™ is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. +This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the +network. + + When the device power on, the device will wake about 20 seconds. In +this duration, the controller can communicate with the device. Normally +the device is always sleeping to save the battery energy. + + Flood Sensor + MT02756 + CEPT (Europe) + 1. Have Z-Wave™ Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds +to enter the exclusion mode. +Node ID has been excluded. + + Notice: Use this procedure only in the event +that the primary controller is lost or +otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds +and do not release the tamper key in the 4 th +pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that +within 2 seconds, release the tamper key. If +successful, the LED will light ON one second. +Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to +factory default. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2227/MT02756_MT02755_Manual.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2227/xml + + + + + + + + Setting the BASIC command value. + When the flood trigger off(0x00), send the BASIC CC to the group 2 + + + + + Setting the BASIC command value. + When the flood trigger on(0xFF), send the BASIC CC to the group 2 + + + + + + + + + + 8 Disable send out BASIC OFF after the flood event cleared. + 16 Notification Type, 0:Using Notification Report. 16:Using Sensor Binary Report. + 32 Disable Multi CC in auto report. + 64 Disable to report battery state when the device triggered. + + + + + The interval time for auto report the battery level. + 0 means turn off auto report. + The default value is 12. + The tick time can be set by the configuration No.20. + + + + + The interval time for auto report the flood state. + 0 means turn off auto report. + The default value is 12. + The tick time can be set by the configuration No.20. + + + + + The interval time for auto report each tick. + Setting this configuration will effect configuration No.10, No.13, No.14 and No.15. + Units of one minute. + Caution1: Setting to 0 means turn off all auto report function. + Caution2: The value is unsigned byte + + + + + + + true + + + + + + + + + + diff --git a/openzwave/devolo/mt2759.xml b/openzwave/devolo/mt2759.xml new file mode 100644 index 00000000..5fa7a790 --- /dev/null +++ b/openzwave/devolo/mt2759.xml @@ -0,0 +1,169 @@ + + + http://www.openzwave.com/device-database/0175:0052:0002 + images/devolo/mt2759.png + https://products.z-wavealliance.org/products/2645/ + REMOVAL FROM A ZWAVE NETWORK (Z-WAVE EXCLUSION) + +1. Connect the device to the power supply +2. Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion +3. Enable add/remove mode on your Z-Wave gateway (hub) +4. Toggle the switch connected to the I1 terminal 3 times within 5 seconds +OR +If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2 and 6 seconds +5. The device will be removed from your network but any custom configuration parameters will not be erased + + FACTORY RESET + +1. Connect the device to the power supply +2. Within the first minute (60 seconds) the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 5 seconds (5 times change switch state) +OR +If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds + +*By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted. Use this reset procedure only when the main gateway (hub) is missing or otherwise inoperable. + + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2645/Manual_Devolo_HCswitch_FM.pdf + MT2759 + Home Control Switch FM + CEPT (Europe) + AUTOMATICALLY ADDING THE DEVICE TO A Z-WAVE NETWORK (AUTO INCLUSION) + +1. Enable add/remove mode on your Z-Wave gateway (hub) +2. Connect the device to the power supply (with the temperature sensor already connected – sold separately*). +3. Auto-inclusion will be initiated within 5 seconds of connection to the power supply and the device will automatically enrol in your network + +MANUALLY ADDING THE DEVICE TO A Z-WAVE NETWORK (MANUAL INCLUSION) + +1. Enable add/remove mode on your Z-Wave gateway (hub) +2. Connect the device to the power supply (with the temperature sensor already connected*) +3. Toggle the switch connected to the I1 terminal 3 times within 5 seconds +OR +If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2 and 6 seconds +4. A new multi-channel device will appear on your dashboard +*If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor. + + +*Make sure the device is excluded from your network before connecting the temperature sensor. Switch off the power supply, connect the temperature sensor, and re-include the device to your network. + + The Switch FM controls on/off function for one electrical device. It measures power consumption of the connected device, and can be paired with a digital temperature sensor (sold separately). It supports push-button/momentary switches and toggle switches (default). + +The connection of a digital temperature sensor means you can create complex scenes and control any device relative to a set temperature range. The Devolo Switch FM also acts as a Z-Wave repeater to improve the range and stability of the Z-Wave network. + + Initial Version - Copied from qubino/ZMNHADx.xml + + + + + + + + + + + + + + + + + + + + + + Switch FM module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + 0 => Auto OFF disabled. 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). Auto OFF enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 + + + 0 - Auto OFF disabled. 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). Auto ON enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 + + + + + + + + + + + + + Set value from 0 - 100 (0%- 100%). 0 = Reporting Disabled. 1 - 100 = 1% - 100% and reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 10% + + + Set value means time interval (0 - 32535) in seconds, when power report is send. 0 = Reporting Disabled. 1 - 32535 = 1 second - 32535 seconds and reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Set value is added or subtracted to actual measured value by sensor. Available configuration parameters : default value 32536. 32536 offset is 0.0C. From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters : 0 = reporting disabled. 1 to 127 = 0,1C to 12,7C, step is 0,1C. Default value is 5 = 0,5C + + + + + + false + + + + + + + + + + + + + + + + + true + + + + + + + + + + false + + + diff --git a/openzwave/devolo/mt2760.xml b/openzwave/devolo/mt2760.xml new file mode 100644 index 00000000..3649edaa --- /dev/null +++ b/openzwave/devolo/mt2760.xml @@ -0,0 +1,218 @@ + + + http://www.openzwave.com/device-database/0175:0051:0001 + images/devolo/mt2760.png + https://products.z-wavealliance.org/products/2838/ + • Connect module to power supply +• bring module within maximum 1 meter (3feet) of the main controller, +• enable add/remove mode on main controller, +• press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. +By this function all parameters of the module are set to default values and own ID is deleted. +If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values. +NOTE: If the module is included with parameters 100 or 101 with values different to default and module reset is done, wait at least 30s before next inclusion + + This Z-Wave module is used for dimming the bulb or to manage the speed of a fan. The module can be controlled either through a Z-Wave network or through the wall switch. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of bulb or fan and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network. + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2838/manualdevoloHCdimmerFM25012018_0910.pdf + CEPT (Europe) / Australia / New Zealand + • Connect module to power supply (with +temperature sensor connected - if purchased), +• enable add/remove mode on main controller +• auto-inclusion (works for about 2 minutes after connected to power supply) or +• press push button I1 three times within 3s (3 times change switch state within 3 seconds) or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 2 second. +NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply. +NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module. + + MT2760 + Home Control Dimmer FM + • press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. + +Please use reset procedure only when the network primary controller is missing or otherwise inoperable. + + Initial Version - Copied from qubino/ZMNHDDx.xml + + + + + + + + + + + + + + + + + + + + + + Default value 0 + + + + + Flush dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + Default value 255. + + + + + + + 0 - Auto OFF disabled. + 1 second to 32536 seconds Auto OFF enabled with defined time, step is 1 second. + Default value 0. + + + 0 - Auto ON disabled. + 1 second to 32535 seconds Auto ON enabled with defined time, step is 1 second. + Default value 0. + + + Dimming is done by push button or switch connected to I1 (by default). + Enabling 3-way switch, dimming can be controlled by push button or switch connected to I1 and I2. + Default value 0. + + + + + + + If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value. + Default value 0. + + + + + Default value 0. + + + + + Set value from 0 - 100 (0% - 100%). + 0 - Reporting Disabled. + 1 - 100 = 1% - 100% Reporting enabled. + Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. + Default value 5. + + + Set value means time interval (0 - 32767) in seconds, when power report is send. + 0 - Reporting Disabled. + 1 second to 32767 seconds reporting enabled. + Power report is send with time interval set by entered value. + Default value 300 (power report in Watts is send each 300s). + + + 1 - 98 = 1% - 98%, step is 1%. Minimum dimming values is set by entered value. + Default value 1 (Minimum dimming value is 1%). + + + 2 - 99 = 2% - 99%, step is 1%. Maximum dimming values is set by entered value. + Default value 99 (Maximum dimming value is 99%). + + + Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through. + 1- 255 = 10mseconds - 2550mseconds (2,55s), step is 10mseconds. + Default value 100 (Dimming time between min. and max. dimming values is 1s). + + + Time of moving the Dimmer between min. and max dimming values by continues hold of push button I1. + 1- 255 = 1 second - 255 seconds. + Default value 3 (Dimming time between min. and max. dimming values is 3s). + + + This parameter is used with association group 4. + A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. + A receiving device MUST ignore the start level if the Ignore Start Level bit is 1. + Default value 0. + + + + + This parameter is used with association group 3. + The Duration field MUST specify the time that the transition should take from the current value to the new target value. + A supporting device SHOULD respect the specified Duration value. + Default value 0. + + + + + Enabling I2 means that Endpoint (I2) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + Endpoint device type selection: notification sensor (1 - 6) sensor binary (9). + NOTE: After parameter change, module has to be re included into the network in order setting to take effect! + Default value 1. + + + + + + + + + + + Enabling I3 means that Endpoint (I3) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + Endpoint device type selection: notification sensor (1 - 6) sensor binary (9). + NOTE: After parameter change, module has to be re included into the network in order setting to take effect! + Default value 1. + + + + + + + + + + + Set value is added or subtracted to actual measured value by sensor. + 32536 : offset is 0.0C. + From 1 to 100 : value from 0.1 C to 10.0 C is added to actual measured temperature. + From 1001 to 1100 : value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + Default value 32536. + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. + 0 : Reporting disabled. + 1- 127 = 0,1C - 12,7C, step is 0,1C. + Default value 5 = 0,5C change. + + + + + + + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/devolo/mt2761.xml b/openzwave/devolo/mt2761.xml new file mode 100644 index 00000000..5c765db3 --- /dev/null +++ b/openzwave/devolo/mt2761.xml @@ -0,0 +1,154 @@ + + + http://www.openzwave.com/device-database/0175:0052:0003 + images/devolo/mt2761.png + https://products.z-wavealliance.org/products/2962/ + • Connect module to power supply (with +temperature sensor connected - if purchased), +• auto-inclusion (works for about 5 seconds after connected to power supply) or +• press push button I1 three times within 3s (3 times change switch state within 3 seconds) or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 2 second. + +NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply. + +NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module. + + • Connect module to power supply +• bring module within maximum 1 meter (3 feet) of the main controller, +• enable add/remove mode on main controller, +• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. +By this function all parameters of the module are set to default values and own ID is deleted. + +If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values. + +NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + +NOTE: If the module is included with parameters 71 with value different to default and module reset is done, wait at least 30s before next inclusion + + • press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. + +NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + This Z-Wave module is used to control the motor of blinds, rollers, shades, venetian blinds, etc … The module can be controlled either through a Z-Wave network or through the wall switch. Precise positioning is supported for motors equipped with mechanical or electronic end switches. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of motor and support connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-Wave network. + + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2962/Manual_Devolo_HC Shutter_FM.pdf + MT2761 + Home Control Shutter FM + CEPT (Europe) / Australia / New Zealand / U.S. / Canada / Mexico + + Initial Version - Copied from qubino/ZMNHCDx.xml + + + + + + Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 1 + + + Set value means time interval (0 - 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) + + + This parameter defines selection between two available operating modes + + + + + + This parameter defines the time necessary for slats to make full turn (180 degrees) + default value 150 = 1,5 seconds + 0 - Tilting time disabled + 1 - 32767 = 0,01seconds - 327,67 seconds + + + + This parameter defines slats position after up/down movement through Z-wave or push-buttons + Slats return to previously set position only in case of + + + + + + This parameter defines shutter motor moving time of complete opening or complete closing. + Default value 0 + 0 - moving time disabled (working with limit switches). + 1 - 65535 = 0,1seconds - 6553,5seconds + After that time motor is stopped (relay goes to off state) + + + + Power threshold to be interpreted when motor reach the limit switch. + default value 10 = 10W + 0 - 127 = 1-127 W. The value 0 means reaching a limit switch will not be detected. + + + + By modifying the parameters setting from 0 to 1 a Shutter enters the calibration mode + + + + + + This parameter defines the max time before motor power consumption is read after one of the relays is switched ON. + If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, motor in end position) the relay will switch OFF. + Time is defined by entering it manually. + default value 0 = time is set automatically + 3 - 50 = 0,3seconds - 5seconds (100ms resolution) + + + + + This parameter defines the minimum time delay between next motor movement (minimum time between switching motor off and on again). + default value 5 = 500ms + 1 - 30 = 0,1seconds - 3seconds (100ms resolution) + + + + + Set value is added or subtracted to actual measured value by sensor. + default value 32536 + 32536 - offset is 0.0C + From 1 to 100 - value from 0.1 C to 10.0 C is added to actual measured temperature. + From 1001 to 1100 - value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter + default value 5 = 0,5C + 0 - Reporting disabled + 1-127 = 0,1C - 12,7C, step is 0,1C + + + + + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/devolo/rs014G0159.xml b/openzwave/devolo/rs014G0159.xml new file mode 100644 index 00000000..7b4086d5 --- /dev/null +++ b/openzwave/devolo/rs014G0159.xml @@ -0,0 +1,84 @@ + + + + + + + + + + 2 + 0 + + + + + + + Temperature Report threshold (1=0.1C) + + + + + Set-point display resolution (1=0.1C) + + + + + Min Set-point and override limit + + + + + Max Set-point and override limit + + + + + Setpoint control function + + + + + + + Temporarily override scheduler + + + + + + + Setpoint type in thermostat setpoint_reports + + + + + + + + Led on time (1=100ms) + + + + + Led Flash Period (0 to 65535 seconds) + + + + + Number of led flashes (duration) + + + + + Led Color + + + + + + diff --git a/openzwave/diehlcontrols/766366.xml b/openzwave/diehlcontrols/766366.xml new file mode 100644 index 00000000..b9ae31c7 --- /dev/null +++ b/openzwave/diehlcontrols/766366.xml @@ -0,0 +1,15 @@ + + + http://www.openzwave.com/device-database/0103:0002:0002 + images/diehlcontrols/766366.png + https://products.z-wavealliance.org/products/1208/ + DiehlControls Dimmer Actuator + Dimmer Actuator + CEPT (Europe) + 766366 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/996/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1208/xml + + + diff --git a/openzwave/dlink/dch-z110.xml b/openzwave/dlink/dch-z110.xml new file mode 100644 index 00000000..a9b427d1 --- /dev/null +++ b/openzwave/dlink/dch-z110.xml @@ -0,0 +1,139 @@ + + + http://www.openzwave.com/device-database/0108:000E:0002 + images/dlink/dch-z110.png + https://products.z-wavealliance.org/products/1151/ + CEPT (Europe) + D-Link Z-Wave Door/Window Sensor + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +Press any key once, the device will awake 10 seconds. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1151/D-Link DCH-Z110_120 manual.pdf + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To remove the device from a Z-Wave network: +1. Have Z-Wave Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. +Node ID has been excluded. + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To add into a Z-Wave network: +1. Have Z-Wave Controller entered inclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode. +3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds. + DCH-Z110 + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To reset the device: +Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to factory default. + The mydlink Z-Wave Door/Window Sensor DCH-Z110 has door/window, temperature and illumination, 3 sensors function in one,based on Z-Wave technology. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1151/xml + + + + + + + Setting the BASIC command value to turn on the light. The 0xFF (-1) means turn on the light. + For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. + + + + + Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower than + the threshold, the device will turn on the light. + 0 means turn off illumination detected function and never turn on the light. + 1 means darkest. + 99 means brightest. + 100 means turn off illumination detected function. And always turn on the light. + * Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. + + + + + Bit 0: Reserved + Bit 1: Reserved + Bit 2: Disable the door/window function (1: Disable, 0: Enable). + Bit 3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius. + Bit 4: Disable the illumination report after event triggered (1: Disable, 0: Enable). + Bit 5: Disable the temperature report after event triggered (1: Disable, 0: Enable). + + + + + Multi-Sensor Function switch. Using bit to control. + Bit 0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2 (1: Disable, 0: Enable). + Bit 1: Reserved always 1 + Bit 2: Reserved always 1 + Bit 3: Reserved + Bit 4: Disable delay 5 seconds to turn off the light, when door/window closed. + Bit 5: Disable auto turn off the light, after door/window opened to turn on the light. Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless. + Bit 6: Enable temperature monitoring. When this bit enabled the temperature changed 3 degree Fahrenheit. It will report. And also temp above 140 it will report every 64 seconds. + + + + + Customer function switch, using bit control. + Bit 0: Reserve. + Bit 1: Enable sending motion OFF report. Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00. + Bit 2: Enable PIR super sensitivity mode. + Bit 3: Enable don't send out BASIC OFF after door closed. + Bit 4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. + Bit 5: Disable Multi CC in auto report. + Bit 6: Disable to report battery state when the device triggered. + Bit 7: Reserve. + + + + + After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. + 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. + + + + + The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function. + + + + + The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the "Temperature Report" section. + + + + + The illumination differential to report.0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the "Illumination Report" section. + + + + + + + + + + + + + + diff --git a/openzwave/dlink/dch-z120.xml b/openzwave/dlink/dch-z120.xml new file mode 100644 index 00000000..304bff45 --- /dev/null +++ b/openzwave/dlink/dch-z120.xml @@ -0,0 +1,153 @@ + + + http://www.openzwave.com/device-database/0108:000D:0002 + images/dlink/dch-z120.png + https://products.z-wavealliance.org/products/1152/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1152/D-Link DCH-Z110_120 manual.pdf + CEPT (Europe) + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +Press any key once, the device will awake 10 seconds. + The mydlink Z-Wave Motion Sensor DCH-Z120 has PIR, temperature and illumination, 3 sensors function in one,based on Z-Wave technology. + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To add into a Z-Wave network: +1. Have Z-Wave Controller entered inclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode. +3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds. + DCH-Z120 + D-Link Z-Wave Motion Sensor + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To reset the device: +Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to factory default. + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To remove the device from a Z-Wave network: +1. Have Z-Wave Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. +Node ID has been excluded. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1152/xml + + + + + + + Set the BASIC command value to turn on the light. + 255: always turn on the light. + For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. + + + + + PIR sensitivity settings. + 0 means disable the PIR motion. + 1 means the lowest sensitivity. + 99 means the highest sensitivity. + High sensitivity means the sensor can detect over a long distance, but if there is more noise signal in the environment, it will re-trigger too frequently. + + + + + Set the illumination threshold to turn on the light. When the event is triggered and the environment illumination is lower than the threshold, the device will turn on the light. + 0 means turn off illumination detected function and never turn on the light. + 1 means darkest. + 99 means brightest. + 100 means turn off illumination detected function. And always turn on the light. + * Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. + + + + + Bit 0: Reserved + Bit 1: 1 means test mode, 0 means normal mode. + Notice: This bit only effect by the DIP Switch setting to customer mode, otherwise it decides by DIP Switch setting to Test or Normal Mode. + Bit 2: Reserved + Bit 3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius. + Bit 4: Disable the illumination report after event triggered (1: Disable, 0: Enable). + Bit 5: Disable the temperature report after event triggered (1: Disable, 0: Enable). + Bit 6: Reserved. + Bit 7: Disable the back key release into test mode. (1: Disable, 0: Enable) + Note: All default to 0. + + + + + Multi-Sensor Function switch. Using bit to control. + Bit 0: Reserved. (Default: 0) + Bit 1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) (Default: 0) + Bit 2: Reserved always 1 + Bit 3: Reserved always 0 + Bit 4: Reserved always 0 + Bit 5: Reserved always 0 + Bit 6: Reserved always 0 + Bit 7: Reserved always 0 + + + + + Customer function switch, using bit control. + Bit 0: Reserved always 0. + Bit 1: Enable sending motion OFF report. Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00. (Default: 0) + Bit 2: Enable PIR super sensitivity mode. (Default: 1) + Bit 3: Reserved always 0 + Bit 4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. (Default: 0) + Bit 5: Disable Multi CC in auto report. (Default: 0) + Bit 6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) (Default: 0) + Bit 7: Reserved always 0. + + + + + In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds). Set a suitable value to prevent receiving the trigger signal too frequently. Also can save the battery energy. Notice: If this value bigger than the configuration setting NO. 9 there will be a period after the light turned off where the PIR is not detecting. + + + + + After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. + 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. + + + + + The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can be set by the configuration No.20. + + + + + The interval time for auto reporting of the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can be set by the configuration No.20. + + + + + The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can be set by the configuration No.20. + + + + + The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function. Default is 30 minutes + + + + + The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the "Temperature Report" section. + + + + + The illumination differential to report.0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the "Illumination Report" section. + + + + + + + + + + + + + + diff --git a/openzwave/dlink/dch-z210.xml b/openzwave/dlink/dch-z210.xml new file mode 100644 index 00000000..26fe6150 --- /dev/null +++ b/openzwave/dlink/dch-z210.xml @@ -0,0 +1,37 @@ + + + This plug-in ON/OFF switch DCH-210 (aka Wenzhou TKB TZ88) is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus™ enabled devices displaying the Z-Wave Plus™ logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-Wave™ enabled networks. Remote On/Off control of the connected load is possible with other manufacturer’s wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because TZ88 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. +This plug-in ON/OFF switch is able to detect instance wattage (3000W/CE/CN, 1500W/UL/TW/JP) and overload current (14.5A) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status. + + Smart Energy Plug In Switch + DCH-Z210 + CEPT (Europe) / U.S. / Canada / Mexico + images/dlink/dch-z210.png + + Initial version - clone of Wenzhou (TKB) TZ88 + Add Product Pic + + + Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing On/Off button three times within 2 seconds will enter inclusion mode. +2. Within 1 second, press On/Off button again for 5 seconds until LED is off. +3. IDs are excluded. + 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing On/Off button three times within 2 seconds will enter inclusion mode. + CEPT (Europe) + 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. +2.Pressing On/Off button three times within 2 seconds will enter exclusion mode. +3. Node ID has been excluded. + DCH-Z10 + + + + + + If the setting is configured for 1 hour (value=720), the plug will report its instant power consumption every 1 hour. + + + If the setting is configured for 1 hour (value=6), the plug will report its accumulated power consumption (kWh) every 1 hour. + + + diff --git a/openzwave/dlink/dch-z510.xml b/openzwave/dlink/dch-z510.xml new file mode 100644 index 00000000..062bca6e --- /dev/null +++ b/openzwave/dlink/dch-z510.xml @@ -0,0 +1,66 @@ + + + http://www.openzwave.com/device-database/0108:000A:0004 + images/dlink/dch-z510.png + https://products.z-wavealliance.org/products/1262/ + CEPT (Europe) + 1. Have Z-Wave™ Controller entered inclusion mode. +2. Pressing tamper key three times within 1.5 seconds +to enter the inclusion mode. +3. After add successful, the LED will light ON 1 second + mydlink Z-Wave Siren + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1262/DCH-Z510_Manual.pdf + The DCH-Z510 mydlink ™ Z-Wave ™ Siren is a wireless siren, based on Z-Wave ™ technology. It is the Z-Wave™ plus product, it supports the security, OTA... Those newest features of the Z-Wave™ technology. Z-Wave™ is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home lectronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. + DCH-Z510 + Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4 pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to factory default. + 1. Have Z-Wave™ Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. +Node ID has been excluded. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1262/xml + + + + + + + Bit 0: Reserved + Bit 1: Reserved + Bit 2: Reserved + Bit 3: Reserved + Bit 4: Notification type (0: Using Notification Report, 1: Using sensor Binary Report). + Bit 5: Reserved + Bit 6: Reserved + Bit 7: Reserved + + + + + Disable the alarm function. + 0: Enable Alarm, 1:Disable Alarm, + Caution: After the power up, this configuration always be 0. + + + + + + + Play alarm sound duration. + 1 tick is 30 second. Default is 3 minutes, maximum is 63.5 minutes. + 0: means never auto stop + + + + + + + + + + + + + diff --git a/openzwave/dome/0002.xml b/openzwave/dome/0002.xml new file mode 100644 index 00000000..c7f6c4ab --- /dev/null +++ b/openzwave/dome/0002.xml @@ -0,0 +1,43 @@ + + + http://www.openzwave.com/device-database/021F:0002:0003 + images/dome/0002.png + https://products.z-wavealliance.org/products/2158/ + Press and hold the open/close button for at least 10 seconds then release. The Shut-Off’s memory will be erased to factory settings. A flashing light indicates a successful factory reset. Beware that resetting your device will disconnect it from your system. Only do this if the controller is missing or otherwise unreachable! + The Dome™ Home Automation DMWV1 Water Main Shut-off is designed to fit over existing ¼ turn ball-valves for pipes sized up to 1½ inch. No professional plumbing contractor is required- it can be installed by a homeowner with just a screwdriver. This device requires a Z-Wave Certified hub for operation. When configured with a Water Leak Sensor, the Water Main Shut-off can automatically cut off the supply to limit the damage. You can also remotely control the valve position using your smarthome system mobile app. Extra-long Z-Wave wireless range (up to 150 ft) allows you to place it where it’s needed without worrying if the signal is reaching your Z-Wave Hub. Also functions as Z-Wave signal extender. Dome™ DMWV1 Water Main Shut-off comes with a 1-year limited warranty. Measurements in inches: 2.5 x 3.5 x 6. Dome™ Home Automation Z-Wave devices give your family peace of mind and security you can count on. With Dome™, you’re always connected and always covered. + +• Installs over existing valve without need of a plumber using just a screw driver. Works with ¼ turn ball-valves on pipes sized up to 1½ inch +• Open/Close valve control allowing for automatic water shut-off when leaks are detected as well as on demand control using your smarthome mobile app. +• Up to 150-foot range. Functions as Z-Wave signal extender +• Z-Wave Plus Certified. Requires a Z-Wave Certified Hub to operate + + DMWV1 + 1. Follow the instructions for your Z-Wave certified Controller to enter exclusion mode. +2. When prompted, press the “open/close” button on the Shut-Off quickly 3 times in a row. + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2158/Dome Water Main Shut-Off Advanced Manual.pdf + 1 For proper inclusion, bring the Water Main Shut-Off to the final location where it will be used. * +2 Follow the instructions for your Z-Wave controller to enter inclusion mode. +3 Make sure the Water Main Shut-Off is powered on, and when prompted by your controller, press the “open/close” button quickly 3 times in a row. The LED will stop blinking and stay on continuously upon successful inclusion. + +*For non Z-Wave Plus networks, please consult the owner’s manual for your primary controller to determine the best method and location for adding the Water Main Shut-Off to your Z-Wave network. + Water Main Shut-Off + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2158/xml + + + + + + + + + + + + + diff --git a/openzwave/dome/0083.xml b/openzwave/dome/0083.xml new file mode 100644 index 00000000..04e441b6 --- /dev/null +++ b/openzwave/dome/0083.xml @@ -0,0 +1,86 @@ + + + + + + + + This parameter sets the sensitivity of the Motion Detector. + It is a unitless parameter ranging in values from 8 up to 255, with 8 being the highest sensitivity level and 255 being the lowest. + After physical installation, make sure the farthest part of the coverage area is still visible to the Motion Detector by adjusting this parameter. + + + + + This parameters sets the amount of time after a motion event before the Motion Detector reports no activity to the main controller. + This also sets the amount of time before a BASIC_SET(00) command is sent to Association Group 2 to turn off any activated devices. + This value must be higher than the value of Parameter 6, and if this parameter is reset to default settings, Parameter 6 will also be reset. + See Group 2 on page for more information. + + + + + This parameter sets the value sent by the BASIC_SET command to Association Group 2. + 0 Turn Off Device. + 1 to 99 Set Device to Value. + 255 Turn On Device. + + + + + This setting enables or disables motion detection and light reporting. + + + + + + + If Parameter 8 is enabled, this setting sets the light level below which the Motion Detector will send BASIC_SET commands to Association Group 2 when motion is detected. + + + + + After each motion event, the Motion Detector is disabled for the amount of time set by this parameter before it can send out another Motion Detected Notification Report/Binary Sensor Report. + This value must be lower than the value of Parameter 2, and if this parameter is reset to default settings, Parameter 2 will also be reset. + + + + + This parameter sets the amount of time between each successive ambient light level reading that is sent. + This value must be less than the Wakeup Interval Time (which is 43,200 seconds or 12 hours by default.) + + + + + If this parameter is enabled, the Motion Detector will only send Basic Set commands to Associon Group 2 if the ambient light level is below the value set in Parameter 05. + + + + + + + This Parameter sets the minimum change in ambient light level (in lux) the Motion Detector must detect before a Multilevel Sensor Report is sent to the main controller. + + + + + If this parameter is enabled, the LED INDICATOR will flash everytime there motion is detected. + If this is disabled, the LED INDICATOR will not flash to indicate motion events. + + + + + + + + + + + + + + + diff --git a/openzwave/dome/0085.xml b/openzwave/dome/0085.xml new file mode 100644 index 00000000..374aa499 --- /dev/null +++ b/openzwave/dome/0085.xml @@ -0,0 +1,97 @@ + + + http://www.openzwave.com/device-database/021F:0085:0003 + images/dome/0085.png + https://products.z-wavealliance.org/products/1954/ + If needed, the Flood Sensor can be reset locally by following these steps. Only do this when your Z-Wave controller is disconnected or otherwise unreachable. Beware that resetting your device will disconnect it from the system: +1. Remove the MAIN BODY COVER and confirm that your Flood Sensor is powered up. +2. Press and hold the CONNECT BUTTON for at least 10 seconds then release. A flashing light indicates a successful factory reset. +3. The Flood Sensor’s memory will be erased to factory settings. + Follow the instructions for your Z-Wave Certified Conto enter inclusion mode. When prompted by the controller: +1. The Flood Sensor should be within 10’ of your Z-Wave controller for the inclusion process. After successful pairing, the device can be brought to the desired location. +2. Remove the MAIN BODY COVER by twisting it apart counter-clockwise. +3. Remove the BATTERY TAB. +4. Press the BUTTON quickly 3 times in a row. +The INDICATOR LED will flash five times indicating inclusion. + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1954/Dome Leak Sensor API Manual.pdf + Dome Z-Wave Plus Leak Sensor + Because the Flood Sensor is a battery powered device, it wakes up on regular intervals to give battery and other status updates to the controller, as well as to accept configuration settings from the controller. This helps to extend the battery life. The device can be forced to wake up to submit these reports or accept new settings immediately by simply pressing and holding the BUTTON for two seconds. The LED INDICATOR will flash once indicating successful wake up. + The Dome™ Home Automation DMWS1 Leak Sensor is purpose built to withstand a wet environment it may find itself in. It is suitable for areas where leaks are likely to occur: sinks, toilets, washing machines and water heaters. The Leak Sensor’s flat design allows it to be easily slid under common household appliances with low clearance from the floor. Additional flexibility is provided with a Remote Sensor extending 4 feet for placing it in hard to reach areas and sump pump pits. Once the leak is detected, the Leak Sensor will alert you by beeping locally and it will send an instant notification to your smarthome system. With a Z-Wave Certified Hub, this sensor can be set up to trigger sirens, lights and custom automation scenes or even turn off the water when used with Dome™ Water Main Shut Off (DMWV1). Extra-long Z-Wave wireless range (up to 150 ft) allows you to place it where it’s needed without worrying if the signal is reaching your Z-Wave Hub. There is a 3-year battery life, so you can always be confident that your sensor has power. Dome™ DMWS1 Leak Sensor comes with a 1-year limited warranty. Measurements in inches: 2.625 x 2.625 x 1.125. Dome™ Home Automation Z-Wave devices give your family peace of mind and security you can count on. With Dome™, you’re always connected and always covered. +• Water resistant design with ultra low profile to fit under appliances. Includes a 4 feet long Remote Probe for hard to reach areas and sump pump pits +• Local alarm sound with LED visual indicator when leaks are detected. Can be integrated with sirens, lights and compatible water main shut off valves (like Dome™ DMWV1) +• Up to 150-foot range and 3-year battery life (CR14250 Battery Included) +• Z-Wave Plus Certified. Requires a Z-Wave Certified Hub to operate +• Tested to work with SmartThings, Vera, Staples Connect, HomeSeer, Nexia, Piper, URC, Harmony. Not supported by Wink, DSC, ADT Pulse, 2Gig, Napco, Interlogix, Honeywell (Dome™ is not associated with listed brands) + + DMWS1 + Follow the instructions for your Z-Wave Certified Conto enter exclusion mode. When prompted by the controller: +1. Remove the MAIN BODY COVER from the MAIN BODY BASE. +2. Press the CONNECT BUTTON quickly 3 times in a row. +The INDICATOR LED will flash five times indicating exclusion/disconnection. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1954/xml + + + + + + + + This parameter sets the total amount of time the Leak Sensor will beep and light its LED in the event of a leak. + 0 Leak Sensor beeps until water is removed. + 1 to 255 in Minutes. + + + + + This parameter defines the amount of time the Leak Sensor remains quiet between each Reminder Alarm. + + + + + This parameter sets the amount of time the Leak Sensor beeps before it is muted. + + + + + This parameter sets the length of each beep after the Initial Alarm. + + + + + This parameter enables or disables the audible alarm (beeping) functionality of the Leak Sensor. + + + + + + + This parameter enables or disables the Leak Sensor. + If disabled, the device will not respond in any way to detected leaks. + + + + + + + This parameter defines the value sent by the BASIC_SET command to Association Group 2. + 0 Turn Off Device. + 1 to 99 Set Device to Value. + 255 Turn On Device. + + + + + + + + + + + + + diff --git a/openzwave/dome/0086.xml b/openzwave/dome/0086.xml new file mode 100644 index 00000000..775bcfb5 --- /dev/null +++ b/openzwave/dome/0086.xml @@ -0,0 +1,95 @@ + + + http://www.openzwave.com/device-database/021F:0086:0003 + images/dome/0086.png + https://products.z-wavealliance.org/products/1847/ + The Dome™ Home Automation DMMZ1 Mouser is a powerful rodent electric trap with Z-Wave technology built-in. It kills mice, rats and other rodents quickly, cleanly and humanely with a powerful jolt of electricity. Simply set bait, turn on and place in desired location. When connected to Z-Wave Certified Hub, once the trap is full, it sends out a notification to your smarthome system. You can easily dispose of Mouser’s contents without ever having to touch them. Use the top handle and tip to dispose of caught rodents. Specially designed removable and washable bait tray will allow you to easily replace the bait and set it back up. It operates on 4 AA batteries (not included) and is optimised to last over 50 uses. Mouser features extra-long Z-Wave wireless range (up to 150 ft) and Dome™ DMMZ1 Mouser comes with a 1-year limited warranty. Measurements in inches: 8.75 x 4.5 x 5. Dome™ Home Automation Z-Wave devices give your family peace of mind and security you can count on. With Dome™, you’re always connected and always covered. +• Humanely kills mice, rats and other rodents with a powerful electric shock and sends an alert to your smarthome system when the trap needs to be emptied +• Easy to use: set bait, turn on and place in desired location +Touch free: hold handle and tip to dispose of contents, then set it again +• Up to 150-foot Z-Wave range. Operating Temperature: 32°F - 112°F. Powered by 4 AA batteries (not included) enabling it to be triggered over 50 times +• Z-Wave Plus Certified. Works as a stand alone electronic mouse trap but requires a Z-Wave Certified Hub for notification functionality +• Tested to work with SmartThings, Vera, Staples Connect, HomeSeer, Nexia, Piper, URC, Harmony. Not supported by Wink, DSC, ADT Pulse, 2Gig, Napco, Interlogix, Honeywell (Dome is not associated with listed brands) + + Follow the instructions for your Z-Wave Certified controller to enter inclusion mode. When prompted by the controller: +1. Bring the Mouser to within 10’ of your Z-Wave controller for the inclusion process. After successful pairing, the device can be brought to the desired location. +2. Remove top cover by sliding it back and lifting up. +3. Insert batteries. +4. Press the CONNECT BUTTON quickly 3 times in a row. +5. The LED INDICATOR will flash five times indicating inclusion + + If needed, the Mouser can be reset locally by following these steps. Only do this when your Z-Wave controller is disconnected or otherwise unreachable. Beware that resetting your device will disconnect it from the system: +1. Remove the TOP COVER and confirm that your Mouser is powered up. +2. Press and hold the CONNECT BUTTON for at least 10 seconds then release. A flashing LED INDICATOR indicates a successful factory reset. +3. The Mouser’s memory will be erased to factory settings. + + DMMZ1 + If needed, the Mouser can be reset locally by following these steps. Only do this when your Z-Wave controller is disconnected or otherwise unreachable. Beware that resetting your device will disconnect it from the system: +1. Remove the TOP COVER and confirm that your Mouser is powered up. +2. Press and hold the CONNECT BUTTON for at least 10 seconds then release. A flashing LED INDICATOR indicates a successful factory reset. +3. The Mouser’s memory will be erased to factory settings. + U.S. / Canada / Mexico + Follow the instructions for your Z-Wave Certified controller to enter exclusion mode. +When prompted by the controller: +1. Remove top cover by sliding it back and lifting up. +2. Press the CONNECT BUTTON quickly 3 times in a row. +The LED INDICATOR will flash five times indicating exclusion/disconnection. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1847/Mouser API Manual.pdf + Dome Mouser + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1847/xml + + + + + + + + This parameter defines the value sent by the BASIC_SET command to Association Group 2. + 0 Turn Off Device. + 1 to 99 Set Device to Value. + 255 Turn On Device. + + + + + This parameter sets firing mode of the Mouser. + Two firing modes are available: in the first (Continuous Fire,) electricity is passed continuously for the entire duration, + and in the second (Burst Fire,) electricity is passed continuously only for the first minute and it is pulsed at approximately 400 beats per minute for the remainder of the time. + + + + + + + This parameter defines how long the Mouser will fire continuously before it starts to burst-fire + + + + + This parameter enables or disables the indicator LED alarm when the trap is tripped. + + + + + + + This parameter sets the amount of time the LED Indicator blinks after the trap is tripped. + 0 LED Blinks Until Trap is Reset. + 1 to 255 in Hours. + + + + + + + + + + + + + diff --git a/openzwave/dome/0087.xml b/openzwave/dome/0087.xml new file mode 100644 index 00000000..470eb64e --- /dev/null +++ b/openzwave/dome/0087.xml @@ -0,0 +1,81 @@ + + + + + + + + This parameter enables/disables the METER_REPORT function, which sends periodic reports to Group1 members with information on line voltage, current load, and power and energy consumption. + Also see Param 2 and 6. + + + + + + This parameter sets the amount of time between each successive METER_REPORT signal sent to Group 1 (also see Param 1 and 6.) + + + + Sets the maximum current the plug will pass before it cuts off power and sends a NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED signal to Group 1 and a BASIC_SET(FF) to Group 2. + The LED will then blink red once per second until the notification is cleared after the current returns to normal. + To clear the NOTIFICATION and start monitoring again, the BUTTON must be pushed once (only after the current is back to normal) or a BINARY_SWITCH_SET(FF) command must be sent. + NOTE: this value must be higher than Param 4. + + + + + Sets the current level at which the On/Off Plug-In Switch will flash its LED yellow, until the current returns to below this level. + It will NOT cut off current to the device; this functions as a visible warning to the user. + NOTE: this value must be lower than Param 3. + + + + This parameter enables or disables the indicator LED. + + + + + + In addition to sending a METER_REPORT to Group 1 in the time interval set by Param 2, the On/Off Plug-In Switch also sends a METER_REPORT when it detects a relative change in current flow. + This parameter sets this minimum current change amount, in percent, at which point the On/Off Plug-In Switch will send a METER_REPORT to Group 1. + Also see Param 1 and 2. + + + + + This parameter sets whether or not the On/Off Plug-In Switch will remember if it was turned on or off when it was last plugged in. + If enabled, whenever the device is rebooted (plugged in and out of the main outlet,) it will resume its state from before the reboot. + If disabled, it will turn on every time the device is rebooted. + + + + + + If this parameter is enabled, whenever the On/Off Plug-In Switch is turned on, it will automatically turn off after a set amount of time (set in Param 9.) + + + + + + Sets the time interval before the On/Off Plug-In Switch automatically shuts off. + See Param 8. + + + + If this parameter is enabled, the user can turn the device on or off using the BUTTON. + + + + + + + + + + + + + diff --git a/openzwave/dome/0088.xml b/openzwave/dome/0088.xml new file mode 100644 index 00000000..b72ca595 --- /dev/null +++ b/openzwave/dome/0088.xml @@ -0,0 +1,117 @@ + + + http://www.openzwave.com/device-database/021F:0088:0003 + images/dome/0088.png + https://products.z-wavealliance.org/products/2059/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2059/Dome Siren Manual.pdf + The Dome™ Home Automation DMS01 Siren offers ten user selectable sounds with three volume levels (at up to 105dB) and adjustable siren timeout (30/60/300 seconds or infinite). It includes a functionality of an alarm siren, doorbell and an audible chime notification when door/window opens (advanced settings subject to Z-Wave Hub compatibility). Additional visual notification is provided by built-in flashing LED’s when triggered. One of a kind device on the market with 100% battery operation allowing for easy installation anywhere in your home. There is a 3-year battery life, so you can always be confident that your siren has power. Extra-long Z-Wave wireless range (up to 150 ft) allows you to place it where it’s needed without worrying if the signal is reaching your Z-Wave Hub. Dome™ DMS01 Siren comes with a 1-year limited warranty. Measurements in inches: 2.625 x 2.625 x 1.125. Dome™ Home Automation Z-Wave devices give your family peace of mind and security you can count on. With Dome™, you’re always connected and always covered. + Follow the instructions for your Z-Wave certified Controller to enter exclusion mode. +When prompted by the Controller: +1. Remove the Back Plate of the Siren. +2. Press the Connect Button quickly 3 times in a row. +The LED Ring will flash five times indicating exclusion/disconnection. + U.S. / Canada / Mexico + Follow the instructions for your Z-Wave certified Controller to enter inclusion mode. +When prompted by the Controller: +1. For proper inclusion, bring the Siren to the final location where it will be used. * +2. Remove the Back Plate of the Siren. +3. Remove the Battery Tabs. +4. Press the Connect Button quickly 3 times in a row. +The LED Ring will flash five times indicating inclusion. +*For non Z-Wave Plus networks, please consult the owner’s manual for your primary controller to determine the best method and location for adding the Siren to your Z-Wave network. + Dome Z-Wave Plus Siren + To disconnect from the Z-Wave Network and restore factory default settings: +1. Open the Back Plate and make sure the Siren is powered. +1. Hold the Connect Button for 10 seconds until the LED Ring blinks once, then release the button. +Only do this if the controller is missing or otherwise unreachable! + DMS01 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2059/xml + + + + + + + This parameter sets the volume of the Siren (primary) sound. There are three possible volume levels available. + + + + + + This parameter defines the length of the Alarm/primary notification. + + + + + + + This parameter defines the number of times the Chime/Secondary Notification will play. + + + This parameter sets the volume of the Chime (secondary) sound. There are three possible volume levels available. + + + + + + + The Siren offers ten different sounds to use as the Siren (primary) notification. + This parameter sets the Siren (primary) notification sound. + + + + + + + + + + + + + + + If Parameter 7 is set to 02, the Siren will play a secondary chime sound instead of the main alarm. + The Siren offers ten different sounds to use as the Chime (secondary) notification. + This parameter sets the Chime (secondary) notification sound. + + + + + + + + + + + + + + This Parameter toggles between the Primary and Secondary notification sound to be played when the Siren receives a BINARY_SWITCH_SET(FF) command. + + + + + This Parameter enables or disables the Flashing LED Ring (strobe) accompanying the Primary Notification. + + + + + This Parameter enables or disables the Flashing LED Ring (strobe) accompanying the Secondary Notification. + + + + + + + + + + + + + diff --git a/openzwave/dome/0101.xml b/openzwave/dome/0101.xml new file mode 100644 index 00000000..1e88683f --- /dev/null +++ b/openzwave/dome/0101.xml @@ -0,0 +1,26 @@ + + + + + + + This parameter sets the delay time from when the Door/Window Sensor sends the BASIC_SET command to Association Group 2 and when the BASIC_SET(0) is sent.,It accepts a value up to 65,535, in seconds. + + + + This parameter sets the value sent by the BASIC_SET command to Association Group 2. + + + + + + + + + + + + diff --git a/openzwave/dome/0201.xml b/openzwave/dome/0201.xml new file mode 100644 index 00000000..e618f065 --- /dev/null +++ b/openzwave/dome/0201.xml @@ -0,0 +1,149 @@ + + + http://www.openzwave.com/device-database/021F:0201:0003 + images/dome/0201.png + https://products.z-wavealliance.org/products/2830/ + The Dome Door/Window Sensor Pro is a battery powered security-enabled* Z-Wave Plus magnetic reed switch that can monitor the status of doors, windows, and anything else that opens and closes. It can also report ambient temperature levels. The Door/Window Sensor consists of two parts - the “sensor,” and the “magnet.” The sensor has a “reed switch” inside, which is sensitive to the magnet’s presence when aligned properly and within the defined distance. When the sensor and magnet are brought together or pulled apart, the sensor will report its open/close status to its Z-Wave controller, and the encrypted wireless communication* ensures that user data remains secure. Because many manufacturers use Z-Wave to communicate, the Door/Window Sensor can interact with different products of different categories. + +• Z-Wave Plus Certified +• S0 Security-Enabled* +• Built-In Temperature Sensor +• Up to 250’ range +• Ten-Year Battery Life +• LED Signal Strength Indication +• 1.25” Max distance between sensor & magnet +• Ultra-Narrow (1/4”) Magnet for Placement Between Door and Casing +• Monitor doors, windows, medicine cabinets, drawers, garage doors, and many other openings + Because the Door/Window Sensor Pro is a battery powered device, it wakes up on regular intervals to give battery and other status updates to the controller, as well as to accept configuration settings from the controller. This helps to extend the battery life. The Sensor Cover holds down the Button when installed, and the device can be forced to wake up to submit reports or accept new settings immediately by simply removing the Sensor Cover and then replacing it after. If the device is already included in a system, the LED Indicator will flash Red until the cover is closed. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2830/Gen2DWAPIManualv1.2_1.pdf + Dome Door/Window Sensor Pro + If needed, the Door/Window Sensor Pro can be reset locally by following these steps. Only do this if your Z-Wave controller is missing or otherwise unreachable. Beware that resetting your device will disconnect it from the system: +1. Remove the Sensor Cover and confirm that your Door/Window Sensor Pro is powered up. +2. Wait for 5 seconds. +3. Move the Magnet and Sensor Base in and out of the closed position 6 times. +4. The LED Indicator will light up red for five seconds when reset successfully. + +The Door/Window Sensor Pro memory will be erased to factory settings. + + U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand + DMDP1 + Follow the instructions for your Z-Wave Certified Controller to enter exclusion mode. When prompted by the controller: +Remove the SENSOR COVER and the LED Indicator will start blinking red. +Press the Button quickly 3 times in a row. +The LED Indicator will flash green three times indicating exclusion/disconnection and will then continue flashing red (indicating tamper) until the cover is replaced. + New Installation +1. For proper inclusion, bring the Door/Window Sensor Pro to the final location where it will be used*. +2. Follow the instructions for your Z-Wave controller to enter inclusion mode. +3. Remove the Battery Tab protruding from the Battery Tab Slit. +4. The device will automatically enter inclusion mode for two minutes and the LED Indicator will alternate between green and red. + +Upon successful inclusion the LED Indicator will flash green three times then stop blinking. + +Re-Installation +1. For proper inclusion, bring the Door/Window Sensor Proto the final location where it will be used*. +2. Follow the instructions for your Z-Wave controller to enter inclusion mode. +3. Remove the Sensor Cover and the LED Indicator will start blinking yellow. +4. Press the Button quickly 3 times in a row. +5. The device will enter inclusion mode for two minutes and the LED Indicator will alternate between green and red. + +After successful inclusion, the LED Indicator will flash green three times then blink red until the cover is replaced. + +*For non Z-Wave Plus networks, please consult the owner’s manual for your primary controller to determine the best method and location for adding the Door/Window Sensor Pro to your Z-Wave network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2399/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2829/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2830/xml + + + + + + + + This parameter enables or disables the LED Indicator flashing to indicate opening and closing events. + The Door/Window Sensor will always flash the LED Indicator for inclusion, exclusion, tamper, and other system events. + + + + + + + This parameter switches the Notification or Binary Sensor report sent when the door opens or closes. + If this parameter is set to 01, the Door/Window Sensor will report closed instead of open when the Magnet and Sensor are pulled apart. + + + + + + + By default, the Door/Window Sensor uses the Notification command class to communicate open/close and tamper events. + If this Parameter is set to 1, the device will instead use the Binary Sensor command class. + + + + + + + + The Door/Window Sensor can also monitor and report ambient temperature conditions. + However, temperature sensing functionality is disabled by default to save battery life, and this configuration parameter is used to enable or disable this feature. + + + + + + + This Configuration Parameter can offset the temperature value reported by +/- 125 degrees to compensate for temperature variances in a room - for example, the temperature near the ceiling in a room is significantly higher than the average temperature of the same room. + This Parameter accepts a signed 8-bit value with an absolute value of up to 125, and its units are Dependant on Configuration Parameter 07. + Temperature Offset. + 0 to 125 : 0 to 125 degrees. + 255 to 130 : -1 to -125 degrees. + + + + The Door/Window Sensor can report temperature values in either Celsius or Fahrenheit, and this parameter allows the user to decide which unit is used. + + + + + + This parameter sets the value sent by the Basic Set command to Association Group 2 (for more information, see Association Group Info.). + 0 Turn Off Device. + 1 to 99 Set Device to Value. + 255 Turn On Device. + + + + + This parameter sets the value sent by the Basic Set command to Association Group 4. + The Door/Window Sensor sends a Basic Set command to Association Group 4 when the door or window opens (for more information, see Association Group Info.). + 0 Turn Off Device. + 1 to 99 Set Device to Value. + 255 Turn On Device. + + + + + This parameter sets the value sent by the Basic Set command to Association Group 4. + The Door/Window Sensor sends a Basic Set command to Association Group 4 when the door or window opens (for more information, see Association Group Info.). + 0 Turn Off Device. + 1 to 99 Set Device to Value. + 255 Turn On Device. + + + + + + + + + + + + + + diff --git a/openzwave/dome/dmex1.xml b/openzwave/dome/dmex1.xml new file mode 100644 index 00000000..b43773da --- /dev/null +++ b/openzwave/dome/dmex1.xml @@ -0,0 +1,49 @@ + + + images/dome/dmex1.png + https://products.z-wavealliance.org/products/2984/ + U.S. / Canada / Mexico + Turn the primary controller of Z-Wave network into inclusion mode, press the button on DMEX1 quickly 3 times in a row. + The Dome Range Extender is designed to improve communication between Z-Wave devices. It amplifies Z-Wave signals and increases the reach of your controller, ensuring your devices stay connected. The Extender has an LED light that works as a nightlight and can also act as an indicator in regular mode. The included suction cup lets you mount the Extender onto any smooth surface while using a micro USB power supply. All these features make the Dome Range extender the perfect choice for your home. + DMEX1 Range Extender + Press the button 6 times quickly, then immediately press and hold for 10 seconds. Use this procedure only in the event that your primary network controller is missing or inoperable. + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2984/DomeExtenderAPIManual10-31.pdf + DMEX1 + Turn the primary controller of Z-Wave network into inclusion mode, press the button on DMEX1 quickly 3 times in a row. + + Initial Entry + + + + + + false + + + + + + + This parameter sets the luminance (brightness) level at which night light is turned off. This is a unitless value that can be set to any value from 0 - 10, with a default value of 5. The higher this value, the brighter the ambient light must be to turn off the night light. + Range:0-10 + Default: 5 + + + + + This parameter sets the luminance (brightness) level at which night light is turned on. This is a unitless value that can be set to any value from 0 - 10, with a default value of 5. The lower this value, the dimmer the ambient light must be to turn on the night light. + Range:0-10 + Default: 5 + + + + + + + + + + + diff --git a/openzwave/domitech/zb22uk.xml b/openzwave/domitech/zb22uk.xml new file mode 100644 index 00000000..f1082ecd --- /dev/null +++ b/openzwave/domitech/zb22uk.xml @@ -0,0 +1,74 @@ + + + http://www.openzwave.com/device-database/020E:3135:4C42 + images/domitech/zb22uk.png + https://products.z-wavealliance.org/products/1543/ + ZB22UK + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1543/Instructions_ZB22UK_10222015 small.pdf + Smart LED light bulb with Z-Wave radio. +- Control lights remotely and save energy +- Compatible with smart home systems supporting Z-Wave +- 60 Watt equivalent light (806 lumens) +- Consumes only 9 watts of power +- 2700K Day light with frosted glass +- Instant ON and fully dimmable +- Functions as a Z-Wave signal repeater +- Very simple to include in your network +- Z-Wave Plus certified + + 1. Turn Off power to the light bulb socket +2. Screw in the light bulb +3. Place your network controller into inclusion mode by following the controller manufacturer's instructions +4. Turn On power to the light bulb. If successful, the LED light bulb will flash twice to indicate successful inclusion. +5. If the controller/gateway shows it was a fail, repeat the procedure. + +Note: If Inclusion still fails after the 2nd attempt, you need to first RESET the dt Smart Bulb before repeating the above steps. + + CEPT (Europe) + You may manually reset the light bulb as follows: +1. Flick the wall switch “OFF-ON” 4 times within 4 seconds. +2. The dt Smart Bulb will flash twice after Reset is successful. + +Use this procedure only in the event that the network primary controller is lost or otherwise inoperable. + 1. Turn off power to the light bulb socket +2. Follow the network controller instruction to place your network controller into exclusion mode to remove the dt light bulb from the network. +3. After being prompted by the network controller, turn On power to the light bulb. If successful, the LED light bulb will flash twice to indicate successful inclusion. + + + Smart LED Light Bulb + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1543/xml + + + + + + You may select the dim level whenever the light is turned back ON to be either full brightness (100% dim level) or be the same as the last dim setting when the light is ON by flicking the wall switch + + + + + + You may change the dimming step level when you adjust the brightness by your controller/gateway. + When the value is low, dimming/brightening is gradual. + When the value is high, dimming/brightening is rapid. + + + + + You may change the dimming speed quicker or slower. + When the value is low, the step timing is quick. + When the value is high, the step timing is slow. + + + + + + + + + + diff --git a/openzwave/domitech/ze27eu.xml b/openzwave/domitech/ze27eu.xml new file mode 100644 index 00000000..2d33033c --- /dev/null +++ b/openzwave/domitech/ze27eu.xml @@ -0,0 +1,72 @@ + + + http://www.openzwave.com/device-database/020E:3134:4C42 + images/domitech/ze27eu.png + https://products.z-wavealliance.org/products/1914/ + 1. Turn off power to the light bulb socket +2. Follow the network controller instruction to place your network controller into exclusion mode to remove the dt light bulb from the network. +3. After being prompted by the network controller, turn On power to the light bulb. If successful, the LED light bulb will flash twice to indicate successful exclusion. + + + CEPT (Europe) / U.S. / Canada / Mexico + You may manually reset the light bulb as follows: +1. Flick the wall switch “OFF-ON” 4 times within 4 seconds. +2. The dt Smart Bulb will flash twice after Reset is successful. + +Use this procedure only in the event that the network primary controller is lost or otherwise inoperable. + ZE26i + Smart LED light bulb with Z-Wave radio. +- Control lights remotely and save energy +- Compatible with smart home systems supporting Z-Wave +- 60 Watt equivalent light (750 lumens) +- Consumes only 9 watts of power +- 2700K soft light with frosted glass +- Instant ON and fully dimmable +- Functions as a Z-Wave signal repeater +- Very simple to include in your network +- Z-Wave Plus certified + + Smart LED Light Bulb + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1914/ZE26I Manual.pdf + 1. Turn Off power to the light bulb socket +2. Screw in the light bulb +3. Place your network controller into inclusion mode by following the controller manufacturer's instructions +4. Turn On power to the light bulb. If successful, the LED light bulb will flash twice to indicate successful inclusion. +5. If the controller/gateway shows it was a fail, repeat the procedure. + +Note: If Inclusion still fails after the 2nd attempt, you need to first RESET the dt Smart Bulb before repeating the above steps. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1530/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1914/xml + + + + + + You may select the dim level whenever the light is turned back ON to be either full brightness (100% dim level) or be the same as the last dim setting when the light is ON by flicking the wall switch + + + + + + You may change the dimming step level when you adjust the brightness by your controller/gateway. + When the value is low, dimming/brightening is gradual. + When the value is high, dimming/brightening is rapid. + + + + + You may change the dimming speed quicker or slower. + When the value is low, the step timing is quick. + When the value is high, the step timing is slow. + + + + + + + + + + diff --git a/openzwave/domux/DX1CA-Z.xml b/openzwave/domux/DX1CA-Z.xml new file mode 100644 index 00000000..60e9430b --- /dev/null +++ b/openzwave/domux/DX1CA-Z.xml @@ -0,0 +1,16 @@ + + + + + + + + + + + + + diff --git a/openzwave/domux/DX1CG-Z.xml b/openzwave/domux/DX1CG-Z.xml new file mode 100644 index 00000000..39dbbae2 --- /dev/null +++ b/openzwave/domux/DX1CG-Z.xml @@ -0,0 +1,15 @@ + + + + + + + + + + + + diff --git a/openzwave/domux/DX1DS-Z.xml b/openzwave/domux/DX1DS-Z.xml new file mode 100644 index 00000000..0c602706 --- /dev/null +++ b/openzwave/domux/DX1DS-Z.xml @@ -0,0 +1,18 @@ + + + + + + + + + + + + + + + diff --git a/openzwave/domux/DX1HT-Z.xml b/openzwave/domux/DX1HT-Z.xml new file mode 100644 index 00000000..ed34f0b5 --- /dev/null +++ b/openzwave/domux/DX1HT-Z.xml @@ -0,0 +1,16 @@ + + + + + + + + + + + + + diff --git a/openzwave/domux/DX1MS-Z.xml b/openzwave/domux/DX1MS-Z.xml new file mode 100644 index 00000000..bb04fe65 --- /dev/null +++ b/openzwave/domux/DX1MS-Z.xml @@ -0,0 +1,16 @@ + + + + + + + + + + + + + diff --git a/openzwave/domux/DX1SA-Z.xml b/openzwave/domux/DX1SA-Z.xml new file mode 100644 index 00000000..f19cd585 --- /dev/null +++ b/openzwave/domux/DX1SA-Z.xml @@ -0,0 +1,16 @@ + + + + + + + + + + + + + diff --git a/openzwave/domux/DX1WL-Z.xml b/openzwave/domux/DX1WL-Z.xml new file mode 100644 index 00000000..3e9aaf99 --- /dev/null +++ b/openzwave/domux/DX1WL-Z.xml @@ -0,0 +1,18 @@ + + + + + + + + + + + + + + + diff --git a/openzwave/domux/DX2SK-Z.xml b/openzwave/domux/DX2SK-Z.xml new file mode 100644 index 00000000..d1526e37 --- /dev/null +++ b/openzwave/domux/DX2SK-Z.xml @@ -0,0 +1,13 @@ + + + + + + + + + + + diff --git a/openzwave/dragontech/wd-100.xml b/openzwave/dragontech/wd-100.xml new file mode 100644 index 00000000..8cf39c0a --- /dev/null +++ b/openzwave/dragontech/wd-100.xml @@ -0,0 +1,61 @@ + + + http://www.openzwave.com/device-database/0184:3034:4447 + images/dragontech/wd-100.png + https://products.z-wavealliance.org/products/2031/ + 1. Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF. +2. Delete(Exclude) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. +3. Normally, the sequence is as follows: when the exclusion process is prompted by your primary controller, single click and release the rocker switch. The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. + WD-100 + In-Wall Dimmer Switch + 1. Turn the connected lights ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF. +2. Add(Include) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. +3. Normally, the sequence is as follows: when the inclusion process is prompted by your primary controller, single click and release the rocker switch to ON or OFF position. The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2031/WD-100_UG_updated 07212016.pdf + Please use this procedure only in the event that the network primary controller is lost or otherwise inoperable. + +All Configuration Parameters can all be restored to their factory default settings by using your primary controller to delete/reset the device. +To manually reset, tap the ON button twice quickly and then tap the OFF button twice quickly. Repeat the procedure to restore the settings to the factory default. + + + - Works with incandescent and dimmable florescent (CFL) or most LED lighting +- ON/OFF status and location LED indicator +- Fits into standard single or multiple gang junction box +- Keypad can be replaced manually to match color with other wall switches +- Over-The-Air firmware upgrade available with compatible gateway, Z-Wave static controller, or PC and software +- Internal resettable fuse to protect from surge current +- Manual reset capability +- Support Central Scene + + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1127/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1676/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2031/xml + + + + + + + The orientation of the ON/OFF on the rocker switch can be inverted by changing the configuration item from 0 to 1 + + + + + indicates the number of levels the lighting will change when the timer runs out + + + + + indicates the time duration of each level. The resolution is 10 milliseconds for example, a default value of 3 means the timer runs out every 30 milliseconds. + + + + + + + + + + diff --git a/openzwave/duco/DucoBox.xml b/openzwave/duco/DucoBox.xml new file mode 100644 index 00000000..9868e130 --- /dev/null +++ b/openzwave/duco/DucoBox.xml @@ -0,0 +1,127 @@ + + + + + DucoBox + The ducBox is a Z-wave controlled mechenical ventilation unit + http://www.openzwave.com/device-database/XXXX:XXXX:XXXX + https://www.duco.eu/nl-nl-gearchiveerde-systemen + https://www.duco.eu/nl-nl-gearchiveerde-systemen + images/DefaultProductImage.png + https://www.duco.eu/Wes/CDN/1/Attachments/GH_DucoTronic%20System%20Z-wave_(nl)_online%20garantie_LowRes_635500206155264045.pdf + + Press all 4 buttons to enter installer mode. Next pres button 1 to add the device to a z-wave network. + + Press all 4 buttons to enter installer mode. Next press and hold button 1 and 2 to remove the device from a z-wave network. + https://products.z-wavealliance.org/products/49 + CEPT (Europe) + 00001801/G12809 + + Created the config file from scratch based on information from https://products.z-wavealliance.org/products/49 and http://devel.pepper1.net/zwavedb/device/156 + Remove auto on group 1, cleanup MetaDataItem + + + + + + + + + + + + + + + + + + + + + + + + + How often the value is measured(example: if value=60, the sensor value is measured every 60 seconds) + + + + Set point CO2: Used in ‘automatic mode’. (button 4) if the device is a CO2 sensor. The CO2 level in a room is a good indication of the air quality in this room. + When the CO2 level is above this set point, the room needs more ventilation. Consequently, the CO2 sensor will open the associated grating unit. + + + + + Set point CO2: Used in ‘automatic mode’. (button 4) if the device is a CO2 sensor. The CO2 level in a room is a good indication of the air quality in this room. + When the CO2 level is above this set point, the room needs more ventilation. Consequently, the CO2 sensor will open the associated grating unit. + + + + + The value when button1 is pressed. Values above 99 will be capped to 99 (maximum) used in association group 1 + + + + + The value when button2 is pressed. Values above 99 will be capped to 99 (maximum) used in association group 1 + + + + + The value when button3 is pressed. Values above 99 will be capped to 99 (maximum) used in association group 1 + + + + + The minimum value that can be send by the CO2 sensor when it is in automatic mode. + + + + + Temperature high set point: used in association group 2 or 3 + + + + + Temperature low set point: used in association group 2 or 3 + + + + + Temperature delta set point: used in association group 4 + + + + + RH high set point: used in association group 5 or 6 + + + + + RH low set point: used in group5 or 6 + + + + + RH delta set point: used in group7 + + + + + CO2 high set point: not available in RH sensor + + + + + CO2 low set point: not available in RH sensor + + + + + CO2 delta set point: not available in RH sensor + + + + diff --git a/openzwave/duco/Ducotronic_CO-RH_sensor.xml b/openzwave/duco/Ducotronic_CO-RH_sensor.xml new file mode 100644 index 00000000..22957b15 --- /dev/null +++ b/openzwave/duco/Ducotronic_CO-RH_sensor.xml @@ -0,0 +1,140 @@ + + + + + Duco CO2/RH sensor + The DUCO CO2 sensor measures the indoor CO2 levels and temperature. This is a good indication for the indoor air quality.Duco Tronic System + The Duco Tronic System is a demand-driven natural ventilation system that always provides a balance between controlled natural ventilation and a central mechanical extraction. + The demand for ventilation is determined based on air quality (CO 2 ) in the living spaces, the relative humidity (RH) in the 'wet' rooms and outdoor temperature readings. + These values ​​are measured by means of various sensors in different rooms. The sensors communicate wirelessly via the Z-wave protocol with the electronically controlled by the air supply + grilles and DucoBox the mechanical removal of the polluted and humid air controls. This electronic control ensures that only where a ventilation when needed, so the energy loss is limited. + Moreover, the Duco Tronic System takes into account the temperature and adjusts to the weather conditions. If it gets colder outside, it will automatically schedule a higher CO 2 target gain. T + his opens it progresses less rapidly and less far. When the weather warms up, the opposite is true. In extreme heat is ventilated only by those grids where the lowest temperature measured, for example, + on the shady side of the building. The measurement of the outside temperature is done by means of a sensor located in the control unit of the air vents situated. Thanks to the electronically controlled grids + within the 'Duco Tronic System requires the user to do anything. The system ventilates automatically . Still, the resident boss and he may, if necessary or desired, the air supply and exhaust manually. + Over time, the system automatically switches back to the most optimal position. All components, sensors, DucoBox and grills are aesthetically designed, fast and easy to install, use and maintenance. + http://www.openzwave.com/device-database/XXXX:XXXX:XXXX + https://www.duco.eu/nl-nl-gearchiveerde-systemen + https://www.duco.eu/nl-nl-gearchiveerde-systemen + images/DefaultProductImage.png + https://www.duco.eu/Wes/CDN/1/Attachments/GH_DucoTronic%20System%20Z-wave_(nl)_online%20garantie_LowRes_635500206155264045.pdf + + Press all 4 buttons to enter installer mode. Next pres button 1 to add the device to a z-wave network. + + Press all 4 buttons to enter installer mode. Next press and hold button 1 and 2 to remove the device from a z-wave network. + https://products.z-wavealliance.org/products/49 + CEPT (Europe) + 00001801/G12809 + + Created the config file from scratch based on information from https://products.z-wavealliance.org/products/49 and http://devel.pepper1.net/zwavedb/device/156 + Remove auto on group 1, cleanup MetaDataItem + + + + + + + + + + + + + + + + + + + + + + + + + + + How often the value is measured(example: if value=60, the sensor value is measured every 60 seconds) + + + + + Set point CO2: Used in ‘automatic mode’. (button 4) if the device is a CO2 sensor. The CO2 level in a room is a good indication of the air quality in this room. + When the CO2 level is above this set point, the room needs more ventilation. Consequently, the CO2 sensor will open the associated grating unit. + + + + + Set point RH: Used in ‘automatic mode’. (button 4) if the device is a humidity sensor. The humidity level in a room is a good indication of the air quality in this room. + When the RH level is above this set point, the room needs more ventilation. Consequently, the RH sensor will open the associated grating unit. + + + + + The value when button1 is pressed. Values above 99 will be capped to 99 (maximum) used in association group 1 + + + + + The value when button2 is pressed. Values above 99 will be capped to 99 (maximum) used in association group 1 + + + + + The value when button3 is pressed. Values above 99 will be capped to 99 (maximum) used in association group 1 + + + + + The minimum value that can be send by the CO2 sensor when it is in automatic mode. + + + + + Temperature high set point: used in association group 2 or 3 + + + + + Temperature low set point: used in association group 2 or 3 + + + + + Temperature delta set point: used in association group 4 + + + + + RH high set point: used in association group 5 or 6 + + + + + RH low set point: used in group5 or 6 + + + + + RH delta set point: used in group7 + + + + + CO2 high set point: not available in RH sensor + + + + + CO2 low set point: not available in RH sensor + + + + + CO2 delta set point: not available in RH sensor + + + + + diff --git a/openzwave/duwi/05458.xml b/openzwave/duwi/05458.xml new file mode 100644 index 00000000..07038457 --- /dev/null +++ b/openzwave/duwi/05458.xml @@ -0,0 +1,161 @@ + + + + + + + + + + + + + + + 0 Disabled (Default). + 1 - 65535, automatically switch off after a user defined time + + + Defines how to interpret RF Off command. + Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; + Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled). + + + + + + + Defines if the dimmer shall ignore start level in StartLevelChange command despite it is specified or not. + + + + + Time to dim on button presses and Set command (if it has no duration specified). + If not 0, dimming will be done smoothly to preserve bulb life. + 0 : Instantly. + 1 - 255 : in 10ms units (Default 30). + + + + Time to dim on button holds and StartLevel Change command (if it has no duration specified). + + + Defines if the dimmer shall set maximum light level on On command. + By default on On command dimmer restores last level. + This parameter allows to configure to set maximum level on second On command (if already On) or to always switch on to maximum level. + + + + + + Time to dim on double click Off button for Baby-Dim function. + This function works only if the load is operated by single press and hold button action. + If enabled, the device will wait for a click timeout to see if the second click would be pressed. + This will introduce a small delay for single click commands. + 0 : Disabled (Default). + 1 - 99 : in minutes. + + + + Target level on which to stop while executing Baby Dimming. Can be 0 to completely switch off the light. + + + Typical time used to differentiate click, hold, double and triple clicks. + + + + + + + If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. + In this mode buttons are not linked with the switch anymore. + They can be used separately: buttons to control remote device, switch will operate by RF commands only. + + + + + + Defines which command should be sent on button single press or hold. + Basic and Scene Activation commands are sent to Association group. + Use Scene Controller Conf to set up Scene ID for Scene Activation. + Switch All commands are sent broadcast. + + + + + + + + + + + Defines which command should be sent on button double press or press-hold. + Basic and Scene Activation commands are sent to Association group. + Use Scene Controller Conf to set up Scene ID for Scene Activation. + Switch All commands are sent broadcast. + If not disabled, the device will wait for a click timeout to see if the second click would be pressed. + This will introduce a small delay for single click commands. + + + + + + + + + + + + + + + + Defines how to interpret button Down press. Depends on "Switch by buttons" parameter. + If not Disabled this parameter will affect the action selected by the latter parameter. + Can be used in conjunction with Auto Off function. + + + + + + + + + Maximum level should be greater than minimal level. Set to 0 to work as a switch (off or full on only), or set to 10 - 99 + + + Set to 0 to use previous light level, or set to 1 - 99 + + + NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 1. For other bulbs use default value. + + + NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 40. For other bulbs use default value. + + + NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 20. For other bulbs use default value. + + + NB: Do not touch these settings if you are not sure what they mean! + + + + + + + + + + + + + + diff --git a/openzwave/duwi/ZWES1000.xml b/openzwave/duwi/ZWES1000.xml new file mode 100644 index 00000000..bc6f344d --- /dev/null +++ b/openzwave/duwi/ZWES1000.xml @@ -0,0 +1,19 @@ + + + http://www.openzwave.com/device-database/0064:0000:2001 + images/duwi/ZWES1000.png + https://products.z-wavealliance.org/products/351/ + CEPT (Europe) + For wireless switching of: light bulbs, HV and LV halogen lamps or electrical equipment (e.g. fans). Combinable with all Z-Wave transmitters and remote controls, with installation in splash-proof junction box IP 44, can be selectively installed in flush-mounted power points and canopies or triggered directly via wireless rockers. + ZW-ES-1000 - Flush-mount Z-Wave switch + http://www.duewi.de/index.php?productid=29184 + http://www.duewi.de/index.php?productid=37347 + ZW-ES-1000 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/338/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/351/xml + + + + + diff --git a/openzwave/duwi/ZWESJ300.xml b/openzwave/duwi/ZWESJ300.xml new file mode 100644 index 00000000..64897761 --- /dev/null +++ b/openzwave/duwi/ZWESJ300.xml @@ -0,0 +1,18 @@ + + + + + + + + + + Continuous operation. 0x01-0x7F: 1-127 seconds in 1-second steps. 0x80-0xFE: 130-1390 seconds (0xFE) in 10 second-steps. 0xFF: 120 seconds (default; + + + + + + + + diff --git a/openzwave/duwi/zw-edan-300.xml b/openzwave/duwi/zw-edan-300.xml new file mode 100644 index 00000000..453c06a7 --- /dev/null +++ b/openzwave/duwi/zw-edan-300.xml @@ -0,0 +1,17 @@ + + + http://www.openzwave.com/device-database/0064:0000:0001 + images/duwi/zw-edan-300.png + https://products.z-wavealliance.org/products/337/ + ZW-EDAN-300 - Flush-mount Z-Wave dimmer + CEPT (Europe) + ZW-EDAN-300 + For wireless dimming of: light bulbs, HV and LV halogen lamps with conventional transformer. Combinable with all Z-Wave transmitters and remote controls. For installation in splash-proof junction box IP 44, can be selectively installed in flush-mounted power points and canopies or triggered directly via wireless rockers. + http://www.duewi.de/index.php?productid=29184 + http://www.duewi.de/index.php?productid=37321 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/337/xml + + + + diff --git a/openzwave/duwi/zw-zdan-300.xml b/openzwave/duwi/zw-zdan-300.xml new file mode 100644 index 00000000..decd9d64 --- /dev/null +++ b/openzwave/duwi/zw-zdan-300.xml @@ -0,0 +1,17 @@ + + + http://www.openzwave.com/device-database/0064:0000:1001 + images/duwi/zw-zdan-300.png + https://products.z-wavealliance.org/products/370/ + CEPT (Europe) + ZW-ZDAN-300 + http://www.duewi.de/index.php?productid=37324 + For wireless dimming of: light bulbs, HV and LV halogen lamps with conventional transformer, combinable with all Z-Wave transmitters and remote controls. + http://www.duewi.de/index.php?productid=29184 + ZW-ZDAN-300 - Z-Wave Plug-in Dimmer + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/370/xml + + + + diff --git a/openzwave/duwi/zwfb.xml b/openzwave/duwi/zwfb.xml new file mode 100644 index 00000000..c6c1e0ca --- /dev/null +++ b/openzwave/duwi/zwfb.xml @@ -0,0 +1,133 @@ + + + + + + + + This parameter defines the command to be sent to devices of control group No1 when the related button is pressed (association group 2) + + + + + + + + + This parameter defines the command to be sent to devices of control group No2 when the related button is pressed (association group 3) + + + + + + + + + This parameter defines the command to be sent to devices of control group No3 when the related button is pressed (association group 4) + + + + + + + + + This parameter defines the command to be sent to devices of control group No4 when the related button is pressed (association group 5) + + + + + + + + + This parameter defines the command to be sent to devices of control group No5 when the related button is pressed (association group 6) + + + + + + + + + This parameter defines the command to be sent to devices of control group No6 when the related button is pressed (association group 7) + + + + + + + + + This parameter defines the command to be sent to devices of control group No7 when the related button is pressed (association group 8) + + + + + + + + + This parameter defines the command to be sent to devices of control scene group No1 when the related button is pressed (association group 9) + + + + + + + + + This parameter defines the command to be sent to devices of control scene group No2 when the related button is pressed (association group 10) + + + + + + + + + This parameter defines the command to be sent to devices of control scene group No3 when the related button is pressed (association group 11) + + + + + + + + + This parameter defines the command to be sent to devices of control group All On/Off when the related button is pressed (association group 12) + + + + + + + + + Send the following Switch All ON/OFF commands + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/duwi/zwws.xml b/openzwave/duwi/zwws.xml new file mode 100644 index 00000000..b6951dd5 --- /dev/null +++ b/openzwave/duwi/zwws.xml @@ -0,0 +1,18 @@ + + + http://www.openzwave.com/device-database/0064:0000:5002 + images/duwi/zwws.png + https://products.z-wavealliance.org/products/342/ + CEPT (Europe) + http://www.duewi.de/index.php?productid=37276 + http://www.duewi.de/index.php?productid=29184 + For wireless switching, resp. control of: all Z-Wave wireless switch inserts and wireless intermediate plugs, existing installations can also be expanded without flush-mounted power point, high flexibility with installation due to extremely flat design, to stick or screw on to various substrates, for installation in existing switch box or clipping-in in multiple combinations. + ZWWS - Z-Wave wall-mounted Wall Switch + ZWWS + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/339/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/342/xml + + + + diff --git a/openzwave/ecodim/0.7.xml b/openzwave/ecodim/0.7.xml new file mode 100644 index 00000000..5fee8ee9 --- /dev/null +++ b/openzwave/ecodim/0.7.xml @@ -0,0 +1,99 @@ + + + + ECO-DIM.07 Z-Wave LED dimmer + ECO-DIM.07 Z-Wave is a push/rotary dimmer for LED lights. +The dimmer has a range of 0-200W LED, and is able to dim 230V halogen and incandescent bulds, dimable LED-drivers and electronic transfomers. +The minimum and maximum light level of the dimmer can be adjusted via a potentiometer. It is protected against overload and interference signals. +Installation can be done via 2 wires, there is no need for a neutral wire! +It is suitable for most popular smarthome systems, and the frame systems of the most popular brands can be used: Busch-Jaeger, Merten by Schneider, Berker by Hager, Niko, Gira, Jung and Peha. +The dimmer is compatible with 95% of all dimmable LED lights. + http://www.openzwave.com/device-database/0431:0001:0202 + https://www.ecodim.nl/eco-dim07-z-wave-druk-draai-led-dimmer-fase-afsnij.html + https://www.ecodim.nl/service/ + images/ecodim/0.7.jpg + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3796/Z-Wave%20Dimmer%20Controller%20V1.4%20(1).pdf + Double press the reset button on the device then initiate inclusion on your z-wave controller. + Press the reset button three times on the device then initiate exclusion on your z-wave controller. + Push reset button for 5 seconds. + https://products.z-wavealliance.org/products/3796/ + CEPT (Europe) + ECO-DIM.07 Z-Wave + + Information from manufacturer website and manual + Change ProductManual link format + + + + + + + + State After Power Restored: The state the switch should return to once power is restored after power failure. + Default value: 0 + 0 - Off. + 1 - On. + 2 - Returns to level before Power Outage + + + + + Notification when Load status change: The Dimmer will send notification to associated device (Group Lifeline) when the status of Dimmer load is changed. + Default value: 1 + 0 - The function is disabled. + 1 - Send Switch Multilevel Report. + + + + + Default dimming speed,unit is second. Valid values: 0-100. + Default value: 5 + 0 - Instanly. + 1 - Fast. + ... + 100 - Slow. + + + + + + Enable or Disable external switch to pair network. + Default value: 0 + 0 - Disable. + 1 - Enable. + + + + + Setting dimming way. + Default value: 0 + 0 - Linear dimming. + 1 - Logarithmic dimming. + + + + + Setting default brightness when turn on the dimmer from off status. + Setting of 0 means that the dimmer will use parameter 1. + Default value: 0 + Valid values: 0-99 + + + + + Setting delay time when turn off, unit is second. + Default value: 0 + Valid values: 0-60 + + + + + + + + + + + + + diff --git a/openzwave/ecolink/doorwindow.xml b/openzwave/ecolink/doorwindow.xml new file mode 100644 index 00000000..3b3bc44a --- /dev/null +++ b/openzwave/ecolink/doorwindow.xml @@ -0,0 +1,64 @@ + + + http://www.openzwave.com/device-database/014A:0002:0001 + images/ecolink/doorwindow.png + https://products.z-wavealliance.org/products/1498/ + U.S. / Canada / Mexico + EU Z-WAVE DOOR WINDOW SENSOR + Includes Brown & White covers +Sleek design virtually disappears +Easy-to-open case requires no special tools +Case tamper protection +Ideal for double-hung window +Up to 3 year battery life on 1 CR123A lithium battery +Uses rare earth magnet for up to 5/8th inch gap detection +Includes white and brown cases + DWZWAVE2.5-ECO + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/790/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1498/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2927/xml + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2927/EU Z-wave Door Window Sensor H114101 ZWAVE_Ver03.pdf + The sensor will wake up every so often and when the case is closed to send a Wake-Up Notification to allow the life line master node controller that the sensor is now available for any queued messages that the controller may have for the sensor. The time between Wake-Up Notifications can be configured with the Wake-Up Notification command class to be between 1 hour and 1 week with interval steps of 200 seconds. + The sensor must be added to a Z-Wave network prior to use. To include the sensor in a network both the sensor and the network controller must be in inclusion mode at the same time. Refer to the instructions provided by the manufacturer of your specific controller for details on initiating the controller’s inclusion mode. + +STEP ONE Start by placing the controller into inclusion mode. + +STEP TWO Activate inclusion mode for the sensor by removing the plastic pull-tab from the back of the sensor. When the + inclusion process is complete, the LED on the sensor will be solid blue, then go out. + +STEP THREE Test the sensor. Place the magnet next to the sensor to represent a closed position (see Installation section + to see where to position the magnet). If the LED flashes ONE TIME, it is successfully communicating on your + Zwave network. If the LED on the sensor flashes slow and steady for 5 seconds, you need to repeat the + inclusion process. + + Exclusion mode on the senor is initiated following the same exact procedure as inclusion. + To restore this sensor to factory default settings, follow the instructions in this manual to exclude this sensor from the Z-Wave network. Upon completion of removal from the network the sensor will restore itself to factory default settings automatically. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + https://products.z-wavealliance.org/products/2927/ + CEPT (Europe) + H114101 + + + + + true + + + + + + true + + + + + + + + + + diff --git a/openzwave/ecolink/firefighter.xml b/openzwave/ecolink/firefighter.xml new file mode 100644 index 00000000..3e562ebc --- /dev/null +++ b/openzwave/ecolink/firefighter.xml @@ -0,0 +1,49 @@ + + + http://www.openzwave.com/device-database/014A:000F:0005 + images/ecolink/firefighter.png + https://products.z-wavealliance.org/products/1827/ + The Ecolink Z-Wave Plus FireFighter is an audio detector that listens for your smoke, fire, or Carbon Monoxide alarm and transmits as alert back to your hub to notify you of an event. It is easy to include/exclude with your hub, detector both temporal 3 and 4 patterns of your sensing device, has a 5 year battery life on (1) CR123A Lithium battery included. Dimensions are 3 1/8" x 1" tall. Certified to work with most Z-Wave enabled hubs on the market. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1827/1 - Ecolink FireFighter Z-wave plus Manual (standard).pdf + FF-ZWAVE5-ECO + Ecolink Z-Wave Plus FireFighter + Removing Sensor +A) Any sensor can be removed from any Z-Wave Plus network with any Z-Wave Plus controller. Follow the directions to put your Z-Wave Plus Controller into Z-Wave Plus exclusion mode. +B) Press the learn button located near the LED and Tamper switch. If successfully removed from the Z-Wave Plus network, the sensor’s LED should blink continuously if successful. + + Factory Default + The FireFighter™ can be restored back to factory default settings which will remove its Z-Wave Plus node ID from the sensor (but not the controller) with the following steps. +A) Put the battery into the sensor. +B) Do not press the tamper switch. +C) Hold the learn button down for 10 seconds until the LED turns RED. +D) Release the learn button and wait for the sensor’s green LED to “breath” on and off continuously. The sensor is now ready to be added to a Z-Wave Plus network, and all settings have been restored. + +Please use this procedure only when the network primary +controller is missing or otherwise inoperable. + U.S. / Canada / Mexico + Adding Sensor +A) Be sure that the Z-Wave Plus Controller you are using is compatible with the FireFighter™. +B) Either mount or move the sensor as close as possible to the place in the building where the sensor is to be mounted in order that the new Z-Wave Plus node is added to the correct place in the mesh network routing tables. +C) To add the sensor to an existing Z-Wave Plus network, follow the directions to put your Z-Wave Plus Controller into add (inclusion) mode. The FireFighter™ enters add and remove (inclusion/exclusion) mode on pressing the learn button for 1 second which is located on the PCB between the LED and the tamper switch. If the LED starts blinking continuously, the sensor has no node ID and was not successfully added, so start step C over again. +D) If after 5 seconds the LED is not blinking, look on the Z-Wave Plus controller’s interface for feedback on whether the sensor was added successfully. If you do not see any feedback that the sensor was added, follow directions for removing the sensor from a Z-Wave Plus network, and then try adding the sensor again. If you are still having problems, you may need to add additional Z-Wave Plus listening devices in-between the controller and the sensor. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1827/xml + + + + + + true + + + + + + + + + diff --git a/openzwave/ecolink/floodfreeze.xml b/openzwave/ecolink/floodfreeze.xml new file mode 100644 index 00000000..b61cdefe --- /dev/null +++ b/openzwave/ecolink/floodfreeze.xml @@ -0,0 +1,40 @@ + + + + http://www.openzwave.com/device-database/014A:0010:0005 + images/ecolink/floodfreeze.png + -Z-Wave Plus enabled device which detects flood and freeze. +-Reports tamper condition when cover is open. +Product Specifications +-For indoor use only +-Operating frequency: 908.42 MHz +-Operating temperature: 0° – 49°C, 32° – 120°F (ambient temperature) +-Operating humidity 5-95% non-condensing +-Battery type required: 3V Lithium CR123A +-Battery life approximately 5 years + + http://www.openzwave.com/device-database/XXXX:XXXX:XXXX + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2551/Z-Wave%20Plus%20Wireless%20Flood%20Sensor%20with%20a%20Probe%20FLF-ZWAVE5_V5.pdf + Put Z-Wave Controller into inclusion mode. Insert battery into sensor to enter inclusion mode. + Put Z-Wave Controller into exclusion mode. Remove battery for 1 second and reinsert to enter exclusion mode. + + https://products.z-wavealliance.org/products/2551/ + U.S. / Canada / Mexico + FLF-ZWAVE5 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2551/xml + + + + + + + + + + + + diff --git a/openzwave/ecolink/motion.xml b/openzwave/ecolink/motion.xml new file mode 100644 index 00000000..a2b9b521 --- /dev/null +++ b/openzwave/ecolink/motion.xml @@ -0,0 +1,73 @@ + + + http://www.openzwave.com/device-database/014A:0001:0004 + images/ecolink/motion.png + https://products.z-wavealliance.org/products/2928/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2928/EU Z-wave PIR H214101 ZWAVE_Ver02.pdf + The sensor must be added to a Z-Wave network prior to use. To include the sensor in a network, both the sensor and the network controller must be in inclusion mode at the same time. + +Activate inclusion mode for the sensor by removing the battery isolation pull tab, or by inserting the battery (see next section for battery installation tips). When the inclusion process is complete the red LED will turn on for approximately 10 seconds and then it will go out. If the LED continues to flash repeat the inclusion process. + +Refer to the instructions provided by the manufacturer of your specific controller for details on initiating the controller’s inclusion mode. + + +STEP ONE Start by placing the controller into inclusion mode. + +STEP TWO Activate inclusion mode for the sensor by removing the battery isolation pull tab, or by inserting the battery (see next section for battery installation tips). When the inclusion process is complete the red LED will turn on for approximately 10 seconds and then it will go out. If the LED continues to flash repeat the inclusion process. +STEP THREE Test the motion sensor before mounting it. Place the sensor in an unoccupied room. Leave the room for at least 4 minutes. Return to the room and pass in front of the sensor lens. The LED will flash once to indicate that motion was detected. + + H214101 + To restore this sensor to factory default settings, follow the instructions in this manual to exclude this sensor from the Z-Wave network. Upon completion of removal from the network the sensor will restore itself to factory default settings automatically. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + • For indoor use only +• Operating frequency: 908.42 MHz +• Operating range: Up to 100 feet (30.5 meters) line-of-sight +• Operating temperature: 0˚C to 49˚C, 32˚F to 120˚F (ambient temperature) +• Detection radius: 39 feet (see detection region diagram) +• Detection angle: 45 degrees in either direction from the sensor’s center +• Battery type: 3V Lithium CR123A +• Battery life: approximately 3 years +• Passive Infrared (PIR) based technology + EU Z-WAVE PIR MOTION SENSOR + To save power, this sensor sleeps most of the time and is therefore not awake to receive messages from a gateway for testing. Removing the top case from the sensor will put in device into a tampered mode in which the sensor will stay awake and able to receive messages. Most of the time an end user would not do this, but if the sensor needs to be configured after inclusion, an end user can follow the instructions below for sending Wake-Up notifications. + U.S. / Canada / Mexico / CEPT (Europe) + Exclusion mode on the sensor is initiated following the same exact procedure as inclusion. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1500/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2928/xml + + + + + + true + + + + + + + Configures the sensor to send or not send Basic Set commands of 0x00 to nodes in Association group 2 turning the devices off when the sensor is in a restored state (i.e. motion not detected). + By default the sensor does NOT send Basic Set commands of 0x00. + + + + + + + Configures the sensor to either to send or not to send Sensor Binary Report commands to Association Group 1 when the sensor is faulted and restored. + + + + + + + + + + + + + diff --git a/openzwave/ecolink/sensor.xml b/openzwave/ecolink/sensor.xml new file mode 100644 index 00000000..6cefcc67 --- /dev/null +++ b/openzwave/ecolink/sensor.xml @@ -0,0 +1,37 @@ + + + http://www.openzwave.com/device-database/014A:0001:0001 + images/ecolink/sensor.png + https://products.z-wavealliance.org/products/791/ + PIRZWAVE1 + Ecolink Motion Sensor + The PIR Motion Sensor transmits to a Z-Wave gateway/controller when it detects movement within its field of view. + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/791/xml + + + + + + true + + + + + + Enable/Disable Basic Sets of 0x00 on a fault restore to nodes in Group 2 + + + + + + + + + + + + diff --git a/openzwave/ecolink/tiltsensor.xml b/openzwave/ecolink/tiltsensor.xml new file mode 100644 index 00000000..d206751f --- /dev/null +++ b/openzwave/ecolink/tiltsensor.xml @@ -0,0 +1,52 @@ + + + http://www.openzwave.com/device-database/014A:0003:0001 + images/ecolink/tiltsensor.png + https://products.z-wavealliance.org/products/816/ + TILTZWAVE1 + Ecolink Garage Door Tilt Sensor + U.S. / Canada / Mexico + • For indoor use only +• Operating frequency: 908.42 MHz +• Operating range: Up to 100 feet (30.5 meters) line-of-sight +• Operating temperature: 0˚C to 49˚C, 32˚F to 120˚F (ambient temperature) +• Battery type: 3V Lithium CR123A +• Battery life: 5 to 8 years depending upon operating conditions + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/816/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1501/xml + + https://products.z-wavealliance.org/products/1501/ + Once the controller is in exclusion mode, remove the battery pull tab OR insert the battery into the sensor to initiate power up. + Simply remove the sensor cover to wake up for configuration. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1501/Tilt_ZWave_Plus_Manual_R1.04_021816kgs.pdf + Once the controller is in inclusion mode, remove the battery pull tab OR insert the battery to power up the sensor. + U.S. / Canada / Mexico + TILTZWAVE2.5-ECO + To reset the sensor to factory default, place the controller in exclusion mode and then insert the battery into the sensor to initiate power up. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + + + + true + + + + + + Enable/Disable Basic Sets of 0x00 on a fault restore to nodes in Group 2 + + + + + + + + + + + + diff --git a/openzwave/econet/ezw1204.xml b/openzwave/econet/ezw1204.xml new file mode 100644 index 00000000..f067ef17 --- /dev/null +++ b/openzwave/econet/ezw1204.xml @@ -0,0 +1,37 @@ + + + EcoNet Z-Wave Plus Water Leak Sensor + Damage from water leaks can be both devastating and costly, leading to both unnecessary expenses and stress. Protect your home from water damage with EcoNet’s EZW1204 Z-Wave leak sensor. This sleek and compact leak sensor can be placed below dishwashers, in laundry rooms, beside hot water tanks, on a wall close a sump pump and more. It comes with an optional snap-in wall mount piece. +Z-Wave Plus technology allows this sensor to communicate with any Z-Wave enabled network and controller so notifications can be sent to your smartphone or other enabled smart devices. Its compatible with most popular Smart Home systems including Samsung’s SmartThings, Wink, Vera and Homeseer. It has a wireless range of 30 meters in a clear line of sight. + + http://www.openzwave.com/device-database/015D:C41C:2003 + https://www.econetshop.com/products.html + https://www.econetshop.com/support + images/econet/ezw1204.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2748/EZW1204-Manual-Guide%C2%A0171220.pdf + Open the shell, wake up immediately + Press the inclusion switch 3 or more times rapidly (within 0.5s). It is recommended to keep the EZW1204 within 1M/3ft of the controller. +(Set controller to inclusion mode first) + Press the inclusion switch 3 or more times rapidly (within 0.5s). It is recommended to keep the EZW1204 within 1M/3ft of the controller. +(Set controller to exclusion mode first) + Press and hold down the inclusion switch for 5 or more seconds. +Note: this should only be used in the event your network's primary controller is missing or otherwise inoperable + https://products.z-wavealliance.org/products/2748/ + U.S. / Canada / Mexico + EZW1204 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2748/xml + + + + + + + + + + + + + + diff --git a/openzwave/electronicsolutions/dbmz.xml b/openzwave/electronicsolutions/dbmz.xml new file mode 100644 index 00000000..6df113d3 --- /dev/null +++ b/openzwave/electronicsolutions/dbmz.xml @@ -0,0 +1,46 @@ + + + http://www.openzwave.com/device-database/0033:3032:5250 + images/electronicsolutions/dbmz.png + https://products.z-wavealliance.org/products/305/ + DC Motor Controller for window coverings.Z-Wave DC motor control, packaged in a “Plug & Play” Box. Z-Wave radio allows for bi-directional RF communications with other Z-Wave products in the market. Allows for total switched load of up to 2 Amps at 27VDC. + +By utilizing the Z-Wave standard, the DBMZ is guaranteed interoperability between systems and devices from other Z-Wave enabled products. + +In order for scene functionality to operate correctly, the calibration sequence MUST be performed. See the technical documentation for more details. + +DC Power supply needed, see Power Supplies for selections. + +This product has passed a stringent conformance test to assure it meets the Z-Wave standard for complete interoperability with all other devices and controls. + Malaysia / India / Hong Kong / CEPT (Europe) + http://elec-solutions.com/products/z-wave/dbmz.html + http://elec-solutions.com/home.html + DC Motor Controller - Window coverings + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/40/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/41/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/42/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/305/xml + + DBMZ EU + + + + + Unit calibration state + + + + + + Unit motor direction state + + + + + Unit tilt feature state + + + + + diff --git a/openzwave/enblink/ss201-us-w_1308.xml b/openzwave/enblink/ss201-us-w_1308.xml new file mode 100644 index 00000000..98c00281 --- /dev/null +++ b/openzwave/enblink/ss201-us-w_1308.xml @@ -0,0 +1,16 @@ + + + http://www.openzwave.com/device-database/014D:0001:0001 + images/enblink/ss201-us-w_1308.png + https://products.z-wavealliance.org/products/969/ + SS201-US-W + U.S. / Canada / Mexico + Enblink GoogleTV Controller + Enblink turns Google TV into a home automation hub. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/937/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/969/xml + + http://www.enblink.com/ + + diff --git a/openzwave/enerwave/zw15rmplus.xml b/openzwave/enerwave/zw15rmplus.xml new file mode 100644 index 00000000..89a59daf --- /dev/null +++ b/openzwave/enerwave/zw15rmplus.xml @@ -0,0 +1,57 @@ + + + http://www.openzwave.com/device-database/011A:0105:0111 + images/enerwave/zw15rmplus.png + https://products.z-wavealliance.org/products/1776/ + The ZW15RM TR Duplex Receptacle is a perfect wireless manual and remote on/off control replacement of regular receptacles, controlling table and floor lamps, small appliances, etc. It provides two different type outlets. One outlet with Z-Wave mark has programmable functions such as scenes, association, schedule event, etc. It is fully interoperable with other Z-Wave certified device from other manufacturers and/or other applications. It can report wattage energy usage or kWh energy usage to a Z-Wave gateway.It has a Blue LED on the face cover indicates the status of the controlled outlet and/or act as a night light. The other outlet with Tamper-Resistant feature provides constant power, helps you and your families prevent electrical injuries. + When the controller is in add mode and the blue LED is blinking on the +ZW15RM, press and hold the program button of ZW15RM for 3 second, and +then the controller will verify the add. + IN-Wall Smart Meter TR Duplex Receptacle + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1776/ZW15RM(20160509 ).pdf + When the controller is in remove mode, press and hold the program button of +ZW15RM for 3 second, and then the controller will remove it from the current +Z-Wave network, and the LED will blink on the receptacle,when power on. + Once program button is pressed and hold for 10 second, the device will send a device reset locally notification to controller. Then clear all of information for +the network, and restore factory defaults, and reset the module. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + ZW15RM + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1776/xml + + + + + + Synchronization of load power and LED indicator + + + + + How often to send the energy report for the moment-in-time usage (METER_REPORT version) automatically in minutes. 0 = disabled. + + + How often to send the energy report for the moment-in-time usage (SENSOR_MULTILEVEL_REPORT version) automatically in minutes. 0 = disabled. + + + How often to send the energy report for the accumulated energy usage usage (METER_REPORT) automatically in minutes. 0 = disabled. + + + Enable automatic notifications when there is a change in wattage. + + + + + + + How much the wattage needs to change by to trigger the wattage change notifications. Units are 1-10th of a watt; 0-255: 0.0-25.5W + + + + + + + + + + diff --git a/openzwave/enerwave/zw15s.xml b/openzwave/enerwave/zw15s.xml new file mode 100644 index 00000000..c839eec8 --- /dev/null +++ b/openzwave/enerwave/zw15s.xml @@ -0,0 +1,22 @@ + + + + + + + Set to 1 for LED to be in sync with switch. + + + + + Set to 1 for "up" to turn the load off. + + + + + + + + + + diff --git a/openzwave/enerwave/zw20r.xml b/openzwave/enerwave/zw20r.xml new file mode 100644 index 00000000..c9a00d0c --- /dev/null +++ b/openzwave/enerwave/zw20r.xml @@ -0,0 +1,23 @@ + + + http://www.openzwave.com/device-database/011A:0603:0101 + images/enerwave/zw20r.png + https://products.z-wavealliance.org/products/713/ + CEPT (Europe) + ZWN-RSM2 + Wenzhou MTLC Electric ZWN-RSM2 + Smart Lighting Control Module(RSM2) which can be used with traditional switch, for use with incandescent, incandescent, fluorescent, ballast , motor , meet customer's requirements. + http://www.smart-wave.us/product_show.asp?classid=2&ID=34 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/713/xml + + + + + + Set to 1 for LED to be in sync with switch. + + + + + diff --git a/openzwave/enerwave/zw20rm.xml b/openzwave/enerwave/zw20rm.xml new file mode 100644 index 00000000..4c853c0e --- /dev/null +++ b/openzwave/enerwave/zw20rm.xml @@ -0,0 +1,55 @@ + + + http://www.openzwave.com/device-database/011A:0101:0111 + images/enerwave/zw20rm.png + https://products.z-wavealliance.org/products/1766/ + PLUG-IN SMART METER APPLIANCE MODULE + ZWN-333M + This ZWN-333M Smart Meter Appliance Module is a Z-Wave enabled device and fully interoperable with other Z-Wave certified device from other manufacturers and/or other applications, which can report wattage energy usage or kWh energy usage to a Z-Wave gateway. In a Z-Wave network, ZWN-333M can be controlled to turn on/off to save energy, also act as a wireless repeater regardless of vendor to increase reliability of the network. With a horizontal design, the Smart Meter Appliance Module will not block other nearby AC outlets. + Once program button is pressed and hold for 3 second, the device will enter into +learn mode to accomplish adding or removing by controller. Refer to the instruction +for your primary controller to access the setup function and add or remove devices. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1766/ZWN-333M_20160506.pdf + Once program button is pressed and hold for 3 second, the device will enter into +learn mode to accomplish adding or removing by controller. Refer to the instruction +for your primary controller to access the setup function and add or remove devices. + Once program button is pressed and hold for 10 second, the device will send a device reset locally notification to controller. Then clear all of information for the network, and restore factory defaults, and reset the module. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1766/xml + + + + + + Synchronization of outlet power and LED indicator + + + + + How often to send the energy report for the moment-in-time usage (METER_REPORT version) automatically in minutes. 0 = disabled. + + + How often to send the energy report for the moment-in-time usage (SENSOR_MULTILEVEL_REPORT version) automatically in minutes. 0 = disabled. + + + How often to send the energy report for the accumulated energy usage usage (METER_REPORT) automatically in minutes. 0 = disabled. + + + Enable automatic notifications when there is a change in wattage. + + + + + + + How much the wattage needs to change by to trigger the wattage change notifications. Units are 1-10th of a watt; 0-255: 0.0-25.5W + + + + + + + + diff --git a/openzwave/enerwave/zw500d.xml b/openzwave/enerwave/zw500d.xml new file mode 100644 index 00000000..432c7e27 --- /dev/null +++ b/openzwave/enerwave/zw500d.xml @@ -0,0 +1,22 @@ + + + + + + + Set to 1 for LED to be in sync with switch. + + + + + Set to 1 for "up" to turn the load off. + + + + + + + + + + diff --git a/openzwave/enerwave/zwn-bpc.xml b/openzwave/enerwave/zwn-bpc.xml new file mode 100644 index 00000000..a37316f0 --- /dev/null +++ b/openzwave/enerwave/zwn-bpc.xml @@ -0,0 +1,34 @@ + + + http://www.openzwave.com/device-database/011A:0901:0601 + images/enerwave/zwn-bpc.png + https://products.z-wavealliance.org/products/2165/ + 3. Once program button is pressed and hold for 10 second, the device will send a device reset locally notification to controller. Then clear all the module. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + 1. When the controller is in add mode, press and hold the program button of ZWN-BPC for 2 second, and then the controller will verify the add. + Once short press the program button it will send singlecast wake up notification to controller devices. + U.S. / Canada / Mexico + The PIR Motion Sensor ZWN-BPC is a Z-Wave enabled device and is fully compatible with other Z-Wave certified device from other manufacturers. With the ZWN-BDS to monitor the environment and provide hand-free lighting control, it can also trigger a Z-Wave enabled alarm when motion is detected and when there is movement within or across the detection of coverage, one triggering signal will be transmitted to all associated Z-Wave devices. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2165/20170111 ZWN-BPC.pdf + 2. When the controller is in remove mode, press and hold the program button of ZWN-BPC for 2 second, and then the controller will remove it from the current Z-Wave network. + ZWN-BPC + Ceiling Mounted PIR Motion Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2165/xml + + + + + Sets the time after triggering the sensor to send the Basic OFF command. 0: Don't send Basic OFF. 1-240: N minutes. 241-255: 15 seconds. + + + + + true + + + + + + + + diff --git a/openzwave/enerwave/zwn-sc7.xml b/openzwave/enerwave/zwn-sc7.xml new file mode 100644 index 00000000..9a618332 --- /dev/null +++ b/openzwave/enerwave/zwn-sc7.xml @@ -0,0 +1,6 @@ + + + + + + diff --git a/openzwave/enerwave/zwnrsm1plus.xml b/openzwave/enerwave/zwnrsm1plus.xml new file mode 100644 index 00000000..55e6a672 --- /dev/null +++ b/openzwave/enerwave/zwnrsm1plus.xml @@ -0,0 +1,27 @@ + + + http://www.openzwave.com/device-database/011A:0605:0111 + images/enerwave/zwnrsm1plus.png + https://products.z-wavealliance.org/products/2242/ + ZWN-RSM2 + Smart Dual Relay Switch Module + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2242/ZWN-RSM2 2017-2-28.pdf + The ZWN-RSM2 Switch Module have two channels switch ,that is a component of lighting control system, it can not be used separately but should turn an existing switch into a Z-Wave switch. This ZWN-RSM2 module is a Z-Wave enabled device and is fully compatible with other Z-Wave certified device from other manufacturers. In a Z-Wave network, each device is designed to act as a wireless repeater. Once the ZWN-RSM2 module is installed and setup with in your wall, it will retransmit the RF signal from one device to another until the intended device to intended device is reached. This ensures that the signal is received by its intended destination + U.S. / Canada / Mexico + Once program button is pressed and hold for 10 second, the device will send a device reset locally notification to controller. Then clear all of information for the network, and restore factory defaults, and reset the module. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + When the controller is in remove mode,Press and release the program button of ZWN-RSM2 module, or Flick 3 times of the connected switch with Aux1 line (or Aux2 line) in 1.5 second. Then the controller will remove the module from current Z-Wave network. + When the controller is in add mode,Press and release the program button of ZWN-RSM2 module,or Flick 3 times of the connected switch with Aux1 line(or Aux 2 line) in 1.5 second. Then the controller will add the module into current Z-Wave network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1777/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2242/xml + + + + + + + + + + diff --git a/openzwave/enerwave/zwnrsm2plus.xml b/openzwave/enerwave/zwnrsm2plus.xml new file mode 100644 index 00000000..b6774b81 --- /dev/null +++ b/openzwave/enerwave/zwnrsm2plus.xml @@ -0,0 +1,37 @@ + + + ZWN-RSM2-PLUS Smart Dual Relay Switch Module + ZWN-RSM2-Plus Transform any home into a connected home with the Enerwave Z-Wave Plus Smart Dual Relay Wireless Lighting Control Module. The lighting control enables wireless control of on/off functions for standard table and floor lamps, and is compatible with incandescent, LED, Xenon, Halogen, fluorescent and compact fluorescent bulbs. + http://www.openzwave.com/device-database/011A:0606:0111 + https://enerwaveautomation.com/products/zwnrsm2/ + https://enerwaveautomation.com/products/zwnrsm2/ + images/enerwave/zwnrsm2plus.png + https://products.z-wavealliance.org/ProductManual/File?folder=%26filename=MarketCertificationFiles/2242/ZWN-RSM2%202017-2-28.pdf + Once program button is pressed and hold for 10 second, the device will send a device reset locally notification to controller. Then clear all of information for the network, and restore factory defaults, and reset the module. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + When the controller is in remove mode,Press and release the program button of ZWN-RSM2 module, or Flick 3 times of the connected switch with Aux1 line (or Aux2 line) in 1.5 second. Then the controller will remove the module from current Z-Wave network. + When the controller is in add mode,Press and release the program button of ZWN-RSM2 module,or Flick 3 times of the connected switch with Aux1 line(or Aux 2 line) in 1.5 second. Then the controller will add the module into current Z-Wave network. + U.S. / Canada / Mexico + + Original file was placeholder - had not revision entry + Wholesale replacement of placeholder file. Added information from mfg site + + + + + + true + + + + + ZWN-RSM2-PLUS can send unsolicited status reports to the primary controller (Node ID 0x1) when the switch is toggled if the controller is designed as a gateway. If your controller is not a gateway or does not need the status reported or you think it could confuse your Z-Wave network, you can use Command_Class_Configuration to disable this function. By default this function is disabled. ZWM-RSM2 disabled=0, enabled=255. ZWN-RSM2-PLUS disabled=0, enabled=1 + + + + + + + + + + diff --git a/openzwave/eurotronic/eur_airquality.xml b/openzwave/eurotronic/eur_airquality.xml new file mode 100644 index 00000000..9dd08f04 --- /dev/null +++ b/openzwave/eurotronic/eur_airquality.xml @@ -0,0 +1,121 @@ + + + + + http://www.openzwave.com/device-database/0148:0001:0005 + images/eurotronic/eur_airquality.png + Start Inclusion mode of your primary Z-Wave Controller. +Press the network button three times within 1 second. + https://eurotronic.org/wp-content/uploads/2020/02/LGS-Z-Wave-Plus_BDA_web_EN-1.pdf + Start Exclusion mode of your primary Z-Wave Controller. +Press the network button three times within 1 second. + Air Quality Sensor + Please use this procedure only when the network primary controller is missing or otherwise inoperable. + +Press and hold the network button for at least 10 seconds. The Air Quality Sensor Z-Wave Plus will indicate +the reset blinking pattern once the reset is completed. + + This Z-Wave sensor provides comprehensive information on indoor +air quality. +• Multicolor LED for signalling ventilation recommendations +• Returns the following values: + - VOC value (volatile organic compounds) in ppm + - CO2 value (as CO2 equivalent) in ppm + - Temperature (°C) + - Humidity (%) + - Dew point (°C) +• Supports Z-Wave Plus S2 security (encryption) +• Z-Wave repeater function +• Operation with plug-in power supply unit + + + Initial Metadata Import from https://eurotronic.org/wp-content/uploads/2020/02/LGS-Z-Wave-Plus_BDA_web_EN-1.pdf/ + + CEPT (Europe) + https://eurotronic.org/produkte/sensoren/luftguetesensor/ + + + + + + + + 0: No on change reporting (only time-based reports) + 1-50: report if temperature changed by delta = 0,1°C - 5,0°C + Default: 5 + + + + + + 0: No on change reporting (only time-based reports) + 1-10: report if humidity changed by delta = 1% ...10% + Default: 5 + + + + + Temperature in Degrees Celcius + Temperature in Degrees Fahrenheit + Default: Temperature in Degrees Celcius + + + + + + + No resolution (example 22°C) + 1/10 resolution (example 22.3°C) + 1/100 resolution (example 22.35°C) + Default: No resolution (example 22°C) + + + + + + + + No resolution (example 33%) + 1/10 resolution (example 33.4%) + 1/100 resolution (example 33.45% + Default: No resolution (example 33% + + + + + + + + 0: No on change reporting (only time-based reports) + 1-10: report if VOC reading changed by 100ppb - 1000ppb + Default: 5 + + + + + 0: No on change reporting (only time-based reports) + 1-10: report if CO2eq reading changed by 100ppm - 1000ppm + Default: 5 + + + + + 0: No air quality indication via LEDs + 1: Indicate measuered air quality via LEDs + Default: 1 + + + + + + + + + + + + + diff --git a/openzwave/eurotronic/eur_cometz.xml b/openzwave/eurotronic/eur_cometz.xml new file mode 100644 index 00000000..fb3982c5 --- /dev/null +++ b/openzwave/eurotronic/eur_cometz.xml @@ -0,0 +1,38 @@ + + + http://www.openzwave.com/device-database/0148:0001:0002 + images/eurotronic/eur_cometz.png + https://products.z-wavealliance.org/products/2202/ + CEPT (Europe) + LIZY001 + Comap LIZY001 + LIZY001 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1601/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2200/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2201/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2202/xml + + + + + + + + + + + + + + + + + + + + + 0 + + + diff --git a/openzwave/eurotronic/eur_spiritz.xml b/openzwave/eurotronic/eur_spiritz.xml new file mode 100644 index 00000000..8c0d6640 --- /dev/null +++ b/openzwave/eurotronic/eur_spiritz.xml @@ -0,0 +1,150 @@ + + + http://www.openzwave.com/device-database/0148:0001:0003 + images/eurotronic/eur_spiritz.png + https://products.z-wavealliance.org/products/2543/ + Start Inclusion mode of your primary Z-Wave Controller. +Press the Boost-Button. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2650/Spirit_Z-Wave_BAL_web_EN_view_05.pdf + Start Exclusion mode of your primary Z-Wave Controller. +Now press and hold the boost button of the Spirit Z-Wave Plus for at least 5 seconds. + KOMFORTHAUS Spirit Z-Wave Plus + 4260012711110 + UAE + Please use this procedure only when the network primary controller is missing or otherwise inoperable. + +Remove batteries. +Press and hold boost button. +While still holding boost button insert batteries. +The LCD shows RES. Release boost button. +To perform the factory reset press boost button. + + • Easy control for water radiators from any Z-Wave Controller +• Fits most European water radiators (wide range of additional adaptors for different manufacturers available) +• FLiRS for quick response time +• LED Backlit LCD +• Metal nut for reliable connection to the radiator +• 2 buttons for easy temperature regulation +• Battery level indicator +• Child Lock +• Over the Air update +• UK-Mode for upside down installation +• Open Window detection +• Automatic frost protection + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2543/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2650/xml + + https://products.z-wavealliance.org/products/2650/ + 4250848804063 + UAE + + + + + + + + + + + Off: No heating, only frost protection. + Heat: Room temperature will be kept at the configured setpoint. + Heat Eco: Energy save heating mode. Room temperature will be lowered to the configured eco setpoint in order to save energy. + Full Power: Full power heating. This mode is left automatically after 5 minutes. + Manufacturer Specific: Direct valve control mode. The valve opening percentage can be controlled using the switch multilevel command class. + + + + + + + + + + + + + + + + + + + + + + 0 + false + + + + + + + + Allows rotating the LCD contents by 180 degrees. + Default: Normal + + + + + + + 0: No Timeout, LCD always on. + 5-30: Timeout after 5-30s. + Default: 0 (LCD always on) + + + + + Default: Backlight enabled + + + + + + + Default: Send once a day + + + + + + + 0: Don't send temperature automatically. + 1-50: Report temperature at 0.1-5.0°C temperature difference. + Default: 5 (Delta = 0.5°C) + + + + + 0: Don't send Valve opening percentage automatically. + 1-100: Report valve opening percentage at a delta of 1-100%. + Default: 0 + + + + + Default: Medium sensibility + + + + + + + + + 206-255: -5.0 to -0.1°C. + 0-50: 0°C-5°C. + 128: External Temperature Sensor. + Default: 0 (0.0°C Offset) + + + + diff --git a/openzwave/eurotronic/eur_stellaz.xml b/openzwave/eurotronic/eur_stellaz.xml new file mode 100644 index 00000000..dac416d5 --- /dev/null +++ b/openzwave/eurotronic/eur_stellaz.xml @@ -0,0 +1,41 @@ + + + http://www.openzwave.com/device-database/0148:0001:0001 + images/eurotronic/eur_stellaz.png + https://products.z-wavealliance.org/products/826/ + CEPT (Europe) + Stella Z Thermostat + Stella Z + Radiator Controller + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/826/xml + + + + + + + + + + + + + + + + + + + + + + + + 0 + + + + + + diff --git a/openzwave/eurotronic/eur_temphumin.xml b/openzwave/eurotronic/eur_temphumin.xml new file mode 100644 index 00000000..c7c33ee3 --- /dev/null +++ b/openzwave/eurotronic/eur_temphumin.xml @@ -0,0 +1,92 @@ + + + + + http://www.openzwave.com/device-database/0148:0001:0004 + Temperature and Humidity Sensor + images/eurotronic/eur_temphumid.png + Start Inclusion mode of your primary Z-Wave Controller. +Press the network button three times within 1 second. + Please use this procedure only when the network primary controller is missing or otherwise inoperable. + +Press and hold the network button for at least 10 seconds. The temperature humidity sensor will indicate +the reset blinking pattern once the reset is completed. + + CEPT (Europe) + https://eurotronic.org/produkte/sensoren/temperatur-feuchte-sensor/ + https://eurotronic.org/ + + +This Z-Wave sensor provides comprehensive information on indoor +temperature and humidity. +• Returns the following values: + - Temperature (°C) + - Humidity (%) + - Dew point (°C) +• Supports Z-Wave Plus S2 security (encryption) + + + + Initial Metadata Import + + + + + + + + + 0: Don't report temperature changes + 1-50: Report temperature changes from 0,1°C - 5,0°C + Default: 5 + + + + + + 0: Don't report humidity changes + 1-10: report humidity changes in 1% steps + Default: 5 + + + + + 0: Temperature in Degrees Celcius + 1: Temperature in Degrees Fahrenheit + Default: 0 + + + + + + + 0: no decimal places + 1: one decimal place + 2: two decimal places + Default: 1 + + + + + 0: no decimal places + 1: one decimal place + 2: two decimal places + Default: 0 + + + + + + + + + + + + + diff --git a/openzwave/everspring/ad146.xml b/openzwave/everspring/ad146.xml new file mode 100644 index 00000000..4b0659c8 --- /dev/null +++ b/openzwave/everspring/ad146.xml @@ -0,0 +1,65 @@ + + + http://www.openzwave.com/device-database/0060:0002:0003 + images/everspring/ad146.png + https://products.z-wavealliance.org/products/1057/ + The In-Wall Dimmer Module is a Z-Wave enabled device which is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave enabled networks. Inclusion of this unit on other manufacturer’s Wireless Controller menu allows remote operation of the unit and the connected load. Z-Wave node in the system also acts as a repeater, so as to re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. + +The In-Wall Dimmer Module is designed to control the on/off status of lighting and appliances load in your house. The unit also provides dimmer function which is only applicable to light bulbs. AC 230V voltage, this module can support up to 300W resistive/ incandescent load, or 200W fluorescent load. + + (This procedure should only be used when the primary controller is no longer operational.) +1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. +2. Within 1 second of step 1, press link key again and hold until LED is off (about 5 sec.). +3. Node ID is excluded, and the unit is returned to the factory default state. + + 1. Put the Z-Wave Controller into inclusion mode. +2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. + + In-Wall Dimmer Module + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1057/Manual_AD146-0_20140728.pdf + CEPT (Europe) + 1. Put the Z-Wave Controller into exclusion mode. +2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. + + AD146-0 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1057/xml + + + + + + + 0 is off. 1 to 99 sets output level at specified value. +255 sets output level at last memorized level + + + + + Delaying time to report to Group 1 + + + + + Remember the last status: 0 (do not remember) | 1 (remember) + + + + + 0: Single Pole Double Throw (1: Toggle switch) + + + + + Output mode setting: 0 (dimming) | 1 (on/off) + + + + + + + + + + + diff --git a/openzwave/everspring/ad147.xml b/openzwave/everspring/ad147.xml new file mode 100644 index 00000000..8bd2565b --- /dev/null +++ b/openzwave/everspring/ad147.xml @@ -0,0 +1,56 @@ + + + http://www.openzwave.com/device-database/0060:0003:0003 + images/everspring/ad147.png + https://products.z-wavealliance.org/products/1527/ + 1. Put the Z-Wave Controller into exclusion mode. +2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. + 1. Put the Z-Wave Controller into inclusion mode. +2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. + wireless dimmer plug + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1527/Manual - AD147_20151007-A501112259R01.pdf + AD147-2 + 1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. +2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds). +3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes. +4. Use this procedure only in the event that the network primary controller is missing, or otherwise inoperable + NR + The mini Dimmer Plug is designed to control the on/off status of lighting and appliance load in your house. The unit also provides dimmer function which is only applicable to light bulbs. At 220-240V voltage, this Dimmer Plug can support connected load of 6W - 250W. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1065/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1527/xml + + + + + + + 0 is off. 1 to 99 sets output level at specified value. +255 sets output level at last memorized level + + + + + Delaying time to report to Group 1 + + + + + Remember the last status: 0 (do not remember) | 1 (remember) + + + + + Output mode setting: 0 (dimming) | 1 (on/off) + + + + + + + + + + + diff --git a/openzwave/everspring/an145.xml b/openzwave/everspring/an145.xml new file mode 100644 index 00000000..3a87ca7c --- /dev/null +++ b/openzwave/everspring/an145.xml @@ -0,0 +1,11 @@ + + + + + + + + + + + diff --git a/openzwave/everspring/an157.xml b/openzwave/everspring/an157.xml new file mode 100644 index 00000000..5df638b5 --- /dev/null +++ b/openzwave/everspring/an157.xml @@ -0,0 +1,24 @@ + + + http://www.openzwave.com/device-database/0060:0001:0004 + images/everspring/an157.png + https://products.z-wavealliance.org/products/895/ + Malaysia / Hong Kong / U.S. / Canada / Mexico / U.S. / Canada / Mexico / CEPT (Europe) / CEPT (Europe) / CEPT (Europe) / U.S. / Canada / Mexico + http://www.everspring.com/AN145.aspx + http://www.everspring.com/AN145.aspx + he AN145-1 Screw-in On/OFF Module is a transceiver which is a Z-Wave TM enabled device and is fully compatiable with any Z-WAVE TM enabled network. The Plug type of AN145-1 is E26 + Lamp Holder + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/33/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/34/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/207/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/214/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/215/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/274/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/276/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/895/xml + + AN145-1_Ever_0910 + + + diff --git a/openzwave/everspring/an158.xml b/openzwave/everspring/an158.xml new file mode 100644 index 00000000..2a24511c --- /dev/null +++ b/openzwave/everspring/an158.xml @@ -0,0 +1,47 @@ + + + http://www.openzwave.com/device-database/0060:0002:0004 + images/everspring/an158.png + https://products.z-wavealliance.org/products/871/ + ON/OFF Plug with power metering + CEPT (Europe) / Russia + http://www.everspring.com/AN158.aspx + This wireless plug-in ON/OFF Module is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave enabled networks. Remote On/Off control of the connected load is possible with other manufacturer’s Wireless Controller. Each module is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. The plug-in ON/OFF Module is compatible with Everspring’s Motion Detectors SP814 and Door/Window Detectors SM103. + AN158-A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/213/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/639/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/871/xml + + http://www.everspring.com.tw/contact-us/index.asp + + + + + + This is the time the switching status needs to remain +unchanged after a change to cause the device to send out a status +message. 0 is Disabled. + + + + + Enable or Disable Send Basic Command to Group 2 when the local +button press changes the switching state. + + + + + The device will report its meter value within the interval +set. Set to 0 will disable the autoreporting function. + + + + + + + + + + + diff --git a/openzwave/everspring/an163.xml b/openzwave/everspring/an163.xml new file mode 100644 index 00000000..47960d3c --- /dev/null +++ b/openzwave/everspring/an163.xml @@ -0,0 +1,51 @@ + + + http://www.openzwave.com/device-database/0060:0005:0004 + images/everspring/an163.png + https://products.z-wavealliance.org/products/979/ + On/Off Plug with metering + AN163-1 + U.S. / Canada / Mexico + This plug-in ON/OFF Module is able to detect current wattage (5~1440W) and overload wattage (1460~1580W) of connected non-dimmable lights or appliances. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/979/xml + + + + + + + This is the time the switching status needs to remain unchanged after a change to cause the device to send out a status message. 0 is Disabled. + + + + + Enable or Disable Send Basic Command to Group 2 when the local button press changes the switching state. + + + + + + + The device will report its meter value within the interval set. + Set to 0 will disable the autoreporting function. + + + + + The device will report its meter value within the interval set. + Set to 0 will disable the autoreporting function. + + + + + + + + + + + diff --git a/openzwave/everspring/an179.xml b/openzwave/everspring/an179.xml new file mode 100644 index 00000000..f1a2337f --- /dev/null +++ b/openzwave/everspring/an179.xml @@ -0,0 +1,61 @@ + + + http://www.openzwave.com/device-database/0060:0008:0004 + images/everspring/an179.png + https://products.z-wavealliance.org/products/1058/ + The In-Wall On/Off Module is a Z-Wave enabled device which is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave enabled networks. Inclusion of this unit on other manufacturer’s Wireless Controller menu allows remote operation of the unit and the connected load. Z-Wave node in the system also acts as a repeater, so the RF signal can reach its intended receiver by routing around obstacles and radio dead spots. + +The In-Wall On/Off Module is designed to control the on/off status of lighting and appliances load in your house. Two sets of dry contacts provide more wiring applications. For security, the unit can detect overheating and will turn off relay automatically to avoid damage. At 230V voltage, this module can support up to 2500W resistive, 1200W incandescent, 700W motor, or 320W (40W*8) fluorescent load. + + NR + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1058/Manual_AN179_20140808.pdf + 1. Put the Z-Wave Controller into inclusion mode. +2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. + + CEPT (Europe) + 1. Put the Z-Wave Controller into exclusion mode. +2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. + + In-Wall On/Off Switch Module + AN179-0 + (This procedure should only be used when the primary controller is no longer operational.) +1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. +2. Within 1 second of step 1, press link key again and hold until LED is off (about 5 sec.). +3. Node ID is excluded, and the unit is returned to the factory default state. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1058/xml + + + + + + + Basic Set Command value + + + + The delaying time to report to Group 1 + + + + + Remember the last status on plug + + + + + + + 0: Single Pole Double Throw (1: Toggle switch) + + + + + + + + + + + diff --git a/openzwave/everspring/an180.xml b/openzwave/everspring/an180.xml new file mode 100644 index 00000000..4e567350 --- /dev/null +++ b/openzwave/everspring/an180.xml @@ -0,0 +1,54 @@ + + + http://www.openzwave.com/device-database/0060:0007:0004 + images/everspring/an180.png + https://products.z-wavealliance.org/products/1456/ + 1. Put the Z-Wave Controller into inclusion mode. +2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. + AN180-2 + on/off mini plug + The On/Off Mini Plug is a Z-WaveTM enabled device which is fully compatible with any Z-WaveTM enabled network. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-WaveTM enabled networks. Inclusion of this unit on other manufacturer’s Wireless Controller menu allows remote operation of the unit and the connected load. + +The On/Off Mini Plug is designed to control the on/off status of appliances load in your house. At 220-240V voltage, this Plug can support up to 1500W resistive. + + NR + 1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. +2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds). +3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes. +4. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + 1. Put the Z-Wave Controller into exclusion mode. +2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1456/Manual_AN180_20150901-A501112261R02-rev.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1066/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1456/xml + + + + + + + Basic Set Command value + + + + The delaying time to report to Group 1 + + + + + Remember the last status on plug + + + + + + + + + + + + + diff --git a/openzwave/everspring/an181.xml b/openzwave/everspring/an181.xml new file mode 100644 index 00000000..21a52441 --- /dev/null +++ b/openzwave/everspring/an181.xml @@ -0,0 +1,72 @@ + + + http://www.openzwave.com/device-database/0060:0006:0004 + images/everspring/an181.png + https://products.z-wavealliance.org/products/1067/ + (This procedure should only be used when the network primary controller is inoperable.) +1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. +2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds). (Please refer to the documentation for the location of the link key.) +3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes.. + Metering Mini Plug + NR + 1. Put the Z-Wave Controller into inclusion mode. +2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. (Please refer to the documentation for the location of the link key.) + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1067/manual_AN181_20140729.pdf + 1. Put the Z-Wave Controller into exclusion mode. +2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. (Please refer to the documentation for the location of the link key.) + + AN181-6 + CEPT (Europe) + The Metering Plug is a Z-Wave enabled device which is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave enabled networks. Inclusion of this unit on other manufacturer’s Wireless Controller menu allows remote operation of the unit and the connected load. + +The Metering Plug is designed to control the on/off status of lighting and appliances load in your house. For metering the unit can detect up to 10485.75kW/h before resetting to 0 and can support wattage, voltage, ampere, and PF detection. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied. At 220-240V voltage, this Plug can support up to 2500W resistive, 1200W incandescent, 700W motor, or 320W (40W*8) fluorescent load. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1067/xml + + + + + + + + Set Basic Set Command value to be sent to group 2 when switch is turned on. + + When the physical button on the mini-plug is used to turn OFF the switch the value "0" will always be sent to group 2, + however this is not the case when the switch is turned off remotely. + + + + + The delaying time to report to Group 1 + + + + + Remember the last status on plug + + + + + + Set the interval for wattage auto report (0 = disabled) + + + Set the interval for kWh auto report (0 = disabled) + + + Auto report is sent when load surpasses the set value of wattage (0 = disabled) + + + Auto report is sent when the change of wattage surpasses the set percentage (0 = disabled) + + + + + + + + + + diff --git a/openzwave/everspring/hac01.xml b/openzwave/everspring/hac01.xml new file mode 100644 index 00000000..8a0007e9 --- /dev/null +++ b/openzwave/everspring/hac01.xml @@ -0,0 +1,22 @@ + + + http://www.openzwave.com/device-database/0116:0001:0010 + images/everspring/hac01.png + https://products.z-wavealliance.org/products/694/ + CEPT (Europe) + Small Z-Wave In-Wall Remote Module + This in-wall remote module is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Mini size design let the module can easily put into the wall box and still have enough space to install the traditional wall switch. There are many application for the module , one application is connect the 2 wire of manual switch input to most of the wall switch sell in the market , while the connected wall switch been switched ON or OFF , the module will send the correspond signal to the associated devices like Z-Wave switch module HAN01 or any Z-Wave ON/OFF or dimmer module。Another application is connect this module to any traditional wire sensor which has NC/NO manual switch input output, and this will easily convert those wire sensors into wireless Z-wave sensors. +With the external antenna let this module have excellent communicate RF range, and this will let the module not only send signal to the associated device by itself easily but also act as a good routing node in the z-wave mesh network. +SM103.HSM02 + +The Module can be connected to resistive load – 2990 watts for U.K. and Denmark, and 3500 watts for Germany, France and Italy. + http://www.everspring.com/HAC01.aspx + HAC01 + http://www.ctc-chromagic.com/?q=contact + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/23/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/694/xml + + + + diff --git a/openzwave/everspring/han01.xml b/openzwave/everspring/han01.xml new file mode 100644 index 00000000..d864263e --- /dev/null +++ b/openzwave/everspring/han01.xml @@ -0,0 +1,20 @@ + + + http://www.openzwave.com/device-database/0060:0001:0011 + images/everspring/han01.png + https://products.z-wavealliance.org/products/695/ + This in-wall switch module is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. +There are many kind of application by using the module to switch AC power On and Off , one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. + +This in-wall switch module is able to detect overload wattage of connected non-dimmable lights or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the wiring of the Module will reset its overload condition to normal status. + + http://www.everspring.com/HAN01.aspx + CEPT (Europe) + HAN01 + Small Z-Wave In-Wall Switch Module + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/695/xml + + + + diff --git a/openzwave/everspring/han02-1.xml b/openzwave/everspring/han02-1.xml new file mode 100644 index 00000000..0d49d485 --- /dev/null +++ b/openzwave/everspring/han02-1.xml @@ -0,0 +1,19 @@ + + + http://www.openzwave.com/device-database/0060:0002:0011 + images/everspring/han02-1.png + https://products.z-wavealliance.org/products/696/ + CEPT (Europe) + http://www.everspring.com/HAN02.aspx + HAN02-1 + Small Z-Wave In-Wall Switch Module With Two Relay + This in-wall switch module is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave enabled networks. Remote On/Off control of the connected load is possible with other manufacturer’s Wireless Controller. + +This in-wall switch module is able to detect overload wattage of connected non-dimmable lights or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the wiring of the Module will reset its overload condition to normal status. +Two additional digital inputs allow user to manual switch on/off the module for normal operation and can manual execute inclusion/exclusion/association at the first 3 minute when the first power is applied, this can let installer easy to configure even the module already install inside the wall box. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/696/xml + + + + diff --git a/openzwave/everspring/hsp02.xml b/openzwave/everspring/hsp02.xml new file mode 100644 index 00000000..39587c2a --- /dev/null +++ b/openzwave/everspring/hsp02.xml @@ -0,0 +1,71 @@ + + + http://www.openzwave.com/device-database/0060:0001:0001 + images/everspring/hsp02.png + https://products.z-wavealliance.org/products/606/ + Malaysia / Hong Kong / CEPT (Europe) / CEPT (Europe) + HSP02 + The motion detector is designed with dual detecting mode: security mode and home automation mode.In security mode, the detector can be used as a security device to detect movements. Z-Wave protocol to secure the success of wireless two way communication +With tamper-proof protection +Easy install and can corner mount +Low battery indication +Very low power consumption (2 years battery life) +Adjustable PIR detection pattern and sensitivity (pet immunity) +Built in light sensor to simulate lighting control + http://www.ctc-chromagic.com/?q=zwave/HSP02 + Chromagic (HSP02) Motion Detector + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/24/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/35/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/392/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/606/xml + + http://www.ctc-chromagic.com/?q=support + + + + + + When Basic Set Command is sent where contains a value, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be. + + + + + The Detecting function can be Disabled of Enabled. + + + + + 1 Means lowest sensitivity and 10 means highest. + + + + + Adjust the interval of being re-triggered afer the detector has been triggered in seconds. + + + + + Sets minimum Lux Level of ambient illumination necessary for Motion Detector to trigger. + + + + + The duration determines how long before the module sends an Off after being triggered. + + + + + + + true + + + + + + + + + + diff --git a/openzwave/everspring/lptdm1u.xml b/openzwave/everspring/lptdm1u.xml new file mode 100644 index 00000000..3d5c6fad --- /dev/null +++ b/openzwave/everspring/lptdm1u.xml @@ -0,0 +1,25 @@ + + + http://www.openzwave.com/device-database/0060:0001:0003 + images/everspring/lptdm1u.png + https://products.z-wavealliance.org/products/1140/ + CEPT (Europe) / Hong Kong / U.S. / Canada / Mexico / CEPT (Europe) / CEPT (Europe) / Russia / U.S. / Canada / Mexico / U.S. / Canada / Mexico / U.S. / Canada / Mexico + AD145-1/ Everspring + The AD145 is a lamp holder to receive the Command from the Controller or Routing Slave and through Controller or Routing Slave controls the ON/OFF status of the plug-in lighting fixtures, of which power loading cannot exceed 20W. + AD145-1 + http://www.everspring.com/AD142.aspx + http://www.everspring.com/AD126.aspx + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/30/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/32/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/208/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/275/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/277/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/870/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/978/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/992/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1140/xml + + + + diff --git a/openzwave/everspring/se812.xml b/openzwave/everspring/se812.xml new file mode 100644 index 00000000..7b657359 --- /dev/null +++ b/openzwave/everspring/se812.xml @@ -0,0 +1,28 @@ + + + http://www.openzwave.com/device-database/0060:0001:000C + images/everspring/se812.png + https://products.z-wavealliance.org/products/735/ + CEPT (Europe) / U.S. / Canada / Mexico / Australia / New Zealand / U.S. / Canada / Mexico + http://www.everspring.com/SE812.aspx + TSE07-1 + Everspring TSE07-1 Indoor Siren + http://www.everspring.com/SE812.aspx + Z-WAVE INDOOR SIREN (US) 300 SERIES + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/273/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/584/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/616/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/735/xml + + + + + + + + + + + diff --git a/openzwave/everspring/sf812.xml b/openzwave/everspring/sf812.xml new file mode 100644 index 00000000..e7f2d099 --- /dev/null +++ b/openzwave/everspring/sf812.xml @@ -0,0 +1,26 @@ + + + http://www.openzwave.com/device-database/0060:0001:000D + images/everspring/sf812.png + https://products.z-wavealliance.org/products/618/ + http://www.everspring.com/SF812.aspx + SF812-ANZ + Smoke Detector + CEPT (Europe) / Australia / New Zealand + The photoelectric Smoke Detector is a Z-Wave enabled device which is fully compatible with any Z-Wave enabled network. + +The detector is designed to sense smoke that comes into the detector chamber. It does not sense gas, heat, or flame. The working principle is when the smoke detector detects a certain density of smoke, the horn of smoke detector will sound and in the meantime, the detector will emit the signals to the associated devices for further execution. It can provide precious time for you and your family to escape before a fire spreads. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/272/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/618/xml + + + + + + + + + + diff --git a/openzwave/everspring/sm103.xml b/openzwave/everspring/sm103.xml new file mode 100644 index 00000000..b81eecb9 --- /dev/null +++ b/openzwave/everspring/sm103.xml @@ -0,0 +1,56 @@ + + + http://www.openzwave.com/device-database/0060:0001:0002 + images/everspring/sm103.png + https://products.z-wavealliance.org/products/924/ + SM103 + Door/Window Sensor + http://www.everspring.com/SM103.aspx + CEPT (Europe) / Russia / CEPT (Europe) + The Mini Door/Window contact detector consists of two parts; a Detector and a Magnet. They are designed to be fitted to doors or windows with the Magnet mounted on the opening part and the Detector mounted on the fixed frame. Opening the protected door/window will remove the magnetic field, trigger the Detector and generate an alarm condition, (if the system is armed). +The Door/Window Detector is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. +If several windows need to be protected, adopt the wire according to the placement as mentioned below. This should be wired to the terminal block provided in the battery compartment in series connection. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/394/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/921/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/924/xml + + + + + + + Defines the level in the event sent when the sensor is triggered. Default is 99 (full brightness for a Z-Wave dimmer). 100-127 will set device on to the last value it was when turned off. + + + + + On Time sets the number of seconds the sensor stays alerted before the off event is sent. + + + + + Enable/Disable power saving mode. 0 enables. + + + + + + + true + + + + + + false + + + + + + + + + diff --git a/openzwave/everspring/sp103.xml b/openzwave/everspring/sp103.xml new file mode 100644 index 00000000..1f4f0e83 --- /dev/null +++ b/openzwave/everspring/sp103.xml @@ -0,0 +1,52 @@ + + + http://www.openzwave.com/device-database/0060:0001:0101 + images/everspring/sp103.png + https://products.z-wavealliance.org/products/873/ + CEPT (Europe) + SP103 + The Motion Detector is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave enabled networks. This Motion Detector is controllable to our modules, such as On/Off Module AN135 and Lamp Module AD130. Inclusion of this Motion Detector on other manufacturer’s Wireless Controller menu allows remote turn-on of connected modules and their connected lighting when the Detector is triggered. Z-Wave nodes in the system also act as repeaters if they support that function. + Motion Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/873/xml + + + + + + + Phase Level of ON Command + The Configuration parameter that can be used to adjust the phase level of ON command is transmitted is Configuration Parameter # 1. + This parameter can be configured with the value of 0 through 127. + Value 0: Set Device OFF(0x00) + Value 1-99: Set Device On (1-99) + Value 100-127: Set Device On to the last phase (0xFF) + Note: 0xFF means the device will be on to the last phase before the device was turned off. + Information reproduced from: http://www.techstyleuk.co.uk/index_files/sp103_manual.pdf + + + + + Enabling/Disabling Power Saving Function (for testing) + When no movement has been detected for 10 seconds, the SP103 will enter the power saving mode. + It can be disabled or enabled power saving function by setting Configuration Parameter # 3. + This parameter can be configured with the value of 0 through 127, where 0 means power saving being enabled and others mean power saving being disabled. + PS : As long as the batteries have been refitted, the Detector will enable the power saving function automatically. + Information reproduced from: http://www.techstyleuk.co.uk/index_files/sp103_manual.pdf + + + + + + true + + + + + + + + + + + diff --git a/openzwave/everspring/sp814.xml b/openzwave/everspring/sp814.xml new file mode 100644 index 00000000..3de25455 --- /dev/null +++ b/openzwave/everspring/sp814.xml @@ -0,0 +1,80 @@ + + + http://www.openzwave.com/device-database/0060:0002:0001 + images/everspring/sp814.png + https://products.z-wavealliance.org/products/977/ + U.S. / Canada / Mexico / CEPT (Europe) / Australia / New Zealand / U.S. / Canada / Mexico + PIR Sensor + The Motion Detector is designed with two detecting sensors, Passive Infra-Red (PIR) sensor and light sensor, to detect movement within a protected area, operating at 868.42 , 908.42, and 921.42 MHz. + +The detector can be used as a security device or home automation device. When the detector is cooperated with security appliances, the detector is acting as a security device by detecting changes in infra-red radiation levels. If a person moves within or across the devices field of vision, a trigger radio signal will be transmitted to cause full alarm condition in order to frighten intruders away. Alternatively, when the detector is worked with Z-Wave Controller , the detector can be set to perform the role of home automation device by detecting both changes in infra-red radiation levels and percentage of lux levels. Once night falls, the percentage of ambient illumination is lower than preset value. If a person moves within or across the devices field of vision, a trigger radio signal will be transmitted so as to turn connected lightings for better illumination. + +Two mounting methods are provided for varying detection range. The detector can be mounted on a wall for farther detecting distance but narrower coverage; while for ceiling mounting, shorter detecting distance can be made but desired coverage can be expected at user’s disposal. + + SP814-2 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/216/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/617/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/977/xml + + http://www.everspring.com/SP814.aspx + http://www.everspring.com/SP814.aspx + + + + + + When Basic Set Command is sent where contains a value, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be. + + + + The Detecting function can be Disabled of Enabled. + + + + + 1 Means lowest sensitivity and 10 means highest. + + + + + + + + + + + + + + Adjust the interval of being re-triggered afer the detector has been triggered in seconds. + IMPORTANT: Parameter size is 1 5-127 or 2 if value > 127. Any value below 127 will be rejected! + + + + + Sets minimum Lux Level of ambient illumination necessary for Motion Detector to trigger. + + + + + The duration determines how long before the module sends an Off after being triggered. + IMPORTANT: Parameter size is 1 5-127 or 2 if value > 127. Any value below 127 will be rejected! + + + + + + + true + + + + + + + + + + diff --git a/openzwave/everspring/sp815.xml b/openzwave/everspring/sp815.xml new file mode 100644 index 00000000..63920efa --- /dev/null +++ b/openzwave/everspring/sp815.xml @@ -0,0 +1,76 @@ + + + http://www.openzwave.com/device-database/0060:0004:0001 + images/everspring/sp815.png + https://products.z-wavealliance.org/products/3366/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3366/SP815 user manual_05102019-A501112752R01.pdf + CEPT (Europe) + 1. Put the Z-Wave Controller into inclusion mode. +2. Press the learn key 3 times within 1.5 seconds to put the unit into inclusion mode. + + After it has been included into a Z-Wave network, the detector will go to sleep but will send a Wakeup Notification Command periodically at preset period to the controller. The Motion detector will stay awake for 10 seconds at least and then go back to sleep to conserve battery life. + +The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class based on the range values below: + +Minimum Wake Up Interval 600s (10 minutes) +Maximum Wake Up Interval 86400s (1 day) +Default Wake Up Interval 14400s (4 hours) +Wake Up Interval Step Seconds 600s (10 minutes) + + 1. Press the learn key 3 times within 1.5 seconds to put the unit into exclusion mode. +2. Within 1 second of step 1, press the learn key again and hold for 5 seconds. +3. Node ID is excluded. The device reverts to factory default state. +(This procedure should only be used when the controller is inoperable.) + 1. Put the Z-Wave Controller into exclusion mode. +2. Press the learn key 3 times within 1.5 seconds to put the unit into exclusion mode. + + The SP815 is a multifunction device with motion detector and temperature/humidity sensor. It uses Passive Infra-Red (PIR) technology to detect movement in a protected area by sensing the changes of thermal radiation caused by the moving body within or across the field of detection. Featuring dual PIR sensor designed with dual lens technology, this detector is immune to presence of pets in the home allowing your pet to move freely without causing false alarms. + +This product is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled network. The device can be set up in a Z-Wave network to communicate directly with other end devices such as smartplugs, or to report directly to a Z-Wave controller (usually a gateway). + +When the motion detector is triggered, an alarm signal will be emitted to the controller and the controller, after receiving the signal, will perform certain action according to its settings. + +The product has a built in digital temperature sensor and humidity sensor to report environmental condition of the protected area to the controller. + +This product supports the S2 security protocol that uses encrypted Z-Wave Plus messages to communicate to other security-enabled Z-Wave Plus products. A security-enabled Z-Wave Plus Controller must be used in order to fully utilize the security features of this product. + + + SP815-1 + PET IMMUNE PIR MOTION DETECTOR + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3366/xml + + + + + + + + + + The parameter adjusts the sleep period after the detector has been triggered. + No response will be made during this interval if a movement is presented. + Longer re-trigger interval will result in longer battery life. + + + + + This controls how long the connected lighting will stay on after the motion is detected. + This is useful for Group 2 associations where the detector is connected directly to another device such as smartplugs. + + + + + + + true + + + + + + + + + + diff --git a/openzwave/everspring/sp816.xml b/openzwave/everspring/sp816.xml new file mode 100644 index 00000000..ecaae239 --- /dev/null +++ b/openzwave/everspring/sp816.xml @@ -0,0 +1,52 @@ + + + http://www.openzwave.com/device-database/0060:0005:0001 + images/everspring/sp816.png + https://products.z-wavealliance.org/products/3077/ + After it has been included into a Z-wave network, the detector will go to sleep but will send a Wakeup Notification Command periodically at preset period to the controller. The Motion detector will stay awake for 10 seconds at least and then go back to sleep to conserve battery life. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3077/SP816 A501112630R01_20180913.pdf + Outdoor Motion Detector + CEPT (Europe) / U.S. / Canada / Mexico + The SP816 Outdoor Motion Detector is a Z-Wave PlusTM enabled device and is fully compatible with any Z-WaveTM enabled network. The device can be set up in a Z-Wave network to communicate directly with other end devices such as lighting controllers, or to report directly to a Z-Eave controller (usually a gateway). + +This motion detector is primarily designed for outdoor lighting control application. It features a PIR motion detector to detect movement in a protected area and a lux sensor for determining brightness of its surroundings. It comes with a built in timer to set the duration for light turn on. The lux level and the timer can be set through knobs on the device itself. + +If the PIR detects motion when lux level falls below a preset setting, the device will transmit a signal to turn on the outdoor lighting (or indirectly through gateway) and then later turns it off when its timer has elapsed. + +This device can also be used as a basic motion sensor for indoor security application. + + SP816-2 + 1. Put the Z-Wave Controller into exclusion mode. +2. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode. + + + 1. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode. +2. Within 1 second of step 1, press the tamper switch again and hold until LED is off (about 5 seconds). +3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes. +(This procedure should only be used when the controller is inoperable.) + 1.Put the Z-Wave Controller into inclusion mode. +2.Press the tamper switch 3 times within 1.5 seconds to put the unit into inclusion mode. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2656/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3077/xml + + + + + + + true + + + + + + + + + + diff --git a/openzwave/everspring/st812.xml b/openzwave/everspring/st812.xml new file mode 100644 index 00000000..dcd80138 --- /dev/null +++ b/openzwave/everspring/st812.xml @@ -0,0 +1,37 @@ + + + http://www.openzwave.com/device-database/0060:0001:000B + images/everspring/st812.png + https://products.z-wavealliance.org/products/736/ + Z-Wave Flood Sensor (US) 300 Series + TST01-1 + Everspring TST01-1 Flood Detector + CEPT (Europe) / U.S. / Canada / Mexico / U.S. / Canada / Mexico + http://www.everspring.com/ST812.aspx + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/217/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/585/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/736/xml + + + + + + + Defines the level in the Basic Set event sent to group 2 when the sensor is triggered. Default is 99 (full brightness for a Z-Wave dimmer). 0 disables. + + + + + + + + + + + + + true + + + diff --git a/openzwave/everspring/st814.xml b/openzwave/everspring/st814.xml new file mode 100644 index 00000000..8ff88301 --- /dev/null +++ b/openzwave/everspring/st814.xml @@ -0,0 +1,76 @@ + + + http://www.openzwave.com/device-database/0060:0001:0006 + images/everspring/st814.png + https://products.z-wavealliance.org/products/974/ + ST814-2 + The Temperature/Humidity Detector is designed to monitor the current temperature and humidity of ambient environment. The reading of temperature/humidity can be reported to you on a regular base at your disposal. If temperature/humidity reaches set points, the detector will send alerts to associated devices for further execution. The application example will be like this , Step 1 include both ST814 and ON/OFF Z-Wave module (like AN158 or AN157, HAN01…) into a Z-wave controller, Step2 associate ST814 to the ON/OFF Z-Wave module Step3 connect the power wire of the heater or humidifier to the ON/OFF Z-Wave module and this simple 3 step will let user easy to control the temperature or humidity of the room automatically Since sudden temperature/humidity change may cause health problems to people such as elderly or very young children, Temp./Humid. Detector provides you most up-to-date temperature and humidity reading for you to watch your family’s health. + + U.S. / Canada / Mexico / CEPT (Europe) / Russia / CEPT (Europe) / U.S. / Canada / Mexico + http://www.everspring.com/ST814.aspx + Temperature/Humidity Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/271/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/923/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/934/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/974/xml + + http://www.everspring.com.tw/contact-us/index.asp + + + + + + Defines the level in the Basic Set event sent to group 2 when the sensor is triggered. Default is 99 (full brightness for a Z-Wave dimmer). 0 disables. + + + + + Temperature level to trigger when a ON command is sent out. 99 will clear the value. + + + + + Temperature level to trigger when an OFF command is sent out. 99 will clear the value. + + + + + Humidity level to trigger when a ON command is sent out. 99 will clear the value. + + + + + Humidity level to trigger when a OFF command is sent out. 99 will clear the value. + + + + + Sets the auto report time interval. 0 disables. + + + + + Sets the auto report temperature trigger interval. 0 disables. + + + + + Sets the auto report humidity trigger interval. 0 disables. + + + + + + + + + + + + + true + + + diff --git a/openzwave/everspring/st815.xml b/openzwave/everspring/st815.xml new file mode 100644 index 00000000..a181f6ca --- /dev/null +++ b/openzwave/everspring/st815.xml @@ -0,0 +1,63 @@ + + + http://www.openzwave.com/device-database/0060:0001:0007 + images/everspring/st815.png + https://products.z-wavealliance.org/products/975/ + Illumination Sensor + U.S. / Canada / Mexico / CEPT (Europe) / U.S. / Canada / Mexico + http://www.everspring.com/ST815.aspx + The Illumination Sensor is designed to monitor the current illumination of ambient environment. The reading of illumination can be reported to you on a regular base at your disposal. If illumination reaches set points, the sensor will send alerts to associated devices for further execution (such as trigger on connected lightings or remote curtain control). The Illumination Sensor is suitable for use in darkness and outdoor. + ST815-2 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/210/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/975/xml + + + + + + + Defines the level in the Basic Set event sent to group 2 when the sensor is triggered. Default is 99 (full brightness for a Z-Wave dimmer). 0 disables. + + + + + Lux level to trigger when a ON command is sent out. 0 will clear the value. + + + + + Lux level to trigger when an OFF command is sent out. 0 will clear the value. + + + + + Set Lux timer trigger to send an OFF command. 0 will clear the value. + + + + + Sets the auto report time interval. 0 disables. + + + + + Sets the auto report Lux interval. 0 disabled. + + + + + + + false + + + + + + + + + + diff --git a/openzwave/everspring/tse03.xml b/openzwave/everspring/tse03.xml new file mode 100644 index 00000000..1c42702d --- /dev/null +++ b/openzwave/everspring/tse03.xml @@ -0,0 +1,38 @@ + + + http://www.openzwave.com/device-database/0060:0001:0009 + images/everspring/tse03.png + https://products.z-wavealliance.org/products/257/ + TSE03-JOEL + TSE03-JOEL - Z-Wave Bell + Z-Wave Bell (EU) ƒ€“ 300 Series UTSE03A Door Bell Set +Features: +◆Adopt Z-Wave protocol to secure the success of wireless two way communication +◆USB port to download 45 second of high quality voice files +◆Visal and audible alarm indications +◆Low battery indication +◆Small form factor +◆IP44 for the push button +◆Z-Wave V5.02 +◆Consist of TSE03 Doorbell and TAC06 push button + http://www.everspring.com/Contact-Us.aspx + CEPT (Europe) + http://www.everspring.com/UTSE03A.aspx + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/257/xml + + + + + + false + + + + + + + + + diff --git a/openzwave/everspringct/hsm02.xml b/openzwave/everspringct/hsm02.xml new file mode 100644 index 00000000..a0ce4663 --- /dev/null +++ b/openzwave/everspringct/hsm02.xml @@ -0,0 +1,108 @@ + + + http://www.openzwave.com/device-database/0116:0001:0002 + images/everspring/hsm02.png + https://products.z-wavealliance.org/products/607/ + http://www.ctc-chromagic.com/?q=contact + CEPT (Europe) + Magnetic door or window sensor. Z-Wave protocol to secure the success of wireless two way communication +Very small size +With tamper-proof protection +Easy install +Low battery indication +Auto report the open/close status and battery status +Very low power consumption (3 years battery life) + http://www.ctc-chromagic.com/?q=zwave/HSM02 + Chromagic (HSM02) Magnetic Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/14/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/607/xml + + + + + + + When Basic Set Command is sent where contains a value, the receiver will + take it for consideration; for instance, if a lamp module is received the Basic + Set command of which value is decisive as to how bright of dim level of lamp + module shall be. + + + + + The Configuration parameter that can be used to adjust the amount of delay + before the OFF command is transmitted as Configuration Parameter #2. + This parameter can be configured with the value of 0 through 127, where 0 + means send OFF command immediately and 127 means 127 seconds of + delay + + + + + + + + + Magnets to be opened/closed + + + + + + + + Grouping 1, afterward, LED will light up for 1 sec to remind user when HSM02 is triggered due to open or close incidents. + + + + No alarm : There is no alarm to report. + Power applied : Once the power has been applied, Alarm Report Command will be sent to + Nodes in Grouping 1 to confirm the power applied status for HSM02. + Tamper event : Grouping 1, afterward, LED will light up for 1 sec to remind user when HSM02 is + triggered due to open or close incidents. + Low battery : When HSM02 automatically wakes up, it will check the battery usage. When + low battery is detected, Alarm Report Command will be sent to Nodes in + Grouping 1, afterward, LED will light up for 1 sec to remind user when HSM02 is + triggered due to open or close incidents. + + + + + + + + + + + + + The users can also inquire the battery status of the unit by sending + BATTERY_GET command via Z-Wave Controller. Once the unit receives the + command, it will return BATTERY_REPORT command. The unit will send + Battery_Level = 255 (0xFF) command to the Z-Wave Controller to inform that + the unit is in low battery status. + + + + + + + + + + true + + + + + + + + + + + + + + diff --git a/openzwave/evolve/lfm-20.xml b/openzwave/evolve/lfm-20.xml new file mode 100644 index 00000000..30d7bdfe --- /dev/null +++ b/openzwave/evolve/lfm-20.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/0113:3133:5246 + images/evolve/lfm-20.png + https://products.z-wavealliance.org/products/1007/ + Scene Capable Fixture Relay + Evolve LFM-20 + LFM-20 + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1007/xml + + + diff --git a/openzwave/evolve/lrm-as.xml b/openzwave/evolve/lrm-as.xml new file mode 100644 index 00000000..05904ffb --- /dev/null +++ b/openzwave/evolve/lrm-as.xml @@ -0,0 +1,19 @@ + + + + + + + + + By default, the LED on the LRM-AS will turn OFF when the load attached is turned ON. To make the LED turn ON when the load attached is turned ON, set parameter to a value of 0. + + + To change the top of the switch to OFF and the bottom of the switch to ON, set parameter to 1. + + + Set this parameter to 0 to disable load sense. Set this parameter to 1 to enable load sense + + + + diff --git a/openzwave/evolve/lsm-15.xml b/openzwave/evolve/lsm-15.xml new file mode 100644 index 00000000..85e7f5e6 --- /dev/null +++ b/openzwave/evolve/lsm-15.xml @@ -0,0 +1,16 @@ + + + + + + + + + By default, the LED on the LSM-15 will turn OFF when the load attached is turned ON. To make the LED turn ON when the load attached is turned ON, set parameter to a value of 0. + + + To change the top of the switch to OFF and the bottom of the switch to ON, set parameter to 1. + + + + diff --git a/openzwave/evolve/ltm-5.xml b/openzwave/evolve/ltm-5.xml new file mode 100644 index 00000000..d0596bee --- /dev/null +++ b/openzwave/evolve/ltm-5.xml @@ -0,0 +1,73 @@ + + + http://www.openzwave.com/device-database/0113:3033:5457 + images/evolve/ltm-5.png + https://products.z-wavealliance.org/products/155/ + U.S. / Canada / Mexico + LTM-5_1006 + http://www.eguestcontrols.com/products/lighting-devices/ltm-5/ + LTM-5 Wall Mounted Transmitter + +The LTM-5 Wall Mounted Transmitter is a component of the Evolve lighting control system. As it controls no load directly, wire the transmitter anywhere power is available according to the diagram above. Inclusion of the LTM-5 Wall Mounted Transmitter allows remote ON/OFF control and dimming of lights controlled by associated modules. + +This Wall Mounted Transmitter is designed to work with other Evolve enabled devices. Evolve nodes of other types can be included in the network and will also act as repeaters to increase the range of the network. + +Power Requirements +120 VAC, 60 Hz +Specifications +Signal (Frequency) – 908.42 MHz +Range – Up to 100 feet line of sight between the Controller and /or the closest Z-Wave Device. +Z-Wave Version 4.52 +Network Inclusion +Scene – Command Class +Security Compatible + http://www.eguestcontrols.com/products/lighting-devices/lt + LTM-5 - Wall mounted Z-Wave transmitter + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/155/xml + + + + + + Dimmers controlled by this switch will start dimming from their current level. + + + + + In night-light mode the LED on the switch will turn ON when the switch is turned OFF. + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. + + + + + This dimmer will start dimming from its current level. + + + + + Flicker LED while transmitting. + + + + + + How often to poll to keep synchronized with group. + + + Poll only the first node in Group 1. + + + + + + + + + + + diff --git a/openzwave/fakro/arz.xml b/openzwave/fakro/arz.xml new file mode 100644 index 00000000..bea11d9d --- /dev/null +++ b/openzwave/fakro/arz.xml @@ -0,0 +1,16 @@ + + + http://www.openzwave.com/device-database/0085:0002:0002 + images/fakro/arz.png + https://products.z-wavealliance.org/products/677/ + http://www.fakro.com/htmlen/379.php + The ARZ Z-Wave external roller shutters, powered by 12VDC, have been adapted for wireless cooperation with the Z-Wave system. The shutter is designed for FAKRO roof windows and its installation is possible at any time after roof window installation. It is also possible to use the shutter for roof windows of other manufactures. Installed on the outside of the window, the roller shutter constitutes an optimum solution against overheating and provides additional protection of the window e.g. against falling tree branches etc. The roller shutter enables complete blackout and good sound reduction. It is also good protection from glazing excessive cooling during the winter. The roller shutter also means increased security. It has built-in overload protection and can be controlled by using standard Z-Wave controller. + ARZ Z-Wave Roof Window Roller Shutter + ARZ + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/677/xml + + + + diff --git a/openzwave/fakro/zwp10.xml b/openzwave/fakro/zwp10.xml new file mode 100644 index 00000000..a37d0914 --- /dev/null +++ b/openzwave/fakro/zwp10.xml @@ -0,0 +1,19 @@ + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/fakro/zwrs.xml b/openzwave/fakro/zwrs.xml new file mode 100644 index 00000000..74656bfb --- /dev/null +++ b/openzwave/fakro/zwrs.xml @@ -0,0 +1,11 @@ + + + + + + + + + + + diff --git a/openzwave/fakro/zws12.xml b/openzwave/fakro/zws12.xml new file mode 100644 index 00000000..8a2a5cbb --- /dev/null +++ b/openzwave/fakro/zws12.xml @@ -0,0 +1,76 @@ + + + http://www.openzwave.com/device-database/0085:0001:0003 + images/fakro/zws12.png + https://products.z-wavealliance.org/products/105/ + Fakro CHAIN ACTUATOR ZWS12 + http://www.fakro.com/htmlen/376.php + Window opener 12VDCThe ZWS12 and ZW230 chain motors thanks to their small dimensions and suitable force output are ideal for roof window operating, being fully compatible with the Z-Wave system. The motors can be applied in both centre pivot and top hung and pivot roof windows as well as windows of non-standard dimensions. +The maximum chain reach is 24cm for ZWS12 and 36cm for ZW230. The motors are equipped with built-in overload protection which acts as a sensor of correct window closing. + http://www.fakro.com/htmlen/376.php + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/105/xml + + + + + + + + + + + diff --git a/openzwave/fakro/zws230.xml b/openzwave/fakro/zws230.xml new file mode 100644 index 00000000..2cb8fba4 --- /dev/null +++ b/openzwave/fakro/zws230.xml @@ -0,0 +1,65 @@ + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgbs001.xml b/openzwave/fibaro/fgbs001.xml new file mode 100644 index 00000000..4b8b65b2 --- /dev/null +++ b/openzwave/fibaro/fgbs001.xml @@ -0,0 +1,98 @@ + + + + + Input I alarm cancellation delay. Additional delay after an alarm from input IN1 has ceased. The parameter allows you to specify additional time, after which the input no. 1 alarm is cancelled once its violation has ceased. Default 0. + + + Input II alarm cancellation delay. Additional delay after an alarm from input IN1 has ceased. The parameter allows you to specify additional time, after which the input no. 1 alarm is cancelled once its violation has ceased. Default 0. + + + Type of input no. 1, what the input 1 will report if no contact is made. Default 1. + + + + + + + Type of input no. 2, what the input 2 will report if no contact is made. Default 1. + + + + + + + Type of transmitted control frame for association group 1, activated via input IN1. The parameter allows to specify the type of alarm frame or to force transmission of control commands (BASIC_SET). Default 255 - BASIC SET. + + + + + + + + + + Type of transmitted control frame for association group 2, activated via input IN1. The parameter allows to specify the type of alarm frame or to force transmission of control commands (BASIC_SET). Default 255 - BASIC SET. + + + + + + + + + + Value of the parameter specifying the forced level of dimming / opening sun blinds when comes "switch on" / "open" command to devices from association group no. 1. +In the case of alarm frames the alarm priority is specified. Possible parameter settings: (1 to 99) and 255. Value of 255 makes it possible to activate the device when using the Dimmer module it means activating the device and setting it to the previous stored condition, e.g. when Dimmer is set to 30%, then deactivated, and then reactivated using command 255, it will automatically be set to the previous condition, i.e. 30%. Default 255. + + + Value of the parameter specifying the forced level of dimming / opening sun blinds when comes "switch on" / "open" command to devices from association group no. 2. In the case of alarm frames the alarm priority is specified. Possible parameter settings: (1 to 99) and 255. Value of 255 makes it possible to activate the device when using the Dimmer module it means activating the device and setting it to the previous stored condition, e.g. when Dimmer is set to 30%, then deactivated, and then reactivated using command 255, it will automatically be set to the previous condition, i.e. 30%. Default 255. + + + Deactivating transmission of the frame cancelling the alarm or the control frame deactivating the device (Basic). It allows for disabling the deactivation function or the alarm cancellation function for devices associated with the appropriate input of the Fibaro Sensor. NOTE: Information concerning alarm violation or activation commands for devices from association groups are always sent. Default 0. ATTENTION: Information alarm triggered or command enabled for devices with associative groups are always sent. NOTE: Value "Group 1 not sent, Group 2 not sent" is only available in version 2.1 and up + + + + + + + Interval between successive readings of temperature from all sensors connected to the device in seconds. Possible parameter settings: (1 to 255). Default 20. ATTENTION: taking temperature readings from the sensor does not result in sending a temperature condition report to the central hub. + + + Interval between forcing to send report concerning the temperature conditions. The forced report is sent immediately after the next reading of temperature from the sensor, irrespective of the settings of parameter no. 12. Value 0 = Deactivates the function. Default 200. ATTENTION: Frequent sending of temperature condition reports is reasonable when the sensor is located somewhere where can occur rapid changes of ambient temperature. In other cases it is recommended to leave the parameter set to the default value. + + + Insensitiveness to temperature changes. This is the maximum acceptable difference between the last reported temperature and the current temperature taken from the sensor. If the temperatures differ by the set value or more, then a report with the current temperature value is sent to the device assigned to association group no. 3. Intervals between taking readings from sensors are specified by parameter no. 10. Possible parameter settings:0 to 255 [0oC to 16oC] [0 oF to 28.8oF] In order to set the appropriate value of the parameter, the following formula should be used: x = delta T x 16 - for Celsius x = delta T x 80 / 9 - for Fahrenheit x parameter value delta T maximum acceptable temperature gradient in Celsius or Fahrenheit If the value is set to 0, then information about the temperature will be sent every time, immediately once the readings have been taken from the sensor. Default 8. + + + Transmitting the alarm or control frame in "broadcast" mode (i.e. to all devices within range), information sent in this mode is not repeated by the mesh network. Default 0. ATTENTION: If the broadcast mode of information transmission is activated for a given channel, then transmission of information in singlecast mode to devices assigned to the association group of this channel is deactivated. + + + + + + + Enable/Disable scene functionality. The device offers the possibility of sending commands compatible with Command class scene activation. Information is sent to devices assigned to association group no. 3. Default 0. + + + + + + + true + + + + + true + + + + + + + + + + + diff --git a/openzwave/fibaro/fgbs222.xml b/openzwave/fibaro/fgbs222.xml new file mode 100644 index 00000000..54af58d9 --- /dev/null +++ b/openzwave/fibaro/fgbs222.xml @@ -0,0 +1,315 @@ + + + http://www.openzwave.com/device-database/010F:1000:0502 + images/fibaro/fgbs222.png + https://products.z-wavealliance.org/products/3285/ + FGBS-222 + FIBARO Smart Implant allows to enhance the functionality of wired sensors and other devices by adding Z-Wave network communication. +You can connect binary sensors, analog sensors, DS18B20 temperature sensors or DHT22 humidity and temperature sensor to report their readings to the Z-Wave controller. +It can also control devices by opening/closing output contacts independently of the inputs. + +Main features of FIBARO Smart Implant: +- Compatible with any Z-Wave or Z-Wave+ Controller, +- Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption, +- Allows for connecting sensors: + o 6 DS18B20 sensors, + o 1 DHT sensor, + o 2 2-wire analog sensor, + o 2 3-wire analog sensor, + o 2 binary sensors. +- Works as a Z-Wave signal repeater, +- Built-in temperature sensor. + + To remove the device from the Z-Wave network: +1. Power the device. +2. Set the main controller into remove mode (see the controller’s manual). +3. Quickly, triple click button on the device housing or switch connected to IN1 or IN2. +4. LED will start blinking yellow, wait for the removing process to end. +5. Successful removing will be confirmed by the Z-Wave controller’s message. + + FIBARO Smart Implant is powered using DC power supply unit so it is always awake. + Smart Implant + To add the device to the Z-Wave network manually: +1. Power the device. +2. Set the main controller in (Security/non-Security Mode) add mode (see the controller’s manual). +3. Quickly, triple click button on the device housing or switch connected to IN1 or IN2. +4. If you are adding in Security S2 Authenticated, scan the DSK QR code or input the 5-digit PIN code (label on the bottom of the box). +5. LED will start blinking yellow, wait for the adding process to end. +6. Successful adding will be confirmed by the Z-Wave controller’s message. + +To add the device to the Z-Wave network using Smart Start: +1. Set the main controller in Security S2 Authenticated add mode (see the controller’s manual). +2. Scan the DSK QR code or input the 5-digit PIN code (label on the bottom of the box). +3. Power the device. +4. LED will start blinking yellow, wait for the adding process to end. +5. Successful adding will be confirmed by the Z-Wave controller’s message. + + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3285/FGBS-222-EN-T-v1.2c.pdf + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. + +Resetting the device is not the recommended way of +removing the device from the Z-Wave network. Use this procedure only when the network primary controller is missing or inoperable. Certain device removal can be achieved by the procedure of removing described. + +1. Press and hold the button to enter the menu. +2. Release button when the device glows yellow. +3. Quickly click the button to confirm. +4. After few seconds the device will be restarted, which is signalled with the red colour. + + + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3195/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3285/xml + + + + + + + + This parameter allows to choose mode of 1st input (IN1). + Change it depending on connected device. + + + + + + + + + + + This parameter allows to choose mode of 2nd input (IN2). + Change it depending on connected device. + + + + + + + + + + + This parameter allows reversing operation of IN1 and IN2 inputs without changing the wiring. + Use in case of incorrect wiring. + + + + + + + This parameter allows reversing operation of OUT1 and OUT2 inputs without changing the wiring. + Use in case of incorrect wiring. + + + + + + + This parameter defines which actions result in sending scene ID and attribute assigned to them. + Parameter is relevant only if parameter 20 is set to 2 or 3. bitmask. + 0 => No scenes sent. + 1 => Key pressed 1 time. + 2 => Key pressed 2 times. + 4 => Key pressed 3 times. + 8 => Key hold down and key released. + + + + + This parameter defines which actions result in sending scene ID and attribute assigned to them. + Parameter is relevant only if parameter 21 is set to 2 or 3. bitmask. + 0 => No scenes sent. + 1 => Key pressed 1 time. + 2 => Key pressed 2 times. + 4 => Key pressed 3 times. + 8 => Key hold down and key released. + + + + + This parameter defines value sent to devices in 2nd association group when IN1 input is triggered (using Basic Command Class). + Available settings: 0-255. + Default setting: 255. + + + + + This parameter defines value sent to devices in 2nd association group when IN1 input is deactivated (using Basic Command Class). + Available settings: 0-255. + Default setting: 255. + + + + + This parameter defines value sent to devices in 3rd association group when IN2 input is triggered (using Basic Command Class). + Available settings: 0-255. + Default setting: 255. + + + + + This parameter defines value sent to devices in 3rd association group when IN2 input is deactivated (using Basic Command Class). + Available settings: 0-255. + Default setting: 255. + + + + + This parameter defines the inertia time of IN1 input in alarm modes. + Adjust this parameter to prevent bouncing or signal disruptions. + Parameter is relevant only if parameter 20 is set to 0 or 1 (alarm mode). + Available settings: 1-100 (10ms-1000ms, 10ms step). + Default setting: 10 (100ms). + + + + + This parameter defines the inertia time of IN2 input in alarm modes. + Adjust this parameter to prevent bouncing or signal disruptions. Parameter is relevant only if parameter 21 is set to 0 or 1 (alarm mode). + Available settings: 1-100 (10ms-1000ms, 10ms step). + Default setting: 10 (100ms). + + + + + This parameter defines additional delay of cancelling the alarm on IN1 input. + Parameter is relevant only if parameter 20 is set to 0 or 1 (alarm mode). + Available settings: + 0 - no delay. + 1-3600s. + Default setting: 0 (no delay). + + + + + This parameter defines additional delay of cancelling the alarm on IN2 input. + Parameter is relevant only if parameter 21 is set to 0 or 1 (alarm mode). + Available settings: + 0 - no delay. + 1-3600s. + Default setting: 0 (no delay). + + + + This parameter defines logic of OUT1 output operation. + + + + + This parameter defines logic of OUT2 output operation. + + + + + + This parameter defines time after which OUT1 will be automatically deactivated. + Available settings: + 0 - auto off disabled. + 1-27000 (0.1s-45min, 0.1s step). + Default setting: 0 (auto off disabled). + + + + + This parameter defines time after which OUT2 will be automatically deactivated. + Available settings: + 0 - auto off disabled. + 1-27000 (0.1s-45min, 0.1s step). + Default setting: 0 (auto off disabled). + + + + + This parameter defines minimal change (from the last reported) of + analog input value that results in sending new report. Parameter is + relevant only for analog inputs (parameter 20 or 21 set to 4 or 5). + Available settings: + 0 - (reporting on change disabled). + 1-100 (0.1-10V, 0.1V step). + Default setting: 5 (0.5V). + + + + + This parameter defines reporting period of analog inputs value. + Periodical reports are independent from changes in value (parameter 63). Parameter is relevant only for analog inputs (parameter + 20 or 21 set to 4 or 5). + Available settings: + 0 (periodical reports disabled). + 60-32400 (60s-9h). + Default setting: 0 (periodical reports disabled). + + + + + This parameter defines minimal change (from the last reported) + of internal temperature sensor value that results in sending new + report. + Available settings: + 0 - (reporting on change disabled). + 1-255 (0.1-25.5C). + Default setting: 5 (0.5C). + + + + + This parameter defines reporting period of internal temperature + sensor value. Periodical reports are independent from changes in + value (parameter 65). + Available settings: + 0 (periodical reports disabled). + 60-32400 (60s-9h). + Default setting: 0 (periodical reports disabled). + + + + + This parameter defines minimal change (from the last reported) of + external sensors values (DS18B20 or DHT22) that results in sending new + report. Parameter is relevant only for connected DS18B20 or DHT22 + sensors. + Available settings: + 0 - (reporting on change disabled). + 1-255 (0.1-25.5 units). + Default setting: 5 (0.5 units) + + + + + This parameter defines reporting period of analog inputs value. + Periodical reports are independent from changes in value (parameter 67). + Parameter is relevant only for connected DS18B20 or DHT22 sensors. + Available settings: + 0 - (periodical reports disabled). + 60-32400 (60s-9h). + Default setting: 0 (periodical reports disabled). + + + + + + true + + + + + true + + + + + + + + + + + diff --git a/openzwave/fibaro/fgcd001.xml b/openzwave/fibaro/fgcd001.xml new file mode 100644 index 00000000..1b694781 --- /dev/null +++ b/openzwave/fibaro/fgcd001.xml @@ -0,0 +1,217 @@ + + + http://www.openzwave.com/device-database/010F:1000:1201 + images/fibaro/fgcd001.png + https://products.z-wavealliance.org/products/2336/ + FIBARO CO Sensor + The CO Sensor needs to be woken up to receive information about the new configuration from the Z-Wave controller, like parameters and associations. To wake up the sensor manually click the button located on the casing. + FGCD-001 + 1) Press and hold the button. +2) Release the button when LED indicator glows white. +3) Click the button when LED indicator glows yellow. +4) After few seconds the device will be reset (confirmed by red LED indicator). + +Resetting the device is not the recommended way of removing the device from the Z-Wave network. use the reset procedure only if the primary controller is missing or inoperable. + + 1) Place the device within direct range of the Z-Wave controller. +2) Set the main Z-Wave controller in (security/non-security) adding mode (see the controller’s manual). +3) Quickly, triple click the button located on the casing. +4) Wait for the device to be added into the system. +5) Successful adding will be confirmed by the Z-Wave controller’s message. + + 1) Place the device within direct range of the Z-Wave controller. +2) Set the main Z-Wave controller in remove mode (see the controller’s manual). +3) Quickly, triple click the button located on the casing. +4) Wait for the removing process to end. +5) Successful removing will be confirmed by the Z-Wave controller’s message. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3000/FGCD-001-EN-T-v1.1.pdf + CEPT (Europe) + FIBARO CO Sensor is an ultra-light, compact, battery-powered carbon monoxide detector, designed to be placed on a wall. Its high sensitivity allows to detect the presence of the carbon monoxide (CO) gas at the early stage in order to prevent carbon monoxide poisoning. Alarm is signalled with a built-in siren, blinking LED indicator and by sending commands to Z-Wave network devices. Additionally, the device is equipped with a temperature sensor. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2336/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3000/xml + + https://products.z-wavealliance.org/products/3000/ + CEPT (Europe) + FGCD-001 + + + + + + + + This parameter allows to set the actions which result in sending notifications to the Z-Wave network controller. + + + + + + + + + This parameter allows to set the actions which result in LED diode indications. + 0=All actions disabled. + 1=Tampering (opened casing). + 2=Exceeding the temperature. + 4=Lack of Z-Wave range. + This parameter does not apply to the most important actions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm. + NOTE: Parameter 3 values may be combined, e.g. 1+2+4=7 means that all actions will be active. + + + + + This parameter allows to set the actions which result in acoustic signals. + 0=All actions disabled. + 1=Tampering (opened casing). + 2=Exceeding the temperature. + 4=Lack of Z-Wave range. + This parameter does not apply to the most important actions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm. + NOTE: Parameter 4 values may be combined, e.g. 1+2+4=7 means that all actions will be active. + + + + + Parameter defines how commands are sent in specified association groups: as secure or non-secure. + Parameter is active only in Z-Wave network security mode. + It does not apply to 1st Lifeline association group. + Available settings: + 0 - all groups sent as non-secure + 1 - 2nd group sent as secure. + 2 - 3rd group sent as secure. + 4 - 4th group sent as secure. + 8 - 5th group sent as secure. + 16 - 6th group sent as secure. + 32 - 7th group sent as secure. + Default setting: 63. + NOTE Parameter 7 values may be combined, e.g. 1+2=3 means that 2nd and 3rd group are sent as secure. + + + + This parameter defines which frames will be sent in the 2-nd Association Group (CO ALARM). + + + + + + This parameter defines the value of BASIC ON command sent to devices in 2nd association group after the CO Alarm activation. + + + This parameter defines the value of BASIC OFF command sent to devices in 2nd association group after the CO Alarm cancellation. + + + + This parameter defines commands sent to devices associated in 4th association group (CO Level). + Values of specified commands may be set in parameters 16 and 19. + + + + + + + + This parameter defines the minimum level of CO concentration whichexceeding will result in starting the timer set in parameter 15. + Available settings: 20 - 400 CO concentration level in ppm + + + + + This parameter defines the time during which the level of CO concentration should remain above the value set in parameter 14 to send the BASIC ON command to 4th association group. + Available settings: 0 - immediate sending of BASIC ON command 1-2880 (30s - 24h, in 30s steps) + Default setting: 0 + + + + + This parameter defines the value of BASIC ON command sent to devices in 4th association group after exceeding the CO level set in parameter 14 through the time set in parameter 15. + Available settings: 0-99 or 255. + Default setting: 255 (turn on) + + + + + This parameter defines the level of CO concentration below which falling will result in sending the BASIC OFF command to 4th association group. + Available settings: 10-400 - CO concentration level in ppm. + Default setting: 25 (25 ppm) + + + + + This parameter defines the time during which the level of CO concentration should remain below the value set in parameter 17 to send the BASIC OFF command to 4th association group. + Available settings: 0 - immediate sending of BASIC OFF command 1-2880 (30s - 24h, in 30s steps) + Default setting: 0 + + + + + This parameter defines the value of BASIC OFF command sent to devices in 4th association group after falling below the CO level set in parameter 17. + Available settings: 0-99 or 255 + Default setting: 0 (turn off) + + + + + Time interval (in seconds) between consecutive reports of temperature (done by built-in temperature sensor). + Short time interval means more frequent communication, which results in shortened battery life. + Available settings: 0 - no periodical reports 10-1440 (5min - 12h, in 30s steps) + Default setting: 0 + + + + + This parameter defines a minimum change in temperature resulting in a report being sent to the main Z-Wave controller. + Available settings: 1-20 (0.5C - 10C, each 0.5C) + Default setting: 2 (1C) P + + + + This parameter defines the temperature level, which exceeding will result in sending actions set in parameters 2, 3 and 4. + Available settings: 1-85 (1C - 85C, each 1C) + Default setting: 55 (55C) + + + + This parameter activates reporting the value of CO concentration level to the main Z-Wave controller. + + + + This parameter defines a minimum change in CO concentration level which results in sending a new value to the main Z-Wave controller. + + + + + + + + + + This parameter defines the CO concentration level, which exceeding will result in sending a new value to the main Z-Wave controller, according to parameter 25 settings. + Adjusting the value allows to get the accurate data in case of danger and helps to save the battery in normal conditions. + Available settings: 10-255 (ppm) + Default setting: 30 (30 ppm) + + + + + + + true + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgd211.xml b/openzwave/fibaro/fgd211.xml new file mode 100644 index 00000000..9a2d50f5 --- /dev/null +++ b/openzwave/fibaro/fgd211.xml @@ -0,0 +1,110 @@ + + + + + + + + Enable/Disable ALL ON/OFF. Default 255. + + + + + + + Activate/Deactivate association sending for group 1 - Note: Parameter 15 must set to 1 to work properly. Default 0. + + + + + + Key no.2 is not represented by any physical device except of devices on association list. This functionality prevents of lack of reaction on pressing key no.2 through polling devices from association list one by one and checking their actual statuses. Default 1. + + + + + Options for changing parameter 1-99. Default 1. + + + Options for changing parameter 1-255 (10ms - 2,5s). + Default 5. + + + + Options for changing parameter 1-255 (10ms - 2,5s) - 0: this value disables the smooth change in light intensity. Default 1. ATTENTION: value 0 is required for inductive and capacitive devices unsuitable for dimming (e.g. fluorescent lamps, motors, etc...) + + + Options for changing parameter 1-99. Default 1. + + + Options for changing parameter 2-99. Default 99. + + + Options for changing parameter 1-98. Default 2. + + + Binary inputs type configuration. Default 0. + + + + + + Double-click set lighting at 100%. Default 1. + + + + + Saving state before power failure. Default 1. + + + + + The function of 3-way switch provides the option to double key no. 1. The dimmer may control two bi-stable push-buttons or an infinite number of mono-stable push-buttons. Default 0. + + + + + The dimmer communicate the level to the associated devices. Default 0. + + + + + This function allow user to change [On-Off] bi-stable keys (parameter no. 14). Default 0. + + + + + This function will enable decreasing the minimum level of the Dimmer by extending the control impulse.[100 - 170]. By changing the minimum level, the user may completely dim LED bulbs. Not all LED bulbs available on the market have the dimming option. WARNING: Wrong setting of the function may cause incorrect operation of the Dimmer. INFO: THIS PARAMETER IS NOT AVAILABLE IN DEVICE FGD211 v2.1-2.3 + + + Alarm of any type (general alarm, water flooding alarm, smoke alarm: CO, CO2, temperature alarm). + Default 3. + + + + + + + Amount of time the device keeps on flashing after receipt of Alarm Frame (1ms-65535ms). Default 600. + + + Available settings: from 1 to 99 Parameters value changes depending on the dimming level. + + + The device offers the possibility of sending commands compatible with Command class scene activation. Information is sent to devices assigned to association group no. 3. Controllers such as Home Center 2 are able to interpret such commands and based on these commands they activate scenes, to which specific scene IDs have been assigned. The user may expand the functionality of the button connected to inputs S1 and S2 by distinguishing the actions of keys connected to those inputs. For example: double click would activate the scene goodnight and triple click would activate the scene morning. Default 0. + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgd212.xml b/openzwave/fibaro/fgd212.xml new file mode 100644 index 00000000..b9785610 --- /dev/null +++ b/openzwave/fibaro/fgd212.xml @@ -0,0 +1,356 @@ + + + http://www.openzwave.com/device-database/010F:1000:0102 + images/fibaro/fgd212.png + https://products.z-wavealliance.org/products/1729/ + FGD-212 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2836/FGD-212-EN-T-v1.3.pdf + 1) Disconnect the power supply, remove the Dimmer from the wall switch box, than connect the power supply. +2) Locate the B-button on the housing. +3) Click and hold the B-button to enter the menu mode. +4) Release and click the B-button to choose "Device reset" option in the menu that is signalled with the yellow LED indicator colour. +5) After few seconds the device will be restarted, which is signalled with the red LED indicator colour and entering the calibration mode. +Note! Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary controller is missing or inoperable. + + 1) Switch off the mains voltage. +2) Open the wall switch box. +3) Connect the Dimmer in accordance with one of the diagrams attached in the manual. +4) Switch on the mains voltage. +5) Wait for the calibration process to end. Light may blink. The device will be switched off once the process is completed. +6) Set the main Z-Wave controller in add mode (see the controller’s manual). +7) Quickly, three times press the B-button or key connected to the S1 terminal. +8) Wait for the device to be added to system. Successful adding will be confirmed by the controller. +9) Arrange the antenna and close the wall switch box. + + CEPT (Europe) + FIBARO Dimmer 2 can switch or dim connected light source either through radio waves or through the wall switch connected directly to it. Dimmer 2 is equipped with a smart algorithm of light source detection which makes configuration easier and ensures high compatibility of the device. It may be used as a switch with non-dimmable light sources in 3-wire connection. Active power and energy consumption allows to monitor and reduce electricity bills. Dimmer 2 is compatible with any Z-Wave or Z-Wave Plus Controller. + +FIBARO Dimmer 2 +Product Identifier: FGD-212 +Brand Name: FIBARO +Z-Wave Certification Number: ZC10-15090017 +Z-Wave Certification Date: 9/16/2015 +Z-Wave Protocol Implementation Conformance Statement: View Download + +Remotely controlled light dimming module is designed to work with various types of light sources in 2 or 3-wire connection so it can operate with or without neutral lead. FIBARO Dimmer can switch or dim connected light source either through radio waves or through the wall switch connected directly to it. Dimmer 2 is equipped with a smart algorithm of light source detection which makes configuration easier and ensures high compatibility of the device. It may be used as a switch with non-dimmable light sources in 3-wire connection. Active power and energy consumption allows to monitor and reduce electricity bills. Dimmer 2 is compatible with any Z-Wave or Z-Wave Plus Controller. + +As a dimmer it operates under the following loads: +• 230V operated conventional incandescent and halogen light sources +• ELV electronic transformers (12V operated halogen lamps and dimmable LED bulbs) +• MLV ferromagnetic transformers with 12V operated halogen lamps +• dimmable LED bulbs +• dimmable compact fluorescent CFL tube lamps +• supported dimmable light sources with minimal power of 5VA (power factor > 0.5) using FIBARO Bypass FGB-002 + +Without dimming function it may work with: +• compact fluorescent lamps +• fluorescent tube lamps with electronic ballast +• LED bulbs (power factor > 0.7) +• supported light sources with minimal power of 5VA (power factor > 0.5) using FIBARO Bypass FGB-002 + +https://www.youtube.com/watch?v=K35uFXoa5c0 + + FIBARO Dimmer 2 + The FIBARO Dimmer 2 is powered with mains voltage so it is always awake. + 1) Set the main controller in remove mode (see the controller’s manual) +2) Quickly, three times press the B-button or key connected to the S1 terminal. +3) Wait for the device to be removed from the system. Successful removing will be confirmed by the controller. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1348/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1504/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1525/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1729/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1736/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2836/xml + Fix duplicate label https://github.com/OpenZWave/open-zwave/issues/1854 + + https://products.z-wavealliance.org/products/2836/ + U.S. / Canada / Mexico / CEPT (Europe) + FGD-212 + + + + + + Parameter is set automatically during the calibration process. Options for changing parameter 1-98. Default 1. + + + Parameter is set automatically during the calibration process. Options for changing parameter 2-99. Default 99. + + + Virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The Dimmer will set to this value after first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources. Options for changing parameter 1-99. Default 1. + + + This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality. Available settings: 0-255 (0s - 25,5s) + + + Available settings: 1-99 Default: 1 + + + Available settings: 0-255 (0s - 2,55s) Default setting: 1 + + + Available settings: 1-99 Default: 1 + + + Available settings: 0-255 (0s - 2,55s) Default setting: 1 + + + Saving state before power failure. Default 1. + + + + + Available settings: 0 - Function disabled; 1-32767 - time to turn off measured in seconds (1s - 9,1h) Default setting: 0 + + + Enable/Disable ALL ON/OFF. Default 255. + + + + + + + Changing value of this parameter will force the calibration process. + + + + + + This parameter determines operating mode of the Dimmer (automatic/manual settings). + + + + + Function based on the sudden power variation of a specific value, interpreted as a LOAD ERROR. Available settings: 0 - function disabled; 1-99 - percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb) Default setting: 30 + + + Time of delay (in seconds) for power variation detection, interpreted as a LOAD ERROR or OVERLOAD detection (too much power connected to the Dimmer). Available settings: 0 - detection of a burnt out bulb disabled; 1-255 - delay time in seconds; Default setting: 5 + + + If the parameter is active, switching on the Dimmer (S1 single click) will always set this brightness level. Available settings: 0 - function disabled; 1-99 - percentage level of brightness; Default setting: 0 + + + Binary inputs type configuration. Default 0. + + + + + + The value sent to associated devices on single click. + + + + + + + + + Double-click set lighting at 100%. Default 1. + + + + + Parameter determines, which actions will not result in sending frames to association groups. Parameter values may be combined, e.g. 1+2=3 means that associations on switching on or off the Dimmer (single click) will not be sent. +Available settings: 0-31 +0 - all actions send to association groups; +1 - do not send when switching on the Dimmer (single click); +2 - do not send when switching off the Dimmer (single click); +4 - do not send when changing dimming level (holding and releasing); +8 - do not send on double click; +16 - send 0xFF value on double click; +Default setting: 0 + + + Parameter determines, which actions will not result in sending frames to association groups. Parameter values may be combined, e.g. 1+2=3 means that associations on switching on or off the Dimmer (single click) will not be sent. +Available settings: 0-31 +0 - all actions send to association groups; +1 - do not send when switching on the Dimmer (single click); +2 - do not send when switching off the Dimmer (single click); +4 - do not send when changing dimming level (holding and releasing); +8 - do not send on double click; +16 - send 0xFF value on double click; +Default setting: 0 + + + Switch no. 2 controls the Dimmer additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch) + + + + + This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st Lifeline group. Parameter values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure. +Available settings: 0-15 +0 - all groups (II-V) sent as non-secure; +1 - 2nd group sent as secure; +2 - 3rd group sent as secure; +4 - 4th group sent as secure; +8 - 5th group sent as secure; +15 - all groups (II-V) sent as secure; +Default setting: 15 + + + SCENE ID depends on the switch type configurations. Default 0. + + + + + + + + + Forced auto-calibration will set this parameter value to 2. + + + + + + Load control mode recognized during auto-calibration. + + + + + This mode is necessary while connecting non-dimmable light sources. Setting this parameter to 1 automatically ignores brightening/dimming time settings. Forced auto-calibration will set this parameter’s value to 2 + + + + + + Dimmability of the load + + + + + Time required to warm up the filament of halogen bulb. + + + + + + This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc. + + + + + + + + Behaviour of the Dimmer after OVERCURRENT or SURGE + + + + + Correction reduces spontaneous flickering of some capacitive load (e.g. dimmable lEDs) at certain brightness levels in 2-wire installation. In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust time of correction for flickering loads. Available settings: 0 - automatic correction disabled 1-254 - duration of correction in seconds 255 - automatic correction always enabled Default setting: 255 + + + Reaching the defined value will result in turning off the load. Additional apparent power limit of 350VA is active by default. Available settings: 0 - functionality disabled; 1-350 - 1W-350W; Default setting: 250 + + + Response to General Purpose Alarm; Default 3. + + + + + + + Response to Water Flooding Alarm; Default 2. + + + + + + + Response to Smoke, CO or CO2 Alarm; Default 3. + + + + + + + Response to Temperature Alarm; Default 1. + + + + + + + Alarm state may be cancelled earlier, as a result of pressing the switches or sending the Z-Wave command frame. + + + OVERLOAD alarm report (load power consumption too high) + + + + + LOAD ERROR alarm report (no load, load failure, burnt out bulb) + + + + + OVERCURRENT alarm report (short circuit, burnt out bulb causing overcurrent) + + + + + SURGE alarm report (Dimmer output overvoltage) + + + + + OVERHEAT (critical temperature) and VOLTAGE DROP (low voltage) alarm report + + + + + The parameter defines the power level change that will result in a new power report being sent. The value is a percentage of the previous report. Available settings: +0 - power reports disabled; +1-100 (1-100%) - power report threshold; +Default setting: 10 (10%) + + + Parameter 52 defines a time period between consecutive reports. Timer is reset and counted from zero after each report. Available settings: +0 - periodic reports disabled; +1-32767 (1-32767 seconds); +Default setting: 3600 (3600s) + + + Energy level change which will result in sending a new energy report. Available settings: +0 - energy reports disabled; +1-255 (0,01 - 2,55 kWh) - report triggering threshold; +Default setting: 10 (0,1 kWh) + + + The Dimmer may include active power and energy consumed by itself in reports sent to the main controller. + + + + + This parameter defines how to calculate active power. This parameter is useful in a case of 2-wire connection with light sources other than resistive. The parameter is set to 0 after forced auto-calibration. + + + + + + This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level. This parameter works only when parameter 58 has a value other than 0. Available settings: 0-500 (0-500W) - power consumed by the load at the maximum brightness level. Default setting: 0 + + + + + + true + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgdw2.xml b/openzwave/fibaro/fgdw2.xml new file mode 100644 index 00000000..2336063e --- /dev/null +++ b/openzwave/fibaro/fgdw2.xml @@ -0,0 +1,158 @@ + + + http://www.openzwave.com/device-database/010F:1000:0702 + images/fibaro/fgdw2.png + https://products.z-wavealliance.org/products/2181/ + https://products.z-wavealliance.org/products/2279/ + FIBARO Door/Window Sensor 2 + FIBARO Door/Window Sensor 2 is a wireless, battery powered, Z-Wave Plus compatible magnetic contact sensor. Changing the device’s status will automatically send signal to the Z-Wave controller and associated devices. In addition the FIBARO Door/Window Sensor 2 is equipped with a built-in temperature sensor. +Sensor can be used to trigger scenes and wherever there is a need for information about opening or closing of doors, windows, garage doors, etc. Opening is detected by separating the sensor’s body and the magnet. + + FGDW-002 + FGDW-002-1 + 1) Place the Door/Window Sensor 2 within the direct range of your Z-Wave controller. +2) Set the main controller in (security/non-security) add mode (see the controller’s manual). +3) Click the Button at least six times. +4) Quickly, three times press one of the TMP buttons (while the other button is pressed). +5) Wait for the adding process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2181/FGDW-002-EN-T-v0.3.2.pdf + 1) Place the Door/Window Sensor 2 within the direct range of your Z-Wave controller. +2) Set the main controller into remove mode (see the controller’s manual). +3) Quickly, three times press one of the TMP buttons (while the other button is pressed). +4) Wait for the removing process to end. +5) Successful removing will be confirmed by the Z-Wave controller’s message. + + + The Door/Window Sensor 2 needs to be woken up to receive informa¬tion about the new configuration from the controller, like parameters and associations. +1) To wake up the sensor manually, click one of the TMP buttons (while the other button is pressed). + + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. In order to reset the device: +1) Open the cover. +2) Remove the battery. +3) Install the battery while holding both TMP buttons. +4) Release the TMP button within 5 seconds. +5) Visual indicator will blink 3 times to confirm launching of reset procedure. +6) Wait around 30s for the resetting process to end, do not remove the battery. +7) Visual LED indicator will blink 6 times to confirm the reset. + +*Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary controller is missing or inoperable. + CEPT (Europe) + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2181/xml + Add support for US Model. + + + + + + This parameter allows to set in what state is door/window when the magnet is close to the sensor. + + + + + This parameter defines events indicated by the visual LED indicator. + Disabling events might extend battery life. + 0 - no indications + 1 - indication of opening/closing status change (input IN) + 2 - indication of wake up (1 x click or periodical) + 4 - indication of device tampering + + + + This parameter defines how commands are sent in specified association groups: as secure or non-secure. + Parameter is active only in Z-Wave network security mode. It does not apply to 1st group Lifeline + + + + + + + + Parameter defines events which result in sending on/off commands to devices added to the 2nd association group. + These commands are sent alternately to switch the devices on and off. + + + + + + + Value sent to devices in 2nd association group when opening is detected. + The value of 0 turns OFF the device, 255 turns it On. + In case of associating devices allowing smooth control, values 1-99 allow to set an associated device to a specified level. + + + + Value sent to devices in 2nd association group when closing is detected. + The value of 0 turns OFF the device, 255 turns it On. + In case of associating devices allowing smooth control, values 1-99 allow to set an associated device to a specified level. + + + + Time that must elapse from opening to send the command frame to to devices in 2nd association group. + + + Time that must elapse from closing to send the command frame to devices in 2nd association group. + + + Time period after which a tamper alarm will be cancelled. + + + Reporting cancellation of tamper alarm to the controller and 3rd association group. + + + + + This parameter defines how often the temperature will be measured. + The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten. + 0 - temperature measurements disabled + 5-32400 - time in seconds + + + + This parameter defines the change of temperature in comparison with last reported, resulting in temperature report being sent to the main controller. + 0 - temperature reports based on threshold disabled + 1-300 - temperature threshold (0.1-30C, 0.1C step) + + + + This parameter determines how often the temperature reports will be sent to the main controller. + 0 - periodic temperature reports disabled + 5-32400 - time in seconds + + + + The value to be added to the actual temperature, measured by the sensor (temperature compensation). (0.1C steps) + + + + Temperature alarms reported to the Z-Wave controller. + Thresholds are set in parameters 55 and 56. + + + + + + + + If temperature is higher than set value, overheat notification will be sent and high temperature scene will be triggered (if activated). + 0-600 (0-60C, 0.1C step). + + + + If temperature is lower than the set value, underheat notification will be sent and low temperature scene will be triggered (if activated). + 0-599 (0-59.9C, 0.1C step) + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgfs101.xml b/openzwave/fibaro/fgfs101.xml new file mode 100644 index 00000000..bc8d21e2 --- /dev/null +++ b/openzwave/fibaro/fgfs101.xml @@ -0,0 +1,100 @@ + + + + + Flood alarm cancellation delay. Additional delay after a flood alarm has ceased. The parameter allows you to specify additional time, after which the flood alarm is cancelled once its violation has ceased. + + + Acoustic and visual signals in case of flooding. + + + + + + + Type of alarm frame for association group 1, activated by flood sensor. The parameter allows to specify the type of alarm frame or to force transmission of control commands (BASIC_SET) + + + + + Value of the parameter specifying the forced level of dimming / opening sun blinds when comes "switch on" / "open" command to devices from association group no. 1. +In the case of alarm frames the alarm priority is specified. Possible parameter settings: (1 to 99) and 255. Value of 255 makes it possible to activate the device when using the Dimmer module it means activating the device and setting it to the previous stored condition, e.g. when Dimmer is set to 30%, then deactivated, and then reactivated using command 255, it will automatically be set to the previous condition, i.e. 30%. + + + Deactivating transmission of the frame cancelling the alarm or the control frame deactivating the device (Basic). It allows for disabling the deactivation function or the alarm cancellation function for devices associated with the appropriate input of the Fibaro Sensor. NOTE: Information concerning alarm violation or activation commands for devices from association groups are always sent. + + + + + Interval between successive readings of temperature from all sensors connected to the device in seconds. Note: taking temperature readings from the sensor does not result in sending a temperature condition report to the central hub. + + + Insensitiveness to temperature changes. This is the maximum acceptable difference between the last reported temperature and the current temperature taken from the sensor. If the temperatures differ by the set value or more, then a report with the current temperature value is sent to the device assigned to association group no. 3. Intervals between taking readings from sensors are specified by parameter no. 10. +Possible parameter settings:1 to 1000 [each 0.01oC] [0.01oC to 10.00oC]. + + + Transmitting the alarm or control frame in "broadcast" mode (i.e. to all devices within range), information sent in this mode is not repeated by the mesh network. NOTE: If the broadcast mode of information transmission is activated for a given channel, then transmission of information in singlecast mode to devices assigned to the association group of this channel is deactivated. + + + + + + + The parameter stores a temperature value, below which LED indicator blinks with a colour determined by Parameter 61 settings. By default the LED indicator blinks blue. +Possible parameter settings:-10000 to 10000 [each 0.01oC] [-100oC to 100oC]. + + + The parameter stores a temperature value, above which LED indicator blinks with a colour determined by Parameter 62 settings. By default the LED indicator blinks red. +Possible parameter settings:-10000 to 10000 [each 0.01oC] [-100oC to 100oC]. + + + The parameter stores RGB colour value. + + + The parameter stores RGB colour value. + + + Parameter determines LED indicator's operation. Set to 0 turns the indicator off, saving battery life. + + + + + + Parameter stores a temperature value to be added to or deducted from the current temperature measured by the internal temperature sensor in order to compensate the difference between air temperature and the temperature at floor level. +Possible parameter settings:-10000 to 10000 [each 0.01oC] [-100oC to 100oC]. + + + The device is able to turn on alarms resulting from sensors vibrations, e.g. when the sensor is moved, or the TMP button is released. Group 2 association alarms are not cancelled. + + + + + + + Parameter determines a time period after which alarm will become 'quiet' - still active but the device will go into battery saving mode. Visual or acoustic alarm will be reactivated after time period specified in Parameter 76. When alarm status ceases, alarm will be turned off immediately. +Value of 0 means visual and acoustic alarms are active indefinitely. In battery power mode the device will never go to sleep which may shorten battery life significantly. + + + Parameter determines a time period after which an alarm frame will be retransmitted. +Value of 0 cancels an alarm frame retransmission. + + + Allows for turning off the internal flood sensor. Tamper and internal temperature sensors will remain active. + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/fibaro/fgfs101zw5.xml b/openzwave/fibaro/fgfs101zw5.xml new file mode 100644 index 00000000..dd8dee90 --- /dev/null +++ b/openzwave/fibaro/fgfs101zw5.xml @@ -0,0 +1,140 @@ + + + http://www.openzwave.com/device-database/010F:1002:0B01 + images/fibaro/fgfs101zw5.png + https://products.z-wavealliance.org/products/2791/ + 1) Open the cover by turning it counter-clockwise. +2) Make sure the device is powered (either by a battery or a DC power supply). +3) Press and hold the TMP button for 15-20 seconds until LED glows yellow (4th menu position). +4) Release and click the TMP button to start the reset procedure. +5) Successful reset will be confirmed with the LED indicator changing colour to red and an acoustic signal. +Use reset procedure only if the primary controller is missing or inoperable. + + FGFS-101 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3327/FGFS-101-EN-T-v2.11.pdf + FIBARO Flood Sensor will wake up at a defined time interval and will always try to communicate with the main controller. There is a possibility to wake up the device manually by clicking the TMP button + 1) Open the cover by turning it counter-clockwise. +2) Make sure the device is powered (either by a battery or a DC power supply). +3) Place the device within the direct range of your Z-Wave controller. +4) Set the main controller in remove mode (see the controller’s manual). +5) Quickly, triple click the TMP button located inside the casing. +6) Wait for the removing process to end. +7) Successful removing will be confirmed by the Z-Wave controller’s message. + + 1) Open the cover by turning it counter-clockwise. +2) Remove battery blocker. +3) Place the device within the direct range of your Z-Wave controller. +4) Set the main controller in (security/non-security) add mode (see the controller’s manual). +5) Quickly, triple click the TMP button located inside the casing. +6) Wait for the adding process to end. +7) Successful adding will be confirmed by the Z-Wave controller’s message. +8) Close the cover by turning it clockwise. +9) Place the sensor onto a surface prone to flooding. Three electrodes underneath the device should evenly touch the surface. + + FIBARO Flood Sensor is a universal, Z-Wave Plus compatible, flood and temperature sensor. The device can be powered using battery, 12/24V DC power supply or both. Flood alarm is sent to the Z-Wave network devices or additionally to any alarm system controller through opening a NC contact using the external power supply. The device has a built-in temperature sensor that allows to monitor ambient temperature. FIBARO Flood Sensor is designed to be placed on the floor or mounted on a wall (in this case Flood Sensor probes should be extended using addition wire). The device has a built-in visual LED indicator and an acoustic alarm. The LED indicator signals flood, operating mode or the Z-Wave network communication range. In addition, the device is equipped with a sensor reporting tilt or movement to the main controller e.g. when someone has taken the Sensor from its original location. FIBARO Flood Sensor is sink-proof, which means it drifts on the water surface and keeps on sending alarm signal in case of substantial inundation of water (if not wired). Flood Sensor is compatible with any Z-Wave or Z-Wave+ Controller. + CEPT (Europe) + FIBARO Flood Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1354/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1642/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2742/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2791/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3327/xml + + https://products.z-wavealliance.org/products/2742/ + FGFS-101 + U.S. / Canada / Mexico + https://products.z-wavealliance.org/products/3327/ + FGFS-101 + CEPT (Europe) + + + + + Determines time period (in seconds) by which a Flood Sensor will retain the flood state after the flooding itself has ceased. The sensor will keep on reporting flooding to the main controller. This parameter setting does not affect acoustic and visual alarms, which turn off immediately after flooding ceases. + + + Acoustic and visual signals in case of flooding. + + + + + + + Determines the requested "on" level to be sent to devices from 2nd association group upon flood event. + + + This setting decides whether device turn off commands and alarm cancellation notifications will be sent to devices in 2nd and 3rd association groups (respectively) + + + + + Interval between successive readings of temperature from all sensors connected to the device in seconds. Note: taking temperature readings from the sensor does not result in sending a temperature condition report to the central hub. + + + Insensitiveness to temperature changes. This is the maximum acceptable difference between the last reported temperature and the current temperature taken from the sensor. If the temperatures differ by the set value or more, then a report with the current temperature value is sent to the device assigned to association group no. 3. Intervals between taking readings from sensors are specified by parameter no. 10. + Possible parameter settings:1 to 1000 [each 0.01oC] [0.01oC to 10.00oC]. + + + The parameter stores a temperature value, below which LED indicator blinks with a colour determined by Parameter 61 settings. By default the LED indicator blinks blue. + Possible parameter settings:-10000 to 10000 [each 0.01oC] [-100oC to 100oC]. + + + The parameter stores a temperature value, above which LED indicator blinks with a colour determined by Parameter 62 settings. By default the LED indicator blinks red. + Possible parameter settings:-10000 to 10000 [each 0.01oC] [-100oC to 100oC]. + + + The parameter stores RGB colour value. + + + The parameter stores RGB colour value. + + + Parameter determines LED indicator's operation. Set to 0 turns the indicator off, saving battery life. + + + + + + Parameter stores a temperature value to be added to or deducted from the current temperature measured by the internal temperature sensor in order to compensate the difference between air temperature and the temperature at floor level. + Possible parameter settings:-10000 to 10000 [each 0.01oC] [-100oC to 100oC]. + + + The device is able to report tamper alarms resulting from sensor tilt/movement or TMP button state change. + + + + + + + Parameter determines a time period after which alarm will become quiet - still active but the device will go into battery saving mode. Visual or acoustic alarm will be reactivated after time period specified in Parameter 76. When alarm status ceases, alarm will be turned off immediately. + Value of 0 means visual and acoustic alarms are active indefinitely. In battery power mode the device will never go to sleep which may shorten battery life significantly. + + + Parameter determines a time period after which an alarm frame will be retransmitted. + Value of 0 cancels an alarm frame retransmission. + + + Allows for turning off the internal flood sensor. Tamper and internal temperature sensors will remain active. + + + + + This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st Lifeline group. + + + + + true + + + + + + + + + + + + diff --git a/openzwave/fibaro/fggc001.xml b/openzwave/fibaro/fggc001.xml new file mode 100644 index 00000000..655f81ce --- /dev/null +++ b/openzwave/fibaro/fggc001.xml @@ -0,0 +1,260 @@ + + + http://www.openzwave.com/device-database/010F:1000:0D01 + images/fibaro/fggc001.png + https://products.z-wavealliance.org/products/1655/ + CEPT (Europe) + 1) Place the Swipe within the direct range of your Z-Wave controller. +2) Set the main controller in (security/non-security) add mode (see the controller’s manual). +3) Move and hold your hand close to the centre of the pad. +4) If the device is battery powered, high pitched beep will signal exiting the Standby Mode. +5) Loud sound sequence will confirm entering the menu, keep holding your hand. +6) After hearing two short beeps, withdraw the hand and perform swiping up gesture to confirm selection (two beeps will confirm validity). +7) Wait for the adding process to end. +8) Successful adding will be confirmed by the Z-Wave controller’s message and 3 short beeps. + + The Swipe needs to be woken up to receive information about the new configuration from the Z-Wave controller, like parameters and associations. Use 1st menu position to wake up the device or click the button on the back of the device once. + +1) Move and hold your hand close to the center of the pad. +2) Loud sound sequence will confirm entering the menu, keep holding your hand. +3) Wait for the buzzer to indicate the 1st menu position (1 short beep) +4) Withdraw the hand and perform swiping up gesture to confirm selection (two beeps will confirm validity). + + + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. In order to reset the device: +1) Make sure the device is powered. +2) Move and hold your hand close to the center of the pad. +3) Loud sound sequence will confirm entering the menu, keep holding your hand. +4) Wait for the buzzer to indicate the 3rd menu position (3 short beeps) +5) Withdraw the hand and perform swiping up gesture to confirm selection (two beeps will confirm validity). +Resetting the device is not the recommended way of removing the device from the +Z-Wave network. Use the reset procedure only if the primary controller is missing +or inoperable. Certain device removal can be achieved by the procedure of removing +described in "Adding the device" on page 8. + + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1745/FGGC-001-US-T-v1.0.pdf + 1) Place the Swipe within the direct range of your Z-Wave controller. +2) Set the main controller in remove mode (see the controller’s manual). +3) Move and hold your hand close to the centre of the pad. +4) If the device is battery powered, high pitched beep will signal exiting the Standby Mode. +5) Loud sound sequence will confirm entering the menu, keep holding your hand. +6) After hearing two short beeps (green indicator colour), withdraw the hand and perform swiping up gesture to confirm selection (two beeps will confirm validity). +7) Wait for the removing process to end. +8) Successful removing will be confirmed by the Z-Wave controller’s message and sequence of 2 short beeps, pause, 1 short beep. + + FIBARO Swipe is a revolutionary, battery-powered gesture control pad that allows you to control devices through the Z-Wave network. Swipe your hand up, down, left or right in front of the pad, make circular gestures and use sequences of gestures to get full and intuitive control of your smart home. +Installed device perfectly matches your interior design, as it resembles a picture frame. You can even personalize it with your favourite picture. Gesture controlled menu allow to add/remove or reset the device without dismounting it. +The device is equipped with a buzzer that confirms performed gestures and other actions. + + FGGC-001 + FIBARO Swipe + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1655/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1745/xml + + https://products.z-wavealliance.org/products/1745/ + FGGC-001 + U.S. / Canada / Mexico + + + + + + Parameter determines orientation of the Swipe in relation to its default position. + Required for proper gestures recognition. + + + + + + + + Acoustic signalling of gestures detection. + + + + + Visual indication of gestures detection + + + + + + Acoustic signalling of gesture recognition result (using the built-in buzzer). + Note: Parameter 4 is relevant only if parameter 2 is set to Enabled. + + + + + + + + This parameter determines how often the device checks if the USB power supply is connected and updates powering mode if needed. + 0 - powering mode is not updated + 1-1080 (in minutes) - time interval + Default : (4 minutes) + + + + + This parameter determines operation of gesture detection when battery powered. + When Standby Mode is selected, hold gesture must be performed to exit power saving mode and reactivate normal gesture recognition. + The device in Standby Mode consumes the least battery life. + When Simple Mode mode is selected, gesture recognition is always active, but only slowly performed gestures will be recognized properly (high battery consumption). + + + + + + + This parameter allows to choose if the menu can be entered using the Hold gesture + + + + + + Defines which actions result in sending scenes to 1st Lifeline group + 1 - scenes for Flick UP gesture enabled + 2 - scenes for Flick DOWN gesture enabled + 4 - scenes for Flick LEFT gesture enabled + 8 - scenes for Flick RIGHT gesture enabled + 16 - scenes for clockwise circular gesture enabled + 32 - scenes for counter-clockwise circular gesture enabled + Default setting: 15 + + + + + Parameter defines how commands are sent in specified association groups: as secure or non-secure. + Parameter is active only in Z-Wave network security mode. + It does not apply to 1st Lifeline association group. + 1 - 2nd group Flick UP sent as secure + 2 - 3rd group Flick DOWN sent as secure + 4 - 4th group Flick LEFT sent as secure + 8 - 5th group Flick RIGHT sent as secure + 16 - 6th group Circular AirWheel sent as secure + Default setting: 31 + + + + + Parameter allows to choose control mode for 2nd-5th groups and scenes. + By default, Toggle Mode is active, meaning that a single flick turns ON + the group and the same flick turns it OFF, doubled flicks are inactive. + After disabling Toggle Mode a single flick will turn the device ON and the same flick doubled will turn it OFF. + 1 - Toggle Mode enabled for 2nd association group + 2 - Toggle Mode enabled for 3rd association group + 4 - Toggle Mode enabled for 4th association group + 8 - Toggle Mode enabled for 5th association group + Default setting: 15 + + + + + Parameter allows to choose how long the hand has to be held near the center of the pad after AirWheel gesture for the associated devices to reach their maximum/minimum level. + 0-10 - duration in seconds + 255 - default settings of controlled devices + + + + + + This parameter allows to set value sent in switch ON command frame to the association group. + 0-99 or 255 + + + + + This parameter allows to set value sent in switch OFF command frame to the association group. + 0-99 or 255 + + + + + This parameter allows to set value sent in switch ON command frame to the association group. + 0-99 or 255 + + + + + This parameter allows to set value sent in switch OFF command frame to the association group. + 0-99 or 255 + + + + + This parameter allows to set value sent in switch ON command frame to the association group. + 0-99 or 255 + + + + + This parameter allows to set value sent in switch OFF command frame to the association group. + 0-99 or 255 + + + + + This parameter allows to set value sent in switch ON command frame to the association group. + 0-99 or 255 + + + + + This parameter allows to set value sent in switch OFF command frame to the association group. + 0-99 or 255 + + + + + + Parameter activated by the main Z-Wave controller. + Change its value to launch sequence learning procedure for the desired slot. + 0 - learning mode disabled + 1-6 - launch sequence learning for selected slot + + + + + Value containing sequence of gestures. See Sequences of gestures on page 12 for more information. + + + + + Value containing sequence of gestures. See Sequences of gestures on page 12 for more information. + + + + + Value containing sequence of gestures. See Sequences of gestures on page 12 for more information. + + + + + Value containing sequence of gestures. See Sequences of gestures on page 12 for more information. + + + + + Value containing sequence of gestures. See Sequences of gestures on page 12 for more information. + + + + + Value containing sequence of gestures. See Sequences of gestures on page 12 for more information. + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgk001.xml b/openzwave/fibaro/fgk001.xml new file mode 100644 index 00000000..e254aab8 --- /dev/null +++ b/openzwave/fibaro/fgk001.xml @@ -0,0 +1,98 @@ + + + http://www.openzwave.com/device-database/010F:1000:0700 + images/fibaro/fgk001.png + https://products.z-wavealliance.org/products/1050/ + FGK-10x + CEPT (Europe) + FIBARO Door/Window Sensor + Door/Window Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1050/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1077/xml + + https://products.z-wavealliance.org/products/1077/ + FGK10x + U.S. / Canada / Mexico + + + + + Input I alarm cancellation delay. Additional delay after an alarm from input IN1 has ceased. The parameter allows you to specify additional time, after which the input no. 1 alarm is cancelled once its violation has ceased. + + + Status change signalled by LED. Default setting: LED turned On + + + + + Type of input no. 1, what the input 1 will report if no contact is made + + + + + + + Type of transmitted control frame for association group 1, activated via input IN1. The parameter allows to specify the type of alarm frame or to force transmission of control commands (BASIC_SET) + + + + + + + + + + Value of the parameter specifying the forced level of dimming / opening sun blinds when comes "switch on" / "open" command to devices from association group no. 1. + In the case of alarm frames the alarm priority is specified. Possible parameter settings: (1 - 99) and 255. Value of 255 makes it possible to activate the device when using the Dimmer module it means activating the device and setting it to the previous stored condition, e.g. when Dimmer is set to 30%, then deactivated, and then reactivated using command 255, it will automatically be set to the previous condition, i.e. 30%. + + + Deactivating transmission of the frame cancelling the alarm or the control frame deactivating the device (Basic). It allows for disabling the deactivation function or the alarm cancellation function for devices associated with the appropriate input of the Fibaro Sensor. NOTE: Information concerning alarm violation or activation commands for devices from association groups are always sent. + + + + + + Interval between successive readings of temperature from all sensors connected to the device in seconds. Note: taking temperature readings from the sensor does not result in sending a temperature condition report to the central hub. + + + Interval between forcing to send report concerning the temperature conditions. The forced report is sent immediately after the next reading of temperature from the sensor, irrespective of the settings of parameter no. 12. Value 0 = Deactivates the function. Note: Frequent sending of temperature condition reports is reasonable when the sensor is located somewhere where can occur rapid changes of ambient temperature. In other cases it is recommended to leave the parameter set to the default value. + + + Insensitiveness to temperature changes. This is the maximum acceptable difference between the last reported temperature and the current temperature taken from the sensor. If the temperatures differ by the set value or more, then a report with the current temperature value is sent to the device assigned to association group no. 3. Intervals between taking readings from sensors are specified by parameter no. 10. + Possible parameter settings:0 - 255 [0oC to 16oC] [0 oF - 28.8oF] + In order to set the appropriate value of the parameter, the following formula should be used: + x = delta T x 16 - for Celsius + x = delta T x 80 / 9 - for Fahrenheit + x - parameter value + delta T - maximum acceptable temperature gradient in Celsius or Fahrenheit + If the value is set to 0, then information about the temperature will be sent every time, immediately once the readings have been taken from the sensor. + + + Transmitting the alarm or control frame in "broadcast" mode (i.e. to all devices within range), information sent in this mode is not repeated by the mesh network. NOTE: If the broadcast mode of information transmission is activated for a given channel, then transmission of information in singlecast mode to devices assigned to the association group of this channel is deactivated. + + + + + + + Enable/Disable scene functionality. The device offers the possibility of sending commands compatible with Command class scene activation. Information is sent to devices assigned to association group no. 3. + + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/fibaro/fgk10x.xml b/openzwave/fibaro/fgk10x.xml new file mode 100644 index 00000000..83c70327 --- /dev/null +++ b/openzwave/fibaro/fgk10x.xml @@ -0,0 +1,218 @@ + + + http://www.openzwave.com/device-database/010F:2001:0701 + images/fibaro/fgk10x.png + https://products.z-wavealliance.org/products/1620/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1620/FGK-10x-US-T-v1.0.pdf + U.S. / Canada / Mexico + Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary controller is missing or inoperable. + +1) Take off the Sensor's cover and remove battery. +2) Install the battery while holding both TMP buttons (after mounting the device, one button is constantly pressed by the cover). +3) Release the TMP button within 5 seconds. +4) LED will blink 3 times to confirm launching of reset procedure. +5) Reset procedure may last up to 30 seconds. Do not remove the battery until reset is complete. +6) Reset will be confirmed by the six blinks of the LED. + 1) Open the cover. +2) Remove the battery blocker. +3) Close the cover. +4) Locate the sensor nearby the main Z-Wave controller. +5) Set the main Z-Wave controller into adding mode (see main controller’s operating manual). +6) Quickly, triple click the TMP button located on the bottom of the casing. +7) Wait for the device to be added to the system. +8) Successful adding will be confirmed by the controller. +9) Install the device using the attached self-adhesive pads. + + FIBARO Door/Window Sensor is a wireless, battery powered reed sensor compatible with the Z-Wave Plus standard. Changing the device’s status will automatically send signal to the Z-Wave controller and associated devices. +Sensor can be used to trigger scenes and everywhere there is a need for information about opening or closing of doors, windows, garage doors, etc. Opening is detected by separating the sensor’s body and the magnet. +In addition the FIBARO Door/Window Sensor supports one DS18B20 temperature sensor and has one potential free input. + +The FIBARO Door / Window Sensor is available in seven colors: white, silver, black, pearl powder, cappuccino, truffle surprise and dark chocolate. + + +https://www.youtube.com/watch?v=K35uFXoa5c0 + FGK-10X + 1) Place the device within direct reange of the Z-Wave controller. +2) Make sure that Sensor's cover is closed. +3) Set the main Z-Wave controller into learning mode (see main controller’s operating manual). +4) Quickly, triple click the TMP button. +5) Wait for the device to be excluded from the system. Successful exclusion will be confirmed by the controller. + + FIBARO Door/Window Sensor + FIBARO Door/Window Sensor will wake up at a defined time interval and will ALWAYS try to communicate with the main controller. Setting wake up interval to 0 disables sending Wake Up Notification frame automatically. There is a possibility to wake up the device manually by a single TMP button click. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1620/xml + + + + + + Parameter defines device operation mode. + + + + + Parameter defines state of the sensor when the magnet is close. + If you connect the alarm sensor, it determines the output type. + Parameter inactive in Switch Mode (parameter 1 set to 1). + + + + + This parameter defines events indicated by the visual LED indicator. + Disabling events might extend battery life. + 0 - no indications + 1 - indication of opening/closing status change (input IN) + 2 - indication of wake up (1 x click or periodical) + 4 - indication of device tampering + + + + Parameter defines state of the sensor when the magnet is close. + If you connect the alarm sensor, it determines the output type. + Parameter inactive in Switch Mode (parameter 1 set to 1). + + + + + Parameter defines events which result in sending on/off commands to devices added to the 2nd association group. + These commands are sent alternately to switch the devices on and off. + Commands represent the values of BASIC SET command frames. + Parameter is inactive in external button mode (parameter 1 set to 1). + + + + + + Command frames sent to devices added to the 2nd association group. + + + + + + The value of 0 turns OFF the device, 255 turns it ON. + In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an associated device to a specified level. + + + + The value of 0 turns OFF the device, 255 turns it ON. + In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an associated device to a specified level. + + + + Time period after which ON command frame will be sent. + + + + Time period after which OFF command frame will be sent. + + + + Type of control frames transmitted to the main controller and 3rd association group Alarm. + If an external sensor is connected to IN input, it is possible to choose its functionality. + Otherwise it is recommended to set this parameter to default value. + + + + + + + + + Time period after which a tamper alarm will be cancelled. + + + + Reporting cancellation of tamper alarm to the controller and 5th association group. + + + + + This parameter defines how often the temperature will be measured. + The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten. + 0 - temperature measurements disabled + 5-32400 - time in seconds + + + + This parameter defines the change of temperature in comparison with last reported, resulting in temperature report being sent to the main controller. + 0 - temperature reports based on threshold disabled + 1-300 - temperature threshold (0.1-30C, 0.1C step) + + + + This parameter determines how often the temperature reports will be sent to the main controller. + 0 - periodic temperature reports disabled + 5-32400 - time in seconds + + + + The value to be added to the actual temperature, measured by the sensor (temperature compensation). (0,1C steps) + + + + Temperature alarms reported to the Z-Wave controller. + Thresholds are set in parameters 55 and 56. + + + + + + + If temperature is higher than set value, overheat notification will be sent and high temperature scene will be triggered (if activated). + 0-1000 (0-100C, 0.1C step). + + + + If temperature is lower than the set value, underheat notification will be sent and low temperature scene will be triggered (if activated). + 300-700 (-30-70C, 0.1C step) + + + + The device can trigger scenes using scene IDs assigned to different events. + To deactivate all scenes set the value to 0. + To activate all scenes set the value to 3903. + 1 - [ID 10] opening door/window (single click). + 2 - [ID 11] closing door/window (single click). + 4 - [ID 12] holding. + 8 - [ID 13] releasing. + 16 - [ID 14] double click. + 32 - [ID 15] triple click. + 256 - [ID 50] high temperature - door/window opened. + 512 - [ID 50] high temperature - door/window closed. + 1024 - [ID 51] low temperature - door/window opened. + 2048 - [ID 51] low temperature - door/window closed. + + + + Settings for broadcasting ON/OFF commands, sensor alarm and tamper alarm. + Value other than 0 means alarms are sent in Broadcast Mode, to all devices only within the range of the device. + They are not repeated by the mesh network. + 0 - broadcasts inactive. + 1 - ON/OFF commands broadcast active. + 2 - sensor alarm broadcast active. + 4 - tamper alarm broadcast active. + + + + This parameter defines how commands are sent in specified association groups: as secure or non-secure. + Parameter is active only in Z-Wave network security mode. It does not apply to 1st group Lifeline + 0 - none of the groups sent as secure. + 1 - 2nd group Control sent as secure. + 2 - 3rd group Alarm sent as secure. + 4 - 4th group Sensor ZW3 sent as secure. + 8 - 5th group Tamper ZW3 sent as secure. + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgkf601.xml b/openzwave/fibaro/fgkf601.xml new file mode 100644 index 00000000..dffa1f9b --- /dev/null +++ b/openzwave/fibaro/fgkf601.xml @@ -0,0 +1,303 @@ + + + http://www.openzwave.com/device-database/010F:1000:1001 + images/fibaro/fgkf601.png + https://products.z-wavealliance.org/products/2064/ + 1) Place the KeyFob within the direct range of your Z-Wave controller. +2) Set the main Z-Wave controller in (security/non-security) add mode (see the controller’s manual). +3) Press any button three times. +4) Wait for the adding process to end. +5) Successful adding will be confirmed by the Z-Wave controller’s message and green LED colour. + + CEPT (Europe) + FIBARO KeyFob is a Z-Wave Plus compatible, battery-powered, compact remote control. +Six buttons allow you to control other devices through the Z-Wave network and run various scenes defined in FIBARO System. +Configure actions for one, two, three clicks and holding the button to suit all your needs. +Built-in locking system will ensure that unauthorized person will not take control of your home. + + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. There are two ways of resetting the device: +• Resetting using the menu +1) Press O and – simultaneously. +2) Press Δ or X until LED glows yellow. +3) Press + to confirm. +• Resetting on start-up +1) Remove the battery. +2) Hold O and + while inserting the battery. +Successful resetting will be confirmed by smoothly brightening and dimming of the yellow LED colour. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable + The Keyfob needs to be woken up to receive information about the new configuration from the Z-Wave controller, like parameters and associations. To wake up the device press O and + simultaneously or use 1st menu position: +1) Press O and – simultaneously. +2) Press Δ or X until LED glows white. +3) Press + to confirm. + + 1) Place the KeyFob within the direct range of your Z-Wave controller. +2) Set the main Z-Wave controller in remove mode (see the controller’s manual). +3) Press O and – simultaneously. +4) Press Δ or X until LED glows green. +5) Press + to confirm. +6) Wait for the removing process to end. +7) Successful removing will be confirmed by the Z-Wave controller’s message. + + FGKF-601 + FIBARO KeyFob + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2120/FGKF-601-EN-T-v1.0_30.11.2016.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2064/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2120/xml + + https://products.z-wavealliance.org/products/2120/ + U.S. / Canada / Mexico + FGKF-601 + + + + + + This parameter allows to activate Lock Mode and set up unlocking sequence. + Device will lock after time set in parameter 2 or after pressing and holding selected button. + 0 - Lock Mode disabled. + 9-28086 - unlocking sequence. + See "Lock Mode" on page 9 for more information. + + + + + This parameter allows to set time that must elapse from the last press of the button to lock the device and locking button. + Setting locking button will deactivate associations and scenes for pressing and holding the selected button. + This parameter is irrelevant if parameter 1 is set to 0 (Lock Mode disable). + 0 - Lock Mode disabled. + 5-1791- calculated value. + See "Lock Mode" on page 9 for more information + + + + + This parameter allows to set up sequence that activates scene with ID 7. + 0 - 1st sequence disabled. + 9-28086 - value of sequence. + See "Sequences" on page 10 for more information. + + + + + This parameter allows to set up sequence that activates scene with ID 8. + 0 - 1st sequence disabled. + 9-28086 - value of sequence. + See "Sequences" on page 10 for more information. + + + + + This parameter allows to set up sequence that activates scene with ID 9. + 0 - 1st sequence disabled. + 9-28086 - value of sequence. + See "Sequences" on page 10 for more information. + + + + + This parameter allows to set up sequence that activates scene with ID 10. + 0 - 1st sequence disabled. + 9-28086 - value of sequence. + See "Sequences" on page 10 for more information. + + + + + This parameter allows to set up sequence that activates scene with ID 11. + 0 - 1st sequence disabled. + 9-28086 - value of sequence. + See "Sequences" on page 10 for more information. + + + + + This parameter allows to set up sequence that activates scene with ID 12. + 0 - 1st sequence disabled. + 9-28086 - value of sequence. + See "Sequences" on page 10 for more information. + + + + + This parameter allows to set time that must elapse from the last press of the button to check if the sequence is valid. + Available settings: 5-30 (0.5-3s, 0.1s step) - time to lock + + + + This parameter allows to choose operating mode for single button associations. + + + + + + + This parameter allows to set value sent to devices in association group. + It will result in turning multilevel devices on with set or last level. + Value is irrelevant for simple on/off devices. + Available settings: 1-99 or 255. + + + + + This parameter allows to set value sent to devices in association group. + It will result in turning multilevel devices on with set or last level. + Value is irrelevant for simple on/off devices. + Available settings: 1-99 or 255. + + + + + This parameter allows to set value sent to devices in association group. + It will result in turning multilevel devices on with set or last level. + Value is irrelevant for simple on/off devices. + Available settings: 1-99 or 255. + + + + + This parameter allows to set value sent to devices in association group. + It will result in turning multilevel devices on with set or last level. + Value is irrelevant for simple on/off devices. + Available settings: 1-99 or 255. + + + + + This parameter allows to set value sent to devices in association group. + It will result in turning multilevel devices on with set or last level. + Value is irrelevant for simple on/off devices. + Available settings: 1-99 or 255. + + + + + This parameter allows to set value sent to devices in association group. + It will result in turning multilevel devices on with set or last level. + Value is irrelevant for simple on/off devices. + Available settings: 1-99 or 255. + + + + + This parameter allows to activate paired buttons association mode for Square and Circle buttons. + Paired buttons are dependent and association are sent only to Square groups. Circle turns devices on and increases value, Square turns them off and decreases value. + + + + + + + This parameter allows to activate paired buttons association mode for Cross and Triangle buttons. + Paired buttons are dependent and association are sent only to Cross groups. Triangle turns devices on and increases value, Cross turns them off and decreases value. + + + + + + + This parameter allows to activate paired buttons association mode for Minus and Plus buttons. + Paired buttons are dependent and association are sent only to Minus groups. Plus turns devices on and increases value, Minus turns them off and decreases value. + + + + + + + This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. + 1 - Key Pressed 1 time. + 2 - Key Pressed 2 times. + 4 - Key Pressed 3 times. + 8 - Key Held Down and Released. + Default setting: 9, 1x and hold. + + + + + This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. + 1 - Key Pressed 1 time. + 2 - Key Pressed 2 times. + 4 - Key Pressed 3 times. + 8 - Key Held Down and Released. + Default setting: 9, 1x and hold. + + + + + This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. + 1 - Key Pressed 1 time. + 2 - Key Pressed 2 times. + 4 - Key Pressed 3 times. + 8 - Key Held Down and Released. + Default setting: 9, 1x and hold. + + + + + This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. + 1 - Key Pressed 1 time. + 2 - Key Pressed 2 times. + 4 - Key Pressed 3 times. + 8 - Key Held Down and Released. + Default setting: 9, 1x and hold. + + + + + This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. + 1 - Key Pressed 1 time. + 2 - Key Pressed 2 times. + 4 - Key Pressed 3 times. + 8 - Key Held Down and Released. + Default setting: 9, 1x and hold. + + + + + This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. + 1 - Key Pressed 1 time. + 2 - Key Pressed 2 times. + 4 - Key Pressed 3 times. + 8 - Key Held Down and Released. + Default setting: 9, 1x and hold. + + + + + Parameter defines how commands are sent in specified association groups: using Security Mode or not. + Parameter is active only in Z-Wave network Security Mode. It does not apply to 1st Lifeline association group. + 1 : 2nd group sent using Security Mode. + 2 : 3rd group sent using Security Mode. + 4 : 4th group sent using Security Mode. + 8 : 5th group sent using Security Mode. + 16 : 6th group sent using Security Mode. + 32 : 7th group sent using Security Mode. + 64 : 8th group sent using Security Mode. + 128 : 9th group sent using Security Mode. + 256 : 10th group sent using Security Mode. + 512 : 11th group sent using Security Mode. + 1024 : 12th group sent using Security Mode. + 2048 : 13th group sent using Security Mode. + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgms.xml b/openzwave/fibaro/fgms.xml new file mode 100644 index 00000000..fa43926a --- /dev/null +++ b/openzwave/fibaro/fgms.xml @@ -0,0 +1,358 @@ + + + http://www.openzwave.com/device-database/010F:1001:0800 + images/fibaro/fgms.png + https://products.z-wavealliance.org/products/1048/ + FIBARO Motion Sensor + CEPT (Europe) + Motion Sensor + FGMS-001 (EU) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1048/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1076/xml + + https://products.z-wavealliance.org/products/1076/ + U.S. / Canada / Mexico + FGMS-001 + + + + + + + The lower the value, the more sensitive the PIR sensor. + Available settings: 8 - 255 + Default setting: 10 + + + + + Period of time through which the PIR sensor is "blind" (insensitive) to + motion. After this time period the PIR sensor will be again able to + detect motion. The longer the insensitivity period, the longer the + battery life. If the sensor is required to detect motion quickly, the time + period may be shortened. The time of insensitivity should be shorter + that the time period set in parameter 6. + Available settings: 0 - 15 + Formula to calculate the time: time [s] = 0.5 x (value + 1) + Default setting: 15 (8 seconds) + + + + + Sets the number of moves required for the PIR sensor to report + motion. The lower the value, the less sensitive the PIR sensor. It's + not recommended to modify this parameter settings. + Available settings: 0 - 3 + Formula to calculate the number of pulses: pulses = (value + 1) + Default setting: 1 (2 pulses) + + + + + + + + + Period of time during which the number of moves set in parameter 3 + must be detected in order for the PIR sensor to report motion. The + higher the value, the more sensitive the PIR sensor. It's not + recommended to modify this parameter setting. + Available settings: 0 - 3 + Formula to calculate the time: time [s] = 4 x (value + 1) + Default setting: 2 (12 seconds) + + + + + + + + + Motion alarm will be cancelled in the main controller and the + associated devices after the period of time set in this parameter. Any + motion detected during the cancellation delay time countdown will + result in the countdown being restarted. In case of small values, + below 10 seconds, the value of parameter 2 must be modified (PIR + sensor's "Blind Time"). + Available settings: 1 - 65535 + Default setting: 30 (30 seconds) + + + + + The parameter determines the part of day in which the PIR sensor + will be active. This parameter influences only the motion reports and + associations. Tamper, light intensity and temperature measurements + will be still active, regardless of this parameter settings. + Default setting: 0 (always active) + + + + + + + + The parameter defines the difference between night and day, in + terms of light intensity, used in parameter 8. + Available settings: 1 - 65535 + Default setting: 200 (200 lux) + + + + + The parameter determines the command frames sent in 1-st + association group, assigned to PIR sensor. + Values of BASIC ON and BASIC OFF command frames may be + modified by dedicated parameters. + Default setting: 0 (ON and OFF) + + + + + + + + The value of 255 allows to turn ON a device. In case of the Dimmer, + the value of 255 means turning ON at the last memorized state, e.g. + the Dimmer turned ON at 30% and turned OFF using the value of + 255, and then turned OFF, will be turned ON at 30%, i.e. the last + memorized state. + Available settings: 0 - 255 + Default setting: 255 + + + + + The command frame sent at the moment of motion alarm + cancellation, after the cancellation delay time, specified in parameter + 6, has passed. + The value of 0 allows to turn a device OFF while the value of 255 + allows to turn ON a device. In case of the Dimmer, the value of 255 + means turning ON at the last memorized state, e.g. the Dimmer + turned ON at 30% and turned OFF using the value of 255, and then + turned OFF, will be turned ON at 30%, i.e. the last memorized state. + Available settings: 0 - 255 + Default setting: 0 + + + + + The parameter determines the changes in forces acting on the Fibaro + Motion Sensor resulting in tamper alarm being reported - g-force + acceleration. + Available settings: 0 - 122 (0.08 - 2g; multiply by 0.016g; 0 = tamper inactive) + Default setting: 15 (0.224g) + + + + + Time period after which a tamper alarm will be cancelled. Another + tampering detected during the countdown to cancellation will not + extend the delay. + Available settings: 1 - 65535 + Default setting: 30 (seconds) + + + + + The parameter determines the behaviour of tamper and how it + reports. + Tamper: Tamper alarm is reported in Sensor Alarm command class. + Cancellation: Cancellation is reported in Sensor Alarm command class after the time period set in parameter 22 (Tamper Alarm Cancellation Delay). + Orientation: Sensor's orientation in space is reported in Fibaro Command Class after the time period set in parameter 22. + Vibration: The maximum level of vibrations recorded in the time period set + in parameter 22 is reported. Reports stop being sent when the + vibrations cease. The reports are sent in Sensor Alarm command + class. Value displayed in the "value" field (0 - 100) depends on the + vibrations force. Reports to the association groups are sent using + Sensor Alarm command class. + Default setting: 0 (Tamper) + + + + + + + + + + The parameter determines whether the tamper alarm frame will or + will not be sent in broadcast mode. Alarm frames sent in broadcast + mode may be received by all of the devices within communication + range (if they accept such frames). + Default setting: 0 + + + + + + + The parameter determines the change in light intensity level + resulting in illumination report being sent to the main controller. + Available settings: 0 - 65535 (1 - 65535 lux; 0 = reports are not + sent) + Default setting: 200 (200 lux) + + + + + Time interval between consecutive illumination reports. The reports + are sent even if there are no changes in the light intensity. + Available settings: 0 - 65535 (1 - 65535 seconds; 0 = reports are + not sent) + Default setting: 0 (no reports) + NOTE + Frequent reports will shorten the battery life. + Parameter value under 5 may result in blocking the + temperature reports. + + + + + The parameter determines the change in level of temperature + resulting in temperature report being sent to the main controller. + Available settings: 0 - 255 (0.1 - 25.5C; 0 = reports are not sent) + Default setting: 10 (1C) + + + + + The parameter determines how often the temperature will be + measured. The shorter the time, the more frequently the temperature + will be measured, but the battery life will shorten. + Available settings: 0 - 65535 (1 - 65535 seconds; 0 = temperature + will not be measured) + Default setting: 900 (900 seconds) + NOTE + Frequent reports will shorten the battery life. + Parameter value under 5 may result in blocking the + illumination reports. + + + + + The parameter determines how often the temperature reports will be + sent to the main controller. + Available settings: 0 - 65535 (1 - 65535 seconds; 0 = reports are not + sent) + Default setting: 0 + + + + + The value to be added to the actual temperature, measured by the + sensor (temperature compensation). + Available settings: 0 - 100 (0 to 100C) or 64536 - 65535 (-100 to -0.10C) + Default setting: 0 + + + + + The parameter determines the way in which LED behaves + after motion has been detected. + Values 1 and from 3 to 9 = single long blink at the moment of reporting + motion. No other motion will be indicated until alarm is cancelled. + Values from 10 to 18 = single long blink at the moment of reporting + motion and one short blink each time the motion is detected again. + Values from 19 to 26 = single long blink at the moment of reporting + motion and two short blinks each time the motion is detected again. + Default setting: 10 (flashlight) + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + The parameter determines the brightness of LED when indicating + motion. + Available settings: 0 - 100 (1 - 100%; 0 = brightness determined by + the ambient lighting - see parameters 82 and 83) + Default setting: 50 + + + + + The parameter is relevant only when the parameter 81 is set to 0. + Available settings: 0 to parameter 83 value + Default setting: 100 (100 lux) + + + + + The parameter is relevant only when the parameter 81 is set to 0. + Available settings: parameter 82 value to 65535 + Default setting: 1000 (1000 lux) + NOTE + The value of the parameter 83 must be higher than + the value of the parameter 82. + + + + + This parameter is relevant only when parameter 80 has been + properly configured. + Available settings: 0 to parameter 87 value (degrees Celsius) + Default setting: 18 (18C) + + + + + This parameter is relevant only when parameter 80 has been + properly configured. + Available settings: parameter 86 value to 255 (degrees Celsius) + Default setting: 28 (28C) + + + + + Indicating mode resembles a police car (white, red and blue). + Default setting: 1 (on) + + + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/fibaro/fgmszw5.xml b/openzwave/fibaro/fgmszw5.xml new file mode 100644 index 00000000..c3e01919 --- /dev/null +++ b/openzwave/fibaro/fgmszw5.xml @@ -0,0 +1,362 @@ + + + http://www.openzwave.com/device-database/010F:1001:0801 + images/fibaro/fgmszw5.png + https://products.z-wavealliance.org/products/2762/ + FGMS-001 + 1. Open the cover by turning it counter-clockwise. +2. Place the device within the direct range of your Z-Wave controller. +3. Set the main controller in remove mode (see the controller’s manual). +4. Quickly, three times press the B-button. +5. Wait for the removing process to end. +6. Successful removing will be confirmed by the Z-Wave controller’s message. + FIBARO Motion Sensor + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3379/FGMS-001-EN-T-v2.1.pdf + FIBARO Motion Sensor is a universal, Z-Wave Plus compatible multi-sensor. This device has a built-in motion sensor, temperature sensor and light sensor. Additionally, through vibrations detection, it may detect tampering attempt or an earthquake. FIBARO Motion Sensor is battery powered, completely wireless, and its casing allows for quick and non-invasive installation on any surface. The eye of the sensor visually indicates motion, temperature level, operating mode or may inform about Z-Wave network range. The device can be used for lighting scenes and presence monitoring systems. + 1. Open the cover by turning it counter-clockwise. +2. Place the device within the direct range of your Z-Wave controller. +3. Set the main controller in (security/non-security) add mode (see the controller’s manual). +4. Quickly, three times press the B-button. +5. Wait for the adding process to end. +6. Successful adding will be confirmed by the Z-Wave controller’s message. + 1. Open the cover by turning it counter-clockwise. +2. Press and hold the B-button. +3. Wait for visual indicator to glow yellow (2nd menu position). +4. Release the B-button. +5. Click the B-button to confirm selection. +6. After few seconds the device will be reset, which is signalled with the red, fading visual indicator colour. +Use reset procedure only if the primary controller is missing or inoperable. + CEPT (Europe) + The Motion Sensor will wake up at a defined time interval and will always try to communicate with the main controller. There is a possibility to wake up the device manually by clicking the B-button. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1146/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1514/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2762/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2763/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3336/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3379/xml + Force Association Single Channel on Lifeline - https://github.com/OpenZWave/open-zwave/issues/1830 + Updated Metadata Import from Z-Wave Allian Database - https://products.z-wavealliance.org/products/3513/xml + + https://products.z-wavealliance.org/products/2763/ + U.S. / Canada / Mexico + FGMS-001 + https://products.z-wavealliance.org/products/3336/ + FGMS-001 + CEPT (Europe) + https://products.z-wavealliance.org/products/3379/ + U.S. / Canada / Mexico + FGMS-001 + https://products.z-wavealliance.org/products/3513/ + Australia / New Zealand + FGMS-001 + + + + + + + + The lower the value, the more sensitive the PIR sensor is. + Available settings: 8 - 255 + Default setting: 15 + + + + + PIR sensor is blind (insensitive) to motion after last detection for the amount of time specified in this parameter. + Shorter time periods allow to detect motion more frequently, but the battery will be drained faster. + Available settings: 0 - 15 (0.5-8 seconds). + Formula to calculate the time: time [s] = 0.5 x (value+1)) + Default setting: 3 + + + + + This parameter determines the number of moves required for the PIR sensor to report motion. The higher the value, the less sensitive the PIR sensor is. + It is not recommended to modify this parameter settings! + Default setting: 1 (2 pulses) + + + + + + + + + Period of time during which the number of moves set in parameter 3 must be detected in order for the PIR sensor to report motion. + The higher the value, the more sensitive the PIR sensor is. + It is not recommended to modify this parameter setting! + Default setting: 2 (12 seconds) + + + + + + + + + Time period after which the motion alarm will be cancelled in the main controller and associated devices. + Any motion detected during this period resets the timer. + Available settings: 1 - 65535 + Default setting: 30 (30 seconds) + + + + + This parameter determines in which part of day the PIR sensor will be active. + This parameter influences only the motion reports and associations. + Tamper, light intensity and temperature measurements will be still active, regardless of this parameter settings. + Default setting: 0 (always active) + + + + + + + + This parameter defines the difference between night and day in terms of light intensity, used in parameter 8. + Available settings: 1 - 65535 + Default setting: 200 (200 lux) + + + + + This parameter determines the command frames sent to 2nd association group (assigned to PIR sensor). + Default setting: 0 (ON and OFF) + + + + + + + + The command frame sent at the moment of motion detection. + Further motion detections, during the cancellation time, will not result in sending the association. + Available settings: 0 - 255 + Default setting: 255 + + + + + The command frame sent at the moment of motion alarm cancellation, after cancellation delay time specified in parameter 6. + Available settings: 0 - 255 + Default setting: 0 + + + + + This parameter defines how commands are sent in specified association groups: as secure or non-secure. + Parameter is active only in Z-Wave network security mode. It does not apply to 1st group Lifeline. + Available settings 0 - 15: + 0 - none of the groups sent as secure 1 - 2nd group sent as secure. + 2 - 3rd group sent as secure. + 4 - 4th group sent as secure. + 8 - 5th group sent as secure. + + + + + This parameter determines the change in force acting on the device, that will result in reporting tamper alarm - g-force acceleration. + Available settings: 0 - 121 (0.08 - 2g; multiply by 0.016g; 0 = tamper inactive) + Default setting: 20 (0.4g) + + + + + Time period after which a tamper alarm will be cancelled in the main controller and associated devices. + Any tampering detected during this period will not extend the delay. + Available settings: 1 - 65535 + Default setting: 30 (seconds) + + + + + This parameter determines function of the tamper and sent reports. + It is an advanced feature serving much more functions than just detection of tampering. + Default setting: 0 (Tamper) + + + + + + + + This parameter allows to disable cancellation of the tamper alarm. + Default setting: 0 (Tamper). + + + + + + + The parameter determines whether the tamper alarm frame will or will not be sent in broadcast mode. + Alarm frames sent in broadcast mode can be received by all of the devices within range (if they accept such frames), but not repeated by them. + Default setting: 0 + + + + + + + The parameter determines whether the backward compatible tamper alarm frame will or will not be sent in broadcast mode. + Alarm frames sent in broadcast mode can be received by all of the devices within range (if they accept such frames), but not repeated by them. + This parameter provides backward compatibility with controllers not supporting Z-Wave+. + Default setting: 0 + + + + + + + This parameter determines the change in light intensity level resulting in luminance report being sent to the main controller. + Available settings: + 0 - reports are not sent. + 1-32767 (luminance in lux). + Default setting: 200 (200 lux). + + + + + Time interval between consecutive luminance reports. + The reports are sent even if there is no change in the light intensity. + Available settings: 0 - 32767. + 0 - periodical reports are not sent. + 1-32767 (in seconds). + + + + + This parameter determines the change in measured temperature that will result in new temperature report being sent to the main controller. + Available settings: 0 - 255 (0.1 - 25.5C; 0 = reports are not sent) + Default setting: 10 (1C) + + + + + Time interval between consecutive temperature measurements. + The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten. + Available settings: 0 - 32767 (1 - 32767 seconds; 0 = temperature is not measured) + Default setting: 900 (900 seconds). + + + + + Time interval between consecutive temperature reports. The reports are sent even if there is no change in the temperature. + Available settings: 0 - 32767 (1 - 32767 seconds; 0 = periodical reports are not sent) + Default setting: 0 + + + + + The value to be added to the actual temperature, measured by the sensor (temperature compensation). + Available settings: 0 - 100 (0 to 100C) or 64536 - 65535 (-100 to -0.10C) + Default setting: 0 + + + + + This parameter determines the way in which visual indicator behaves after motion has been detected. + Default setting: 10 (Flashlight mode) + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + This parameter determines the brightness of the visual LED indicator when indicating motion. + Available settings: 0 - brightness determined by the luminance (parameters 82 and 83). + 1-100 (1-100%) + Default setting: 50 (50 %) + + + + + Light intensity level below which brightness of visual indicator is set to 1%. + Available settings: 0 to value of parameter 83 (in lux). + Default setting: 100. + + + + + Light intensity level above which brightness of visual indicator is set to 100%. + Available settings: value of parameter 82 to 32767 (in lux) + Default setting: 1000 (1000 lux) + NOTE + The value of the parameter 83 must be higher than the value of the parameter 82. + + + + + This parameter is determines minimal temperature that will result in blue visual indicator colour. + Relevant only when parameter 80 has been properly configured. + Available settings: 0 to value of parameter 87 (in Celsius degree) + Default setting: 18 (18C) + + + + + This parameter is determines minimal temperature that will result in red visual indicator colour. + Relevant only when parameter 80 has been properly configured. + Available settings: value of parameter 86 to 255 (in Celsius degree) + Default setting: 28 (28C) + + + + + Indicating mode resembles a police car (white, red and blue). + Default setting: 1 (on) + + + + + + + + + true + + + + + + false + + + + + + + + + + diff --git a/openzwave/fibaro/fgpb101.xml b/openzwave/fibaro/fgpb101.xml new file mode 100644 index 00000000..55a10ace --- /dev/null +++ b/openzwave/fibaro/fgpb101.xml @@ -0,0 +1,161 @@ + + + http://www.openzwave.com/device-database/010F:1000:0F01 + images/fibaro/fgpb101.png + https://products.z-wavealliance.org/products/1944/ + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. In order to reset the device: +1) Click the Button exactly five times. +2) Press and hold the Button for at least 5 seconds. +Please use this procedure only when the network primary controller is missing or otherwise inoperable + FIBARO Button + 1) Place the Button within the direct range of your Z-Wave controller. +2) Set the main controller in remove mode (see the controller’s manual). +3) Click the Button at least six times. +4) Wait for the removing process to end. +5) Successful removing will be confirmed by the Z-Wave controller’s message. + + 1) Place the Button within the direct range of your Z-Wave controller. +2) Set the main controller in (security/non-security) add mode (see the controller’s manual). +3) Click the Button at least six times. +4) Wait for the adding process to end. +5) Successful adding will be confirmed by the Z-Wave controller’s message. + + FIBARO Button is a compact, battery-powered, Z-Wave Plus compatible device. It allows you to control devices through the Z-Wave network and run various scenes defined in FIBARO System. +Different actions may be triggered with one to five clicks or by holding the button down. In Panic Button mode, each press of the button results in triggering the Fibaro Alarm. +With its small design and wireless communication, the FIBARO Button can be conveniently mounted on any surface and in any position or location at home, e.g. beside the bed or under the desk. + + FGPB-101 + The Button needs to be woken up to receive information about the new configuration from the controller, like parameters and associations. +1) Click the Button 4 times to wake it up + + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2018/FGPB-101-EN-T-v1.1.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1944/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2017/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2018/xml + + https://products.z-wavealliance.org/products/2017/ + FGPB-101 + U.S. / Canada / Mexico + https://products.z-wavealliance.org/products/2018/ + Australia / New Zealand + FGPB-101 + + + + + + This parameter determines which actions result in sending scene IDs and attributes assigned to them. + 1 - Key Pressed 1 time. + 2 - Key Pressed 2 times. + 4 - Key Pressed 3 times. + 8 - Key Pressed 4 times. + 16 - Key Pressed 5 times. + 32 - Key Held Down. + 64 - Key Released. + Note: Values of parameter 1 may be combined, e.g. 1+2=3 means that scenes will be sent after pressing the button once or twice. + Default: 127 All. + + + + + This parameter defines how commands are sent in specified association groups: as secure or non-secure. + Parameter is active only in Z-Wave network security mode. It does not apply to 1st Lifeline group. + 1 - 2nd group sent as secure. + 2 - 3rd group sent as secure. + 4 - 4th group sent as secure. + Default: 3 All. + + + + This parameter defines commands sent to devices associated in 2nd association group after a single click + + + + + + + This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a single click. + + + This parameter defines commands sent to devices associated in 2nd association group after a double click + + + + + + + This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a double click. + + + This parameter defines commands sent to devices associated in 2nd association group after a triple click + + + + + + + This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a triple click. + + + This parameter defines commands sent to devices associated in 2nd association group after a single click + + + + + + + This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a single click. + + + This parameter defines commands sent to devices associated in 3rd association group after a double click + + + + + + + This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a double click. + + + This parameter defines commands sent to devices associated in 3rd association group after a triple click + + + + + + + This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a triple click. + + + This parameter defines commands sent to devices associated in 3rd association group after holding the button down. + + + + + + + + Parameter determines which actions result in sending alarm frames to 4th association group. + 1 - Key Pressed 1 time. + 2 - Key Pressed 2 times. + 4 - Key Pressed 3 times. + 8 - Key Pressed 4 times. + 16 - Key Pressed 5 times. + 32 - Key Held Down. + 64 - Key Released. + Default: 127 All. + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgr221.xml b/openzwave/fibaro/fgr221.xml new file mode 100644 index 00000000..aa62b2b7 --- /dev/null +++ b/openzwave/fibaro/fgr221.xml @@ -0,0 +1,77 @@ + + + + + + + + + + + + + + + + + + + + Binary inputs type configuration + + + + + + + Options for changing parameter 1-99, default 16 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Only valid for the 1.9 version of FGR221. The device offers the possibility of sending commands compatible with Command class scene activation. Information is sent to devices assigned to association group no. 3. Controllers such as Home Center 2 are able to interpret such commands and based on these commands they activate scenes, to which specific scene IDs have been assigned. The user may expand the functionality of the button connected to inputs S1 and S2 by distinguishing the actions of keys connected to those inputs. For example: double click would activate the scene goodnight and triple click would activate the scene morning. + + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgr223.xml b/openzwave/fibaro/fgr223.xml new file mode 100644 index 00000000..8249e965 --- /dev/null +++ b/openzwave/fibaro/fgr223.xml @@ -0,0 +1,309 @@ + + + http://www.openzwave.com/device-database/010F:1000:0303 + images/fibaro/fgr223.png + https://products.z-wavealliance.org/products/3278/ + FIBARO Roller Shutter 3 is powered with mains voltage so it is always awake. + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. +1. Switch off the mains voltage (disable the fuse). +2. Remove the device from the wall switch box. +3. Switch on the mains voltage. +4. Press and hold the B-button to enter the menu. +5. Wait for the LED indicator to glow yellow. +6. Quickly release and click the B-button again. +7. After few seconds the device will be restarted, which is signalled with the red LED indicator colour. +Please use this procedure only when the network primary controller is missing or otherwise inoperable." + + FGR-223 + Roller Shutter 3 + To add the device to the Z-Wave network manually: +1. Power the device. +2. Identify the S1 switch. +3. Set the main controller in (Security/non-Security Mode) add mode (see the controller’s manual). +4. Quickly, triple click the S1 switch. +5. If you are adding in Security S2, scan the DSK QR code or input the underlined part of the DSK (label on the bottom of the box). +6. Wait for the adding process to end. +7. Successful adding will be confirmed by the Z-Wave controller’s message. + +To add the device to the Z-Wave network using Smart Start: +1. Set the main controller in Security S2 Authenticated add mode (see the controller’s manual) +2. Scan the DSK QR code or input the underlined part of the DSK +3. (label on the bottom of the box). +4. Power the device (turn on the mains voltage). +5. LED will start blinking yellow, wait for the adding process to end. +6. Successful adding will be confirmed by the Z-Wave controller’s message. + + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3278/FGR-223-EN-T-v1.3.pdf + CEPT (Europe) + To remove the device from the Z-Wave network: +1. Make sure the device is powered. +2. Identify the S1 switch. +3. Set the main controller in remove mode (see the controller’s manual). +4. Quickly, triple click the S1 switch. +5. Wait for the removing process to end. +6. Successful removing will be confirmed by the Z-Wave controller’s message. + + FIBARO Roller Shutter 3 is a device designed to control roller blinds, awnings, venetian blinds, gates and other single phase, AC powered devices. +Roller Shutter 3 allows precise positioning of roller blinds or venetian blind lamellas. The device is equipped with power and energy monitoring. It allows to control connected devices either via the Z-Wave network or via a switch connected directly to it. +Main features of FIBARO Roller Shutter 3: +- Compatible with any Z-Wave or Z-Wave Plus Controller, +- Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption, +- To be installed with roller blind motors with electronic or mechanical limit switches, +- Advanced microprocessor control, +- Active power and energy metering functionality, +- Works with various types of switches – momentary, toggle and dedicated roller blind switches, +- To be installed in wall switch boxes, +- Works as a Z-Wave signal repeater. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3183/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3278/xml + + + + + + + This parameter defines as what type the device should treat the switch connected to the S1 and S2 terminals. + This parameter is not relevant in gate operating modes (parameter 151 set to 3 or 4). + In this case switch always works as a momentary and has to be connected to S1 terminal. + + + + + + + + This parameter allows reversing the operation of switches connected to S1 and S2 without changing the wiring. + Default: S1 -> 1st channel, S2 -> 2nd channel. + Reversed: S1 -> 2nd channel, S2 -> 1st channel. + + + + + + + This parameter allows reversing the operation of Q1 and Q2 without changing the wiring (in case of invalid motor connection) to ensure proper operation. + - Default: Q1 -> 1st channel, Q2 -> 2nd channel. + - Reversed: Q1 -> 2nd channel, Q2 -> 1st channel. + + + + + + + This parameter determines to which alarm frames and how the device should react. + The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. + 1B [MSB] - notification Type. + 2B - notification Status. + 3B - Event/State Parameters. + 4B [lSB] action: + 0 - no action, + 1 - open blinds, + 2 - close blinds. + Default setting: [0x00, 0x00, 0x00, 0x00] + + + + + This parameter determines to which alarm frames and how the device should react. + The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. + 1B [MSB] - notification Type. + 2B - notification Status. + 3B - Event/State Parameters. + 4B [lSB] action: + 0 - no action, + 1 - open blinds, + 2 - close blinds. + Default setting: [0x05, 0xFF, 0x00, 0x00] (Water Alarm, any notification, no action) + + + + + This parameter determines to which alarm frames and how the device should react. + The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. + 1B [MSB] - notification Type. + 2B - notification Status. + 3B - Event/State Parameters. + 4B [lSB] action: + 0 - no action, + 1 - open blinds, + 2 - close blinds. + Default setting: [0x01, 0xFF, 0x00, 0x00] (Smoke Alarm, any notification, no action) + + + + + This parameter determines to which alarm frames and how the device should react. + The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. + 1B [MSB] - notification Type. + 2B - notification Status. + 3B - Event/State Parameters. + 4B [lSB] action: + 0 - no action, + 1 - open blinds, + 2 - close blinds. + Default setting: [0x02, 0xFF, 0x00, 0x00] (CO Alarm, any notification, no action) + + + + + This parameter determines to which alarm frames and how the device should react. + The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. + 1B [MSB] - notification Type. + 2B - notification Status. + 3B - Event/State Parameters. + 4B [lSB] action: + 0 - no action, + 1 - open blinds, + 2 - close blinds. + Default setting: [0x04, 0xFF, 0x00, 0x00] (Heat Alarm, any notification, no action) + + + + + This parameter determines which actions result in sending scene IDs assigned to them. + Sum of: + 1 - Key pressed 1 time. + 2 - Key pressed 2 times. + 4 - Key pressed 3 times. + 8 - Key hold down and key released. + Default setting: 0. + + + + + This parameter determines which actions result in sending scene IDs assigned to them. + Sum of: + 1 - Key pressed 1 time. + 2 - Key pressed 2 times. + 4 - Key pressed 3 times. + 8 - Key hold down and key released. + Default setting: 0. + + + + This parameter determines whether the power metering should include the amount of active power consumed by the device itself. + + + + + + This parameter determines the minimum change in consumed power that will result in sending new power report to the main controller. + For loads under 50W, the parameter is not relevant and reports are sent every 5W change. + Power reports are sent no often than every 30 seconds. + 0: reports are disabled. + 1-500 (1-500%): change in power. + Default setting: 15. + + + + + This parameter determines in what time intervals the periodic power reports are sent to the main controller. + Periodic reports do not depend on power change (parameter 61). + 0: periodic reports are disabled + 30-32400 (30-32400s): report interval. + Default setting: 3600 (1h). + + + + + This parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller. + 0: reports are disabled. + 1-500 (0.01 - 5 kWh): change in energy. + Default setting: 10 (0.1 kWh). + + + + + This parameter determines in what time intervals the periodic energy reports are sent to the main controller. + Periodic reports do not depend on energy change (parameter 65). + 0: periodic reports are disabled. + 30-32400 (30-32400s): report interval. + Default setting: 3600 (1h) + + + + + By setting this parameter to 2 the device enters the calibration mode. + The parameter relevant only if the device is set to work in positioning mode (parameter 151 set to 1, 2 or 4). + + + + + + + This parameter allows adjusting operation according to the connected device. + + + + + + + + + + For Venetian blinds (parameter 151 set to 2) the parameter determines time of full turn cycle of the slats. + For gates (parameter 151 set to 3 or 4) the parameter determines time after which open gate will start closing automatically (if set to 0, gate will not close). + The parameter is irrelevant for other modes. + 0-90000 (0 - 900s, every 0.01s) time of turn. + Default setting: 150 (1.5s). + + + + + For Venetian blinds (parameter 151 set to 2) the parameter determines slats positioning in various situations. + The parameter is irrelevant for other modes. + + + + + + + + For blinds (parameter 151 set to 1, 2, 5 or 6) the parameter determines the time after which the motor will be stopped after end switch contacts are closed. + For gates (parameter 151 set to 3 or 4) the parameter determines the time after which the gate will start closing automatically if S2 contacts are opened (if set to 0, gate will not close). + 0-600 (0 - 60s). + Default setting: 10 (1s). + + + + + Power threshold to be interpreted as reaching a limit switch. + 0: reaching a limit switch will not be detected + 1-255 (1-255W): report interval. + Default setting: 10. + + + + + This parameter determines the time needed for roller blinds to reach the top. + For modes with positioning value is set automatically during calibration, otherwise, it must be set manually. + 1-90000 (0.01 - 900.00s). + Default setting: 6000 (60s). + + + + + This parameter determines time needed for roller blinds to reach the bottom. + For modes with positioning value is set automatically during calibration, otherwise, it must be set manually. + 1-90000 (0.01 - 900.00s). + Default setting: 6000 (60s). + + + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgrgbw442.xml b/openzwave/fibaro/fgrgbw442.xml new file mode 100644 index 00000000..f049bd39 --- /dev/null +++ b/openzwave/fibaro/fgrgbw442.xml @@ -0,0 +1,313 @@ + + + RGBW Controller 2 + FIBARO RGBW Controller 2 is a universal, Z-Wave Plus compatible RGB/RGBW controller. +FIBARO RGBW Controller 2 uses PWM output signal, allowing it to control LED, RGB, RGBW strips, halogen lights and other resistive loads. It can also measure active power and energy consumed by the load. Controlled devices may be powered by 12 or 24V DC. +Inputs support momentary/toggle switches and 0-10V analog sensors, like temperature sensors, humidity sensors, light sensors etc. + +Main features of FIBARO RGBW Controller: +- Compatible with any certified Z-Wave or Z-Wave Plus controller. +- Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 Authenticated with PRNG-based encryption. +- Works as a Z-Wave signal repeater. +- Allows for controlling: » RGB/RGBW LED strip, +- one-color LED strips, +- halogen lights, +- other compliant resistive loads. +- Allows for connecting to inputs: +- switches/buttons, +- 0-10V analog sensors or potentiometers. +- Active power and energy metering. + http://www.openzwave.com/device-database/010F:1000:0902 + https://www.fibaro.com/en/products/rgbw-controller/ + https://manuals.fibaro.com/rgbw-2/ + images/fibaro/fgrgbw442.png + The FIBARO RGBW Controller 2 is powered with mains voltage so it is always awake. + 1. Power the device. +2. Set the main controller in (Security/non-Security Mode) add mode (see the controller’s manual). +3. Quickly, three times click the service button. +4. If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on the box). +5. LED will start blinking yellow, wait for the adding process to end. +6. Adding result will be confirmed by the Z-Wave controller’s message and the LED: + - Green - successful (non-secure, S0, S2 Unauthenticated), + - Magenta - successful (Security S2 Authenticated), + - Red - not successful. + + 1. Power the device. +2. Set the main controller into remove mode (see the controller’s manual). +3. Quickly, three times click the service button. +4. LED will start blinking yellow, wait for the removing process to end. +5. Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour. + + 1. Press and hold the service button to enter the menu. +2. Release service button when the device glows yellow. +3. Quickly click the service button to confirm. +4. After few seconds the device will be restarted, which is signalled with the red colour. + + + Initial version + + https://products.z-wavealliance.org/products/3589/ + CEPT (Europe) + FGRGBW-442 + https://products.z-wavealliance.org/products/3656/ + U.S. / Canada / Mexico + FGRGBW-442 + https://products.z-wavealliance.org/products/3655/ + Australia / New Zealand + FGRGBW-442 + https://products.z-wavealliance.org/products/3654/ + Russia + FGRGBW-442 + + + + true + + + + + + true + + + + + This parameter determines how the device will react in the event of power supply failure (e.g. power outage or taking out from the electrical outlet). After the power supply is back on, the device can be restored to previous state or remain switched off. Default 0. + + + + + This parameter allows to choose mode of 1st input (IN1). Change it depending on connected device. Default 2 (momentary switch). + + + + + + + + This parameter allows to choose mode of 2nd input (IN2). Change it depending on connected device. Default 2 (momentary switch). + + + + + + + + This parameter allows to choose mode of 3rd input (IN3). Change it depending on connected device. Default 2 (momentary switch). + + + + + + + + This parameter allows to choose mode of 4th input (IN4). Change it depending on connected device. Default 2 (momentary switch). + + + + + + + + This parameter determines to which alarm frames and how the device should react. +The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B [MSB] - notification Type. +2B - notification Status. +3B - Event/State Parameters. +4B [LSB] action: + 0x00 - no reaction + 0x0X - turn off selected channel + 0x1X - turn on selected channel + 0x2X - blink selected channel + 0x3Y - activate alarm sequence +Default setting: [0x00, 0x00, 0x00, 0x00] + + + This parameter determines to which alarm frames and how the device should react. +The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B [MSB] - notification Type. +2B - notification Status. +3B - Event/State Parameters. +4B [LSB] action: + 0x00 - no reaction + 0x0X - turn off selected channel + 0x1X - turn on selected channel + 0x2X - blink selected channel + 0x3Y - activate alarm sequence +Default setting: [0x05, 0xFF, 0x00, 0x00] (Water Alarm, any notification, no action) + + + This parameter determines to which alarm frames and how the device should react. +The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B [MSB] - notification Type. +2B - notification Status. +3B - Event/State Parameters. +4B [LSB] action: + 0x00 - no reaction + 0x0X - turn off selected channel + 0x1X - turn on selected channel + 0x2X - blink selected channel + 0x3Y - activate alarm sequence +Default setting: [0x01, 0xFF, 0x00, 0x00] (Smoke Alarm, any notification, no action) + + + This parameter determines to which alarm frames and how the device should react. +The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B [MSB] - notification Type. +2B - notification Status. +3B - Event/State Parameters. +4B [LSB] action: + 0x00 - no reaction + 0x0X - turn off selected channel + 0x1X - turn on selected channel + 0x2X - blink selected channel + 0x3Y - activate alarm sequence +Default setting: [0x02, 0xFF, 0x00, 0x00] (CO Alarm, any notification, no action) + + + This parameter determines to which alarm frames and how the device should react. +The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B [MSB] - notification Type. +2B - notification Status. +3B - Event/State Parameters. +4B [LSB] action: + 0x00 - no reaction + 0x0X - turn off selected channel + 0x1X - turn on selected channel + 0x2X - blink selected channel + 0x3Y - activate alarm sequence +Default setting: [0x04, 0xFF, 0x00, 0x00] (Heat Alarm, any notification, no action) + + + This parameter determines the duration of alarm signaling (flashing mode and/or alarm sequence). Available values: +0 - infinite signalization +1-32400 (1s-9h, 1s step) +Default 600 (10min). + + + This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 20 is set to 2, 3 or 4. Actions can be summed up, e.g. 1+2+4+8=15 and entered as a value for the parameter. Available values: +1 - Key pressed 1 time +2 - Key pressed 2 times +4 - Key pressed 3 times +8 - Key hold down and key released +Default 15. + + + This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 20 is set to 2, 3 or 4. Actions can be summed up, e.g. 1+2+4+8=15 and entered as a value for the parameter. Available values: +1 - Key pressed 1 time +2 - Key pressed 2 times +4 - Key pressed 3 times +8 - Key hold down and key released +Default 15. + + + This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 20 is set to 2, 3 or 4. Actions can be summed up, e.g. 1+2+4+8=15 and entered as a value for the parameter. Available values: +1 - Key pressed 1 time +2 - Key pressed 2 times +4 - Key pressed 3 times +8 - Key hold down and key released +Default 15. + + + This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 20 is set to 2, 3 or 4. Actions can be summed up, e.g. 1+2+4+8=15 and entered as a value for the parameter. Available values: +1 - Key pressed 1 time +2 - Key pressed 2 times +4 - Key pressed 3 times +8 - Key hold down and key released +Default 15. + + + This parameter determines in what time intervals the periodic power reports are sent to the main controller. Periodic reports do not depend of power change (parameter 61). Available values: +0 - periodic reports are disabled +30-32400 (30-32400s) - report interval +Default 3600 (1h). + + + This parameter defines minimal change (from the last reported) of analog input voltage that results in sending new report and change in the output value. Parameter is relevant only for analog inputs (parameter 20, 21, 22 or 23 set to 0 or 1). Available values: +0 - reporting on change disabled +1-100 (0.1-10V, 0.1V step) +Default 5 (0.5V). + + + This parameter defines reporting period of analog inputs value. Periodical reports are independent from changes in value (parameter 63). Parameter is relevant only for analog inputs (parameter 20, 21, 22 or 23 set to 0 or 1). Available values: +0 - periodical reports disabled +30-32400 (30-32400s, 1s step) +Default 0 (periodical reports disabled). + + + This parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller. Energy reports are sent no often than every 30 seconds. Available values: +0 - reports are disabled +1-500 (0.01 - 5 kWh) - change in energy +Default 10 (0.1 kWh). + + + This parameter determines in what time intervals the periodic energy reports are sent to the main controller. Periodic reports do not depend of energy change (parameter 65) Available values: +0 - periodic reports are disabled +30-32400 (30-32400s) - report interval +Default 3600 (1h). + + + + This parameter determines how connected switches control LED strips. Default 0. + + + + + This parameter determines time of smooth transition between 0% and 100% when controlling with connected switches. Available values: +0 - instantly +1-127 (1s-127s, 1s step) +128-254 (1min-127min, 1min step) +Default 3. + + + This parameter determines time of smooth transition between initial and target state when controlling via Z-Wave network. Available values: +0 - instantly +1-127 (1s-127s, 1s step) +128-254 (1min-127min, 1min step) +Default 3. + + + This parameter defines value sent to devices in association groups. The parameters consist of 4 bytes, each byte reserved for separate channel, from least significant (IN1) to most significant (IN4). Applicable for Basic Set and Switch Multilevel Set commands. Available values: +For every byte: 0-99, 255. +Default 4294967295 (0xFF FF FF FF - 255 for all channels). + + + This parameter defines value sent to devices in association groups. The parameters consist of 4 bytes, each byte reserved for separate channel, from least significant (IN1) to most significant (IN4). Applicable for Basic Set and Switch Multilevel Set commands. Available values: +For every byte: 0-99, 255. +Default 0 (0x00 00 00 00 - 0 for all channels). + + + This parameter defines value sent to devices in association groups. The parameters consist of 4 bytes, each byte reserved for separate channel, from least significant (IN1) to most significant (IN4). Applicable for Basic Set and Switch Multilevel Set commands. Available values: +For every byte: 0-99, 255. +Default 0 (0x63 63 63 63 - 99 for all channels). + + + Setting this parameter will start programmed sequence with selected number. User can define own sequences via controller. Default 0. + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgrgbwm441.xml b/openzwave/fibaro/fgrgbwm441.xml new file mode 100644 index 00000000..dd3e5b1a --- /dev/null +++ b/openzwave/fibaro/fgrgbwm441.xml @@ -0,0 +1,165 @@ + + + http://www.openzwave.com/device-database/010F:1000:0900 + images/fibaro/fgrgbwm441.png + https://products.z-wavealliance.org/products/1054/ + FGRGBWM-441 + FIBARO RGBW Dimmer + CEPT (Europe) + RGBW Controller + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1054/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1072/xml + + https://products.z-wavealliance.org/products/1072/ + U.S. / Canada / Mexico + FGRGBWM-441 + + + + + true + + + + + + + + + + true + + + + + + + + + + + + + + + + + + + + + + + + + + + Enable/Disable ALL ON/OFF + + + + + + + Choose which command classes are sent to associated devices. + + + + + + + + Choose the behaviour of transitions between different levels. + + + + + Size of the step for each change in level during the transition. + + + Time between each step in a transition between levels. Setting this to zero means an instantaneous change. + + + 0 - immediate change; 1->63: 20ms->126ms (value*20ms); 65->127: 1s->63s (value-64)*1s; 129->191: 10s->630s (value-128)*10s; 193->255: 1min->63min (value-192)*1min. Default setting: 67 (3s) + + + Maximum brightness level for the dimmer + + + Minimum brightness level for the dimmer + + + This is too complex to describe here, since this value is built up from 4-bits for each of the 4 channels. Refer to the table in the product manual. Default value is 4369 (1111 in hex). + + + Option double click (lighting set at 100%). 0 - Double click disabled, 1 - Double click enabled. Default setting 1 + + + + + Saving state before power failure + + + + + Alarm of any type (general alarm, water flooding alarm, smoke alarm: CO, CO2, temperature alarm). Default setting 0 (Inactive) + + + + + + + Program number selected from the 10 available. + + + In ALARM PROGRAM mode (see parameter 30), this defines the time in seconds the program lasts (1s->65534s) + + + Specify which command class is used to report output status changes + + + + + + Parameter defines a value by which input voltage must change in order to be reported to the main controller. New value is calculated based on last reported value: Default setting: 5 (0.5V). Range: 1->100 - (0.1V->10V). + + + Sent if last reported value differs from the current value. Reports will also be sent in case of polling. Default setting: 30 (30s). Range: 1->65534 (1s->65534s) - interval between reports. Zero means reports are only sent in the case of polling, or at turning OFF the device + + + Interval between energy consumption reports (in kWh). New reported energy consumption value is calculated based on last reported value. 1->254 (0.01kWh->2.54kWh). Zero means changes in consumed energy will not be reported, except in case of polling. + + + Set whether to remember the previous RGB mix after the brightness has fallen to zero (black) + + + + + First predefined program to use when device is set to work in RGB/RGBW mode (parameter 14) + + + Behaviour when an input is triple-clicked + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgrm222.xml b/openzwave/fibaro/fgrm222.xml new file mode 100644 index 00000000..29d98a3b --- /dev/null +++ b/openzwave/fibaro/fgrm222.xml @@ -0,0 +1,177 @@ + + + + + + + Once the Local Protection is activated, the module stops responding to S1 and S2 push buttons. SCENE ID and association commands will not be sent as well. The only exception is the B-button. Menu and Z-Wave network inclusion, after the B-button or S1 push button triple click, are still active. + + + + + + + Once the RF Protection is activated, the module stops responding to command frames setting the blind position. It's still possible however to configure the device (advanced configuration parameters, protection modes) and checking it's current state through polling (position, power, energy). + + + + + + + + Parameters value shoud be set to 1 if the module operates in Venetian Blind mode. + Default setting: 0 + + + + + + Default setting: 1 + + + + + + + + + In Venetian Blind mode (parameter 10 set to 2) the parameter determines time of full turn of the lamellas. + In Gate Mode (parameter 10 set to 3 or 4) the parameter defines the COUNTDOWN time, i.e. the time period after which an open gate starts closing. + In any other operating mode the parameter value is irrelevant. Value of 0 means the gate will not close automatically + Available settings: 0-65535 (0 - 655,35s) + Default setting: 150 (1,5 s) + + + + In Venetian Blind Mode (parameter 10 set to 2) the parameter influences lamellas positioning in various situations. In any other operating mode the parameter value is irrelevant. + Default setting: 1 + + + + + + + The parameter settings are relevant for Roller Blind Mode and Venetian Blind Mode (parameter 10 set to 0, 1, 2). + + + + + + + In Roller Blind Mode or Venetian Blind mode (parameter 10 set to 0, 1, 2) the parameter determines when the Roller Shutter relays are turned off after reaching a limit switch. + In Gate Mode (parameter 10 set to 3 or 4) the parameter determines a time period after which a gate will start closing after a S2 contact has been disconnected. In this mode, time to turn off the Roller Shutter relays after reaching a limit switch is set to 3 seconds and cannot be modified. + Value of 0 means the gate will note close automatically. + Available settings: 0 - 255 (0,1-25,5s). + Default setting: 10 (1s). + + + + Power threshold to be interpreted as reaching a limit switch. + Available settings: 0 - 255 (1-255 W) + The value of 0 means reaching a limit switch will not be detected + Default setting: 10 (10W). + + + + Time period for the motor to continue operation. + Available settings: 0 - 65535 (0 - 65535s) + The value of 0 means the function is disabled. + Default setting: 240 (240s. - 4 minutes) + + + + By modifying the parameters setting from 0 to 1 a Roller Shutter enters the calibration mode. The parameter relevant only if a Roller Shutter is set to work in positioning mode (parameter 10 set to 1, 2 or 4). + + + + + + + Default setting: 2-Close blind + + + + + + + Default setting: 0-No reaction + + + + + + + Default setting: 1-Open blind + + + + + + + Default setting: 1-Open blind + + + + + + + In Venetian Blind Mode (parameter 10 set to 2), the parameter determines how the lamellas will react upon alarm detection. In any other modes, the parameter value is not relevant. + Default setting: 1 Set lamellas to their extreme position + + + + + + + Power level change that will result in new power value report being sent. The parameter defines a change that needs to occur in order to trigger the report. The value is a percentage of the previous report. + Power report threshold available settings: 1-100 (1-100%). + Value of 0 means the reports are turned off. + Default setting: 10 (10%). + + + + The parameter defines a time period between consecutive reports. + Available settings: 1-65534 (1-65534 seconds) + Value of 0 means the reports are turned off. + Default setting: 3600 (3600 seconds / 60 minutes). + + + + Energy level change which will result in new energy value report being sent. The parameter defines a change that needs to occur in order to trigger the report. + Energy threshold available settings: 1-254 (0,01 - 2,54kWh). + Value of 0 means the reports are turned off. + Default setting 10 (0,1kWh). + + + + A Roller Shutter may include power and energy used by itself in reports sent to the main controller + Default setting: 0-Self-measurement inactive + + + + + + + Parameter determines whether scenes or associations are activated by the switch keys. + Default setting: 0-Associations activation + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgs211.xml b/openzwave/fibaro/fgs211.xml new file mode 100644 index 00000000..f582ea44 --- /dev/null +++ b/openzwave/fibaro/fgs211.xml @@ -0,0 +1,104 @@ + + + + + + + + Enable/Disable ALL ON/OFF + + + + + + + + Auto off relay after specified time, with the possibility of manual override - immediate Off after button push. + Default value: 0 Manual override disabled + + + + + + Automatic turning off relay 1 after set time, (0-255) in 10ms increments for FW1.0 to FW2.0, (0-65535) in 100 ms increment for FW2.1+ + + + + Activate/Deactivate association sending for group 1 - Also see param #15 + + + + + + + In case of bi-stable switches, define their behaviour (toggle or follow) + + + + + + Binary inputs type configuration + + + + + + Enable/Disable operation of dimmer or roller shutter devices associated to group 1. + Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation + + + + + + Saving state before power failure + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgs212.xml b/openzwave/fibaro/fgs212.xml new file mode 100644 index 00000000..caf74ebf --- /dev/null +++ b/openzwave/fibaro/fgs212.xml @@ -0,0 +1,108 @@ + + + + + + + + Enable/Disable ALL ON/OFF + + + + + + + + Auto off relay after specified time, with the possibility of manual override - immediate Off after button push. + Default value: 0 Manual override disabled + + + + + + + Time period for auto off, in milliseconds (0,1 s to 6553,5 s) + 0 - Auto off disabled + Default value: 0 + + + + + Activate/Deactivate association sending for group 1 - Also see param #15 + + + + + + + In case of bi-stable switches, define their behaviour (toggle or follow) + + + + + + Binary inputs type configuration + + + + + + Enable/Disable operation of dimmer or roller shutter devices associated to group 1. + Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation + + + + + + Saving state before power failure + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgs213.xml b/openzwave/fibaro/fgs213.xml new file mode 100644 index 00000000..5fa0ef96 --- /dev/null +++ b/openzwave/fibaro/fgs213.xml @@ -0,0 +1,307 @@ + + + http://www.openzwave.com/device-database/010F:1000:0403 + images/fibaro/fgs213.png + https://products.z-wavealliance.org/products/2730/ + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. In order to reset the device: + +1) Switch off the mains voltage (disable the fuse). +2) Remove the Switch 2 from the wall switch box. +3) Switch on the mains voltage. +4) Press and hold the B-button to enter the menu. +5) Wait for the visual LED indicator to glow yellow. +6) Quickly release and click the B-button again. +7) After few seconds the device will be restarted, which is signalled with the red LED indicator colour. + +Use reset procedure only if the primary controller is missing or inoperable. + + FGS-213 + 1) Switch off the mains voltage (disable the fuse). +2) Make sure the Switch 2 is within the direct range of your Z-Wave controller. +3) Connect the device in accordance with one of the diagrams included in the manual. +4) After verifying correctness of the connection switch on the mains voltage. +5) Identify the S1 switch or the B-button (located on the device’s housing). +6) Set the main controller in (security/non-security) add mode (see the controller’s manual). +7) Quickly, three times press the S1 switch or the B-button. +8) Wait for the adding process to end. +9) Successful adding will be confirmed by the Z-Wave controller’s message. + + The FIBARO Single Switch 2 is powered with the mains voltage so it is always awake. + The remotely operated FIBARO Single Switch 2 is designed to turn electrical devices on and off and to measure their power and energy consumption. The compact size of the device makes it the world's smallest of its type and allows for the product to be installed in wall switch boxes or housings. FIBARO Single Switch 2 can be controlled either via Z-Wave network or with a wall switch through a direct connection. + CEPT (Europe) + 1) Make sure the Switch 2 is within the direct range of your Z-Wave controller. +2) Identify the S1 switch or the B-button (located on the device’s housing). +3) Set the main controller in remove mode (see the controller’s manual). +4) Quickly, three times press the S1 switch or the B-button. +5) Wait for the removing process to end. +6) Successful removing will be confirmed by the Z-Wave controller’s message + + FIBARO Single Switch 2 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2750/FGS-2x3-EN-T-v1.2.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1734/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1871/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2730/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2750/xml + + https://products.z-wavealliance.org/products/2750/ + U.S. / Canada / Mexico + FGS-213 + + + + + false + + + + + + Saving state before power failure + + + + + This parameter allows to choose operating for the 1st channel controlled by the S1 switch. + + + + + + + + + This parameter determines how the device in timed mode reacts to pushing the switch connected to the S1 terminal. + + + + + + This parameter allows to set time parameter used in timed modes. (s) + + + + This parameter allows to set time of switching to opposite state in flashing mode. + 1-32000 (0.1-3200.0s, 0.1s step) + + + + This parameter allows to choose operating for the 2st channel controlled by the S2 switch. + + + + + + + + + This parameter determines how the device in timed mode reacts to pushing the switch connected to the S2 terminal. + + + + + + This parameter allows to set time parameter used in timed modes. (s) + + + + This parameter allows to set time of switching to opposite state in flashing mode. + 1-32000 (0.1-3200.0s, 0.1s step) + + + + Inputs type configuration + + + + + + Enabled / Disabled reports on Flashing mode + + + + + + This parameter defines how commands are sent to specified association groups: as secure or non-secure. + Parameter is active only in Z-Wave network security mode. + This parameter does not apply to 1st lifeline group. + 1 - 2nd group sent as secure. + 2 - 3rd group sent as secure. + 4 - 4th group sent as secure. + 8 - 5th group sent as secure. + Default setting: 15 (all) + + + + + This parameter determines which actions result in sending scene IDs assigned to them. + 1 - Key pressed 1 time. + 2 - Key pressed 2 times. + 4 - Key pressed 3 times. + 8 - Key Hold Down and Key Released. + Default setting: 0 (none) + + + + + This parameter determines which actions result in sending scene IDs assigned to them. + 1 - Key pressed 1 time. + 2 - Key pressed 2 times. + 4 - Key pressed 3 times. + 8 - Key Hold Down and Key Released. + Default setting: 0 (none) + + + + + This parameter determines which actions are ignored when sending commands to devices associated in 2nd and 3rd association group. + All actions are active by default. + 1 - ignore turning On with 1 click of the switch. + 2 - ignore turning OFF with 1 click of the switch. + 4 - ignore holding and releasing the switch. + 8 - ignore double click of the switch. + Default setting: 0 + + + + + This parameter determines value sent with Switch On command to devices associated in 2nd and 3rd association group. + + + + + This parameter determines value sent with Switch Off command to devices associated in 2nd and 3rd association group. + + + + + This parameter determines value sent with Double Click command to devices associated in 2nd and 3rd association group. + + + + + This parameter determines which actions are ignored when sending commands to devices associated in 4th and 5th association group. + All actions are active by default. + 1 - ignore turning On with 1 click of the switch. + 2 - ignore turning OFF with 1 click of the switch. + 4 - ignore holding and releasing the switch. + 8 - ignore double click of the switch. + Default setting: 0 + + + + + This parameter determines value sent with Switch On command to devices associated in 4th and 5th association group. + + + + + This parameter determines value sent with Switch Off command to devices associated in 4th and 5th association group. + + + + + This parameter determines value sent with Double Click command to devices associated in 4th and 5th association group. + + + + This parameter determines how the device will react to General Alarm frame. + + + + + + + This parameter determines how the device will react to Flood Alarm frame. + + + + + + + This parameter determines how the device will react to CO/CO2/Smoke Alarm frame. + + + + + + + This parameter determines how the device will react to Heat alarm frame. + + + + + + + + This parameter allows to set duration of flashing alarm mode. + 1-32000 (0.1-32000s, 1s step) Default: 600 (10min) + + + + + This parameter determines the minimum change in consumed power + that will result in sending new power report to the main controller. + 1-100 (%) Default 20 (20%) + + + + + This parameter determines minimum time that has to elapse before + sending new power report to the main controller. + 1-120 (s) Default 10 (10s) + + + + + This parameter determines the minimum change in consumed energy + that will result in sending new energy report to the main controller. + 1-32000 (0.01-320 kWh) Default 100 (1kWh) + + + + + This parameter determines in what time interval the periodic + power reports are sent to the main controller. + 1-32000 (s) Default 3600 (1h) + + + + + This parameter determines in what time interval the periodic + power reports are sent to the main controller. + 1-32000 (s) Default 3600 (1h) + + + + + This parameter determines whether energy metering should include + the amount of energy consumed by the device itself. Results are + being added to energy reports for first endpoint. + + + + + + + + + true + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/fibaro/fgs221.xml b/openzwave/fibaro/fgs221.xml new file mode 100644 index 00000000..ec03e5c0 --- /dev/null +++ b/openzwave/fibaro/fgs221.xml @@ -0,0 +1,129 @@ + + + + + Enable/Disable ALL ON/OFF + + + + + + + Auto off relay after specified time, with the possibility of manual override - immediate Off after button push. + Default value: 0 Manual override disabled + + + + + Automatic turning off relay 1 after set time, (0-255) in 10ms increments for FW1.0 to FW2.0, (0-65535) in 100 ms increment for FW2.1+ + + + Automatic turning off relay 2 after set time, (0-255) in 10ms increments for FW1.0 to FW2.0, (0-65535) in 100 ms increment for FW2.1+ + + + Correct working parameter No. 6 requires settings parameter No. 15 to 1. This activates functionality double-click - Control Dimmer/Roller Shutter. Default setting: 0 + + + + + + Correct working parameter No. 6 requires settings parameter No. 15 to 1. This activates functionality double-click - Control Dimmer/Roller Shutter. Default setting: 0 + + + + + + In case of bi-stable switches, define their behaviour (toggle or follow). Default setting: 0 + + + + + Binary inputs type configuration. Default setting: 1 + + + + + Enable/Disable operation of dimmer or roller shutter devices associated to group 1. + Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation (only mono-stable input (button)). Default setting: 0 + + + + + Saving state before power failure. Default setting: 1 + + + + + Default setting: 3 + + + + + + + Default setting: 2 + + + + + + + Default setting: 3 + + + + + + + Default setting: 1 + + + + + + + Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame. Default setting: 600 + + + Default setting: 3 + + + + + + + Default setting: 2 + + + + + + + Default setting: 3 + + + + + + + Default setting: 1 + + + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/fibaro/fgs222.xml b/openzwave/fibaro/fgs222.xml new file mode 100644 index 00000000..0b9e1ed1 --- /dev/null +++ b/openzwave/fibaro/fgs222.xml @@ -0,0 +1,139 @@ + + + + + Enable/Disable ALL ON/OFF + + + + + + + Auto off relay after specified time, with the possibility of manual override - immediate Off after button push. + Default value: 0 Manual override disabled + + + + + + Time period for auto off, in milliseconds (0,1 s to 6553,5 s) + 0 - Auto off disabled + Default value: 0 + + + + + Time period for auto off, in milliseconds (0,1 s to 6553,5 s) + 0 - Auto off disabled + Default value: 0 + + + + Activate/Deactivate association sending for group 1 - Also see param #16 + + + + + + Key no.2 is not represented by any physical device except of devices on association list. + This functionality prevents of lack of reaction on pressing key no.2 through polling devices + from association list one by one and checking their actual statuses. + + + + + + In case of bi-stable switches, define their behaviour (toggle or follow) + + + + + Binary inputs type configuration + + + + + Enable/Disable operation of dimmer or roller shutter devices associated to group 1. + Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation + + + + + Saving state before power failure + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/fibaro/fgs223.xml b/openzwave/fibaro/fgs223.xml new file mode 100644 index 00000000..f7e13707 --- /dev/null +++ b/openzwave/fibaro/fgs223.xml @@ -0,0 +1,333 @@ + + + http://www.openzwave.com/device-database/010F:1000:0203 + images/fibaro/fgs223.png + https://products.z-wavealliance.org/products/2731/ + 1) Make sure the Switch 2 is within the direct range of your Z-Wave controller. +2) Identify the S1 switch or the B-button (located on the device’s housing). +3) Set the main controller in remove mode (see the controller’s manual). +4) Quickly, three times press the S1 switch or the B-button. +5) Wait for the removing process to end. +6) Successful removing will be confirmed by the Z-Wave controller’s message. + + The remotely operated FIBARO Double Switch 2 is designed to turn two electrical devices on and off and to measure their power and energy consumption. The compact size of the device makes it the world's smallest of its type and allows for the product to be installed in wall switch boxes or housings. FIBARO Double Switch 2 can be controlled either via Z-Wave network or with a wall switch through a direct connection. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2753/FGS-2x3-EN-T-v1.2.pdf + 1) Switch off the mains voltage (disable the fuse). +2) Make sure the Switch 2 is within the direct range of your Z-Wave controller. +3) Connect the device in accordance with one of the diagrams included in the manual. +4) After verifying correctness of the connection switch on the mains voltage. +5) Identify the S1 switch or the B-button (located on the device’s housing). +6) Set the main controller in (security/non-security) add mode (see the controller’s manual). +7) Quickly, three times press the S1 switch or the B-button. +8) Wait for the adding process to end. +9) Successful adding will be confirmed by the Z-Wave controller’s message. + + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. In order to reset the device: + +1) Switch off the mains voltage (disable the fuse). +2) Remove the Switch 2 from the wall switch box. +3) Switch on the mains voltage. +4) Press and hold the B-button to enter the menu. +5) Wait for the visual LED indicator to glow yellow. +6) Quickly release and click the B-button again. +7) After few seconds the device will be restarted, which is signalled with the red LED indicator colour. + +Use reset procedure only if the primary controller is missing or inoperable. + + FGS-223 + FIBARO Double Switch 2 + CEPT (Europe) + The FIBARO Double Switch 2 is powered with the mains voltage so it is always awake. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1742/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1874/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1875/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2731/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2751/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2753/xml + + https://products.z-wavealliance.org/products/2751/ + FGS-223 + U.S. / Canada / Mexico + https://products.z-wavealliance.org/products/2753/ + FGS-223 + Australia / New Zealand + + + + + false + + + + + + Saving state before power failure + + + + + This parameter allows to choose operating for the 1st channel controlled by the S1 switch. + + + + + + + + + This parameter determines how the device in timed mode reacts to pushing the switch connected to the S1 terminal. + + + + + + This parameter allows to set time parameter used in timed modes. (s) + + + + This parameter allows to set time of switching to opposite state in flashing mode. + 1-32000 (0.1-3200.0s, 0.1s step) + + + + This parameter allows to choose operating for the 2nd channel controlled by the S2 switch. + + + + + + + + + This parameter determines how the device in timed mode reacts to pushing the switch connected to the S2 terminal. + + + + + + This parameter allows to set time parameter used in timed modes. (s) + + + + This parameter allows to set time of switching to opposite state in flashing mode. + 1-32000 (0.1-3200.0s, 0.1s step) + + + + Inputs type configuration + + + + + + Enabled / Disabled reports on Flashing mode + + + + + + This parameter defines how commands are sent to specified association groups: as secure or non-secure. + Parameter is active only in Z-Wave network security mode. + This parameter does not apply to 1st lifeline group. + 1 - 2nd group sent as secure. + 2 - 3rd group sent as secure. + 4 - 4th group sent as secure. + 8 - 5th group sent as secure. + Default setting: 15 (all) + + + + + This parameter determines which actions result in sending scene IDs assigned to them. + 1 - Key pressed 1 time. + 2 - Key pressed 2 times. + 4 - Key pressed 3 times. + 8 - Key Hold Down and Key Released. + Default setting: 0 (none) + + + + + This parameter determines which actions result in sending scene IDs assigned to them. + 1 - Key pressed 1 time. + 2 - Key pressed 2 times. + 4 - Key pressed 3 times. + 8 - Key Hold Down and Key Released. + Default setting: 0 (none) + + + + + This parameter determines which actions are ignored when sending commands to devices associated in 2nd and 3rd association group. + All actions are active by default. + 1 - ignore turning On with 1 click of the switch. + 2 - ignore turning OFF with 1 click of the switch. + 4 - ignore holding and releasing the switch. + 8 - ignore double click of the switch. + Default setting: 0 + + + + + This parameter determines value sent with Switch On command to devices associated in 2nd and 3rd association group. + + + + + This parameter determines value sent with Switch Off command to devices associated in 2nd and 3rd association group. + + + + + This parameter determines value sent with Double Click command to devices associated in 2nd and 3rd association group. + + + + + This parameter determines which actions are ignored when sending commands to devices associated in 4th and 5th association group. + All actions are active by default. + 1 - ignore turning On with 1 click of the switch. + 2 - ignore turning OFF with 1 click of the switch. + 4 - ignore holding and releasing the switch. + 8 - ignore double click of the switch. + Default setting: 0 + + + + + This parameter determines value sent with Switch On command to devices associated in 4th and 5th association group. + + + + + This parameter determines value sent with Switch Off command to devices associated in 4th and 5th association group. + + + + + This parameter determines value sent with Double Click command to devices associated in 4th and 5th association group. + + + + This parameter determines how the device will react to General Alarm frame. + + + + + + + This parameter determines how the device will react to Flood Alarm frame. + + + + + + + This parameter determines how the device will react to CO/CO2/Smoke Alarm frame. + + + + + + + This parameter determines how the device will react to Heat alarm frame. + + + + + + + + This parameter allows to set duration of flashing alarm mode. + 1-32000 (0.1-32000s, 1s step) Default: 600 (10min) + + + + + This parameter determines the minimum change in consumed power + that will result in sending new power report to the main controller. + 1-100 (%) Default 20 (20%) + + + + + This parameter determines minimum time that has to elapse before + sending new power report to the main controller. + 1-120 (s) Default 10 (10s) + + + + + This parameter determines the minimum change in consumed energy + that will result in sending new energy report to the main controller. + 1-32000 (0.01-320 kWh) Default 100 (1kWh) + + + + + This parameter determines the minimum change in consumed power + that will result in sending new power report to the main controller. + 1-100 (%) Default 20 (20%) + + + + + This parameter determines minimum time that has to elapse before + sending new power report to the main controller. + 1-120 (s) Default 10 (10s) + + + + + This parameter determines the minimum change in consumed energy + that will result in sending new energy report to the main controller + 1-32000 (0.01-320 kWh) Default 100 (1kWh) + + + + + This parameter determines in what time interval the periodic + power reports are sent to the main controller. + 1-32000 (s) Default 3600 (1h) + + + + + This parameter determines in what time interval the periodic + power reports are sent to the main controller. + 1-32000 (s) Default 3600 (1h) + + + + + This parameter determines whether energy metering should include + the amount of energy consumed by the device itself. Results are + being added to energy reports for first endpoint. + + + + + + + + + true + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/fibaro/fgs224.xml b/openzwave/fibaro/fgs224.xml new file mode 100644 index 00000000..5abc330a --- /dev/null +++ b/openzwave/fibaro/fgs224.xml @@ -0,0 +1,158 @@ + + + http://www.openzwave.com/device-database/010F:1000:0204 + images/fibaro/fgs224.png + https://products.z-wavealliance.org/products/3980/ + To remove the device from the Z-Wave network: +1. Power the device. +2. Set the main controller into remove mode (see the controller’s +manual). +3. Quickly, three times click the maintenance button. +4. LED will start blinking yellow, wait for the removing process to +end. +5. Successful removing will be confirmed by the Z-Wave controller’s +message and red LED colour. + + The remotely operated FIBARO Double Smart Module is designed to turn electrical devices or circuits on and off. Double Smart Module allows to control two devices or circuits. The compact size of the device allows for the product to be installed in the housings of other devices. The devices can be controlled either via the Z-Wave™ network or with buttons connected directly to them. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3980/FGS-2x4-T-EN-1.0.pdf + To add the device to the Z-Wave network manually: +1. Power the device. +2. Set the main controller in (Security/non-Security Mode) add mode +(see the controller’s manual). +3. Quickly, three times click button connected to S1/S2 or the +maintenance button. +4. LED will start blinking yellow, wait for the adding process to end. +5. If you are adding in Security S2 Authenticated, input the underlined +part of the DSK (label on the bottom of the box). +6. Adding result will be confirmed by the Z-Wave controller’s message +and the LED: +• Green – successful (non-secure, S0, S2 non-authenticated), +• Magenta – successful (Security S2 Authenticated), +• Red – not successful. + + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. In order to reset the device: +1. Press and hold the maintenance button to enter the menu. +2. Release button when the device glows yellow. +3. Quickly click the button to confirm. +4. After few seconds the device will be restarted, which is signalled +with red LED colour. + +Use reset procedure only if the primary controller is missing or inoperable. + + FGS-224 + FIBARO Double Smart Module + CEPT (Europe) + The FIBARO Double Smart Module is powered with the mains voltage so it is always awake. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/3980/XML + + + + + + This parameter determines the state of relays power supply failure (e.g. power outage). auto OFF and flashing modes the parameter not relevant and the relay will always remain off. + + + + + + This parameter allows to choose operating for channel controlled with Q/Q1 output. timed modes (value 1, 2 or 3), time is set parameter 154 and reaction to input is set with parameter 152. + + + + + + + This parameter determines how the device when changing state of S1 input in timed for first channel. + + + + + + This parameter determines how the device when changing state of S2 input in timed for second channel. + + + + + + This parameter allows to set time parameter used in timed modes. (s) + + + This parameter allows to set time parameter used in timed modes. (s) + + + This parameter determines value sent with Switch On command to devices associated in 2nd association group. + + + This parameter determines value sent with Switch Off command to devices associated in 2nd association group. + + + This parameter determines value sent with Double Click command to devices associated in 2nd association group. + + + This parameter determines value sent with Switch On command to devices associated in 3rd association group. + + + This parameter determines value sent with Switch Off command to devices associated in 3rd association group. + + + This parameter determines value sent with Double Click command to devices associated in 3rd association group. + + + This parameter determines type of Q/Q1 output. + + + + + This parameter determines type of Q2 output. + + + + + When the lock is enabled, both outputs cannot turned on at the same time. + + + + + S1 - Inputs type configuration + + + + + + S2 - Inputs type configuration + + + + + + This parameter allows reversing operation of S1 and S2 inputs changing the wiring. Use in case of incorrect wiring. + + + + + This parameter allows reversing operation of Q1 and Q2 outputs changing the wiring. Use in case of incorrect wiring. + + + + + + + + true + + + + + + + + + + + + + true + + + diff --git a/openzwave/fibaro/fgsd002.xml b/openzwave/fibaro/fgsd002.xml new file mode 100644 index 00000000..21fbf252 --- /dev/null +++ b/openzwave/fibaro/fgsd002.xml @@ -0,0 +1,141 @@ + + + http://www.openzwave.com/device-database/010F:1002:0C02 + images/fibaro/fgsd002.png + https://products.z-wavealliance.org/products/1273/ + 1) Install the battery. Visual indicator will signal the Z-Wave network adding status (green - device added, red - device not added). +2) Make sure the device is located within direct range of the Z-Wave controller. +3) Set the main controller in add mode (see main controller’s operating manual). +4) Quickly, triple click the B-button, located on FIBARO Smoke Sensor enclosure. +5) FIBARO Smoke Sensor will be detected and added to the Z-Wave network. + + Please use this procedure only in the event that the system primary controller is missing or otherwise inoperable. +FIBARO Smoke Sensor reset procedure: +1) Make sure the device is powered. +2) Press and hold the B-button for 3 seconds. Visual indicator will glow white. +3) You will hear a short signal. +4) Release the B-button. + + FGSD-002 + The FIBARO Smoke Sensor is a universal, ultra-light, perfectly designed, optical Z-Wave smoke detector. Fire alarm is signalled by sound, visual indicator blinking and alarm reports sent to the other devices within Z-wave network. The optical sensor detects smoke at an early stage of fire, often before flames appear and temperature starts to rise significantly. Moreover, the device has a built-in temperature sensor, which is adjustable to allow detection of fire by exceeding given temperature threshold. The FIBARO Smoke Sensor is a battery powered device designed to be placed on the wall or ceiling. Visual indicator signals fire, operating mode and it is used to check if the device is within the Z-wave network using a built-in Z-Wave range tester. The Smoke Sensor is designed to operate in confined spaces, under normal conditions (lacking of smoke, dust or condensed water vapor). + +Product video: +https://www.youtube.com/watch?v=50QGfkdUtns + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2837/FGSD-002-EN-A-v1.1.pdf + The Smoke Sensor will wake up at defined time interval and will ALWAYS try to communicate with the main controller. There is a possibility to wake the device up manually by triple-clicking the B-button. + FIBARO Smoke Sensor + CEPT (Europe) + 1) Make sure there is a battery installed. +2) Set the main controller in remove mode (see main controller’s operating manual). +3) Quickly, triple click the B-button, located on FIBARO Smoke Sensor enclosure. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1273/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2837/xml + Updated Text for parameter 12 + + https://products.z-wavealliance.org/products/2837/ + FGSD-002 + CEPT (Europe) + + + + + There are 3 levels of sensitivity to smoke presence. Level 1 means the highest sensitivity. Rising the parameter value lowers the sensitivity to smoke presence. + + + + + + This parameter allows to activate excess temperature and/or enclosure opening notifications sent to the main controller. + + + + + + + This parameter allows to activate visual indications but does not apply to major alarms, such as FIRE, TROUBLE and LOW BATTERY ALARM. + + + + + + + + + + + This parameter allows to activate sound signals but does not apply to major alarms, such as FIRE, TROUBLE and LOW BATTERY ALARM. + + + + + + + + + + + This parameter defines which frames will be sent in the 2-nd Association Group (FIRE ALARM). + + + + + + BASIC ON frame is sent in case of smoke presence detection and FIRE ALARM triggering. Available settings: 0,(1 - 99) or 255. Default setting: 255 + + + BASIC OFF frame is sent in case of FIRE ALARM cancellation. Available settings: 0,(1 - 99) or 255. Default setting: 0 + + + A value other than 0 means that alarms are being sent in broadcast mode, i.e. to all devices within a Fibaro Smoke Sensor's range. + + + + + + + This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It doesn't apply to 1st Lifeline group. + Available settings: 0 - 15 + 0 - all groups sent as non-secure + 1 - 2nd group sent as secure + 2 - 3rd group sent as secure + 4 - 4th group sent as secure + 8 - 5th group sent as secure + Parameter values may be combined, e.g. 1+2=3 means that 2nd and 3rd group are sent as secure. + Default setting: 15 (all groups sent as secure) + + + Time interval between consecutive temperature reports. Report is sent when new temperature value is different from the one previously reported - according to the set hysteresis (parameter 21). Available settings: 0,1-8640 (multiply by 10 seconds) [10s-24h]. Default setting: 1 (10s) + + + The temperature report will only be sent if there is a difference in temperature value from the previous value reported, defined in this parameter (hysteresis). Available settings: 1 to 100 (in 0,1C steps). Default setting: 10 (1C) + + + Temperature value measured by the built-in temperature sensor above which the excess temperature notification is sent. Available settings: 1 to 100. Default setting: 55 (55C) + + + Time interval of signaling (visual indication/sound) excess temperature level. Available settings: 1 to 8640 (multiply by 10 seconds) [10s-24h]. Default setting: 1 (10s) + + + Time interval of signaling (visual indication/sound) lack of Z-Wave range. Available settings: 1 to 8640 (multiply by 10 seconds) [10s-24h]. Default setting: 180 (30min) + + + + + + true + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgss101.xml b/openzwave/fibaro/fgss101.xml new file mode 100644 index 00000000..e875eed6 --- /dev/null +++ b/openzwave/fibaro/fgss101.xml @@ -0,0 +1,113 @@ + + + + + + false + + + + + + false + + + + + + false + + + + + + The time between when the smoke disappears and the Fibaro Smoke Sensor stops sending the alarm signal. Available settings: 0 to 17280, 65535 (5s multiplier) [5s-24h]. 0: no delay, immediate cancellation, 65535: alarm cancellation inactive - Smoke Sensor will keep indicating smoke alarm after the smoke will have disappeared. The smoke alarm can be only ceased manually, by entering 2nd menu level (see section XIII). Default setting: 0 + + + Allows for deactivating the LED indicator and the acoustic alarm, in case of detecting an alarm of any type. This doesn't affect the communication with the Z-Wave network controller, i.e. the sensor will keep sending alarms, reports and all information to the associated devices. Modifying this parameter settings helps extending the battery life. + + + + + + + Type of alarm frame for association group 1, activated by smoke sensor. The parameter allows to specify the type of alarm frame or to force transmission of control commands (BASIC_SET) + + + + + The value of 255 allows for turning on a device. In case of Dimmer, the value of 255 means turning on the device with the last memorized state. E.g. Dimmer set to 30% and then turned off, and next turned on using the 255 command, will turn on with the last remembered status, i.e. 30%. In case of alarm frames, alarm priority is defined. Available settings: (1 - 99) or 255. Default setting: 255 + + + Time interval between consecutive temperature reports. The parameter is relevant for the battery powering mode only. Longer time interval means less frequent communication and thus a longer battery life. Report is sent when new temperatue value is different from the one previously reported. Temperature reports can be also sent as a result of polling. Available settings: 1 to 17280, 0 (multiply by 5 seconds) [5s-24h]. 0 reports inactive. Default setting: 0 (Reports inactive) + + + The temperature report will only be sent if there is a difference in temperature value from the previous value reported, defined in this parameter (hysteresis). Temparature reports can be also sent as a result of polling. Available settings: 0 to 100 (in 0,1C steps). 0 temperature change reporting inactive. Default setting: 20 (2C) + + + Transmitting the alarm or control frame in "broadcast" mode (i.e. to all devices within range), information sent in this mode is not repeated by the mesh network. NOTE: If the broadcast mode of information transmission is activated for a given channel, then transmission of information in singlecast mode to devices assigned to the association group of this channel is deactivated. + + + + + + + Parameter stores a temperature value to be added to or deducted from the current temperature measured by internal temperature sensor in order to compensate the difference between air temperature and temperature measured at the ceiling level. Available settings: -1000 -/+ 1000 (in 0,1C steps). Default setting: 0 (0C) + + + Time period between the consecutive Z-Wave network range tests. In battery powering mode, Z-Wave network range test is carried out at the wake up interval. The value of 0 turns off the Z-Wave range test, regardless of the powering mode chosen. Available settings: 0 to 144 (10min multiplier) [10min-24h]. 0 Z-Wave network range test inactive. Default setting: 1 (10min) + + + Temperature value, measured by the built-in temperature sensor, above which the temperature alarm is sent. Available settings: 0,2 - 100. 0 temperature alarm inactive. 2 - 100 (2 - 100C). Default setting: 54 (54C) + + + There are 3 levels of sensitivity to smoke presence. Level 1 means the highest sensitivity. + + + + + + This parameter allows for specifying the moment in which the Black Box starts recording data. After the specified smoke and temperature values will be exceeded, the Fibaro Smoke Sensor Black Box will record them. + + + + + + Time interval in which malfunction alarm, if detected, is repeated using visual and acoustic alarms. Available settings: 1 - 255 (100 ms multiplier) [100ms-25,5s]. Default setting: 10 (1s) + + + Time interval in which temperature alarm, if detected, is repeated using visual and acoustic alarms. Available settings: 1 - 255 (100 ms multiplier) [100ms-25,5s]. Default setting: 5 (500ms) + + + Time interval in which lack of the Z-Wave network alarm, if detected, is repeated using visual and acoustic alarms. Available settings: 1 - 17280 (5s multiplier) [5s-24h]. Default setting: 360 (30min) + + + Time interval in which low battery alarm, if detected, is repeated using visual and acoustic alarms. Available settings: 1 - 17280 (5s multiplier) [5s-24h]. Default setting: 360 (30min) + + + This parameter allows for specifying the moment in which the Black Box starts recording data. After the specified smoke and temperature values will be exceeded, the Fibaro Smoke Sensor Black Box will record them. + + + + + default setting: tamper alarm active, with cancellation option available + + + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/fibaro/fgt001.xml b/openzwave/fibaro/fgt001.xml new file mode 100644 index 00000000..63f90101 --- /dev/null +++ b/openzwave/fibaro/fgt001.xml @@ -0,0 +1,122 @@ + + + http://www.openzwave.com/device-database/010F:1000:1301 + images/fibaro/fgt001.png + https://products.z-wavealliance.org/products/3194/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3194/FGT-001-EN-T-v1.0.pdf + The Heat Controller + Please use this procedure only when the network primary controller is missing or otherwise inoperable. +Reset procedure allows to restore the device back to its factory settings, which means all information about the network and user configuration will be deleted. +To perform factory reset: +1. Use the included key to press and hold the button. +2. Release the button when you see yellow LED colour. +3. Click the button to confirm the selection. +4. After finishing resetting the device will be put in Standby Mode. Click the button to activate it again. + + FIBARO Heat Controller is a remotely controlled thermostatic head to control temperature in the room. It measures the temperature and automatically adjust the heat level. It can be mounted without tools on three types of thermostatic radiator valves. It is also possible to create schedules via app to easily manage temperature throughout the week. +Main features: +• to be installed on three types of valves: M30 x 1.5, Danfoss RTD-N and Danfoss RA-N, +• compatible with any Z-Wave or Z-Wave Plus Controller, +• supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption, +• built-in battery recharged through standard micro-USB port, +• easy installation - no tools required, +• can use dedicated temperature sensor, +• supports heating schedules, +• automatic calibration, +• anti-freeze function, +• decalc function, +• unconstrained rotation spherical knob to set desired temperature. + + To add the device to the Z-Wave network: +1. Make sure the device is within the direct range of your Z-Wave controller. +2. Set the main controller in (security/non-security) add mode. +3. Use the included key to quickly triple click the button on the thermostatic head. +4. The LED ring will start blinking white. +5. If you are adding in S2 authenticated mode, type in the device pin code (underlined part of the public key on the label). +6. Wait for the adding process to end. +7. Successful adding will be confirmed by the Z-Wave controller. + + FIBARO Heat Controller is a FLiRS device. The FLiRS device alternates between sleep mode and a partially awake mode in which it is listening beam signal. When device receives this beam, it immediately fully wakes up and then communicates with the controller or other Z-Wave device. + CEPT (Europe) + FGT-001 + To remove the device from the Z-Wave network: +1. Make sure the device is within the direct range of your Z-Wave controller. +2. Set the main controller into remove mode. +3. Use the included key to quickly triple click the button on the thermostatic head. +4. The LED ring will start blinking white. +5. Wait for the removing process to end. +6. Successful removing will be confirmed by the Z-Wave controller. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2586/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2971/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3194/xml + + + + + + + + + + + + + + + + + + + + + + 0 + true + + + + + + This parameter determines duration of Override Schedule after turning the knob while normal schedule is active (set by Schedule CC). + + + This parameter allows to enable different additional functions of the device. + 1) Enable open window detector + 2) Enable fast open window detector + 4) Increase receiver sensitivity (shortens battery life) + 8) Enable LED indications when controlling remotely + 16) Protect from setting Full ON and Full OFF mode by turning the knob manually + NOTE: Parameter values may be combined, e.g. 1+8=9 means than open window detector and LED indications when controlling remotely are enabled. + + + + This parameter allows to check status of different additional functions. + 1) Optional temperature sensor connected and operational + 2) Open window detected + NOTE: Parameter values may be combined, e.g. 1+2=3 means than optional sensor works properly and open window detection was triggered. + + + + + + + + + + + true + + + + + + + + + diff --git a/openzwave/fibaro/fgwd111.xml b/openzwave/fibaro/fgwd111.xml new file mode 100644 index 00000000..31445003 --- /dev/null +++ b/openzwave/fibaro/fgwd111.xml @@ -0,0 +1,391 @@ + + + + FGWDEU-111 Walli Dimmer + FIBARO Walli Dimmer is a smart wall dimmer designed to control light source via Z-Wave network. It measures active power and energy consumed by the controlled load. + http://www.openzwave.com/device-database/010f:1000:1C01 + https://www.fibaro.com/en/products/smart-switches-and-outlets-walli-dimmer/ + https://manuals.fibaro.com/walli-dimmer/ + images/fibaro/fgwd111.png + https://manuals.fibaro.com + FIBARO Walli Dimmer is powered using DC power supply unit so it is always awake. + To add the device to the Z-Wave network manually: +1. Power the device. +2. Set the main controller in add mode(see the controller’s manual). +3. Quickly, three times click one of the buttons. +4. LED will start blinking yellow, wait for the adding process to end. +5. Adding result will be confirmed by the Z-Wave controller’s message and the LED frame: +• Green – successful (non-secure, S0, S2 non-authenticated), +• Magenta – successful (Security S2 Authenticated), +• Red – not successful. + To remove the device from the Z-Wave network: +1. Power the device. +2. Set the main controller into remove mode (see the controller’s manual). +3. Quickly, three times click one of the buttons. +4. LED will start blinking yellow, wait for the removing process to end. +5. Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour. + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. Resetting to factory defaults does not reset energy consumption memory. +1. Quickly, three times click, then press and hold one of the buttons to enter the menu. +2. Release button when the device glows yellow. +3. Quickly click the button to confirm. +4. After few seconds the device will be restarted, which is signalled with red LED colour. + https://products.z-wavealliance.org/products/3392 + FGWDEU-111 + CEPT (Europe) + + Initial Creation of config file - https://products.z-wavealliance.org/Products/3392/XML + Change definition of params 30-34 to fix https://github.com/domoticz/domoticz/issues/3557 + + + + + + + + This parameter determines how the device will react in the event of power supply failure (e.g. power outage). The parameter is not relevant for outputs set to pulse mode (parameter 150/151 set to 2). + 0 - remains switched off after restoring power + 1 - restores remembered state after restoring power + + + + + This function allows to turn off the controlled device in case of exceeding the defined power. Controlled device can be turned back on via the button or sending a control frame. + 0 - function disabled + 10-5000 - (1.0-500.0W, step 0.1W) – power threshold + + + + + This parameter determines maximum active power. Exceeding it results in the LED frame flashing violet. Function is active only when parameter 11 is set to 8 or 9. + 100-5000 - (10.0-500.0W, step 0.1W) – power threshold + + + + + This parameter defines the LED colour when thedevice is ON. When set to 8 or 9, LED frame colour will change depending on he measured power and parameter 10. Other colours are set permanently and do not depend on power consumption. + + + + + + + + + + + + + + + This parameter defines the LED colour when the device is OFF. + + + + + + + + + + + + + This parameter allows to adjust the LED frame brightness. + 0 - LED disabled + 1-100 - (1-100% brightness) + 101 - brightness directly proportional to measured power + 102 - brightness inversely proportional asured powerto me + + + + + This parameter allows reversing the operation of the buttons. + + + + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + + This parameter defines duration of alarm sequence. When time set in this parameter elapses, alarm is cancelled, LED frame and relay restore normal operation, but do not recover state from before the alarm. + 0 - Infinite + 1-32400 - (1s-9h, 1s step) – Duration + + + + + This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent). Enabling scenes for triple click disables entering the device in learn mode by triple clicking. + 1 - Key pressed 1 time + 2 - Key pressed 2 time + 4 - Key pressed 3 time + 8 - Key hold down and key released + + + + + This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent). Enabling scenes for triple click disables entering the device in learn mode by triple clicking. + 1 - Key pressed 1 time + 2 - Key pressed 2 time + 4 - Key pressed 3 time + 8 - Key hold down and key released + + + + + This parameter determines whether the power measurements should include power consumed by the device itself. + + + + + + + This parameter defines minimal change (from the last reported) in measured power that results in sending new report. For loads under 50W the parameter is irrelevant, report are sent every 5W change. + 0 - Reporting on change disabled + 1-500 - (1-500%, 1% step) – Minimal change + + + + + This parameter defines reporting interval for measured power. Periodic reports are independent from changes in value (parameter 61). + 0 - periodic reports disabled + 30-32400 - (30s-9h, 1s step) – time interval + + + + + This parameter defines minimal change (from the last reported) in measured energy that results in sending new report. + 0 - reporting on change disabled + 1-500 - (0.01-5kWh, 0.01kWh step) – minimal change + + + + + This parameter defines reporting interval for measured energy. Periodic reports are independent from changes in value (parameter 65). + 0 - periodic reports disabled + 30-32400 - (30s-9h, 1s step) – time interval + + + + + This parameter is set automatically during the calibration process, but can be changed manually after the calibration. + 1-98 - (1-98%, 1% step) – level of brightness + + + + + This parameter is set automatically during the calibration process, but can be changed manually after the calibration. + 2-99 - (2-99%, 1% step) – level of brightness + + + + + The virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The device will set to this value after the first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources. + 1-99 - (1-98%, 1% step) – level of brightness + + + + + This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality. + 0-255 - (0-25.5s, 0.1s step) – incandescence time + + + + + This parameter defines the percentage value of dimming step during the automatic control. + 0-99 - (1-99%, 1% step) – dimming step + + + + + This parameter defines the time of performing a single dimming step set in parameter 154 during the automatic control. + 0-255 - This parameter defines the time of performing a single dimming step set in parameter 154 during the automatic control. + + + + + This parameter defines the percentage value of the dimming step during the manual control. + 1-99 - (1-99%, 1% step) – dimming step + + + + + This parameter defines the time of performing a single dimming step set in parameter 156 during the manual control. + 0-255 - (0-2.55s, 10ms step) + + + + + This parameter allows to automatically switch off the device after a specified time from switching the light source on. It may be useful when the device is installed in the stairway. + 0 - auto-off disabled + 1-32767 - (1s-9.1h, 1s step) – auto-off time + + + + + Changing value of this parameter will force the calibration process. During the calibration parameter is set to 1 or 2 and switched to 0 upon completion. + + + + + + + + This parameter determines operating mode of the device (automatic/manual settings). + + + + + + + This parameter defines percentage power variation (compared to power consumption measured during the calibration) to be interpreted as load error/burnt out bulb. + 0 - function disabled + 1-99 - (1-99%, 1% step) – power variation + + + + + This parameter defines detection delay for the burnt out bulb (parameter 161) and overload (parameter 2). + 0 - detection of a burnt out bulb disabled + 1-255 - (1-255s, 1s step) – time delay + + + + + This parameter defines value sent with Switch OFF command to devices associated in 2nd and 3rd association group. + 0-99 - value sent + 254 - send value equal to the current level + 255 - value sent + + + + + This parameter defines value sent with Switch ON command to devices associated in 2nd and 3rd association group. + 0-99 - value sent + 254 - send value equal to the current level + 255 - value sent + + + + + This parameter defines brightness level set after double-clicking any of the buttons. The same value is also sent to devices associated with 2nd and 3rd association group. + 0-99 - (0-99%, 1% step) – set level + + + + + This parameter allows to set the desired load control mode. Auto-calibration sets value of this parameter to 2 (control mode recognized during auto-calibration), but the installer may force control mode using this parameter. After changing parameter value, turn the load OFF and ON to change control mode. + + + + + + + + This parameter allows to read load control mode that was set during auto-calibration. + + + + + + + This mode is necessary while connecting non-dimmable light sources. Setting this parameter to 1 automatically ignores brightening/dimming time settings. Forced auto-calibration will set this parameter’s value to 2. + + + + + + + + This parameter allows to read if the load detected during calibration procedure is dimmable. + + + + + + + This parameter allows to set time required to warm up the filament of halogen bulb. + + + + + + + + This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc. + + + + + + + + + Error occurrences related to surge or overcurrent results in turning off the output to prevent possible malfunction. By default the device performs three attempts to turn on the load (useful in case of temporary, short failures of the power supply). + + + + + + + Correction reduces spontaneous flickering of some capacitive loads (e.g. dimmable LEDs) at certain brightness levels in 2-wire installation. + In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust the time of correction for flickering loads. + 0 - automatic correction disabled + 1-254 - (1-254s, 1s step) – duration of correction + 255 - automatic correction always enabled + + + + + This parameter defines how to calculate active power. It is useful in a case of 2-wire connection with light sources other than resistive. + + + + + + + + This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level. + 0-500 - (0-500W, 1W step) – power consumed by the load at the maximum brightness level. + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgwds221.xml b/openzwave/fibaro/fgwds221.xml new file mode 100644 index 00000000..b72f9d64 --- /dev/null +++ b/openzwave/fibaro/fgwds221.xml @@ -0,0 +1,347 @@ + + + + FGWDSEU-221 Walli Double Switch + FIBARO Walli Double Switch is a smart wall switch designed to control one or two light sources via Z-Wave network. It measures active power and energy consumed by the controlled load. + http://www.openzwave.com/device-database/010f:1000:1B01 + https://www.fibaro.com/en/products/smart-switches-and-outlets-walli-switch/ + https://manuals.fibaro.com/walli-switch/ + images/fibaro/fgwds221.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/3395/FGWDSEU-221-T-EN-0.19.pdf + FIBARO Walli Double Switch is powered using DC power supply unit so it is always awake. + To add the device to the Z-Wave network manually: +1. Power the device. +2. Set the main controller in add mode(see the controller’s manual). +3. Quickly, three times click one of the buttons. +4. LED will start blinking yellow, wait for the adding process to end. +5. Adding result will be confirmed by the Z-Wave controller’s message and the LED frame: +• Green – successful (non-secure, S0, S2 non-authenticated), +• Magenta – successful (Security S2 Authenticated), +• Red – not successful. + To remove the device from the Z-Wave network: +1. Power the device. +2. Set the main controller into remove mode (see the controller’s manual). +3. Quickly, three times click one of the buttons. +4. LED will start blinking yellow, wait for the removing process to end. +5. Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour. + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. Resetting to factory defaults does not reset energy consumption memory. +1. Quickly, three times click, then press and hold one of the buttons to enter the menu. +2. Release button when the device glows yellow. +3. Quickly click the button to confirm. +4. After few seconds the device will be restarted, which is signalled with red LED colour. + https://products.z-wavealliance.org/products/3395 + FGWDSEU-221 + CEPT (Europe) + + Initial Creation of config file - https://products.z-wavealliance.org/Products/3395/XML + Change definition of params 30-34 to fix https://github.com/domoticz/domoticz/issues/3557 + Add Product Picture + + + + + + + + This parameter determines how the device will react in the event of power supply failure (e.g. power outage). The parameter is not relevant for outputs set to pulse mode (parameter 150/151 set to 2). + 0 - remains switched off after restoring power + 1 - restores remembered state after restoring power + + + + + This function allows to turn off the controlled device in case of exceeding the defined power. Controlled device can be turned back on via button or sending a control frame. + 0 - Function disabled + 10-36200 - (1.0-3620.0W, step 0.1W) – Power threshold + + + + + This function allows to turn off the controlled device in case of exceeding the defined power. Controlled device can be turned back on via button or sending a control frame. + 0 - Function disabled + 10-36200 - (1.0-3620.0W, step 0.1W) – Power threshold + + + + + This parameter determines maximum active power. Exceeding it results in the LED frame flashing violet. Function is active only when parameter 11 is set to 8 or 9. + (50.0-3000.0W, step 0.1W) – power threshold + + + + + This parameter defines the LED colour when thedevice is ON. When set to 8 or 9, LED frame colour will change depending on he measured power and parameter 10. Other colours are set permanently and do not depend on power consumption. + + + + + + + + + + + + + + + This parameter defines the LED colour when thedevice is ON. When set to 8 or 9, LED frame colour will change depending on he measured power and parameter 10. Other colours are set permanently and do not depend on power consumption. + + + + + + + + + + + + + This parameter allows to adjust the LED frame brightness. + 0 - LED disabled + 1-100 - (1-100% brightness) + 101 - brightness directly proportional to measured power + 102 - brightness inversely proportional asured powerto me + + + + + This parameter defines how device buttons should control the channels. + + + + + + + + This parameter allows reversing the operation of the buttons. + + + + + + This parameter allows reversing the operation of Q1 and Q2 without changing the wiring (e.g. in case of invalid connection). Changing orientation turns both outputs off. + + + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + + This parameter defines duration of alarm sequence. When time set in this parameter elapses, alarm is cancelled, LED frame and relay restore normal operation, but do not recover state from before the alarm. + 0 - Infinite + 1-32400 - (1s-9h, 1s step) – Duration + + + + + This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent). Enabling scenes for triple click disables entering the device in learn mode by triple clicking. + 1 - Key pressed 1 time + 2 - Key pressed 2 time + 4 - Key pressed 3 time + 8 - Key hold down and key released + + + + + This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent). Enabling scenes for triple click disables entering the device in learn mode by triple clicking. + 1 - Key pressed 1 time + 2 - Key pressed 2 time + 4 - Key pressed 3 time + 8 - Key hold down and key released + + + + + This parameter determines whether the power measurements should include power consumed by the device itself. + + + + + + + This parameter defines minimal change (from the last reported) in measured power that results in sending new report. For loads under 50W the parameter is irrelevant, report are sent every 5W change. + 0 - Reporting on change disabled + 1-500 - (1-500%, 1% step) – Minimal change + + + + + This parameter defines reporting interval for measured power. Periodic reports are independent from changes in value (parameter 61). + 0 - periodic reports disabled + 30-32400 - (30s-9h, 1s step) – time interval + + + + + This parameter defines minimal change (from the last reported) in measured power that results in sending new report. For loads under 50W the parameter is irrelevant, report are sent every 5W change. + 0 - Reporting on change disabled + 1-500 - (1-500%, 1% step) – Minimal change + + + + + This parameter defines reporting interval for measured power. Periodic reports are independent from changes in value (parameter 63). + 0 - periodic reports disabled + 30-32400 - (30s-9h, 1s step) – time interval + + + + + This parameter defines minimal change (from the last reported) in measured energy that results in sending new report. + 0 - reporting on change disabled + 1-500 - (0.01-5kWh, 0.01kWh step) – minimal change + + + + + This parameter defines reporting interval for measured energy. Periodic reports are independent from changes in value (parameter 66). + 0 - periodic reports disabled + 30-32400 - (30s-9h, 1s step) – time interval + + + + + This parameter defines minimal change (from the last reported) in measured energy that results in sending new report. + 0 - reporting on change disabled + 1-500 - (0.01-5kWh, 0.01kWh step) – minimal change + + + + + This parameter defines reporting interval for measured energy. Periodic reports are independent from changes in value (parameter 67). + 0 - periodic reports disabled + 30-32400 - (30s-9h, 1s step) – time interval + + + + + This parameter allows to choose operating for the 1st channel. + + + + + + + + This parameter allows to choose operating for the 2nd channel. + + + + + + + + This parameter determines how the device in timed mode reacts to pushing the button for 1st channel. The parameter is relevant only for button toggles modes (parameter 20 set to 1 or 3). + + + + + + + + This parameter determines how the device in timed mode reacts to pushing the button for 2nd channel. The parameter is relevant only for button toggles modes (parameter 20 set to 1 or 3). + + + + + + + + This parameter allows to set time parameter used in timed modes for 1st channel (parameter 150). Delay time for switching off or duration of the pulse. + 0 - 0.1 second + 1-32000 - 1-32000s, 1s step – time parameter + + + + + This parameter allows to set time parameter used in timed modes for 2nd channel (parameter 151). Delay time for switching off or duration of the pulse. + 0 - 0.1 second + 1-32000 - 1-32000s, 1s step – time parameter + + + + + This parameter defines value sent with Switch ON command to devices associated in 2nd and 3rd association group for manual changes of Endpoint 1 state. + 0-99 - 2nd association group + 255 - 3rd association group + + + + + This parameter defines value sent with Switch OFF command to devices associated in 2nd and 3rd association group for manual changes of Endpoint 1 state. + 0-99 - 2nd association group + 255 - 3rd association group + + + + + This parameter defines value sent with Double Click command to devices associated in 2nd and 3rd association group for manual changes of Endpoint 1 state. + 0-99 - 2nd association group + 255 - 3rd association group + + + + + This parameter defines value sent with Switch ON command to devices associated in 4th and 5th association group for manual changes of Endpoint 2 state. + 0-99 - 4th association group + 255 - 5th association group + + + + + This parameter defines value sent with Switch OFF command to devices associated in 4th and 5th association group for manual changes of Endpoint 2 state. + 0-99 - 4th association group + 255 - 5th association group + + + + + This parameter defines value sent with Double Click command to devices associated in 4th and 5th association group for manual changes of Endpoint 2 state. + 0-99 - 4th association group + 255 - 5th association group + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgwoe.xml b/openzwave/fibaro/fgwoe.xml new file mode 100644 index 00000000..cd0764ab --- /dev/null +++ b/openzwave/fibaro/fgwoe.xml @@ -0,0 +1,491 @@ + + + + FIBARO Walli Outlet + http://www.openzwave.com/device-database/010F:1000:1f01 + images/fibaro/fgwoe.png + https://manuals.fibaro.com/content/manuals/en/FGWOEF-011/FGWOEF-011-T-EN-v1.0.pdf + https://products.z-wavealliance.org/products/3220 + CEPT (Europe) + FGWOE/F-11 + FIBARO Walli Outlet is a smart electrical outlet designed to control electrical devices via Z-Wave network. +It measures active power and energy consumed by the controlled load. +You can install it with provided cover plate and socket cover or other compatible. + +Main features of FIBARO Walli Outlet: +- Can turn ON/OFF plugged device remotely. +- Available in two versions for plug types: + o Type E, + o Type F. +- Can be used with provided cover plate or one of the following: + o GIRA - System 55 (Standard 55, E2, Event, Event Clear), + o Legrand - Celiane + o Schneider - Odace. +- Active power and energy consumption metering. +- Displays current load using multicolour LED frame (with FIBARO cover plate). +- Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 Authenticated with PRNG-based encryption. +- Works as Z-Wave signal repeater (all non-battery operated devices within the network will act as repeaters to increase reliability of the network). +- May be used with all devices certified with the Z-Wave Plus certificate and should be compatible with such devices produced by other manufacturers. + + FIBARO Walli Outlet is powered using DC power supply unit so it is always awake. + To add the device to the Z-Wave network manually: +1. Power the device. +2. Set the main controller in (Security/non-Security Mode) add mode (see the controller's manual). +3. Quickly, three times click one of the buttons. +4. If you are adding in Security S2 Authenticated, scan the DSK QR code or input the underlined part of the DSK (on the device label). +5. LED will start blinking yellow, wait for the adding process to end. +6. Adding result will be confirmed by the Z-Wave controller's message and the LED frame: + - Green - successful (non-secure, S0, S2 non-authenticated), + - Magenta - successful (Security S2 Authenticated), + - Red - not successful. + + To remove the device from the Z-Wave network: +1. Power the device. +2. Set the main controller into remove mode (see the controller's manual). +3. Quickly, three times click the button. +4. LED will start blinking yellow, wait for the removing process to end. +5. Successful removing will be confirmed by the Z-Wave controller's message and red LED colour. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3220/xml + + + + + + This parameter determines how the device will react in the event of power supply failure (e.g. power outage). + + + + + This function allows to turn off the controlled device in case of exceeding the defined power. Controlled device can be turned back on via button or sending a control frame. +0: function disabled, 10-36800: (1.0-3680.0W, step 0.1W) power threshold + + + + This parameter determines maximum active power. Exceeding it results in the LED frame flashing violet. Function is active only when parameter 11 is set to 8 or 9. +500-36800 (50.0-3680.0W, step 0.1W) - power threshold + + + This parameter defines the LED colour when the device is ON. + +When set to 8 or 9, LED frame colour will change depending on the measured power and parameter 10. Other colours are set permanently and do not depend on power consumption. + + + + + + + + + + + + + This parameter defines the LED colour when the device is OFF. + + + + + + + + + + + This parameter allows to adjust the LED frame brightness. + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. +1B: [MSB] Notification Type, 2B: Notification Status, 3B: Event/State Parameters, 4B: [LSB] action +0xX0: no action on output, 0xX1: turn ON, 0xX2: turn OFF, 0xX3: turn ON/OFF continuously, 0x0X: no action on LED frame, 0x1X: LED frame blinks red, 0x2X: LED frame blinks green, 0x4X: LED frame blinks blue, 0x8X: disable LED frame, 0xFX: LED frame LAPD signal (red-white-blue) + + + + This parameter defines duration of alarm sequence. When time set in this parameter elapses, alarm is cancelled, LED frame and relay restore normal operation, but do not recover state from before the alarm. + 0: Infinite, 1-32400: (1s-9h, 1s step) - Duration + + + + This parameter determines which actions will result in sending control frames to devices associated in 2nd group. + + + + + + This parameter determines upper power threshold for 2nd association group (paramter 45). Exceeding it will result in sending value set in parameter 47. Cannot be lower than DOWN threshold (parameter 48). +100-36800: (10-3680W, 0.1W step) - power threshold + + + + This parameter defines value sent to devices in 2nd association group when power exceeds UP threshold set in parameter 46 (using Basic Command Class). + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + This parameter determines lower power threshold for 2nd association group (parameter 45). Exceeding it will result in sending value set in parameter 49. +0-36700: (0-3670W, 0.1W step) - power threshold + + + + This parameter defines value sent to devices in 2nd association group when power exceeds UP threshold set in parameter 46 (using Basic Command Class). + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + This parameter determines whether the power measurements should include power consumed by the device itself. + + + + + This parameter defines minimal change (from the last reported) in measured power that results in sending new report. For loads under 50W the parameter is irrelevant, reports are sent every 5W change. +0: reporting on change disabled, 1-500: (1-500%, 1% step) minimal change + + + This parameter defines reporting interval for measured power. Periodic reports are independent from changes in value (parameter 61). +0: periodic reports disabled, 30-32400: (30s-9h, 1s step) time interval + + + This parameter defines minimal change (from the last reported) in measured energy that results in sending new report. +0: reporting on change disabled, 1-500: (0.01-5kWh, 0.01kWh step) minimal change + + + This parameter defines reporting interval for measured energy. Periodic reports are independent from changes in value (parameter 65). +0: periodic reports disabled, 30-32400: (30s-9h, 1s step) time interval + + + + + + + + + + diff --git a/openzwave/fibaro/fgwpe.xml b/openzwave/fibaro/fgwpe.xml new file mode 100644 index 00000000..9ccf6af3 --- /dev/null +++ b/openzwave/fibaro/fgwpe.xml @@ -0,0 +1,149 @@ + + + http://www.openzwave.com/device-database/010F:1000:0600 + images/fibaro/fgwpe.png + https://products.z-wavealliance.org/products/993/ + FIBARO Wall Plug + CEPT (Europe) + http://www.fibaro.com/manuals/en/FGWPE_F-101-Wall-Plug/FGWPE_F-101-Wall-Plug-en-2.1-2.3.pdf + FGWPE/F-101 + Fibaro Wall Plug is a universal, Z-Wave compatible, relay switch in +the form of a socket adapter. The Plug may be used to operate any +device up to 2,500W power output. The Plug features power +consumption measuring and uses a crystal LED ring to visualize the +current load by color changing illumination. +Fibaro Wall Plug may be operated using the service button located +on its casing, or via any Z-Wave compatible controller. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/993/xml + + + + + + + + + + + + Once activated, Wall Plug will keep a connected device constantly ON, will stop reacting to alarm frames and B-button push. "Always on" function turns the Plug into a power and energy meter. Also, connected device will not be turned off upon receiving an alarm frame from another Z-Wave device (parameter 35 will be ignored). In "Always on" mode, connected device may be turned off only after user defined power has been exceeded (parameter 70). In such a case, connected device can be turned on again by pushing the B-button or sending a control frame. By default, overload protection is inactive. Default setting: 1 + + + + + Define how will the Plug react after the power supply is back on. Default setting: 1 + + + + + Type of transmitted control frame for association group 1, activated via input IN1. The parameter allows to specify the type of alarm frame or to force transmission of control commands (BASIC_SET) + + + + + + + + + + Parameter defines how the Wall Plug will respond to alarms (device's status change) Default setting: 0. 0 - no reaction, 1 - turn on connected device. LED ring signals an alarm through defined time period (parameter 39) or until the alarm is cancelled. 2 - turn off connected device. LED ring signals an alarm through defined time period (parameter 39) or until the alarm is cancelled. 3 - cyclically change device state, each 1second. In alarm mode Wall Plug does not report status change, power changes, ignores alarm frames. After the defined time period has passed (parameter 39) or after the alarm cancellation, connected device is set to the previous state. NOTE: If "always on" function is active (parameter 1), this parameter's settings are ignored. + + + + + + + Wall Plug's alarm mode duration. If a device sending an alarm frame through the Z-Wave network sets alarm duration as well, this parameter's settings are ignored. Default setting: 600 + + + Parameter defines by how much power load must change, in percents, to be reported to the main controller, with the highest priority in the Z-Wave network. By default, Fibaro Wall Plug immediately sends power report if the power load changes by 80%. Default setting: 80 (%) + + + Parameter defines by how much power load must change, in percents, to be reported to the main controller. By default, Fibaro Wall Plug sends power report if the power load changes by 15%. By default such changes in power load may be reported up to 5 times per 30 seconds. Wall Plug sends 5 reports during time period specified in paramater 43. Default setting: 15 (%) + + + This parameter defines how frequently standard power reports (parameter 42) will be sent. By default Wall Plug sends up to 5 reports each 30 seconds, provided the power load changes by 15%. Default setting: 30 (s) + + + New, reported energy value is calculated based on last reported value. Default setting: 10 (0,1 kWh). Available settings: 1 - 254 (0,01kWh - 2,54kWh). Value of 255 - changes in consumed energy will not be reported. Reports will be sent only in case of polling. Default Setting: 10 (0,1 kWh) + + + Parameter defines time period between reports sent when changes in power load have not been recorded. By default, if power load changes have not been recorded, reports are sent every hour. Default setting: 3 600 (s), Available settings: 1 - 65534 (s). Value of 65535 - no periodic reports. Reports will be sent only in case of power load / energy consumption changes (parameters 40, 42, 43,45) or in case of polling. Default setting: 3600 + + + This parameter determines whether energy metering should include the amount of energy consumed by the Wall Plug itself. Results are being added to energy consumed by controlled device. Default setting: 0 + + + + + Lower power threshold, used in parameter 52. Default setting: 300 (30W) Available settings: 0 - 25000 (0,0W - 2500W) DOWN value cannot be higher than a value specified in parameter 51. Default setting: 300 (30W) + + + Upper power threshold, used in parameter 52. Default setting: 500 (50W) Available settings: 1 - 25000 (0,1W - 2500W) UP value cannot be lower than a value specified in parameter 50. Default setting: 500 (50W) + + + Parameter deifines the way 2nd association group devices are controlled, depending on the current power load. Default setting: 6. Available settings: 0 - function inactive, 1 - turn the associated devices on, once the power drops below DOWN value (parameter 50), 2 - turn the associated devices off, once the power drops below DOWN value (parameter 50), 3 - turn the associated devices on, once the power rises above UP value (parameter 51), 4 - turn the associated devices off, once the power rises above UP value (parameter 51), 5 - 1 and 4 combined. Turn the associated devices on, once the power drops below DOWN value (parameter 50). Turn the associated devices off, once the power rises above UP value (parameter 51). 6 - 2 and 3 combined. Turn the associated devices off, once the power drops below DOWN value (parameter 50). Turn the associated devices on, once the power rises above UP value (parameter 51). Default setting: 6 + + + + + + + + + + Function is active only when parameter 61 is set to 0 or 1. Default setting: 25000 (2500W) Available settings: 1000 - 32000 (100W - 3200W). Default setting: 25000 (2500W) + + + 0 - LED ring illumination colour changes in predefined steps, depending on power consumption changes, 1 - LED ring illumination colour changes continuously, using full spectrum of available colours, depending on power consumption changes. 2 - White illumination, 3 - Red illumination, 4 - Green illumination, 5 - Blue illumination, 6 - Yellow illumination, 7 - Cyan illumination, 8 - Magenta illumination, 9 - illumination turned off completely. Default setting: 1 + + + + + + + + + + + + + 0 - LED ring illumination colour takes on the color corresponding to the last measured power at the time when the device controlled was turn off, 1 - White illumination, 2 - Red illumination, 3 - Green illumination, 4 - Blue illumination, 5 - Yellow illumination, 6 - Cyan illumination, 7 - Magenta illumination, 8 - illumination turned off completely. Default setting: 8 + + + + + + + + + + + + 0 - No change in colour. LED ring illumination colour determined by parameters 61 or 62 settings, 1 - LED ring flashes red / blue / white (default), 2 - White illumination, 3 - Red illumination, 4 - Green illumination, 5 - Blue illumination, 6 - Yellow illumination, 7 - Cyan illumination, 8 - Magenta illumination, 9 - illumination turned off completely. Default setting: 1 + + + + + + + + + + + + + This function allows for turning off the controlled device in case of exceeding the defined power. Controlled device will be turned off even if "always on" function is active (parameter 1). Controlled device can be turned back on via B-button or sending a control frame. By default this function is inactive. Default setting: 65535 (6553,5W) Available settings: 10 - 65535 (1W - 6553,5W). Value higher than 32000 (3200W) turns the overload safety switch off, i.e. this functionality is turned off by default. Default setting: 65535 (6553,5W) + + + + + + + + + + + diff --git a/openzwave/fibaro/fgwpfzw5.xml b/openzwave/fibaro/fgwpfzw5.xml new file mode 100644 index 00000000..699d0de9 --- /dev/null +++ b/openzwave/fibaro/fgwpfzw5.xml @@ -0,0 +1,203 @@ + + + http://www.openzwave.com/device-database/010F:1001:0602 + images/fibaro/fgwpfzw5.png + https://products.z-wavealliance.org/products/1653/ + FGWPE/F-102 + Resetting the device is not the recommended way of removing the device from the +Z-Wave network. Use reset procedure only if the primary controller is missing or +inoperable. Certain device removal can be achieved by the procedure of removing +described in “Adding/ removing the device”on page 6. + +1) Make sure the device is powered. +2) Press and hold the B-button. +3) Wait for the LED ring to glow yellow (4th menu position). +4) Release the B-button. +5) Click the B-button once to confirm selection. +6) After few seconds the device will restart with factory settings, which is signalled with the red ring colour. + + + + + 1) Plug the device into a socket nearby the main Z-Wave controller. +2) The LED ring will glow green signalling being added (removing is not necessary otherwise). +3) Set the main Z-Wave controller into remove mode (see the controller’s manual). +4) Quickly, triple click the B-button located on the casing. +5) Wait for the removing process to end. +6) Successful removing will be confirmed by the Z-Wave controller. + + FIBARO Wall Plug E/F + Wakeup Description +FIBARO Wall Plug is powered with mains voltage so it is always awake. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2818/FGWPEF-102-EN-A-v2.1.pdf + FIBARO Wall Plug is a universal, Z-Wave Plus compatible, remotely controlled outlet adapter. This device may be applied wherever you want to control electrical devices with up to 2500W load. The Wall Plug is equipped with a power and energy metering function. It uses a LED ring to visualize the current load with colour changing illumination and operating mode. This is the smallest and most attractive device of this type available in the world. The Wall Plug may be operated using the B-button located on its casing or via any Z-Wave compatible controller. + +Main features: +• Compatible with any Z-Wave or Z-Wave Plus Controller. +• Supports protected mode (Z-Wave network security mode) with AES-128 encryption. +• Extremely easy installation - simply plug the device into the mains socket. +• Works as a Z-Wave signal repeater. +• Active power and energy consumption metering. +• Current value of the load and operating mode are indicated by the multi-colour LED ring. + + CEPT (Europe) + 1) Plug the device into a socket nearby the main Z-Wave controller. +2) The LED ring will glow red signalling not being added (remove the device otherwise). +3) Set the main Z-Wave controller into adding mode (see the controller’s manual). +4) Quickly, triple click the B-button located on the casing. +5) Wait for the adding process to end. +6) Successful adding will be confirmed by the Z-Wave controller. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1653/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2818/xml + + https://products.z-wavealliance.org/products/2818/ + FGWPE/F-102 + CEPT (Europe) + + + + + + + + + + + + + + Once activated, Wall Plug will keep a connected device constantly ON, will stop reacting to alarm frames and B-button push. "Always on" function turns the Plug into a power and energy meter. Also, connected device will not be turned off upon receiving an alarm frame from another Z-Wave device (parameter 31 will be ignored). In "Always on" mode, connected device may be turned off only after user defined power has been exceeded (parameter 3). In such a case, connected device can be turned on again by pushing the B-button or sending a control frame. By default, overload protection is inactive. Default setting: 0 + + + + + This parameter determines how the Wall Plug will react in the event of power supply failure (e.g. taking out from the electrical outlet). After the power supply is back on, the Wall Plug can be restored to previous state or remain switched off. This parameter is ignored in Always On mode - the device automatically turns ON after plugging it into the socket. Default setting: 1 + + + + + This function allows for turning off the controlled device in case of exceeding the defined power. Controlled device will be turned off even if "always on" function is active (parameter 1). Controlled device can be turned back on via B-button or sending a control frame. Available settings: 10 - 30000 (1,0W - 3000,0W step 0,1W). Default setting: 0 (function inactive) + + + This parameter determines the minimum percentage change in active power that will result in sending power report to the main controller with the highest priority in the Z-Wave network. By default, the Wall Plug immediately sends the power report if the power load changes by 80%. Available settings: 1-99:power change in percent, 100:reports are disabled. Default setting: 80 (80%) + + + This parameter determines the minimum percentage change in active power that will result in sending power report to the main controller Compared to parameter 10, the maximum number of reports sent is reduced (parameter 12) to 5 in a specified time interval. In addition, the frames are not sent in EXPLORE mode, which prevents overloading the Z-Wave network. By default changes in power load may be reported up to 5 times per 30 seconds, when power load changes by 15%. Available settings: 1-99:power change in percent, 100:reports are disabled. Default setting: 15 (15%) + + + This parameter defines how frequently standard power reports (parameter 11) will be sent. By default Wall Plug sends up to 5 reports each 30 seconds, provided the power load changes by 15%. Available setttings: 5-600 (in seconds). Default setting: 30 (s) + + + This parameter specifies the minimum change in energy consumption (in relation to the previously reported), that will result in sending a new report. Available settings: 1-500 (0,01kWh - 5kWh). 0 - energy reports inactive. Default Setting: 10 (0,1 kWh) + + + This parameter defines time period between reports sent when changes in power load have not been recorded or if changes are insignificant (not exceeding values of parameters 20, 21 and 23). By default reports are sent every hour. Available settings: 5 - 32400 (s). 0 - periodic reports inactive. Reports will be sent only in case of power load / energy consumption changes (parameters 20,21,23) or in case of polling. Default setting: 3600 + + + This parameter determines whether energy metering should include the amount of energy consumed by the Wall Plug itself. Results are being added to energy consumed by controlled device. Default setting: 0 + + + + + Controlling devices with the B-Button. Control as the Wall Plug: switching the Wall Plug on switch the devices on (parameter 24) switching the Wall Plug off switch the devices off (parameter 24) This parameter is inactive in Always On mode (parameter 1). Default setting: 0 + + + + + Lower power threshold, used in parameter 23. Available settings: 0 - 24900 (0,0W - 2490,0W step 0,1W) DOWN value cannot be higher than a value specified in parameter 22. Default setting: 300 (30W) + + + Upper power threshold, used in parameter 23. Available settings: 100 - 25000 (10,0W - 2500,0W) UP value cannot be lower than a value specified in parameter 21. Default setting: 500 (50W) + + + Parameter defines the way 3th association group devices are controlled, depending on the actual measured power(as parameter 21 and 22 settings). Available settings: 1 - turn the associated devices ON, once the power drops below DOWN value (parameter 21), 2 - turn the associated devices OFF, once the power drops below DOWN value (parameter 21), 3 - turn the associated devices ON, once the power rises above UP value (parameter 22), 4 - turn the associated devices OFF, once the power rises above UP value (parameter 22), 5 - combination of 1 and 4. Turn the associated devices ON, once the power drops below DOWN value (parameter 21). Turn the associated devices OFF, once the power rises above UP value (parameter 22). 6 - combination of 2 and 3. Turn the associated devices OFF, once the power drops below DOWN value (parameter 21). Turn the associated devices ON, once the power rises above UP value (parameter 22). Default setting: 6 + + + + + + + + + The value of BASIC SET command frame sent to the devices associated in On/Off association groups (2, 3). On/Off (Button) association group - in accordance with parameter 20. On/Off (Power) association group - in accordance with parameter 23. Available settings: 0-99 and 255. Default setting: 255 + + + Define Z-Wave network alarms to which the Wall Plug will respond. + + + + + + + + + + This parameter defines how the Wall Plug will respond to alarms (device's status change). In case of values 1 or 2 the Wall Plug is operating normally and LED ring signals an alarm through time defined in parameter 32 or until the alarm is cancelled. In case of values 5 to 50 the Wall Plug does not report status change, power changes, ignores BASIC SET command frames. After time defined in parameter 32 or after the alarm cancellation, connected device is set to the previous state.. 0- no reaction 1-turn connected device on 2-turn connected device off 5-50(0,5-50,0s step 0,1s)-cyclically change device state with set period. Default setting:0-no reaction + + + This parameter specifies the duration of alarm state. If a device sending an alarm frame through the Z-Wave network sets alarm duration as well, this settings are ignored. Available settings 1-32400(s) Default setting: 600 + + + Function is active only when parameter 41 is set to 0 or 1. Available settings: 1000 - 30000 (100,0W - 3000,0W, step 0,1W). Default setting: 25000 (2500W) + + + 0 - Illumination turned off completely, 1 - LED ring illumination colour changes continuously depending on active power, 2 - LED ring illumination colour changes in steps, depending on active power, 3 - White illumination, 4 - Red illumination, 5 - Green illumination, 6 - Blue illumination, 7 - Yellow illumination, 8 - Cyan illumination, 9 - Magenta illumination. Default setting: 1 + + + + + + + + + + + + + 0 - Illumination turned off completely, 1 - LED ring is illuminated with a colour corresponding to the last measured power, before the controlled device was turned off, 3 - White illumination, 4 - Red illumination, 5 - Green illumination, 6 - Blue illumination, 7 - Yellow illumination, 8 - Cyan illumination, 9 - Magenta illumination. Default setting: 0 + + + + + + + + + + + + 0 - illumination turned off completely, 1 - No change in colour. LED ring illumination colour determined by parameters 41 or 42 settings, 2 - LED ring flashes red/blue/white (default), 3 - White illumination, 4 - Red illumination, 5 - Green illumination, 6 - Blue illumination, 7 - Yellow illumination, 8 - Cyan illumination, 9 - Magenta illumination. Default setting: 2 + + + + + + + + + + + + + This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. This parameter does not apply to 1st Lifeline group. Available settings: 0-3: 0 - none of the groups are sent as secure; 1 - 2nd group sent as secure; 2 - 3rd group sent as secure; 3 - 2nd and 3rd group sent as secure; Default setting: 3 + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgwpg111.xml b/openzwave/fibaro/fgwpg111.xml new file mode 100644 index 00000000..82ce297d --- /dev/null +++ b/openzwave/fibaro/fgwpg111.xml @@ -0,0 +1,243 @@ + + + http://www.openzwave.com/device-database/010F:2000:1701 + images/fibaro/fgwpg111.png + https://products.z-wavealliance.org/products/2854/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2899/FGWPG-111-EN-T-v.0.2.pdf + To remove the device from the Z-Wave network: +1. Plug the device into a socket nearby the main Z-Wave controller. +2. The LED frame will glow green signaling being added (removing is not necessary otherwise). +3. Set the main controller into remove mode. +4. Quickly, triple click the button located on the casing. +5. Wait for the removing process to end. +6. Successful removing will be confirmed by the Z-Wave controller’s message. + + FIBARO Wall Plug is powered with mains voltage so it is always awake. + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. +1. Make sure the device is powered. +2. Press and hold the button. +3. Wait for the LED frame to glow yellow (3rd menu position). +4. Release the button. +5. Click the button once to confirm selection. +6. After few seconds the device will restart with factory settings, which is signaled with the red frame color. + +Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use the reset procedure only if the primary controller is missing or inoperable. + Wall Plug UK + FIBARO Wall Plug is a remotely controlled plug-in switch with the ability to measure power and energy consumption. It uses a LED frame to visualize the current load and operating mode with color changing illumination. FIBARO Wall Plug makes it possible to control electrical devices in a convenient and maintenance-free way. +Main features of FIBARO Wall Plug: +- Compatible with any Z-Wave or Z-Wave+ Controller. +- Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption. +- Extremely easy installation - simply plug the device into the mains socket. +- Works as a Z-Wave signal repeater. +- Active power and energy consumption metering for plugged device. +- Current value of the load and operating mode are indicated by the multi-color LED frame. + + FGWPB-111 + To add the device to the Z-Wave network: +1. Plug the device into a socket nearby the main Z-Wave controller. +2. The LED frame will glow red signaling not being added (reset or remove the device otherwise). +3. Set the main controller in (security/non-security) add mode. +4. Quickly, triple click the button located on the casing. +5. If you are adding in S2 authenticated mode, type in the device pin code (underlined part of the public key available on the device or in the manual). +6. Wait for the adding process to end. +7. Successful adding will be confirmed by the Z-Wave controller’s message. + + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2854/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2899/xml + + https://products.z-wavealliance.org/products/2899/ + FGWPG-111 + CEPT (Europe) + + + + + + + + + + + This parameter determines how the Wall Plug will react in the event of power supply failure (e.g. taking out from the electrical outlet). + After the power supply is back on, the Wall Plug can be restored to previous state or remain switched off. + This parameter is ignored in Always On mode - the device automatically turns ON after plugging it into the socket. + Default setting: 1 + + + + + + This function allows to turning off the controlled device in case of exceeding the defined power. + Controlled device can be turned back on via button or sending a control frame. + Available settings: 10 - 30000 (1,0W - 3000,0W step 0,1W). + Default setting: 0 (function inactive) + + + + This parameter determines the minimum percentage change inactive power consumption (in relation to the previously reported) that will result in sending new power report. + Available settings: 1-100. 0 - power reports inactive. + Default Setting: 15 (%) + + + + This parameter determines the minimum change in energy consumption (in relation to the previously reported), that will result in sending a new report. + Available settings: 1-500 (0,01kWh - 5kWh). 0 - energy reports inactive. + Default Setting: 10 (0,1 kWh) + + + + This parameter defines time period between reports sent when changes in power load have not been record if changes are smaller than defined in parameter 11. + By default reports are sent every hour. + Available settings: 0 - 32400 (s). 0 - periodic reports inactive. + Default setting: 3600 + + + + This parameter defines time period between reports sent when changes in power load have not been recorded or if changes are smaller than in paramater 11. + By default reports are sent every hour. + Available settings: 0 - 32400 (s). 0 - periodic reports inactive. + Default setting: 3600 + + + + This parameter determines whether power metering should include the amount of power consumed by the Wall Plug itself. + Results are being added to the value of power consumed by controlled device. + Default setting: 0 Inactive + + + + + + Upper power threshold, used in parameter 23. Up value cannot be lower than a value specified in parameter 22. + Available settings: 100 - 30000 (10,0W - 30000,0W). + Default setting: 500 (50W) + + + + Lower power threshold, used in parameter 23. + DOWN value cannot be higher than a value specified in parameter 21. + Available settings: 0 - 29900 (0,0W - 2990,0W step 0,1W). + Default setting: 300 (30W) + + + + This parameter defines the way that 3rd association group devices are controlled. + Depends on the actual measured power(according to parameters 21 and 22 settings). + Default setting: 3 + + + + + + + The value of BASIC SET command frame sent to the devices associated in 2nd group On/Off (Button) when turning the device ON using the button. + Available settings: 0-99 or 255. + Default setting: 255 + + + + The value of BASIC SET command frame sent to the devices associated in 2nd group On/Off (Button) when turning the device OFF using the button. + Available settings: 0-99 or 255. + Default setting: 0 + + + + The value of BASIC SET command frame sent to the devices associated in 3rd group On/Off (Power) if power exceeded value of parameter 21. + Available settings: 0-99 or 255. + Default setting: 255 + + + + The value of BASIC SET command frame sent to the devices associated in 3rd group On/Off (Power) if power dropped below value of parameter 22. + Available settings: 0-99 or 255. + Default setting: 0 + + + + Define Z-Wave network alarms to which the Wall Plug will respond. + + + + + + + + + + This parameter defines how the Wall Plug will respond to alarms (device's status change). + In case of values 1 or 2 the Wall Plug is operating normally and LED frame signals an alarm through time defined in parameter 32 or until the alarm is cancelled. + In case of values 5 to 50 the Wall Plug does not report status change, power changes, ignores BASIC SET command frames. + After time defined in parameter 32 or after the alarm cancellation, connected device is set to the previous state. + 0 - no reaction 1-turn connected device on 2-turn connected device off 5-50(0,5-50,0s step 0,1s)-cyclically change device state with set period. + Default setting:0-no reaction + + + + This parameter specifies the duration of alarm state. + If a device sending an alarm frame through the Z-Wave network sets alarm duration as well, this settings are ignored. + Available settings 1-32400(s) + Default setting: 600 + + + + This parameter determines maximum active power value, which when exceeded, causes the LED frame to flash violet. Function is active only when parameter 41 is set to 1 or 2. + Available settings: 1000 - 30000 (100,0W - 3000,0W, step 0,1W). + Default setting: 30000 (3000W) + + + + When set to 1 or 2, LED frame colour will change depending on active power and parameter 40. + Other colours are set permanently and do not depend on power consumption + + + + + + + + + + + + + + This parameter defines the illumination colour after turning off. + + + + + + + + + + + + This parameter defines the illumination colour in case of Z-Wave alarm. + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/fibaro/fgwr111.xml b/openzwave/fibaro/fgwr111.xml new file mode 100644 index 00000000..c9fd31ee --- /dev/null +++ b/openzwave/fibaro/fgwr111.xml @@ -0,0 +1,400 @@ + + + Walli Roller Shutter + FIBARO Walli Roller Shutter is a smart wall switch designed to control motors of roller blinds, awnings, venetian blinds and other single phase, AC powered devices via Z-Wave network. It measures active power and energy consumed by the controlled load. + http://www.openzwave.com/device-database/010F:1000:1D01 + https://www.fibaro.com/en/products/smart-switches-and-outlets-walli-roller-shutter/ + https://manuals.fibaro.com/walli-roller-shutter/ + images/fibaro/fgwr111.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/3396/FGWREU-111-T-EN-0.19.pdf + FIBARO Walli Roller Shutter is powered with mains voltage so it is always awake. + + To add the device to the Z-Wave network manually: + 1. Power the device. + 2. Set the main controller in (Security/non-Security Mode) add mode (see the controller's manual). + 3. Quickly, three times click one of the buttons. + 4. If you are adding in Security S2 Authenticated, scan the DSK QR code or input the underlined part of the DSK (label on the bottom of the box). + 5. LED will start blinking yellow, wait for the adding process to end. + 6. Adding result will be confirmed by the Z-Wave controller's message and the LED frame: + - Green: successful (non-secure, S0, S2 non-authenticated), + - Magenta: successful (Security S2 Authenticated), + - Red: not successful. + + + To remove the device from the Z-Wave network: + 1. Power the device. + 2. Set the main controller into remove mode (see the controller's manual). + 3. Quickly, three times click one of the buttons. + 4. LED will start blinking yellow, wait for the removing process to end. + 5. Successful removing will be confirmed by the Z-Wave controller's message and red LED colour. + + + Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. Resetting to factory defaults does not reset energy consumption memory. + 1. Quickly, three times click, then press and hold one of the buttons to enter the menu. + 2. Release button when the device glows yellow. + 3. Quickly click the button to confirm. + 4. After few seconds the device will be restarted, which is signalled with red LED colour. + + https://products.z-wavealliance.org/products/3396 + CEPT (Europe) + FGWREU-111 + + Initial Metadata Import from Z-Wave Alliance Database + + + + + + + This parameter defines the LED colour when the motor is running. + + + + + + + + + + + + This parameter defines the LED colour when the device motor is not running. + + + + + + + + + + + + + This parameter allows to adjust the LED frame brightness. + 0 - LED disabled + 1-100 - (1-100% brightness) + + + + + + This parameter allows reversing the operation of the buttons. + + 0 - default (1st button UP, 2nd button DOWN) + 1 - reversed (1st button DOWN, 2nd button UP) + + + + + + + + This parameter allows reversing the operation of Q1 and Q2 without changing the wiring (e.g. in case of invalid motor connection). + + 0 - default (Q1 - UP, Q2 - DOWN) + 1 - reversed (Q1 - DOWN, Q2 - UP) + + + + + + + + This parameter determines to which alarm frames and how the device should react. + The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. + + 1B [MSB] - Notification Type + 2B - Notification Status + 3B - Event/State Parameters + 4B [LSB] - action: + 0x00 - no action, + 0xX1 - open, + 0xX2 - close, + 0x0X - no action on LED frame, + 0x1X - LED frame blinks red, + 0x2X - LED frame blinks green, + 0x4X - LED frame blinks blue, + 0x8X - dis- able LED frame, + 0xFX - LED frame LAPD signal (red-white-blue) + + Default value: [0x00, 0x00, 0x00, 0x00] (disabled) + + + + + + This parameter determines to which alarm frames and how the device should react. + The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. + + 1B [MSB] - Notification Type + 2B – Notification Status + 3B – Event/State Parameters + 4B [LSB] – action: + 0x00 - no action, + 0xX1 - open, + 0xX2 - close, + 0x0X - no action on LED frame, + 0x1X - LED frame blinks red, + 0x2X - LED frame blinks green, + 0x4X - LED frame blinks blue, + 0x8X - dis- able LED frame, + 0xFX - LED frame LAPD signal (red-white-blue) + + Default value: [0x05, 0xFF, 0x00, 0x00] (Water Alarm, any notification, no action) + + + + + + This parameter determines to which alarm frames and how the device should react. + The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. + + 1B [MSB] - Notification Type + 2B - Notification Status + 3B - Event/State Parameters + 4B [LSB] - action: + 0x00 - no action, + 0xX1 - open, + 0xX2 - close, + 0x0X - no action on LED frame, + 0x1X - LED frame blinks red, + 0x2X - LED frame blinks green, + 0x4X - LED frame blinks blue, + 0x8X - dis- able LED frame, + 0xFX - LED frame LAPD signal (red-white-blue) + + Default value: [0x01, 0xFF, 0x00, 0x00] (Smoke Alarm, any notification, no action) + + + + + + This parameter determines to which alarm frames and how the device should react. + The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. + + 1B [MSB] - Notification Type + 2B - Notification Status + 3B - Event/State Parameters + 4B [LSB] - action: + 0x00 - no action, + 0xX1 - open, + 0xX2 - close, + 0x0X - no action on LED frame, + 0x1X - LED frame blinks red, + 0x2X - LED frame blinks green, + 0x4X - LED frame blinks blue, + 0x8X - dis- able LED frame, + 0xFX - LED frame LAPD signal (red-white-blue) + + Default value: [0x02, 0xFF, 0x00, 0x00] (CO Alarm, any notification, no action) + + + + + + This parameter determines to which alarm frames and how the device should react. + The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. + + 1B [MSB] - Notification Type + 2B - Notification Status + 3B - Event/State Parameters + 4B [LSB] - action: + 0x00 - no action, + 0xX1 - open, + 0xX2 - close, + 0x0X - no action on LED frame, + 0x1X - LED frame blinks red, + 0x2X - LED frame blinks green, + 0x4X - LED frame blinks blue, + 0x8X - dis- able LED frame, + 0xFX - LED frame LAPD signal (red-white-blue) + + Default value: [0x02, 0xFF, 0x00, 0x00] (CO Alarm, any notification, no action) + + + + + + This parameter defines duration of alarm sequence. + When time set in this parameter elapses, alarm is cancelled, LED frame and relay restore normal operation, but do not recover state from before the alarm. + + 0 – infinite + 1-32400 (1s-9h, 1s step) – duration + + Default value: 600 (10min) + + + + + + This parameter determines which actions result in sending scene IDs assigned to them. + Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent). + Enabling scenes for triple click disables entering the device in learn mode by triple clicking. + + 1 - Key pressed 1 time + 2 - Key pressed 2 times + 4 - Key pressed 3 times + 8 - Key hold down and key released + + Default value: 0 (no scenes) + + + + + + This parameter determines which actions result in sending scene IDs assigned to them. + Values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent). + Enabling scenes for triple click disables entering the device in learn mode by triple clicking. + + 1 - Key pressed 1 time + 2 - Key pressed 2 times + 4 - Key pressed 3 times + 8 - Key hold down and key released + + Default value: 0 (no scenes) + + + + + This parameter determines whether the power measurements should include power consumed by the device itself. + + + + + + + This parameter defines minimal change (from the last reported) in measured power that results in sending new report. + For loads under 50W the parameter is irrelevant, report are sent every 5W change. + + 0 - reporting on change disabled + 1-500 (1-500%, 1% step) – minimal change + + Default value: 15 (15%) + + + + + + This parameter defines reporting interval for measured power. + Periodic reports are independent from changes in value (parameter 61). + + 0 – periodic reports disabled + 30-32400 (30s-9h, 1s step) – time interval + + Default value: 3600 (1h) + + + + + + This parameter defines minimal change (from the last reported) in measured energy that results in sending new report. + + 0 - reporting on change disabled + 1-500 (0.01-5kWh, 0.01kWh step) – minimal change + + Default value: 10 (0.1kWh) + + + + + + This parameter defines reporting interval for measured energy. + Periodic reports are independent from changes in value (parameter 65). + + 0 – periodic reports disabled + 30-32400 (30s-9h, 1s step) – time interval + + Default value: 3600 (1h) + + + + + + By setting this parameter to 2 the device enters the calibration mode. + The parameter relevant only if the device is set to work in positioning mode (parameter 151 set to 1 or 2). + + + + + + + + This parameter allows adjusting operation according to the connected device. + + + + + + + + + For Venetian blinds (parameter 151 set to 2) the parameter determines time of full turn cycle of the slats. + The parameter is irrelevant for other modes. + + 0-65535 (0 - 655.35s, every 0.01s) - time of turn + + Default value: 150 (1.5 seconds) + + + + + + For Venetian blinds (parameter 151 set to 2) the parameter determines slats positioning in various situations. + The parameter is irrelevant for other modes. + + + + + + + + + The parameter determines the time after which the motor will be stopped after end switch contacts are closed. + + 1-255 (0.1s - 25.5 seconds) + + + + + + Power threshold interpreted as reaching a limit switch. + + 1-255 (1-255W) - report interval + 0 - no detection + + Default value: 10 (10W) + + + + + + This parameter determines the time needed for roller blinds to reach the top. + For modes with positioning value is set automatically during calibration, otherwise, it must be set manually. + + 1-65535 (0.01 - 655.35 seconds) + + Default value: 6000 (60 seconds) + + + + + This parameter determines the time needed for roller blinds to reach the bottom. + For modes with positioning value is set automatically during calibration, otherwise, it must be set manually. + + 1-65535 (0.01 - 655.35 seconds) + + Default value: 6000 (60 seconds) + + + + + + + + + + + + + diff --git a/openzwave/firstalert/zcombo-g.xml b/openzwave/firstalert/zcombo-g.xml new file mode 100644 index 00000000..e32434b3 --- /dev/null +++ b/openzwave/firstalert/zcombo-g.xml @@ -0,0 +1,48 @@ + + + ZCombo-G Smoke/CO Alarm + http://www.openzwave.com/device-database/0138:0003:0001 + https://products.z-wavealliance.org/products/3886 + images/firstalert/zcombo-g.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3886/User_Manual_M08-0456-173833_D2.pdf + The Z-Wave Smoke/CO alarm can be implemented in residential and institutional applications. Installation settings include sleeping areas within hospitals, hotels, motels, dormitories and other multi-family dwellings that are defined in standard NFPA 101. The First Alert ZCOMBO-G Smoke and Carbon Monoxide Detector has been fully tested and complies with UL217, UL2034, CSFM, NFPA 720, NFPA 101 and other agencies that model their codes after the above agencies. The combination alarm meets building codes that require the use of a battery operated Z-Wave wireless Smoke and CO detector. This First Alert Z-Wave Combination Alarm includes silence features and meets the model building codes published by the ICC. + The First Alert Z-Wave Combo Alarm includes: an insect screened photoelectric smoke sensing chamber, electrochemical carbon monoxide sensor, 85dB horn, supervised 3V (2 AA batteries) power supply, full function test switch and a silence feature. + The First Alert Z-Wave Enabled Battery Smoke & Carbon Monoxide Combo Alarm includes a battery drawer that prevents battery removal and tamper resistant locking pins that lock the alarm to the mounting bracket. This First Alert Combination Alarm is an ideal fit for any number of applications that include apartments, dormitories, and hotels. Designed for wall or ceiling mounting, this alarm includes all of the required mounting anchors and screws needed for easy installation. + + To manual wake-up the device, slide the battery door open wait for ~5 seconds and then slide the battery drawer closed. Upon power-up, the device will send the wake-up notification. + 1. Slide battery door open. +2. Insert batteries checking the correct orientation. +3. Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button. + 1. Slide battery door open. +2. Insert batteries checking the correct orientation. +3. Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button. + If the device is powered up with the test button held down for 10+ seconds, the device will reset all Z-Wave settings and leave the network. +Upon completion of the Reset operation, the LED will glow and the horn will sound for ~1 second. +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + https://products.z-wavealliance.org/products/3886/ + U.S. / Canada / Mexico + ZCOMBO + + Copy from ZCOMBO, update based on Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3886/xml + + + + + ZCOMBO will send the message over SuperVision Command Class and it will wait for the SuperVision report from the Controller for the SuperVision report timeout time. + + + If the SuperVision report is not received within the SuperVision report timeout time, the ZCOMBO will retry sending the message again. Upon exceeding the max retry, the ZCOMBO device will send the next message available in the queue. + + + Before retrying the message, ZCOMBO will wait for the SuperVision wait time. Actual wait time is calculated using the formula: Wait Time = SuperVision wait time base-value + random-value + (attempt-count x 5 seconds). The random value will be between 100 and 1100 milliseconds. + + + + + + + + + diff --git a/openzwave/firstalert/zcombo.xml b/openzwave/firstalert/zcombo.xml new file mode 100644 index 00000000..b7c12dfa --- /dev/null +++ b/openzwave/firstalert/zcombo.xml @@ -0,0 +1,30 @@ + + + http://www.openzwave.com/device-database/0138:0002:0001 + images/firstalert/zcombo.png + https://products.z-wavealliance.org/products/862/ + Smoke and Carbon Monoxide Alarm + ZCOMBO + U.S. / Canada / Mexico + Smoke/CO Alarm + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/862/xml + + + + + + + + Causes the device to send double alarm messages. + + + + + + + + + + + diff --git a/openzwave/firstalert/zsmoke.xml b/openzwave/firstalert/zsmoke.xml new file mode 100644 index 00000000..d086080b --- /dev/null +++ b/openzwave/firstalert/zsmoke.xml @@ -0,0 +1,29 @@ + + + images/firstalert/zsmoke.png + https://products.z-wavealliance.org/products/863/ + Smoke Alarm + ZSMOKE + U.S. / Canada / Mexico + Smoke Alarm + + Initial release - modified from zcombo + + + + + + + + Causes the device to send double alarm messages. + + + + + + + + + + + diff --git a/openzwave/followgood/swz-1002.xml b/openzwave/followgood/swz-1002.xml new file mode 100644 index 00000000..454f3abc --- /dev/null +++ b/openzwave/followgood/swz-1002.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/0137:0002:3001 + images/followgood/swz-1002.png + https://products.z-wavealliance.org/products/830/ + Binary Power Switch + CEPT (Europe) + Power Switch + SWZ-1002 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/830/xml + + + diff --git a/openzwave/forest/fs2z5232000002.xml b/openzwave/forest/fs2z5232000002.xml new file mode 100644 index 00000000..5582192c --- /dev/null +++ b/openzwave/forest/fs2z5232000002.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/0207:0100:0027 + images/forest/fs2z5232000002.png + https://products.z-wavealliance.org/products/3185/ + Press configuration button 3 times. LED3 is ON. +Press and hold once more for 4 seconds. + Press configuration button 25x times. LED 1 is ON. Press and hold once more for 4 seconds to confirm. +Please use this procedure only when your network primary controller is missing or otherwise inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3185/Installing_the_FOREST_SHUTTLE_S-M-L _Z-wave_V1_6EN.pdf + FS2Z5232000007 + CEPT (Europe) / U.S. / Canada / Mexico / India / Australia / New Zealand + Forest Shuttle L Z-wave, Shuttle S Z-wave (US) and Forest motorized curtain track systems (FMS) make an unbeatable combination when it comes to noiseless operated motorized curtains. The smooth and silent running curtain track system can, in addition to remote operation, also be operated by hand. Thanks to Forest’s special Touch Impulse Technology, a gentle pull on the curtain is enough to activate the motor. The Forest Shuttle L Z-wave, Shuttle S Z-Wave (US) makes sure that your curtains will always hang beautifully smooth and supple. Opened as well as closed! +• Touch Impulse Technology, gently pulling the curtain will activate the motor. +• Integrated Emergency Control ensures manual operation of the curtain in case of power failure. +• Modular motor, different modules can be attached for various control options: Radio Frequency, Switch, Infrared, Domotics, Building/Hotel Automation, Serial Communication, Z-Wave, etc. +• Forest Shuttle L Z-Wave and Shuttle S Z-wave (US) will have an internal Z-Wave receiver and BUS connection. +• Silent motor, speeds: 14 and 17 cm/sec., with slow start and slow stop. +• Full automatic setting of the limits. +• Stack-back position programmable to every desired setting. +• Forest Shuttle L Z-Wave and Shuttle S Z-wave (US) have an integrated power supply. +• Motor pulley connects motor and FMS track. Also available in upside down version to conceal the motor into the ceiling. +• Available track lenghts: 5.80 meters and 7.00 meters. FMS track and components available in white, grey and black. + + Forest Shuttle LZ ANZ + Press configuration button 3 times. LED3 is ON. +Press and hold once more for 4 seconds. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1294/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2548/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3184/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3185/xml + + + + + + + + + + + + diff --git a/openzwave/fortrezz/fmi.xml b/openzwave/fortrezz/fmi.xml new file mode 100644 index 00000000..bc05e185 --- /dev/null +++ b/openzwave/fortrezz/fmi.xml @@ -0,0 +1,62 @@ + + + http://www.openzwave.com/device-database/0084:0110:0473 + images/fortrezz/fmi.png + https://products.z-wavealliance.org/products/1690/ + The FMI will send the Node information frame when the switch is briefly pressed. This is primarily used for inclusion; however, status information is also sent after a button press. + + FMI + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1690/User Manual FMI - 29Feb2016.pdf + 1) Set up the inclusion mode at the controller; 2) Briefly press the switch once and the controller will indicate the unit has been included in the network. Also, the LED will blink when the inclusion completes. + U.S. / Canada / Mexico + Device Reset to Factory Defaults – Press and hold the button for 15 or more seconds and then release. This can be done while the device is either in or out of a network, but not while in NWI mode. CAUTION – When a reset is done in-network, the device will no longer be in the network. All configurations and associations will be set to default. + + Information is power! With flow meter, you have the power to automate and manage water consumption and leak detection in your home or building. This is an integral part to a complete water management solution! Flow meter tracks water usage and reports in gallons. Track your households water usage! Drill into reports and find out where your peak consumption is and make changes to reduce your water bills. Flow meter also tells you if water is flowing or not. It knows if the flow is small (like a toilet running) or large (a garden hose left on). This can be used to detect leaks, faulty appliances, or fixtures left on. To add to it's capabilities, flow meter checks the temperature of the nearby surroundings to make sure the pipes don't freeze by sending you temperature reports. There's also a backup battery just in case power is interrupted. You wont have to worry about lost data or a lack of leak monitoring. Plumbed on the water main, flow meter is sure to be a valuable part of your home automation & leak prevention system. + + 1) Set up the exclusion mode at the controller; 2) Briefly press the switch once and then release. The controller will indicate the unit has been removed from the network. The LED will blink when the exclusion completes. + + Flow Meter + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1690/xml + + + + + + + 246 to 69 -10 to 69C + + + 247 to 70 -9 to 70C + + + + 0 TO 2147483647 count rolls over at 99,999,999 + + + + + 0 to 2,550 seconds + + + + + Low vs High flow 0 to 65535 + + + + MultiLevel Sensor Report vs Notification Toggle + + + + + + + + + + + + + + diff --git a/openzwave/fortrezz/fts05p.xml b/openzwave/fortrezz/fts05p.xml new file mode 100755 index 00000000..cdb48772 --- /dev/null +++ b/openzwave/fortrezz/fts05p.xml @@ -0,0 +1,78 @@ + + + FTS05P Flood & Temperature Sensor + Water damages are caused by leaking pipes and faulty appliances. Place sensors in areas near water consuming appliances. If a leak occurs, water will puddle and wet the sensor, triggering an alarm. + http://www.openzwave.com/device-database/0084:020a:00a3 + https://www.fortrezz.com/shop/flood-sensor-w-probe + https://www.fortrezz.com/support + images/fortrezz/fts05p.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2458/User%20Manual%20FTS05-FTS05P.pdf + To initiate manual wakeup, press the program button once, while in network. Device stays awake for 10 seconds or longer if communicating with the controller. + 1) Set up the Add/Inclusion mode at the controller; 2) Briefly press the switch once and the controller will indicate the unit has been added into the network. Also, the LED will blink 2 quick blinks when complete. + 1) Set up the Remove/Exclusion mode at the controller; 2) Press and hold the switch for approx. 2 seconds and then release. The controller will indicates the unit has been removed from the network. The LED will blink 4 quick blinks when complete. + Reset the device to factory Defaults - Press and hold the program button for longer than 15 seconds. When complete, the LED will flash approx. 30 times. This can be done while the device is either in or out of a network. Please use this procedure only when the network primary controller is missing or otherwise inoperable. Caution – When this is done in-network, the device will no longer be in the network and all configurations and associations will be set to default. + https://products.z-wavealliance.org/products/2458 + U.S. / Canada / Mexico + FTS05P + + Initial entry from Z-Wave Alliance Database and from Manufacturer's website. + + + + + + Use this to change the low temperature alarm threshold. Set the range between -10 and 69 deg C. + Note: The user configuration value is a positive decimal integer 0 through 255, but the device + interprets the value as 8-bit Two's complement. Examples: + -10 in Two's complement is 246 decimal (0xF6). + -2 in Two's complement is 254 decimal (xFE) + -1 in Two's complement is 255 decimal (xFF) + 0 in Two's complement is 0 decimal (0x00). + 69 in Two's complement is 69 decimal (0x45). + Thus the valid range the user may enter is 0-69 and 246-255. + + + + + Use this to change the high temperature alarm threshold. Set the range between -9 and 70 deg C. + Note: The user configuration value is a positive decimal integer 0 through 255, but the device + interprets the value as 8-bit Two's complement. Examples: + -9 in Two's complement is 247 decimal (0xF7). + -2 in Two's complement is 254 decimal (xFE) + -1 in Two's complement is 255 decimal (xFF) + 0 in Two's complement is 0 decimal (0x00). + 70 in Two's complement is 70 decimal (0x46). + Thus the valid range the user may enter is 0-70 and 247-255. + + + + + Default is set as a Normally DRY sensor. Use this to switch to Normally WET sensor. + The device only accepts one of two possible values: + 0 (0x00) - Normally Dry (default). + 240 (0xF0) - Normally Wet. + + + + + Use this to send basic set ON or Basic Set OFF when an alarm is detected. + The device only accepts one of two possible values: + 0 (0x00) - For sending basic set OFF when alarm detected. + 240 (0xF0) - For sending basic Set ON (default) when alarm detected. + + + + + + + + + + + + + + + + + diff --git a/openzwave/fortrezz/gdc1_fortrezz_1501.xml b/openzwave/fortrezz/gdc1_fortrezz_1501.xml new file mode 100644 index 00000000..592211f2 --- /dev/null +++ b/openzwave/fortrezz/gdc1_fortrezz_1501.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/0084:0111:0513 + images/fortrezz/gdc1_fortrezz_1501.png + https://products.z-wavealliance.org/products/1242/ + GDC1_FortrezZ_1501 + FortrezZ GDC1 + The GDC1 Module is an interface / bridge / siren strobe combination module with On/Off Switch outputs. + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1242/xml + + + diff --git a/openzwave/fortrezz/mimo2plus.xml b/openzwave/fortrezz/mimo2plus.xml new file mode 100644 index 00000000..4c0e66bb --- /dev/null +++ b/openzwave/fortrezz/mimo2plus.xml @@ -0,0 +1,86 @@ + + + http://www.openzwave.com/device-database/0084:0204:0463 + images/fortrezz/mimo2plus.png + https://products.z-wavealliance.org/products/1893/ + Device Reset to Factory Defaults – Press and hold the program button for 15 seconds and then release. This can be done while the device is either in or out of a network. CAUTION – When this is done in-network, the device will no longer be in the network and all configurations and associations will be set to default. +Please use this procedure only when your network primary controller is missing or otherwise inoperable. + The MIMO2+ module provides two voltage inputs and two relay outputs (either can be wired normally open or normally closed). +Z-Wave™ messages can be used to read the inputs and control the outputs. The inputs are very configurable for different trigger conditions and can even be mapped to control the outputs. The module includes a button for Z-Wave™ inclusion/exclusion and an LED for various status indications. The functionality of the SIG1 and SIG2 inputs is: +- Analog Triggering: Various trigger conditions can be set for high-to-low and low-to-high transitions. This provides great flexibility for capturing digital or analog events in a wide variety of applications. The trigger status can be automatically sent to the controller. +- Associations: Each input can be associated with up to two other Z-Wave™ devices, so that, for example, an associated device will automatically turn on (or off) based on the occurrence of a trigger event. +Voltage Reporting: The analog input voltage levels can also be sent to the controller. +The physical outputs are relays that are typically activated by Z-Wave™ commands. However, the user can override Z-Wave™ control by configuring the input trigger conditions to be mapped to the output relays via logical AND/OR functions. + + MIMO2+ + U.S. / Canada / Mexico + 1) Activate exclusion mode on your Z-wave controller. +2) Press the program button once. +3) LED will blink 4 times quickly to indicate "in network" status. + 1) Activate inclusion mode on your Z-wave controller. +2) Press the program button once. +3) LED will blink 2 times quickly to indicate "in network" status. + MIMO2+ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1893/MIMO2 Plus Manual and Tech Appendix 2016-07-29.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1893/xml + + + + + + + + 0 The relay will remain latched in the position it is commanded to (open/off or closed/on). + -128 to 127 Set this value to the amount of time in 100ms increments for the relay to remain closed/on before automatically returning to the open/off state. For example, a value of 2 = 0.2 Seconds. + + + + + 0 The relay will remain latched in the position it is commanded to (open/off or closed/on). + -128 to 127 Set this value to the amount of time in 100ms increments for the relay to remain closed/on before automatically returning to the open/off state. For example, a value of 2 = 0.2 Seconds. + + + + Set this value to trigger between thresholds. + + + Set this value to set the lower threshold high number + + + Set this to set the lower threshold low number. + + + Set this to set the upper threshold, high number + + + Set this to set the upper threshold low number + + + Set this value to trigger between thresholds. + + + Set this value to set the lower threshold high number + + + Set this to set the lower threshold low number. + + + Set this to set the upper threshold, high number + + + Set this to set the upper threshold low number + + + + + + + + + + + diff --git a/openzwave/fortrezz/mimolite.xml b/openzwave/fortrezz/mimolite.xml new file mode 100644 index 00000000..79c319cd --- /dev/null +++ b/openzwave/fortrezz/mimolite.xml @@ -0,0 +1,105 @@ + + + http://www.openzwave.com/device-database/0084:0111:0453 + images/fortrezz/mimolite.png + https://products.z-wavealliance.org/products/1756/ + U.S. / Canada / Mexico + MIMOlite + MIMOlite + Make virtually anything speak Z-wave™! The MiMOlite Module is an interface / bridge module, capable of converting a wire or wireless input to a wire or wireless output. It provides one relay to wirelessly control low voltage applications & one signal input to connect a digital, analog, or pulse signal into your Z-waveTM network. + +Common Applications + + Garage Doors & Motorized Gates + Wired Door Bells / Chimes + Control Solenoids + Connect to existing wired buttons + Security Panel Zone-in + Motorized Shades + Connect to various wired sensors including Temperature probes, Soil Moisture probes, Float switches, Level Sensors, Reed Switches, Door / Window sensors, etc. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1756/xml + + + + + + + Clear Pulse Meter Counts (actual value is dont care; count gets reset whenever + this command is received regardless of value). This parameter is for SIG1 only. + + + + + SIG1 triggered/untriggered sets or clears Relay1. + Refer to description in User Manual under section, Input to Relay Mapping. Note + that neither a Basic Report nor a Binary Switch Report is sent when relay is + automatically set or cleared by Trigger Mapping. Only applies to the Relay1 output. + + + + + SIG1 high lower threshold. + Must be less than Upper Threshold Low and greater than Lower Threshold Low. + + + + + SIG1 low lower threshold. + + + + + SIG1 high upper threshold. + + + + + SIG1 low upper threshold. + Must be greater than Lower Threshold High and less than Upper Threshold High. + + + + + Bits 7 - 2 are ignored and should be set to 0 + + Bit1 : Digital-Configuration flag + 1=Set Trigger levels for this channel to digital thresholds (approx. 1V); Default + 0=Set Trigger levels to analog thresholds (see parameters 4 through 7) + + Bit0 : Trigger-Between-Thresholds flag (see below) + 1 = Set to triggered when input falls between thresholds; Default + 0 = Set to triggered when input falls outside of thresholds + + + + + + + + + Periodic send interval of Multilevel Sensor Reports (Association Group 2) and/or + Pulse Count Reports (Association Group 5) for SIG1. This parameter has a resolution + of 10 seconds; for example, 1 = 10 seconds, 2 = 20 seconds, 3 = 30 seconds (Default), + ... 255 = 2550 seconds = 42.5 minutes. A value of 0 disables automatic reporting. + + + + + Momentary Relay1 output enable/disable. + 1..255 = enable / value sets the approximate momentary on time in increments + of 100msec. + + + + + + + + + + + + + + diff --git a/openzwave/fortrezz/ssa2.xml b/openzwave/fortrezz/ssa2.xml new file mode 100644 index 00000000..dab5ba76 --- /dev/null +++ b/openzwave/fortrezz/ssa2.xml @@ -0,0 +1,43 @@ + + + http://www.openzwave.com/device-database/0084:0107:0313 + images/fortrezz/ssa2.png + https://products.z-wavealliance.org/products/130/ + http://www.fortrezz.com/ + FortrezZ SSA1/SSA2 Siren & Strobe Alarm + U.S. / Canada / Mexico + The SSA1 / SSA2 is a Z-Wave enabled device that will sound a loud siren and/or flash a strobe light when signaled via a Z-Wave enabled network. SSA1: clear lens version; SSA2: red lens version.Integrate it into the home automation and/ or security network, and this siren/strobe module will deliver the audible and visual notifications you can depend on. +- SSA will sound a loud audible alarm >110dB@1m and a strobe lighting when an alarm signal is received from a device in the Z-Wave home network. +- Intended for use inside a Z-Wave Home Automation network as a Siren / Strobe Light Alarm. + +- Can be used in a normal, existing home’s security system with wired controllers, using Z-Wave to RS-232/485 bridge. + +- Extends the range of existing Z-Wave devices in the mesh network by acting as a signal repeater. + +- Uses the latest and most successful wireless home automation technology. + +- Tamper proof. Uses 9V batter backup to sound alarm if AC power is disconnected / cut. +- SSA is fully programmable with Z-wave smart controllers to provide the audible and visual notifications you set for your automation and/or security network. + + - Siren ONLY mode + + - Strobe ONLY mode + + - Strobe & Siren Mode + SSA1 - SSA2 01 + http://www.fortrezz.com/ + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/130/xml + + + + + + + Delay, from the time the siren-strobe turns on, before the Basic Set Off command is accepted. + This could be used, for example, to avoid the situation where an associated window/door sensor turns the SSA1 alarm on and then immediately off when the window/door is opened and then quickly closed. + -128 seconds to -1 seconds -> Interpreted as unsigned integer for negative values sent in set command. + + + + diff --git a/openzwave/fortrezz/ssa3.xml b/openzwave/fortrezz/ssa3.xml new file mode 100644 index 00000000..5e33a702 --- /dev/null +++ b/openzwave/fortrezz/ssa3.xml @@ -0,0 +1,35 @@ + + + http://www.openzwave.com/device-database/0084:0205:0343 + images/fortrezz/ssa3.png + https://products.z-wavealliance.org/products/931/ + U.S. / Canada / Mexico + http://fortrezz.com/index.php/products/siren/itemlist/category/18-siren-strobe-alarm-wire-wireless + Siren & Strobe Alarm + SSA3-P4 + Siren Strobe Alarm SSA3 by FortrezZ, is a professional grade, with both wire and wireless triggers to be used as an alarm device for home security or home automation. + +SSA3 can be connected and triggered the traditional way, by wire, from the home security panel, or by wire from the security loop and also to be used wireless on the Z-Wave network. SSA3 can be used indoor and/or outdoors and will sound a loud siren and flash a strobe light when an alarm message or alert is received on the Z-Wave network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/931/xml + + + + + + + Delay, from the time the siren-strobe turns on, before the Basic Set Off command is accepted; + 1 Byte (in seconds, default is 0, interpreted as unsigned integer for negative values sent in set command). + This could be used, for example, to avoid the situation where an associated window/door sensor turns the SSA3 alarm on and immediately off when the window/door is opened and then quickly closed + + + + + + + + + + + + diff --git a/openzwave/fortrezz/wv01.xml b/openzwave/fortrezz/wv01.xml new file mode 100644 index 00000000..32067620 --- /dev/null +++ b/openzwave/fortrezz/wv01.xml @@ -0,0 +1,32 @@ + + + http://www.openzwave.com/device-database/0084:020C:0213 + images/fortrezz/wv01.png + https://products.z-wavealliance.org/products/178/ + WV-01_1002 + Professional grade, electrically operated water shutoff valve that is Z-Wave Wireless compatible + FortrezZ Wireless Water Valve + U.S. / Canada / Mexico + http://www.fortrezz.com/wv01.html + http://www.fortrezz.com/ + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/178/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/817/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/818/xml + + https://products.z-wavealliance.org/products/818/ + U.S. / Canada / Mexico + Wireless Water Valve + + + + + + + + + + + + + diff --git a/openzwave/fortrezz/wwa-01aa.xml b/openzwave/fortrezz/wwa-01aa.xml new file mode 100644 index 00000000..7f7d6b55 --- /dev/null +++ b/openzwave/fortrezz/wwa-01aa.xml @@ -0,0 +1,19 @@ + + + http://www.openzwave.com/device-database/0084:0210:0013 + images/fortrezz/wwa-01aa.png + https://products.z-wavealliance.org/products/302/ + http://www.fortrezz.com/ + Wireless Water & Freeze Alarm. Wireless Water Alarm WWA-01AA. This product will provide you with peace of mind and the protection you expect. Water damages are caused by leaking pipes, corroded water heaters, water storage tanks, fixtures in bathrooms, laundry rooms, refrigerator drip pans etc. + +•Wireless Water Alarm WWA-01AA is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Inclusion of this WWA-01 into a Z-WaveTM network allows remote status monitoring and alerts when the detector is triggered. Other Z-Wave nodes in the system also act as repeaters if they support that function. + WWA-01AA - Wireless Water & Freeze Alarm + U.S. / Canada / Mexico + http://www.fortrezz.com/ + WWA-01AA + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/302/xml + + + + diff --git a/openzwave/fortrezz/wwa02.xml b/openzwave/fortrezz/wwa02.xml new file mode 100644 index 00000000..b29e886c --- /dev/null +++ b/openzwave/fortrezz/wwa02.xml @@ -0,0 +1,39 @@ + + + http://www.openzwave.com/device-database/0084:0109:0023 + images/fortrezz/wwa02.png + https://products.z-wavealliance.org/products/91/ + http://www.fortrezz.com/ + http://www.fortrezz.com/ + WWA-02 - Wireless Water & Temperature Alarm + Wireless Water Alarm WWA-02AA. This product will provide you with peace of mind and the protection you expect. Water damages are caused by leaking pipes, corroded water heaters, water storage tanks, fixtures in bathrooms, laundry rooms, refrigerator drip pans etc. + +•Wireless Water Alarm WWA-02AA is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Inclusion of this WWA-02AA into a Z-WaveTM network allows remote status monitoring and alerts when the detector is triggered. Other Z-Wave nodes in the system also act as repeaters if they support that function. + WWA-02 + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/91/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/92/xml + + https://products.z-wavealliance.org/products/92/ + CEPT (Europe) + WWA-02 + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/frostdale/fdn2311.xml b/openzwave/frostdale/fdn2311.xml new file mode 100644 index 00000000..49e863ac --- /dev/null +++ b/openzwave/frostdale/fdn2311.xml @@ -0,0 +1,17 @@ + + + http://www.openzwave.com/device-database/0110:0001:2411 + images/frostdale/fdn2311.png + https://products.z-wavealliance.org/products/599/ + http://www.frostdale.com/products/switch_2-4_buttons.html + FDN2311 + The nanogrid™ three button switch provides complete control over three independent light fixtures, with a maximum load rating of 600 watts. No additional wiring or configuration is needed to replace existing switches, and it is easily included in a Z-Wave network. Built-in temperature sensors can deliver room temperature to a Z-Wave gateway or thermostat, and may be used to trigger climate control events. The ESM (Energy Saving Mode) feature is activated by pressing and holding the switch’s top button and helps to reduce electricity usage. The switch’s unique design is available in five elegant finishes, with LEDs available in white, blue, or green. + http://www.frostdale.com/faq.html + nanogrid™ Wireless Light Switch + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/599/xml + + + + diff --git a/openzwave/frostdale/fdn2nxx.xml b/openzwave/frostdale/fdn2nxx.xml new file mode 100644 index 00000000..00c9861a --- /dev/null +++ b/openzwave/frostdale/fdn2nxx.xml @@ -0,0 +1,9 @@ + + + + + + 4 + + + diff --git a/openzwave/ge/12719-plugin-switch.xml b/openzwave/ge/12719-plugin-switch.xml new file mode 100644 index 00000000..7c2e2282 --- /dev/null +++ b/openzwave/ge/12719-plugin-switch.xml @@ -0,0 +1,25 @@ + + + http://www.openzwave.com/device-database/0063:3031:5052 + images/ge/12719-plugin-switch.png + https://products.z-wavealliance.org/products/1210/ + 45703 + U.S. / Canada / Mexico + http://www.ezzwave.com + Jasco Lighting and Small Appliance Module (45703) + Florescent Light and Appliance Module + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1193/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1210/xml + + + + + + + + + diff --git a/openzwave/ge/12720.xml b/openzwave/ge/12720.xml new file mode 100644 index 00000000..b47200a2 --- /dev/null +++ b/openzwave/ge/12720.xml @@ -0,0 +1,22 @@ + + + http://www.openzwave.com/device-database/0063:3130:6363 + images/ge/14284.png + https://products.z-wavealliance.org/products/1194/ + 1. If plugged in, unplug the Switch from the receptacle. +2. Press and hold the top button for at least 3 seconds while you plug the switch into a receptacle. + 12720/ZW4201 + http://z-wave-assets.s3-us-west-2.amazonaws.com/docs/138/B0013V8K3O_GE_Jasco_Z-Wave_Plug-in_Outdoor_Smart_Switch_12720_Manual.pdf + Transform any home into a smart home with the GE Z-Wave Outdoor Smart Switch. The lighting control enables wireless control of on/off functions for outdoor applications, and is compatible with incandescent, LED, Xenon, Halogen, fluorescent and compact fluorescent bulbs. The weather-resistant housing with a protective outlet cover safeguards the outlet from dirt and debris when not in use. The discreet black color blends in with any outdoor environment. Perfect for decorative or seasonal lighting, fountains and other outdoor plug-in appliances. Take control of your home lighting with GE Z-Wave Smart Lighting Controls! + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press and release the manual/program button on the smart switch to exclude it from the network. + Plug-in Outdoor Smart Switch + U.S. / Canada / Mexico + 1. Follow the instructions for you Z-Wave certified controller to include the smart switch to the Z-Wave network. +2. Once the controller is ready to include your outdoor smart switch, press and release the manual/program button on the smart switch to include it in the network. +3. Once your controller has confirmed that the smart switch has been included, refresh the Z-Wave network to optimize performance. + + Initial Metadata added - https://products.z-wavealliance.org/products/1194/xml + + + diff --git a/openzwave/ge/12724-dimmer.xml b/openzwave/ge/12724-dimmer.xml new file mode 100644 index 00000000..a27fee4b --- /dev/null +++ b/openzwave/ge/12724-dimmer.xml @@ -0,0 +1,80 @@ + + + http://www.openzwave.com/device-database/0063:3031:4944 + images/ge/12724-dimmer.png + https://products.z-wavealliance.org/products/1197/ + Transform any home into a smart home with the GE Z-Wave Smart Fan Control. The in-wall fan control easily replaces any standard in-wall switch remotely controls a ceiling fan in your home and features a three-speed control system. Your home will be equipped with ultimate flexibility with the GE Z-Wave Smart Fan Control, capable of being used by itself or with up to four GE add-on switches. Screw terminal installation provides improved space efficiency when replacing existing switches and the integrated LED indicator light allows you to easily locate the switch in a dark room. The GE Z-Wave Smart Fan Control is compatible with any Z-Wave certified gateway, providing access to many popular home automation systems. Take control of your home lighting with GE Z-Wave Smart Lighting Controls! + U.S. / Canada / Mexico + In-Wall Smart Fan Control + http://www.ezzwave.com + 12724 / ZW3005 + https://products.z-wavealliance.org/products/1198/ + U.S. / Canada / Mexico + 12725 / ZW3006 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1197/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1201/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1202/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1221/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2103/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2506/xml + Update for 3032 + Add Verifed Change Flag + + https://products.z-wavealliance.org/products/1201/ + U.S. / Canada / Mexico + 12729 / ZW3004 + https://products.z-wavealliance.org/products/1221/ + U.S. / Canada / Mexico + 45743 + https://products.z-wavealliance.org/products/2506/ + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2506/Binder2.pdf + 14287/ZW4002 + 1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network. +2. Once the controller is ready to include your device, press and release the top or bottom of the smart fan control switch (rocker) to include it in the network. +3. Once your controller has confirmed the device has been included, refresh the Z-Wave network to optimize performance. + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press and release the top or bottom of the wireless smart switch (rocker) to exclude it from the network. + 1. Quickly press ON (Top) button three (3) times then immediately press the OFF (Bottom) button three (3) times. The LED will flash ON/OFF 5 times when completed successfully. +Note: This should only be used in the event your network’s primary controller is missing or otherwise inoperable. + + + + + Sets when the LED on the switch is lit. + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + + + true + + + diff --git a/openzwave/ge/12727.xml b/openzwave/ge/12727.xml new file mode 100644 index 00000000..913f3adf --- /dev/null +++ b/openzwave/ge/12727.xml @@ -0,0 +1,18 @@ + + + http://www.openzwave.com/device-database/0063:3033:4952 + images/ge/12727.png + https://products.z-wavealliance.org/products/1200/ + U.S. / Canada / Mexico + "Transform any home into a smart home with the GE Z-Wave Smart Lighting Control Smart Toggle Switch. The in-wall GE Z-Wave Smart Lighting Control Toggle Switch replaces your current switch, uses existing wiring and remotely controls the On/Off functions of your permanently installed lighting and ceiling fans. The toggle switch can be used in groups of multiple lights or turned on and off within ambient interior lighting scenes and and provides your home with ultimate flexibility, capable of being used by itself or with up to four GE add-on switching in three, four, five and six-way wiring configurations. Three-way wiring configuration turns the light or appliance on/off from two separate locations. Four-way wiring configuration turns the light or appliance on/off from three separate locations. The GE Z-Wave Smart Lighting Control Toggle Switch is compatible with any Z-Wave certified gateway, providing access to many popular home automation systems and application. Take control of your home lighting with GE Z-Wave Smart Lighting Controls! + +Z-Wave is the world’s largest ecosystem of interoperable smart home products. Z-Wave lighting controls provide an easy-to-install and affordable system to control lighting and small appliances in your home. Add GE Z-Wave lighting controls to a Z-Wave certified gateway to access and control your home from anywhere in the world using your smartphone, tablet or computer as a home automation command center. Never worry if you accidentally left the lights on because you can turn them off remotely or program your lights to go on/off at specific times. Create customized lighting scenes for any occasion such as a “go to sleep” scene or a “movie night” scene. Give the illusion that someone is home by programming the lights to turn on/off while you are away—perfect for deterring crime and adding additional security!" + + GE Z-Wave In-Wall Smart Switch (Toggle) + 12727 / ZW4003 + http://www.ezzwave.com + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1200/xml + + + diff --git a/openzwave/ge/14280-plugin-dimmer.xml b/openzwave/ge/14280-plugin-dimmer.xml new file mode 100644 index 00000000..b8407476 --- /dev/null +++ b/openzwave/ge/14280-plugin-dimmer.xml @@ -0,0 +1,58 @@ + + + none + images/ge/14280-plugin-dimmer.png + https://products.z-wavealliance.org/products/2139/ + Plug-in Smart Dimmer, Dual Plug With Simultaneous Control + https://products.z-wavealliance.org/ProductManual/File?folder=%26filename=MarketCertificationFiles/2139/Binder1.pdf + U.S. / Canada / Mexico + + + + 14280/ZW3107 + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2139/xml + + + + + Sets when the LED on the switch is lit. + + + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + + + true + + + + + + + + + + + diff --git a/openzwave/ge/14282-plugin-switch.xml b/openzwave/ge/14282-plugin-switch.xml new file mode 100644 index 00000000..0306623d --- /dev/null +++ b/openzwave/ge/14282-plugin-switch.xml @@ -0,0 +1,62 @@ + + + http://www.openzwave.com/device-database/0063:3033:5052 + images/ge/14282-plugin-switch.png + https://products.z-wavealliance.org/products/2525/ + Adding your device to a Z-Wave network: +1. Follow the instructions for your Z-Wave certified controller to +include the device to the Z-Wave network. +2. Once the controller is ready to include your smart switch, +single press and release the manual/program button on the +smart switch to include it in the network. +Now you have complete control to turn your lamp ON/OFF +according to groups, scenes, schedules and interactive +automations programmed by your controller. +If your Z-Wave certified controller features Remote Access, +you can now control your lighting from your mobile devices + To exclude and reset the device: +1. Follow the instructions for your Z-Wave certified controller to +exclude a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press +and release the manual/program button on the smart switch +to exclude it from the network. + Transform any home into a smart home with the GE Z-Wave Smart Lighting Control and Appliance Module. The lighting control enables wireless control of on/off functions for standard table and floor lamps, and is compatible with incandescent, LED, Xenon, Halogen, fluorescent and compact fluorescent bulbs. Easily controlled by your mobile device or computer using any Z-Wave certified gateway, the space-saving horizontal module plugs into a standard wall receptacle without blocking the second outlet or obstructing placement of furniture. It provides dual simultaneous Z-Wave enabled outlets for the lamp or appliance that you would like to control and a regular pass-through AC outlet for other electrical appliances. Perfect for plug-in fans, heaters, lamps and more! Take control of your home lighting with GE Z-Wave Smart Lighting Controls! + To return your switch to factory defaults: +1. If plugged in, unplug the Switch from the receptacle. +2. Press and hold the top button for at least 3 seconds while +you plug the switch into a receptacle. +Note: This should only be used in the event your networks’ +primary controller is missing or otherwise inoperable. + 14282/ZW4106 + Plug-in Smart Switch, Dual Plug + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2525/Binder1.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1437/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2104/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2525/xml + + + + + + When shipped from the factory, the LED is set to turn ON when the connected light is turned OFF. + This is the default setting and can be changed if your primary controller supports the node configuration function. + To make the LED turn ON when the light is turned ON, change parameter 3s value to 1. + To turn the LED OFF at all times, change parameter 3s value to 2. + + + + + + + + + + + + + diff --git a/openzwave/ge/14284.xml b/openzwave/ge/14284.xml new file mode 100644 index 00000000..f16fd454 --- /dev/null +++ b/openzwave/ge/14284.xml @@ -0,0 +1,23 @@ + + + http://www.openzwave.com/device-database/0063:3032:4F50 + images/ge/14284.png + https://products.z-wavealliance.org/products/2526/ + 1. If plugged in, unplug the Switch from the receptacle. +2. Press and hold the top button for at least 3 seconds while you plug the switch into a receptacle. + 14284/ZW4201 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2526/14284 EnFrSp QSG v1.pdf + Transform any home into a smart home with the GE Z-Wave Outdoor Smart Switch. The lighting control enables wireless control of on/off functions for outdoor applications, and is compatible with incandescent, LED, Xenon, Halogen, fluorescent and compact fluorescent bulbs. The weather-resistant housing with a protective outlet cover safeguards the outlet from dirt and debris when not in use. The discreet black color blends in with any outdoor environment. Perfect for decorative or seasonal lighting, fountains and other outdoor plug-in appliances. Take control of your home lighting with GE Z-Wave Smart Lighting Controls! + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press and release the manual/program button on the smart switch to exclude it from the network. + Plug-in Outdoor Smart Switch + U.S. / Canada / Mexico + 1. Follow the instructions for you Z-Wave certified controller to include the smart switch to the Z-Wave network. +2. Once the controller is ready to include your outdoor smart switch, press and release the manual/program button on the smart switch to include it in the network. +3. Once your controller has confirmed that the smart switch has been included, refresh the Z-Wave network to optimize performance. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1853/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2526/xml + + + diff --git a/openzwave/ge/14285.xml b/openzwave/ge/14285.xml new file mode 100644 index 00000000..b923bae7 --- /dev/null +++ b/openzwave/ge/14285.xml @@ -0,0 +1,58 @@ + + + http://www.openzwave.com/device-database/0063:3032:4F44 + images/ge/14285.png + https://products.z-wavealliance.org/products/2939/ + 1. Place the device into ON mode (upper position of Operating Mode Switch) +2. Press and hold the programming button. +3. While holding programming button, place device into OFF mode (middle position of Operating Mode Switch). +4. While holding programming button, place device back into ON mode (upper position of Operating Mode Switch). +5. After three (3) seconds, release programming button. Green LED will flash 3 times when completed successfully. + +Note: This should only be used in the event your networks primary controller is missing or otherwise inoperable. + 14285/ZW4007 + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2939/14285%20QSG.pdf + Transform any home into a smart home with the GE 40 Amp Z-Wave Direct-Wire Indoor/Outdoor Smart Switch. When added to a Z-Wave network, the heavy duty switch enables wireless control of on/off functions for large load, hard-wired applications such as waters heaters, landscape lighting, spas, pool pumps and heaters. The Smart Switch can be used indoors or outdoors and features an easy access wire connection block, front mounted LED lights indicating power and on/off status, and an override switch to turn connected devices on or off manually. The Smart Switch is housed in a lockable, tamper-resistant case to ensure settings and wiring are secure. The rugged, weather-resistant design will keep out dirt and debris while being suitable for use in extreme weather conditions. The GE Z-Wave Direct-Wire Outdoor Smart Switch is also equipped with state-of-the-art energy monitoring capability, allowing you to monitor watts and kilowatt hours, helping you keep your energy costs to a minimum. Take control of your home lighting and large load devices with GE Z-Wave Smart Lighting Controls! + Direct-Wire Outdoor Smart Switch + U.S. / Canada / Mexico + 1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network. +2. Once the controller is ready to add your device, press and release the programming button to add it to the network. If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the back of the box, or the QR code label on the product. +3. Once your controller has confirmed that the device has been added, refresh the Z-Wave network to optimize performance. + 1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network. +2. Once the controller is ready to remove your device press and release the programming button to remove it from the network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2939/xml + + + + + + Product State after Power Reset + + + + + + Energy Report Mode + + + + + + Energy Report Frequency + + + Alternate Exclusion + + + + + + + + + + + + + diff --git a/openzwave/ge/14288-outlet.xml b/openzwave/ge/14288-outlet.xml new file mode 100644 index 00000000..f87f5b69 --- /dev/null +++ b/openzwave/ge/14288-outlet.xml @@ -0,0 +1,50 @@ + + + http://www.openzwave.com/device-database/0063:3134:4952 + images/ge/14288-outlet.png + https://products.z-wavealliance.org/products/2372/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2372/14315 QSG v0.pdf + In-Wall Tamper Resistant Smart Outlet + U.S. / Canada / Mexico + 14315/ZW1002 + 1. Follow the instructions for your Z-Wave certified controller to +remove a device from the Z-Wave network. +2. Once the controller is ready to remove your device, press and +release the manual/program button to remove it from the +network. + Follow the instructions for your Z-Wave certified +controller to add a device to the Z-Wave network. +2. Once the controller is ready to add your device, press and +release the Program Button to add it in the network. + Press the button 3 times, then press and hold the button for at least 3 +seconds. The LED will blink 5 times to confirm. +NOTE: This should only be used in the event your network’s primary +controller is missing or otherwise inoperable + Transform any home into a smart home with the Jasco Z-Wave Tamper Resistant Smart Outlet. The Jasco Z-Wave Tamper Resistant Smart Outlet enables wireless control of on/off functions from the Z-Wave controlled outlet, and is compatible with incandescent, LED, Xenon, Halogen, fluorescent and compact fluorescent bulbs. The tamper resistant duplex receptacle includes a blue LED indicator light to easily locate the receptacle in a dark room. The receptacle replaces your current electrical outlet, uses your existing wiring and provides a Z-Wave enabled outlet for the lamp or appliance that you would like to control and a standard pass-through AC outlet for other electrical appliances. Take control of your home lighting with Jasco Z-Wave Smart Lighting Controls! + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2236/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2372/xml + + + + + + Sets when the LED on the outlet is lit. + + + + + + + + + + + + + + diff --git a/openzwave/ge/14291-switch.xml b/openzwave/ge/14291-switch.xml new file mode 100644 index 00000000..21e73042 --- /dev/null +++ b/openzwave/ge/14291-switch.xml @@ -0,0 +1,45 @@ + + + http://www.openzwave.com/device-database/0063:3036:4952 + images/ge/14291-switch.png + https://products.z-wavealliance.org/products/2501/ + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to exclude your device, press and release the top button of the wireless smart switch (rocker) to exclude it from the network. + 14291/ZW4005 + Transform any home into a smart home with the GE Z-Wave In-Wall Smart Switch. The on/off switch replaces your current light switch, uses your existing wiring, and provides Z-Wave wireless and in-wall control of overhead lighting. The switch enables wireless control of on/off functions of direct wire incandescent, LED, xenon, halogen and fluorescent lighting. Providing ultimate flexibility, the GE Z-Wave Smart Lighting Control On/Off Switch allows you to operate the switch by itself or easily integrate the switch with two-way, three-way or four-way wiring configurations by adding the GE Add-On switch. Single pole wiring configuration turns the light or appliance on/off from one location. Three-way wiring configuration turns the light on/off from two separate locations. Four-way wiring configuration turns the light on/off from three separate locations. The GE Add-On Switch is required for Three-way or Four-way installations. The lighting control includes a blue LED indicator light to easily locate the switch in a dark room. Take control of your home lighting with GE Z-Wave Smart Lighting Controls! + 1. Quickly press ON (Top) button 3 times then immediately press the OFF (Bottom) button 3 times. The LED will flash ON/OFF 5 times when completed successfully. +2. Please use this reset procedure only when the primary controller is missing or inoperable. + U.S. / Canada / Mexico + In-Wall Smart Switch + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2501/Binder1.pdf + 1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network. +2. Once the controller is ready to include your device, press and release the top or bottom of the wireless smart switch(rocker) to include it in the network. +3. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1438/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1879/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2501/xml + + + + + Sets when the LED on the switch is lit. + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + + + + + + + + diff --git a/openzwave/ge/14292-toggle-switch.xml b/openzwave/ge/14292-toggle-switch.xml new file mode 100644 index 00000000..ee86bde3 --- /dev/null +++ b/openzwave/ge/14292-toggle-switch.xml @@ -0,0 +1,42 @@ + + + http://www.openzwave.com/device-database/0063:3037:4952 + images/ge/14292-toggle-switch.png + https://products.z-wavealliance.org/products/2502/ + 1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network. +2. Once the controller is ready to include your device, press up and release on the toggle to include it in the network. +3. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. + 14292/ZW4003 + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to exclude your device, press up and release on the toggle to exclude it from the network. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2502/Binder2.pdf + Transform any home into a smart home with the GE Z-Wave Smart Toggle Switch. The In-Wall Smart Toggle Switch can easily replaces any standard in-wall switch and remotely controls a light in your home. Your home will be equipped with ultimate flexibility with the GE Z-Wave Smart Toggle Switch, capable of being used by itself or with up to four add-on switches. Screw terminal installation provides improved space efficiency when replacing existing switches and the integrated LED indicator light allows you to easily locate the switch in a dark room. The GE Z-Wave In-Wall Smart Toggle Switch is compatible with any Z-Wave certified gateway, providing access to many popular home automation systems. Take control of your home lighting with GE Z-Wave Smart Lighting Controls! + In-Wall Smart Toggle Switch (White) + U.S. / Canada / Mexico + 1. Quickly press ON (up) 3 times then immediately press the OFF (Down) button 3 times. Note: This should only be used in the event your networks primary controller is missing or otherwise inoperable. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1856/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2055/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2502/xml + + https://products.z-wavealliance.org/products/2055/ + U.S. / Canada / Mexico + 14293/ZW4003 + + + + + Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + + + + + + + + diff --git a/openzwave/ge/14294-dimmer.xml b/openzwave/ge/14294-dimmer.xml new file mode 100644 index 00000000..285680b7 --- /dev/null +++ b/openzwave/ge/14294-dimmer.xml @@ -0,0 +1,97 @@ + + + + http://www.openzwave.com/device-database/0063:3038:4944 + images/ge/14294-dimmer.png + https://products.z-wavealliance.org/products/2105/ + In-Wall Smart 1000W Dimmer + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2105/Binder1.pdf + U.S. / Canada / Mexico + Quickly press ON (Top) button three (3) times then immediately +press the OFF (Bottom) button three (3) times. The LED will flash +ON/OFF 5 times when completed successfully. +NOTE: This should only be used in the event your network’s +primary controller is missing or otherwise inoperable. + 1. Follow the instructions for your Z-Wave certified controller to +include a device to the Z-Wave network. +2. Once the controller is ready to add your device, +press and release the top or bottom of the wireless smart +switch (rocker) to add it in the network. +Please reference the controller’s manual for instructions. + Transform any home into a smart home with the GE Z-Wave Smart 1000W Dimmer. The In-Wall Smart 1000W Dimmer can easily replace any standard in-wall switch and remotely controls a light in your home. Your home will be equipped with ultimate flexibility with the GE Z-Wave Smart 1000W Dimmer, capable of being used by itself or with up to four add-on switches. Screw terminal installation provides improved space efficiency when replacing existing switches and the integrated LED indicator light allows you to easily locate the switch in a dark room. The GE Z-Wave In-Wall Smart 1000W Dimmer is compatible with any Z-Wave certified gateway, providing access to many popular home automation systems. Take control of your home lighting with GE Z-Wave Smart Lighting Controls! + +Z-Wave is the world’s largest ecosystem of inter operable smart home products. Z-Wave lighting controls provide an easy-to-install and affordable system to control lighting and small appliances in your home. Add GE Z-Wave lighting controls to a Z-Wave certified gateway to access and control your home from anywhere in the world using your smartphone, tablet or computer as a home automation command center. Never worry if you accidentally left the lights on because you can turn them off remotely or program your lights to go on/off at specific times. Create customized lighting scenes for any occasion such as a “go to sleep” scene or a “movie night” scene. Give the illusion that someone is home by programming the lights to turn on/off while you are away—perfect for deterring crime and adding additional security!" + 14294/ZW3005 + 1. Follow the instructions for your Z-Wave certified controller to +remove a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press +and release the top or bottom of the wireless smart dimmer +(rocker) to remove it from the network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1442/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2105/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2168/xml + Add Verified Change Flag + Fixed metadata, added undocumented configuration parameters + + + + + + Sets when the LED on the switch is lit. + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + Adjust the speed at which the light ramps to a specific value other than 0 and FF. + + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Turn your dimmer into an On/Off switch with switch mode. + + + + + Set the minimum dimmer threshold when manually or remotely controlled. + + + + + true + + + + + + + + + + + diff --git a/openzwave/ge/14295-dimmer-toggle.xml b/openzwave/ge/14295-dimmer-toggle.xml new file mode 100644 index 00000000..fd6a070e --- /dev/null +++ b/openzwave/ge/14295-dimmer-toggle.xml @@ -0,0 +1,62 @@ + + + http://www.openzwave.com/device-database/0063:3130:4944 + images/ge/14295-dimmer-toggle.png + https://products.z-wavealliance.org/products/2048/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2048/14295 QSG v0.pdf + In-Wall Smart Toggle Dimmer + 1. Follow the instructions for your Z-Wave certified controller to +include a device to the Z-Wave network. +2. Once the controller is ready to include your device, press +and release the top or bottom of the wireless smart dimmer +(rocker) to include it in the network. + U.S. / Canada / Mexico + 14295/ZW3004 + 1. Quickly press ON (up) button (3) times then immediately press the OFF (down) button (3) times. +Note: This should only be used in the even your network's primary controller is missing or otherwise inoperable. + 1. Follow the instructions for your Z-Wave certified controller to +exclude a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press +and release the top or bottom of the wireless smart dimmer +(rocker) to exclude it from the network. + Transform any home into a smart home with the GE Z-Wave In-Wall Smart Toggle Dimmer. The dimmer enables wireless control of on/off and dim functions of hard-wired dimmable LED/CFL and incandescent lighting. The dimmer replaces your current light switch, uses your existing wiring, and provides Z-Wave wireless and in-wall control of overhead lighting. Use the dimmer feature to customize the lighting output and create the perfect ambiance for any room. Providing ultimate flexibility, the In-Wall Smart Dimmer allows you to operate the switch by itself or easily integrate the switch three-way or four-way wiring configurations by adding the GE Add-On Switch. Single Pole wiring configuration controls the light from one location. Three-way wiring configuration controls the light from two separate locations. Four-way wiring configuration controls the light from three separate locations. The GE Add-On Switch is required for three-way or four-way installations. Take control of your home lighting with GE Z-Wave Wireless Lighting Controls! + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2048/xml + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + + + + + + + + + diff --git a/openzwave/ge/14298.xml b/openzwave/ge/14298.xml new file mode 100644 index 00000000..3cdd719e --- /dev/null +++ b/openzwave/ge/14298.xml @@ -0,0 +1,45 @@ + + + http://www.openzwave.com/device-database/0063:3034:4F50 + images/ge/14298.png + https://products.z-wavealliance.org/products/3408/ + 1. If plugged in, unplug the Switch from the receptacle. +2. Press and hold the top button for at least 3 seconds while you plug the switch into a receptacle. + 14298/ZW4202 + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3408/14298%20EnFrSp%20QSG%20v1.pdf + New Plug-in Outdoor Smart Switch is equipt with S2 and Smart Start which allows for easy and secure inclusion. + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press and release the manual/program button on the smart switch to exclude it from the network. + Plug-in Outdoor Smart Switch + U.S. / Canada / Mexico + 1. Follow the instructions for you Z-Wave certified controller to include the smart switch to the Z-Wave network. +2. Once the controller is ready to include your outdoor smart switch, press and release the manual/program button on the smart switch to include it in the network. +3. Once your controller has confirmed that the smart switch has been included, refresh the Z-Wave network to optimize performance. If prompted by the controller to enter the S2 security code +/security number on the side of the box or the QR code label on the product, enter the 5 digit code. + + Initial metadata + + + + + Sets when the LED on the switch is lit. + + + + + + Default - normal exclusion + Active - perform a series of button presses to help eliminate accidental exclusion + + + + + + + + + + + + + diff --git a/openzwave/ge/26931-motion-switch.xml b/openzwave/ge/26931-motion-switch.xml new file mode 100644 index 00000000..5fd6e0cd --- /dev/null +++ b/openzwave/ge/26931-motion-switch.xml @@ -0,0 +1,92 @@ + + + http://www.openzwave.com/device-database/0063:3032:494D + images/ge/26931-motion-switch.png + https://products.z-wavealliance.org/products/2035/ + In-Wall Smart Motion Switch + Press and release the top button ten times. +Note: This should only be used in the event your +network’s primary controller is missing or otherwise +inoperable. + 26931/ZW4006 + U.S. / Canada / Mexico + 1. Follow the instructions for your Z-Wave certified +controller to exclude a device from the Z-Wave +network. +2. Once the controller is ready to exclude your device, +press and release the top or bottom button on the +smart switch to exclude it from the network. + Transform any home into a smart home with the GE In-Wall Smart Motion Switch. This Z-Wave device replaces you current light switch using your existing wiring and provides Z-Wave wireless control of overhead lighting. The switch enables wireless control of On/OFF functions of incandescent, LED, xenon, halogen and fluorescent lighting. Not only does it act as a switch but the GE In-Wall Smart Motion Switch has a built in PIR sensor which can control the local and be set in occupancy or vacancy mode. + 1. Follow the instructions for your Z-Wave certified +controller to include the smart switch to the +Z-Wave network. +2. Once the controller is ready to include your smart +switch, press and release the top or bottom button +on the smart switch to include it in the network. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2035/26931 EnFrSp QSG v1.3 and Parameters.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2035/xml + + + + + + Amount of time the light stays on after motion stops + + + + + + + + + Valid values are 0-99 or 255 for last dimming level + + + Motion-sensing mode of operation. + + + + + + In a three-way configuration, change the top of the add-on switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + + + + + + + + + + + + + 0 = disable + 1 = 10 seconds + 2 = 20 seconds + 3 = 30 seconds + 4 = 45 seconds + ... + 110 = 27 minutes 15 seconds + + + + + + + + + + + + + + + + diff --git a/openzwave/ge/26932-motion-dimmer.xml b/openzwave/ge/26932-motion-dimmer.xml new file mode 100644 index 00000000..8f06af4c --- /dev/null +++ b/openzwave/ge/26932-motion-dimmer.xml @@ -0,0 +1,132 @@ + + + + http://www.openzwave.com/device-database/0063:3033:494d + images/ge/26933-motion-dimmer.png + https://products.z-wavealliance.org/products/2093/ + 26932 + 1. Follow the instructions for your Z-Wave certified +controller to remove a device from the Z-Wave +network. +2. Once the controller is ready to remove your device, +press and release the top button on the smart +dimmer to remove it from the network. + U.S. / Canada / Mexico + Press and release the top button ten times within 5 +seconds. The LED will flash 3 times quickly confirming +change. +Note: This should only be used in the event your +network’s primary controller is missing or otherwise +inoperable + 1. Follow the instructions for your Z-Wave certified +controller to add the smart dimmer to the Z-Wave +network. +2. Once the controller is ready to add your smart +dimmer, press and release the top or bottom +button on the smart dimmer to include it in the +network. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2093/26932 EnFrSp QSG v1.3 and Parameters.pdf + Transform any home into a smart home with the Jasco In-Wall Smart Motion Dimmer. This Z-Wave device replaces you current light switch using your existing wiring and provides Z-Wave wireless control of overhead lighting. The dimmer enables wireless control of On/Off functions of incandescent, LED, xenon, halogen and fluorescent lighting. Not only does it act as a dimmer but the Jasco In-Wall Smart Motion Dimmer has a built in PIR sensor which can control the local load and be set in occupancy or vacancy mode. + + + In-Wall Smart Motion Dimmer + + Initial Metadata Import from ge/26933-motion-dimmer.xml and https://products.z-wavealliance.org/products/2093/xml + Update VerifyChanged flag + + + + + + Amount of time the light stays on after motion stops + + + + + + + + + Valid values are 0-99 or 255 for last dimming level + + + Motion-sensing mode of operation. + + + + + + In a three-way configuration, change the top of the add-on switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + + + + + + + + + + 0 = disable + 1 = 10 seconds + 2 = 20 seconds + 3 = 30 seconds + 4 = 45 seconds + ... + 110 = 27 minutes 15 seconds + + + + + + + + + + + + + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/ge/26933-motion-dimmer.xml b/openzwave/ge/26933-motion-dimmer.xml new file mode 100644 index 00000000..7c1041b2 --- /dev/null +++ b/openzwave/ge/26933-motion-dimmer.xml @@ -0,0 +1,126 @@ + + + http://www.openzwave.com/device-database/0063:3034:494D + images/ge/26933-motion-dimmer.png + https://products.z-wavealliance.org/products/2108/ + 26933 + 1. Follow the instructions for your Z-Wave certified +controller to remove a device from the Z-Wave +network. +2. Once the controller is ready to remove your device, +press and release the top button on the smart +dimmer to remove it from the network. + U.S. / Canada / Mexico + Press and release the top button ten times within 5 +seconds. The LED will flash 3 times quickly confirming +change. +Note: This should only be used in the event your +network’s primary controller is missing or otherwise +inoperable + 1. Follow the instructions for your Z-Wave certified +controller to add the smart dimmer to the Z-Wave +network. +2. Once the controller is ready to add your smart +dimmer, press and release the top or bottom +button on the smart dimmer to include it in the +network. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2108/26933 EnFrSp QSG v1.3 and Parameters.pdf + Transform any home into a smart home with the GE In-Wall Smart Motion Dimmer. This Z-Wave device replaces you current light switch using your existing wiring and provides Z-Wave wireless control of overhead lighting. The dimmer enables wireless control of On/Off functions of incandescent, LED, xenon, halogen and fluorescent lighting. Not only does it act as a dimmer but the GE In-Wall Smart Motion Dimmer has a built in PIR sensor which can control the local load and be set in occupancy or vacancy mode. + + + In-Wall Smart Motion Dimmer + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2108/xml + Fix paraleter size as per https://github.com/OpenZWave/open-zwave/pull/1968 + + + + + + Amount of time the light stays on after motion stops + + + + + + + + + Valid values are 0-99 or 255 for last dimming level + + + Motion-sensing mode of operation. + + + + + + In a three-way configuration, change the top of the add-on switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + + + + + + + + + + 0 = disable + 1 = 10 seconds + 2 = 20 seconds + 3 = 30 seconds + 4 = 45 seconds + ... + 110 = 27 minutes 15 seconds + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/ge/28167-plugin-dimmer.xml b/openzwave/ge/28167-plugin-dimmer.xml new file mode 100644 index 00000000..5af8ac1a --- /dev/null +++ b/openzwave/ge/28167-plugin-dimmer.xml @@ -0,0 +1,92 @@ + + + http://www.openzwave.com/device-database/0063:3038:5044 + images/ge/28167-plugin-dimmer.png + https://products.z-wavealliance.org/products/2100/ + U.S. / Canada / Mexico + Plug-in Smart Dimmer, Single Plug + 1. Follow the instructions for your Z-Wave certified controller to add +the smart dimmer to the Z-Wave network. +2. Once the controller is ready to add your smart dimmer, single +press and release the manual/program button on the smart +dimmer to add it in the network. +Please reference the controller/gateway’s manual for instructions. + 28167/ZW3104 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2100/Binder1.pdf + To return your dimmer to factory defaults: +1. If plugged in, unplug the dimmer from the receptacle. +2. Press and hold the top button for at least 3 seconds while you +plug the dimmer into a receptacle. +Note: This should only be used in the event your networks’ primary +controller is missing or otherwise inoperable. + Transform any home into a smart home with the GE Z-Wave Plug-In Smart Dimmer. The Smart Dimmer enables wireless control of on/off and dim functions for standard incandescent table and floor lamps, as well as dimmable fluorescent, LED and CFL fixtures and more! Use the dimmer control to customize the lighting output and create the perfect ambiance for any room. The space-saving horizontal module plugs into a standard wall receptacle without blocking the second outlet or obstructing placement of furniture. The Dimmer provides one Z-Wave enabled outlet for the lamp you would like to control. Take control of your home lighting with GE Z-Wave Smart Lighting Controls! + 1. Follow the instructions for your Z-Wave certified controller to +remove a device from the Z-Wave network. +2. Once the controller is ready to remove your device, press and +release the manual/program button on the smart dimmer to +remove it from the network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1433/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2100/xml + + + + + + Sets when the LED on the switch is lit. + + + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + + + + + + diff --git a/openzwave/ge/28169-plugin-switch.xml b/openzwave/ge/28169-plugin-switch.xml new file mode 100644 index 00000000..1b9a6e56 --- /dev/null +++ b/openzwave/ge/28169-plugin-switch.xml @@ -0,0 +1,49 @@ + + + http://www.openzwave.com/device-database/0063:3038:5052 + images/ge/28169-plugin-switch.png + https://products.z-wavealliance.org/products/2533/ + Transform any home into a smart home with the GE Z-Wave Smart Lighting Plug-in Smart Switch. The lighting control enables wireless control of on/off functions for standard table and floor lamps, and is compatible with incandescent, LED, Xenon, Halogen, fluorescent and compact fluorescent bulbs. Easily controlled by your mobile device or computer using any Z-Wave certified gateway, the space-saving horizontal module plugs into a standard wall receptacle without blocking the second outlet or obstructing placement of furniture. It provides a Z-Wave enabled outlet for the lamp or appliance that you would like to control. Perfect for plug-in fans, heaters, lamps and more! Take control of your home lighting with GE Z-Wave Smart Lighting Controls! + 1. Follow the instructions for your Z-Wave certified controller to include the device to the Z-Wave network. +2. Once the controller is ready to include your smart switch, single press and release the manual/program button on the smart dimmer to include it in the network. +3. Once your controller has confirmed that the smart switch has been included, refresh the Z-Wave network to optimize performance. + + 1. Follow the instructions for you Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to exclude your device, press and release the manual/program button on the smart switch to exclude it from the network. + + 28169/ZW4103 + 1. If plugged in, unplug the switch from the receptacle. +2. Press and hold the top button for at least 3 seconds while you plug the switch into a receptacle. Note: this should only be used in the event your network’s primary controller is missing or otherwise inoperable. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2533/Binder1.pdf + U.S. / Canada / Mexico + Plug-in Smart Switch (Single Plug) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1435/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1805/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2533/xml + + + + + + When shipped from the factory, the LED is set to turn ON when the connected light is turned OFF. + This is the default setting and can be changed if your primary controller supports the node configuration function. + To make the LED turn ON when the light is turned ON, change parameter 3s value to 1. + To turn the LED OFF at all times, change parameter 3s value to 2. + + + + + + + + + + + + + diff --git a/openzwave/ge/45604.xml b/openzwave/ge/45604.xml new file mode 100644 index 00000000..b756c23a --- /dev/null +++ b/openzwave/ge/45604.xml @@ -0,0 +1,30 @@ + + + http://www.openzwave.com/device-database/0063:3030:5250 + images/ge/45604.png + https://products.z-wavealliance.org/products/671/ + Appliance Module for Schlage + http://www.nexiahome.com/SupportCenter/Pages/supportcenter.aspx?page=support + http://www.nexiahome.com/Products/ProductDetail.aspx?model=043156296347 + U.S. / Canada / Mexico + Schlage It’s easy to remotely operate appliances, lamps and other electronics with Nexia™ Home Intelligence and this simple plug-in module. A Nexia outlet on one end and a regular outlet on the other end mean you don’t sacrifice any plug-in space for your other electrical devices. Nexia makes it easy to manage lights and many other plug-in devices from most web-connected computers, tablets or smart phones. + + +· Remote control appliance module is plug-in simple in any AC outlet. +· Activate incandescent and fluorescent floor and table lamps alike. +· Remotely operate or schedule small compatible appliances too—like fans, video games and stereo components—by plugging into the Nexia compatible module. +· Use Nexia to easily set lighting schedules, creating the appearance that someone’s home when the house is empty. +· On your way home, make lights come on to greet you. +· Forget to turn off a light? Pick up your smart phone and save electricity with one touch. +· Set Nexia to conveniently turn on lights when you enter your access code on your Schlage Home Keypad Lock. + + +Remote management with a Nexia™ Home Intelligence system requires the Nexia Bridge and a monthly subscription of $8.99. + 043156296347 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/655/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/671/xml + + + + diff --git a/openzwave/ge/46201-switch.xml b/openzwave/ge/46201-switch.xml new file mode 100644 index 00000000..3d6ebc18 --- /dev/null +++ b/openzwave/ge/46201-switch.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/0063:3135:4952 + images/ge/46201-switch.png + https://products.z-wavealliance.org/products/3317/ + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to exclude your device, press and release the top button of the wireless smart switch (rocker) to exclude it from the network. + 14291/46201/ZW4008 + In-Wall Smart Switch with QuickFit and SimpleWire enhancements. Revolutionary QuickFit design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. This reduced size coupled with the elimination of heat taps provides a better fit in older style boxes and multi-gang configurations. SimpleWire technology allows line and load to automatically be configured with auto-sensing line-load terminals. All of this is coupled with Z-Wave S2 and Smart Start allows for effortless installation while being safer than ever! + 1. Quickly press ON (Top) button 3 times then immediately press the OFF (Bottom) button 3 times. The LED will flash ON/OFF 5 times when completed successfully. +2. Please use this reset procedure only when the primary controller is missing or inoperable. + U.S. / Canada / Mexico + In-Wall Smart Switch + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3317/46201%20Binder.pdf + 1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network. +2. Once the controller is ready to include your device, press and release the top or bottom of the wireless smart switch(rocker) to include it in the network. +3. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3317/xml + + + + + Sets when the LED on the switch is lit. + + + + + + + Default - normal exclusion + Active - perform a series of button presses to help eliminate accidental exclusion + + + + + + + + + + + + diff --git a/openzwave/ge/46202-switch.xml b/openzwave/ge/46202-switch.xml new file mode 100644 index 00000000..0e0f07ca --- /dev/null +++ b/openzwave/ge/46202-switch.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/0063:3137:4952 + images/ge/46202-switch.png + https://products.z-wavealliance.org/products/3350/ + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to exclude your device, press and release the top button of the wireless smart switch (rocker) to exclude it from the network. + 14292/46202/ZW4009 + In-Wall Smart Switch with QuickFit and SimpleWire enhancements. Revolutionary QuickFit design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. This reduced size coupled with the elimination of heat taps provides a better fit in older style boxes and multi-gang configurations. SimpleWire technology allows line and load to automatically be configured with auto-sensing line-load terminals. All of this is coupled with Z-Wave S2 and Smart Start allows for effortless installation while being safer than ever! + 1. Quickly press ON (Top) button 3 times then immediately press the OFF (Bottom) button 3 times. The LED will flash ON/OFF 5 times when completed successfully. +2. Please use this reset procedure only when the primary controller is missing or inoperable. + U.S. / Canada / Mexico + In-Wall Smart Switch + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3350/46202%20Binder.pdf + 1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network. +2. Once the controller is ready to include your device, press and release the top or bottom of the wireless smart switch(rocker) to include it in the network. +3. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3350/xml + + + + + Sets when the LED on the switch is lit. + + + + + + + Default - normal exclusion + Active - perform a series of button presses to help eliminate accidental exclusion + + + + + + + + + + + + diff --git a/openzwave/ge/46203-dimmer.xml b/openzwave/ge/46203-dimmer.xml new file mode 100644 index 00000000..807baf56 --- /dev/null +++ b/openzwave/ge/46203-dimmer.xml @@ -0,0 +1,74 @@ + + + + + http://www.openzwave.com/device-database/0063:3235:4944 + images/ge/46203-dimmer.png + https://products.z-wavealliance.org/products/3323/ + In-Wall Smart Dimmer + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3323/14294.46203.ZW3010%20Binder.pdf + U.S. / Canada / Mexico + Quickly press ON (Top) button three (3) times then immediately +press the OFF (Bottom) button three (3) times. The LED will flash +ON/OFF 5 times when completed successfully. +NOTE: This should only be used in the event your network’s +primary controller is missing or otherwise inoperable. + 1. Follow the instructions for your Z-Wave certified controller to +include a device to the Z-Wave network. +2. Once the controller is ready to add your device, +press and release the top or bottom of the wireless smart +switch (rocker) to add it in the network. +Please reference the controller’s manual for instructions. + In-Wall Smart Dimmer with QuickFit and SimpleWire enhancements. Revolutionary QuickFit design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. This reduced size coupled with the elimination of heat taps provides a better fit in older style boxes and multi-gang configurations. SimpleWire technology allows line and load to automatically be configured with auto-sensing line-load terminals. All of this is coupled with Z-Wave S2 and Smart Start allows for effortless installation while being safer than ever! + 46203/ZW3010 + 1. Follow the instructions for your Z-Wave certified controller to +remove a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press +and release the top or bottom of the wireless smart dimmer +(rocker) to remove it from the network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3323/xml + + + + + Adjust the LED status to default, invert, always OFF or always ON + + + + + + + Adjust the speed at which the ramps to a specific value other than 0 and FF + + + + + Turn your dimmer into an On/Off switch with switch mode + + + + + Never accidentally remove a device during with alternate exclusion + + + + + Set the minimum dimmer threshold + + + Set the brightness threshold + + + Set the default brightness level that the dimmer will turn on when being controlled manually + + + + + + + + + + + diff --git a/openzwave/ge/46204-dimmer-toggle.xml b/openzwave/ge/46204-dimmer-toggle.xml new file mode 100644 index 00000000..7af260fc --- /dev/null +++ b/openzwave/ge/46204-dimmer-toggle.xml @@ -0,0 +1,67 @@ + + + + + http://www.openzwave.com/device-database/0063:3237:4944 + images/ge/46204-dimmer-toggle.png + https://products.z-wavealliance.org/products/3352/ + In-Wall Smart Toggle Dimmer + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3352/14295.46204%20Binder.pdf + U.S. / Canada / Mexico + Quickly press ON (up) button three times then immediately press the OFF (down) button three times. + NOTE: This should only be used in the event your network’s + primary controller is missing or otherwise inoperable. + 1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network. + 2. Once the controller is ready to add your device, press up and release the toggle. Please reference the controller’s manual for instructions. + Now, you have complete control to turn your fixture ON/OFF or dim according to groups, scenes, schedules and interactive automations programmed by your controller. If your Z-Wave certified controller features remote access, you can control your fixture from your mobile devices. + In-Wall Smart Toggle Dimmer with QuickFit and SimpleWire enhancements. Revolutionary QuickFit design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. This reduced size coupled with the elimination of heat taps provides a better fit in older style boxes and multi-gang configurations. SimpleWire technology allows line and load to automatically be configured with auto-sensing line-load terminals. All of this is coupled with Z-Wave S2 and Smart Start allows for effortless installation while being safer than ever! + 14295/46204/ZW3011 + To remove and reset the device: + 1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network. + 2. Once the controller is ready to remove your device, press up and release the toggle. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/3352/XML + + + + + Adjust the LED status to default, invert, always OFF or always ON + + + + + + + Adjust the speed at which the ramps to a specific value other than 0 and FF + + + + + Turn your dimmer into an On/Off switch with switch mode + + + + + Never accidentally remove a device during with alternate exclusion + + + + + Set the minimum dimmer threshold + + + Set the brightness threshold + + + Set the default brightness level that the dimmer will turn on when being controlled manually + + + + + + + + + + + diff --git a/openzwave/ge/dimmer.xml b/openzwave/ge/dimmer.xml new file mode 100644 index 00000000..4328aaa3 --- /dev/null +++ b/openzwave/ge/dimmer.xml @@ -0,0 +1,65 @@ + + + http://www.openzwave.com/device-database/0063:3230:4457 + images/ge/dimmer.png + https://products.z-wavealliance.org/products/1223/ + U.S. / Canada / Mexico + http://www.jascoproducts.com/support/ + 45762 + 3-way toggle style in-wall dimmer - light almond colo + Jasco In-Wall Dimmer, Toggle, Almond (45762) + www.ezzwave.com + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/293/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/654/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/842/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/844/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/846/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/856/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/893/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/894/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1214/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1215/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1216/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1217/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1220/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1223/xml + + + + + + In night-light mode the LED on the switch will turn ON when the switch is turned OFF. + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch. + + + + + This dimmer will start dimming from its current level. + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + diff --git a/openzwave/ge/dimmer_module.xml b/openzwave/ge/dimmer_module.xml new file mode 100644 index 00000000..2946ec08 --- /dev/null +++ b/openzwave/ge/dimmer_module.xml @@ -0,0 +1,54 @@ + + + http://www.openzwave.com/device-database/0063:3030:4450 + images/ge/dimmer_module.png + https://products.z-wavealliance.org/products/1209/ + http://www.ezzwave.com + 45702/ZW3103 + http://nexiahome.com/SupportCenter/Pages/supportcenter.aspx?page=suppor + U.S. / Canada / Mexico + RF controlled, plug-in dimmer + Jasco lamp module 45702 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/672/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/726/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/888/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1191/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1209/xml + + https://products.z-wavealliance.org/products/1191/ + 12718/ZW3101 + U.S. / Canada / Mexico + + + + + Turn on the module when the attached load is connected + + + + + This dimmer will start dimming from its current level. + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + diff --git a/openzwave/ge/hinge-pin.xml b/openzwave/ge/hinge-pin.xml new file mode 100644 index 00000000..e9eb7700 --- /dev/null +++ b/openzwave/ge/hinge-pin.xml @@ -0,0 +1,33 @@ + + + http://www.openzwave.com/device-database/0063:3032:4953 + images/ge/hinge-pin.png + https://products.z-wavealliance.org/products/1800/ + 32563 / ZW4001 + U.S. / Canada / Mexico + You may wish to reset all of your Hinge Pin Smart Door Sensor's settings to their factory defaults. To do this, press the program button 10 times within 6 seconds. If your Door Sensor has been successfully reset, its LED light will blink for 3 seconds. + +This should only be used in the event your network’s primary controller is missing or otherwise inoperable. + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to exclude your device, press and release the manual/program button on the Hinge Pin Smart Door Sensor to exclude it from the network. + Hinge Pin Smart Door Sensor + Transform any home into a smart home with the GE Hinge Pin Smart Door Sensor. This Smart Door Sensor is universal to fit any hinge size and is also reversible to allow it to work on a right or left opening door. With the adjustable zero pin position this will allow you to easily adjust for molding and when the sensor triggers. With the quick and easy installation, this sensor will notify you of when people enter or exit your home, you can also set the sensor to turn on a light or groups of lights. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1800/32563-1 EnFrSp QSG - Combined.pdf + 1. Press and hold the Z-Wave Button for 6 seconds. It will be wake up and send “Wake Up Notification CC “ to HUB. +2 .It will sleep after timeout for 10 seconds, or sleep right away when received the “Wake Up No More Information CC”. + + 1. Follow the instructions for your Z-Wave certified controller to include the device to the Z-Wave network. +2. Once the controller is ready to include your Hinge Pin Smart Door Sensor press and release the manual/program button on the smart switch to include it in the network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1800/xml + + + + + + + + + + + diff --git a/openzwave/ge/receptacle.xml b/openzwave/ge/receptacle.xml new file mode 100644 index 00000000..4117c3d3 --- /dev/null +++ b/openzwave/ge/receptacle.xml @@ -0,0 +1,50 @@ + + + http://www.openzwave.com/device-database/0063:3530:5252 + images/ge/receptacle.png + https://products.z-wavealliance.org/products/724/ + http://www.jascoproducts.com/support/ + Transform any home into a smart home with the GE Z-Wave Tamper Resistant Smart Outlet. The GE Z-Wave Tamper Resistant Smart Outlet enables wireless control of on/off functions from the Z-Wave controlled outlet, and is compatible with incandescent, LED, Xenon, Halogen, fluorescent and compact fluorescent bulbs. The tamper resistant duplex receptacle includes a blue LED indicator light to easily locate the receptacle in a dark room. The receptacle replaces your current electrical outlet, uses your existing wiring and provides a Z-Wave enabled outlet for the lamp or appliance that you would like to control and a standard pass-through AC outlet for other electrical appliances. Take control of your home lighting with Jasco Z-Wave Smart Lighting Controls! + + U.S. / Canada / Mexico + http://www.ezzwave.com + In-Wall Tamper Resistant Smart Outlet + 45636/ZW1001 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/657/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/724/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1195/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1212/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2732/xml + + https://products.z-wavealliance.org/products/1212/ + U.S. / Canada / Mexico + 45705 + https://products.z-wavealliance.org/products/2732/ + 1. Follow the instructions for your Z-Wave certified controller to +remove a device from the Z-Wave network. +2. Once the controller is ready to remove your device, press and +release the manual/program button to remove it from the +network. + 1. Follow the instructions for your Z-Wave certified +controller to add a device to the Z-Wave network. +2. Once the controller is ready to add your device, press and +release the Program Button to add it in the network. + U.S. / Canada / Mexico + Press the button 3 times, then press and hold the button for at least 3 +seconds. The LED will blink 5 times to confirm. +NOTE: This should only be used in the event your network’s primary +controller is missing or otherwise inoperable + 14288/ZW1002 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2732/14288 QSG v1.pdf + + + + + Sets when the LED on the outlet is lit. + + + + + + diff --git a/openzwave/ge/relay.xml b/openzwave/ge/relay.xml new file mode 100644 index 00000000..28000155 --- /dev/null +++ b/openzwave/ge/relay.xml @@ -0,0 +1,40 @@ + + + http://www.openzwave.com/device-database/0063:3533:5257 + images/ge/relay.png + https://products.z-wavealliance.org/products/1222/ + http://www.ezzwave.com + 3-way relay wall switch - Toggle Style - light almond color + http://www.jascoproducts.com/support/ + 45760 + Jasco In-Wall ON/OFF, Toggle, Almond (45760) + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/653/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/725/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/841/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/845/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1196/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1213/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1219/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1222/xml + + https://products.z-wavealliance.org/products/1196/ + U.S. / Canada / Mexico + 12722 / ZW4005 + + + + + Sets when the LED on the switch is lit. + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. + + + + + diff --git a/openzwave/ge/ze26i.xml b/openzwave/ge/ze26i.xml new file mode 100644 index 00000000..29cf64d5 --- /dev/null +++ b/openzwave/ge/ze26i.xml @@ -0,0 +1,73 @@ + + + http://www.openzwave.com/device-database/0063:3031:4C42 + images/ge/ze26i.png + https://products.z-wavealliance.org/products/2528/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2528/39723 EnFrSp QSG v2..pdf + Smart LED light bulb with Z-Wave radio. +- Control lights remotely and save energy +- Compatible with smart home systems supporting Z-Wave +- 60 Watt equivalent light (750 lumens) +- Consumes only 9 watts of power +- 2700K soft light with frosted glass +- Instant ON and fully dimmable +- Functions as a Z-Wave signal repeater +- Very simple to include in your network +- Z-Wave Plus certified + + 1. Turn off power to the light bulb socket +2. Follow the network controller instruction to place your network controller into exclusion mode to remove the dt light bulb from the network. +3. After being prompted by the network controller, turn On power to the light bulb. If successful, the LED light bulb will flash twice to indicate successful exclusion. + + + U.S. / Canada / Mexico + 1. Turn Off power to the light bulb socket +2. Screw in the light bulb +3. Place your network controller into inclusion mode by following the controller manufacturer's instructions +4. Turn On power to the light bulb. If successful, the LED light bulb will flash twice to indicate successful inclusion. +5. If the controller/gateway shows it was a fail, repeat the procedure. + +Note: If Inclusion still fails after the 2nd attempt, you need to first RESET the dt Smart Bulb before repeating the above steps. + + 39723 + Z-Wave LED Light Bulb + You may manually reset the light bulb as follows: +1. Flick the wall switch “OFF-ON” 4 times within 4 seconds. +2. The dt Smart Bulb will flash twice after Reset is successful. + +Use this procedure only in the event that the network primary controller is lost or otherwise inoperable. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1942/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2528/xml + + + + + + + You may select the dim level whenever the light is turned back ON to be either full brightness (100% dim level) or be the same as the last dim setting when the light is ON by flicking the wall switch + + + + + + You may change the dimming step level when you adjust the brightness by your controller/gateway. + When the value is low, dimming/brightening is gradual. + When the value is high, dimming/brightening is rapid. + + + + + You may change the dimming speed quicker or slower. + When the value is low, the step timing is quick. + When the value is high, the step timing is slow. + + + + + + + + + + diff --git a/openzwave/ge/zw4001-switch.xml b/openzwave/ge/zw4001-switch.xml new file mode 100644 index 00000000..1ee507de --- /dev/null +++ b/openzwave/ge/zw4001-switch.xml @@ -0,0 +1,24 @@ + + + + + + + Sets when the LED on the switch is lit. + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + + + + + + diff --git a/openzwave/ge/zw6302.xml b/openzwave/ge/zw6302.xml new file mode 100644 index 00000000..6899211c --- /dev/null +++ b/openzwave/ge/zw6302.xml @@ -0,0 +1,69 @@ + + + http://www.openzwave.com/device-database/0063:3133:4953 + images/ge/zw6302.png + https://products.z-wavealliance.org/products/1902/ + 34193/ZW6302 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2124/34194 QSG and Parameter List.pdf + U.S. / Canada / Mexico + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. + 2. Once the controller is ready to exclude your device, press and release the program button to exclude it from the network. + Portable Smart Motion Sensor + Make the move toward convenience with the Z-Wave Portable Smart Motion Sensor for your home. +This Z-Wave compatible device boosts the safety of your home by working with your home’s gateway +to wirelessly trigger scenes and send alerts to your smartphone or tablet whenever motion is detected. +Use the included batteries for easy placement anywhere, plug into the wall using a AC adapter and +USB cable – never replace batteries again. + + 1. Press the program button 10 times within 6 seconds. +2. The blue LED will blink for 3 seconds. +Note: This should only be done in the event your primary controller is missing or otherwise inoperable. + 1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network. +2. Once the controller is ready to include your device, press and release the program button to include it in the network. +3. The blue LED will activate for 3 seconds to confirm it has been included. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1902/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2124/xml + Update min/max PIR parameter https://github.com/OpenZWave/open-zwave/issues/2041 + + https://products.z-wavealliance.org/products/2124/ + U.S. / Canada / Mexico + 34194/ZW6302 + + + + + + PIR Sensitivity Setting + + + + + + + 1 to 60 => 1 min to 60 min. + 255 => 5 seconds. + + + + Motion Sensor will send out + + + + + + Enable or Disable the LED indication when PIR is triggered + + + + + + + + + + + diff --git a/openzwave/gocontrol/GC-TBZ48L.xml b/openzwave/gocontrol/GC-TBZ48L.xml new file mode 100644 index 00000000..b5dfee55 --- /dev/null +++ b/openzwave/gocontrol/GC-TBZ48L.xml @@ -0,0 +1,276 @@ + + + + + + + 0 + true + + + + + + 0 = Standard, 1 = Heat Pump + + + + + + + 0 = Gas (no fan w/Heat), 1 = Electric (Fan w/Heat) + + + + + + + 0 = w/Cool, 1 = w/Heat + + + + + + + 0 = no 2nd stage heat, 1 = 2nd stage heat + + + + + + + 0 = no aux heat, 1 = aux heat enabled + + + + + + + 0 = no 2nd stage cool, 1 = 2nd stage cool + + + + + + + 0 = Celsius, 1 = Fahrenheit + + + + + + + Sets the Minimum Off Time (MOT) delay before another heating/cooling cycle can begin + + + + + Sets the Minimum Run Time (MRT) delay before a heating/cooling cycle can turn of + + + + + Sets the minimum separation between heating and cooling setpoints + + + + + Sets the delta from setpoint that stage 1 heating starts + + + + + Sets the delta from setpoint that stage 1 heating stops + + + + + Sets the delta from setpoint that stage 2 heating starts + + + + + Sets the delay from setpoint that stage 2 heating stops + + + + + Sets the delta from setpoint that stage 3 heating starts + + + + + Sets the delta from setpoint that stage 3 heating stops + + + + + Sets the delta from setpoint that stage 1 cooling starts + + + + + Sets the delta from setpoint that stage 1 cooling stops + + + + + Sets the delta from setpoint that stage 2 cooling starts + + + + + Sets the delta from setpoint that stage 2 cooling stops + + + + + Mechanical Status + + + + + + + + + + + + + + SCP Status + + + + + + + + + + + + + Autosend Enable Bits + + + + + + + + + + + + + + + + + + + Display Lock + + + + + + + Sets the time from last button press that the backlight will turn OFF + + + + + Sets the maximum heating setpoint value + + + + + Sets the minimum cooling setpoint value + + + + + Enable or disable thermostat's local scheduler + + + + + + + 0 = Hold, 1 = Run + + + + + + + 0 = No setback, 2 = Un-occupied mode + + + + + + + Heat Setpoint for Unoccupied mode + + + + + Cool Setpoint for Unoccupied mode + + + + + Node number for Remote Sensor 1 + + + + + Temperature of Remote Sensor 1 + + + + + Internal Sensor Temperature Offset + + + + + R1 Sensor Temperature Offset + + + + + Timer to let know when to change or clean the filter + + + + + Maximum allowed value for filter timer + + + + + Heat Timer in hours + + + + + Cool Timer in hours + + + + + Fan purge period for Heat mode + + + + + Fan purge period for Cool mode + + + + diff --git a/openzwave/goodway/td14010.xml b/openzwave/goodway/td14010.xml new file mode 100644 index 00000000..73937158 --- /dev/null +++ b/openzwave/goodway/td14010.xml @@ -0,0 +1,133 @@ + + + RGBW Color LED Dimmer + Good Way RGBW module is used to control RGB/RGBW strips and LED strips or bulbs to create countless colour options and has 6 special scene effects. Its extremely small size allows for easy installation behind wall sockets and switches. Controlled devices may be powered by 12 or 24 VDC. + http://www.openzwave.com/device-database/0068:000b:0003 + http://www.goodway.com.tw/product3.asp?listid=9&id=26&subid=102&id=1168&typeid= + + images/goodway/td14010.png + + Connect the module to the power supply. Enable inclusion mode on your Z-Wave controller. Press and release the Include/Exclude button 3 times within 2 seconds. + Connect the module to the power supply. Make sure the module is within direct range of your Z-Wave controller or use a hand-held Z-Wave remote to perform exclusion. Press and release the Include/Exclude button 3 times within 2 seconds. NOTE: The module will be excluded from your network, but any custom configuration parameters will not be erased. + Connect the module to the power supply. Press and hold the Include/Excude button for at least 10 seconds. NOTE: By resetting the module, all custom parameters previously set on the module will return to their default values and the owner ID will be deleted. Use this reset procedure only when the main controller is missing or otherwise inoperable. + https://products.z-wavealliance.org/products/2466/features + U.S. / Canada / Mexico + Good Way RGBW Dimmer + + Initial release + Added indexes 8 and 9 to CC 112 + Removed indexes 8 and 9 to CC 112 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + This parameter is used to adjust time between 2 Colours in the Scene. + 1-127 – delay duration is 1 sec to 127 sec. + 1001-1127 – delay duration is from 1 min to 127 min. This parameter has no effect on lighting and Dancing scenes. + + + Device will be set to status memorized before power cut. + + + + + + + + NOTE: The minimum level may not be higher than the MAX dimming value. + + + + Default value 10 = 1 s. + 5–25 = from 0.5 to 2.5 seconds + + + + 1–127 = from 1 to 127 seconds. + NOTE: Dimming time depends also on Min and Max dimming value. + + + + + NOTE: If the parameter no. 14 is enabled, parameter no. 1,2,3,4 has no effect. + NOTE: After parameter change, first exclude device (without setting parameters to default value) and then re include the device. + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/gr/gr-302n.xml b/openzwave/gr/gr-302n.xml new file mode 100644 index 00000000..f1257664 --- /dev/null +++ b/openzwave/gr/gr-302n.xml @@ -0,0 +1,22 @@ + + + http://www.openzwave.com/device-database/0152:0003:0500 + images/gr/gr-302n.png + https://products.z-wavealliance.org/products/1722/ + PIR Sensor + Press the button unlock and lock-unlock 1 time it will be wake up 10 seconds. + GR-302N + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1722/PIR Sensor_UM.pdf + U.S. / Canada / Mexico + Press the button unlock and lock-unlock 6 times the device will send the reset notification to the list node in the group 1 and erases the device memory. +Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + Please press the Z-Wave button in the pir sensor when the Z-Wave controller sends the instructions for inclusion, Press the Button: unlock and lock-unlock 1 time will send the NIF + This PIR motion sensor can association lighting switch , until leave the detect area. This PIR have support power supply and you don't replace the battery anymore. + Please press the Z-Wave button in the pir sensor when the Z-Wave controller sends the instructions for exclusion, Times to Press the Button: unlock and lock-unlock 1 time will send the NIF + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1722/xml + + + diff --git a/openzwave/gr/gr105.xml b/openzwave/gr/gr105.xml new file mode 100644 index 00000000..77b26daf --- /dev/null +++ b/openzwave/gr/gr105.xml @@ -0,0 +1,22 @@ + + + http://www.openzwave.com/device-database/0152:0511:0202 + images/gr/gr105.png + https://products.z-wavealliance.org/products/1008/ + GR-105 + U-Fairy Control Valve + Auto Valve - Turn on/off water valve or gas valve + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1008/xml + + + + + + + + + + + diff --git a/openzwave/gr/gr105n.xml b/openzwave/gr/gr105n.xml new file mode 100644 index 00000000..105903fc --- /dev/null +++ b/openzwave/gr/gr105n.xml @@ -0,0 +1,37 @@ + + + http://www.openzwave.com/device-database/0152:0512:0003 + images/gr/gr105n.png + https://products.z-wavealliance.org/products/2648/ + 1. Follow the instructions for your Z-Wave certified Controller to enter exclusion mode. +2. When prompted, press the “open/close” button on the Shut-Off quickly 3 times in a row. + The Dome™ Home Automation DMWV1 Water Main Shut-off is designed to fit over existing ¼ turn ball-valves for pipes sized up to 1½ inch. No professional plumbing contractor is required- it can be installed by a homeowner with just a screwdriver. This device requires a Z-Wave Certified hub for operation. When configured with a Water Leak Sensor, the Water Main Shut-off can automatically cut off the supply to limit the damage. You can also remotely control the valve position using your smarthome system mobile app. Extra-long Z-Wave wireless range (up to 150 ft) allows you to place it where it’s needed without worrying if the signal is reaching your Z-Wave Hub. Also functions as Z-Wave signal extender. Dome™ DMWV1 Water Main Shut-off comes with a 1-year limited warranty. Measurements in inches: 2.5 x 3.5 x 6. Dome™ Home Automation Z-Wave devices give your family peace of mind and security you can count on. With Dome™, you’re always connected and always covered. + +• Installs over existing valve without need of a plumber using just a screw driver. Works with ¼ turn ball-valves on pipes sized up to 1½ inch +• Open/Close valve control allowing for automatic water shut-off when leaks are detected as well as on demand control using your smarthome mobile app. +• Up to 150-foot range. Functions as Z-Wave signal extender +• Z-Wave Plus Certified. Requires a Z-Wave Certified Hub to operate + Water Main Shut-Off + Press and hold the open/close button for at least 10 seconds then release. The Shut-Off’s memory will be erased to factory settings. A flashing light indicates a successful factory reset. Beware that resetting your device will disconnect it from your system. Only do this if the controller is missing or otherwise unreachable! + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2648/Dome Water Main Shut-Off Advanced Manual.pdf + 1. For proper inclusion, bring the Water Main Shut-Off to the final location where it will be used. * +2. Follow the instructions for your Z-Wave controller to enter inclusion mode. +3 Make sure the Water Main Shut-Off is powered on, and when prompted by your controller, press the “open/close” button quickly 3 times in a row. The LED will stop blinking and stay on continuously upon successful inclusion. +*For non Z-Wave Plus networks, please consult the owner’s manual for your primary controller to determine the best method and location for adding the Water Main Shut-Off to your Z-Wave network. + U.S. / Canada / Mexico / South Africa / Australia / New Zealand + DMWV1 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1537/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2647/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2648/xml + + + + + + + + + + + diff --git a/openzwave/gr/grb3.xml b/openzwave/gr/grb3.xml new file mode 100644 index 00000000..4e67a8e2 --- /dev/null +++ b/openzwave/gr/grb3.xml @@ -0,0 +1,9 @@ + + + + + 2 + true + + + diff --git a/openzwave/graber/brz1.xml b/openzwave/graber/brz1.xml new file mode 100644 index 00000000..e74dcff2 --- /dev/null +++ b/openzwave/graber/brz1.xml @@ -0,0 +1,36 @@ + + + http://www.openzwave.com/device-database/026E:5A31:4252 + images/graber/brz1.png + https://products.z-wavealliance.org/products/1787/ + U.S. / Canada / Mexico + The Wakeup command class should be configured by a hub when the remote is joined to a Z-Wave network. A WAKE_UP_INTERVAL_SET command should configure the NodeID at a minimum. The Wakeup interval can be configured to any value from 6 minutes to 25 hours. Recommendation is to leave the interval at the default of 12 hours to maximize battery life. The remote will wake up every WakeUpInterval and send a WakeUp Notification command as well as a battery report to the NodeID assigned with the Interval Set command. The WakeUp Notification will be sent within a few minutes of power being applied to the remote and then once every Wake Up Interval. A Wakeup Interval Capabilities command will inform the hub of the default, minimum, maximum and step size of the Wake Up interval. + Enjoy the comfort, convenience and energy efficiency of beautiful custom motorized window treatments featuring Z-Wave protocol for easy integration. Lighting control has never been more simple. Window treatments can be automated using your favorite Z-Wave certified gateway or security system, or controlled by a remote control. Raise or lower the shades to control just the right amount of light, privacy and solar heat. Shades can be fully open, fully closed or anywhere in between, it’s up to you. In addition, some systems will also report back the state of the battery charge on battery operated versions. + Press and hold the button on the control for approximately 15 seconds (the LED will stop flashing when complete. + + +"Please use this procedure only when the network primary controller is missing or otherwise inoperable." + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1787/Graber Virtual Cord Owner's Manual.pdf + BRZ1 + Basic Remote Control Z-Wave + 1. Press and release Twice on Control Programming button. (Tap 2x on prog button) + +2.Slave sends NIF + + 1. Press and release Three times on Control Programming button. (Tap 3x on prog button) + +2. Slave sends NIF + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1787/xml + + + + + + + + + + + + diff --git a/openzwave/graber/csz1.xml b/openzwave/graber/csz1.xml new file mode 100644 index 00000000..c3786929 --- /dev/null +++ b/openzwave/graber/csz1.xml @@ -0,0 +1,29 @@ + + + http://www.openzwave.com/device-database/026E:5A31:4353 + images/graber/csz1.png + https://products.z-wavealliance.org/products/1749/ + 1. Put Primary Controller into +Inclusion Mode + +2. Press and Hold Shade Programming Button for >2seconds + + U.S. / Canada / Mexico + The Wakeup command class should be configured by a hub when the remote is joined to a Z-Wave network. A WAKE_UP_INTERVAL_SET command should configure the NodeID at a minimum. The Wakeup interval can be configured to any value from 6 minutes to 25 hours. Recommendation is to leave the interval at the default of 12 hours to maximize battery life. The remote will wake up every WakeUpInterval and send a WakeUp Notification command as well as a battery report to the NodeID assigned with the Interval Set command. The WakeUp Notification will be sent within a few minutes of power being applied to the remote and then once every Wake Up Interval. A Wakeup Interval Capabilities command will inform the hub of the default, minimum, maximum and step size of the Wake Up interval. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1749/Graber Virtual Cord Owner's Manual 0002.pdf + Please use this procedure only when the network primary controller is missing or otherwise inoperable + +Press and hold the button on the shade for approximately 15 seconds (the LED will stop flashing when complete) + Enjoy the comfort, convenience and energy efficiency of beautiful custom motorized window treatments featuring Z-Wave protocol for easy integration. Lighting control has never been more simple. Window treatments can be automated using your favorite Z-Wave certified gateway or security system, or controlled by a remote control. Raise or lower the shades to control just the right amount of light, privacy and solar heat. Shades can be fully open, fully closed or anywhere in between, it’s up to you. In addition, some systems will also report back the state of the battery charge on battery operated versions. + Cellular Shade Radio Z-Wave + 1. Put Primary Controller into +Exclusion Mode + +2. Press and Hold Shade Programming Button for >2seconds + + CSZ1 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1749/xml + + + diff --git a/openzwave/graber/mcz1.xml b/openzwave/graber/mcz1.xml new file mode 100644 index 00000000..9fafd8ca --- /dev/null +++ b/openzwave/graber/mcz1.xml @@ -0,0 +1,35 @@ + + + + Multi-Channel Remote + Enjoy the comfort, convenience and energy efficiency of beautiful custom motorized window treatments featuring Z-Wave protocol for easy integration. Lighting control has never been more simple. Window treatments can be automated using your favorite Z-Wave certified gateway or security system, or controlled by a remote control. Raise or lower the shades to control just the right amount of light, privacy and solar heat. Shades can be fully open, fully closed or anywhere in between, it’s up to you. In addition, some systems will also report back the state of the battery charge on battery operated versions. + http://www.openzwave.com/device-database/026e:5a31:4d43 + https://www.baliblinds.com/globalassets/3.-documents/installation-instructions/bali-motorization-owners-manual-autoview.pdf + https://www.baliblinds.com/customer-support/ + images/graber/mcz1.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2819/P2_79083-01_18-8215_MotorizationManual.pdf + Any button press will wake up the remote. + 1. From your home automation system’s user interface, select the option to enroll a new Z-Wave device. See your home automation system’s instructions for details. +2. On the remote, press and hold the MENU/RIGHT button to enter the menu. +3. Select ZWAVE > LEARN. + 1. From your home automation system’s user interface, select the option to exclue a Z-Wave device. See your home automation system’s instructions for details. +2. On the remote, press and hold the MENU/RIGHT button to enter the menu. +3. Select ZWAVE > LEARN. + 1. Press and hold the MENU/RIGHT button for 2 seconds to enter the menu. +2. Select ZWAVE > RESET. +3. With LIKE NEW? selected, press and hold the MENU/RIGHT button until the screen no longer tells you to wait. + https://products.z-wavealliance.org/products/2819 + U.S. / Canada / Mexico + MCZ1 + + Initial entry with data obtained from https://products.z-wavealliance.org/products/2819 + + + + + + + + + + diff --git a/openzwave/graber/rsz1.xml b/openzwave/graber/rsz1.xml new file mode 100644 index 00000000..f0b9b381 --- /dev/null +++ b/openzwave/graber/rsz1.xml @@ -0,0 +1,29 @@ + + + http://www.openzwave.com/device-database/026E:5A31:5253 + images/graber/rsz1.png + https://products.z-wavealliance.org/products/1785/ + 1. Put Primary Controller into +Exclusion Mode + +2. Press and Hold Shade Programming Button for >2seconds + + Enjoy the comfort, convenience and energy efficiency of beautiful custom motorized window treatments featuring Z-Wave protocol for easy integration. Lighting control has never been more simple. Window treatments can be automated using your favorite Z-Wave certified gateway or security system, or controlled by a remote control. Raise or lower the shades to control just the right amount of light, privacy and solar heat. Shades can be fully open, fully closed or anywhere in between, it’s up to you. In addition, some systems will also report back the state of the battery charge on battery operated versions. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1785/Graber Virtual Cord Owner's Manual.pdf + Press and hold the button on the shade for approximately 15 seconds (the LED will stop flashing when complete). + +"Please use this procedure only when the network primary controller is missing or otherwise inoperable." + 1. Put Primary Controller into +Inclusion Mode + +2. Press and Hold Shade Programming Button for >2seconds + + Roller Shade Radio Z-Wave + RSZ1 + The Wakeup command class should be configured by a hub when the remote is joined to a Z-Wave network. A WAKE_UP_INTERVAL_SET command should configure the NodeID at a minimum. The Wakeup interval can be configured to any value from 6 minutes to 25 hours. Recommendation is to leave the interval at the default of 12 hours to maximize battery life. The remote will wake up every WakeUpInterval and send a WakeUp Notification command as well as a battery report to the NodeID assigned with the Interval Set command. The WakeUp Notification will be sent within a few minutes of power being applied to the remote and then once every Wake Up Interval. A Wakeup Interval Capabilities command will inform the hub of the default, minimum, maximum and step size of the Wake Up interval. + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1785/xml + + + diff --git a/openzwave/graber/vcz1.xml b/openzwave/graber/vcz1.xml new file mode 100644 index 00000000..b0ac72df --- /dev/null +++ b/openzwave/graber/vcz1.xml @@ -0,0 +1,38 @@ + + + http://www.openzwave.com/device-database/026E:5A31:5643 + images/graber/vcz1.png + https://products.z-wavealliance.org/products/1786/ + Virtual Cord Remote Control Z-Wave + VCZ1 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1786/Graber Virtual Cord Owner's Manual.pdf + Enjoy the comfort, convenience and energy efficiency of beautiful custom motorized window treatments featuring Z-Wave protocol for easy integration. Lighting control has never been more simple. Window treatments can be automated using your favorite Z-Wave certified gateway or security system, or controlled by a remote control. Raise or lower the shades to control just the right amount of light, privacy and solar heat. Shades can be fully open, fully closed or anywhere in between, it’s up to you. In addition, some systems will also report back the state of the battery charge on battery operated versions. + 1. Press and release Three times on Control Programming button. (Tap 3x on prog button) + +2. Slave sends NIF + + + U.S. / Canada / Mexico + Press and hold the button on the control for approximately 15 seconds (the LED will stop flashing when complete. + +"Please use this procedure only when the network primary controller is missing or otherwise inoperable." + The Wakeup command class should be configured by a hub when the remote is joined to a Z-Wave network. A WAKE_UP_INTERVAL_SET command should configure the NodeID at a minimum. The Wakeup interval can be configured to any value from 6 minutes to 25 hours. Recommendation is to leave the interval at the default of 12 hours to maximize battery life. The remote will wake up every WakeUpInterval and send a WakeUp Notification command as well as a battery report to the NodeID assigned with the Interval Set command. The WakeUp Notification will be sent within a few minutes of power being applied to the remote and then once every Wake Up Interval. A Wakeup Interval Capabilities command will inform the hub of the default, minimum, maximum and step size of the Wake Up interval. + 1. Press and release Twice on Control Programming button. (Tap 2x on prog button) + +2.Slave sends NIF + + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1786/xml + + + + + + + + + + + + diff --git a/openzwave/greenwave/gs1110-1-gr-1.xml b/openzwave/greenwave/gs1110-1-gr-1.xml new file mode 100644 index 00000000..f6bbcfc9 --- /dev/null +++ b/openzwave/greenwave/gs1110-1-gr-1.xml @@ -0,0 +1,17 @@ + + + http://www.openzwave.com/device-database/0099:0002:0001 + images/greenwave/gs1110-1-gr-1.png + https://products.z-wavealliance.org/products/834/ + GS1110-1-GR-1 + The GreenWave Reality Home Energy Management service provides robust monitoring and control of devices in the home. The initial installation typically includes a Gateway, intelligent power strips (PowerNodes), and integration with third-party smart thermostats. Consumers can extend conservation efforts and further simplify their lives by creating easy-to-configure Smart Controls that can be executed by the push of a button – or at scheduled times – to turn devices or entire rooms on or off. + +GreenWave Reality’s focus on the consumer begins with a guided out-of-box experience that includes videos, an Energy Coach and a range of patented technologies that enable users to quickly get up and running on their own. After connecting the Gateway and plugging devices into the PowerNodes, the DeviceDNA feature automatically helps identify the type of each device for simple configuration of the system. + http://www.greenwavereality.com/ + OneGateway + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/834/xml + + + diff --git a/openzwave/greenwave/powernode1.xml b/openzwave/greenwave/powernode1.xml new file mode 100644 index 00000000..91ce766c --- /dev/null +++ b/openzwave/greenwave/powernode1.xml @@ -0,0 +1,67 @@ + + + http://www.openzwave.com/device-database/0099:0002:0002 + images/greenwave/powernode1.png + https://products.z-wavealliance.org/products/629/ + Single-socket PowerNode, UK.The single port version of the PowerNode, these devices communicate wirelessly to the Gateway, allowing for energy monitoring and device control. Our products come pre-configured to connect to the Gateway with minimal consumer set-up. + CEPT (Europe) / Australia / New Zealand / U.S. / Canada / Mexico / CEPT (Europe) + Greenwave Single socket PowerNode UK + http://www.greenwavereality.com/solutions/energymgmt/ + NS210-G-EN/NP210-G-EN + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/52/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/55/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/58/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/589/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/629/xml + + http://www.greenwavereality.com/solutions/energymgmt/ + + + + + Consumer variation required to send notification. + From 1 to 100, default 10 + + + After how many minutes the GreenWave device should start flashing if the controller didn't communicate with this device + + + The room color (Corner wheel color) on the GreenWave device + + + + + + + + + + + + + Relais state after a power loss + + + + + + Enable/Disable the LED on network error + + + + + + + + + + + + + + + + + + diff --git a/openzwave/greenwave/powernode6.xml b/openzwave/greenwave/powernode6.xml new file mode 100644 index 00000000..05f0f2fe --- /dev/null +++ b/openzwave/greenwave/powernode6.xml @@ -0,0 +1,71 @@ + + + http://www.openzwave.com/device-database/0099:0004:0003 + images/greenwave/powernode6.png + https://products.z-wavealliance.org/products/590/ + http://www.greenwavereality.com/solutions/energymgmt/ + Australia / New Zealand / CEPT (Europe) / CEPT (Europe) / U.S. / Canada / Mexico + The PowerNode 6-Port allows users to connect up to 6 appliances, making them smart, energy conscious and controllable. Our patent-pending DeviceDNA technology instantly recognizes the device upon being plugged into the PowerNode, to facilitate identification of your devices. + Multi socket PowerNode US + MP220-B/NP222-B + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/54/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/56/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/57/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/590/xml + + http://www.greenwavereality.com/about/contact/ + + + + + Consumer variation required to send notification. + From 1 to 100, default 10 + + + After how many minutes the GreenWave device should start flashing if the controller didn't communicate with this device + + + The room color (Corner wheel color) on the GreenWave device + + + + + + + + + + + + + Relais state after a power loss + + + + + + Enable/Disable the LED on network error + + + + + + + true + + + + + + + + + + + + + + + + diff --git a/openzwave/guardtec/gkw2000d.xml b/openzwave/guardtec/gkw2000d.xml new file mode 100644 index 00000000..bddc2038 --- /dev/null +++ b/openzwave/guardtec/gkw2000d.xml @@ -0,0 +1,52 @@ + + + GKW-2000D + The GKW-2000D is a secure electronic door lock + http://www.openzwave.com/device-database/037B:0001:0002 + http://gkw2000d.thekeywe.com + https://mykeywe.thekeywe.com/Home/Login + images/guardtec/gkw2000d.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2905/GKW-2000DZ-WaveManual.pdf + press the [REG] button, enter the Master Pin (Default:1234) on the keypad followed by #88* + press the [REG] button, enter the Master Pin (Default:1234) on the keypad followed by #99* + press the [REG] button, enter the Master Pin (Default:1234) on the keypad followed by #5*2*[Master Pin]# + https://products.z-wavealliance.org/products/3060/ + https://products.z-wavealliance.org/products/3062/ + https://products.z-wavealliance.org/products/3030/ + https://products.z-wavealliance.org/products/3064/ + https://products.z-wavealliance.org/products/2905/ + https://products.z-wavealliance.org/products/3061/ + https://products.z-wavealliance.org/products/3063/ + https://products.z-wavealliance.org/products/3029/ + https://products.z-wavealliance.org/products/2993/ + Malaysia + Singapore + South Korea + Thailand + U.S. / Canada / Mexico + Brazil + Taiwan + Australia / New Zealand + CEPT (Europe) + + Refresh lock status when alarm message received + Initial Metadata import + + + + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/hab/iblindsV2.xml b/openzwave/hab/iblindsV2.xml new file mode 100644 index 00000000..fdb0e620 --- /dev/null +++ b/openzwave/hab/iblindsV2.xml @@ -0,0 +1,52 @@ + + + http://www.openzwave.com/device-database/0287:000D:0003 + images/hab/iblinds.png + https://products.z-wavealliance.org/products/2486/ + The Device Reset Locally function is used to reset the device to fatory default. The reset operation resets protocol data (HomeID, NodeID) as well as all application specific data to factory default values. +NOTE: Please only use this function when the primary controller is missing or inoperable! +1. Press the INC / EXC button 3 +Press the INC / EXC button 3 times within 5 seconds to enable the device reset function. +2. Wait 30 Seconds Press CLBR button +After device is reset wait 30 seconds and press the CLBR button to reboot the device and make it ready for Z-Wave Inclusion. + iblindsV2 + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2486/iBlind_User_Guide.pdf + An intelligent Z-Wave blind motor that installs out of sight in existing Horizontal (2" and 2 1/2" slatted-style) blind headrails. Use iBlinds to tilt the slats open, closed or use the value slider for precise positioning of the slat tilt angle. + Follow the directions for your Z-Wave device to place it in the exclusion mode. +Press the exclude button once and wait for the device to be removed from the Z-Wave network. + + iblinds V2 + U.S. / Canada / Mexico + Follow the directions for your Z-Wave hub/controller to place it in the add for inclusion mode. +Press the inclusion button once and wait for the device to be discovered and joined to the Z-Wave network. Follow the directions of your Z-Wave controller to uniquely identify your iblinds device. (Ex: Bedroom iblind) +Note: If the device is not joined to the network. Press the CLBR button Wait 1 minutes and repeat steps 1 and 2 again. If you continue to have trouble joining the iblinds motor to the Z-Wave network follow the Z-Wave network Exclusion process below. + + + Initial metadata + Folder namechange to hab, minor typos + + + + + + true + + + + + Changing the Auto Calibration torque will allow you to change the initial calibration torque. Use at your own risk! + + + + + + + + + + + + + + + diff --git a/openzwave/hab/iblindsV3.xml b/openzwave/hab/iblindsV3.xml new file mode 100644 index 00000000..b94e49a7 --- /dev/null +++ b/openzwave/hab/iblindsV3.xml @@ -0,0 +1,71 @@ + + + iblinds + An intelligent blind motor, a Z-Wave device designed for tilting Venetian (two inch slatted-style) blinds. Open and close the blinds and use a value slider for precise positioning of the tilt angle. + http://www.openzwave.com/device-database/0287:0071:0004 + https://myiblinds.com/ + https://support.myiblinds.com + images/hab/iblindsV3.png + http://support.myiblinds.com/wp-content/uploads/2019/06/User-Guide-v1.0.pdf + Press Include/Exclude button + Follow the directions for your Z-Wave hub/controller to place it into inclusion mode. Press the inclusion button three times and wait for the device to be discovered and joined to the Z-Wave network. + Follow the directions for your Z-Wave device to place it in the exclusion mode. Press the exclude button three times and wait for the device to be removed from the Z-Wave network. + Charge adapter button can be used to reset the device and perform manual auto calibration: press and hold the Charge Adapter button for 10 seconds. + https://products.z-wavealliance.org/products/2486/features + U.S. / Canada/ Mexico + CEPT + Australia / New Zealand + iblinds V3 + + + Initial Release + + + + + + + Auto Calibration Tightness + Lower value = tighter + Higher value = looser + MUST BE RECALIBRATED + Range:16-32 + Default: 22 + + + + + Reverse closing direction + + + + + + + + Value that iblinds will open to by Default + Default: 50 + + + + + Will disable the reset button on the motor, preventing it from accidentally being pressed + + + + + + + How fast iblinds will close in seconds + Default:0 + + + + + + + + + + + diff --git a/openzwave/hank/hkzw-dws01.xml b/openzwave/hank/hkzw-dws01.xml new file mode 100644 index 00000000..22ac7cd8 --- /dev/null +++ b/openzwave/hank/hkzw-dws01.xml @@ -0,0 +1,68 @@ + + + http://www.openzwave.com/device-database/0208:0008:0201 + images/hank/hkzw-dws01.png + https://products.z-wavealliance.org/products/2775/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2844/DoorWindowSensorEngineeringSpecification.pdf + 1. Insert the AAA battery. +2. Set the Z-Wave network main controller into learning mode. +3. Triple or single short press the Z-button. +4. If the add for inclusion is successful, the LED will blink less than 5 seconds and then keep on 3 seconds. Otherwise, the LED will blink 5 seconds and then turn off, in which case you need to repeat the process from step 2. + + 1. Insert the AAA battery. +2. Pressing and holding the Z button for more than 20 seconds, +3. Led will keep on until the Z-Button is released, and it will reset to factory default when the button is released. + +Using this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + HKZW-DWS01 + Door/Window Sensor is a wireless reed sensor powered by AAA battery. It is used for detecting the opening or closing of doors, windows. It can communicate with an associated Z-Wave device, such as Siren, Smart Switch, etc. + 1. Insert the AAA battery. +2. Set the Z-Wave network main controller into learning mode. +3. Triple clicking the Z-button. +4. If the remove for exclusion, the LED will turn off within 1 second. Otherwise, the LED will blink 5 seconds and then turn off, in which case you need to repeat the process from step 2. + + + U.S. / Canada / Mexico + Door/Window Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1892/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1896/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2775/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2844/xml + + https://products.z-wavealliance.org/products/2844/ + HKZW-DWS01 + CEPT (Europe) + + + + + + Enable/Disable BASIC SET command + + + + + + Send BASIC SET VALUE = 255 to nodes associated with group 2 when door/window is opened. + Send BASIC SET VALUE = 0 to nodes associated with group 2 when door/window is closed. + + + + + The value here defines the low battery + + + + + + + + + + diff --git a/openzwave/hank/hkzw-fld01.xml b/openzwave/hank/hkzw-fld01.xml new file mode 100644 index 00000000..3f63ef1d --- /dev/null +++ b/openzwave/hank/hkzw-fld01.xml @@ -0,0 +1,111 @@ + + + http://www.openzwave.com/device-database/0208:000F:0200 + images/hank/hkzw-fld01.png + https://products.z-wavealliance.org/products/2641/ + Flood Sensor is capable of both detecting leaks and floods and when the level of water gets too low in pool or tank, Flood Sensor can work with your z-wave network to prevent emergencies such as burst water boiler to leaking air conditioners. With Z-Wave, the scope to save money is endless. + +The features list: +1) Z-Wave Plus certified for wide compatibility (500 serials product). +2) Security 0 and security 2 framework implemented with AES-128 encryption. +3) Contains an extension water detecting probe. +4) Temperature measurement. +5) Vibration sensor. +6) The battery life is up to 1 year. +7) Low battery alert + + 1)Power on the device, +2) Press and hold the Z button for more than 20 seconds, +3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete. +4) The reset feature works only when the device has been included into a Z-Wave network. + +Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + + + Press and hold the Z button for more than 5 seconds and release. + Flood Sensor + 1) Open the cover. +2) Place the device within the direct range of your Z-Wave controller. +3) Set the main controller remove mode (see the controller’s manual). +4) Triple click the Z-button quickly, the LED indicator should blink fast. +5) Wait for the removing process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + HKZW-FLD01 + 1) Open the cover. +2) Place the device within the direct range of your Z-Wave controller. +3) Set the main controller in add mode (see the controller’s manual). +4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast. +5) Wait for the adding process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2641/Flood Sensor Specification Engineering.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2641/xml + + + + + + + + The Flood sensor can send BASIC SET command to nodes associated with group 2. + + + + + The Flood sensor can reverse its value of BASIC SET when flooding is triggered. + + + + + + + + + + + + + + + + + + + + US: -670 - 2570 (-67 - 257 F) + Other: -550 - 1250 (-55 - 125 C) + + + + + + + + US: -670 - 2570 (-67 - 257 F) + Other: -550 - 1250 (-55 - 125 C) + + + + + + + + This parameter defines a battery level as the "low battery". + + + + + + + + + + diff --git a/openzwave/hank/hkzw-ms01.xml b/openzwave/hank/hkzw-ms01.xml new file mode 100644 index 00000000..3217bd9d --- /dev/null +++ b/openzwave/hank/hkzw-ms01.xml @@ -0,0 +1,111 @@ + + + http://www.openzwave.com/device-database/0208:0006:0200 + images/hank/hkzw-ms01.png + https://products.z-wavealliance.org/products/2305/ + HKZW-MS01 + Remove for exclusion; +1. Insert two CR123A batteries. +2. Set the Z-Wave network main controller into removing mode (see Z-Wave controller operating manual). +3. Triple clicking the Z-button. +4. If the removing is successful, the LED will blink slowly for 5 seconds and then turn off, otherwise you need to repeat the process from step 2. + CEPT (Europe) + 2. Add for inclusion (non-security): +1) Insert two CR123A batteries. +2) Set the Z-Wave network main controller into learning mode (see Z-Wave network controller operating manual). +3) Triple clicking the Z-button. +4) If the inclusion is successful, the LED will blink less than 5 seconds and then keep on for 3 seconds, otherwise the LED will blink 5 seconds and then turn off, in which you need to repeat the process from step 2. +Add for inclusion (security): +1) Insert two CR123A batteries. +2) Set the Z-Wave network main controller into learning mode (see Z-Wave network controller operating manual). +3) Press and hold the Z-button for 3 seconds. +4) If the inclusion is successful, the LED will blink fast for less than 5 seconds and then keep on for 3 seconds, otherwise the LED will blink fast for 5 seconds and then turn off, in which you need to repeat the process from step 2. + + Press and hold the Z-button for 20 seconds, +Multisensor will send “Device_Reset_Locally” to the main controller and exclude from the Z-Wave network when the Z-Button is released, this procedure will reset the Sensor to factory default. +Please include a request to use the reset procedure only when the primary controller is missing or inoperable. + Multisensor + Multisensor is a universal Z-Wave device. Along with detecting motion the device measures the temperature, humidity and luminance . It can communicate with associated Z-Wave devices, such as Siren, Smart Switch, etc. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2305/HKZW-MS01 MANUL.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2305/xml + + + + + + + + Level 0 to 8. + 0 Disabled. + + + + Insensitivity + + + Enable/Disable BASIC SET command + + + + + + Send BASIC SET VALUE = 255 to nodes associated with group 2 when door/window is opened. + Send BASIC SET VALUE = 0 to nodes associated with group 2 when door/window is closed. + + + + + The low level from 10% to 50% + + + + + + + + The interval of sending battery report + + + The interval of sending temperature report + + + The interval of sending Humidity report + + + The interval of sending luminance report + + + The change in battery level resulting in battery report being sent to the main controller. + + + + 0 reports are not sent. + 1 to 255 the change in temperature level resulting in temperature report being sent to the main controller. + + + + + 0 reports are not sent. + 1 to 100 the change in humidity level resulting in humidity report being sent to the main controller. + + + + + 0 Reports are not sent. + 1 to 65535 the change in luminance level resulting in luminance report being sent to the main controller. + + + + + + + + + + + diff --git a/openzwave/hank/hkzw-ms02-200.xml b/openzwave/hank/hkzw-ms02-200.xml new file mode 100644 index 00000000..02a148f3 --- /dev/null +++ b/openzwave/hank/hkzw-ms02-200.xml @@ -0,0 +1,94 @@ + + + http://www.openzwave.com/device-database/0208:0012:0200 + images/hank/hkzw-ms02-200.png + https://products.z-wavealliance.org/products/2578/ + 1)Power on the device, +2) Press and hold the Z button for more than 20 seconds, +3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete. +4) The reset feature works only when the device has been included into a Z-Wave network. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + Motion sensor can be included and operated in any Z-Wave network with other Z-Wave certified devices. + +The features list: +1) Z-Wave Plus certified for wide compatibility (500 serials product). +2) Supports security 0 and security 2 protected mode with AES-128 encryption. +3) Motion sensor. +4) Tamper alarm by shock sensor. +5) The battery life is up to 1 year. +6) Low battery alarm. +7) Support firmware OTA. + + 1) Open the cover. +2) Place the device within the direct range of your Z-Wave controller. +3) Set the main controller in add mode (see the controller’s manual). +4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast. +5) Wait for the adding process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2578/HKZW-MS02-ProductManual.pdf + HKZW-MS02 + Motion Sensor + Press and hold the Z button for more than 5 seconds and release. + 1) Open the cover. +2) Place the device within the direct range of your Z-Wave controller. +3) Set the main controller remove mode (see the controller’s manual). +4) Triple click the Z-button quickly, the LED indicator should blink fast. +5) Wait for the removing process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2578/xml + Adjust description and units of configuration parameter 18 as per user manual + + + + + + + + Level 1 to 8. The higher the value, the more sensitive the PIR sensor. + 0 Disabled. + + + + Enable/disable basic set command + + + + + + Send basic set value = 255 to nodes associated with group 2 when motion alarm is triggered. Send basic set value = 0 to nodes associated with group 2 when motion alarm is canceled. + Send basic set value = 0 to nodes associated with group 2 when motion alarm is triggered. Send basic set value = 255 to nodes associated with group 2 when motion alarm is canceled. + + + + + when the value is 0, the product will not sends a vibration alarm after moving or shaking; when the value is 1, the product will sends a vibration alarm after moving or shaking + + + + + The number of seconds to delay the alarm cancellation after motion has not been detected any longer. + + + The low level from 10% to 50% + + + + + + + + + + diff --git a/openzwave/hank/hkzw-ms02-300.xml b/openzwave/hank/hkzw-ms02-300.xml new file mode 100644 index 00000000..6ad6c417 --- /dev/null +++ b/openzwave/hank/hkzw-ms02-300.xml @@ -0,0 +1,95 @@ + + + + http://www.openzwave.com/device-database/0208:0012:0300 + images/hank/hkzw-ms02-200.png + https://products.z-wavealliance.org/products/2578/ + 1)Power on the device, +2) Press and hold the Z button for more than 20 seconds, +3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete. +4) The reset feature works only when the device has been included into a Z-Wave network. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + Motion sensor can be included and operated in any Z-Wave network with other Z-Wave certified devices. + +The features list: +1) Z-Wave Plus certified for wide compatibility (500 serials product). +2) Supports security 0 and security 2 protected mode with AES-128 encryption. +3) Motion sensor. +4) Tamper alarm by shock sensor. +5) The battery life is up to 1 year. +6) Low battery alarm. +7) Support firmware OTA. + + 1) Open the cover. +2) Place the device within the direct range of your Z-Wave controller. +3) Set the main controller in add mode (see the controller’s manual). +4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast. +5) Wait for the adding process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2578/HKZW-MS02-ProductManual.pdf + HKZW-MS02 + Motion Sensor + Press and hold the Z button for more than 5 seconds and release. + 1) Open the cover. +2) Place the device within the direct range of your Z-Wave controller. +3) Set the main controller remove mode (see the controller’s manual). +4) Triple click the Z-button quickly, the LED indicator should blink fast. +5) Wait for the removing process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + + Improvements based on the HKZW-M02-200 entry + Adjust description and units of configuration parameter 18 as per user manual + + + + + + + + Level 1 to 8. The higher the value, the more sensitive the PIR sensor. + 0 Disabled. + + + + Enable/disable basic set command + + + + + + Send basic set value = 255 to nodes associated with group 2 when motion alarm is triggered. Send basic set value = 0 to nodes associated with group 2 when motion alarm is canceled. + Send basic set value = 0 to nodes associated with group 2 when motion alarm is triggered. Send basic set value = 255 to nodes associated with group 2 when motion alarm is canceled. + + + + + when the value is 0, the product will not sends a vibration alarm after moving or shaking; when the value is 1, the product will sends a vibration alarm after moving or shaking + + + + + The number of seconds to delay the alarm cancellation after motion has not been detected any longer. + + + The low level from 10% to 50% + + + + + + + + + + diff --git a/openzwave/hank/hkzw-rgb01.xml b/openzwave/hank/hkzw-rgb01.xml new file mode 100644 index 00000000..c0422adb --- /dev/null +++ b/openzwave/hank/hkzw-rgb01.xml @@ -0,0 +1,96 @@ + + + http://www.openzwave.com/device-database/0208:0004:0100 + images/hank/hkzw-rgb01.png + https://products.z-wavealliance.org/products/1897/ + There are two ways to reset the RGB BULB. One is that removing +RGB BULB from the Z-Wave network, the other is that using the +configuration command class. + RGB Bulb is a smart bulb enables Z-Wave remote command and control (on/off/dim). It has over 16,000,000 colors, you can choose its color according to your favour. + To remove the RGB BULB from the Z-Wave network: +(1) Screw in the RGB BULB. +(2) Set the Z-Wave network main controller into excluding mode +(see Z-Wave controller operating manual). +(3) Toggle the wall switch off and on 3 times quickly(within 3 +and the final ending position of the wall switch must be on), +if the exclusion is successful, the RGB BULB will blink fast in +orange for less than 5 seconds and then keep on for 3 seconds. +RGB BULB will keep on warm white after the exclusion procedure +is finished. + RGB Bulb + To include RGB BULB into a Z-Wave network as a non-security device: +(1) Make sure the power supply is disconnected and the RGB BULB is +located within a direct Z-Wave network's main controller +communication range. +(2) Set the Z-Wave network main controller into learning mode +(see Z-Wave network controller operating manual). +(3) Insert the RGB BULB into a lamp-socket and then power on. +(4) Auto-inclusion will be activated. If the inclusion is successful, the +RGB BULB will blink fast in blue for less than 5 seconds and then +keep on for 3 seconds. RGB BULB will keep on in the color before it +is included into the Z-Wave network after the inclusion procedure +is finished. + +To include RGB BULB into a Z-Wave network as a security device: +(1) Screw in the RGB BULB. +(2) Set the Z-Wave network main controller into learning mode +(see Z-Wave network controller operating manual). +(3) Toggle the wall switch off and on 3 times quickly (within 3 seconds +and the final ending position of the wall switch must be on). +(4) If the inclusion is successful, the RGB BULB will blink fast in green +for less than 5 seconds and then keep on 3 seconds. RGB BULB will +keep on in the color before it is included into the Z-Wave network +after the inclusion procedure is finished. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1976/HKZW-RGB01 Manual.pdf + HKZW-RGB01 + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1897/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1976/xml + + https://products.z-wavealliance.org/products/1976/ + HKZW-RGB01 + U.S. / Canada / Mexico + + + + + Define how the RGB BULB will react after the power supply is back on. + + + + + + RGB BULB can send notifications to associated device + + + + + + Enable/disable the function of using wall switch to turn on/off RGB BULB + + + + + RGB BULB can blink or cyclic/random change color automatically at set intervals. + + + + + + + + + + + RGB BULB will exclude from the Z-Wave network with this particular command + + + + + + + + + + diff --git a/openzwave/hank/hkzw-so01-smartplug.xml b/openzwave/hank/hkzw-so01-smartplug.xml new file mode 100644 index 00000000..4d85bb13 --- /dev/null +++ b/openzwave/hank/hkzw-so01-smartplug.xml @@ -0,0 +1,99 @@ + + + http://www.openzwave.com/device-database/0208:0005:0101 + images/hank/hkzw-so01-smartplug.png + https://products.z-wavealliance.org/products/1789/ + U.S. / Canada / Mexico + Set the Z-Wave network main controller into remove mode. Triple click the Z-button, the LED will blink slowly, which indicates the inclusion is successful. + Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage.Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade. + HKZW-SO01 + Press and hold the Z-button for more than 20 seconds, the LED will blink faster and faster when the button is pressed. If holding time more than 20seconds, the LED indicator will be on for 3 seconds then it blinking slowly, which indicates the reseting is successful. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1789/HKZW-SO01_manual.pdf + Set the Z-Wave network main controller into learning mode. Short press the Z-button, the LED will keep turning on or off, which indicates the inclusion is successful. + Smart Plug + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1789/xml + + + + + + + Smart Plug keep detecting the load power, once the current exceeds 16.5a for more than 5s, smart plug's relay will turn off + + + + + Define how the plug reacts after the power supply is back on. + 0 - Smart Plug memorizes its state after a power failure. + 1 - Smart Plug does not memorize its state after a power failure. Connected device will be on after the power supply is reconnected. + 2 - Smart Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected. + + + + + + + + Smart Plug can send notifications to association device(Group Lifeline) when state of smart plug's load change + 0 - The function is disabled + 1 - Send Basic report. + 2 - Send Basic report only when Load condition is not changed by Z-WAVE Command + + + + + + + After smart plug being included into a Z-Wave network, the LED in the device will indicator the state of load. + 0 - The LED will follow the status(on/off) of its load + 1 - When the state of Switch's load changed, THe LED will follow the status(on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action. + + + + + + + Power threshold to be interpereted, when the change value of load power exceeds the setting threshold, the smart plug will send meter report to association device(Group Lifeline) + + + + + Power percentage threshold to be interpreted, when change value of the load power exceeds the setting threshold, the smart plug will send meter report to association device(Group Lifeline). + + + + + The interval of sending power report to association device(Group Lifeline). + 0 - The function is disabled. + + + + + The interval of sending power report to association device(Group Lifeline). + 0 - The function is disabled. + + + + + The interval of sending voltage report to association device(Group Lifeline). + 0 - The function is disabled. + + + + + The interval of sending electricity report to association device(Group Lifeline). + 0 - The function is disabled. + + + + + + + + + + diff --git a/openzwave/hank/hkzw-so03.xml b/openzwave/hank/hkzw-so03.xml new file mode 100644 index 00000000..657e766e --- /dev/null +++ b/openzwave/hank/hkzw-so03.xml @@ -0,0 +1,83 @@ + + + http://www.openzwave.com/device-database/0208:000A:0101 + images/hank/hkzw-so03.png + https://products.z-wavealliance.org/products/1854/ + 1) Insert the Plug into a socket. +2) Set the Z-Wave network controller into the exclusion mode (see Z-Wave controller operating manual). +3) Triple click the Z button. +4) RGB LED indicator will blink orange till the removing process is completed, than the indicator will keep orange for 3 seconds. + + U.S. / Canada / Mexico + Smart Plug + 1) Insert the Plug into a socket, +2) Press and hold the Z button for more than 20 seconds, +3) If holding time more than 20seconds, the RGB LED indicator will keep yellow for 2 seconds, which means resetting is complete. + Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + Smart plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage. +Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade . + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1854/HKZW-SO03_manual.pdf + HKZW-SO03 + 1) Connect the power supply. +2) Set the Z-Wave network main controller into inclusion mode (see Z-Wave network controller operating manual). +3) Triple click the Z-button or power up the device , RGB LED indicator should blink fast in blue. +4) Smart Plug should be recognized and included into the Z-Wave network. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1854/xml + + + + + + + + turns relay off once voltage exceeds 16.5A for over 5 secs if enabled + + + + + Recovery state for power failure + + + + + + Send notifications to associated devices + + + + + + LED Indicator Control + + + + + Minimum change in watts to report + + + Minimum percentage change to report + + + How often to report power consumption (W) in secs + + + How often to report energy usage (KWH) in secs + + + How often to report voltage (V) in secs + + + How often to report electrical current (A) in secs + + + + + + + + + diff --git a/openzwave/hank/hkzw-so05-smartplug.xml b/openzwave/hank/hkzw-so05-smartplug.xml new file mode 100644 index 00000000..b773f43b --- /dev/null +++ b/openzwave/hank/hkzw-so05-smartplug.xml @@ -0,0 +1,114 @@ + + + http://www.openzwave.com/device-database/0208:000A:0100 + images/hank/hkzw-so05-smartplug.png + https://products.z-wavealliance.org/products/1891/ + Smart Plug + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1891/HKZW-SO05 Manual.pdf + CEPT (Europe) + 1) Insert the Plug into a socket, +2) Press and hold the Z button for more than 20 seconds, +3) If holding time more than 20seconds, the RGB LED indicator will keep yellow for 2 seconds, which means resetting is completed. +Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + 1) Connect the power supply. +2) Set the Z-Wave network main controller into inclusion mode (see Z-Wave network controller operating manual). +3) Triple click the Z-button or power up the device , RGB LED indicator should blink fast in blue. +4) Smart Plug should be recognized and included into the Z-Wave network. + + HKZW-SO05 + Smart plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage, and can indicate the power level with a RGB LED. +Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade . + + 1) Insert the Plug into a socket. +2) Set the Z-Wave network controller into the exclusion mode (see Z-Wave controller operating manual). +3) Triple click the Z button. +4) RGB LED indicator will blink orange till the removing process is completed, than the indicator will keep orange for 3 seconds. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1891/xml + + + + + + + Smart Plug keep detecting the load power, once the current exceeds 10.5a for more than 5s, smart plug's relay will turn off + + + + + Define how the plug reacts after the power supply is back on. + 0 - Smart Plug memorizes its state after a power failure. + 1 - Smart Plug does not memorize its state after a power failure. Connected device will be on after the power supply is reconnected. + 2 - Smart Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected. + + + + + + + + Smart Plug can send notifications to association device(Group Lifeline) when state of smart plug's load change + 0 - The function is disabled + 1 - Send Basic report. + 2 - Send Basic report only when Load condition is not changed by Z-WAVE Command + + + + + + + After smart plug being included into a Z-Wave network, the LED in the device will indicator the state of load. + 0 - The LED will follow the status(on/off) of its load + 1 - When the state of Switch's load changed, The LED will follow the status(on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action. + + + + + + + Power threshold to be interpereted, when the change value of load power exceeds the setting threshold, the smart plug will send meter report to association device(Group Lifeline) + + + + + Power percentage threshold to be interpreted, when change value of the load power exceeds the setting threshold, the smart plug will send meter report to association device(Group Lifeline). + + + + + The interval of sending power report to association device(Group Lifeline). + 0 - The function is disabled. + + + + + The interval of sending power report to association device(Group Lifeline). + 0 - The function is disabled. + + + + + The interval of sending voltage report to association device(Group Lifeline). + 0 - The function is disabled. + + + + + The interval of sending electricity report to association device(Group Lifeline). + 0 - The function is disabled. + + + + + + + + + + diff --git a/openzwave/hank/scenecontroller1.xml b/openzwave/hank/scenecontroller1.xml new file mode 100644 index 00000000..d51df367 --- /dev/null +++ b/openzwave/hank/scenecontroller1.xml @@ -0,0 +1,63 @@ + + + http://www.openzwave.com/device-database/0208:0009:0200 + images/hank/scenecontroller1.png + https://products.z-wavealliance.org/products/1918/ + Scene Controller + CEPT (Europe) + The Scene Controller is a wireless, portable and rechargeable scene switch. It can control a Z-Wave device, such as smart plug, smart dimmer with a Z-Wave gateway. You can also activate a scene like sleep scene, movie scene and entertainment scene with it. + To remove the Scene Controller from the Z-Wave network: +(1) Insert the LIR2450 battery. +(2) Set the Z-Wave network main controller into remove mode +(see Z-Wave controller operating manual). +(3) Triple click the Z-button, if the exclusion is successful, LED +will blink in orange for less than 5 seconds and then keep on +for 3 seconds. + + + + Pressing and holding the Z-button for 20 seconds. Release the button after 20 seconds, LED will keep in yellow for 3 seconds. Scene Controller will be reset to factory defaults if you short press the button within this 3 seconds. +Using this procedure only in the event that the network primary controller is missing or otherwise inoperable. + Included as non-secure device: +1. Insert the LIR2450 battery. +2. Set the Z-Wave network main controller into learning mode( see Z-Waave network controller operating manul). +3. Triple click the Z-button. +4. If the inclusion is successful, the LED will blink in blue less than for 5 seconds and then keep on for 15 seconds. + +Included as a secure device: +1. Insert the LIR2450 battery. +2. Set the Z-Wave network main controller into learning mode( see Z-Wave network controller operating manual). +3. Pressing and holding the Z-button for 3 seconds. +4. If the inclusion is successful, the LED will blink in green less than for 5 seconds and then keep on for 15 seconds. + + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1918/HKZW-SCN01_MANUL.pdf + Pressing and holding Z-Button for 3 seconds. Led will turn to green, +which means Scene Controller has been woken up. + HKZW-SCN01 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1918/xml + + + + + + + Lock/unlock all configuration parameters + + + + + + + + + + + + + diff --git a/openzwave/hank/scenecontroller4.xml b/openzwave/hank/scenecontroller4.xml new file mode 100644 index 00000000..8a4f737a --- /dev/null +++ b/openzwave/hank/scenecontroller4.xml @@ -0,0 +1,73 @@ + + + http://www.openzwave.com/device-database/0208:000B:0201 + images/hank/scenecontroller4.png + https://products.z-wavealliance.org/products/1967/ + To remove the Scene Controller from the Z-Wave network: +(1) Insert the LIR2450 battery. +(2) Set the Z-Wave network main controller into remove mode +(see Z-Wave controller operating manual). +(3) Triple click the a button, if the exclusion is successful, LED +will blink in orange for less than 5 seconds and then keep on +for 3 seconds. + + + + Included as non-secure device: +1. Insert the LIR2450 battery. +2. Set the Z-Wave network main controller into learning mode( see Z-Waave network controller operating manul). +3. Triple click a button. +4. If the inclusion is successful, the LED will blink in blue less than for 5 seconds and then keep on for 15 seconds. + +Included as a secure device: +1. Insert the LIR2450 battery. +2. Set the Z-Wave network main controller into learning mode( see Z-Wave network controller operating manual). +3. Pressing and holding a button for 3 seconds. +4. If the inclusion is successful, the LED will blink in green less than for 5 seconds and then keep on for 15 seconds. + + + U.S. / Canada / Mexico + Scene Controller + Pressing and holding a button for 3 seconds. Led will turn to green, +which means Scene Controller has been woken up. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1968/HKZW-SCN04 Manual.pdf + Pressing and holding a button for 20 seconds. Release the button after 20 seconds, LED will keep in yellow for 3 seconds. Scene Controller will be reset to factory defaults if you short press the button within this 3 seconds. +Using this procedure only in the event that the network primary controller is missing or otherwise inoperable. + HKZW-SCN04 + The Scene Controller is a wireless, portable and rechargeable scene switch. It can control a Z-Wave device, such as smart plug, smart dimmer with a Z-Wave gateway. You can also activate a scene like sleep scene, movie scene and entertainment scene with it. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1967/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1968/xml + + https://products.z-wavealliance.org/products/1968/ + CEPT (Europe) + HKZW-SCN04 + + + + + + Lock/unlock all configuration parameters + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/heiman/HS1CA-Z.xml b/openzwave/heiman/HS1CA-Z.xml new file mode 100644 index 00000000..950c205e --- /dev/null +++ b/openzwave/heiman/HS1CA-Z.xml @@ -0,0 +1,40 @@ + + + http://www.openzwave.com/device-database/0260:1000:8005 + images/zipato/HS1CA-Z.png + https://products.z-wavealliance.org/products/2699/ + Zipato Carbon Monoxide Sensor (Z-Wave) is designed to give early warning of higher carbon monoxide level, based on Z-Wave technology. Z-Wave is a wireless communication protocol designed for remote control of appliances in residential automated homes and light commercial environments. + Press button on sensor 3 times within 1.5s, Green LED will blink 3 times within 1 second. + +If Inclusion Process is successful, Green led will turn off. + Wake up Notification is transmitted every 24 hours by default. +Wake up Notification is transmitted after Notification Report is Transmitted + CEPT (Europe) + Remove battery. +Insert battery while holding button on sensor. + +Please use this procedure only when the network primary +controller is missing or otherwise inoperable. + Press button on sensor 3 times within 1.5s, Green LED will blink 3 times within 1 second. + +If Inclusion Process is successful, Green led will turn off. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2699/hm-hs1ca-z-Smart-Carbon-Monoxide-Sensor-Z-Wave-User-Manual-1.0.pdf + Zipato Carbon Monoxide Sensor + hm-hs1ca-z.eu + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1940/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2699/xml + + + + + + + + + + + diff --git a/openzwave/heiman/HS1CG-Z.xml b/openzwave/heiman/HS1CG-Z.xml new file mode 100644 index 00000000..09858d99 --- /dev/null +++ b/openzwave/heiman/HS1CG-Z.xml @@ -0,0 +1,35 @@ + + + http://www.openzwave.com/device-database/0260:1000:8003 + images/zipato/HS1CG-Z.png + https://products.z-wavealliance.org/products/2473/ + Smart Combustible Gas Sensor in a convenient wall plug form factor for easy installation. + +Built-in audio and led notification systems for gas leakage detection events. + hm-hs1cg-z.eu + - Press the Net_Button 3 times within 1.5s +- If remove Process is successful, Green LED is Blinking 6 times, then turn on + CEPT (Europe) + -Long press Net_Button at least 10 seconds in the device. +-Device Reset Locally notification is Transmitted. +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2473/ZipatoSmartCombustibleGasSensorManual.pdf + Smart Combustible Gas Sensor + - Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second. +- If add Process is successful, Green LED will turn on. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2070/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2473/xml + + + + + + + + + + diff --git a/openzwave/heiman/HS1DS-Z.xml b/openzwave/heiman/HS1DS-Z.xml new file mode 100644 index 00000000..f6e8823a --- /dev/null +++ b/openzwave/heiman/HS1DS-Z.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/0260:0168:0168 + images/heiman/HS1DS-Z.png + https://products.z-wavealliance.org/products/3016/ + - Click [Add] icon in Z-Wave Controller . +- Press the Networking_Button 3 times within 1.5s, Green LED is Blinking 4 times within 1 second. +- If Inclusion Process is successful, Green led will turn off. + + - Wake up Notification is transmitted every 24 hours by default. +- Wake up Notification is transmitted after Notification Report is Transmitted + - Click [Remove] icon in Z-Wave Controller +- Press the Networking_Button 3 times within 1.5s +- If Exclusion Process is successful, Green led is Blinking 6 times, then turn off. + + Smart Door Sensor + Long press Networking_Button while installing batteries in the Device +-Device Reset Locally notification is Transmitted +-Green LED Turns off after 2 seconds. +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + The smart door sensor adopts Z-Wave protocol, it can detect the open or close state of door or window. when the door sensor is armed, when the door or window is opened, it will send alarm notifications to gateway immediately. + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3016/HS3DS-Z-S2documentation.pdf + HS3DS-Z + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1797/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3016/xml + + + + + + + + + + + + + diff --git a/openzwave/heiman/HS1HT-Z.xml b/openzwave/heiman/HS1HT-Z.xml new file mode 100644 index 00000000..d5bf8cda --- /dev/null +++ b/openzwave/heiman/HS1HT-Z.xml @@ -0,0 +1,39 @@ + + + http://www.openzwave.com/device-database/0260:1000:8007 + images/heiman/HS1HT-Z.png + https://products.z-wavealliance.org/products/3015/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3015/HS1HT-Z-S2documentation.pdf + - Click [Remove] icon in Z-Wave Controller. +- Press the Net_Button 3 times within 1.5s +- If Exclusion Process is successful, Green LED is Blinking 6 times, then turn off + + Smart Temperature & Humidity Sensor + - Click [Add] icon in Z-Wave Controller. +- Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second. +- If Inclusion Process is successful, Green LED will turn off. + + -Long press Net_Button at least 10 seconds in the product. +- Device Reset Locally notification is Transmitted. +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + CEPT (Europe) + Wake up Notification is transmitted every 300 seconds by default. + The smart humidity and temperature sensor adopts Z-Wave protocol. It is used to detect humidity and temperature. When the humidity or temperature exceeds the alarm thresholds, it will send alarm notifications to gateway immediately. + HS1HT-Z + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2321/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3015/xml + + + + + + + + + + + diff --git a/openzwave/heiman/HS1MS-Z.xml b/openzwave/heiman/HS1MS-Z.xml new file mode 100644 index 00000000..84c9969a --- /dev/null +++ b/openzwave/heiman/HS1MS-Z.xml @@ -0,0 +1,37 @@ + + + http://www.openzwave.com/device-database/0260:1000:8001 + images/heiman/HS1MS-Z.png + https://products.z-wavealliance.org/products/1801/ + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1801/HSIMS-Z.pdf + - Click [Remove] icon in Z-Wave PC Controller Program +- Press a Func_Button 3 times quickly in HS1MS-Z +- If Exclusion Process is successful, Green LED is Blinking 6 times, then turn off in HS1MS-Z + Smart Motion Sensor + The smart motion sensor is designed to detect motion indoors. When the smart motion sensor detects people or animals moving, it will report the information to the users mobile phone immediately. it is very easy to install, users should only paste the smart motion sensor on the wall, download the application and then connect the smart motion sensor to a smartphone via WiFi. Users will know the situation of their houses remotely. The battery life is more than 1 year and the battery is also replaceable. + - Wake up Notification is transmitted every 24 hours by default. +- Wake up Notification is transmitted after Notification Report is Transmitted + HS1MS-Z + - Click [Add] icon in Z-Wave PC Controller Program +- Press a Func_Button 3 time in HS1MS-Z (Motion Sensor), Green LED is Blinking 3 times within 1 second. +- If Inclusion Process is successful, Green LED will turn off. + Long press Func_Button while installing batteries in HS1MS-Z +- Device Reset Locally notification is Transmitted +- Please use the reset procedure only when the primary controller is missing or inoperable + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1801/xml + + + + + + + + + + + diff --git a/openzwave/heiman/HS1SA-Z.xml b/openzwave/heiman/HS1SA-Z.xml new file mode 100644 index 00000000..c9955f30 --- /dev/null +++ b/openzwave/heiman/HS1SA-Z.xml @@ -0,0 +1,42 @@ + + + http://www.openzwave.com/device-database/0260:1000:8002 + images/heiman/HS1SA-Z.png + https://products.z-wavealliance.org/products/3006/ + The Smart Smoke Alarm adopts Z-Wave protocol, when the sensor detects smoke to the set level, it will issue acoustic-optic alarm to alert the users and also send alarm notifications to gateway immediately.It's suitable to be installed in living room, office,warehouse,and etc. + - Click [Add] icon in Z-Wave Controller . +- Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second. +- If Inclusion Process is successful, Green led will turn off. + + - Click [Remove] icon in Z-Wave Controller +- Press the Net_Button 3 times within 1.5s +- If Exclusion Process is successful, Green led is Blinking 6 times, then turn off. + + - Wake up Notification is transmitted every 24 hours by default. +- Wake up Notification is transmitted after Notification Report is Transmitted + --Long press Net_Button while installing batteries in the product. +- Device Reset Locally notification is Transmitted. +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + HS1SA-Z + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3006/HS1SA-Z S2-documentation_3.pdf + Smart Smoke Alarm + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1936/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2710/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3006/xml + + + + + + + + + + + diff --git a/openzwave/heiman/HS1WL-Z.xml b/openzwave/heiman/HS1WL-Z.xml new file mode 100644 index 00000000..58a5fd5b --- /dev/null +++ b/openzwave/heiman/HS1WL-Z.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/0260:1000:8004 + images/heiman/HS1WL-Z.png + https://products.z-wavealliance.org/products/3027/ + The Smart Water Leakage Sensor can protect your house from potential water damage.It can be placed near plumbing,sinks,aquariums,pumps,refrigerators,dishwashers,toilets,basements,washing machines,water heaters,and garages. + - Wake up Notification is transmitted every 24 hours by default. +- Wake up Notification is transmitted after Notification Report is Transmitted + - Click [Add] icon in Z-Wave Controller . +- Press the Networking_Button 3 times within 1.5s, Green LED is Blinking 4 times within 1 second. +- If Inclusion Process is successful, Green led will turn off. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3027/HS3WL-Z-S2documentation.pdf + HS3WL-Z + - Click [Remove] icon in Z-Wave Controller +- Press the Networking_Button 3 times within 1.5s +- If Exclusion Process is successful, Green led is Blinking 6 times, then turn off. + + -Long press Networking_Button while installing batteries in the Device +-Device Reset Locally notification is Transmitted +-Green LED Turns off after 2 seconds. +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + CEPT (Europe) + Smart Water Leakage Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2322/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2709/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3027/xml + + + + + + + + + + + + + diff --git a/openzwave/heiman/HS2SK-Z.xml b/openzwave/heiman/HS2SK-Z.xml new file mode 100644 index 00000000..0ef7886a --- /dev/null +++ b/openzwave/heiman/HS2SK-Z.xml @@ -0,0 +1,40 @@ + + + http://www.openzwave.com/device-database/0260:1000:8006 + images/heiman/HS2SK-Z.png + https://products.z-wavealliance.org/products/3017/ + CEPT (Europe) + Smart Metering Plug + -Long press SW_Button at least 10 seconds in HS2SK-Z. +- Device Reset Locally notification is Transmitted. +-Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + The smart metering plug, adopts flame-retardant engineering material and Z-Wave protocol. it can be controlled by APP remotely. It also supports power metering and timing switch, and the function of power, voltage, current overload protection. + HS2SK-Z + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3017/HS2SK-Z-S2documentation.pdf + - Click [Remove] icon in Z-Wave Controller. +- Press the SW_Button 3 times within 1.5s +- If remove Process is successful, Green LED is Blinking 6 times, then turn off. + + - Click [Add] icon in Z-Wave Controller. +- Press the SW_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second. +- If add Process is successful, Green LED will turn off. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1941/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2315/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3017/xml + + https://products.z-wavealliance.org/products/2315/ + HS2SK-Z + CEPT (Europe) + + + + + + + + diff --git a/openzwave/heiman/HS2WD-Z.xml b/openzwave/heiman/HS2WD-Z.xml new file mode 100644 index 00000000..53bf22e3 --- /dev/null +++ b/openzwave/heiman/HS2WD-Z.xml @@ -0,0 +1,12 @@ + + + + + + + + + + diff --git a/openzwave/heltun/he-ft01.xml b/openzwave/heltun/he-ft01.xml new file mode 100644 index 00000000..be17472a --- /dev/null +++ b/openzwave/heltun/he-ft01.xml @@ -0,0 +1,405 @@ + + + + Fan Coil Thermostat HE-FT01 + This is advanced programmable Thermostat for Heating/Cooling Systems + http://www.openzwave.com/device-database/0344:0002:0004 + https://www.heltun.com/ + https://www.heltun.com/support + images/heltun/he-ft01.png + https://products.z-wavealliance.org/products/3717 + U.S. / Canada / Mexico + CEPT (Europe) + Australia / New Zealand + Russia + Israel + China + South Korea + Japan + Hong Kong + India + HE-FT01 + + Metadata for HELTUN FanCoil Thermostat + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 0 + true + + + + + + + + + + + + + + + + + + + + + + + + + + + + Time correction by controller + + + + + + + Time format 0=24hour, 1=12hour (AM/PM) + + + + + + + Manually set week day + + + + + + + + + + + + Manually set time hour + + + + + Maually set time minute + + + + + Degree Mode 0=C, 1=F + + + + + + + Air Temperature Calibration in degree, x10 + + + + + Temperature Hysteresis in degree, x10 + + + + + Display auto-brightness control + + + + + + + Display manual brightness level + + + + + Touch buttons sensitivity. 5=Super sensitive. 50=lowest sensitivity. + + + + + This Parameter defines which Operating Mode the HE-FT01 reverts to if the Basic Set command is received. + + + + + + + + + + + + + + + Sensors consecutive reporting interval, minutes + + + + + Consumption meter consecutive reporting interval, minutes + + + + + Temperature difference to send to controller, value X 10 + Note: values between 0 ... 5 are not used. + + + + + Humidity difference to send to controller, % + Note: values between 0 ... 2 are not used. + + + + + Light sensor values difference to send to controller, % + Note: values between 0 ... 10 are not used. + + + + + Power of the Relay 1 load in W + + + + + Power of the Relay 2 load in W + + + + + Power of the Relay 3 load in W + + + + + Power of the Relay 4 load in W + + + + + Power of the Relay 5 load in W + + + + + This parameter determines the Climate Mode (Heating or Cooling) to which HE-FT01 will switch when the TIME operating mode is selected. + If the value = 1 the thermostat will go to Heating and Cooling mode, if value = 2 the thermostat goes to Heating mode, if the value = 3 the thermostat goes to Cooling Mode. + + + + + + + + Morning start time. Format: HHMM. e.g.08:00 should be sent as 0800 + + + + + Day start time. Format: HHMM. + + + + + Evening start time. Format: HHMM. + + + + + Night start time. Format: HHMM. + + + + + Monday morning temperature, value x10 + + + + + Monday day temperature, value x10 + + + + + Monday evening temperature, value x10 + + + + + Monday night temperature, value x10 + + + + + Tuesday morning temperature, value x10 + + + + + Tuesday day temperature, value x10 + + + + + Tuesday evening temperature, value x10 + + + + + Tuesday night temperature, value x10 + + + + + Wednesday morning temperature, value x10 + + + + + Wednesday day temperature, value x10 + + + + + Wednesday evening temperature, value x10 + + + + + Wednesday night temperature, value x10 + + + + + Thursday morning temperature, value x10 + + + + + Thursday day temperature, value x10 + + + + + Thursday evening temperature, value x10 + + + + + Thursday night temperature, value x10 + + + + + Friday morning temperature, value x10 + + + + + Friday day temperature, value x10 + + + + + Friday evening temperature, value x10 + + + + + Friday night temperature, value x10 + + + + + Saturday morning temperature, value x10 + + + + + Saturday day temperature, value x10 + + + + + Saturday evening temperature, value x10 + + + + + Saturday night temperature, value x10 + + + + + Sunday morning temperature, value x10 + + + + + Sunday day temperature, value x10 + + + + + Sunday evening temperature, value x10 + + + + + Sunday night temperature, value x10 + + + + + + + + + + + + + + diff --git a/openzwave/heltun/he-ht01.xml b/openzwave/heltun/he-ht01.xml new file mode 100644 index 00000000..c9b2325c --- /dev/null +++ b/openzwave/heltun/he-ht01.xml @@ -0,0 +1,427 @@ + + + Heating Thermostat HE-HT01 + This is advanced programmable Thermostat for Heating Systems + http://www.openzwave.com/device-database/0344:0001:0004 + https://www.heltun.com/ + https://www.heltun.com/support + images/heltun/he-ht01.png + https://products.z-wavealliance.org/products/3681 + U.S. / Canada / Mexico + CEPT (Europe) + Australia / New Zealand + Russia + Israel + China + South Korea + Japan + Hong Kong + India + HE-HT01 + + Metadata for HELTUN Heating Thermostat + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 0 + true + + + + + + + Floor Sensor Resistance, kohm + + + + + External input mode. The thermostat can be connected to an external device (like security system) dry output contacts and control the thermostat operating modes depending on the contacts state. + If parameter value is 0 no action will be take (the input state is ignored by the thermostat logic). If parameter value is 1 the thermostat will be switched to the operating mode selected in + Parameter 3 if the S1 was short-circuited. The thermostat will go back to previous mode as soon as the S1 is open. If parameter value is 2 the thermostat will be switched to the operating + mode selected in Parameter 3 if the S1 was short-circuited. But the thermostat will not undertake any action if the S1 is open again. + + + + + + + + Mode number for S1 input action. This parameter allows selecting which operating mode the thermostat should go to if the S1 input is short-circuited with Sx or LINE wire of the mains electricity. + 1=COM, 2=TIME, 3=DRY, 4=ECO, 5=VAC, 6=MAN mode with IDLE(off) state, 7=MAN mode with HEATING(on) state. + + + + + + + + + + + + Source Sensor: 1=A, 2=AF, 3=F, 4=FA, 5=P, 6=PA, 7=PF. + A=Air sensor, + AF - Air sensor + Floor sensor, + F - Floor sensor, + FA - Floor sensor +Air sensor, + P - Power regulator, + PA - Power regulator + Air sensor, + PF - Power regulator + Floor sensor + + + + + + + + + + + + Power Regulation ON time, min + + + + + Power Regulation OFF time, min + + + + + Dry Time, min + + + + + Mode to switch after Dry mode operation completion + + + + + + + + + + + Time correction by controller + + + + + Time format 0=24hour, 1=12hour (AM/PM) + + + + + + + Manually set week day + + + + + Manually set time hour + + + + + Maually set time minute + + + + + Air Temperature Minimum in degree, value X 10, e.g. 22.5°C=225 + + + + + Air Temperature Maximum in degree, x10 + + + + + Floor Temperature Minimum in degree, x10 + + + + + Floor Temperature Maximum in degree, x10 + + + + + Degree Mode 0=C, 1=F + + + + + + + Air Temperature Calibration in degree, x10 + + + + + Floor Temperature Calibration in degree, x10 + + + + + Temperature Hysteresis in degree, x10 + + + + + Display auto-brightness control + + + + + + + Display manual brightness level + + + + + Touch buttons sensitivity. 5=Super sensitive. 50=lowest sensitivity. + + + + + Mode to switch to on Basic Set Action command receive + + + + + + + + + + + Sensors consecutive reporting interval, minutes + + + + + Consumption meter consecutive reporting interval, minutes + + + + + Temperature difference to send to controller, value X 10 + Note: values between 0 ... 5 are not used. + + + + + Humidity difference to send to controller, % + Note: values between 0 ... 2 are not used. + + + + + Light sensor values difference to send to controller, % + Note: values between 0 ... 10 are not used. + + + + + Morning start time. Format: HHMM. e.g.08:00 should be sent as 0800 + + + + + Day start time. Format: HHMM. + + + + + Evening start time. Format: HHMM. + + + + + Night start time. Format: HHMM. + + + + + Monday morning temperature, value x10 + + + + + Monday day temperature, value x10 + + + + + Monday evening temperature, value x10 + + + + + Monday night temperature, value x10 + + + + + Tuesday morning temperature, value x10 + + + + + Tuesday day temperature, value x10 + + + + + Tuesday evening temperature, value x10 + + + + + Tuesday night temperature, value x10 + + + + + Wednesday morning temperature, value x10 + + + + + Wednesday day temperature, value x10 + + + + + Wednesday evening temperature, value x10 + + + + + Wednesday night temperature, value x10 + + + + + Thursday morning temperature, value x10 + + + + + Thursday day temperature, value x10 + + + + + Thursday evening temperature, value x10 + + + + + Thursday night temperature, value x10 + + + + + Friday morning temperature, value x10 + + + + + Friday day temperature, value x10 + + + + + Friday evening temperature, value x10 + + + + + Friday night temperature, value x10 + + + + + Saturday morning temperature, value x10 + + + + + Saturday day temperature, value x10 + + + + + Saturday evening temperature, value x10 + + + + + Saturday night temperature, value x10 + + + + + Sunday morning temperature, value x10 + + + + + Sunday day temperature, value x10 + + + + + Sunday evening temperature, value x10 + + + + + Sunday night temperature, value x10 + + + + + + + + + + diff --git a/openzwave/heltun/he-zw-sw-5a-1.xml b/openzwave/heltun/he-zw-sw-5a-1.xml new file mode 100644 index 00000000..5e39b27e --- /dev/null +++ b/openzwave/heltun/he-zw-sw-5a-1.xml @@ -0,0 +1,368 @@ + + + + + + + + + Backlight 1 control source + + + + + + + + Backlight 2 control source + + + + + + + + Backlight 3 control source + + + + + + + + Backlight 4 control source + + + + + + + + Backlight 5 control source + + + + + + + + + Relay 1 control source + + + + + + + + + + + Relay 2 control source + + + + + + + + + + + Relay 3 control source + + + + + + + + + + + Relay 4 control source + + + + + + + + + + + Relay 5 control source + + + + + + + + + + + + Click control mode for touch button 1 + + + + + + + + + + + + Click control mode for touch button 2 + + + + + + + + + + + + Click control mode for touch button 3 + + + + + + + + + + + + Click control mode for touch button 4 + + + + + + + + + + + + Click control mode for touch button 5 + + + + + + + + + + + + + Hold control mode for touch button 1 + + + + + + + + + Hold control mode for touch button 2 + + + + + + + + + Hold control mode for touch button 3 + + + + + + + + + Hold control mode for touch button 4 + + + + + + + + + Hold control mode for touch button 5 + + + + + + + + + + Timer mode duration for button 1 + + + + + Timer mode duration for button 2 + + + + + Timer mode duration for button 3 + + + + + Timer mode duration for button 4 + + + + + Timer mode duration for button 5 + + + + + + Power of the Relay 1 load in W + + + + + Power of the Relay 2 load in W + + + + + Power of the Relay 3 load in W + + + + + Power of the Relay 4 load in W + + + + + Power of the Relay 5 load in W + + + + + + Red colour backlight brightness + + + + + + + + + + Blue colour backlight brightness + + + + + + + + + + Red colour auto brightness level 1 max lumens + + + + + + Red colour auto brightness level 2 max lumens + + + + + + Blue colour auto brightness level 1 max lumens + + + + + + Blue colour auto brightness level 2 max lumens + + + + + + Active state backlight colour + + + + + + + + Temperature sensor calibration + + + + + + Temperature difference to send to controller, value X 10 + + + + + + Touch buttons sensitivity. 10=Supper sensitive. 60=lowest sensitivity. + + + + + + If Fibaro Home Center Lite or Fibaro Home Center 2 is used as a gateway for correct + communication of the devices set this parameter 1. For other gateways choose 0. + Factory default value: 0. + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/heltun/he-zw-therm-fc1.xml b/openzwave/heltun/he-zw-therm-fc1.xml new file mode 100644 index 00000000..9ecf7c84 --- /dev/null +++ b/openzwave/heltun/he-zw-therm-fc1.xml @@ -0,0 +1,382 @@ + + + + + + + + + 0 + true + + + + + + + + + + + + + + + + + + + + + Degree Mode 0=C, 1=F + + + + + + + + Air Temperature Calibration in degree x10 + + + + + + Temperature Hysteresis in degree, x10 + + + + + + Temperature difference to send to controller, value x10 + + + + + + Time correction by controller + + + + + + + + Time format 0=24hour, 1=12hour (AM/PM) + + + + + + + + Manually set week day + + + + + + + + + + + + + Manually set time hour + + + + + + Maually set time minute + + + + + + The brightness level can be selected in the active state from values 1 (lowest brightness) to 4 + (highest brightness) but the level cannot be lower than the level of brightness for the inactive + state (param 11). + + + + + + This parameter defines the brightness level of the display in the inactive state. The level can + be selected from values 1 to 4 but the level cannot be higher than the level of brightness for + the active state (param 10). + + + + + + Auto LCD brightness control + + + + + + + + Auto brightness level 1 max lumens + + + + + + Auto brightness level 2 max lumens + + + + + + Auto brightness level 3 max lumens + + + + + + If Fibaro Home Center Lite or Fibaro Home Center 2 is used as a gateway for correct + communication of the devices set this parameter 1. For other gateways choose 0. + Factory default value: 0. + + + + + + + + Touch buttons sensitivity. 20=Super sensitive. 70=lowest sensitivity. + + + + + + Power of the Relay 1 load in W + + + + + Power of the Relay 2 load in W + + + + + Power of the Relay 3 load in W + + + + + Power of the Relay 4 load in W + + + + + Power of the Relay 5 load in W + + + + + + Morning start time. Format: HHMM. e.g.08:00 should be sent as 0800 + + + + + + Day start time. Format: HHMM. + + + + + + Evening start time. Format: HHMM. + + + + + + Night start time. Format: HHMM. + + + + + + Monday morning temperature, value x10 + + + + + + Monday day temperature, value x10 + + + + + + Monday evening temperature, value x10 + + + + + + Monday night temperature, value x10 + + + + + + Tuesday morning temperature, value x10 + + + + + + Tuesday day temperature, value x10 + + + + + + Tuesday evening temperature, value x10 + + + + + + Tuesday night temperature, value x10 + + + + + + Wednesday morning temperature, value x10 + + + + + + Wednesday day temperature, value x10 + + + + + + Wednesday evening temperature, value x10 + + + + + + Wednesday night temperature, value x10 + + + + + + Thursday morning temperature, value x10 + + + + + + Thursday day temperature, value x10 + + + + + + Thursday evening temperature, value x10 + + + + + + Thursday night temperature, value x10 + + + + + + Friday morning temperature, value x10 + + + + + + Friday day temperature, value x10 + + + + + + Friday evening temperature, value x10 + + + + + + Friday night temperature, value x10 + + + + + + Saturday morning temperature, value x10 + + + + + + Saturday day temperature, value x10 + + + + + + Saturday evening temperature, value x10 + + + + + + Saturday night temperature, value x10 + + + + + + Sunday morning temperature, value x10 + + + + + + Sunday day temperature, value x10 + + + + + + Sunday evening temperature, value x10 + + + + + + Sunday night temperature, value x10 + + + + + + + + + + + + + + diff --git a/openzwave/heltun/he-zw-therm-fl2.xml b/openzwave/heltun/he-zw-therm-fl2.xml new file mode 100644 index 00000000..c95c3c7a --- /dev/null +++ b/openzwave/heltun/he-zw-therm-fl2.xml @@ -0,0 +1,371 @@ + + + + + + 0 + true + + + + + + + + + + + + + + + + + + + + + + + + + + + + Degree Mode 0=C, 1=F + + + + + + + External input mode. The thermostat can be connected to an external device (like security system) dry output contacts and control the thermostat operating modes depending on the contacts state. If parameter value is 0 no action will be take (the input state is ignored by the thermostat logic). If parameter value is 1 the thermostat will be switched to the operating mode selected in Parameter 3 if the output was short-circuited. The thermostat will go back to previous mode as soon as the input is open. If parameter value is 2 the thermostat will be switched to the operating mode selected in Parameter 3 if the output was short-circuited. But the thermostat will not undertake any action if the input is open again. + + + + + + + + Mode number for EXT input action. This parameter allows selecting which operating mode the thermostat should go to if the external input is short-circuited. 1=COM, 2=TIME, 3=DRY, 4=ECO, 5=VAC, 6=MAN. Note: When thermostat goes to MAN mode it will be in IDLE state till HEATING key is not pressed manually. + + + + + + + + + + + Source Sensor: 1=A, 2=AF, 3=F, 4=FA, 5=P, 6=PA, 7=PF. A=Air sensor, AF - Air sensor + Floor sensor, F - Floor sensor, FA - Floor sensor +Air sensor, P - Power regulator, PA - Power regulator + Air sensor, PF - Power regulator + Floor sensor + + + + + + + + + + + + Power Regulation ON time, min + + + + + Power Regulation OFF time, min + + + + + Dry Time, min + + + + + Time correction by controller + + + + + Time format 0=24hour, 1=12hour (AM/PM) + + + + + + + Manually set week day + + + + + Manually set time hour + + + + + Maually set time minute + + + + + Air Temperature Minimum in degree, value x10, e.g. 22.5=225 + + + + + Air Temperature Maximum in degree, x10 + + + + + Floor Temperature Minimum in degree, x10 + + + + + Floor Temperature Maximum in degree, x10 + + + + + Floor Sensor Resistance, kohm + + + + + Air Temperature Calibration in degree x10 + + + + + Floor Temperature Calibration in degree x10 + + + + + Temperature Hysteresis in degree, x10 + + + + + Temperature difference to send to controller, value x10 + + + + + Active display brightness level. Must be greater than or equal param 23 + + + + + Inactive display brightness level. Must be less than or equal param 22 + + + + + Auto LCD brightness control + + + + + Auto brightness level 1 max lumens + + + + + Auto brightness level 2 max lumens + + + + + Auto brightness level 3 max lumens + + + + + Basic Set Action + + + + + + + + + + + Touch buttons sensitivity. 20=Super sensitive. 70=lowest sensitivity. + + + + + Morning start time. Format: HHMM. e.g.08:00 should be sent as 0800 + + + + + Day start time. Format: HHMM. + + + + + Evening start time. Format: HHMM. + + + + + Night start time. Format: HHMM. + + + + + Monday morning temperature, value x10 + + + + + Monday day temperature, value x10 + + + + + Monday evening temperature, value x10 + + + + + Monday night temperature, value x10 + + + + + Tuesday morning temperature, value x10 + + + + + Tuesday day temperature, value x10 + + + + + Tuesday evening temperature, value x10 + + + + + Tuesday night temperature, value x10 + + + + + Wednesday morning temperature, value x10 + + + + + Wednesday day temperature, value x10 + + + + + Wednesday evening temperature, value x10 + + + + + Wednesday night temperature, value x10 + + + + + Thursday morning temperature, value x10 + + + + + Thursday day temperature, value x10 + + + + + Thursday evening temperature, value x10 + + + + + Thursday night temperature, value x10 + + + + + Friday morning temperature, value x10 + + + + + Friday day temperature, value x10 + + + + + Friday evening temperature, value x10 + + + + + Friday night temperature, value x10 + + + + + Saturday morning temperature, value x10 + + + + + Saturday day temperature, value x10 + + + + + Saturday evening temperature, value x10 + + + + + Saturday night temperature, value x10 + + + + + Sunday morning temperature, value x10 + + + + + Sunday day temperature, value x10 + + + + + Sunday evening temperature, value x10 + + + + + Sunday night temperature, value x10 + + + + + + + + + + diff --git a/openzwave/homeseer/ezmotionplus.xml b/openzwave/homeseer/ezmotionplus.xml new file mode 100644 index 00000000..2d5bffbb --- /dev/null +++ b/openzwave/homeseer/ezmotionplus.xml @@ -0,0 +1,134 @@ + + + + + + Sensitivity sets the amount of motion required for the device to + detect motion. A higher value makes it more sensitive and a + lower value makes it less sensitive. Note that values above 200 + are not recommended when the device is battery operated. + Recommended values: + 10 = Pet Immune. + 100 = Medium sensitivity for hallways. + 200(default) = Highly sensitive for rooms where people are sitting still. + + + + + On Time sets the number of minutes that the lights stay on when + motion has not been detected. + A value of 0 On Time is a special mode where the lights are + constantly sent a command to turn them on whenever motion is + detected. The device will NOT turn the lights off in this mode. + Note that this mode will significantly shorten battery life. + Recommended values: + 5 min for hallways. + 20 min for an office environment. + 60 min for a library or other room where someone may be sitting + still for a long time. + This may be inaccurate, but default for Homeseer HSM100 may actually be 3 minutes, instead of 20? + + + + + LED ON/OFF turns the LED on or off. A slight improvement in + battery life is obtained by turning the LED off. Setting LED + ON/OFF to zero will turn the LED off and 255 turns it on. + Default is On (255). + + + + + + + Light Threshold is the percentage of light in the room above + which the lights will not be turned on. Light Threshold is often + used in room with a lot of natural daylight. Setting Light + Threshold to a value of 50% will cause the device to not turn the + lights on when the natural light in the room is already at the 50% + value. This feature only prevents the lights from coming on when + motion is first detected and the light level in the room is already + above Light Threshold. It will not turn the lights off when the + amount of natural light in the room increases. It will + automatically turn on the lights in a room that has motion in it + and that the amount of natural light has dropped below Light + Threshold. + A value of 100% turns off this feature (default). + Recommended values: + Usually a value between 40% and 60% will prevent the lights + from coming on in a reasonably well light room and will turn + them on as it is getting dark. Some experimentation is required + with each room to determine the proper setting. + + + + + Setting Stay Awake to a non-zero value will cause the device to + always be awake. NOTE: this mode should NOT be used when + the device is battery powered! Batteries will only last a few days + in this mode. + Stay Awake is NOT set to the factory default (0) when the device + is Excluded (reset) from the Z-Wave network. + Setting Stay Awake to a non-zero value will cause the Z-Wave + Listening Bit to be set. The device will become a routing node in + the Z-Wave Mesh-Network when the Listening Bit is set. + To properly have the device included in the routing tables, set + Stay Awake to a non-zero value, then reset the device (Exclude + from the network), then add it back to the network. The new + routing information will be used now that the listening bit is set. + Defaults to 0. + + + + + On Value is the value sent by the Z-Wave BASIC_SET + command when motion is detected. + A value of 0 will turn the lights off (not recommended). + A value between 1 and 100 will set the dim level to between 1% + and 100%. + A value of 255 will turn the light on (default). + NB! According to the manual, the value should not be set between 101-254 (inclusive). + + + + + TempAdj is a twos-complement number that is used to adjust the temperature reading to make it more accurate. + The value programmed is in tenths of degree Fahrenheit. + The temperature reading can be adjusted up to +12.7F to -12.8F. + A value of 1 will adjust the temperature reading by +0.1F. + A value of -1 will adjust the temperature by -0.1F. + A value of 123 will adjust the temperature by +12.3F. + TempAdj is NOT changed when Excluded (reset) from the Z- Wave network. + + + + + Bit mask for disabling the sending of sensor reports at each WakeUp interval. + Bit 0=Temperature + Bit 1=Luminance + Bit 2=Battery level + Setting the respective but to a 1 will disable the sending of the sensor report at each WakeUp interval. + A value of 7 will disable all sensors. + Note that the controller can still request a sensor report but the sensor will not be sent automatically. + Disabling sensors will improve battery life. + + + + + + + true + + + + + + true + + + + + + + + diff --git a/openzwave/homeseer/hs-ds100plus.xml b/openzwave/homeseer/hs-ds100plus.xml new file mode 100644 index 00000000..e2f816f2 --- /dev/null +++ b/openzwave/homeseer/hs-ds100plus.xml @@ -0,0 +1,58 @@ + + + Door/Window Sensor + Door/Window Sensor is a wireless reed sensor powered by AAA battery. It is used for detecting the opening or closing of doors, windows. It can communicate with an associated Z-Wave device, such as Siren, Smart Switch, etc. + http://www.openzwave.com/device-database/000C:0008:0201 + https://homeseer.com/sensors/ + https://homeseer.com/support-home/ + images/homeseer/hs-ds100plus.png + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2958/DoorWindowSensorEngineeringSpecification.pdf + + 1. Insert the AAA battery. +2. Set the Z-Wave network main controller into learning mode. +3. Triple or single short press the Z-button. +4. If the add for inclusion is successful, the LED will blink less than 5 seconds and then keep on 3 seconds. Otherwise, the LED will blink 5 seconds and then turn off, in which case you need to repeat the process from step 2. + + 1. Insert the AAA battery. +2. Pressing and holding the Z button for more than 20 seconds, +3. Led will keep on until the Z-Button is released, and it will reset to factory default when the button is released. + +Using this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + 1. Insert the AAA battery. +2. Set the Z-Wave network main controller into learning mode. +3. Triple clicking the Z-button. +4. If the remove for exclusion, the LED will turn off within 1 second. Otherwise, the LED will blink 5 seconds and then turn off, in which case you need to repeat the process from step 2. + + https://products.z-wavealliance.org/products/2958/ + U.S. / Canada / Mexico + HS-DS100+ + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/2958/XML + + + + + + Door/Window Sensor can reverse its value of BASIC SET when the magnet is triggered. + + + + + + This parameter defines a battery level as the “low battery”. + + + + + + + + + + + + + + + diff --git a/openzwave/homeseer/hs-fc200plus.xml b/openzwave/homeseer/hs-fc200plus.xml new file mode 100644 index 00000000..a0a00563 --- /dev/null +++ b/openzwave/homeseer/hs-fc200plus.xml @@ -0,0 +1,140 @@ + + + http://www.openzwave.com/device-database/000C:0001:0203 + images/homeseer/hs-fc200plus.png + https://products.z-wavealliance.org/products/2957/ + HS-FC200+ is a Z-Wave controllable wired fan controller for use with 3-speed or 4-speed ceiling fans. It has a vertical row of LED’s that indicate the fan speed level. + +• Works with 3-speed or 4-speed fans only +• 4 segment LED dim level indicator +• Remotely or manually turns ON or OFF, or fan speed level +• Fits standard wall plates (wall plate not included) +• Works with any certified gateway supporting Z-Wave + Inclusion: Add the device into your network by a Z-Wave certified controller. HS-FC200+ supports the latest S2 security offered by Z-Wave certified controllers. If your controller supports S2, please refer to the user guide of the controller for detailed instructions on adding devices to the network. You should be able to add HS-FC200+ into your network using the unique QR code or the DSK 5 digit pin located on the product or packaging. In addition, the device can be added or removed using the following 2-step procedure: + +1. Put your Z-Wave controller into Inclusion mode. Consult your controller manual if you're unsure how to do this. +2. Tap the paddle of your new HomeSeer switch to begin the inclusion process. This will take a few moments to complete. + HS-FC200+ + Exclusion: Remove the device from your network by a Z-Wave certified controller. HS-FC200+ supports the latest S2 security offered by Z-Wave certified controllers. If your controller supports S2, please refer to the user guide of the controller for detailed instructions on removing devices from the network. You should be able to remove HS-FC200+ into your network using the unique QR code or the DSK 5 digit pin located on the product or packaging. In addition, the device can be added or removed using the following 2-step procedure: + +1. Put your Z-Wave controller into Exclusion mode. Consult your controller manual if you're unsure how to do this. +2. Tap the paddle of your new HomeSeer switch to begin the Exclusion process. This will take a few moments to complete. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2957/HS FC200 Manual Market Cert v1.pdf + U.S. / Canada / Mexico + Z-Wave RGB Fan Controller + To be used only in the event that the network primary controller is lost or otherwise inoperable. + +(1) Turn switch on by tapping the top of the paddle once. +(2) Quickly ap top of the paddle 3 times. +(3) Quickly tap bottom of paddle 3 times. +(4) If the LED turns off then on again, switch is reset. If not, repeat manual rest. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2957/xml + + + + + + + + Sets bottom LED operation (in normal mode) + + + + + Sets paddle's load orientation + + + + + Sets fan type + + + + + Sets LED indicator mode of operation + + + + + Sets the Normal mode LED color + + + + + + + + + + Sets the Status mode LED 1 (bottom) color + + + + + + + + + + + Sets the Status mode LED 2 color + + + + + + + + + + + Sets the Status mode LED 3 color + + + + + + + + + + + Sets the Status mode LED 4 color + + + + + + + + + + + Sets the blink frequency for all LEDs in Status mode. Possible values: 0, 1-255 + 0 = No blink + 1 = 100ms ON then 100ms OFF + + + + Sets LEDs 1-4 to blink in Status mode. Bitmask defines specific LEDs to enable for blinking. Note: this decimal value is derived from a hex code calculation based on the following: + Bit 0 = LED 1 + Bit 1 = LED 2 + Bit 2 = LED 3 + Bit 3 = LED 4 + IE: value of 1 = first LED, 8 = LED 4 + + + + + + + + + + diff --git a/openzwave/homeseer/hs-fls100plus.xml b/openzwave/homeseer/hs-fls100plus.xml new file mode 100644 index 00000000..ed39cd06 --- /dev/null +++ b/openzwave/homeseer/hs-fls100plus.xml @@ -0,0 +1,54 @@ + + + http://www.openzwave.com/device-database/000C:000B:0201 + images/homeseer/hs-fls100plus.png + https://products.z-wavealliance.org/products/2947/ + HS-FLS100+ is a Z-Wave enabled outdoor motion sensor that may be used for a variety of applications. + +• Use as a stand alone outdoor motion sensor and/or LUX sensor. +• Use as a replacement sensor for a motion-activated floodlight unit. In this configuration, it can control floodlight loads when motion is sensed or when commands are received from the central controller. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2947/HS-FLS100-user-manual2b-A501112779R.pdf + Z-Wave auto inclusion. +Or manual inclusion : put the Z-Wave controller into inclusion mode, press the Link button 3 times within 1.5 seconds to put the unit into inclusion mode. + U.S. / Canada / Mexico + Put the Z-Wave Controller into exclusion mode. Press the Link button 3 times within 1.5 seconds to put the unit into exclusion mode. + HomeSeer HS-FLS100+ Z-Wave Plus Floodlight Sensor + HS-FLS100+ + The product reset is to operate only when the primary controller is missing or inoperable. Press the Link button 3 times within 1.5 seconds to put the unit into exclusion mode.Within 1 second of step 1, press the Link button again and hold until LED is off (about 5 seconds). + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2947/xml + + + + + + Period to send Trigger Off command after PIR is triggered. + + + + When the lux level falls below this threshold and the PIR gets triggered, the unit emits a Basic Set Command (Value=0xFF) and turns on its floodlight. This overwrites the Lux level set by the Lux knob. + + Setting = 0: Never turn ON light when PIR triggered + Setting = 30~200: Turn ON light when lux is below configured threshold. + Setting = 255: Always turn ON light when PIR triggered + + If the level is set to 0, the unit will not turn on its floodlight. The sensor will only send a notification report to the controller. + + + + sets the interval of periodic lux level report to the controller + + + + + + + + + + + + + + + diff --git a/openzwave/homeseer/hs-fs100plus.xml b/openzwave/homeseer/hs-fs100plus.xml new file mode 100644 index 00000000..18f62bdf --- /dev/null +++ b/openzwave/homeseer/hs-fs100plus.xml @@ -0,0 +1,44 @@ + + + + + + + + Operation with the Light Sensor cable on USB power. + + + + + + Beep interval when on battery power and on USB power during the time water is detected. + + + + + + Temperature report interval on USB power, seconds. + + + The buzzer may be disabled when detecting water on line power or battery, the default value is set to enabled. + + + + + + Set delay to avoid continuous notifications when detecting flashing LEDs. Flex Sensor will not send notification until flashing LED status changes. Note: Use only when detecting flashing LEDs. + + + + + + + + + + diff --git a/openzwave/homeseer/hs-ls100plus.xml b/openzwave/homeseer/hs-ls100plus.xml new file mode 100644 index 00000000..068947be --- /dev/null +++ b/openzwave/homeseer/hs-ls100plus.xml @@ -0,0 +1,123 @@ + + + http://www.openzwave.com/device-database/000C:000A:0201 + images/homeseer/hs-ls100plus.png + https://products.z-wavealliance.org/products/2735/ + Press and hold the Z button for more than 5 seconds and release. + 1) Open the cover. +2) Place the device within the direct range of your Z-Wave controller. +3) Set the main controller in add mode (see the controller’s manual). +4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast. +5) Wait for the adding process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + + LEAK SENSOR + LEAK SENSOR is capable of both detecting leaks and floods and when the level of water gets too low in pool or tank, LEAK SENSOR can work with your z-wave network to prevent emergencies such as burst water boiler to leaking air conditioners. With Z-Wave, the scope to save money is endless. + +The features list: +1) Z-Wave Plus certified for wide compatibility (500 serials product). +2) Security 0 and security 2 framework implemented with AES-128 encryption. +3) Contains an extension water detecting probe. +4) Temperature measurement. +5) Vibration sensor. +6) The battery life is up to 1 year. +7) Low battery alert + + 1) Power on the device +2) Press and hold the Z button for more than 20 seconds, +3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete. +4) The reset feature works only when the device has been included into a Z-Wave network. + +Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2735/User Manual revised 1211.pdf + 1) Open the cover. +2) Place the device within the direct range of your Z-Wave controller. +3) Set the main controller remove mode (see the controller’s manual). +4) Triple click the Z-button quickly, the LED indicator should blink fast. +5) Wait for the removing process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + U.S. / Canada / Mexico + HS-LS100+ + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2735/xml + + + + + + + + Enable / disable the basic set command send to group 2 + + + + + + Define BASIC SET VALUE to nodes associated with group 2 when flooding alarm is triggered and is canceled. + + + + + + Leak report interval, minutes. O to disable. + + + + When the value is Disable, the product will not sends a vibration alarm after moving or shaking. + When the value is Enable, the product will sends a vibration alarm after moving or shaking. + + + + + + Temperature report interval, minutes. O to disable. + + + + Set the high temperature alarm trigger value. + Available: -670 to 2570 (-67.0 to 257.0 F) + Default: 1040 (104.0 F) + + + + + Set the low temperature alarm trigger value. + Available: -670 to 2570 (-67.0 to 257.0 F) + Default: 320 (32.0 F) + + + + + When the value is Disable, the product will not alarm when being triggered. + When the value is Enable, the product will alarm when being triggered. + + + + + + Low battery reporting threshold, %. + + + + + + + + + + + + + + + diff --git a/openzwave/homeseer/hs-ms100plus.xml b/openzwave/homeseer/hs-ms100plus.xml new file mode 100644 index 00000000..4c2b882a --- /dev/null +++ b/openzwave/homeseer/hs-ms100plus.xml @@ -0,0 +1,106 @@ + + + http://www.openzwave.com/device-database/000C:0009:0201 + images/homeseer/hs-ms100plus.png + https://products.z-wavealliance.org/products/2729/ + 1)Power on the device, +2) Press and hold the Z button for more than 20 seconds, +3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete. +4) The reset feature works only when the device has been included into a Z-Wave network. + +Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + + + U.S. / Canada / Mexico + 1) Open the cover. +2) Place the device within the direct range of your Z-Wave controller. +3) Set the main controller in add mode (see the controller’s manual). +4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast. +5) Wait for the adding process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + + HS-MS100+ + 1) Open the cover. +2) Place the device within the direct range of your Z-Wave controller. +3) Set the main controller remove mode (see the controller’s manual). +4) Triple click the Z-button quickly, the LED indicator should blink fast. +5) Wait for the removing process to end. +6) Successful adding will be confirmed by the Z-Wave controller’s message. + + Motion sensor can be included and operated in any Z-Wave network with other Z-Wave certified devices. + +The features list: +1) Z-Wave Plus certified for wide compatibility (500 serials product). +2) Supports security 0 and security 2 protected mode with AES-128 encryption. +3) Motion sensor. +4) Tamper alarm by shock sensor. +5) The battery life is up to 1 year. +6) Low battery alarm. +7) Support firmware OTA. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2729/User Manual for motion sensor-revised .pdf + Press and hold the Z button for more than 5 seconds and release. + Motion Sensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2729/xml + + + + + + + Motion Sensor Sensitivity. 0 - Sensor is OFF, 8 - Max sensitivity. + + + + + + + + + + + + Enable / disable the basic set command send to group 2 + + + + + + Define BASIC SET VALUE to nodes associated with group 2 when motion alarm is triggered and is canceled. + + + + + + when the value is Disable, the product will not sends a vibration alarm after moving or shaking; + when the value is Enable, the product will sends a vibration alarm after moving or shaking + + + + + Motion Timeout Interval, seconds + + + Low battery reporting threshold, % + + + + + + + + + + + + + + + + diff --git a/openzwave/homeseer/hs-wd100plus.xml b/openzwave/homeseer/hs-wd100plus.xml new file mode 100644 index 00000000..b751a26c --- /dev/null +++ b/openzwave/homeseer/hs-wd100plus.xml @@ -0,0 +1,73 @@ + + + http://www.openzwave.com/device-database/000C:3034:4447 + images/homeseer/hs-wd100plus.png + https://products.z-wavealliance.org/products/2874/ + Please use this procedure only in the event that the network primary controller is lost or otherwise inoperable. + +All Configuration Parameters can all be restored to their factory default settings by using your primary controller to delete/reset the device. +To manually reset, tap the ON button twice quickly and then tap the OFF button twice quickly. Repeat the procedure to restore the settings to the factory default. + + + Z-Wave Wall Dimmer + U.S. / Canada / Mexico + - Works with incandescent and dimmable florescent (CFL) and LED lighting +- ON/OFF/DIM status LED indicator +- Fits into standard single or multiple gang junction box +- Keypad can be replaced manually to match color with other wall switches +- Over-The-Air firmware upgrade available with compatible gateway, Z-Wave static controller, or PC and software +- Internal resettable fuse to protect from surge current +- Manual reset capability +- Supports Central Scene +- Supports S2 Security + + 1. Turn the connected lights ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF. +2. Add(Include) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. +3. Normally, the sequence is as follows: when the inclusion process is prompted by your primary controller, single click and release the rocker switch to ON or OFF position. The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. + HS-WD100+ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2874/HS-WD100-Manual-6a.pdf + 1. Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF. +2. Delete(Exclude) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. +3. Normally, the sequence is as follows: when the exclusion process is prompted by your primary controller, single click and release the rocker switch. The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1730/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1731/xml + Apply PR #1546 from kaburke + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2563/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2874/xml + Added compatibility parameters to ensure correct dimming level is reported + + + + + + true + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON if the switch was installed upside down. + + + + + Indicates how much each level dims/brightens as a portion of the whole range when set remotely. + + + Indicates the time duration of each level when set remotely. + + + Indicates how much each level dims/brightens as a portion of the whole range when set locally. + + + Indicates the time duration of each level when set locally. + + + + + + + + + diff --git a/openzwave/homeseer/hs-wd200plus.xml b/openzwave/homeseer/hs-wd200plus.xml new file mode 100644 index 00000000..4c73e3c0 --- /dev/null +++ b/openzwave/homeseer/hs-wd200plus.xml @@ -0,0 +1,169 @@ + + + http://www.openzwave.com/device-database/000C:3036:4447 + images/homeseer/hs-wd200plus.png + https://products.z-wavealliance.org/products/2676/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2676/HS-WD200-Manual-4.pdf + 1. Turn the connected lights ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF. +2. Add(Include) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. +3. Normally, the sequence is as follows: when the inclusion process is prompted by your primary controller, single click and release the rocker switch to ON or OFF position. The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. + Please use this procedure only in the event that the network primary controller is lost or otherwise inoperable. + +All Configuration Parameters can all be restored to their factory default settings by using your primary controller to delete/reset the device. +To manually reset, tap the ON button twice quickly and then tap the OFF button twice quickly. Repeat the procedure to restore the settings to the factory default. + + + U.S. / Canada / Mexico + - Works with incandescent and dimmable florescent (CFL) or most LED lighting +- ON/OFF status and location LED indicator +- Includes Z-Wave controllable RGB LED indicators +- Fits into standard single or multiple gang junction box +- Keypad can be replaced manually to match color with other wall switches +- Over-The-Air firmware upgrade available with compatible gateway, Z-Wave static controller, or PC and software +- Internal resettable fuse to protect from surge current +- Manual reset capability +- Support Central Scene +- Includes Controllable RGB LED Indicators + + Z-Wave Wall Dimmer with RGB LED + 1. Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF. +2. Delete(Exclude) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. +3. Normally, the sequence is as follows: when the exclusion process is prompted by your primary controller, single click and release the rocker switch. The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. + HS-WD200+ + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2676/xml + + + + + + Sets bottom LED operation (in normal mode) + + + + + Change the top of the switch to OFF and the bottom of the switch to ON if the switch was installed upside down. + + + + + Ramp rate in seconds. 0 is no delay + + + Ramp rate in seconds. 0 is no delay + + + Normal mode (load status) or status mode (custom status) + + + + + Sets the Normal mode LED color + + + + + + + + + + Sets the Status mode LED color + + + + + + + + + + + Sets the Status mode LED color + + + + + + + + + + + Sets the Status mode LED color + + + + + + + + + + + Sets the Status mode LED color + + + + + + + + + + + Sets the Status mode LED color + + + + + + + + + + + Sets the Status mode LED color + + + + + + + + + + + Sets the Status mode LED color + + + + + + + + + + + 100ms blink intervals. 0 is off + + + Bitmask defines specific LEDs to enable for blinking: Note: this decimal value is derived from a hex code calculation based on the following: + Bit 0 = led 1 + Bit 1 = led 2 + Bit 2 = led 3 + Bit 3 = led 4 + Bit 4 = led 5 + Bit 5 = led 6 + Bit 6 = led 7 + IE: value of 1 = first LED, 64 = led 7 + + + + + + + + + + diff --git a/openzwave/homeseer/hs-ws100plus.xml b/openzwave/homeseer/hs-ws100plus.xml new file mode 100644 index 00000000..335544df --- /dev/null +++ b/openzwave/homeseer/hs-ws100plus.xml @@ -0,0 +1,55 @@ + + + http://www.openzwave.com/device-database/000C:3033:4447 + images/homeseer/hs-ws100plus.png + https://products.z-wavealliance.org/products/2894/ + HS-WS100+ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2894/HS-WS100-Manual-v6.pdf + HS-WS100+ In Wall On/Off Switch +- Works with incandescent, florescent (CFL), or most LED lighting and appliances +- ON/OFF status and location LED indicator +- Fits into standard single or multiple gang junction box +- Keypad can be replaced manually to match color with other wall switches +- Over-The-Air firmware upgrade available with compatible gateway, Z-Wave static controller, or PC and software. +- Internal resettable fuse to protect from surge current +- Manual reset capability +- Support Central Scene + U.S. / Canada / Mexico + 1. Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF. +2. Add(Include) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. +3. Normally, the sequence is as follows: when the inclusion process is prompted by your primary controller, single click and release the rocker switch to ON or OFF position. The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. + 1. Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF. +2. Delete(Exclude) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. Normally, the sequence is as follows: when the exclusion process is prompted by your primary controller, single click and release the rocker switch. The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. + Please use this procedure only in the event that the network primary controller is lost or otherwise inoperable. + +All Configuration Parameters can all be restored to their factory +default settings by using your primary controller to delete/reset +the device. To manually reset, tap the ON button twice quickly and then tap the OFF button twice quickly. Repeat the procedure to restore the settings to the factory default. + + Z-Wave Wall Switch + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2554/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2894/xml + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON if the switch was installed upside down. + + + + + Set the LED policy: on if the load is on, off if the load is on, or off all the time + + + + + + + + + + + + diff --git a/openzwave/homeseer/hs-ws200plus.xml b/openzwave/homeseer/hs-ws200plus.xml new file mode 100644 index 00000000..1d379867 --- /dev/null +++ b/openzwave/homeseer/hs-ws200plus.xml @@ -0,0 +1,86 @@ + + + http://www.openzwave.com/device-database/000C:3035:4447 + images/homeseer/hs-ws200plus.png + https://products.z-wavealliance.org/products/2675/ + 1. Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF. +2. Delete(Exclude) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. Normally, the sequence is as follows: when the exclusion process is prompted by your primary controller, single click and release the rocker switch. The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2675/HS-WS200-Manual-v4.pdf + Please use this procedure only in the event that the network primary controller is lost or otherwise inoperable. + +All Configuration Parameters can all be restored to their factory +default settings by using your primary controller to delete/reset +the device. To manually reset, tap the ON button twice quickly and then tap the OFF button twice quickly. Repeat the procedure to restore the settings to the factory default. + + HS-WS200+ In Wall On/Off Switch +- Works with incandescent, florescent (CFL), or most LED lighting and appliances +- ON/OFF status and location LED indicator +- Includes Z-Wave controllable RGB LED indicator +- Fits into standard single or multiple gang junction box +- Keypad can be replaced manually to match color with other wall switches +- Over-The-Air firmware upgrade available with compatible gateway, Z-Wave static controller, or PC and software. +- Internal resettable fuse to protect from surge current +- Manual reset capability +- Support Central Scene + Z-Wave Wall Switch with RGB LED + HS-WS200+ + 1. Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF. +2. Add(Include) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. +3. Normally, the sequence is as follows: when the inclusion process is prompted by your primary controller, single click and release the rocker switch to ON or OFF position. The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2675/xml + + + + + + Sets bottom LED operation (in normal mode) + + + + + Change the top of the switch to OFF and the bottom of the switch to ON if the switch was installed upside down. + + + + + Normal mode (load status) or status mode (custom status) + + + + + Sets the Normal mode LED color + + + + + + + + + + Sets the Status mode LED color + + + + + + + + + + + Sets the blink frequency of the LED + 0 = No Blink + 1 = 100ms ON then 100ms OFF + + + + + + + + + + diff --git a/openzwave/homeseer/hsm100.xml b/openzwave/homeseer/hsm100.xml new file mode 100644 index 00000000..d0053091 --- /dev/null +++ b/openzwave/homeseer/hsm100.xml @@ -0,0 +1,119 @@ + + + + + + Sensitivity sets the amount of motion required for the device to + detect motion. A higher value makes it more sensitive and a + lower value makes it less sensitive. Note that values above 200 + are not recommended when the device is battery operated. + Recommended values: + 10 = Pet Immune. + 100 = Medium sensitivity for hallways. + 200(default) = Highly sensitive for rooms where people are sitting still. + + + + + On Time sets the number of minutes that the lights stay on when + motion has not been detected. + A value of 0 On Time is a special mode where the lights are + constantly sent a command to turn them on whenever motion is + detected. The device will NOT turn the lights off in this mode. + Note that this mode will significantly shorten battery life. + Recommended values: + 5 min for hallways. + 20 min for an office environment. + 60 min for a library or other room where someone may be sitting + still for a long time. + This may be inaccurate, but default for Homeseer HSM100 may actually be 3 minutes, instead of 20? + + + + + LED ON/OFF turns the LED on or off. A slight improvement in + battery life is obtained by turning the LED off. Setting LED + ON/OFF to zero will turn the LED off and 255 turns it on. + Default is On (255). + + + + + + + Light Threshold is the percentage of light in the room above + which the lights will not be turned on. Light Threshold is often + used in room with a lot of natural daylight. Setting Light + Threshold to a value of 50% will cause the device to not turn the + lights on when the natural light in the room is already at the 50% + value. This feature only prevents the lights from coming on when + motion is first detected and the light level in the room is already + above Light Threshold. It will not turn the lights off when the + amount of natural light in the room increases. It will + automatically turn on the lights in a room that has motion in it + and that the amount of natural light has dropped below Light + Threshold. + A value of 100% turns off this feature (default). + Recommended values: + Usually a value between 40% and 60% will prevent the lights + from coming on in a reasonably well light room and will turn + them on as it is getting dark. Some experimentation is required + with each room to determine the proper setting. + + + + + Setting Stay Awake to a non-zero value will cause the device to + always be awake. NOTE: this mode should NOT be used when + the device is battery powered! Batteries will only last a few days + in this mode. + Stay Awake is NOT set to the factory default (0) when the device + is Excluded (reset) from the Z-Wave network. + Setting Stay Awake to a non-zero value will cause the Z-Wave + Listening Bit to be set. The device will become a routing node in + the Z-Wave Mesh-Network when the Listening Bit is set. + To properly have the device included in the routing tables, set + Stay Awake to a non-zero value, then reset the device (Exclude + from the network), then add it back to the network. The new + routing information will be used now that the listening bit is set. + Defaults to 0. + + + + + On Value is the value sent by the Z-Wave BASIC_SET + command when motion is detected. + A value of 0 will turn the lights off (not recommended). + A value between 1 and 100 will set the dim level to between 1% + and 100%. + A value of 255 will turn the light on (default). + NB! According to the manual, the value should not be set between 101-254 (inclusive). + + + + + TempAdj is a twos-complement number that is used to adjust the temperature reading to make it more accurate. + The value programmed is in tenths of degree Fahrenheit. + The temperature reading can be adjusted up to +12.7F to -12.8F. + A value of 1 will adjust the temperature reading by +0.1F. + A value of -1 will adjust the temperature by -0.1F. + A value of 123 will adjust the temperature by +12.3F. + TempAdj is NOT changed when Excluded (reset) from the Z- Wave network. + + + + + + + + + true + + + + + + + + + diff --git a/openzwave/homeseer/hsm200.xml b/openzwave/homeseer/hsm200.xml new file mode 100644 index 00000000..e6a07969 --- /dev/null +++ b/openzwave/homeseer/hsm200.xml @@ -0,0 +1,95 @@ + + + http://www.openzwave.com/device-database/001E:0001:0004 + images/homeseer/hsm200.png + https://products.z-wavealliance.org/products/2794/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2794/EZMultiPliOwnerManual.pdf + EZmultiPli + When EZMultiPli is first plugged into the wall outlet, the LED should blink an aqua color. This indicates that it is not currently joined (or paired) to a Z-Wave network. If the LED is blinking white each time motion is detected, then it is already joined to a Z-Wave network. If the LED is blinking white you will need to exclude it from the other Z-Wave network before attempting to join a new one. +Follow the procedure of the Z-Wave primary controller to begin the exclusion process. Once the primary controller is ready to receive the exclusion command, press and release the push button on the side of EZMultiPli. The primary controller should give an indication that the reset process has completed. EZMultiPlis LED will blink aqua when it is ready to be added to a Z-Wave network. + SmartStart or press and release the button on the side. +LED blinks slowly light blue when not included. +Once included, the LED blinks white when motion is detected for about 5 minutes to test the motion detection area. + Factory Reset +If the exclusion process above is not working or the controller EZMultiPli was originally joined to is lost or not available, the following process can be used to factory reset EZMultiPli. + +Press and continue to hold the push button in for about 60 seconds. The LED will blink blue faster and faster and then shift to yellow and continue to blink faster and faster. Once the LED goes out, EZMultiPli is reset to the factory defaults and will blink aqua indicating it is ready to be added to a Z-Wave network. + + EZMultiPli + Notify caregivers when a loved one does not get up at their usual time or gets up multiple times during the night. Easily installed in a kitchen, bathroom, bedroom or hallway - just plug it in! The wide angle motion sensor detects motion when placed at floor level in a normal wall outlet or at counter height in a kitchen or bath. Never needs batteries! + +Receive an email or text when motion is detected or the temperature is dangerously low while you are away. Turn on lights and sirens automatically. + +Save energy by automatically turning off lights in unoccupied rooms or hallways. + +Set the color LED night light to inform you that your garage door is open, there is a severe weather alert or any indicator you can imagine! + +Operates as a Z-Wave range extender utilizing fifth generation Z-Wave technology to enhance the reliability and speed of every device on a Z-Wave network. + +Version 2.0 firmware adds AES-128 security S2 and SmartStart + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1124/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1254/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2794/xml + + http://store.homeseer.com/store/X-P1882.aspx + + + + + + Parameter #0 is undocumented: let us know if you know what it does! + Attributes (type, units, min and max) are wild guesses, except default value. + + + + + On Time sets the number of minutes that the lights stay on when + motion has not been detected. + A value of 0 On Time is a special mode where the lights are + constantly sent a command to turn them on whenever motion is + detected. The device will NOT turn the lights off in this mode. + Note that this mode will significantly shorten battery life. + Recommended values: + 5 min for hallways. + 20 min for an office environment. + 60 min for a library or other room where someone may be sitting + still for a long time. + This may be inaccurate, but default for Homeseer HSM100 may actually be 3 minutes, instead of 20? + + + + + OnLevel is the value sent by the Z-Wave BASIC_SET command to all Association Group 2 nodes when motion is detected. + A value of 0 will turn the lights off (not recommended). + A value between 1 and 99 will set the dim level to between 1% and 99% (99% is full on). + A value of -1 will turn the light on which depends on the device but most will set the dim level to the last dim setting. + + + + + LiteMinutes. A Luminance report is sent to the system controller every LiteMin minutes. + A value of zero turns this mode off. Luminance values can still be obtained at any time by the home control application in this mode. + + + + + TempMinutes. A Temperature report is sent to the controller every TempMin minutes. + A value of zero turns this mode off. Temperature values can still be obtained at any time by polling the status of the temperature sensor. + + + + + TempAdj. TempAdj is a twos-complement number that is used to adjust the temperature reading to make it more accurate. The value is in tenths of degree Fahrenheit. The temperature reading can be adjusted by +12.7F to -12.8F. A value of 1 will adjust the temperature reading by +0.1F. A value of -1 will adjust the temperature by -0.1F. A value of 123 will adjust the temperature by +12.3F. + + + + + + + + + + + diff --git a/openzwave/homeseer/ztroller.xml b/openzwave/homeseer/ztroller.xml new file mode 100644 index 00000000..0eb824f7 --- /dev/null +++ b/openzwave/homeseer/ztroller.xml @@ -0,0 +1,6 @@ + + + + + + diff --git a/openzwave/honeywell/2681-plugin-dimmer.xml b/openzwave/honeywell/2681-plugin-dimmer.xml new file mode 100644 index 00000000..5c43c56e --- /dev/null +++ b/openzwave/honeywell/2681-plugin-dimmer.xml @@ -0,0 +1,102 @@ + + + http://www.openzwave.com/device-database/0039:3038:5044 + images/honeywell/2681-plugin-dimmer.png + https://products.z-wavealliance.org/products/2681/ + U.S. / Canada / Mexico + Plug-in Smart Dimmer, Single Plug + 1. Follow the instructions for your Z-Wave certified controller to add +the smart dimmer to the Z-Wave network. +2. Once the controller is ready to add your smart dimmer, single +press and release the manual/program button on the smart +dimmer to add it in the network. +Please reference the controller/gateway’s manual for instructions. + 39336/ZW3104 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2681/39336-HQSG_v1.pdf + To return your dimmer to factory defaults: +1. If plugged in, unplug the dimmer from the receptacle. +2. Press and hold the top button for at least 3 seconds while you +plug the dimmer into a receptacle. +Note: This should only be used in the event your networks’ primary +controller is missing or otherwise inoperable. + Transform any home into a smart home with the Honeywell Z-Wave Plug-In Smart Dimmer. The Smart Dimmer enables wireless control of on/off and dim functions for standard incandescent table and floor lamps, as well as dimmable fluorescent, LED and CFL fixtures and more! Use the dimmer control to customize the lighting output and create the perfect ambiance for any room. The space-saving horizontal module plugs into a standard wall receptacle without blocking the second outlet or obstructing placement of furniture. The Dimmer provides one Z-Wave enabled outlet for the lamp you would like to control. Take control of your home lighting with Honeywell Z-Wave Smart Lighting Controls! + 1. Follow the instructions for your Z-Wave certified controller to +remove a device from the Z-Wave network. +2. Once the controller is ready to remove your device, press and +release the manual/program button on the smart dimmer to +remove it from the network. + + Copied from 28617/ZW3104 GE Plug-in Dimmer by Justin Hammond - Justin@dynam.ac + + + + + + + true + + + + + + + Sets when the LED on the switch is lit. + + + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + + + + + + diff --git a/openzwave/honeywell/3830-zw3107.xml b/openzwave/honeywell/3830-zw3107.xml new file mode 100644 index 00000000..f1bfeff9 --- /dev/null +++ b/openzwave/honeywell/3830-zw3107.xml @@ -0,0 +1,70 @@ + + + Plug-in Dimmer (Dual Plug Simultaneous Control) + Transform any home into a smart home with the Honeywell Z-Wave Smart Lighting Control Lamp Module with Dimmer Control. The lamp module enables wireless control of on/off and dim functions for standard incandescent table and floor lamps, as well as dimmable fluorescent, LED and CFL fixtures and more! Use the dimmer control to customize the lighting output and create the perfect ambiance for any room. The space-saving horizontal module plugs into a standard wall receptacle without blocking the second outlet or obstructing placement of furniture. It provides a Z-Wave enabled outlet for the lamp you would like to control and one always-on, simultaneous control AC outlet for other electrical appliances. Take control of your home lighting with Honeywell Z-Wave Smart Controls! + http://www.openzwave.com/device-database/0039:3033:5044 + images/honeywell/3830-zw3107.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3830/39446-HQSG_v4.pdf + Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network. Once the controller is ready to add your device, press and release the manual/program button on the smart dimmer. Repeat as necessary to add the dimmer to the network. + Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network. Once the controller is ready to remove your device, press and release the manual/program button on the smart dimmer to remove it from the network. + If plugged in, unplug the dimmer from the receptacle. Press and hold the top button, plug the device in and continue to hold for at least 3 seconds. + https://products.z-wavealliance.org/products/3830 + U.S. / Canada / Mexico + 39446 / ZW3107 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/3830/xml + + + + + + + true + + + + + + + + Adjusts when the indicator LED is turned ON, OFF, or disabled + + + + + + Adjusts when the indicator LED is turned ON, OFF, or disabled + + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + + + + + + + + + + + diff --git a/openzwave/honeywell/39348-ZW4005.xml b/openzwave/honeywell/39348-ZW4005.xml new file mode 100644 index 00000000..86749a7f --- /dev/null +++ b/openzwave/honeywell/39348-ZW4005.xml @@ -0,0 +1,46 @@ + + + + images/honeywell/39348-ZW4005.png + https://products.z-wavealliance.org/products/2689/ + 39348 / ZW4005 + 1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network. +2. Once the controller is ready to include your device, press and release the top or bottom of the wireless smart switch(rocker) to include it in the network. +3. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. + Quickly press ON (Top) button 3 times then immediately press the OFF (Bottom) button 3 times. The LED will flash ON/OFF 5 times when completed successfully. +Note: Please use this reset procedure only when the primary controller is missing or inoperable. + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to exclude your device, press and release the top button of the wireless smart switch (rocker) to exclude it from the network. + In-Wall Smart Switch + U.S. / Canada / Mexico + + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2689/39348-HQSG_v1.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/2689/XML + Correct Product Pic Entry + + + + + + Sets when the LED on the switch is lit. + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + + + + + + + + diff --git a/openzwave/honeywell/39348-zw4008.xml b/openzwave/honeywell/39348-zw4008.xml new file mode 100644 index 00000000..c34178e5 --- /dev/null +++ b/openzwave/honeywell/39348-zw4008.xml @@ -0,0 +1,49 @@ + + + + + images/honeywell/39348-ZW4008.png + https://products.z-wavealliance.org/products/3599/ + 39348 / ZW4008 + 1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network. +2. Once the controller is ready to add your device, press and release the top or bottom of the wireless smart switch (rocker) to add it in the network. + +If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the back of the box, or the QR code label on the product. + Quickly press ON (top) button 3 times, then, immediately press the OFF (bottom) button 3 times. The LED will flash ON/OFF 5 times when completed successfully. +Note: This should only be used in the event your network’s primary controller is missing or otherwise inoperable. + 1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network. +2. Once the controller is ready to remove your device, press and release the top or bottom of the wireless smart switch (rocker) to remove it from the network. + In-Wall Smart Switch + U.S. / Canada / Mexico + In-Wall Smart Switch with QuickFit and SimpleWire enhancements. Revolutionary QuickFit design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. This reduced size coupled with the elimination of heat taps provides a better fit in older style boxes and multi-gang configurations. SimpleWire technology allows line and load to automatically be configured with auto-sensing line-load terminals. All of this is coupled with Z-Wave S2 and Smart Start allows for effortless installation while being safer than ever! + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3599/39348%20Binder.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/3599/xml + + + + + + Sets when the LED on the switch is lit. + + + + + + + 0 (default) - Press any button on the device +1 - Press 2 times ON button and then 2 times OFF button, LED will flash 5 times if done successful + + + + + + + + + + + + + diff --git a/openzwave/honeywell/39349-ZW1002.xml b/openzwave/honeywell/39349-ZW1002.xml new file mode 100644 index 00000000..165a806d --- /dev/null +++ b/openzwave/honeywell/39349-ZW1002.xml @@ -0,0 +1,38 @@ + + + + images/honeywell/39349-ZW1002.png + https://products.z-wavealliance.org/products/2690 + 39349 / ZW1002 + 1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network. 2. Once the controller is ready to add your device, press and release the program button to add it in the network. + Quickly press the button three (3) times, then press and hold the button for at least three (3) seconds. The LED will blink five (5) times to confirm. + 1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network. 2. Once the controller is ready to remove your device, press and release the manual/program button to remove it from the network. + In-Wall Tamper Resistant Outlet + U.S. / Canada / Mexico + The Honeywell Z-Wave Tamper Resistant Outlet enables wireless control of on/off functions from the Z-Wave controlled outlet + https://byjasco.com/products/ge-z-wave-plus-wall-tamper-resistant-smart-outlet + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2690/39349_HQSG_1.pdf + https://byjasco.com/support + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/2690/XML + + + + + + Sets when the LED on the outlet is lit. + + + + + + + + + + + + + + diff --git a/openzwave/honeywell/39351-ZW3005.xml b/openzwave/honeywell/39351-ZW3005.xml new file mode 100644 index 00000000..8929ac7a --- /dev/null +++ b/openzwave/honeywell/39351-ZW3005.xml @@ -0,0 +1,74 @@ + + + http://www.openzwave.com/device-database/0039:3038:4944 + images/honeywell/39351-ZW3005.png + https://products.z-wavealliance.org/products/2724/ + 39351 / ZW3005 + 1. Follow the instructions for your Z-Wave certified controller to +include a device to the Z-Wave network. +2. Once the controller is ready to add your device, +press and release the top or bottom of the wireless smart +switch (rocker) to add it in the network. +Please reference the controller’s manual for instructions. + Quickly press ON (Top) button three (3) times then immediately +press the OFF (Bottom) button three (3) times. The LED will flash +ON/OFF 5 times when completed successfully. +NOTE: This should only be used in the event your network’s +primary controller is missing or otherwise inoperable. + 1. Follow the instructions for your Z-Wave certified controller to +remove a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press +and release the top or bottom of the wireless smart dimmer +(rocker) to remove it from the network. + In-Wall Dimmer + U.S. / Canada / Mexico + Transform any home into a smart home with the Honeywell In-Wall Dimmer. The In-Wall Dimmer can easily replace any standard in-wall switch and remotely controls a light in your home. Your home will be equipped with ultimate flexibility with the Honeywell Z-Wave Dimmer, capable of being used by itself or with up to four add-on switches. Screw terminal installation provides improved space efficiency when replacing existing switches and the integrated LED indicator light allows you to easily locate the switch in a dark room. The Honeywell Z-Wave In-Wall Dimmer is compatible with any Z-Wave certified gateway, providing access to many popular home automation systems. Take control of your home lighting with Honeywell Z-Wave Smart Controls! + + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2724/39351-QSG-v1-para.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2724/xml + + + + + + Sets when the LED on the switch is lit. + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + + + + + + + + + diff --git a/openzwave/honeywell/39351-ZW3010.xml b/openzwave/honeywell/39351-ZW3010.xml new file mode 100644 index 00000000..a738a208 --- /dev/null +++ b/openzwave/honeywell/39351-ZW3010.xml @@ -0,0 +1,74 @@ + + + + + http://www.openzwave.com/device-database/0039:3235:4944 + images/honeywell/39351-ZW3005.png + https://products.z-wavealliance.org/products/3600/ + In-Wall Smart Dimmer + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3600/39351%20Binder.pdf + U.S. / Canada / Mexico + Quickly press ON (Top) button three (3) times then immediately +press the OFF (Bottom) button three (3) times. The LED will flash +ON/OFF 5 times when completed successfully. +NOTE: This should only be used in the event your network’s +primary controller is missing or otherwise inoperable. + 1. Follow the instructions for your Z-Wave certified controller to +include a device to the Z-Wave network. +2. Once the controller is ready to add your device, +press and release the top or bottom of the wireless smart +switch (rocker) to add it in the network. +Please reference the controller’s manual for instructions. + In-Wall Smart Dimmer with QuickFit and SimpleWire enhancements. Revolutionary QuickFit design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. This reduced size coupled with the elimination of heat taps provides a better fit in older style boxes and multi-gang configurations. SimpleWire technology allows line and load to automatically be configured with auto-sensing line-load terminals. All of this is coupled with Z-Wave S2 and Smart Start allows for effortless installation while being safer than ever! + 39351/ZW3010 + 1. Follow the instructions for your Z-Wave certified controller to +remove a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press +and release the top or bottom of the wireless smart dimmer +(rocker) to remove it from the network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3600/xml + + + + + Adjust the LED status to default, invert, always OFF or always ON + + + + + + + Adjust the speed at which the ramps to a specific value other than 0 and FF + + + + + Turn your dimmer into an On/Off switch with switch mode + + + + + Never accidentally remove a device during with alternate exclusion + + + + + Set the minimum dimmer threshold + + + Set the brightness threshold + + + Set the default brightness level that the dimmer will turn on when being controlled manually + + + + + + + + + + + diff --git a/openzwave/honeywell/39357-ZW3004.xml b/openzwave/honeywell/39357-ZW3004.xml new file mode 100644 index 00000000..6ff16ac7 --- /dev/null +++ b/openzwave/honeywell/39357-ZW3004.xml @@ -0,0 +1,56 @@ + + + + In-Wall Smart Toggle Dimmer + Transform any home into a smart home with the Honeywell Z-Wave In-Wall Toggle Dimmer. The dimmer enables wireless control of on/off and dim functions of hard-wired dimmable LED/CFL and incandescent lighting. The dimmer replaces your current light switch, uses your existing wiring, and provides Z-Wave wireless and in-wall control of overhead lighting. Use the dimmer feature to customize the lighting output and create the perfect ambiance for any room. Providing ultimate flexibility, the In-Wall Dimmer allows you to operate the switch by itself or easily integrate the switch three-way or four-way wiring configurations by adding the Honeywell Add-On Switch. Single Pole wiring configuration controls the light from one location. Three-way wiring configuration controls the light from two separate locations. Four-way wiring configuration controls the light from three separate locations. The Honeywell Add-On Switch is required for three-way or four-way installations. Take control of your home lighting with Honeywell Z-Wave Smart Controls! + http://www.openzwave.com/device-database/0039:3130:4944 + https://byjasco.com/honeywell-z-wave-plus-wall-smart-dimmer-0 + images/honeywell/39357-ZW3004.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2727/39357-QSG-v1-para.pdf + 1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network. 2. Once the controller is ready to add your device, press up and release on the toggle to add it in the network + 1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network. 2. Once the controller is ready to remove your device, press up and release on the toggle to add it in the network + Quickly press UP button three (3) times then immediately press the DOWN button three (3) times. + https://products.z-wavealliance.org/products/2727 + U.S. / Canada / Mexico + 39357 / ZW3004 + + Initial creation + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + Indicates how many levels the dimmer will change for each dimming step. + + + This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. + + + + + + + + + + + + + diff --git a/openzwave/honeywell/39358-ZW4002.xml b/openzwave/honeywell/39358-ZW4002.xml new file mode 100644 index 00000000..3af81788 --- /dev/null +++ b/openzwave/honeywell/39358-ZW4002.xml @@ -0,0 +1,48 @@ + + + http://www.openzwave.com/device-database/0039:3131:4944 + images/honeywell/39358-ZW4002.png + https://products.z-wavealliance.org/products/2725/ + 39358 / ZW4002 + 1. Follow the instructions for your Z-Wave certified controller to +include a device to the Z-Wave network. +2. Once the controller is ready to add your device, +press and release the top or bottom of the wireless smart +switch (rocker) to add it in the network. +Please reference the controller’s manual for instructions. + Quickly press ON (Top) button three (3) times then immediately +press the OFF (Bottom) button three (3) times. The LED will flash +ON/OFF 5 times when completed successfully. +NOTE: This should only be used in the event your network’s +primary controller is missing or otherwise inoperable. + 1. Follow the instructions for your Z-Wave certified controller to +remove a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press +and release the top or bottom of the wireless smart dimmer +(rocker) to remove it from the network. + In-Wall Fan Control + U.S. / Canada / Mexico + Transform any home into a smart home with the Honeywell Z-Wave Fan Control. The in-wall fan control easily replaces any standard in-wall switch remotely controls a ceiling fan in your home and features a three-speed control system. Your home will be equipped with ultimate flexibility with the Honeywell Z-Wave Fan Control, capable of being used by itself or with up to four Honeywell add-on switches. Screw terminal installation provides improved space efficiency when replacing existing switches and the integrated LED indicator light allows you to easily locate the switch in a dark room. The Honeywell Z-Wave Fan Control is compatible with any Z-Wave certified gateway, providing access to many popular home automation systems. Take control of your home lighting with Honeywell Z-Wave Smart Controls! + + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2725/39358-HQSG-v1-para.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2725/xml + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. + + + + + + + + + + + + + diff --git a/openzwave/honeywell/39449-ZW4106.xml b/openzwave/honeywell/39449-ZW4106.xml new file mode 100644 index 00000000..8f329dda --- /dev/null +++ b/openzwave/honeywell/39449-ZW4106.xml @@ -0,0 +1,52 @@ + + + + + 39449 / ZW4106 Plug-in Smart Switch + Plug-in Switch (Dual Plug Simultaneous Control) + http://www.openzwave.com/device-database/0039:3033:5052 + https://www.security.honeywellhome.com/product-repository/z5swpid + + images/honeywell/39449-ZW4106.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3740/39449-HQSG_v3.pdf + + + 1) Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network. + 2) Once the controller is ready to add your device, press and release the manual/program button on the smart switch. Repeat as necessary to add the switch to the network. + + + 1) Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network. + 2) Once the controller is ready to remove your device, press and release the manual/program button on the smart switch to remove it from the network. + + + 1) If plugged in, unplug the device from the receptacle. + 2) Press and hold the top button, plug the device in, and continue to hold for at least 3 seconds. + + https://products.z-wavealliance.org/products/3740?selectedFrequencyId=2 + U.S. / Canada / Mexico + 39449 / ZW4106 + + Initial metadata import from Z-Wave Alliance + Correct Path to Image File + + + + + + + Invert/Disable LED (Adjusts when the indicator LED is turned ON, OFF, or disables it entirely) + + + + + + + + + + + + + + + diff --git a/openzwave/honeywell/lynx-touch-l5100.xml b/openzwave/honeywell/lynx-touch-l5100.xml new file mode 100644 index 00000000..37622199 --- /dev/null +++ b/openzwave/honeywell/lynx-touch-l5100.xml @@ -0,0 +1,20 @@ + + + http://www.openzwave.com/device-database/0039:0003:0001 + images/honeywell/lynx-touch-l5100.png + https://products.z-wavealliance.org/products/678/ + L5100 + Honeywell Lynx Touch L5100 + U.S. / Canada / Mexico + Honeywell + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/678/xml + + + + diff --git a/openzwave/honeywell/th6320zw2003.xml b/openzwave/honeywell/th6320zw2003.xml new file mode 100644 index 00000000..96e98237 --- /dev/null +++ b/openzwave/honeywell/th6320zw2003.xml @@ -0,0 +1,429 @@ + + + http://www.openzwave.com/device-database/0039:0008:0011 + images/honeywell/th6320zw2003.png + https://products.z-wavealliance.org/products/2893/ + T6 Pro Z-Wave Programmable Thermostat + To include the thermostat in to Z-Wave network, go to thermostat MENU/ Z-Wave SETUP. +• Touch Select. You will be asked to set your primary controller to INCLUDE MODE. Please refer to the user manual of your Z-Wave controller. +• After inclusion procedure has been initiated on your Z-Wave controller, touch Select on the thermostat. +• If the inclusion procedure is successful, "INCLUDED", the node ID, and the Z-Wave connected status icon appear on the screen. +If the procedure fails, “FAILED TO INCLUDE” appears on the screen. +• Your controller will indicate whether the thermostat was successfully added to its network. Please refer to the user manual of your Z-Wave controller. + The Honeywell T6 Pro Z-Wave Programmable Thermostat is a Z-Wave Plus certified, universal thermostat capable to control up to three heat and two cool stages of heat pump, (incl. dual fuel heat pump systems) and up to two heat and two cool stages of conventional system (3H/2C HP, 2H/2C Conv.) +- 3 x AA battery or 24VAC powered +- Easy wiring, easy configuration +- Flexible local thermostat scheduling options +- Attractive look, large Easy-To-Read touchscreen +- Displays and reports ambient temperature and % Relative Indoor Humidity +- Displays and reports HVAC system status, battery power status, Z-Wave signal status +- Large amount of supported Z-Wave command classes +- Remotely configurable via Z-Wave configuration command class +- Advanced HVAC configuration parameters + U.S. / Canada / Mexico + TH6320ZW2003 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2893/33-00414-01-min.pdf + To exclude the thermostat from Z-Wave network, go to thermostat MENU/ Z-Wave SETUP. +• Touch Select. You will be asked to set your primary +controller to EXCLUDE MODE. Please refer to the user manual of your Z-Wave controller. +• After exclusion procedure has been initiated on your Z-Wave controller, touch Select on the thermostat. +• If the exclusion procedure is successful, "EXCLUDED", and the Z-Wave excluded status icon appear on the screen. +If the procedure fails, “FAILED TO EXCLUDE” appears on the screen. +• Your controller will indicate whether the thermostat was successfully excluded from its network. Please refer to the user manual of your Z-Wave controller. + To reset the thermostat to factory default setting, go to Installer setup – advanced menu. To access the advanced menu, press and hold the thermostat Menu button for 5 seconds. +Touch < or > to go to RESET menu. Press Select. Touch < or > to go to FACTORY. Press Select. Touch Yes to reset the thermostat to factory default settings.. +Please use the reset procedure only when the primary controller is missing or inoperable. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2583/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2893/xml + Thermostat requires 2 bytes for precision, not 1. Sending 1 results in decimal degrees (common in Celcius) setting the temperature to the minimum value. + + + + + + 0 + 2 + + + + + + Schedule Type + + + + + + + + + + Temperature Scale + + + + + + + Outdoor Temperature Sensor + + + + + + + Equipment Type + + + + + + + + + + + + + + + Reversing Valve + + + + + + + Stages + + + + + Stages + + + + + + + + + + Auxiliary Heat Control + + + + + + + Emergency Heat Type + + + + + + + Fossil Kit Control + + + + + + + ADVANCED PARAMETER SHOULD ONLY BE CHANGED FROM ITS DEFAULT VALUE BY A QUALIFIED HVAC PROFESSIONAL + + + + + + + Auto Differential in degrees Fahrenheit + + + + + High Cool Stage Finish + + + + + + + High Heat Stage Finish + + + + + + + 0 = Comfort (1 is not accepted) Integer from 2 to 15 degrees of Fahrenheit from setpoint + + + + + + + + + + + + + + + + + + + + Up Stage Timer Auxiliary Heat + + + + + + + + + + + + + + + + + + + + + 0 = Off integer from 5 to 65 degrees Fahrenheit in only 5 degrees increments. Other values not accepted. + + + + + + + + + + + + + + + + + 0 = Off integer from 5 to 65 degrees Fahrenheit in only 5 degrees increments. Other values not accepted. + + + + + + + + + + + + + + + + + Cycle rates per hour + + + + + Cycle rates per hour + + + + + Cycle rates per hour + + + + + Cycle rates per hour + + + + + Cycle rates per hour + + + + + Cycle rates per hour + + + + + 0 = Off Integer from 1-5 minutes + + + + + + + + + + + Adaptive Intelligent Recovery + + + + + + + Degrees Fahrenheit + + + + + Degrees Fahrenheit + + + + + Number of air filters + + + + + Air Filter 1 Reminder + + + + + + + + + + + + + + + + + + + + + + + + + Air Filter 2 Reminder + + + + + + + + + + + + + + + + + + + + + + + + + Humidification Pad Reminder + + + + + + + + 0 = Off, 1-12 Calendar Months + + + + + integer from 0 to 12 months. 0 = Off 3 = 3 Months 6 = 6 Months 9 = 9 Months 12 = 12 Months Other values not accepted. + + + + + + + + + + UV Devices + + + + + integer from 0 to 24 months. 0 = Off 6 = 6 Months 12 = 12 Months 24 = 24 Months Other values not accepted. + + + + + + + + + integer from 0 to 24 months. 0 = Off 6 = 6 Months 12 = 12 Months 24 = 24 Months Other values not accepted. + + + + + + + + + Brightness level + + + + + Clock Format + + + + + + + Daylight Saving + + + + + + + -3 = -3 deg Fahrenheit -2 = -2 deg Fahrenheit -1 = -1 deg Fahrenheit 0 = Off 1 = +1 deg Fahrenheit 2 = +2 deg Fahrenheit 3 = +3 deg Fahrenheit + + + + + + + + + + + + + + + + diff --git a/openzwave/honeywell/th8320zw1000.xml b/openzwave/honeywell/th8320zw1000.xml new file mode 100644 index 00000000..dbd19296 --- /dev/null +++ b/openzwave/honeywell/th8320zw1000.xml @@ -0,0 +1,24 @@ + + + http://www.openzwave.com/device-database/0039:0001:0011 + images/honeywell/th8320zw1000.png + https://products.z-wavealliance.org/products/44/ + http://yourhome.honeywell.com/home/Products/Thermostats/7-Day-Programmable/VisionPRO+8000.htm + Integrate comfort control into your automated home with Honeywell's most popular programmable thermostat, designed for Z-Wave systems! VisionPRO Z-Wave offers you top-of-the-line features like touchscreen interaction, a real-time clock, and a large, easy-to-read backlit display. + Vision PRO Z-Wave Thermostat + TH8320ZW1000 + U.S. / Canada / Mexico + http://honeywell.com/Products-Services/Pages/consumer-home.aspx + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/44/xml + Thermostat requires 2 bytes for precision, not 1. Sending 1 results in all decimal sets returning back to minimum value. + + + + + + 2 + 0 + + + diff --git a/openzwave/horstmann/asrzw.xml b/openzwave/horstmann/asrzw.xml new file mode 100644 index 00000000..a8360be1 --- /dev/null +++ b/openzwave/horstmann/asrzw.xml @@ -0,0 +1,21 @@ + + + http://www.openzwave.com/device-database/0059:0001:0003 + images/horstmann/asrzw.png + https://products.z-wavealliance.org/products/126/ + CEPT (Europe) + http://www.securetogether.eu/ + SSR301 + Secure SSR301 1ch Zwave Relay box (Rx) + ASR-RF is a mains powered receiver for connecting where a mains supply is readily available.AS2-RF thermostat transmits via Z Wave mesh radio technology and is capable of operation in most domestic houses with an operating range of approximately 30 metres. Ideal for controlling combi boilers, it can be mounted in any suitable location without the need to disturb existing wiring or décor. Operates from 3 standard AA batteries, with 2 years+ life and separate clock battery. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/125/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/126/xml + + + + + + + + diff --git a/openzwave/horstmann/hrt4zw.xml b/openzwave/horstmann/hrt4zw.xml new file mode 100644 index 00000000..baac8113 --- /dev/null +++ b/openzwave/horstmann/hrt4zw.xml @@ -0,0 +1,72 @@ + + + http://www.openzwave.com/device-database/0059:0003:0001 + images/horstmann/hrt4zw.png + https://products.z-wavealliance.org/products/115/ + CEPT (Europe) + ThermostatThe innovative Horstmann CentaurPlus ZW combined wireless room stat and time control offers installers and householders the opportunity to easily and cost effectively update existing combi boiler controls. + +The CentaurPlus has an integral transmitter and receiver, enabling wireless communication with the latest generation Horstmann HRT4-ZW TPI room thermostat. + +Suitable for combi boilers +Volt free contacts +Automatic BST /GMT time change +Back lit display +Boost and Advance +Helps to meet Part L1 of 2010 Building Regs for existing installations +Built in Z Wave receiver +Industry Standard 6 terminal wall plate +ZW wireless technology +TPI energy saving software +Clear backlit display +Temperature range 5-30°C +Battery operated for wire free installation + Secure SRT321 Zwave Stat (Tx) + http://www.securetogether.eu/ + SRT321 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/115/xml + + + + + + + + + + + + + 0 + + + + + + + + + + + + + + + + + Delta T in steps of 0.1 degree. + + + + + + + + + + + + + + diff --git a/openzwave/horstmann/scsc17.xml b/openzwave/horstmann/scsc17.xml new file mode 100644 index 00000000..be52ff87 --- /dev/null +++ b/openzwave/horstmann/scsc17.xml @@ -0,0 +1,59 @@ + + + http://www.openzwave.com/device-database/0059:0001:0004 + images/horstmann/scsc17.png + https://products.z-wavealliance.org/products/1740/ + http://www.horstmann.co.uk/central-heating.php + C17-ZW + CEPT (Europe) + C-Stat + C-Stat + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/864/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1740/xml + + + + + + + + + + false + + + + + + 0 + 0 + + + + + + Controls the temperature sensor scale + + + + + Defines the minimum temperature. Steps are 1C + + + Defines the maximum temperature. Steps are 1C + + + Change between temperatures to trigger a temperature report (step 0.1) + 1 to 50, 1 or 0.1 (Default 5 = 0,5C) -> (1C = 10) + + + + + + + + + + + diff --git a/openzwave/horstmann/ses301.xml b/openzwave/horstmann/ses301.xml new file mode 100644 index 00000000..096530b2 --- /dev/null +++ b/openzwave/horstmann/ses301.xml @@ -0,0 +1,16 @@ + + + http://www.openzwave.com/device-database/0059:0001:000D + images/horstmann/ses301.png + https://products.z-wavealliance.org/products/676/ + http://www.securetogether.eu/ + CEPT (Europe) + SES301 + Secure SES301 Temperature Sensor + Z-wave Temperature sensor is a battery operated device which is able to measure temperature and deliver the information to associates device in a Z-Wave networks. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/676/xml + + + + diff --git a/openzwave/horstmann/ses302.xml b/openzwave/horstmann/ses302.xml new file mode 100644 index 00000000..9d6ede4c --- /dev/null +++ b/openzwave/horstmann/ses302.xml @@ -0,0 +1,63 @@ + + + http://www.openzwave.com/device-database/0059:0002:000D + images/horstmann/ses302.png + https://products.z-wavealliance.org/products/1240/ + The Environmental Sensor (SES 302) measures temperature. The sensor is battery-operated devices which transmit information to an associated device in a network. It can support either 1 thermistor (SES 001) or up to 4 external digital temperature sensors (SES 002/003). SES 302 operates on 2x AA batteries, providing a nominal life of 2 years (with on-board sensors operating with the default configuration). + Step 1.On the Z-Wave controller, select Include for adding a device to the network. +Step 2: On the SES 302, press the button, hold and release after 1 second to send a request (Network Information Frame) to join the network. On successful inclusion the LED will flash 2 times. The total process can take up to 20 seconds. If the LED flashes 4-times this means that the inclusion process has failed, so try moving the SES 302 to another position and repeat the Inclusion steps. If the inclusion process fails again, the device may be already included in another network. So first exclude and then include the device. The controller will show when the inclusion operation is successful. + CEPT (Europe) + Device can be wakeup by button press of more then one second, devcie will stay in wakeup state for about 10 seconds. +device will also wakeup on the every wakeup interval configured by controller. The minimum wakeup interval can be configured is 2 minutes and maximum wakeup interval can be configured is 24 hours in setps of one minte. +Default wakeup interval is 24 hours. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1240/SES 302 and 303 TH Sensors User Installation Manual, (Secure Controls UK Ltd) BGX501-923-R02.pdf + SES 302 + Please use this procedure only when the primary controller is missing or otherwise inoperable. +To reset the device to factory resst, press the button 3 times within 3 seconds it will put the device in factory default, that include setting all the configuration, Association to factory default and removing the device from Z-Wave network. + Environmental Sensor + Step 1.On the Z-Wave controller, select exclusion for removing a device from the network. +Step 2: On the SES 302, press the button, hold and release after 1 second to send a request (Network Information Frame) to remove from the network. On successful exclusion the LED will flash 2 times. The total process can take up to 2 seconds. If the LED flashes 4-times this means that the exclusion process has failed, so try moving the SES 302 to another position and repeat the exclusion steps. The controller will show when the exclusion operation is successful. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1240/xml + + + + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Temperature reporting interval in minutes (Default 5 minutes) + + + Temperature reporting interval in minutes (Default 5 minutes) + + + Temperature reporting interval in minutes (Default 5 minutes) + + + Temperature reporting interval in minutes (Default 5 minutes) + + + Temperature reporting interval in minutes (Default 5 minutes) + + + + + + + + + diff --git a/openzwave/horstmann/ses303.xml b/openzwave/horstmann/ses303.xml new file mode 100644 index 00000000..3b27a529 --- /dev/null +++ b/openzwave/horstmann/ses303.xml @@ -0,0 +1,69 @@ + + + http://www.openzwave.com/device-database/0059:0003:000D + images/horstmann/ses303.png + https://products.z-wavealliance.org/products/1175/ + Step 1.On the Z-Wave controller, select Include for adding a device to the network. +Step 2: On the SES 303, press the button, hold and release after 1 second to send a request (Network Information Frame) to join the network. On successful inclusion the LED will flash 2 times. The total process can take up to 20 seconds. If the LED flashes 4-times this means that the inclusion process has failed, so try moving the SES 303 to another position and repeat the Inclusion steps. If the inclusion process fails again, the device may be already included in another network. So first exclude and then include the device. The controller will show when the inclusion operation is successful. + Please use this procedure only when the primary controller is missing or otherwise inoperable. +To reset the device to factory resst, press the button 3 times within 3 seconds it will put the device in factory default, that include setting all the configuration, Association to factory default and removing the device from Z-Wave network. + CEPT (Europe) + Device can be wakeup by button press of more then one second, devcie will stay in wakeup state for about 10 seconds. +device will also wakeup on the every wakeup interval configured by controller. The minimum wakeup interval can be configured is 2 minutes and maximum wakeup interval can be configured is 24 hours in setps of one minte. +Default wakeup interval is 24 hours. + SES 303 + Environmental Sensor + The Environmental Sensor (SES 303) measures temperature and humidity. The sensors are battery-operated devices which transmit information to an associated device in a network. It can support either 1 thermistor (SES 001) or up to 4 external digital temperature sensors (SES 002/003). SES 303 operates on 2x AA batteries, providing a nominal life of 2 years (with on-board sensors operating with the default configuration). + Step 1.On the Z-Wave controller, select exclusion for removing a device from the network. +Step 2: On the SES 303, press the button, hold and release after 1 second to send a request (Network Information Frame) to remove from the network. On successful exclusion the LED will flash 2 times. The total process can take up to 2 seconds. If the LED flashes 4-times this means that the exclusion process has failed, so try moving the SES 303 to another position and repeat the exclusion steps. The controller will show when the exclusion operation is successful. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1175/SES 302 - 303 TH Sensors User cum Installation Manual (Secure Controls UK Ltd) BGX501-923-R02.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1175/xml + + + + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Temperature reporting interval in minutes (Default 5 minutes) + + + Temperature reporting interval in minutes (Default 5 minutes) + + + Temperature reporting interval in minutes (Default 5 minutes) + + + Temperature reporting interval in minutes (Default 5 minutes) + + + Temperature reporting interval in minutes (Default 5 minutes) + + + Change between humidity to trigger a humidity report (Default 5 = 5% relative humidity) + + + Humidity reporting interval in minutes (Default 5 minutes) + + + + + + + + + diff --git a/openzwave/horstmann/sir321.xml b/openzwave/horstmann/sir321.xml new file mode 100644 index 00000000..dd79e608 --- /dev/null +++ b/openzwave/horstmann/sir321.xml @@ -0,0 +1,49 @@ + + + http://www.openzwave.com/device-database/0059:0002:0010 + images/horstmann/sir321.png + https://products.z-wavealliance.org/products/1012/ + SIR 321 + Secure Intelligent Relay is having One relay, and support of duration base schedule, measuring of temperature and delta and interval temperature reporting etc + CEPT (Europe) + Secure Controls SIR 321 Intelligent Relay + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1012/xml + + + + + + Enables or not the Fails Safe Timer + + + + + Controls the temperature sensor scale + + + + + Time interval to trigger a temperature report (step 1s) (Default 0 = disabled) + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 0 = disabled) + + + Temperature that when reached will cut off the switch + + + + + + true + + + + + + + + + + diff --git a/openzwave/horstmann/srt321.xml b/openzwave/horstmann/srt321.xml new file mode 100644 index 00000000..7d93c7ac --- /dev/null +++ b/openzwave/horstmann/srt321.xml @@ -0,0 +1,77 @@ + + + http://www.openzwave.com/device-database/0059:0005:0001 + images/horstmann/srt321.png + https://products.z-wavealliance.org/products/1563/ + STEP 1: On the SRT321, Set DIL switch 1 on the back of the unit to 'ON' position, scroll through the function menu by rotating the dial, select "E" and press the dial to activate Exclusion process. Now the character "E" starts flashing. +STEP 2: On the 3rd party device, select Exclusion for removing device from SRT321's network. +After successful Exclusion SRT321 displayed "EP" other wise displayed "EF" (Exclusion fail). +Note: Once the character starts flashing the installer has 60 seconds to activate the 3rd party device. +After successful Exclusion set DIL switch 1 to 'OFF' position to operate SRT321 in normal operation. +If the Exclusion process has failed more than once, try moving the SRT321 to another position and repeat the Exclusion steps. + SRT-321 (Thermostat-HVAC) + CEPT (Europe) + STEP 1: On the SRT321, set DIL switch 1 on the back of the unit to 'ON' position, scroll through the function menu by rotating the dial, select "I" and press the dial to activate Inclusion process. Now the character "I" starts flashing. +STEP 2: On the 3rd party device, select Inclusion for adding a device into SRT321's network. +After successful inclusion SRT321 displayed "IP" other wise displayed "IF" (Inclusion fail). +Note: Once the character starts flashing the installer has 60 seconds to activate the 3rd party device. +After successful Inclusion set DIL switch 1 to 'OFF' position to operate SRT321 in normal operation. +If the inclusion process fails more than once, the 3rd party device may be already included in another network. So first exclude and then include the device. + Please use this procedure only when the primary controller is missing or otherwise inoperable. +To reset the thermostat Set DIL switch 1 on the back of the unit to 'ON' position, scroll through the function menu by rotating the dial, select "P" and press the dial twice on the target device to execute reset. +Note: After successful operation device displayed "PP". +It will put the device in factory default, that include setting all the configuration, Association to factory default and removing the device from Z-Wave network. + MAX10U-734 + SRT321 will wake-up regularly and announce the wakeup state by sending Wakeup Notification to the configured node ID if Wakeup Interval and valid node ID is set. +To forcefully wake up the device to send Wakeup notification do the following steps: Set DIL switch 1 on the back of the unit to 'ON' position, and than back to the 'OFF' position. +Note: It is possible to set the node ID to 255 to send wakeup notifications as broadcast. In this mode device takes more time to go to sleep and drains battery faster, but can notify all it's direct neighbors about a wakeup. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1563/SRT321 User MAnual.pdf + The thermostat includes TPI software that optimises boiler firing to minimise overshooting of temperature in a heated environment. It has been proved that TPI controllers provide considerable energy savings over standard heating controllers. By using interoperable radio solutions the user can remotely change the set point, read the temperature or receive battery reports. It makes this device an ideal partner for use with a home gateway for web enabled apps allowing you to remotely control your heating while on the move. You no longer have to worry about returning to a cold house as long as you have a phone or tablet PC handy. +By combining ease of use, ease of installation and intelligent control this thermostat is suitable for use in most heating systems. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1563/xml + + + + + + + + + + + + + 0 + + + + + + Enables Temperature Sensor + + + + + + + + + + + Delta Temperature in 0.1 degree steps. + + + + + + + + + + + + + + + diff --git a/openzwave/horstmann/srt323.xml b/openzwave/horstmann/srt323.xml new file mode 100644 index 00000000..043f4541 --- /dev/null +++ b/openzwave/horstmann/srt323.xml @@ -0,0 +1,46 @@ + + + http://www.openzwave.com/device-database/0059:0004:0001 + images/horstmann/srt323.png + https://products.z-wavealliance.org/products/1241/ + CEPT (Europe) + 323 + Room thermostat + Secure Controls SRT 323 Thermostat + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1241/xml + + + + + + 0 + + + + + + Enables or not the temperature sensor reading + + + + + Controls the temperature sensor scale + + + + + Change between temperatures to trigger a temperature report (step 0.1) (Default 10 = 1C) + + + + + + + + + + + + + diff --git a/openzwave/horstmann/ssr302.xml b/openzwave/horstmann/ssr302.xml new file mode 100644 index 00000000..417d4bbd --- /dev/null +++ b/openzwave/horstmann/ssr302.xml @@ -0,0 +1,71 @@ + + + http://www.openzwave.com/device-database/0059:0002:0003 + images/horstmann/ssr302.png + https://products.z-wavealliance.org/products/116/ + AS2-RF thermostat transmits via Z Wave mesh radio technology and is capable of operation in most domestic houses with an operating range of approximately 30 metres. Ideal for controlling combi boilers, it can be mounted in any suitable location without the need to disturb existing wiring or décor. Operates from 3 standard AA batteries, with 2 years+ life and separate clock battery. + SSR302 + CEPT (Europe) + Secure SSR302 2ch Zwave Relay Box (Rx) + http://www.securetogether.eu/ + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/116/xml + + + + + + + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/horstmann/ssr303.xml b/openzwave/horstmann/ssr303.xml new file mode 100644 index 00000000..19a6b350 --- /dev/null +++ b/openzwave/horstmann/ssr303.xml @@ -0,0 +1,73 @@ + + + http://www.openzwave.com/device-database/0059:0005:0003 + images/horstmann/ssr303.png + https://products.z-wavealliance.org/products/1618/ + CEPT (Europe) + The SSR 303 is a single channel relay/switch, it forms part of central heating control system, it can be operated by any third party controllers/Thermostat using ‘Binary Switch CC’ commands. + +SSR 303 will act as a repeater once added into the Z- Wave network, providing an alternative communication route for units which otherwise would not be within communication distance of each other. + +SSR 303 has a fail-safe mode where by the relay is turned OFF if another 'Thermostat Mode SET' command has not been received within 60 minutes. + STEP 1: Ensure the Network LED is flashing on the SSR 303, if not follow ‘Exclusion’ steps first. +STEP 2: Put the 3rd party controller into inclusion mode. +STEP 3: Press and hold the network button on the SSR 303 until the ‘ON’ LED’s start flashing. +The SSR 303 has been added onto the network when the ‘OFF’ LED goes solid red. + +NOTE: If the ON LED does not flash then the add process has been unsuccessful. + MAX10Z-384 + STEP 1: Put the 3rd party controller into exclusion mode. +STEP 2: Press and hold the network button on the SSR 303. +The SSR 303 has been removed from the network when the Network LED starts flashing. + +NOTE: If the Network LED does not flash the remove process has been unsuccessful. + SSR 303 (Single Channel On/Off Power switch) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1618/SSR 303 User Manual.pdf + "Please use this procedure only when the primary controller is missing or otherwise inoperable." + +Follow ‘Exclusion’ steps. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1618/xml + + + + + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/icare/zw-66.xml b/openzwave/icare/zw-66.xml new file mode 100644 index 00000000..7da3f824 --- /dev/null +++ b/openzwave/icare/zw-66.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/0012:0001:0001 + images/icare/zw-66.png + https://products.z-wavealliance.org/products/938/ + U.S. / Canada / Mexico + ZW-66 + Sanjose USB Dongle + USB Adapter + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/938/xml + + + diff --git a/openzwave/idlock/idlock101.xml b/openzwave/idlock/idlock101.xml new file mode 100644 index 00000000..f6ec4d11 --- /dev/null +++ b/openzwave/idlock/idlock101.xml @@ -0,0 +1,75 @@ + + + http://www.openzwave.com/device-database/0230:0001:0003 + images/idlock/idlock101.png + https://products.z-wavealliance.org/products/1512/ + Exclusion – (Puts your device in exclusion mode) +• Push and hold button until all LEDs on keypad activates. (with ID Lock in an unlocked state) +• Release button and press “8” on keypad. +Exclusion mode starts immediately. LED indicator below logo signals this by flashing blue. + 01A + CEPT (Europe) + Device reset – (This will reset RF interface module to factory default settings) +Warning: Please do only proceed with the following reset procedure, if primary network controller is missing or otherwise +inoperable. + +RESET Z-WAVE MODULE: +Activate doorlock service menu, by holding inside push button for 5sec while door is in OPEN state. + +Outside touchpanel activates > Push "0" + +FACTORY RESET DOORLOCK FIRMWARE: +1. Push innside pushbutton continously for five Seconds after inserting batteries. +2. Receive reset sound +3. Receive confirmation sound + + + Activate by touching numpad with two fingers or handpalm + Inclusion – (Puts your device in inclusion mode) +• Push and hold button until all LEDs on keypad activates. (with ID Lock in an unlocked state) +• Release button and press “8” on keypad. +Inclusion mode starts immediately. LED indicator below logo signals this by flashing blue. + UART console communication module turns your ID Lock digital doorlock into a Z-Wave Plus enabled digital doorlock. + +It enables your ID Lock to operate in a Z-Wave network with numerous access control funtions and notifications. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1512/IDL Operational Manual EN v1.2.pdf + ID Lock Z-Wave module + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1512/xml + + + + + + + + + Door Lock Mode + Autolock Mode, Manuallock mode, Activate Away Mode, Deactivate Away Mode. + Default Value : 1 ( Disable Away / Auto Lock Mode ) + + + + + + + + + RFID Registration Configuration + IDLocks can use up to 50 RFID cards. In order to use a RFID, RFID has to be registered by z-wave configuration command class. + Configuration Set in case of starting to register from backend side ( Ex. App) + + + + + + + + + + + + + + + diff --git a/openzwave/idlock/idlock150.xml b/openzwave/idlock/idlock150.xml new file mode 100644 index 00000000..77efe3b6 --- /dev/null +++ b/openzwave/idlock/idlock150.xml @@ -0,0 +1,171 @@ + + + ID Lock 150 Z-Wave module + A module enabling your ID Lock digital door lock to a Z-Wave Plus enabled digital door Lock. + +The module is compatible with ID Lock 101 and ID Lock 150. + +It enables your ID Lock to operate in a Z-Wave network with numerous access control funtions and notifications. + http://www.openzwave.com/device-database/0373:0001:0003 + https://idlock.no/z-wave/ + https://idlock.no/kundesenter/ + images/idlock/idlock150.png + https://idlock.no/wp-content/uploads/2019/08/IDLock150_ZWave_UserManual_v3.02.pdf + Activate by touching the touch panel with finger(s), the palm of the hand on the outside unit or by pushing the key button on the inside unit. + Inclusion – (Puts your device in inclusion mode) + +• Push and hold key button until all LEDs on touch panel activates (with ID Lock in an unlocked state). +• Release button. +• Enter Master PIN followed by * on touch panel. +• Press digit "2" for settings followed by * on touch panel. +• Press digit “5” on touch panel. + +Inclusion mode starts immediately. LED indicator below logo signals this by flashing blue. + Exclusion – (Puts your device in exclusion mode) + +• Push and hold key button until all LEDs on touch panel activates (with ID Lock in an unlocked state). +• Release button. +• Enter Master PIN followed by * on touch panel. +• Press digit "2" for settings followed by * on touch panel. +• Press digit “5” on touch panel. + +Exclusion mode starts immediately. LED indicator below logo signals this by flashing blue. + Device reset – (This will reset RF interface module to factory default settings) +Warning: Please do only proceed with the following reset procedure, if primary network controller is missing or otherwise inoperable. + +RESET Z-WAVE MODULE: + +• Push and hold key button until all LEDs on touch panel activates (with ID Lock in an unlocked state). +• Release button. +• Enter Master PIN followed by * on keypad. +• Press digit "2" for settings followed by * on keypad. +• Press digit “0” on keypad. + +If the Z-wave module is not included in a Z-wave network the door lock will also return to factory settings when following the above procedure. + +FACTORY RESET DOOR LOCK FIRMWARE: + +• Push and hold inside lock/unlock button while inserting the fourth battery. +• Receive reset sound. +• Release button. +• Receive confirmation sound. + https://products.z-wavealliance.org/products/2780/ + CEPT (Europe) + ID-150 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2780/xml + Update as per the 1.4.9/1.6 firmware specification + Update as per the 1.5.6/1.6 firmware specification + + + + + + + + + Door Lock Mode + Autolock Mode, Manual lock mode, Activate Away Mode, Deactivate Away Mode + Default Value : 1 ( Auto lock, Away off ) + + + + + + + + + RFID Mode + RFID activated + RFID deactivated + Default Value: 5 (RFID activated) + + + + + + + Door Hinge Position + Default Value : 0 (Right hinged operation) + + + + + + + Door Audio Volume Level + This parameter is a set only parameter. If the value is changed locally on the door lock, this value will not change. + Default Value : 5 + + + + + + + + + + + + Door ReLock Mode + Default Value: 1 (Enabled) + + + + + + + Service PIN Mode + A configuration get command on this parameter returns the latest set parameter value (set by Z-wave). + This is a set only value, if changed locally on keypad these values are not changed on Z-wave module. Value 5 and 6 will generate a random PIN in location 108. + Disabled: Disables both PIN and Service PIN menu on door lock + + Default Value: 0 (Deactivated) + + + + + + + + + + + + + + + + Door Lock Model Type + This configuration is only accepted by configuration get command + It is a read only parameter. Default value depends on the door lock model type. + + + + + Updater Mode + + Enables use of the Updater app. + Default Value: 0 (Off, no sound) + + + + + + + + + Master PIN Unlock Mode + + + + + + + + + + + + + diff --git a/openzwave/images/2gig/ct100.png b/openzwave/images/2gig/ct100.png new file mode 100644 index 00000000..ec9fd0b2 Binary files /dev/null and b/openzwave/images/2gig/ct100.png differ diff --git a/openzwave/images/2gig/ct32.png b/openzwave/images/2gig/ct32.png new file mode 100644 index 00000000..27452c62 Binary files /dev/null and b/openzwave/images/2gig/ct32.png differ diff --git a/openzwave/images/BeNext/AlarmSound.png b/openzwave/images/BeNext/AlarmSound.png new file mode 100644 index 00000000..e32815ad Binary files /dev/null and b/openzwave/images/BeNext/AlarmSound.png differ diff --git a/openzwave/images/BeNext/DoorSensor.png b/openzwave/images/BeNext/DoorSensor.png new file mode 100644 index 00000000..b374f56f Binary files /dev/null and b/openzwave/images/BeNext/DoorSensor.png differ diff --git a/openzwave/images/BeNext/Molite.png b/openzwave/images/BeNext/Molite.png new file mode 100644 index 00000000..42e44be9 Binary files /dev/null and b/openzwave/images/BeNext/Molite.png differ diff --git a/openzwave/images/BeNext/P1dongle.png b/openzwave/images/BeNext/P1dongle.png new file mode 100644 index 00000000..6d972b07 Binary files /dev/null and b/openzwave/images/BeNext/P1dongle.png differ diff --git a/openzwave/images/BeNext/TagReader.png b/openzwave/images/BeNext/TagReader.png new file mode 100644 index 00000000..5553a792 Binary files /dev/null and b/openzwave/images/BeNext/TagReader.png differ diff --git a/openzwave/images/BeNext/TagReader500.png b/openzwave/images/BeNext/TagReader500.png new file mode 100644 index 00000000..5d3fc342 Binary files /dev/null and b/openzwave/images/BeNext/TagReader500.png differ diff --git a/openzwave/images/BeNext/mydisplay.png b/openzwave/images/BeNext/mydisplay.png new file mode 100644 index 00000000..037d83d3 Binary files /dev/null and b/openzwave/images/BeNext/mydisplay.png differ diff --git a/openzwave/images/BeNext/mygate.png b/openzwave/images/BeNext/mygate.png new file mode 100644 index 00000000..c5e0aa0f Binary files /dev/null and b/openzwave/images/BeNext/mygate.png differ diff --git a/openzwave/images/DefaultProductImage.png b/openzwave/images/DefaultProductImage.png new file mode 100644 index 00000000..a464a829 Binary files /dev/null and b/openzwave/images/DefaultProductImage.png differ diff --git a/openzwave/images/abus/SHRM10000.jpg b/openzwave/images/abus/SHRM10000.jpg new file mode 100644 index 00000000..20fc7e2c Binary files /dev/null and b/openzwave/images/abus/SHRM10000.jpg differ diff --git a/openzwave/images/act/lfm20.png b/openzwave/images/act/lfm20.png new file mode 100644 index 00000000..0200b76d Binary files /dev/null and b/openzwave/images/act/lfm20.png differ diff --git a/openzwave/images/act/zdm230.png b/openzwave/images/act/zdm230.png new file mode 100644 index 00000000..5228903d Binary files /dev/null and b/openzwave/images/act/zdm230.png differ diff --git a/openzwave/images/act/zdp100.png b/openzwave/images/act/zdp100.png new file mode 100644 index 00000000..0f8cce01 Binary files /dev/null and b/openzwave/images/act/zdp100.png differ diff --git a/openzwave/images/act/zir010.png b/openzwave/images/act/zir010.png new file mode 100644 index 00000000..b3d21c0b Binary files /dev/null and b/openzwave/images/act/zir010.png differ diff --git a/openzwave/images/act/zrm230.png b/openzwave/images/act/zrm230.png new file mode 100644 index 00000000..f6400316 Binary files /dev/null and b/openzwave/images/act/zrm230.png differ diff --git a/openzwave/images/act/zrp100.png b/openzwave/images/act/zrp100.png new file mode 100644 index 00000000..b6eb1680 Binary files /dev/null and b/openzwave/images/act/zrp100.png differ diff --git a/openzwave/images/act/zrw103.png b/openzwave/images/act/zrw103.png new file mode 100644 index 00000000..36103a07 Binary files /dev/null and b/openzwave/images/act/zrw103.png differ diff --git a/openzwave/images/act/zrw230.png b/openzwave/images/act/zrw230.png new file mode 100644 index 00000000..0b46ba5f Binary files /dev/null and b/openzwave/images/act/zrw230.png differ diff --git a/openzwave/images/aeotec/dsa03202.png b/openzwave/images/aeotec/dsa03202.png new file mode 100644 index 00000000..1966d754 Binary files /dev/null and b/openzwave/images/aeotec/dsa03202.png differ diff --git a/openzwave/images/aeotec/dsa38.png b/openzwave/images/aeotec/dsa38.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/aeotec/dsa38.png differ diff --git a/openzwave/images/aeotec/dsb04100.png b/openzwave/images/aeotec/dsb04100.png new file mode 100644 index 00000000..9ba852a8 Binary files /dev/null and b/openzwave/images/aeotec/dsb04100.png differ diff --git a/openzwave/images/aeotec/dsb05.png b/openzwave/images/aeotec/dsb05.png new file mode 100644 index 00000000..ab1db1c5 Binary files /dev/null and b/openzwave/images/aeotec/dsb05.png differ diff --git a/openzwave/images/aeotec/dsb09104.png b/openzwave/images/aeotec/dsb09104.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/aeotec/dsb09104.png differ diff --git a/openzwave/images/aeotec/dsb28-zweu.png b/openzwave/images/aeotec/dsb28-zweu.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/aeotec/dsb28-zweu.png differ diff --git a/openzwave/images/aeotec/dsb28.png b/openzwave/images/aeotec/dsb28.png new file mode 100644 index 00000000..03046e9b Binary files /dev/null and b/openzwave/images/aeotec/dsb28.png differ diff --git a/openzwave/images/aeotec/dsb29.png b/openzwave/images/aeotec/dsb29.png new file mode 100644 index 00000000..525b003d Binary files /dev/null and b/openzwave/images/aeotec/dsb29.png differ diff --git a/openzwave/images/aeotec/dsc06106.png b/openzwave/images/aeotec/dsc06106.png new file mode 100644 index 00000000..7846f57c Binary files /dev/null and b/openzwave/images/aeotec/dsc06106.png differ diff --git a/openzwave/images/aeotec/dsc10.png b/openzwave/images/aeotec/dsc10.png new file mode 100644 index 00000000..3541de43 Binary files /dev/null and b/openzwave/images/aeotec/dsc10.png differ diff --git a/openzwave/images/aeotec/dsc11.png b/openzwave/images/aeotec/dsc11.png new file mode 100644 index 00000000..087bac28 Binary files /dev/null and b/openzwave/images/aeotec/dsc11.png differ diff --git a/openzwave/images/aeotec/dsc14104.png b/openzwave/images/aeotec/dsc14104.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/aeotec/dsc14104.png differ diff --git a/openzwave/images/aeotec/dsc18103.png b/openzwave/images/aeotec/dsc18103.png new file mode 100644 index 00000000..e3d2f922 Binary files /dev/null and b/openzwave/images/aeotec/dsc18103.png differ diff --git a/openzwave/images/aeotec/dsc19103.png b/openzwave/images/aeotec/dsc19103.png new file mode 100644 index 00000000..e3d2f922 Binary files /dev/null and b/openzwave/images/aeotec/dsc19103.png differ diff --git a/openzwave/images/aeotec/dsc24.png b/openzwave/images/aeotec/dsc24.png new file mode 100644 index 00000000..25dd6c16 Binary files /dev/null and b/openzwave/images/aeotec/dsc24.png differ diff --git a/openzwave/images/aeotec/dsc26103.png b/openzwave/images/aeotec/dsc26103.png new file mode 100644 index 00000000..e3d2f922 Binary files /dev/null and b/openzwave/images/aeotec/dsc26103.png differ diff --git a/openzwave/images/aeotec/dsc27103.png b/openzwave/images/aeotec/dsc27103.png new file mode 100644 index 00000000..e3d2f922 Binary files /dev/null and b/openzwave/images/aeotec/dsc27103.png differ diff --git a/openzwave/images/aeotec/dsc35103.png b/openzwave/images/aeotec/dsc35103.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/aeotec/dsc35103.png differ diff --git a/openzwave/images/aeotec/dsd37.png b/openzwave/images/aeotec/dsd37.png new file mode 100644 index 00000000..9ac083e5 Binary files /dev/null and b/openzwave/images/aeotec/dsd37.png differ diff --git a/openzwave/images/aeotec/zw056.png b/openzwave/images/aeotec/zw056.png new file mode 100644 index 00000000..80e6a56a Binary files /dev/null and b/openzwave/images/aeotec/zw056.png differ diff --git a/openzwave/images/aeotec/zw062.png b/openzwave/images/aeotec/zw062.png new file mode 100644 index 00000000..70ccf590 Binary files /dev/null and b/openzwave/images/aeotec/zw062.png differ diff --git a/openzwave/images/aeotec/zw074.png b/openzwave/images/aeotec/zw074.png new file mode 100644 index 00000000..2084f0f2 Binary files /dev/null and b/openzwave/images/aeotec/zw074.png differ diff --git a/openzwave/images/aeotec/zw075.png b/openzwave/images/aeotec/zw075.png new file mode 100644 index 00000000..a9dd5e90 Binary files /dev/null and b/openzwave/images/aeotec/zw075.png differ diff --git a/openzwave/images/aeotec/zw078.png b/openzwave/images/aeotec/zw078.png new file mode 100644 index 00000000..84f7cf8e Binary files /dev/null and b/openzwave/images/aeotec/zw078.png differ diff --git a/openzwave/images/aeotec/zw080.png b/openzwave/images/aeotec/zw080.png new file mode 100644 index 00000000..85818d15 Binary files /dev/null and b/openzwave/images/aeotec/zw080.png differ diff --git a/openzwave/images/aeotec/zw088.png b/openzwave/images/aeotec/zw088.png new file mode 100644 index 00000000..4bbe3ecc Binary files /dev/null and b/openzwave/images/aeotec/zw088.png differ diff --git a/openzwave/images/aeotec/zw089.png b/openzwave/images/aeotec/zw089.png new file mode 100644 index 00000000..3d0b99a8 Binary files /dev/null and b/openzwave/images/aeotec/zw089.png differ diff --git a/openzwave/images/aeotec/zw090.png b/openzwave/images/aeotec/zw090.png new file mode 100644 index 00000000..1209ff8c Binary files /dev/null and b/openzwave/images/aeotec/zw090.png differ diff --git a/openzwave/images/aeotec/zw095.png b/openzwave/images/aeotec/zw095.png new file mode 100644 index 00000000..2f99fb3c Binary files /dev/null and b/openzwave/images/aeotec/zw095.png differ diff --git a/openzwave/images/aeotec/zw096.png b/openzwave/images/aeotec/zw096.png new file mode 100644 index 00000000..6e6e7c2b Binary files /dev/null and b/openzwave/images/aeotec/zw096.png differ diff --git a/openzwave/images/aeotec/zw097.png b/openzwave/images/aeotec/zw097.png new file mode 100644 index 00000000..593592ae Binary files /dev/null and b/openzwave/images/aeotec/zw097.png differ diff --git a/openzwave/images/aeotec/zw098.png b/openzwave/images/aeotec/zw098.png new file mode 100644 index 00000000..fcfc7426 Binary files /dev/null and b/openzwave/images/aeotec/zw098.png differ diff --git a/openzwave/images/aeotec/zw099.png b/openzwave/images/aeotec/zw099.png new file mode 100644 index 00000000..2e3a1c89 Binary files /dev/null and b/openzwave/images/aeotec/zw099.png differ diff --git a/openzwave/images/aeotec/zw100.png b/openzwave/images/aeotec/zw100.png new file mode 100644 index 00000000..329d37ee Binary files /dev/null and b/openzwave/images/aeotec/zw100.png differ diff --git a/openzwave/images/aeotec/zw111.png b/openzwave/images/aeotec/zw111.png new file mode 100644 index 00000000..d285be89 Binary files /dev/null and b/openzwave/images/aeotec/zw111.png differ diff --git a/openzwave/images/aeotec/zw112.png b/openzwave/images/aeotec/zw112.png new file mode 100644 index 00000000..4efcec75 Binary files /dev/null and b/openzwave/images/aeotec/zw112.png differ diff --git a/openzwave/images/aeotec/zw116.png b/openzwave/images/aeotec/zw116.png new file mode 100644 index 00000000..d285be89 Binary files /dev/null and b/openzwave/images/aeotec/zw116.png differ diff --git a/openzwave/images/aeotec/zw117.png b/openzwave/images/aeotec/zw117.png new file mode 100644 index 00000000..8094d4f0 Binary files /dev/null and b/openzwave/images/aeotec/zw117.png differ diff --git a/openzwave/images/aeotec/zw120.png b/openzwave/images/aeotec/zw120.png new file mode 100644 index 00000000..61bdf9a9 Binary files /dev/null and b/openzwave/images/aeotec/zw120.png differ diff --git a/openzwave/images/aeotec/zw121.png b/openzwave/images/aeotec/zw121.png new file mode 100644 index 00000000..11eb27f8 Binary files /dev/null and b/openzwave/images/aeotec/zw121.png differ diff --git a/openzwave/images/aeotec/zw122.png b/openzwave/images/aeotec/zw122.png new file mode 100644 index 00000000..b1383c79 Binary files /dev/null and b/openzwave/images/aeotec/zw122.png differ diff --git a/openzwave/images/aeotec/zw129.png b/openzwave/images/aeotec/zw129.png new file mode 100644 index 00000000..7505874e Binary files /dev/null and b/openzwave/images/aeotec/zw129.png differ diff --git a/openzwave/images/aeotec/zw130.png b/openzwave/images/aeotec/zw130.png new file mode 100644 index 00000000..0108d745 Binary files /dev/null and b/openzwave/images/aeotec/zw130.png differ diff --git a/openzwave/images/aeotec/zw132.png b/openzwave/images/aeotec/zw132.png new file mode 100644 index 00000000..90d2a6b7 Binary files /dev/null and b/openzwave/images/aeotec/zw132.png differ diff --git a/openzwave/images/aeotec/zw139.png b/openzwave/images/aeotec/zw139.png new file mode 100644 index 00000000..d285be89 Binary files /dev/null and b/openzwave/images/aeotec/zw139.png differ diff --git a/openzwave/images/aeotec/zw140.png b/openzwave/images/aeotec/zw140.png new file mode 100644 index 00000000..90d2a6b7 Binary files /dev/null and b/openzwave/images/aeotec/zw140.png differ diff --git a/openzwave/images/aeotec/zw141.png b/openzwave/images/aeotec/zw141.png new file mode 100644 index 00000000..90d2a6b7 Binary files /dev/null and b/openzwave/images/aeotec/zw141.png differ diff --git a/openzwave/images/aeotec/zw162.png b/openzwave/images/aeotec/zw162.png new file mode 100644 index 00000000..27ff27cc Binary files /dev/null and b/openzwave/images/aeotec/zw162.png differ diff --git a/openzwave/images/aeotec/zw164.png b/openzwave/images/aeotec/zw164.png new file mode 100644 index 00000000..17be7a79 Binary files /dev/null and b/openzwave/images/aeotec/zw164.png differ diff --git a/openzwave/images/aeotec/zw187.png b/openzwave/images/aeotec/zw187.png new file mode 100644 index 00000000..3d0b99a8 Binary files /dev/null and b/openzwave/images/aeotec/zw187.png differ diff --git a/openzwave/images/aeotec/zw189.png b/openzwave/images/aeotec/zw189.png new file mode 100644 index 00000000..8094d4f0 Binary files /dev/null and b/openzwave/images/aeotec/zw189.png differ diff --git a/openzwave/images/aeotec/zw195.png b/openzwave/images/aeotec/zw195.png new file mode 100644 index 00000000..bed322b3 Binary files /dev/null and b/openzwave/images/aeotec/zw195.png differ diff --git a/openzwave/images/aeotec/zwa001.png b/openzwave/images/aeotec/zwa001.png new file mode 100644 index 00000000..a48b9fbb Binary files /dev/null and b/openzwave/images/aeotec/zwa001.png differ diff --git a/openzwave/images/aeotec/zwa002.png b/openzwave/images/aeotec/zwa002.png new file mode 100644 index 00000000..c5603e56 Binary files /dev/null and b/openzwave/images/aeotec/zwa002.png differ diff --git a/openzwave/images/aeotec/zwa003.png b/openzwave/images/aeotec/zwa003.png new file mode 100644 index 00000000..f7dcb051 Binary files /dev/null and b/openzwave/images/aeotec/zwa003.png differ diff --git a/openzwave/images/aeotec/zwa004.png b/openzwave/images/aeotec/zwa004.png new file mode 100644 index 00000000..67eb10dc Binary files /dev/null and b/openzwave/images/aeotec/zwa004.png differ diff --git a/openzwave/images/aeotec/zwa005.png b/openzwave/images/aeotec/zwa005.png new file mode 100644 index 00000000..e07210f1 Binary files /dev/null and b/openzwave/images/aeotec/zwa005.png differ diff --git a/openzwave/images/aeotec/zwa006.png b/openzwave/images/aeotec/zwa006.png new file mode 100644 index 00000000..99672a6e Binary files /dev/null and b/openzwave/images/aeotec/zwa006.png differ diff --git a/openzwave/images/aeotec/zwa009.png b/openzwave/images/aeotec/zwa009.png new file mode 100644 index 00000000..312d6e72 Binary files /dev/null and b/openzwave/images/aeotec/zwa009.png differ diff --git a/openzwave/images/aeotec/zwa012.png b/openzwave/images/aeotec/zwa012.png new file mode 100644 index 00000000..88cdbab8 Binary files /dev/null and b/openzwave/images/aeotec/zwa012.png differ diff --git a/openzwave/images/aeotec/zwa019.png b/openzwave/images/aeotec/zwa019.png new file mode 100644 index 00000000..9d16bcb0 Binary files /dev/null and b/openzwave/images/aeotec/zwa019.png differ diff --git a/openzwave/images/aeotec/zwa021.png b/openzwave/images/aeotec/zwa021.png new file mode 100644 index 00000000..28cfdab6 Binary files /dev/null and b/openzwave/images/aeotec/zwa021.png differ diff --git a/openzwave/images/airlinemechanical/zds-ud10.png b/openzwave/images/airlinemechanical/zds-ud10.png new file mode 100644 index 00000000..8919972c Binary files /dev/null and b/openzwave/images/airlinemechanical/zds-ud10.png differ diff --git a/openzwave/images/alfred/DB2.png b/openzwave/images/alfred/DB2.png new file mode 100644 index 00000000..8924c88b Binary files /dev/null and b/openzwave/images/alfred/DB2.png differ diff --git a/openzwave/images/assa_abloy/ConexisL1.png b/openzwave/images/assa_abloy/ConexisL1.png new file mode 100644 index 00000000..fecc07e3 Binary files /dev/null and b/openzwave/images/assa_abloy/ConexisL1.png differ diff --git a/openzwave/images/assa_abloy/KeyfreeConnected-plus.png b/openzwave/images/assa_abloy/KeyfreeConnected-plus.png new file mode 100644 index 00000000..20cf676e Binary files /dev/null and b/openzwave/images/assa_abloy/KeyfreeConnected-plus.png differ diff --git a/openzwave/images/assa_abloy/KeyfreeConnected.png b/openzwave/images/assa_abloy/KeyfreeConnected.png new file mode 100644 index 00000000..e1cd54b8 Binary files /dev/null and b/openzwave/images/assa_abloy/KeyfreeConnected.png differ diff --git a/openzwave/images/assa_abloy/PushButtonDeadbolt.png b/openzwave/images/assa_abloy/PushButtonDeadbolt.png new file mode 100644 index 00000000..7d250a86 Binary files /dev/null and b/openzwave/images/assa_abloy/PushButtonDeadbolt.png differ diff --git a/openzwave/images/assa_abloy/TouchDeadbolt.png b/openzwave/images/assa_abloy/TouchDeadbolt.png new file mode 100644 index 00000000..a4346c8c Binary files /dev/null and b/openzwave/images/assa_abloy/TouchDeadbolt.png differ diff --git a/openzwave/images/assa_abloy/TouchLever.png b/openzwave/images/assa_abloy/TouchLever.png new file mode 100644 index 00000000..ec0a999a Binary files /dev/null and b/openzwave/images/assa_abloy/TouchLever.png differ diff --git a/openzwave/images/assa_abloy/nexTouch.png b/openzwave/images/assa_abloy/nexTouch.png new file mode 100644 index 00000000..d35c1089 Binary files /dev/null and b/openzwave/images/assa_abloy/nexTouch.png differ diff --git a/openzwave/images/assa_abloy/yrd1x0.png b/openzwave/images/assa_abloy/yrd1x0.png new file mode 100644 index 00000000..bbcf13d3 Binary files /dev/null and b/openzwave/images/assa_abloy/yrd1x0.png differ diff --git a/openzwave/images/august/asl-03.png b/openzwave/images/august/asl-03.png new file mode 100644 index 00000000..b70caa42 Binary files /dev/null and b/openzwave/images/august/asl-03.png differ diff --git a/openzwave/images/buffalo/hw-100v15a-zw.png b/openzwave/images/buffalo/hw-100v15a-zw.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/buffalo/hw-100v15a-zw.png differ diff --git a/openzwave/images/building36/b36-t10.png b/openzwave/images/building36/b36-t10.png new file mode 100644 index 00000000..371cb591 Binary files /dev/null and b/openzwave/images/building36/b36-t10.png differ diff --git a/openzwave/images/comfort/ucm.png b/openzwave/images/comfort/ucm.png new file mode 100644 index 00000000..4c737184 Binary files /dev/null and b/openzwave/images/comfort/ucm.png differ diff --git a/openzwave/images/connecthome/CH_201.png b/openzwave/images/connecthome/CH_201.png new file mode 100644 index 00000000..004f5fe3 Binary files /dev/null and b/openzwave/images/connecthome/CH_201.png differ diff --git a/openzwave/images/cooper/RF9501.png b/openzwave/images/cooper/RF9501.png new file mode 100644 index 00000000..e4a1834a Binary files /dev/null and b/openzwave/images/cooper/RF9501.png differ diff --git a/openzwave/images/cooper/RF9505-T.png b/openzwave/images/cooper/RF9505-T.png new file mode 100644 index 00000000..b75e3a60 Binary files /dev/null and b/openzwave/images/cooper/RF9505-T.png differ diff --git a/openzwave/images/cooper/RF9517.png b/openzwave/images/cooper/RF9517.png new file mode 100644 index 00000000..e4a1834a Binary files /dev/null and b/openzwave/images/cooper/RF9517.png differ diff --git a/openzwave/images/cooper/RF9540-N.png b/openzwave/images/cooper/RF9540-N.png new file mode 100644 index 00000000..20c27c01 Binary files /dev/null and b/openzwave/images/cooper/RF9540-N.png differ diff --git a/openzwave/images/cooper/RF9542-Z.png b/openzwave/images/cooper/RF9542-Z.png new file mode 100644 index 00000000..8515eba8 Binary files /dev/null and b/openzwave/images/cooper/RF9542-Z.png differ diff --git a/openzwave/images/cooper/rf9534.png b/openzwave/images/cooper/rf9534.png new file mode 100644 index 00000000..b36d532a Binary files /dev/null and b/openzwave/images/cooper/rf9534.png differ diff --git a/openzwave/images/danfoss/living.png b/openzwave/images/danfoss/living.png new file mode 100644 index 00000000..b6d475bb Binary files /dev/null and b/openzwave/images/danfoss/living.png differ diff --git a/openzwave/images/danfoss/rsroom.png b/openzwave/images/danfoss/rsroom.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/danfoss/rsroom.png differ diff --git a/openzwave/images/danfoss/z.png b/openzwave/images/danfoss/z.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/danfoss/z.png differ diff --git a/openzwave/images/devolo/mt02648.png b/openzwave/images/devolo/mt02648.png new file mode 100644 index 00000000..75d01c95 Binary files /dev/null and b/openzwave/images/devolo/mt02648.png differ diff --git a/openzwave/images/devolo/mt02755.png b/openzwave/images/devolo/mt02755.png new file mode 100644 index 00000000..7f3c15e1 Binary files /dev/null and b/openzwave/images/devolo/mt02755.png differ diff --git a/openzwave/images/devolo/mt02758.png b/openzwave/images/devolo/mt02758.png new file mode 100644 index 00000000..82ca914b Binary files /dev/null and b/openzwave/images/devolo/mt02758.png differ diff --git a/openzwave/images/devolo/mt2646.png b/openzwave/images/devolo/mt2646.png new file mode 100644 index 00000000..8f5e3c5a Binary files /dev/null and b/openzwave/images/devolo/mt2646.png differ diff --git a/openzwave/images/devolo/mt2647.png b/openzwave/images/devolo/mt2647.png new file mode 100644 index 00000000..4069fabd Binary files /dev/null and b/openzwave/images/devolo/mt2647.png differ diff --git a/openzwave/images/devolo/mt2652.png b/openzwave/images/devolo/mt2652.png new file mode 100644 index 00000000..91eedc2a Binary files /dev/null and b/openzwave/images/devolo/mt2652.png differ diff --git a/openzwave/images/devolo/mt2756.png b/openzwave/images/devolo/mt2756.png new file mode 100644 index 00000000..77601e8b Binary files /dev/null and b/openzwave/images/devolo/mt2756.png differ diff --git a/openzwave/images/devolo/mt2759.png b/openzwave/images/devolo/mt2759.png new file mode 100644 index 00000000..58bd4a66 Binary files /dev/null and b/openzwave/images/devolo/mt2759.png differ diff --git a/openzwave/images/devolo/mt2760.png b/openzwave/images/devolo/mt2760.png new file mode 100644 index 00000000..58bd4a66 Binary files /dev/null and b/openzwave/images/devolo/mt2760.png differ diff --git a/openzwave/images/devolo/mt2761.png b/openzwave/images/devolo/mt2761.png new file mode 100644 index 00000000..58bd4a66 Binary files /dev/null and b/openzwave/images/devolo/mt2761.png differ diff --git a/openzwave/images/diehlcontrols/766366.png b/openzwave/images/diehlcontrols/766366.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/diehlcontrols/766366.png differ diff --git a/openzwave/images/dlink/dch-z110.png b/openzwave/images/dlink/dch-z110.png new file mode 100644 index 00000000..f75f424f Binary files /dev/null and b/openzwave/images/dlink/dch-z110.png differ diff --git a/openzwave/images/dlink/dch-z120.png b/openzwave/images/dlink/dch-z120.png new file mode 100644 index 00000000..4a0a2db9 Binary files /dev/null and b/openzwave/images/dlink/dch-z120.png differ diff --git a/openzwave/images/dlink/dch-z210.png b/openzwave/images/dlink/dch-z210.png new file mode 100644 index 00000000..9093fdf9 Binary files /dev/null and b/openzwave/images/dlink/dch-z210.png differ diff --git a/openzwave/images/dlink/dch-z510.png b/openzwave/images/dlink/dch-z510.png new file mode 100644 index 00000000..d3b2dead Binary files /dev/null and b/openzwave/images/dlink/dch-z510.png differ diff --git a/openzwave/images/dome/0002.png b/openzwave/images/dome/0002.png new file mode 100644 index 00000000..30a1bcd4 Binary files /dev/null and b/openzwave/images/dome/0002.png differ diff --git a/openzwave/images/dome/0085.png b/openzwave/images/dome/0085.png new file mode 100644 index 00000000..f24bd816 Binary files /dev/null and b/openzwave/images/dome/0085.png differ diff --git a/openzwave/images/dome/0086.png b/openzwave/images/dome/0086.png new file mode 100644 index 00000000..d2061918 Binary files /dev/null and b/openzwave/images/dome/0086.png differ diff --git a/openzwave/images/dome/0088.png b/openzwave/images/dome/0088.png new file mode 100644 index 00000000..1fbd88af Binary files /dev/null and b/openzwave/images/dome/0088.png differ diff --git a/openzwave/images/dome/0201.png b/openzwave/images/dome/0201.png new file mode 100644 index 00000000..bfb8f64b Binary files /dev/null and b/openzwave/images/dome/0201.png differ diff --git a/openzwave/images/dome/dmex1.png b/openzwave/images/dome/dmex1.png new file mode 100644 index 00000000..f5536b7a Binary files /dev/null and b/openzwave/images/dome/dmex1.png differ diff --git a/openzwave/images/domitech/zb22uk.png b/openzwave/images/domitech/zb22uk.png new file mode 100644 index 00000000..d401f1a2 Binary files /dev/null and b/openzwave/images/domitech/zb22uk.png differ diff --git a/openzwave/images/domitech/ze27eu.png b/openzwave/images/domitech/ze27eu.png new file mode 100644 index 00000000..442dbfc0 Binary files /dev/null and b/openzwave/images/domitech/ze27eu.png differ diff --git a/openzwave/images/dragontech/wd-100.png b/openzwave/images/dragontech/wd-100.png new file mode 100644 index 00000000..37785fde Binary files /dev/null and b/openzwave/images/dragontech/wd-100.png differ diff --git a/openzwave/images/duwi/ZWES1000.png b/openzwave/images/duwi/ZWES1000.png new file mode 100644 index 00000000..74847b8a Binary files /dev/null and b/openzwave/images/duwi/ZWES1000.png differ diff --git a/openzwave/images/duwi/zw-edan-300.png b/openzwave/images/duwi/zw-edan-300.png new file mode 100644 index 00000000..74847b8a Binary files /dev/null and b/openzwave/images/duwi/zw-edan-300.png differ diff --git a/openzwave/images/duwi/zw-zdan-300.png b/openzwave/images/duwi/zw-zdan-300.png new file mode 100644 index 00000000..5ba9bd15 Binary files /dev/null and b/openzwave/images/duwi/zw-zdan-300.png differ diff --git a/openzwave/images/duwi/zwws.png b/openzwave/images/duwi/zwws.png new file mode 100644 index 00000000..b9df26d1 Binary files /dev/null and b/openzwave/images/duwi/zwws.png differ diff --git a/openzwave/images/ecodim/0.7.jpg b/openzwave/images/ecodim/0.7.jpg new file mode 100644 index 00000000..59893ce1 Binary files /dev/null and b/openzwave/images/ecodim/0.7.jpg differ diff --git a/openzwave/images/ecolink/doorwindow.png b/openzwave/images/ecolink/doorwindow.png new file mode 100644 index 00000000..a546a9ec Binary files /dev/null and b/openzwave/images/ecolink/doorwindow.png differ diff --git a/openzwave/images/ecolink/firefighter.png b/openzwave/images/ecolink/firefighter.png new file mode 100644 index 00000000..0840787f Binary files /dev/null and b/openzwave/images/ecolink/firefighter.png differ diff --git a/openzwave/images/ecolink/floodfreeze.png b/openzwave/images/ecolink/floodfreeze.png new file mode 100644 index 00000000..cba2e2ef Binary files /dev/null and b/openzwave/images/ecolink/floodfreeze.png differ diff --git a/openzwave/images/ecolink/motion.png b/openzwave/images/ecolink/motion.png new file mode 100644 index 00000000..9e9ac459 Binary files /dev/null and b/openzwave/images/ecolink/motion.png differ diff --git a/openzwave/images/ecolink/sensor.png b/openzwave/images/ecolink/sensor.png new file mode 100644 index 00000000..53e42a1c Binary files /dev/null and b/openzwave/images/ecolink/sensor.png differ diff --git a/openzwave/images/ecolink/tiltsensor.png b/openzwave/images/ecolink/tiltsensor.png new file mode 100644 index 00000000..a020a35b Binary files /dev/null and b/openzwave/images/ecolink/tiltsensor.png differ diff --git a/openzwave/images/econet/ezw1204.png b/openzwave/images/econet/ezw1204.png new file mode 100644 index 00000000..673703e8 Binary files /dev/null and b/openzwave/images/econet/ezw1204.png differ diff --git a/openzwave/images/electronicsolutions/dbmz.png b/openzwave/images/electronicsolutions/dbmz.png new file mode 100644 index 00000000..e67a8f2d Binary files /dev/null and b/openzwave/images/electronicsolutions/dbmz.png differ diff --git a/openzwave/images/enblink/ss201-us-w_1308.png b/openzwave/images/enblink/ss201-us-w_1308.png new file mode 100644 index 00000000..12d708e2 Binary files /dev/null and b/openzwave/images/enblink/ss201-us-w_1308.png differ diff --git a/openzwave/images/enerwave/zw15rmplus.png b/openzwave/images/enerwave/zw15rmplus.png new file mode 100644 index 00000000..5d9f0005 Binary files /dev/null and b/openzwave/images/enerwave/zw15rmplus.png differ diff --git a/openzwave/images/enerwave/zw20r.png b/openzwave/images/enerwave/zw20r.png new file mode 100644 index 00000000..ce2b0271 Binary files /dev/null and b/openzwave/images/enerwave/zw20r.png differ diff --git a/openzwave/images/enerwave/zw20rm.png b/openzwave/images/enerwave/zw20rm.png new file mode 100644 index 00000000..659b4459 Binary files /dev/null and b/openzwave/images/enerwave/zw20rm.png differ diff --git a/openzwave/images/enerwave/zwn-bpc.png b/openzwave/images/enerwave/zwn-bpc.png new file mode 100644 index 00000000..87caa325 Binary files /dev/null and b/openzwave/images/enerwave/zwn-bpc.png differ diff --git a/openzwave/images/enerwave/zwnrsm1plus.png b/openzwave/images/enerwave/zwnrsm1plus.png new file mode 100644 index 00000000..6172bc11 Binary files /dev/null and b/openzwave/images/enerwave/zwnrsm1plus.png differ diff --git a/openzwave/images/enerwave/zwnrsm2plus.png b/openzwave/images/enerwave/zwnrsm2plus.png new file mode 100644 index 00000000..5eaff109 Binary files /dev/null and b/openzwave/images/enerwave/zwnrsm2plus.png differ diff --git a/openzwave/images/eurotronic/eur_airquality.png b/openzwave/images/eurotronic/eur_airquality.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/eurotronic/eur_airquality.png differ diff --git a/openzwave/images/eurotronic/eur_cometz.png b/openzwave/images/eurotronic/eur_cometz.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/eurotronic/eur_cometz.png differ diff --git a/openzwave/images/eurotronic/eur_spiritz.png b/openzwave/images/eurotronic/eur_spiritz.png new file mode 100644 index 00000000..f150486d Binary files /dev/null and b/openzwave/images/eurotronic/eur_spiritz.png differ diff --git a/openzwave/images/eurotronic/eur_stellaz.png b/openzwave/images/eurotronic/eur_stellaz.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/eurotronic/eur_stellaz.png differ diff --git a/openzwave/images/eurotronic/eur_temphumid.png b/openzwave/images/eurotronic/eur_temphumid.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/eurotronic/eur_temphumid.png differ diff --git a/openzwave/images/everspring/ad146.png b/openzwave/images/everspring/ad146.png new file mode 100644 index 00000000..09eaabfd Binary files /dev/null and b/openzwave/images/everspring/ad146.png differ diff --git a/openzwave/images/everspring/ad147.png b/openzwave/images/everspring/ad147.png new file mode 100644 index 00000000..dbe59ab7 Binary files /dev/null and b/openzwave/images/everspring/ad147.png differ diff --git a/openzwave/images/everspring/an157.png b/openzwave/images/everspring/an157.png new file mode 100644 index 00000000..61f3d205 Binary files /dev/null and b/openzwave/images/everspring/an157.png differ diff --git a/openzwave/images/everspring/an158.png b/openzwave/images/everspring/an158.png new file mode 100644 index 00000000..a2e44561 Binary files /dev/null and b/openzwave/images/everspring/an158.png differ diff --git a/openzwave/images/everspring/an163.png b/openzwave/images/everspring/an163.png new file mode 100644 index 00000000..8b987cbc Binary files /dev/null and b/openzwave/images/everspring/an163.png differ diff --git a/openzwave/images/everspring/an179.png b/openzwave/images/everspring/an179.png new file mode 100644 index 00000000..242097e0 Binary files /dev/null and b/openzwave/images/everspring/an179.png differ diff --git a/openzwave/images/everspring/an180.png b/openzwave/images/everspring/an180.png new file mode 100644 index 00000000..dbe59ab7 Binary files /dev/null and b/openzwave/images/everspring/an180.png differ diff --git a/openzwave/images/everspring/an181.png b/openzwave/images/everspring/an181.png new file mode 100644 index 00000000..526604cf Binary files /dev/null and b/openzwave/images/everspring/an181.png differ diff --git a/openzwave/images/everspring/hac01.png b/openzwave/images/everspring/hac01.png new file mode 100644 index 00000000..4ad73178 Binary files /dev/null and b/openzwave/images/everspring/hac01.png differ diff --git a/openzwave/images/everspring/han01.png b/openzwave/images/everspring/han01.png new file mode 100644 index 00000000..6e8a8e49 Binary files /dev/null and b/openzwave/images/everspring/han01.png differ diff --git a/openzwave/images/everspring/han02-1.png b/openzwave/images/everspring/han02-1.png new file mode 100644 index 00000000..eae22593 Binary files /dev/null and b/openzwave/images/everspring/han02-1.png differ diff --git a/openzwave/images/everspring/hsm02.png b/openzwave/images/everspring/hsm02.png new file mode 100644 index 00000000..00e879a0 Binary files /dev/null and b/openzwave/images/everspring/hsm02.png differ diff --git a/openzwave/images/everspring/hsp02.png b/openzwave/images/everspring/hsp02.png new file mode 100644 index 00000000..acb88b10 Binary files /dev/null and b/openzwave/images/everspring/hsp02.png differ diff --git a/openzwave/images/everspring/lptdm1u.png b/openzwave/images/everspring/lptdm1u.png new file mode 100644 index 00000000..79714bc1 Binary files /dev/null and b/openzwave/images/everspring/lptdm1u.png differ diff --git a/openzwave/images/everspring/se812.png b/openzwave/images/everspring/se812.png new file mode 100644 index 00000000..84cdbb04 Binary files /dev/null and b/openzwave/images/everspring/se812.png differ diff --git a/openzwave/images/everspring/sf812.png b/openzwave/images/everspring/sf812.png new file mode 100644 index 00000000..5334ca99 Binary files /dev/null and b/openzwave/images/everspring/sf812.png differ diff --git a/openzwave/images/everspring/sm103.png b/openzwave/images/everspring/sm103.png new file mode 100644 index 00000000..099e5f10 Binary files /dev/null and b/openzwave/images/everspring/sm103.png differ diff --git a/openzwave/images/everspring/sp103.png b/openzwave/images/everspring/sp103.png new file mode 100644 index 00000000..f340b0f6 Binary files /dev/null and b/openzwave/images/everspring/sp103.png differ diff --git a/openzwave/images/everspring/sp814.png b/openzwave/images/everspring/sp814.png new file mode 100644 index 00000000..e23201d9 Binary files /dev/null and b/openzwave/images/everspring/sp814.png differ diff --git a/openzwave/images/everspring/sp815.png b/openzwave/images/everspring/sp815.png new file mode 100644 index 00000000..e6e9afd7 Binary files /dev/null and b/openzwave/images/everspring/sp815.png differ diff --git a/openzwave/images/everspring/sp816.png b/openzwave/images/everspring/sp816.png new file mode 100644 index 00000000..9923615d Binary files /dev/null and b/openzwave/images/everspring/sp816.png differ diff --git a/openzwave/images/everspring/st812.png b/openzwave/images/everspring/st812.png new file mode 100644 index 00000000..44194e3d Binary files /dev/null and b/openzwave/images/everspring/st812.png differ diff --git a/openzwave/images/everspring/st814.png b/openzwave/images/everspring/st814.png new file mode 100644 index 00000000..7a1c2023 Binary files /dev/null and b/openzwave/images/everspring/st814.png differ diff --git a/openzwave/images/everspring/st815.png b/openzwave/images/everspring/st815.png new file mode 100644 index 00000000..3ea18b71 Binary files /dev/null and b/openzwave/images/everspring/st815.png differ diff --git a/openzwave/images/everspring/tse03.png b/openzwave/images/everspring/tse03.png new file mode 100644 index 00000000..fe4b50d5 Binary files /dev/null and b/openzwave/images/everspring/tse03.png differ diff --git a/openzwave/images/evolve/lfm-20.png b/openzwave/images/evolve/lfm-20.png new file mode 100644 index 00000000..4389a6a2 Binary files /dev/null and b/openzwave/images/evolve/lfm-20.png differ diff --git a/openzwave/images/evolve/ltm-5.png b/openzwave/images/evolve/ltm-5.png new file mode 100644 index 00000000..07a02628 Binary files /dev/null and b/openzwave/images/evolve/ltm-5.png differ diff --git a/openzwave/images/fakro/arz.png b/openzwave/images/fakro/arz.png new file mode 100644 index 00000000..1d6be6fd Binary files /dev/null and b/openzwave/images/fakro/arz.png differ diff --git a/openzwave/images/fakro/zws12.png b/openzwave/images/fakro/zws12.png new file mode 100644 index 00000000..1e0af3bf Binary files /dev/null and b/openzwave/images/fakro/zws12.png differ diff --git a/openzwave/images/fibaro/fgbs222.png b/openzwave/images/fibaro/fgbs222.png new file mode 100644 index 00000000..77dc0c80 Binary files /dev/null and b/openzwave/images/fibaro/fgbs222.png differ diff --git a/openzwave/images/fibaro/fgcd001.png b/openzwave/images/fibaro/fgcd001.png new file mode 100644 index 00000000..0fa6219f Binary files /dev/null and b/openzwave/images/fibaro/fgcd001.png differ diff --git a/openzwave/images/fibaro/fgd212.png b/openzwave/images/fibaro/fgd212.png new file mode 100644 index 00000000..01e43ddc Binary files /dev/null and b/openzwave/images/fibaro/fgd212.png differ diff --git a/openzwave/images/fibaro/fgdw2.png b/openzwave/images/fibaro/fgdw2.png new file mode 100644 index 00000000..6f3d3343 Binary files /dev/null and b/openzwave/images/fibaro/fgdw2.png differ diff --git a/openzwave/images/fibaro/fgfs101zw5.png b/openzwave/images/fibaro/fgfs101zw5.png new file mode 100644 index 00000000..37e62f80 Binary files /dev/null and b/openzwave/images/fibaro/fgfs101zw5.png differ diff --git a/openzwave/images/fibaro/fggc001.png b/openzwave/images/fibaro/fggc001.png new file mode 100644 index 00000000..d32c04bd Binary files /dev/null and b/openzwave/images/fibaro/fggc001.png differ diff --git a/openzwave/images/fibaro/fgk001.png b/openzwave/images/fibaro/fgk001.png new file mode 100644 index 00000000..4c01619b Binary files /dev/null and b/openzwave/images/fibaro/fgk001.png differ diff --git a/openzwave/images/fibaro/fgk10x.png b/openzwave/images/fibaro/fgk10x.png new file mode 100644 index 00000000..e6508e08 Binary files /dev/null and b/openzwave/images/fibaro/fgk10x.png differ diff --git a/openzwave/images/fibaro/fgkf601.png b/openzwave/images/fibaro/fgkf601.png new file mode 100644 index 00000000..9a8b8595 Binary files /dev/null and b/openzwave/images/fibaro/fgkf601.png differ diff --git a/openzwave/images/fibaro/fgms.png b/openzwave/images/fibaro/fgms.png new file mode 100644 index 00000000..79ea33ae Binary files /dev/null and b/openzwave/images/fibaro/fgms.png differ diff --git a/openzwave/images/fibaro/fgmszw5.png b/openzwave/images/fibaro/fgmszw5.png new file mode 100644 index 00000000..181a2553 Binary files /dev/null and b/openzwave/images/fibaro/fgmszw5.png differ diff --git a/openzwave/images/fibaro/fgpb101.png b/openzwave/images/fibaro/fgpb101.png new file mode 100644 index 00000000..f934680a Binary files /dev/null and b/openzwave/images/fibaro/fgpb101.png differ diff --git a/openzwave/images/fibaro/fgr223.png b/openzwave/images/fibaro/fgr223.png new file mode 100644 index 00000000..c1c7629b Binary files /dev/null and b/openzwave/images/fibaro/fgr223.png differ diff --git a/openzwave/images/fibaro/fgrgbw442.png b/openzwave/images/fibaro/fgrgbw442.png new file mode 100644 index 00000000..83011348 Binary files /dev/null and b/openzwave/images/fibaro/fgrgbw442.png differ diff --git a/openzwave/images/fibaro/fgrgbwm441.png b/openzwave/images/fibaro/fgrgbwm441.png new file mode 100644 index 00000000..1e1dce62 Binary files /dev/null and b/openzwave/images/fibaro/fgrgbwm441.png differ diff --git a/openzwave/images/fibaro/fgs213.png b/openzwave/images/fibaro/fgs213.png new file mode 100644 index 00000000..4e7810ee Binary files /dev/null and b/openzwave/images/fibaro/fgs213.png differ diff --git a/openzwave/images/fibaro/fgs223.png b/openzwave/images/fibaro/fgs223.png new file mode 100644 index 00000000..4afcf393 Binary files /dev/null and b/openzwave/images/fibaro/fgs223.png differ diff --git a/openzwave/images/fibaro/fgs224.png b/openzwave/images/fibaro/fgs224.png new file mode 100644 index 00000000..efd39acc Binary files /dev/null and b/openzwave/images/fibaro/fgs224.png differ diff --git a/openzwave/images/fibaro/fgsd002.png b/openzwave/images/fibaro/fgsd002.png new file mode 100644 index 00000000..6ef9bbde Binary files /dev/null and b/openzwave/images/fibaro/fgsd002.png differ diff --git a/openzwave/images/fibaro/fgt001.png b/openzwave/images/fibaro/fgt001.png new file mode 100644 index 00000000..3f66a12c Binary files /dev/null and b/openzwave/images/fibaro/fgt001.png differ diff --git a/openzwave/images/fibaro/fgwd111.png b/openzwave/images/fibaro/fgwd111.png new file mode 100644 index 00000000..b353a48e Binary files /dev/null and b/openzwave/images/fibaro/fgwd111.png differ diff --git a/openzwave/images/fibaro/fgwds221.png b/openzwave/images/fibaro/fgwds221.png new file mode 100644 index 00000000..1704a6f0 Binary files /dev/null and b/openzwave/images/fibaro/fgwds221.png differ diff --git a/openzwave/images/fibaro/fgwoe.png b/openzwave/images/fibaro/fgwoe.png new file mode 100644 index 00000000..f31bc499 Binary files /dev/null and b/openzwave/images/fibaro/fgwoe.png differ diff --git a/openzwave/images/fibaro/fgwpe.png b/openzwave/images/fibaro/fgwpe.png new file mode 100644 index 00000000..7248a5cf Binary files /dev/null and b/openzwave/images/fibaro/fgwpe.png differ diff --git a/openzwave/images/fibaro/fgwpfzw5.png b/openzwave/images/fibaro/fgwpfzw5.png new file mode 100644 index 00000000..5e71cf77 Binary files /dev/null and b/openzwave/images/fibaro/fgwpfzw5.png differ diff --git a/openzwave/images/fibaro/fgwpg111.png b/openzwave/images/fibaro/fgwpg111.png new file mode 100644 index 00000000..1263fdc0 Binary files /dev/null and b/openzwave/images/fibaro/fgwpg111.png differ diff --git a/openzwave/images/fibaro/fgwr111.png b/openzwave/images/fibaro/fgwr111.png new file mode 100644 index 00000000..90367356 Binary files /dev/null and b/openzwave/images/fibaro/fgwr111.png differ diff --git a/openzwave/images/firstalert/zcombo-g.png b/openzwave/images/firstalert/zcombo-g.png new file mode 100644 index 00000000..7ca9d478 Binary files /dev/null and b/openzwave/images/firstalert/zcombo-g.png differ diff --git a/openzwave/images/firstalert/zcombo.png b/openzwave/images/firstalert/zcombo.png new file mode 100644 index 00000000..83b036af Binary files /dev/null and b/openzwave/images/firstalert/zcombo.png differ diff --git a/openzwave/images/firstalert/zsmoke.png b/openzwave/images/firstalert/zsmoke.png new file mode 100644 index 00000000..fd13cc7b Binary files /dev/null and b/openzwave/images/firstalert/zsmoke.png differ diff --git a/openzwave/images/followgood/swz-1002.png b/openzwave/images/followgood/swz-1002.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/followgood/swz-1002.png differ diff --git a/openzwave/images/forest/fs2z5232000002.png b/openzwave/images/forest/fs2z5232000002.png new file mode 100644 index 00000000..7e9bccd6 Binary files /dev/null and b/openzwave/images/forest/fs2z5232000002.png differ diff --git a/openzwave/images/fortrezz/fmi.png b/openzwave/images/fortrezz/fmi.png new file mode 100644 index 00000000..a256a242 Binary files /dev/null and b/openzwave/images/fortrezz/fmi.png differ diff --git a/openzwave/images/fortrezz/fts05p.png b/openzwave/images/fortrezz/fts05p.png new file mode 100644 index 00000000..632775c8 Binary files /dev/null and b/openzwave/images/fortrezz/fts05p.png differ diff --git a/openzwave/images/fortrezz/gdc1_fortrezz_1501.png b/openzwave/images/fortrezz/gdc1_fortrezz_1501.png new file mode 100644 index 00000000..67faf3ce Binary files /dev/null and b/openzwave/images/fortrezz/gdc1_fortrezz_1501.png differ diff --git a/openzwave/images/fortrezz/mimo2plus.png b/openzwave/images/fortrezz/mimo2plus.png new file mode 100644 index 00000000..96cac59d Binary files /dev/null and b/openzwave/images/fortrezz/mimo2plus.png differ diff --git a/openzwave/images/fortrezz/mimolite.png b/openzwave/images/fortrezz/mimolite.png new file mode 100644 index 00000000..0caf04c8 Binary files /dev/null and b/openzwave/images/fortrezz/mimolite.png differ diff --git a/openzwave/images/fortrezz/ssa2.png b/openzwave/images/fortrezz/ssa2.png new file mode 100644 index 00000000..8e402f5a Binary files /dev/null and b/openzwave/images/fortrezz/ssa2.png differ diff --git a/openzwave/images/fortrezz/ssa3.png b/openzwave/images/fortrezz/ssa3.png new file mode 100644 index 00000000..cbbfc62c Binary files /dev/null and b/openzwave/images/fortrezz/ssa3.png differ diff --git a/openzwave/images/fortrezz/wv01.png b/openzwave/images/fortrezz/wv01.png new file mode 100644 index 00000000..5d531e39 Binary files /dev/null and b/openzwave/images/fortrezz/wv01.png differ diff --git a/openzwave/images/fortrezz/wwa-01aa.png b/openzwave/images/fortrezz/wwa-01aa.png new file mode 100644 index 00000000..c065944b Binary files /dev/null and b/openzwave/images/fortrezz/wwa-01aa.png differ diff --git a/openzwave/images/fortrezz/wwa02.png b/openzwave/images/fortrezz/wwa02.png new file mode 100644 index 00000000..c065944b Binary files /dev/null and b/openzwave/images/fortrezz/wwa02.png differ diff --git a/openzwave/images/frostdale/fdn2311.png b/openzwave/images/frostdale/fdn2311.png new file mode 100644 index 00000000..6dabd34d Binary files /dev/null and b/openzwave/images/frostdale/fdn2311.png differ diff --git a/openzwave/images/ge/12719-plugin-switch.png b/openzwave/images/ge/12719-plugin-switch.png new file mode 100644 index 00000000..26b9ffea Binary files /dev/null and b/openzwave/images/ge/12719-plugin-switch.png differ diff --git a/openzwave/images/ge/12724-dimmer.png b/openzwave/images/ge/12724-dimmer.png new file mode 100644 index 00000000..4057005a Binary files /dev/null and b/openzwave/images/ge/12724-dimmer.png differ diff --git a/openzwave/images/ge/12727.png b/openzwave/images/ge/12727.png new file mode 100644 index 00000000..97dbb719 Binary files /dev/null and b/openzwave/images/ge/12727.png differ diff --git a/openzwave/images/ge/14280-plugin-dimmer.png b/openzwave/images/ge/14280-plugin-dimmer.png new file mode 100644 index 00000000..f51b7d1a Binary files /dev/null and b/openzwave/images/ge/14280-plugin-dimmer.png differ diff --git a/openzwave/images/ge/14282-plugin-switch.png b/openzwave/images/ge/14282-plugin-switch.png new file mode 100644 index 00000000..1a62ea67 Binary files /dev/null and b/openzwave/images/ge/14282-plugin-switch.png differ diff --git a/openzwave/images/ge/14284.png b/openzwave/images/ge/14284.png new file mode 100644 index 00000000..aff35b06 Binary files /dev/null and b/openzwave/images/ge/14284.png differ diff --git a/openzwave/images/ge/14285.png b/openzwave/images/ge/14285.png new file mode 100644 index 00000000..b7624069 Binary files /dev/null and b/openzwave/images/ge/14285.png differ diff --git a/openzwave/images/ge/14288-outlet.png b/openzwave/images/ge/14288-outlet.png new file mode 100644 index 00000000..46d3ca93 Binary files /dev/null and b/openzwave/images/ge/14288-outlet.png differ diff --git a/openzwave/images/ge/14291-switch.png b/openzwave/images/ge/14291-switch.png new file mode 100644 index 00000000..780264fa Binary files /dev/null and b/openzwave/images/ge/14291-switch.png differ diff --git a/openzwave/images/ge/14292-toggle-switch.png b/openzwave/images/ge/14292-toggle-switch.png new file mode 100644 index 00000000..569d9d0a Binary files /dev/null and b/openzwave/images/ge/14292-toggle-switch.png differ diff --git a/openzwave/images/ge/14294-dimmer.png b/openzwave/images/ge/14294-dimmer.png new file mode 100644 index 00000000..d50afdbc Binary files /dev/null and b/openzwave/images/ge/14294-dimmer.png differ diff --git a/openzwave/images/ge/14295-dimmer-toggle.png b/openzwave/images/ge/14295-dimmer-toggle.png new file mode 100644 index 00000000..9a36a694 Binary files /dev/null and b/openzwave/images/ge/14295-dimmer-toggle.png differ diff --git a/openzwave/images/ge/14298.png b/openzwave/images/ge/14298.png new file mode 100644 index 00000000..0958f7f1 Binary files /dev/null and b/openzwave/images/ge/14298.png differ diff --git a/openzwave/images/ge/26931-motion-switch.png b/openzwave/images/ge/26931-motion-switch.png new file mode 100644 index 00000000..8c0eec35 Binary files /dev/null and b/openzwave/images/ge/26931-motion-switch.png differ diff --git a/openzwave/images/ge/26933-motion-dimmer.png b/openzwave/images/ge/26933-motion-dimmer.png new file mode 100644 index 00000000..751c7cfa Binary files /dev/null and b/openzwave/images/ge/26933-motion-dimmer.png differ diff --git a/openzwave/images/ge/28167-plugin-dimmer.png b/openzwave/images/ge/28167-plugin-dimmer.png new file mode 100644 index 00000000..49fc1984 Binary files /dev/null and b/openzwave/images/ge/28167-plugin-dimmer.png differ diff --git a/openzwave/images/ge/28169-plugin-switch.png b/openzwave/images/ge/28169-plugin-switch.png new file mode 100644 index 00000000..c4157ca2 Binary files /dev/null and b/openzwave/images/ge/28169-plugin-switch.png differ diff --git a/openzwave/images/ge/45604.png b/openzwave/images/ge/45604.png new file mode 100644 index 00000000..590a332f Binary files /dev/null and b/openzwave/images/ge/45604.png differ diff --git a/openzwave/images/ge/46201-switch.png b/openzwave/images/ge/46201-switch.png new file mode 100644 index 00000000..87010712 Binary files /dev/null and b/openzwave/images/ge/46201-switch.png differ diff --git a/openzwave/images/ge/46202-switch.png b/openzwave/images/ge/46202-switch.png new file mode 100644 index 00000000..64e6b762 Binary files /dev/null and b/openzwave/images/ge/46202-switch.png differ diff --git a/openzwave/images/ge/46203-dimmer.png b/openzwave/images/ge/46203-dimmer.png new file mode 100644 index 00000000..c0a65037 Binary files /dev/null and b/openzwave/images/ge/46203-dimmer.png differ diff --git a/openzwave/images/ge/46204-dimmer-toggle.png b/openzwave/images/ge/46204-dimmer-toggle.png new file mode 100644 index 00000000..016c679a Binary files /dev/null and b/openzwave/images/ge/46204-dimmer-toggle.png differ diff --git a/openzwave/images/ge/dimmer.png b/openzwave/images/ge/dimmer.png new file mode 100644 index 00000000..70ce5f31 Binary files /dev/null and b/openzwave/images/ge/dimmer.png differ diff --git a/openzwave/images/ge/dimmer_module.png b/openzwave/images/ge/dimmer_module.png new file mode 100644 index 00000000..26b9ffea Binary files /dev/null and b/openzwave/images/ge/dimmer_module.png differ diff --git a/openzwave/images/ge/hinge-pin.png b/openzwave/images/ge/hinge-pin.png new file mode 100644 index 00000000..aea76974 Binary files /dev/null and b/openzwave/images/ge/hinge-pin.png differ diff --git a/openzwave/images/ge/receptacle.png b/openzwave/images/ge/receptacle.png new file mode 100644 index 00000000..46d3ca93 Binary files /dev/null and b/openzwave/images/ge/receptacle.png differ diff --git a/openzwave/images/ge/relay.png b/openzwave/images/ge/relay.png new file mode 100644 index 00000000..97dbb719 Binary files /dev/null and b/openzwave/images/ge/relay.png differ diff --git a/openzwave/images/ge/ze26i.png b/openzwave/images/ge/ze26i.png new file mode 100644 index 00000000..0be0494e Binary files /dev/null and b/openzwave/images/ge/ze26i.png differ diff --git a/openzwave/images/ge/zw6302.png b/openzwave/images/ge/zw6302.png new file mode 100644 index 00000000..d47c187c Binary files /dev/null and b/openzwave/images/ge/zw6302.png differ diff --git a/openzwave/images/goodway/td14010.png b/openzwave/images/goodway/td14010.png new file mode 100644 index 00000000..dd4e818f Binary files /dev/null and b/openzwave/images/goodway/td14010.png differ diff --git a/openzwave/images/gr/gr-302n.png b/openzwave/images/gr/gr-302n.png new file mode 100644 index 00000000..dc316ec5 Binary files /dev/null and b/openzwave/images/gr/gr-302n.png differ diff --git a/openzwave/images/gr/gr105.png b/openzwave/images/gr/gr105.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/gr/gr105.png differ diff --git a/openzwave/images/gr/gr105n.png b/openzwave/images/gr/gr105n.png new file mode 100644 index 00000000..30a1bcd4 Binary files /dev/null and b/openzwave/images/gr/gr105n.png differ diff --git a/openzwave/images/graber/brz1.png b/openzwave/images/graber/brz1.png new file mode 100644 index 00000000..bf272cc6 Binary files /dev/null and b/openzwave/images/graber/brz1.png differ diff --git a/openzwave/images/graber/csz1.png b/openzwave/images/graber/csz1.png new file mode 100644 index 00000000..bf272cc6 Binary files /dev/null and b/openzwave/images/graber/csz1.png differ diff --git a/openzwave/images/graber/mcz1.png b/openzwave/images/graber/mcz1.png new file mode 100644 index 00000000..52338e49 Binary files /dev/null and b/openzwave/images/graber/mcz1.png differ diff --git a/openzwave/images/graber/rsz1.png b/openzwave/images/graber/rsz1.png new file mode 100644 index 00000000..bf272cc6 Binary files /dev/null and b/openzwave/images/graber/rsz1.png differ diff --git a/openzwave/images/graber/vcz1.png b/openzwave/images/graber/vcz1.png new file mode 100644 index 00000000..bf272cc6 Binary files /dev/null and b/openzwave/images/graber/vcz1.png differ diff --git a/openzwave/images/greenwave/gs1110-1-gr-1.png b/openzwave/images/greenwave/gs1110-1-gr-1.png new file mode 100644 index 00000000..2d878ab5 Binary files /dev/null and b/openzwave/images/greenwave/gs1110-1-gr-1.png differ diff --git a/openzwave/images/greenwave/powernode1.png b/openzwave/images/greenwave/powernode1.png new file mode 100644 index 00000000..223738ea Binary files /dev/null and b/openzwave/images/greenwave/powernode1.png differ diff --git a/openzwave/images/greenwave/powernode6.png b/openzwave/images/greenwave/powernode6.png new file mode 100644 index 00000000..6107ebc1 Binary files /dev/null and b/openzwave/images/greenwave/powernode6.png differ diff --git a/openzwave/images/guardtec/gkw2000d.png b/openzwave/images/guardtec/gkw2000d.png new file mode 100644 index 00000000..e003de6e Binary files /dev/null and b/openzwave/images/guardtec/gkw2000d.png differ diff --git a/openzwave/images/hab/iblinds.png b/openzwave/images/hab/iblinds.png new file mode 100644 index 00000000..0f25e3d6 Binary files /dev/null and b/openzwave/images/hab/iblinds.png differ diff --git a/openzwave/images/hab/iblindsV3.png b/openzwave/images/hab/iblindsV3.png new file mode 100644 index 00000000..bcf5a6a1 Binary files /dev/null and b/openzwave/images/hab/iblindsV3.png differ diff --git a/openzwave/images/hank/hkzw-dws01.png b/openzwave/images/hank/hkzw-dws01.png new file mode 100644 index 00000000..bc33783c Binary files /dev/null and b/openzwave/images/hank/hkzw-dws01.png differ diff --git a/openzwave/images/hank/hkzw-fld01.png b/openzwave/images/hank/hkzw-fld01.png new file mode 100644 index 00000000..aa5841cc Binary files /dev/null and b/openzwave/images/hank/hkzw-fld01.png differ diff --git a/openzwave/images/hank/hkzw-ms01.png b/openzwave/images/hank/hkzw-ms01.png new file mode 100644 index 00000000..dbf7604c Binary files /dev/null and b/openzwave/images/hank/hkzw-ms01.png differ diff --git a/openzwave/images/hank/hkzw-ms02-200.png b/openzwave/images/hank/hkzw-ms02-200.png new file mode 100644 index 00000000..7c2788ae Binary files /dev/null and b/openzwave/images/hank/hkzw-ms02-200.png differ diff --git a/openzwave/images/hank/hkzw-rgb01.png b/openzwave/images/hank/hkzw-rgb01.png new file mode 100644 index 00000000..09391ebc Binary files /dev/null and b/openzwave/images/hank/hkzw-rgb01.png differ diff --git a/openzwave/images/hank/hkzw-so01-smartplug.png b/openzwave/images/hank/hkzw-so01-smartplug.png new file mode 100644 index 00000000..f0930ca9 Binary files /dev/null and b/openzwave/images/hank/hkzw-so01-smartplug.png differ diff --git a/openzwave/images/hank/hkzw-so03.png b/openzwave/images/hank/hkzw-so03.png new file mode 100644 index 00000000..191a1662 Binary files /dev/null and b/openzwave/images/hank/hkzw-so03.png differ diff --git a/openzwave/images/hank/hkzw-so05-smartplug.png b/openzwave/images/hank/hkzw-so05-smartplug.png new file mode 100644 index 00000000..3fd0dd9f Binary files /dev/null and b/openzwave/images/hank/hkzw-so05-smartplug.png differ diff --git a/openzwave/images/hank/scenecontroller1.png b/openzwave/images/hank/scenecontroller1.png new file mode 100644 index 00000000..6b66ea12 Binary files /dev/null and b/openzwave/images/hank/scenecontroller1.png differ diff --git a/openzwave/images/hank/scenecontroller4.png b/openzwave/images/hank/scenecontroller4.png new file mode 100644 index 00000000..ea02d0d1 Binary files /dev/null and b/openzwave/images/hank/scenecontroller4.png differ diff --git a/openzwave/images/heiman/HS1CA-Z.png b/openzwave/images/heiman/HS1CA-Z.png new file mode 100644 index 00000000..43cdf327 Binary files /dev/null and b/openzwave/images/heiman/HS1CA-Z.png differ diff --git a/openzwave/images/heiman/HS1CG-Z.png b/openzwave/images/heiman/HS1CG-Z.png new file mode 100644 index 00000000..5a027164 Binary files /dev/null and b/openzwave/images/heiman/HS1CG-Z.png differ diff --git a/openzwave/images/heiman/HS1DS-Z.png b/openzwave/images/heiman/HS1DS-Z.png new file mode 100644 index 00000000..97fcbb82 Binary files /dev/null and b/openzwave/images/heiman/HS1DS-Z.png differ diff --git a/openzwave/images/heiman/HS1HT-Z.png b/openzwave/images/heiman/HS1HT-Z.png new file mode 100644 index 00000000..83b261ce Binary files /dev/null and b/openzwave/images/heiman/HS1HT-Z.png differ diff --git a/openzwave/images/heiman/HS1MS-Z.png b/openzwave/images/heiman/HS1MS-Z.png new file mode 100644 index 00000000..2938c96d Binary files /dev/null and b/openzwave/images/heiman/HS1MS-Z.png differ diff --git a/openzwave/images/heiman/HS1SA-Z.png b/openzwave/images/heiman/HS1SA-Z.png new file mode 100644 index 00000000..9ab0a3bb Binary files /dev/null and b/openzwave/images/heiman/HS1SA-Z.png differ diff --git a/openzwave/images/heiman/HS1WL-Z.png b/openzwave/images/heiman/HS1WL-Z.png new file mode 100644 index 00000000..01721b85 Binary files /dev/null and b/openzwave/images/heiman/HS1WL-Z.png differ diff --git a/openzwave/images/heiman/HS2SK-Z.png b/openzwave/images/heiman/HS2SK-Z.png new file mode 100644 index 00000000..ed3e6ca1 Binary files /dev/null and b/openzwave/images/heiman/HS2SK-Z.png differ diff --git a/openzwave/images/heltun/he-ft01.png b/openzwave/images/heltun/he-ft01.png new file mode 100644 index 00000000..3a38280a Binary files /dev/null and b/openzwave/images/heltun/he-ft01.png differ diff --git a/openzwave/images/heltun/he-ht01.png b/openzwave/images/heltun/he-ht01.png new file mode 100644 index 00000000..f437a231 Binary files /dev/null and b/openzwave/images/heltun/he-ht01.png differ diff --git a/openzwave/images/homeseer/hs-ds100plus.png b/openzwave/images/homeseer/hs-ds100plus.png new file mode 100644 index 00000000..6a717d06 Binary files /dev/null and b/openzwave/images/homeseer/hs-ds100plus.png differ diff --git a/openzwave/images/homeseer/hs-fc200plus.png b/openzwave/images/homeseer/hs-fc200plus.png new file mode 100644 index 00000000..d5daa181 Binary files /dev/null and b/openzwave/images/homeseer/hs-fc200plus.png differ diff --git a/openzwave/images/homeseer/hs-fls100plus.png b/openzwave/images/homeseer/hs-fls100plus.png new file mode 100644 index 00000000..c3b347ad Binary files /dev/null and b/openzwave/images/homeseer/hs-fls100plus.png differ diff --git a/openzwave/images/homeseer/hs-ls100plus.png b/openzwave/images/homeseer/hs-ls100plus.png new file mode 100644 index 00000000..c3342e8b Binary files /dev/null and b/openzwave/images/homeseer/hs-ls100plus.png differ diff --git a/openzwave/images/homeseer/hs-ms100plus.png b/openzwave/images/homeseer/hs-ms100plus.png new file mode 100644 index 00000000..fa712ca6 Binary files /dev/null and b/openzwave/images/homeseer/hs-ms100plus.png differ diff --git a/openzwave/images/homeseer/hs-wd100plus.png b/openzwave/images/homeseer/hs-wd100plus.png new file mode 100644 index 00000000..5cf3db40 Binary files /dev/null and b/openzwave/images/homeseer/hs-wd100plus.png differ diff --git a/openzwave/images/homeseer/hs-wd200plus.png b/openzwave/images/homeseer/hs-wd200plus.png new file mode 100644 index 00000000..5cf3db40 Binary files /dev/null and b/openzwave/images/homeseer/hs-wd200plus.png differ diff --git a/openzwave/images/homeseer/hs-ws100plus.png b/openzwave/images/homeseer/hs-ws100plus.png new file mode 100644 index 00000000..f1bb909d Binary files /dev/null and b/openzwave/images/homeseer/hs-ws100plus.png differ diff --git a/openzwave/images/homeseer/hs-ws200plus.png b/openzwave/images/homeseer/hs-ws200plus.png new file mode 100644 index 00000000..f1bb909d Binary files /dev/null and b/openzwave/images/homeseer/hs-ws200plus.png differ diff --git a/openzwave/images/homeseer/hsm200.png b/openzwave/images/homeseer/hsm200.png new file mode 100644 index 00000000..d41f2d36 Binary files /dev/null and b/openzwave/images/homeseer/hsm200.png differ diff --git a/openzwave/images/honeywell/2681-plugin-dimmer.png b/openzwave/images/honeywell/2681-plugin-dimmer.png new file mode 100644 index 00000000..ac29cab4 Binary files /dev/null and b/openzwave/images/honeywell/2681-plugin-dimmer.png differ diff --git a/openzwave/images/honeywell/3830-zw3107.png b/openzwave/images/honeywell/3830-zw3107.png new file mode 100644 index 00000000..ec335b42 Binary files /dev/null and b/openzwave/images/honeywell/3830-zw3107.png differ diff --git a/openzwave/images/honeywell/39348-ZW4005.png b/openzwave/images/honeywell/39348-ZW4005.png new file mode 100644 index 00000000..ea966f93 Binary files /dev/null and b/openzwave/images/honeywell/39348-ZW4005.png differ diff --git a/openzwave/images/honeywell/39348-ZW4008.png b/openzwave/images/honeywell/39348-ZW4008.png new file mode 100644 index 00000000..c6942e3b Binary files /dev/null and b/openzwave/images/honeywell/39348-ZW4008.png differ diff --git a/openzwave/images/honeywell/39349-ZW1002.png b/openzwave/images/honeywell/39349-ZW1002.png new file mode 100644 index 00000000..2b69238c Binary files /dev/null and b/openzwave/images/honeywell/39349-ZW1002.png differ diff --git a/openzwave/images/honeywell/39351-ZW3005.png b/openzwave/images/honeywell/39351-ZW3005.png new file mode 100644 index 00000000..d50afdbc Binary files /dev/null and b/openzwave/images/honeywell/39351-ZW3005.png differ diff --git a/openzwave/images/honeywell/39357-ZW3004.png b/openzwave/images/honeywell/39357-ZW3004.png new file mode 100644 index 00000000..1fab0bee Binary files /dev/null and b/openzwave/images/honeywell/39357-ZW3004.png differ diff --git a/openzwave/images/honeywell/39358-ZW4002.png b/openzwave/images/honeywell/39358-ZW4002.png new file mode 100644 index 00000000..cad58e06 Binary files /dev/null and b/openzwave/images/honeywell/39358-ZW4002.png differ diff --git a/openzwave/images/honeywell/39449-ZW4106.png b/openzwave/images/honeywell/39449-ZW4106.png new file mode 100644 index 00000000..ac29cab4 Binary files /dev/null and b/openzwave/images/honeywell/39449-ZW4106.png differ diff --git a/openzwave/images/honeywell/lynx-touch-l5100.png b/openzwave/images/honeywell/lynx-touch-l5100.png new file mode 100644 index 00000000..38340dca Binary files /dev/null and b/openzwave/images/honeywell/lynx-touch-l5100.png differ diff --git a/openzwave/images/honeywell/th6320zw2003.png b/openzwave/images/honeywell/th6320zw2003.png new file mode 100644 index 00000000..0719604d Binary files /dev/null and b/openzwave/images/honeywell/th6320zw2003.png differ diff --git a/openzwave/images/honeywell/th8320zw1000.png b/openzwave/images/honeywell/th8320zw1000.png new file mode 100644 index 00000000..7fff8d84 Binary files /dev/null and b/openzwave/images/honeywell/th8320zw1000.png differ diff --git a/openzwave/images/horstmann/asrzw.png b/openzwave/images/horstmann/asrzw.png new file mode 100644 index 00000000..2118bce5 Binary files /dev/null and b/openzwave/images/horstmann/asrzw.png differ diff --git a/openzwave/images/horstmann/hrt4zw.png b/openzwave/images/horstmann/hrt4zw.png new file mode 100644 index 00000000..2c889c53 Binary files /dev/null and b/openzwave/images/horstmann/hrt4zw.png differ diff --git a/openzwave/images/horstmann/scsc17.png b/openzwave/images/horstmann/scsc17.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/horstmann/scsc17.png differ diff --git a/openzwave/images/horstmann/ses301.png b/openzwave/images/horstmann/ses301.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/horstmann/ses301.png differ diff --git a/openzwave/images/horstmann/ses302.png b/openzwave/images/horstmann/ses302.png new file mode 100644 index 00000000..720991a7 Binary files /dev/null and b/openzwave/images/horstmann/ses302.png differ diff --git a/openzwave/images/horstmann/ses303.png b/openzwave/images/horstmann/ses303.png new file mode 100644 index 00000000..ea2b74f4 Binary files /dev/null and b/openzwave/images/horstmann/ses303.png differ diff --git a/openzwave/images/horstmann/sir321.png b/openzwave/images/horstmann/sir321.png new file mode 100644 index 00000000..ea07642a Binary files /dev/null and b/openzwave/images/horstmann/sir321.png differ diff --git a/openzwave/images/horstmann/srt321.png b/openzwave/images/horstmann/srt321.png new file mode 100644 index 00000000..068e9873 Binary files /dev/null and b/openzwave/images/horstmann/srt321.png differ diff --git a/openzwave/images/horstmann/srt323.png b/openzwave/images/horstmann/srt323.png new file mode 100644 index 00000000..264685e2 Binary files /dev/null and b/openzwave/images/horstmann/srt323.png differ diff --git a/openzwave/images/horstmann/ssr302.png b/openzwave/images/horstmann/ssr302.png new file mode 100644 index 00000000..2118bce5 Binary files /dev/null and b/openzwave/images/horstmann/ssr302.png differ diff --git a/openzwave/images/horstmann/ssr303.png b/openzwave/images/horstmann/ssr303.png new file mode 100644 index 00000000..8e8ad2fe Binary files /dev/null and b/openzwave/images/horstmann/ssr303.png differ diff --git a/openzwave/images/icare/zw-66.png b/openzwave/images/icare/zw-66.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/icare/zw-66.png differ diff --git a/openzwave/images/idlock/idlock101.png b/openzwave/images/idlock/idlock101.png new file mode 100644 index 00000000..6f6ad0ae Binary files /dev/null and b/openzwave/images/idlock/idlock101.png differ diff --git a/openzwave/images/idlock/idlock150.png b/openzwave/images/idlock/idlock150.png new file mode 100644 index 00000000..433e5709 Binary files /dev/null and b/openzwave/images/idlock/idlock150.png differ diff --git a/openzwave/images/ingersoll/dwzwave1.png b/openzwave/images/ingersoll/dwzwave1.png new file mode 100644 index 00000000..3bcd689b Binary files /dev/null and b/openzwave/images/ingersoll/dwzwave1.png differ diff --git a/openzwave/images/inovelli/lzw30-sn.png b/openzwave/images/inovelli/lzw30-sn.png new file mode 100644 index 00000000..d5c0d7f2 Binary files /dev/null and b/openzwave/images/inovelli/lzw30-sn.png differ diff --git a/openzwave/images/inovelli/lzw30.png b/openzwave/images/inovelli/lzw30.png new file mode 100644 index 00000000..14176ca0 Binary files /dev/null and b/openzwave/images/inovelli/lzw30.png differ diff --git a/openzwave/images/inovelli/lzw31-sn.png b/openzwave/images/inovelli/lzw31-sn.png new file mode 100644 index 00000000..7068c707 Binary files /dev/null and b/openzwave/images/inovelli/lzw31-sn.png differ diff --git a/openzwave/images/inovelli/lzw31.png b/openzwave/images/inovelli/lzw31.png new file mode 100644 index 00000000..b913210d Binary files /dev/null and b/openzwave/images/inovelli/lzw31.png differ diff --git a/openzwave/images/inovelli/lzw36.png b/openzwave/images/inovelli/lzw36.png new file mode 100644 index 00000000..b3be5c38 Binary files /dev/null and b/openzwave/images/inovelli/lzw36.png differ diff --git a/openzwave/images/inovelli/lzw40.png b/openzwave/images/inovelli/lzw40.png new file mode 100644 index 00000000..e559c88f Binary files /dev/null and b/openzwave/images/inovelli/lzw40.png differ diff --git a/openzwave/images/inovelli/lzw41.png b/openzwave/images/inovelli/lzw41.png new file mode 100644 index 00000000..e559c88f Binary files /dev/null and b/openzwave/images/inovelli/lzw41.png differ diff --git a/openzwave/images/inovelli/lzw42.png b/openzwave/images/inovelli/lzw42.png new file mode 100644 index 00000000..e559c88f Binary files /dev/null and b/openzwave/images/inovelli/lzw42.png differ diff --git a/openzwave/images/inovelli/lzw60.png b/openzwave/images/inovelli/lzw60.png new file mode 100644 index 00000000..8649b1a8 Binary files /dev/null and b/openzwave/images/inovelli/lzw60.png differ diff --git a/openzwave/images/inovelli/nzw30.png b/openzwave/images/inovelli/nzw30.png new file mode 100644 index 00000000..c8c9b5c9 Binary files /dev/null and b/openzwave/images/inovelli/nzw30.png differ diff --git a/openzwave/images/inovelli/simple_module.png b/openzwave/images/inovelli/simple_module.png new file mode 100644 index 00000000..42b55313 Binary files /dev/null and b/openzwave/images/inovelli/simple_module.png differ diff --git a/openzwave/images/iwatsu/ne-4ct-2p.png b/openzwave/images/iwatsu/ne-4ct-2p.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/iwatsu/ne-4ct-2p.png differ diff --git a/openzwave/images/iwatsu/ne-4ct.png b/openzwave/images/iwatsu/ne-4ct.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/iwatsu/ne-4ct.png differ diff --git a/openzwave/images/jasco/45601.png b/openzwave/images/jasco/45601.png new file mode 100644 index 00000000..4daa0f41 Binary files /dev/null and b/openzwave/images/jasco/45601.png differ diff --git a/openzwave/images/kaipule/im20.png b/openzwave/images/kaipule/im20.png new file mode 100644 index 00000000..d7c1487c Binary files /dev/null and b/openzwave/images/kaipule/im20.png differ diff --git a/openzwave/images/kwikset/888.png b/openzwave/images/kwikset/888.png new file mode 100644 index 00000000..fa999146 Binary files /dev/null and b/openzwave/images/kwikset/888.png differ diff --git a/openzwave/images/kwikset/914c.png b/openzwave/images/kwikset/914c.png new file mode 100644 index 00000000..e1852d7c Binary files /dev/null and b/openzwave/images/kwikset/914c.png differ diff --git a/openzwave/images/kwikset/916.jpg b/openzwave/images/kwikset/916.jpg new file mode 100644 index 00000000..185e958b Binary files /dev/null and b/openzwave/images/kwikset/916.jpg differ diff --git a/openzwave/images/kwikset/smartcode.png b/openzwave/images/kwikset/smartcode.png new file mode 100644 index 00000000..d12f6edd Binary files /dev/null and b/openzwave/images/kwikset/smartcode.png differ diff --git a/openzwave/images/leviton/dz15s.png b/openzwave/images/leviton/dz15s.png new file mode 100644 index 00000000..2e283cdf Binary files /dev/null and b/openzwave/images/leviton/dz15s.png differ diff --git a/openzwave/images/leviton/dz6hd.png b/openzwave/images/leviton/dz6hd.png new file mode 100644 index 00000000..3696b3fb Binary files /dev/null and b/openzwave/images/leviton/dz6hd.png differ diff --git a/openzwave/images/leviton/dzpa1.png b/openzwave/images/leviton/dzpa1.png new file mode 100644 index 00000000..c0b06054 Binary files /dev/null and b/openzwave/images/leviton/dzpa1.png differ diff --git a/openzwave/images/leviton/dzpd3.png b/openzwave/images/leviton/dzpd3.png new file mode 100644 index 00000000..02fb13f2 Binary files /dev/null and b/openzwave/images/leviton/dzpd3.png differ diff --git a/openzwave/images/leviton/vrcs2.png b/openzwave/images/leviton/vrcs2.png new file mode 100644 index 00000000..c8fb383c Binary files /dev/null and b/openzwave/images/leviton/vrcs2.png differ diff --git a/openzwave/images/leviton/vrf01.png b/openzwave/images/leviton/vrf01.png new file mode 100644 index 00000000..6efb5c2e Binary files /dev/null and b/openzwave/images/leviton/vrf01.png differ diff --git a/openzwave/images/leviton/vri10.png b/openzwave/images/leviton/vri10.png new file mode 100644 index 00000000..b65d24e2 Binary files /dev/null and b/openzwave/images/leviton/vri10.png differ diff --git a/openzwave/images/leviton/vrpa1.png b/openzwave/images/leviton/vrpa1.png new file mode 100644 index 00000000..c0b06054 Binary files /dev/null and b/openzwave/images/leviton/vrpa1.png differ diff --git a/openzwave/images/leviton/vrpd3.png b/openzwave/images/leviton/vrpd3.png new file mode 100644 index 00000000..7dc33d83 Binary files /dev/null and b/openzwave/images/leviton/vrpd3.png differ diff --git a/openzwave/images/leviton/vrs15.png b/openzwave/images/leviton/vrs15.png new file mode 100644 index 00000000..af52731f Binary files /dev/null and b/openzwave/images/leviton/vrs15.png differ diff --git a/openzwave/images/leviton/zw4sf.png b/openzwave/images/leviton/zw4sf.png new file mode 100644 index 00000000..ed5fd80a Binary files /dev/null and b/openzwave/images/leviton/zw4sf.png differ diff --git a/openzwave/images/linear/LB60Z-1.png b/openzwave/images/linear/LB60Z-1.png new file mode 100644 index 00000000..fa0c2e8f Binary files /dev/null and b/openzwave/images/linear/LB60Z-1.png differ diff --git a/openzwave/images/linear/WD500Z5-1.png b/openzwave/images/linear/WD500Z5-1.png new file mode 100644 index 00000000..16179a37 Binary files /dev/null and b/openzwave/images/linear/WD500Z5-1.png differ diff --git a/openzwave/images/linear/WT00Z5-1.png b/openzwave/images/linear/WT00Z5-1.png new file mode 100644 index 00000000..cb9a8661 Binary files /dev/null and b/openzwave/images/linear/WT00Z5-1.png differ diff --git a/openzwave/images/linear/gd00z-7.png b/openzwave/images/linear/gd00z-7.png new file mode 100644 index 00000000..6f4f9145 Binary files /dev/null and b/openzwave/images/linear/gd00z-7.png differ diff --git a/openzwave/images/linear/ngd00z.png b/openzwave/images/linear/ngd00z.png new file mode 100644 index 00000000..e7dac351 Binary files /dev/null and b/openzwave/images/linear/ngd00z.png differ diff --git a/openzwave/images/logicsoft/ZDB5100.png b/openzwave/images/logicsoft/ZDB5100.png new file mode 100644 index 00000000..3aa7876b Binary files /dev/null and b/openzwave/images/logicsoft/ZDB5100.png differ diff --git a/openzwave/images/logicsoft/ZHC5010.png b/openzwave/images/logicsoft/ZHC5010.png new file mode 100644 index 00000000..58519f89 Binary files /dev/null and b/openzwave/images/logicsoft/ZHC5010.png differ diff --git a/openzwave/images/mcohome/mh7h.png b/openzwave/images/mcohome/mh7h.png new file mode 100644 index 00000000..9215f85f Binary files /dev/null and b/openzwave/images/mcohome/mh7h.png differ diff --git a/openzwave/images/mcohome/mh8fceu0803.png b/openzwave/images/mcohome/mh8fceu0803.png new file mode 100644 index 00000000..28b7f375 Binary files /dev/null and b/openzwave/images/mcohome/mh8fceu0803.png differ diff --git a/openzwave/images/mcohome/mhp220.png b/openzwave/images/mcohome/mhp220.png new file mode 100644 index 00000000..8d8b4a3a Binary files /dev/null and b/openzwave/images/mcohome/mhp220.png differ diff --git a/openzwave/images/mcohome/mhp511.png b/openzwave/images/mcohome/mhp511.png new file mode 100644 index 00000000..73f39d0a Binary files /dev/null and b/openzwave/images/mcohome/mhp511.png differ diff --git a/openzwave/images/merten/5044xx.png b/openzwave/images/merten/5044xx.png new file mode 100644 index 00000000..7cffac43 Binary files /dev/null and b/openzwave/images/merten/5044xx.png differ diff --git a/openzwave/images/merten/5046xx.png b/openzwave/images/merten/5046xx.png new file mode 100644 index 00000000..7cffac43 Binary files /dev/null and b/openzwave/images/merten/5046xx.png differ diff --git a/openzwave/images/merten/506004.png b/openzwave/images/merten/506004.png new file mode 100644 index 00000000..f954e166 Binary files /dev/null and b/openzwave/images/merten/506004.png differ diff --git a/openzwave/images/merten/508244.png b/openzwave/images/merten/508244.png new file mode 100644 index 00000000..d74efbd1 Binary files /dev/null and b/openzwave/images/merten/508244.png differ diff --git a/openzwave/images/miyakawaelectric/me-d101.png b/openzwave/images/miyakawaelectric/me-d101.png new file mode 100644 index 00000000..07b757a9 Binary files /dev/null and b/openzwave/images/miyakawaelectric/me-d101.png differ diff --git a/openzwave/images/namron/1402756.png b/openzwave/images/namron/1402756.png new file mode 100644 index 00000000..2fe93953 Binary files /dev/null and b/openzwave/images/namron/1402756.png differ diff --git a/openzwave/images/nexia/db100z.png b/openzwave/images/nexia/db100z.png new file mode 100644 index 00000000..cd3e963f Binary files /dev/null and b/openzwave/images/nexia/db100z.png differ diff --git a/openzwave/images/nexia/th100nx.png b/openzwave/images/nexia/th100nx.png new file mode 100644 index 00000000..cd3e963f Binary files /dev/null and b/openzwave/images/nexia/th100nx.png differ diff --git a/openzwave/images/nodon/asp3100SmartPlug.png b/openzwave/images/nodon/asp3100SmartPlug.png new file mode 100644 index 00000000..fc5eb01b Binary files /dev/null and b/openzwave/images/nodon/asp3100SmartPlug.png differ diff --git a/openzwave/images/nodon/crc3100OctanRemote.png b/openzwave/images/nodon/crc3100OctanRemote.png new file mode 100644 index 00000000..ce81d276 Binary files /dev/null and b/openzwave/images/nodon/crc3100OctanRemote.png differ diff --git a/openzwave/images/nodon/crc360xSofremote.png b/openzwave/images/nodon/crc360xSofremote.png new file mode 100644 index 00000000..ed9fb866 Binary files /dev/null and b/openzwave/images/nodon/crc360xSofremote.png differ diff --git a/openzwave/images/nodon/cws3101wallswitch.png b/openzwave/images/nodon/cws3101wallswitch.png new file mode 100644 index 00000000..aa788052 Binary files /dev/null and b/openzwave/images/nodon/cws3101wallswitch.png differ diff --git a/openzwave/images/nodon/msp31xxMicroSmartPlug.png b/openzwave/images/nodon/msp31xxMicroSmartPlug.png new file mode 100644 index 00000000..62eb0036 Binary files /dev/null and b/openzwave/images/nodon/msp31xxMicroSmartPlug.png differ diff --git a/openzwave/images/northq/nq92021.png b/openzwave/images/northq/nq92021.png new file mode 100644 index 00000000..ab26f9ae Binary files /dev/null and b/openzwave/images/northq/nq92021.png differ diff --git a/openzwave/images/oomi/ft100.png b/openzwave/images/oomi/ft100.png new file mode 100644 index 00000000..329d37ee Binary files /dev/null and b/openzwave/images/oomi/ft100.png differ diff --git a/openzwave/images/oomi/ft111.png b/openzwave/images/oomi/ft111.png new file mode 100644 index 00000000..d285be89 Binary files /dev/null and b/openzwave/images/oomi/ft111.png differ diff --git a/openzwave/images/oomi/ft112.png b/openzwave/images/oomi/ft112.png new file mode 100644 index 00000000..4efcec75 Binary files /dev/null and b/openzwave/images/oomi/ft112.png differ diff --git a/openzwave/images/oomi/ft118.png b/openzwave/images/oomi/ft118.png new file mode 100644 index 00000000..8094d4f0 Binary files /dev/null and b/openzwave/images/oomi/ft118.png differ diff --git a/openzwave/images/permundo/psc132zw.png b/openzwave/images/permundo/psc132zw.png new file mode 100644 index 00000000..509cfc88 Binary files /dev/null and b/openzwave/images/permundo/psc132zw.png differ diff --git a/openzwave/images/permundo/psc234zw.png b/openzwave/images/permundo/psc234zw.png new file mode 100644 index 00000000..038dc996 Binary files /dev/null and b/openzwave/images/permundo/psc234zw.png differ diff --git a/openzwave/images/philio/pad02.png b/openzwave/images/philio/pad02.png new file mode 100644 index 00000000..e3060a89 Binary files /dev/null and b/openzwave/images/philio/pad02.png differ diff --git a/openzwave/images/philio/pan04.png b/openzwave/images/philio/pan04.png new file mode 100644 index 00000000..1a20fa4d Binary files /dev/null and b/openzwave/images/philio/pan04.png differ diff --git a/openzwave/images/philio/pan05.png b/openzwave/images/philio/pan05.png new file mode 100644 index 00000000..f0f0af84 Binary files /dev/null and b/openzwave/images/philio/pan05.png differ diff --git a/openzwave/images/philio/pan06.png b/openzwave/images/philio/pan06.png new file mode 100644 index 00000000..2a12fd41 Binary files /dev/null and b/openzwave/images/philio/pan06.png differ diff --git a/openzwave/images/philio/pan08.png b/openzwave/images/philio/pan08.png new file mode 100644 index 00000000..faf10fb3 Binary files /dev/null and b/openzwave/images/philio/pan08.png differ diff --git a/openzwave/images/philio/pan11-1.png b/openzwave/images/philio/pan11-1.png new file mode 100644 index 00000000..defa9770 Binary files /dev/null and b/openzwave/images/philio/pan11-1.png differ diff --git a/openzwave/images/philio/pan11.png b/openzwave/images/philio/pan11.png new file mode 100644 index 00000000..9093fdf9 Binary files /dev/null and b/openzwave/images/philio/pan11.png differ diff --git a/openzwave/images/philio/pan16.png b/openzwave/images/philio/pan16.png new file mode 100644 index 00000000..922b0f0c Binary files /dev/null and b/openzwave/images/philio/pan16.png differ diff --git a/openzwave/images/philio/phpab01.png b/openzwave/images/philio/phpab01.png new file mode 100644 index 00000000..8a8c7d96 Binary files /dev/null and b/openzwave/images/philio/phpab01.png differ diff --git a/openzwave/images/philio/phpat02.png b/openzwave/images/philio/phpat02.png new file mode 100644 index 00000000..5594563e Binary files /dev/null and b/openzwave/images/philio/phpat02.png differ diff --git a/openzwave/images/philio/phpsg01.png b/openzwave/images/philio/phpsg01.png new file mode 100644 index 00000000..1b0ebe15 Binary files /dev/null and b/openzwave/images/philio/phpsg01.png differ diff --git a/openzwave/images/philio/pse02.png b/openzwave/images/philio/pse02.png new file mode 100644 index 00000000..b2c5cddc Binary files /dev/null and b/openzwave/images/philio/pse02.png differ diff --git a/openzwave/images/philio/psm02.png b/openzwave/images/philio/psm02.png new file mode 100644 index 00000000..4e716d15 Binary files /dev/null and b/openzwave/images/philio/psm02.png differ diff --git a/openzwave/images/philio/psp05.png b/openzwave/images/philio/psp05.png new file mode 100644 index 00000000..c076fc43 Binary files /dev/null and b/openzwave/images/philio/psp05.png differ diff --git a/openzwave/images/philio/psr03-1b.png b/openzwave/images/philio/psr03-1b.png new file mode 100644 index 00000000..2ac223b7 Binary files /dev/null and b/openzwave/images/philio/psr03-1b.png differ diff --git a/openzwave/images/philio/psr04.png b/openzwave/images/philio/psr04.png new file mode 100644 index 00000000..9d60b6d7 Binary files /dev/null and b/openzwave/images/philio/psr04.png differ diff --git a/openzwave/images/philio/pst02-1c.png b/openzwave/images/philio/pst02-1c.png new file mode 100644 index 00000000..e0de889b Binary files /dev/null and b/openzwave/images/philio/pst02-1c.png differ diff --git a/openzwave/images/philio/pst02-b.png b/openzwave/images/philio/pst02-b.png new file mode 100644 index 00000000..e0de889b Binary files /dev/null and b/openzwave/images/philio/pst02-b.png differ diff --git a/openzwave/images/philio/pst02.png b/openzwave/images/philio/pst02.png new file mode 100644 index 00000000..c6dfcbde Binary files /dev/null and b/openzwave/images/philio/pst02.png differ diff --git a/openzwave/images/polycontrol/doorlock.png b/openzwave/images/polycontrol/doorlock.png new file mode 100644 index 00000000..2fbd775e Binary files /dev/null and b/openzwave/images/polycontrol/doorlock.png differ diff --git a/openzwave/images/polycontrol/doorlockv3.png b/openzwave/images/polycontrol/doorlockv3.png new file mode 100644 index 00000000..5d760f2e Binary files /dev/null and b/openzwave/images/polycontrol/doorlockv3.png differ diff --git a/openzwave/images/popp/004407.png b/openzwave/images/popp/004407.png new file mode 100644 index 00000000..79e4a8ad Binary files /dev/null and b/openzwave/images/popp/004407.png differ diff --git a/openzwave/images/popp/009303.png b/openzwave/images/popp/009303.png new file mode 100644 index 00000000..91eedc2a Binary files /dev/null and b/openzwave/images/popp/009303.png differ diff --git a/openzwave/images/popp/009402.png b/openzwave/images/popp/009402.png new file mode 100644 index 00000000..01236ec1 Binary files /dev/null and b/openzwave/images/popp/009402.png differ diff --git a/openzwave/images/popp/012501.png b/openzwave/images/popp/012501.png new file mode 100644 index 00000000..c9b41166 Binary files /dev/null and b/openzwave/images/popp/012501.png differ diff --git a/openzwave/images/popp/700045.png b/openzwave/images/popp/700045.png new file mode 100644 index 00000000..d72941f8 Binary files /dev/null and b/openzwave/images/popp/700045.png differ diff --git a/openzwave/images/popp/700168.png b/openzwave/images/popp/700168.png new file mode 100644 index 00000000..49da7e84 Binary files /dev/null and b/openzwave/images/popp/700168.png differ diff --git a/openzwave/images/popp/700397.png b/openzwave/images/popp/700397.png new file mode 100644 index 00000000..ef11c245 Binary files /dev/null and b/openzwave/images/popp/700397.png differ diff --git a/openzwave/images/popp/701202.png b/openzwave/images/popp/701202.png new file mode 100644 index 00000000..9ee1a363 Binary files /dev/null and b/openzwave/images/popp/701202.png differ diff --git a/openzwave/images/popp/dwt.png b/openzwave/images/popp/dwt.png new file mode 100644 index 00000000..893935c3 Binary files /dev/null and b/openzwave/images/popp/dwt.png differ diff --git a/openzwave/images/popp/smoke-detector.png b/openzwave/images/popp/smoke-detector.png new file mode 100644 index 00000000..7326ed8b Binary files /dev/null and b/openzwave/images/popp/smoke-detector.png differ diff --git a/openzwave/images/popp/solar-siren.png b/openzwave/images/popp/solar-siren.png new file mode 100644 index 00000000..87ea46dd Binary files /dev/null and b/openzwave/images/popp/solar-siren.png differ diff --git a/openzwave/images/popp/zweather.png b/openzwave/images/popp/zweather.png new file mode 100644 index 00000000..4e155740 Binary files /dev/null and b/openzwave/images/popp/zweather.png differ diff --git a/openzwave/images/prowell/zw-702.png b/openzwave/images/prowell/zw-702.png new file mode 100644 index 00000000..56b9591f Binary files /dev/null and b/openzwave/images/prowell/zw-702.png differ diff --git a/openzwave/images/q-light/q-light_puck.png b/openzwave/images/q-light/q-light_puck.png new file mode 100644 index 00000000..16182761 Binary files /dev/null and b/openzwave/images/q-light/q-light_puck.png differ diff --git a/openzwave/images/q-light/q-light_zerodim.png b/openzwave/images/q-light/q-light_zerodim.png new file mode 100644 index 00000000..f6b374c3 Binary files /dev/null and b/openzwave/images/q-light/q-light_zerodim.png differ diff --git a/openzwave/images/q-light/q-light_zerodim_2pol.png b/openzwave/images/q-light/q-light_zerodim_2pol.png new file mode 100644 index 00000000..f6b374c3 Binary files /dev/null and b/openzwave/images/q-light/q-light_zerodim_2pol.png differ diff --git a/openzwave/images/qees/reto-dimmer-plus.png b/openzwave/images/qees/reto-dimmer-plus.png new file mode 100644 index 00000000..817e7091 Binary files /dev/null and b/openzwave/images/qees/reto-dimmer-plus.png differ diff --git a/openzwave/images/qees/reto-plugin-switch.png b/openzwave/images/qees/reto-plugin-switch.png new file mode 100644 index 00000000..3ca29c82 Binary files /dev/null and b/openzwave/images/qees/reto-plugin-switch.png differ diff --git a/openzwave/images/qubino/ZMNHADx.png b/openzwave/images/qubino/ZMNHADx.png new file mode 100644 index 00000000..af7137e2 Binary files /dev/null and b/openzwave/images/qubino/ZMNHADx.png differ diff --git a/openzwave/images/qubino/ZMNHBDx.png b/openzwave/images/qubino/ZMNHBDx.png new file mode 100644 index 00000000..291566fa Binary files /dev/null and b/openzwave/images/qubino/ZMNHBDx.png differ diff --git a/openzwave/images/qubino/ZMNHCDx.png b/openzwave/images/qubino/ZMNHCDx.png new file mode 100644 index 00000000..df3a1b70 Binary files /dev/null and b/openzwave/images/qubino/ZMNHCDx.png differ diff --git a/openzwave/images/qubino/ZMNHDA2.png b/openzwave/images/qubino/ZMNHDA2.png new file mode 100644 index 00000000..fb7006db Binary files /dev/null and b/openzwave/images/qubino/ZMNHDA2.png differ diff --git a/openzwave/images/qubino/ZMNHDDx.png b/openzwave/images/qubino/ZMNHDDx.png new file mode 100644 index 00000000..e7f9564e Binary files /dev/null and b/openzwave/images/qubino/ZMNHDDx.png differ diff --git a/openzwave/images/qubino/ZMNHIDx.png b/openzwave/images/qubino/ZMNHIDx.png new file mode 100644 index 00000000..ae97439f Binary files /dev/null and b/openzwave/images/qubino/ZMNHIDx.png differ diff --git a/openzwave/images/qubino/ZMNHNDx.png b/openzwave/images/qubino/ZMNHNDx.png new file mode 100644 index 00000000..372a5c12 Binary files /dev/null and b/openzwave/images/qubino/ZMNHNDx.png differ diff --git a/openzwave/images/qubino/ZMNHODx.png b/openzwave/images/qubino/ZMNHODx.png new file mode 100644 index 00000000..372a5c12 Binary files /dev/null and b/openzwave/images/qubino/ZMNHODx.png differ diff --git a/openzwave/images/qubino/ZMNHQDx.png b/openzwave/images/qubino/ZMNHQDx.png new file mode 100644 index 00000000..aea7c6e6 Binary files /dev/null and b/openzwave/images/qubino/ZMNHQDx.png differ diff --git a/openzwave/images/qubino/ZMNHSDx.png b/openzwave/images/qubino/ZMNHSDx.png new file mode 100644 index 00000000..e0043c1d Binary files /dev/null and b/openzwave/images/qubino/ZMNHSDx.png differ diff --git a/openzwave/images/qubino/ZMNHTDx.png b/openzwave/images/qubino/ZMNHTDx.png new file mode 100644 index 00000000..308a4bb3 Binary files /dev/null and b/openzwave/images/qubino/ZMNHTDx.png differ diff --git a/openzwave/images/qubino/ZMNHVDx.png b/openzwave/images/qubino/ZMNHVDx.png new file mode 100644 index 00000000..ae97439f Binary files /dev/null and b/openzwave/images/qubino/ZMNHVDx.png differ diff --git a/openzwave/images/qubino/ZMNHWD1.png b/openzwave/images/qubino/ZMNHWD1.png new file mode 100644 index 00000000..9d3123a5 Binary files /dev/null and b/openzwave/images/qubino/ZMNHWD1.png differ diff --git a/openzwave/images/qubino/ZMNHYDx.png b/openzwave/images/qubino/ZMNHYDx.png new file mode 100644 index 00000000..1e5fb1a7 Binary files /dev/null and b/openzwave/images/qubino/ZMNHYDx.png differ diff --git a/openzwave/images/qubino/ZMNKADx.png b/openzwave/images/qubino/ZMNKADx.png new file mode 100644 index 00000000..aea7c6e6 Binary files /dev/null and b/openzwave/images/qubino/ZMNKADx.png differ diff --git a/openzwave/images/qubino/zmnhxdx.png b/openzwave/images/qubino/zmnhxdx.png new file mode 100644 index 00000000..e76f632e Binary files /dev/null and b/openzwave/images/qubino/zmnhxdx.png differ diff --git a/openzwave/images/quby/qb2.png b/openzwave/images/quby/qb2.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/quby/qb2.png differ diff --git a/openzwave/images/rcs/em52-zw.png b/openzwave/images/rcs/em52-zw.png new file mode 100644 index 00000000..1684eb52 Binary files /dev/null and b/openzwave/images/rcs/em52-zw.png differ diff --git a/openzwave/images/rcs/therm0009.png b/openzwave/images/rcs/therm0009.png new file mode 100644 index 00000000..cbab4151 Binary files /dev/null and b/openzwave/images/rcs/therm0009.png differ diff --git a/openzwave/images/remotec/bw8120eu.png b/openzwave/images/remotec/bw8120eu.png new file mode 100644 index 00000000..cdf747bd Binary files /dev/null and b/openzwave/images/remotec/bw8120eu.png differ diff --git a/openzwave/images/remotec/zfm-80.png b/openzwave/images/remotec/zfm-80.png new file mode 100644 index 00000000..13e16806 Binary files /dev/null and b/openzwave/images/remotec/zfm-80.png differ diff --git a/openzwave/images/remotec/zrc-100eu.png b/openzwave/images/remotec/zrc-100eu.png new file mode 100644 index 00000000..7ab7cd33 Binary files /dev/null and b/openzwave/images/remotec/zrc-100eu.png differ diff --git a/openzwave/images/remotec/zrc-90.png b/openzwave/images/remotec/zrc-90.png new file mode 100644 index 00000000..7df47350 Binary files /dev/null and b/openzwave/images/remotec/zrc-90.png differ diff --git a/openzwave/images/remotec/zts-110.png b/openzwave/images/remotec/zts-110.png new file mode 100644 index 00000000..83764dcb Binary files /dev/null and b/openzwave/images/remotec/zts-110.png differ diff --git a/openzwave/images/remotec/zts-500.png b/openzwave/images/remotec/zts-500.png new file mode 100644 index 00000000..d83320ea Binary files /dev/null and b/openzwave/images/remotec/zts-500.png differ diff --git a/openzwave/images/remotec/zurc.png b/openzwave/images/remotec/zurc.png new file mode 100644 index 00000000..560c81b9 Binary files /dev/null and b/openzwave/images/remotec/zurc.png differ diff --git a/openzwave/images/remotec/zxt-120.png b/openzwave/images/remotec/zxt-120.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/remotec/zxt-120.png differ diff --git a/openzwave/images/remotec/zxt-310.png b/openzwave/images/remotec/zxt-310.png new file mode 100644 index 00000000..8fb69123 Binary files /dev/null and b/openzwave/images/remotec/zxt-310.png differ diff --git a/openzwave/images/remotec/zxt-600.png b/openzwave/images/remotec/zxt-600.png new file mode 100644 index 00000000..18337365 Binary files /dev/null and b/openzwave/images/remotec/zxt-600.png differ diff --git a/openzwave/images/ring/PIR-SS.png b/openzwave/images/ring/PIR-SS.png new file mode 100644 index 00000000..8569959a Binary files /dev/null and b/openzwave/images/ring/PIR-SS.png differ diff --git a/openzwave/images/schlage/BE468ZP.png b/openzwave/images/schlage/BE468ZP.png new file mode 100644 index 00000000..49dfaf48 Binary files /dev/null and b/openzwave/images/schlage/BE468ZP.png differ diff --git a/openzwave/images/schlage/BE469.png b/openzwave/images/schlage/BE469.png new file mode 100644 index 00000000..65e23f31 Binary files /dev/null and b/openzwave/images/schlage/BE469.png differ diff --git a/openzwave/images/schlage/BE469ZP.png b/openzwave/images/schlage/BE469ZP.png new file mode 100644 index 00000000..602dd667 Binary files /dev/null and b/openzwave/images/schlage/BE469ZP.png differ diff --git a/openzwave/images/schlage/fe599.png b/openzwave/images/schlage/fe599.png new file mode 100644 index 00000000..bc7665dc Binary files /dev/null and b/openzwave/images/schlage/fe599.png differ diff --git a/openzwave/images/schlagelink/41.png b/openzwave/images/schlagelink/41.png new file mode 100644 index 00000000..f5a6d0af Binary files /dev/null and b/openzwave/images/schlagelink/41.png differ diff --git a/openzwave/images/sensative/strips.png b/openzwave/images/sensative/strips.png new file mode 100644 index 00000000..ced80fff Binary files /dev/null and b/openzwave/images/sensative/strips.png differ diff --git a/openzwave/images/sensative/stripscomfort.png b/openzwave/images/sensative/stripscomfort.png new file mode 100644 index 00000000..8ab430fb Binary files /dev/null and b/openzwave/images/sensative/stripscomfort.png differ diff --git a/openzwave/images/sercomm/sw-clp01-eu.png b/openzwave/images/sercomm/sw-clp01-eu.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/sercomm/sw-clp01-eu.png differ diff --git a/openzwave/images/shenzen_neo/ls03ch.jpg b/openzwave/images/shenzen_neo/ls03ch.jpg new file mode 100644 index 00000000..63a7786b Binary files /dev/null and b/openzwave/images/shenzen_neo/ls03ch.jpg differ diff --git a/openzwave/images/shenzen_neo/nas-ab01z.png b/openzwave/images/shenzen_neo/nas-ab01z.png new file mode 100644 index 00000000..c39f0a18 Binary files /dev/null and b/openzwave/images/shenzen_neo/nas-ab01z.png differ diff --git a/openzwave/images/shenzen_neo/nas-ds01z.png b/openzwave/images/shenzen_neo/nas-ds01z.png new file mode 100644 index 00000000..1a2b2d38 Binary files /dev/null and b/openzwave/images/shenzen_neo/nas-ds01z.png differ diff --git a/openzwave/images/shenzen_neo/nas-pd01z.png b/openzwave/images/shenzen_neo/nas-pd01z.png new file mode 100644 index 00000000..da6df42b Binary files /dev/null and b/openzwave/images/shenzen_neo/nas-pd01z.png differ diff --git a/openzwave/images/shenzen_neo/nas-pd02z.png b/openzwave/images/shenzen_neo/nas-pd02z.png new file mode 100644 index 00000000..2ff6debb Binary files /dev/null and b/openzwave/images/shenzen_neo/nas-pd02z.png differ diff --git a/openzwave/images/shenzen_neo/nas-wr01z.png b/openzwave/images/shenzen_neo/nas-wr01z.png new file mode 100644 index 00000000..531014e0 Binary files /dev/null and b/openzwave/images/shenzen_neo/nas-wr01z.png differ diff --git a/openzwave/images/shenzen_neo/nas-wr01ze.png b/openzwave/images/shenzen_neo/nas-wr01ze.png new file mode 100644 index 00000000..cf405354 Binary files /dev/null and b/openzwave/images/shenzen_neo/nas-wr01ze.png differ diff --git a/openzwave/images/shenzen_neo/nas-ws02z.png b/openzwave/images/shenzen_neo/nas-ws02z.png new file mode 100644 index 00000000..2196cf92 Binary files /dev/null and b/openzwave/images/shenzen_neo/nas-ws02z.png differ diff --git a/openzwave/images/shenzen_saykey/SK-3007-05.png b/openzwave/images/shenzen_saykey/SK-3007-05.png new file mode 100644 index 00000000..7a5676e1 Binary files /dev/null and b/openzwave/images/shenzen_saykey/SK-3007-05.png differ diff --git a/openzwave/images/simon/10002034-13X.png b/openzwave/images/simon/10002034-13X.png new file mode 100644 index 00000000..884c30c4 Binary files /dev/null and b/openzwave/images/simon/10002034-13X.png differ diff --git a/openzwave/images/simon/10002080-13X.png b/openzwave/images/simon/10002080-13X.png new file mode 100644 index 00000000..fbfec58e Binary files /dev/null and b/openzwave/images/simon/10002080-13X.png differ diff --git a/openzwave/images/smartthings/pgc401m.png b/openzwave/images/smartthings/pgc401m.png new file mode 100644 index 00000000..57faaff8 Binary files /dev/null and b/openzwave/images/smartthings/pgc401m.png differ diff --git a/openzwave/images/smartthings/sth-eth200.png b/openzwave/images/smartthings/sth-eth200.png new file mode 100644 index 00000000..acebef69 Binary files /dev/null and b/openzwave/images/smartthings/sth-eth200.png differ diff --git a/openzwave/images/steinel/is140-2.png b/openzwave/images/steinel/is140-2.png new file mode 100644 index 00000000..eb5f927d Binary files /dev/null and b/openzwave/images/steinel/is140-2.png differ diff --git a/openzwave/images/steinel/l810-led-ihf.png b/openzwave/images/steinel/l810-led-ihf.png new file mode 100644 index 00000000..e9dbda6b Binary files /dev/null and b/openzwave/images/steinel/l810-led-ihf.png differ diff --git a/openzwave/images/steinel/rs-led-d2.png b/openzwave/images/steinel/rs-led-d2.png new file mode 100644 index 00000000..7b683089 Binary files /dev/null and b/openzwave/images/steinel/rs-led-d2.png differ diff --git a/openzwave/images/steinel/xled-home-2.png b/openzwave/images/steinel/xled-home-2.png new file mode 100644 index 00000000..88cd1dbe Binary files /dev/null and b/openzwave/images/steinel/xled-home-2.png differ diff --git a/openzwave/images/stelpro/stzw402.png b/openzwave/images/stelpro/stzw402.png new file mode 100644 index 00000000..42fc8699 Binary files /dev/null and b/openzwave/images/stelpro/stzw402.png differ diff --git a/openzwave/images/sunricher/srzv9001k12dimz4.png b/openzwave/images/sunricher/srzv9001k12dimz4.png new file mode 100644 index 00000000..3ab90d22 Binary files /dev/null and b/openzwave/images/sunricher/srzv9001k12dimz4.png differ diff --git a/openzwave/images/sunricher/srzv9001k12dimz5.png b/openzwave/images/sunricher/srzv9001k12dimz5.png new file mode 100644 index 00000000..4d59a7a5 Binary files /dev/null and b/openzwave/images/sunricher/srzv9001k12dimz5.png differ diff --git a/openzwave/images/sunricher/srzv9001k8.png b/openzwave/images/sunricher/srzv9001k8.png new file mode 100644 index 00000000..5d3d881a Binary files /dev/null and b/openzwave/images/sunricher/srzv9001k8.png differ diff --git a/openzwave/images/sunricher/srzv9001t4dimeu.png b/openzwave/images/sunricher/srzv9001t4dimeu.png new file mode 100644 index 00000000..46bbf34e Binary files /dev/null and b/openzwave/images/sunricher/srzv9001t4dimeu.png differ diff --git a/openzwave/images/sunricher/srzv9001tccteu.png b/openzwave/images/sunricher/srzv9001tccteu.png new file mode 100644 index 00000000..65a8c411 Binary files /dev/null and b/openzwave/images/sunricher/srzv9001tccteu.png differ diff --git a/openzwave/images/sunricher/srzv9003t4rgbweu.png b/openzwave/images/sunricher/srzv9003t4rgbweu.png new file mode 100644 index 00000000..c7906808 Binary files /dev/null and b/openzwave/images/sunricher/srzv9003t4rgbweu.png differ diff --git a/openzwave/images/sunricher/srzv9101facct.png b/openzwave/images/sunricher/srzv9101facct.png new file mode 100644 index 00000000..64e19406 Binary files /dev/null and b/openzwave/images/sunricher/srzv9101facct.png differ diff --git a/openzwave/images/sunricher/srzv9101sachpeu.png b/openzwave/images/sunricher/srzv9101sachpeu.png new file mode 100644 index 00000000..186b3e3f Binary files /dev/null and b/openzwave/images/sunricher/srzv9101sachpeu.png differ diff --git a/openzwave/images/sunricher/zv2835rac.png b/openzwave/images/sunricher/zv2835rac.png new file mode 100644 index 00000000..1f071ad9 Binary files /dev/null and b/openzwave/images/sunricher/zv2835rac.png differ diff --git a/openzwave/images/sunricher/zv9101.png b/openzwave/images/sunricher/zv9101.png new file mode 100644 index 00000000..86ae7b2a Binary files /dev/null and b/openzwave/images/sunricher/zv9101.png differ diff --git a/openzwave/images/swiid/swiidinter.png b/openzwave/images/swiid/swiidinter.png new file mode 100644 index 00000000..b825522a Binary files /dev/null and b/openzwave/images/swiid/swiidinter.png differ diff --git a/openzwave/images/technisat/03009496.png b/openzwave/images/technisat/03009496.png new file mode 100644 index 00000000..767f6b62 Binary files /dev/null and b/openzwave/images/technisat/03009496.png differ diff --git a/openzwave/images/technisat/03009497.png b/openzwave/images/technisat/03009497.png new file mode 100644 index 00000000..190da74e Binary files /dev/null and b/openzwave/images/technisat/03009497.png differ diff --git a/openzwave/images/technisat/03009499.png b/openzwave/images/technisat/03009499.png new file mode 100644 index 00000000..860bd5ea Binary files /dev/null and b/openzwave/images/technisat/03009499.png differ diff --git a/openzwave/images/telldus/tzdw100.png b/openzwave/images/telldus/tzdw100.png new file mode 100644 index 00000000..db59e312 Binary files /dev/null and b/openzwave/images/telldus/tzdw100.png differ diff --git a/openzwave/images/telldus/tzwp100.png b/openzwave/images/telldus/tzwp100.png new file mode 100644 index 00000000..69a6666b Binary files /dev/null and b/openzwave/images/telldus/tzwp100.png differ diff --git a/openzwave/images/telldus/tzwp102.png b/openzwave/images/telldus/tzwp102.png new file mode 100644 index 00000000..3b1793ef Binary files /dev/null and b/openzwave/images/telldus/tzwp102.png differ diff --git a/openzwave/images/there/800z.png b/openzwave/images/there/800z.png new file mode 100644 index 00000000..6c4c2f0d Binary files /dev/null and b/openzwave/images/there/800z.png differ diff --git a/openzwave/images/thermofloor/Heatit-Z-Push-button-8-white.png b/openzwave/images/thermofloor/Heatit-Z-Push-button-8-white.png new file mode 100644 index 00000000..dd9c36d8 Binary files /dev/null and b/openzwave/images/thermofloor/Heatit-Z-Push-button-8-white.png differ diff --git a/openzwave/images/thermofloor/heatit021.png b/openzwave/images/thermofloor/heatit021.png new file mode 100644 index 00000000..bb16636e Binary files /dev/null and b/openzwave/images/thermofloor/heatit021.png differ diff --git a/openzwave/images/thermofloor/heatit056.png b/openzwave/images/thermofloor/heatit056.png new file mode 100644 index 00000000..20204ead Binary files /dev/null and b/openzwave/images/thermofloor/heatit056.png differ diff --git a/openzwave/images/thermofloor/heatit058.png b/openzwave/images/thermofloor/heatit058.png new file mode 100644 index 00000000..20204ead Binary files /dev/null and b/openzwave/images/thermofloor/heatit058.png differ diff --git a/openzwave/images/thermofloor/heatit20a.png b/openzwave/images/thermofloor/heatit20a.png new file mode 100644 index 00000000..34d1dac7 Binary files /dev/null and b/openzwave/images/thermofloor/heatit20a.png differ diff --git a/openzwave/images/thermofloor/heatit_zdim.png b/openzwave/images/thermofloor/heatit_zdim.png new file mode 100644 index 00000000..dd48a0de Binary files /dev/null and b/openzwave/images/thermofloor/heatit_zdim.png differ diff --git a/openzwave/images/trane/TZEMT400AB32MAA.png b/openzwave/images/trane/TZEMT400AB32MAA.png new file mode 100644 index 00000000..cb183854 Binary files /dev/null and b/openzwave/images/trane/TZEMT400AB32MAA.png differ diff --git a/openzwave/images/trane/TZEMT400BB32MAA.png b/openzwave/images/trane/TZEMT400BB32MAA.png new file mode 100644 index 00000000..27214d38 Binary files /dev/null and b/openzwave/images/trane/TZEMT400BB32MAA.png differ diff --git a/openzwave/images/trane/TZEMT524AA21MA.png b/openzwave/images/trane/TZEMT524AA21MA.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/trane/TZEMT524AA21MA.png differ diff --git a/openzwave/images/vera/vera2.png b/openzwave/images/vera/vera2.png new file mode 100644 index 00000000..1b4b1106 Binary files /dev/null and b/openzwave/images/vera/vera2.png differ diff --git a/openzwave/images/vision/1701.png b/openzwave/images/vision/1701.png new file mode 100644 index 00000000..7a59b65f Binary files /dev/null and b/openzwave/images/vision/1701.png differ diff --git a/openzwave/images/vision/brg1-433.png b/openzwave/images/vision/brg1-433.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/vision/brg1-433.png differ diff --git a/openzwave/images/vision/zd2102.png b/openzwave/images/vision/zd2102.png new file mode 100644 index 00000000..e08461f3 Binary files /dev/null and b/openzwave/images/vision/zd2102.png differ diff --git a/openzwave/images/vision/zd2105us5.png b/openzwave/images/vision/zd2105us5.png new file mode 100644 index 00000000..90458797 Binary files /dev/null and b/openzwave/images/vision/zd2105us5.png differ diff --git a/openzwave/images/vision/zd2201.png b/openzwave/images/vision/zd2201.png new file mode 100644 index 00000000..3c1c76c5 Binary files /dev/null and b/openzwave/images/vision/zd2201.png differ diff --git a/openzwave/images/vision/zd2301.png b/openzwave/images/vision/zd2301.png new file mode 100644 index 00000000..2289efe7 Binary files /dev/null and b/openzwave/images/vision/zd2301.png differ diff --git a/openzwave/images/vision/zl7101us.png b/openzwave/images/vision/zl7101us.png new file mode 100644 index 00000000..ffa1fb02 Binary files /dev/null and b/openzwave/images/vision/zl7101us.png differ diff --git a/openzwave/images/vision/zl7201us.png b/openzwave/images/vision/zl7201us.png new file mode 100644 index 00000000..ffa1fb02 Binary files /dev/null and b/openzwave/images/vision/zl7201us.png differ diff --git a/openzwave/images/vision/zl7431.png b/openzwave/images/vision/zl7431.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/vision/zl7431.png differ diff --git a/openzwave/images/vision/zl7432us.png b/openzwave/images/vision/zl7432us.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/vision/zl7432us.png differ diff --git a/openzwave/images/vision/zm1601eu.png b/openzwave/images/vision/zm1601eu.png new file mode 100644 index 00000000..cb76e105 Binary files /dev/null and b/openzwave/images/vision/zm1601eu.png differ diff --git a/openzwave/images/vision/zm1601eu5.png b/openzwave/images/vision/zm1601eu5.png new file mode 100644 index 00000000..1bf290aa Binary files /dev/null and b/openzwave/images/vision/zm1601eu5.png differ diff --git a/openzwave/images/vision/zm1602eu5.png b/openzwave/images/vision/zm1602eu5.png new file mode 100644 index 00000000..bea388d2 Binary files /dev/null and b/openzwave/images/vision/zm1602eu5.png differ diff --git a/openzwave/images/vision/zm1701.png b/openzwave/images/vision/zm1701.png new file mode 100644 index 00000000..081de743 Binary files /dev/null and b/openzwave/images/vision/zm1701.png differ diff --git a/openzwave/images/vision/zp3102.png b/openzwave/images/vision/zp3102.png new file mode 100644 index 00000000..c73f0418 Binary files /dev/null and b/openzwave/images/vision/zp3102.png differ diff --git a/openzwave/images/vision/zp3111.png b/openzwave/images/vision/zp3111.png new file mode 100644 index 00000000..1bbd3940 Binary files /dev/null and b/openzwave/images/vision/zp3111.png differ diff --git a/openzwave/images/vision/zr1202us.png b/openzwave/images/vision/zr1202us.png new file mode 100644 index 00000000..ba7e22be Binary files /dev/null and b/openzwave/images/vision/zr1202us.png differ diff --git a/openzwave/images/vision/zs610eu.png b/openzwave/images/vision/zs610eu.png new file mode 100644 index 00000000..59678a55 Binary files /dev/null and b/openzwave/images/vision/zs610eu.png differ diff --git a/openzwave/images/vision/zu1401jp.png b/openzwave/images/vision/zu1401jp.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/vision/zu1401jp.png differ diff --git a/openzwave/images/vitrum/vitrumI-Dimmer.png b/openzwave/images/vitrum/vitrumI-Dimmer.png new file mode 100644 index 00000000..e4229aec Binary files /dev/null and b/openzwave/images/vitrum/vitrumI-Dimmer.png differ diff --git a/openzwave/images/vitrum/vitrumI-Switch.png b/openzwave/images/vitrum/vitrumI-Switch.png new file mode 100644 index 00000000..e4229aec Binary files /dev/null and b/openzwave/images/vitrum/vitrumI-Switch.png differ diff --git a/openzwave/images/vitrum/vitrumII-Blind.png b/openzwave/images/vitrum/vitrumII-Blind.png new file mode 100644 index 00000000..a57b2cb5 Binary files /dev/null and b/openzwave/images/vitrum/vitrumII-Blind.png differ diff --git a/openzwave/images/vitrum/vitrumII-Dimmer.png b/openzwave/images/vitrum/vitrumII-Dimmer.png new file mode 100644 index 00000000..9aceeea2 Binary files /dev/null and b/openzwave/images/vitrum/vitrumII-Dimmer.png differ diff --git a/openzwave/images/vitrum/vitrumII-Switch.png b/openzwave/images/vitrum/vitrumII-Switch.png new file mode 100644 index 00000000..9aceeea2 Binary files /dev/null and b/openzwave/images/vitrum/vitrumII-Switch.png differ diff --git a/openzwave/images/wenzhou/tsp01.png b/openzwave/images/wenzhou/tsp01.png new file mode 100644 index 00000000..1009ff25 Binary files /dev/null and b/openzwave/images/wenzhou/tsp01.png differ diff --git a/openzwave/images/wenzhou/tz55.png b/openzwave/images/wenzhou/tz55.png new file mode 100644 index 00000000..ce42fef6 Binary files /dev/null and b/openzwave/images/wenzhou/tz55.png differ diff --git a/openzwave/images/wenzhou/tz56.png b/openzwave/images/wenzhou/tz56.png new file mode 100644 index 00000000..ce3ec199 Binary files /dev/null and b/openzwave/images/wenzhou/tz56.png differ diff --git a/openzwave/images/wenzhou/tz65d.png b/openzwave/images/wenzhou/tz65d.png new file mode 100644 index 00000000..59c6778b Binary files /dev/null and b/openzwave/images/wenzhou/tz65d.png differ diff --git a/openzwave/images/wenzhou/tz66d.png b/openzwave/images/wenzhou/tz66d.png new file mode 100644 index 00000000..7368bc8f Binary files /dev/null and b/openzwave/images/wenzhou/tz66d.png differ diff --git a/openzwave/images/wenzhou/tz67.png b/openzwave/images/wenzhou/tz67.png new file mode 100644 index 00000000..8270ba21 Binary files /dev/null and b/openzwave/images/wenzhou/tz67.png differ diff --git a/openzwave/images/wenzhou/tz68.png b/openzwave/images/wenzhou/tz68.png new file mode 100644 index 00000000..17cccd66 Binary files /dev/null and b/openzwave/images/wenzhou/tz68.png differ diff --git a/openzwave/images/wenzhou/tz69.png b/openzwave/images/wenzhou/tz69.png new file mode 100644 index 00000000..82cbca61 Binary files /dev/null and b/openzwave/images/wenzhou/tz69.png differ diff --git a/openzwave/images/wenzhou/tz78.png b/openzwave/images/wenzhou/tz78.png new file mode 100644 index 00000000..a294e310 Binary files /dev/null and b/openzwave/images/wenzhou/tz78.png differ diff --git a/openzwave/images/wenzhou/tz88.png b/openzwave/images/wenzhou/tz88.png new file mode 100644 index 00000000..9093fdf9 Binary files /dev/null and b/openzwave/images/wenzhou/tz88.png differ diff --git a/openzwave/images/widom/DRY.png b/openzwave/images/widom/DRY.png new file mode 100644 index 00000000..5696cbdd Binary files /dev/null and b/openzwave/images/widom/DRY.png differ diff --git a/openzwave/images/widom/UBS104.png b/openzwave/images/widom/UBS104.png new file mode 100644 index 00000000..0a9ec5eb Binary files /dev/null and b/openzwave/images/widom/UBS104.png differ diff --git a/openzwave/images/widom/UME304C_S.png b/openzwave/images/widom/UME304C_S.png new file mode 100644 index 00000000..35f6268a Binary files /dev/null and b/openzwave/images/widom/UME304C_S.png differ diff --git a/openzwave/images/widom/UMS2.png b/openzwave/images/widom/UMS2.png new file mode 100644 index 00000000..b2700bc8 Binary files /dev/null and b/openzwave/images/widom/UMS2.png differ diff --git a/openzwave/images/widom/WDS.png b/openzwave/images/widom/WDS.png new file mode 100644 index 00000000..fee8aa82 Binary files /dev/null and b/openzwave/images/widom/WDS.png differ diff --git a/openzwave/images/widom/WDS2.png b/openzwave/images/widom/WDS2.png new file mode 100644 index 00000000..5d18a396 Binary files /dev/null and b/openzwave/images/widom/WDS2.png differ diff --git a/openzwave/images/widom/WSP.png b/openzwave/images/widom/WSP.png new file mode 100644 index 00000000..08a22623 Binary files /dev/null and b/openzwave/images/widom/WSP.png differ diff --git a/openzwave/images/widom/WTED.png b/openzwave/images/widom/WTED.png new file mode 100644 index 00000000..a19a7c13 Binary files /dev/null and b/openzwave/images/widom/WTED.png differ diff --git a/openzwave/images/wink/wnk-mot1.png b/openzwave/images/wink/wnk-mot1.png new file mode 100644 index 00000000..54e4f547 Binary files /dev/null and b/openzwave/images/wink/wnk-mot1.png differ diff --git a/openzwave/images/wink/wnk-sir1p.png b/openzwave/images/wink/wnk-sir1p.png new file mode 100644 index 00000000..2736796a Binary files /dev/null and b/openzwave/images/wink/wnk-sir1p.png differ diff --git a/openzwave/images/zipato/HS1CA-Z.png b/openzwave/images/zipato/HS1CA-Z.png new file mode 100644 index 00000000..4cba740c Binary files /dev/null and b/openzwave/images/zipato/HS1CA-Z.png differ diff --git a/openzwave/images/zipato/HS1CG-Z.png b/openzwave/images/zipato/HS1CG-Z.png new file mode 100644 index 00000000..56a3f236 Binary files /dev/null and b/openzwave/images/zipato/HS1CG-Z.png differ diff --git a/openzwave/images/zipato/HS1SA-Z.png b/openzwave/images/zipato/HS1SA-Z.png new file mode 100644 index 00000000..41ee5391 Binary files /dev/null and b/openzwave/images/zipato/HS1SA-Z.png differ diff --git a/openzwave/images/zipato/HS1WL-Z.png b/openzwave/images/zipato/HS1WL-Z.png new file mode 100644 index 00000000..e1e62864 Binary files /dev/null and b/openzwave/images/zipato/HS1WL-Z.png differ diff --git a/openzwave/images/zipato/RGBBulb.png b/openzwave/images/zipato/RGBBulb.png new file mode 100644 index 00000000..8cf2d978 Binary files /dev/null and b/openzwave/images/zipato/RGBBulb.png differ diff --git a/openzwave/images/zipato/ne-nas-ab01z.png b/openzwave/images/zipato/ne-nas-ab01z.png new file mode 100644 index 00000000..9a0c36de Binary files /dev/null and b/openzwave/images/zipato/ne-nas-ab01z.png differ diff --git a/openzwave/images/zipato/pan04.png b/openzwave/images/zipato/pan04.png new file mode 100644 index 00000000..1a20fa4d Binary files /dev/null and b/openzwave/images/zipato/pan04.png differ diff --git a/openzwave/images/zipato/phpab01.png b/openzwave/images/zipato/phpab01.png new file mode 100644 index 00000000..8a8c7d96 Binary files /dev/null and b/openzwave/images/zipato/phpab01.png differ diff --git a/openzwave/images/zipato/pse02.png b/openzwave/images/zipato/pse02.png new file mode 100644 index 00000000..d235aa5b Binary files /dev/null and b/openzwave/images/zipato/pse02.png differ diff --git a/openzwave/images/zipato/pst02.png b/openzwave/images/zipato/pst02.png new file mode 100644 index 00000000..c6dfcbde Binary files /dev/null and b/openzwave/images/zipato/pst02.png differ diff --git a/openzwave/images/zipato/vszd2102.png b/openzwave/images/zipato/vszd2102.png new file mode 100644 index 00000000..e08461f3 Binary files /dev/null and b/openzwave/images/zipato/vszd2102.png differ diff --git a/openzwave/images/zipato/zd2301.png b/openzwave/images/zipato/zd2301.png new file mode 100644 index 00000000..1d4535ce Binary files /dev/null and b/openzwave/images/zipato/zd2301.png differ diff --git a/openzwave/images/zipato/zp3102.png b/openzwave/images/zipato/zp3102.png new file mode 100644 index 00000000..043844df Binary files /dev/null and b/openzwave/images/zipato/zp3102.png differ diff --git a/openzwave/images/zooz/zen06.png b/openzwave/images/zooz/zen06.png new file mode 100644 index 00000000..29f01b98 Binary files /dev/null and b/openzwave/images/zooz/zen06.png differ diff --git a/openzwave/images/zooz/zen15.png b/openzwave/images/zooz/zen15.png new file mode 100644 index 00000000..7106f359 Binary files /dev/null and b/openzwave/images/zooz/zen15.png differ diff --git a/openzwave/images/zooz/zen16.png b/openzwave/images/zooz/zen16.png new file mode 100644 index 00000000..5d69066a Binary files /dev/null and b/openzwave/images/zooz/zen16.png differ diff --git a/openzwave/images/zooz/zen20.png b/openzwave/images/zooz/zen20.png new file mode 100644 index 00000000..7c7a0197 Binary files /dev/null and b/openzwave/images/zooz/zen20.png differ diff --git a/openzwave/images/zooz/zen20v2.png b/openzwave/images/zooz/zen20v2.png new file mode 100644 index 00000000..1d11e585 Binary files /dev/null and b/openzwave/images/zooz/zen20v2.png differ diff --git a/openzwave/images/zooz/zen21.png b/openzwave/images/zooz/zen21.png new file mode 100644 index 00000000..04ef7d16 Binary files /dev/null and b/openzwave/images/zooz/zen21.png differ diff --git a/openzwave/images/zooz/zen21v3.png b/openzwave/images/zooz/zen21v3.png new file mode 100644 index 00000000..227316f1 Binary files /dev/null and b/openzwave/images/zooz/zen21v3.png differ diff --git a/openzwave/images/zooz/zen22.png b/openzwave/images/zooz/zen22.png new file mode 100644 index 00000000..588fe9c4 Binary files /dev/null and b/openzwave/images/zooz/zen22.png differ diff --git a/openzwave/images/zooz/zen23v3.png b/openzwave/images/zooz/zen23v3.png new file mode 100644 index 00000000..db4187cb Binary files /dev/null and b/openzwave/images/zooz/zen23v3.png differ diff --git a/openzwave/images/zooz/zen24v2.png b/openzwave/images/zooz/zen24v2.png new file mode 100644 index 00000000..6f3d69ab Binary files /dev/null and b/openzwave/images/zooz/zen24v2.png differ diff --git a/openzwave/images/zooz/zen26.png b/openzwave/images/zooz/zen26.png new file mode 100644 index 00000000..d27af0c7 Binary files /dev/null and b/openzwave/images/zooz/zen26.png differ diff --git a/openzwave/images/zooz/zen27.png b/openzwave/images/zooz/zen27.png new file mode 100644 index 00000000..60a428d0 Binary files /dev/null and b/openzwave/images/zooz/zen27.png differ diff --git a/openzwave/images/zooz/zen30.png b/openzwave/images/zooz/zen30.png new file mode 100644 index 00000000..e29fcd05 Binary files /dev/null and b/openzwave/images/zooz/zen30.png differ diff --git a/openzwave/images/zooz/zen31.png b/openzwave/images/zooz/zen31.png new file mode 100644 index 00000000..ab0b3910 Binary files /dev/null and b/openzwave/images/zooz/zen31.png differ diff --git a/openzwave/images/zooz/zse09.png b/openzwave/images/zooz/zse09.png new file mode 100644 index 00000000..09854c18 Binary files /dev/null and b/openzwave/images/zooz/zse09.png differ diff --git a/openzwave/images/zooz/zse19.png b/openzwave/images/zooz/zse19.png new file mode 100644 index 00000000..1100051b Binary files /dev/null and b/openzwave/images/zooz/zse19.png differ diff --git a/openzwave/images/zooz/zse29.png b/openzwave/images/zooz/zse29.png new file mode 100644 index 00000000..bf837e1d Binary files /dev/null and b/openzwave/images/zooz/zse29.png differ diff --git a/openzwave/images/zooz/zse30.png b/openzwave/images/zooz/zse30.png new file mode 100644 index 00000000..16f73da1 Binary files /dev/null and b/openzwave/images/zooz/zse30.png differ diff --git a/openzwave/images/zooz/zse33.png b/openzwave/images/zooz/zse33.png new file mode 100644 index 00000000..7d68afdc Binary files /dev/null and b/openzwave/images/zooz/zse33.png differ diff --git a/openzwave/images/zooz/zse40.png b/openzwave/images/zooz/zse40.png new file mode 100644 index 00000000..f7714460 Binary files /dev/null and b/openzwave/images/zooz/zse40.png differ diff --git a/openzwave/images/zwave.me/004001.png b/openzwave/images/zwave.me/004001.png new file mode 100644 index 00000000..7326ed8b Binary files /dev/null and b/openzwave/images/zwave.me/004001.png differ diff --git a/openzwave/images/zwave.me/ZME_05431.png b/openzwave/images/zwave.me/ZME_05431.png new file mode 100644 index 00000000..a496769c Binary files /dev/null and b/openzwave/images/zwave.me/ZME_05431.png differ diff --git a/openzwave/images/zwave.me/ZME_06433.png b/openzwave/images/zwave.me/ZME_06433.png new file mode 100644 index 00000000..a496769c Binary files /dev/null and b/openzwave/images/zwave.me/ZME_06433.png differ diff --git a/openzwave/images/zwave.me/ZME_06436.png b/openzwave/images/zwave.me/ZME_06436.png new file mode 100644 index 00000000..a496769c Binary files /dev/null and b/openzwave/images/zwave.me/ZME_06436.png differ diff --git a/openzwave/images/zwave.me/ZUno.png b/openzwave/images/zwave.me/ZUno.png new file mode 100644 index 00000000..0aefa780 Binary files /dev/null and b/openzwave/images/zwave.me/ZUno.png differ diff --git a/openzwave/images/zwave.me/kfob.png b/openzwave/images/zwave.me/kfob.png new file mode 100644 index 00000000..1f5e0e1f Binary files /dev/null and b/openzwave/images/zwave.me/kfob.png differ diff --git a/openzwave/images/zwave.me/popp_kfob-c.png b/openzwave/images/zwave.me/popp_kfob-c.png new file mode 100644 index 00000000..33278de4 Binary files /dev/null and b/openzwave/images/zwave.me/popp_kfob-c.png differ diff --git a/openzwave/images/zwave.me/razberry.png b/openzwave/images/zwave.me/razberry.png new file mode 100644 index 00000000..9ff878b6 Binary files /dev/null and b/openzwave/images/zwave.me/razberry.png differ diff --git a/openzwave/images/zwave.me/zme_raz5.png b/openzwave/images/zwave.me/zme_raz5.png new file mode 100644 index 00000000..81f759bf Binary files /dev/null and b/openzwave/images/zwave.me/zme_raz5.png differ diff --git a/openzwave/images/zwave.me/zweather.png b/openzwave/images/zwave.me/zweather.png new file mode 100644 index 00000000..4e155740 Binary files /dev/null and b/openzwave/images/zwave.me/zweather.png differ diff --git a/openzwave/images/zwp/PA-100.png b/openzwave/images/zwp/PA-100.png new file mode 100644 index 00000000..e0a36627 Binary files /dev/null and b/openzwave/images/zwp/PA-100.png differ diff --git a/openzwave/images/zwp/WD-100.png b/openzwave/images/zwp/WD-100.png new file mode 100644 index 00000000..1ef7a690 Binary files /dev/null and b/openzwave/images/zwp/WD-100.png differ diff --git a/openzwave/ingersoll/dwzwave1.xml b/openzwave/ingersoll/dwzwave1.xml new file mode 100644 index 00000000..ee15fb41 --- /dev/null +++ b/openzwave/ingersoll/dwzwave1.xml @@ -0,0 +1,34 @@ + + + http://www.openzwave.com/device-database/011F:0002:0001 + images/ingersoll/dwzwave1.png + https://products.z-wavealliance.org/products/647/ + Schlage_DWZWAVE1 + http://www.nexiahome.com/Products/ProductDetail.aspx?model=043156955534 + This sensor detects whether a door is open or closed and communicates with a Z-Wave gateway.Door window contacts should blend in with their environment and these contacts does just that by being one of the smallest in the industry. + +Each sensor comes in standard white with an optional and included brown cover. This allows you to quickly change the color to best match the decor. It's designed to work as well or better than the original manufacturer models, uses a long life lithium battery and is compatible with major alarm panel manufacturers. + Schlage Home Door and Window Sensor + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/647/xml + + + + + + + Enable or disable Basic Sets of 0x00 on a fault restore to nodes in Group 2. Default = Enabled. + + + + + + + + + + + + + diff --git a/openzwave/inovelli/lzw30-sn.xml b/openzwave/inovelli/lzw30-sn.xml new file mode 100644 index 00000000..0102acb6 --- /dev/null +++ b/openzwave/inovelli/lzw30-sn.xml @@ -0,0 +1,139 @@ + + + http://www.openzwave.com/device-database/031E:0001:0002 + images/inovelli/lzw30-sn.png + https://products.z-wavealliance.org/products/3451 + https://inovelli.com/shop/smart-light-switches/zwave-smart-switches-gen2/z-wave-on-off-switch-neutral-required-scenes-notifications/ + https://inovelli.com/shop/smart-light-switches/zwave-smart-switches-gen2/z-wave-on-off-switch-neutral-required-scenes-notifications/ + To Exclude your switch, put your HUB in exclusion mode and press the Configuration Button three (3) times. + U.S. / Canada / Mexico + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3451/LZW30-SN%20Manual.pdf + You may factory reset the switch by holding down the Config Button for twenty (20) or more seconds. The LED Bar will turn Red and blink three (3) times to confirm. + +However, we recommend using a certified Z-Wave controller to remove the device from your network for factory resetting the switch. + +Only use either of these procedures in the event that the network primary controller is missing or otherwise inoperable. + + The Inovelli Red Series On/Off is a Z-Wave in-wall switch that controls attached LED, CFL, & Incandescent lighting which can be highly customized to your liking at the switch itself with our unique config button and advanced firmware. In addition, the Red Series comes with advanced features such as scene support, power monitoring, notifications, local protection, etc. + LZW30-SN Switch + LZW30-SN + To include your switch, start the inclusion process on your HUB and tap the Configuration Button three (3) times. + +Please Note: If this doesn't work, you can check to see if your switch is within Z-Wave Range by holding down the Configuration Button for 5-10 seconds (if it's not within range, the LED Bar will indicate Red and if it is within Range, the LED Bar will indicate Green). If your switch indicates Red, please move the switch closer to the HUB. If your switch indicates Green, please try running an Exclusion to reset your switch. + + Adding Metadata + Remove Static Central Scene Entries - Issue #2155 + Add Instant On/Off Parameter + Clarifying which scenes are disabled with parameter 51 + Adding parameter 13 to manually specify the load if auto detection doesn't work + + + + + + + When Power is restored + Range: 0-2 + Default: 0 + + + + + + + + Inverts the orientation of the switch. Useful when the switch is installed upside down. Essentially up becomes down and down becomes up. + Range: 0-1 + Default: 0 + + + + + + + Automatically turns the switch off after this many seconds. When the switch is turned on a timer is started that is the duration of this setting. When the timer expires, the switch is turned off. + Range: 0-32767 + Default: 0 + + + + + When should the switch send commands to associated devices? 01 - local 02 - 3way 03 - 3way & local 04 - z-wave hub 05 - z-wave hub & local 06 - z-wave hub & 3-way 07 - z-wave hub & local & 3way 08 - timer 09 - timer & local 10 - timer & 3-way 11 - timer & 3-way & local 12 - timer & z-wave hub 13 - timer & z-wave hub & local 14 - timer & z-wave hub & 3-way 15 - all + Range: 0-15 + Default: 15 + + + + + This is the color of the LED strip. + Range: 0 to 255 + Default: 170 + + + + + This is the intensity of the LED strip. + Range: 0-10 + Default: 5 + + + + + This is the intensity of the LED strip when the switch is off. This is useful for users to see the light switch location when the lights are off. + Range: 0 - 10 + Default: 0 + + + + + Please see website for documentation. + Range: 0-83823359 + Default: 0 + + + + + The power level change that will result in a new power report being sent. The value is a percentage of the previous report. 0 = disabled. + Range: 0-100 + Default: 10 + + + + + Time period between consecutive power & energy reports being sent (in seconds). The timer is reset after each report is sent. + Range: 0 to 32767 + Default: 3600 + + + + + The energy level change that will result in a new energy report being sent. The value is a percentage of the previous report. + Range: 0-100 + Default: 10 + + + + + The default of the switch is to auto detect the load. In some situations you may want to try the option for a special load type. (firmware 1.17+) + + + + + + + Enables instant on (ie: disables the 700ms button delay). Note, if you disable the delay, it will also disable scene control except for the following: Up pressed, held, released, Down pressed, held, released & config button pressed. + + + + + + + + + + + + + + + diff --git a/openzwave/inovelli/lzw30.xml b/openzwave/inovelli/lzw30.xml new file mode 100644 index 00000000..79870df3 --- /dev/null +++ b/openzwave/inovelli/lzw30.xml @@ -0,0 +1,111 @@ + + + http://www.openzwave.com/device-database/031E:0001:0004 + images/inovelli/lzw30.png + https://products.z-wavealliance.org/products/3452 + https://inovelli.com/shop/smart-light-switches/zwave-smart-switches-gen2/pre-order-z-wave-on-off-switch-base-model/ + https://inovelli.com/shop/smart-light-switches/zwave-smart-switches-gen2/pre-order-z-wave-on-off-switch-base-model + To Exclude your switch, put your HUB in exclusion mode and press the Configuration Button three (3) times. + U.S. / Canada / Mexico + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3452/LZW30%20Manual.pdf + You may factory reset the switch by holding down the Config Button for twenty (20) or more seconds. The LED Bar will turn Red and blink three (3) times to confirm. + +However, we recommend using a certified Z-Wave controller to remove the device from your network for factory resetting the switch. + +Only use either of these procedures in the event that the network primary controller is missing or otherwise inoperable. + + The Inovelli On/Off switch is a Z-Wave device that controls attached LED, CFL, & Incandescent lighting which can be highly customized to your liking at the switch itself with our unique config button and advanced firmware. + LZW30 Switch + LZW30 + To include your switch, start the inclusion process on your HUB and tap the Configuration Button three (3) times. + +Please Note: If this doesn't work, you can check to see if your switch is within Z-Wave Range by holding down the Configuration Button for 5-10 seconds (if it's not within range, the LED Bar will indicate Red and if it is within Range, the LED Bar will indicate Green). If your switch indicates Red, please move the switch closer to the HUB. If your switch indicates Green, please try running an Exclusion to reset your switch. + + + Adding Metadata + Add Instant On/Off Parameter + Clarifying which scenes are disabled with parameter 51 + Adding parameter 13 to manually specify the load if auto detection doesn't work + + + + + + + When Power is restored + Range: 0-2 + Default: 0 + + + + + + + + Inverts the orientation of the switch. Useful when the switch is installed upside down. Essentially up becomes down and down becomes up. + Range: 0-1 + Default: 0 + + + + + + + Automatically turns the switch off after this many seconds. When the switch is turned on a timer is started that is the duration of this setting. When the timer expires, the switch is turned off. + Range: 0-32767 + Default: 0 + + + + + When should the switch send commands to associated devices? 01 - local 02 - 3way 03 - 3way & local 04 - z-wave hub 05 - z-wave hub & local 06 - z-wave hub & 3-way 07 - z-wave hub & local & 3way 08 - timer 09 - timer & local 10 - timer & 3-way 11 - timer & 3-way & local 12 - timer & z-wave hub 13 - timer & z-wave hub & local 14 - timer & z-wave hub & 3-way 15 - all + Range: 0-15 + Default: 15 + + + + + This is the color of the LED strip. + Range: 0 to 255 + Default: 170 + + + + + This is the intensity of the LED strip. + Range: 0-10 + Default: 5 + + + + + This is the intensity of the LED strip when the switch is off. This is useful for users to see the light switch location when the lights are off. + Range: 0 - 10 + Default: 0 + + + + + The default of the switch is to auto detect the load. In some situations you may want to try the option for a special load type. (firmware 1.17+) + + + + + + + Enables instant on (ie: disables the 700ms button delay). Note, if you disable the delay, it will also disable scene control except for the following: Up pres +sed, held, released, Down pressed, held, released & config button pressed. + + + + + + + + + + + + + + diff --git a/openzwave/inovelli/lzw31-sn.xml b/openzwave/inovelli/lzw31-sn.xml new file mode 100644 index 00000000..959d7f0c --- /dev/null +++ b/openzwave/inovelli/lzw31-sn.xml @@ -0,0 +1,255 @@ + + + http://www.openzwave.com/device-database/031E:0001:0001 + images/inovelli/lzw31-sn.png + https://products.z-wavealliance.org/products/3438 + https://inovelli.com/shop/smart-light-switches/zwave-smart-switches-gen2/pre-order-z-wave-dimmer-switch-no-neutral-required-scenes-notification/ + https://inovelli.com/shop/smart-light-switches/zwave-smart-switches-gen2/pre-order-z-wave-dimmer-switch-no-neutral-required-scenes-notification/ + To Exclude your switch, put your HUB in exclusion mode and press the Configuration Button three (3) times. + U.S. / Canada / Mexico + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3438/LZW31-SN%20Manual.pdf + You may factory reset the switch by holding down the Config Button for twenty (20) or more seconds. The LED Bar will turn Red and blink three (3) times to confirm. + +However, we recommend using a certified Z-Wave controller to remove the device from your network for factory resetting the switch. + +Only use either of these procedures in the event that the network primary controller is missing or otherwise inoperable. + + The Inovelli Red Series Dimmer is a Z-Wave in-wall dimmer that controls attached LED, CFL, & Incandescent lighting which can be highly customized to your liking at the switch itself with our unique config button and advanced firmware. The switch can also be used either with or without a neutral wire. In addition, the Red Series comes with advanced features such as scene support, power monitoring, notifications, local protection, etc. + LZW31-SN Dimmer + LZW31-SN + To include your switch, start the inclusion process on your HUB and tap the Configuration Button three (3) times. + +Please Note: If this doesn't work, you can check to see if your switch is within Z-Wave Range by holding down the Configuration Button for 5-10 seconds (if it's not within range, the LED Bar will indicate Red and if it is within Range, the LED Bar will indicate Green). If your switch indicates Red, please move the switch closer to the HUB. If your switch indicates Green, please try running an Exclusion to reset your switch. + + Initial Release + Update config for Firmware 1.47+ + Clarifying which scenes are disabled with parameter 51 + Fix maximum value for parameter 16 + Fixing value range for parameter 9 and 10 + + + + + + + This changes the speed in which the attached light dims up or down. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. + Range:0-100 + Default: 3 + + + + + This changes the speed in which the attached light dims up or down when controlled from the physical switch. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 101 should keep this in sync with parameter 1. + Range:0-101 + Default: 101 + + + + + This changes the speed in which the attached light turns on or off. For example, when a user sends the switch a basicSet(value: 0xFF) or basicSet(value: 0x00), this is the speed in which those actions take place. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 101 should keep this in sync with parameter 1. + Range:0-101 + Default: 101 + + + + + This changes the speed in which the attached light turns on or off from the physical switch. For example, when a user presses the up or down button, this is the speed in which those actions take place. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 101 should keep this in sync with parameter 1. + Range:0-101 + Default: 101 + + + + + The minimum level that the dimmer allows the bulb to be dimmed to. Useful when the user has an LED bulb that does not turn on or flickers at a lower level. + Range:1-45 + Default: 1 + + + + + The maximum level that the dimmer allows the bulb to be dimmed to. Useful when the user has an LED bulb that reaches its maximum level before the dimmer value of 99. + Range:55-99 + Default: 99 + + + + + Inverts the orientation of the switch. Useful when the switch is installed upside down. Essentially up becomes down and down becomes up. + Range: 0-1 + Default: 0 + + + + + + + Automatically turns the switch off after this many seconds. When the switch is turned on a timer is started that is the duration of this setting. When the timer expires, the switch is turned off. + Range:0-32767 + Default: 0 + + + + + Default level for the dimmer when it is powered on from the local switch. A setting of 0 means that the switch will return to the level that it was on before it was turned off. + Range:0-99 + Default: 0 + + + + + Default level for the dimmer when it is powered on from a Z-Wave command. A setting of 0 means that the switch will return to the level that it was on before it was turned off. + Range:0-99 + Default: 0 + + + + + The state the switch should return to once power is restored after power failure. 0 = off, 1-99 = level, 100=previous. + Range:0-100 + Default: 0 + + + + + When should the switch send commands to associated devices? 01 - local 02 - 3way 03 - 3way & local 04 - z-wave hub 05 - z-wave hub & local 06 - z-wave hub & 3-way 07 - z-wave hub & local & 3way 08 - timer 09 - timer & local 10 - timer & 3-way 11 - timer & 3-way & local 12 - timer & z-wave hub 13 - timer & z-wave hub & local 14 - timer & z-wave hub & 3-way 15 - all + Range: 0-15 + Default: 15 + + + + + This is the color of the LED strip. + Range: 0 to 255 + Default: 170 + + + + + This is the intensity of the LED strip. + Range: 0-10 + Default: 5 + + + + + + + + + + + + + + + + This is the intensity of the LED strip when the switch is off. This is useful for users to see the light switch location when the lights are off. + Range: 0-10 + Default: 1 + + + + + + + + + + + + + + + + Please see website for documentation. + Range: 0-100600575 + Default: 0 + + + + + When the LED strip is disabled (LED Strip Intensity is set to 0), this setting allows the LED strip to turn on temporarily while being adjusted. + Range: 0-10 + Default: 3 + + + + + + + + + + + + + + + + The power level change that will result in a new power report being sent. The value is a percentage of the previous report. 0 = disabled. + Range:0-100 + Default: 10 + + + + + Time period between consecutive power & energy reports being sent (in seconds). The timer is reset after each report is sent. + Range:0-32767 + Default: 3600 + + + + + The energy level change that will result in a new energy report being sent. The value is a percentage of the previous report. + Range:0-100 + Default: 10 + + + + + Configure the switch to use a neutral wire. + Range: 0-1 + Default: 1 + + + + + + + Configure the type of 3-way switch connected to the dimmer. + Range: 0-2 + Default: 0 + + + + + + + + Enables instant on (ie: disables the 700ms button delay). Note, if you disable the delay, it will also disable scene control except for the following: Up pres +sed, held, released, Down pressed, held, released & config button pressed. + + + + + + + + Optimize power output to be more compatible with smart bulbs. This prevents the dimmer from being able to dim and makes it act like an ON / OFF switch. (firmware 1.47+) + + + + + + + + + + + + + + + + + diff --git a/openzwave/inovelli/lzw31.xml b/openzwave/inovelli/lzw31.xml new file mode 100644 index 00000000..9051a1e2 --- /dev/null +++ b/openzwave/inovelli/lzw31.xml @@ -0,0 +1,225 @@ + + + http://www.openzwave.com/device-database/031E:0001:0003 + images/inovelli/lzw31.png + https://products.z-wavealliance.org/products/3442 + https://inovelli.com/shop/smart-light-switches/zwave-smart-switches-gen2/pre-order-z-wave-dimmer-switch-no-neutral-required/ + https://inovelli.com/shop/smart-light-switches/zwave-smart-switches-gen2/pre-order-z-wave-dimmer-switch-no-neutral-required/ + To Exclude your switch, put your HUB in exclusion mode and press the Configuration Button three (3) times. + U.S. / Canada / Mexico + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3442/LZW31%20Manual.pdf + You may factory reset the switch by holding down the Config Button for twenty (20) or more seconds. The LED Bar will turn Red and blink three (3) times to confirm. + +However, we recommend using a certified Z-Wave controller to remove the device from your network for factory resetting the switch. + +Only use either of these procedures in the event that the network primary controller is missing or otherwise inoperable. + + The Inovelli Dimmer has some amazing features such as a configuration button that allows you to change parameters without the need for a HUB. It also has an RGB LED bar that shows the dim level of the switch, the color and intensity can be changed and also has the ability to be off until the switch is manually dimmed. + LZW31 Dimmer + LZW31 + To include your switch, start the inclusion process on your HUB and tap the Configuration Button three (3) times. + +Please Note: If this doesn't work, you can check to see if your switch is within Z-Wave Range by holding down the Configuration Button for 5-10 seconds (if it's not within range, the LED Bar will indicate Red and if it is within Range, the LED Bar will indicate Green). If your switch indicates Red, please move the switch closer to the HUB. If your switch indicates Green, please try running an Exclusion to reset your switch. + + Initial Release + Update config for Firmware 1.47+ + Clarifying which scenes are disabled with parameter 51 + Fixing value range for parameter 9 and 10 + + + + + + + This changes the speed in which the attached light dims up or down. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. + Range:0-100 + Default: 3 + + + + + This changes the speed in which the attached light dims up or down when controlled from the physical switch. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 101 should keep this in sync with parameter 1. + Range:0-101 + Default: 101 + + + + + This changes the speed in which the attached light turns on or off. For example, when a user sends the switch a basicSet(value: 0xFF) or basicSet(value: 0x00), this is the speed in which those actions take place. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 101 should keep this in sync with parameter 1. + Range:0-101 + Default: 101 + + + + + This changes the speed in which the attached light turns on or off from the physical switch. For example, when a user presses the up or down button, this is the speed in which those actions take place. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 101 should keep this in sync with parameter 1. + Range:0-101 + Default: 101 + + + + + The minimum level that the dimmer allows the bulb to be dimmed to. Useful when the user has an LED bulb that does not turn on or flickers at a lower level. + Range:1-45 + Default: 1 + + + + + The maximum level that the dimmer allows the bulb to be dimmed to. Useful when the user has an LED bulb that reaches its maximum level before the dimmer value of 99. + Range:55-99 + Default: 99 + + + + + Inverts the orientation of the switch. Useful when the switch is installed upside down. Essentially up becomes down and down becomes up. + Range: 0-1 + Default: 0 + + + + + + + Automatically turns the switch off after this many seconds. When the switch is turned on a timer is started that is the duration of this setting. When the timer expires, the switch is turned off. + Range:0-32767 + Default: 0 + + + + + Default level for the dimmer when it is powered on from the local switch. A setting of 0 means that the switch will return to the level that it was on before it was turned off. + Range:0-99 + Default: 0 + + + + + Default level for the dimmer when it is powered on from a Z-Wave command. A setting of 0 means that the switch will return to the level that it was on before it was turned off. + Range:0-99 + Default: 0 + + + + + The state the switch should return to once power is restored after power failure. 0 = off, 1-99 = level, 100=previous. + Range:0-100 + Default: 0 + + + + + When should the switch send commands to associated devices? 01 - local 02 - 3way 03 - 3way & local 04 - z-wave hub 05 - z-wave hub & local 06 - z-wave hub & 3-way 07 - z-wave hub & local & 3way 08 - timer 09 - timer & local 10 - timer & 3-way 11 - timer & 3-way & local 12 - timer & z-wave hub 13 - timer & z-wave hub & local 14 - timer & z-wave hub & 3-way 15 - all + Range: 0-15 + Default: 15 + + + + + This is the color of the LED strip. + Range: 0 to 255 + Default: 170 + + + + + This is the intensity of the LED strip. + Range: 0-10 + Default: 5 + + + + + + + + + + + + + + + + This is the intensity of the LED strip when the switch is off. This is useful for users to see the light switch location when the lights are off. + Range: 0-10 + Default: 1 + + + + + + + + + + + + + + + + When the LED strip is disabled (LED Strip Intensity is set to 0), this setting allows the LED strip to turn on temporarily while being adjusted. + Range: 0-10 + Default: 3 + + + + + + + + + + + + + + + + Configure the switch to use a neutral wire. + Range: 0-1 + Default: 1 + + + + + + + Configure the type of 3-way switch connected to the dimmer. + Range: 0-2 + Default: 0 + + + + + + + + Enables instant on (ie: disables the 700ms button delay). Note, if you disable the delay, it will also disable scene control except for the following: Up pres +sed, held, released, Down pressed, held, released & config button pressed. + + + + + + + Optimize power output to be more compatible with smart bulbs. This prevents the dimmer from being able to dim and makes it act like an ON / OFF switch. (firmware 1.47+) + + + + + + + + + + + + + + + + + diff --git a/openzwave/inovelli/lzw36.xml b/openzwave/inovelli/lzw36.xml new file mode 100644 index 00000000..148321b4 --- /dev/null +++ b/openzwave/inovelli/lzw36.xml @@ -0,0 +1,334 @@ + + + http://www.openzwave.com/device-database/031E:0001:000e + images/inovelli/lzw36.png + https://inovelli.com/red-series-fan-light-switch-z-wave/ + https://support.inovelli.com/portal/en/kb/inovelli/products/switches-fan-light-red-series-lzw36 + https://products.z-wavealliance.org/products/3902 + To Exclude your switch, put your HUB in exclusion mode, hold the light up or down button and press the Light on/off button three (3) times. + U.S. / Canada / Mexico + https://support.inovelli.com/portal/api/kbArticles/407409000002102001/attachments/kw8eq50c812f5d3344bc08295860b8b394c7c/content?portalId=edbsn8bb12d5f5a97d693e61ce4ce8a23f8b0e323eac44a6c2794f893e912acf005df&inline=true + You may factory reset the switch by holding down the light up or down button and the light on/off button for twenty (20) or more seconds. The LED Bar will turn Red and blink three (3) times to confirm. + + The Inovelli Red Series Fan/Light Switch is a 700 Series Z-Wave in-wall fan + light switch that controls both your fan motor and its attached LED, CFL, & Incandescent bulbs which can be highly customized to your liking at the switch itself with our unique config buttons and advanced firmware. In addition, the Red Series comes with advanced features such as scene support, power monitoring, notifications, local protection, etc. This is the first of its kind that allows homes that only have one wire coming from the fan to the light switch and uses both a light switch and canopy module. Inspired and worked on by our wonderful community. + LZW36 Fan/Light Dimmer + LZW36 + put your HUB in exclusion mode, hold the light up or down button and press the Light on/off button three (3) times. + +Please Note: If this doesn't work, you can check to see if your switch is within Z-Wave Range by holding down the Light Button for 5-10 seconds (if it's not within range, the LED Bar will indicate Red and if it is within Range, the LED Bar will indicate Green). If your switch indicates Red, please move the switch closer to the HUB. If your switch indicates Green, please try running an Exclusion to reset your switch. + + + Adding Metadata + Fix Config Parameters + Adding additional metadata + Adding parameter 51 for firmware 1.36+ + + + + + + + + + This changes the speed in which the attached light dims up or down. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. + Range:0-98 + Default: 4 + + + + + + This changes the speed in which the attached light dims up or down when controlled from the physical switch. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 99 should keep this in sync with parameter 1. + Range:0-99 + Default: 99 + + + + + + This changes the speed in which the attached light turns on or off. For example, when a user sends the switch a basicSet(value: 0xFF) or basicSet(value: 0x00), this is the speed in which those actions take place. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 99 should keep this in sync with parameter 1. + Range:0-99 + Default: 99 + + + + + + This changes the speed in which the attached light turns on or off from the physical switch. For example, when a user presses the up or down button, this is the speed in which those actions take place. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 99 should keep this in sync with parameter 1. + Range:0-99 + Default: 99 + + + + + + The minimum level that the dimmer allows the bulb to be dimmed to. Useful when the user has an LED bulb that does not turn on or flickers at a lower level. + Range:1-45 + Default: 1 + + + + + + The maximum level that the dimmer allows the bulb to be dimmed to. Useful when the user has an LED bulb that reaches its maximum level before the dimmer value of 99. + Range:55-99 + Default: 99 + + + + + + The minimum level that the dimmer allows the fan to be dimmed to. Useful when the user has a fan that does not turn at a lower level. + Range:1-45 + Default: 1 + + + + + + The maximum level that the dimmer allows the fan to be dimmed to. + Range:55-99 + Default: 99 + + + + + + Automatically turns the light switch off after this many seconds. When the switch is turned on a timer is started that is the duration of this setting. When the timer expires, the switch is turned off. + Range:0-32767 + Default: 0 + + + + + + Automatically turns the fan switch off after this many seconds. When the switch is turned on a timer is started that is the duration of this setting. When the timer expires, the switch is turned off. + Range:0-32767 + Default: 0 + + + + + + Default level for the dimmer when it is powered on from the local switch. A setting of 0 means that the switch will return to the level that it was on before it was turned off. + Range:1-99 + Default: 0 + + + + + + Default level for the dimmer when it is powered on from a Z-Wave command. A setting of 0 means that the switch will return to the level that it was on before it was turned off. + Range:1-99 + Default: 0 + + + + + + Default level for the fan dimmer when it is powered on from the local switch. + Default: Last State + + + + + + + + + + Default level for the fan dimmer when it is powered on from the local switch. + Default: Last State + + + + + + + + + + The state the switch should return to once power is restored after power failure. 0 = off, 1-99 = level, 100=previous. + Range:0-100 + Default: 100 + + + + + + The state the switch should return to once power is restored after power failure. + Default: Off + + + + + + + + + + + This is the color of the Light LED strip represented as part of the HUE color wheel. Since the wheel has 360 values and this parameter only has 255, the following equation can be used to determine the color: value/255 * 360 = Hue color wheel value + Range: 0 to 255 + Default: 170 + + + + + + This is the intensity of the Light LED strip. + Range: 0-10 + Default: 5 + + + + + + This is the color of the Fan LED strip represented as part of the HUE color wheel. Since the wheel has 360 values and this parameter only has 255, the following equation can be used to determine the color: value/255 * 360 = Hue color wheel value + Range: 0 to 255 + Default: 170 + + + + + + This is the intensity of the Fan LED strip. + Range: 0-10 + Default: 5 + + + + + + This is the intensity of the Light LED strip when the switch is off. This is useful for users to see the light switch location when the lights are off. + Range: 0-10 + Default: 1 + + + + + + This is the intensity of the Fan LED strip when the switch is off. This is useful for users to see the light switch location when the lights are off. + Range: 0-10 + Default: 1 + + + + + + Please see website for documentation. + Byte 4: Effect - 0 = Off, 1 = Solid, 2 = Slow Blink, 3 = Fast Blink, 4 = Chase, 5 = Pulse + Byte 3: Duration - 1 to 60 = seconds, 61 to 120 minutes, 121 - 254 = hours, 255 = Indefinitely + Byte 2: Intensity - 0 to 9. 0 = dim, 9 = bright + Byte 1: Color - 0 - 255. Hue color wheel. value/255 * 360 = Hue color wheel value + Range: 0-100600319 + Default: 0 + + + + + + Please see website for documentation. + Byte 4: Effect - 0 = Off, 1 = Solid, 2 = Slow Blink, 3 = Fast Blink, 4 = Chase, 5 = Pulse + Byte 3: Duration - 1 to 60 = seconds, 61 to 120 minutes, 121 - 254 = hours, 255 = Indefinitely + Byte 2: Intensity - 0 to 9. 0 = dim, 9 = bright + Byte 1: Color - 0 - 255. Hue color wheel. value/255 * 360 = Hue color wheel value + Range: 0-100600319 + Default: 0 + + + + + + When the LED strip is disabled (Light LED Strip Intensity is set to 0), this setting allows the LED strip to turn on temporarily while being adjusted. + Range: 0-10 + Default: 3 + + + + + + + + + + + + + + + + + When the LED strip is disabled (Fan LED Strip Intensity is set to 0), this setting allows the LED strip to turn on temporarily while being adjusted. + Range: 0-10 + Default: 3 + + + + + + + + + + + + + + + + + The power level change that will result in a new power report being sent. The value is a percentage of the previous report. 0 = disabled. + Range:0-100 + Default: 10 + + + + + + Time period between consecutive power & energy reports being sent (in seconds). The timer is reset after each report is sent. + Range:0-32767 + Default: 3600 + + + + + + The energy level change that will result in a new energy report being sent. The value is a percentage of the previous report. + Range:0-100 + Default: 10 + + + + + + Enable local protection on these buttons. 0 = none, 1 = light, 2 = fan, 3 = both. + + + + + + + + + + Enables instant on (ie: disables the 700ms button delay). Note, if you disable the delay, it will also disable scene control except for the following: Light on/off pressed, held, released, Fan on/off pressed, held, released & light up/down fan up/down pressed (firmware 1.36+). + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/inovelli/lzw40.xml b/openzwave/inovelli/lzw40.xml new file mode 100644 index 00000000..a687f28b --- /dev/null +++ b/openzwave/inovelli/lzw40.xml @@ -0,0 +1,39 @@ + + + http://www.openzwave.com/device-database/031E:0001:0007 + images/inovelli/lzw40.png + https://products.z-wavealliance.org/products/3657 + https://inovelli.com/shop/z-wave-smart-bulbs/z-wave-smart-bulb/ + https://inovelli.com/shop/z-wave-smart-bulbs/z-wave-smart-bulb/ + Put your HUB in Exclusion mode and turn the power to the bulb on/off/on. + U.S. / Canada / Mexico + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3657/LZW40%20-%20Manual%20(Compressed).pdf + You may power on/off the bulb 6x (between 0.5-2 seconds each time) until the bulb factory resets. + With 806 lumens and smooth dimming, this bulb has it all. Best part? It's powered by Z-Wave Plus technology. Imagine walking into a room, tapping a switch (hopefully Inovelli) and your ilumin lights come on to a beautiful movie scene. Or as you're winding down for the night, the lights gradually dim off as you drift to sleep. These are some of the many things you can do with smart bulbs and we're excited to be able to share them with you. + LZW40 Dimmable Bulb + LZW40 + Put your HUB in Inclusion mode and turn the power to the bulb on/off/on. + + Initial commit + + + + + + + When Power is restored + Range: 0-2 + Default: 0 + + + + + + + + + + + + + diff --git a/openzwave/inovelli/lzw41.xml b/openzwave/inovelli/lzw41.xml new file mode 100644 index 00000000..f275b2d8 --- /dev/null +++ b/openzwave/inovelli/lzw41.xml @@ -0,0 +1,56 @@ + + + http://www.openzwave.com/device-database/031E:0001:0006 + images/inovelli/lzw41.png + https://products.z-wavealliance.org/products/3614 + https://inovelli.com/shop/z-wave-smart-bulbs/z-wave-cct-smart-bulb/ + https://inovelli.com/shop/z-wave-smart-bulbs/z-wave-cct-smart-bulb/ + Put your HUB in Exclusion mode and turn the power to the bulb on/off/on. + U.S. / Canada / Mexico + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3614/LZW41%20Manual.pdf + You may power on/off the bulb 6x (between 0.5-2 seconds each time) until the bulb factory resets. + With 806 lumens, tunable white, and smooth dimming, this bulb has it all. Best part? It's powered by Z-Wave Plus technology. Imagine walking into a room, tapping a switch (hopefully Inovelli) and your ilumin lights come on to a beautiful movie scene. Or as you're winding down for the night, switch from cool white to warm and gradually dim off the lights as you drift to sleep. These are some of the many things you can do with smart bulbs and we're excited to be able to share them with you. + LZW41 Tunable White Bulb + LZW41 + Put your HUB in Inclusion mode and turn the power to the bulb on/off/on. + + Initial commit + Fix config parameter numbers + + + + + + + When Power is restored + Range: 0-2 + Default: 0 + + + + + + + + Changes the Kelvin from 2700k (1387) to 4999k (4999) + Range: 1387-4999 + Default: 2700 + + + + + Changes the Kelvin from 5000k (5000) to 6500k (6500) + Range: 5000-6500 + Default: 6500 + + + + + + + + + + + + diff --git a/openzwave/inovelli/lzw42.xml b/openzwave/inovelli/lzw42.xml new file mode 100644 index 00000000..23d9d068 --- /dev/null +++ b/openzwave/inovelli/lzw42.xml @@ -0,0 +1,56 @@ + + + http://www.openzwave.com/device-database/031E:0001:0005 + images/inovelli/lzw42.png + https://products.z-wavealliance.org/products/3613 + https://inovelli.com/shop/z-wave-smart-bulbs/z-wave-rgbw-smart-bulb/ + https://inovelli.com/shop/z-wave-smart-bulbs/z-wave-rgbw-smart-bulb/ + Put your HUB in Exclusion mode and turn the power to the bulb on/off/on. + U.S. / Canada / Mexico + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3613/LZW42%20Manual.pdf + You may power on/off the bulb 6x (between 0.5-2 seconds each time) until the bulb factory resets. + With 806 lumens, millions of colors, tunable white, and smooth dimming, this bulb has it all. Best part? It's powered by Z-Wave Plus technology. Imagine walking into a room, tapping a switch (hopefully Inovelli) and your ilumin lights come on to a beautiful movie scene. Or as you're winding down for the night, switch from cool white to warm and gradually dim off the lights as you drift to sleep. These are some of the many things you can do with smart bulbs and we're excited to be able to share them with you. + LZW42 RGBW Bulb + LZW42 + Put your HUB in Inclusion mode and turn the power to the bulb on/off/on. + + Initial commit + Fix config parameter numbers + + + + + + + When Power is restored + Range: 0-2 + Default: 0 + + + + + + + + Changes the Kelvin from 2700k (1387) to 4999k (4999) + Range: 1387-4999 + Default: 2700 + + + + + Changes the Kelvin from 5000k (5000) to 6500k (6500) + Range: 5000-6500 + Default: 6500 + + + + + + + + + + + + diff --git a/openzwave/inovelli/lzw60.xml b/openzwave/inovelli/lzw60.xml new file mode 100644 index 00000000..d4dd2e37 --- /dev/null +++ b/openzwave/inovelli/lzw60.xml @@ -0,0 +1,131 @@ + + + http://www.openzwave.com/device-database/031E:000d:0001 + images/inovelli/lzw60.png + https://products.z-wavealliance.org/products/3723 + https://inovelli.com/shop/smart-sensors/z-wave-4-in-1-sensor/ + https://inovelli.com/shop/smart-sensors/z-wave-4-in-1-sensor/ + To Exclude your switch, put your HUB in exclusion mode and press the Sensor Button on the back of the device one (1) time. + U.S. / Canada / Mexico + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3723/Inovelli%204-1%20Sensor%20Manual.pdf + Control and Monitor Temperature, Light, Motion, and Humidity with the 4 in 1 Sensor. + LZW60 4-in-1 Sensor + LZW60 + To include your switch, start the inclusion process on your HUB and Sensor Button on the back of the device one (1) time. + + + Initial Release + + + + + + + Value at which the sensor reports low battery to the gateway + Range:10-50 + Default: 10 + + + + + Change the sensitivity of the PIR (Motion) Sensor + 0 = off, 1 = Low sensitivity, 10 = High sensitivity + Default: 8 + + + + + The amount of seconds between motion detection (ie: the interval) + Range:5-15300 + Default: 30 + + + + + Should Basic Set Command be sent after PIR is triggered? This is used to turn other devices on/off when motion is detected. + Default: No + + + + + + + Ability to reverse the Basic Set behavior for devices associated in group 2 + Default: ON when motion is tripped, OFF when motion stops + + + + + + + The interval in which the temperature sensor is checked, in seconds. Set to 0 to disable (Note: will be rounded to the nearest minute) + Default: 7200 (2 hours) + + + + + The interval in which the humidity sensor is checked, in seconds. Set to 0 to disable (Note: will be rounded to the nearest minute) + Default: 7200 (2 hours) + + + + + The interval in which the luminance sensor is checked, in seconds. Set to 0 to disable (Note: will be rounded to the nearest minute) + Default: 7200 (2 hours) + + + + + The interval in which the battery level is checked, in seconds. Set to 0 to disable (Note: will be rounded to the nearest minute) + Default: 86400 (24 hours) + + + + + Sensor reports are only checked at the interval defined in parameters 101-104. Should the sensor data always be reported, or only if the value has changed more than the threshold configured in parameters 111-114? + Always: Send sensor data every interval, even if the value did not change. + Threshold: Send sensor data on interval, but only if the value has changed by more than the defined threshold since the last report was sent. + Default: Always + + + + + + + Set the temperature threshold of the sensor. If Sensor Report Method = "Threshold", the temperature change must exceed this value in order to be reported to the hub. + Range: 1-500 + 1 = 0.1 degrees Celcius, 500 = 50 degrees Celcuis + Default: 10 (1 degree Celcuis) + + + + + Set the humidity threshold of the sensor. If Sensor Report Method = "Threshold", the humidity change must exceed this value in order to be reported to the hub. + Range: 1-32, 1 = 1%, 32 = 32% + Default: 5% + + + + + Set the luminance threshold of the sensor (in lux). If Sensor Report Method = "Threshold", the luminance change must exceed this value in order to be reported to the hub. + Range: 1-65528 + Default: 150 + + + + + Set the battery threshold of the sensor (percent). If Sensor Report Method = "Threshold", the battery level change must exceed this value in order to be reported to the hub. + Range: 1-100 + Default: 10 + + + + + + + + + + + + diff --git a/openzwave/inovelli/nzw1201.xml b/openzwave/inovelli/nzw1201.xml new file mode 100644 index 00000000..618c447d --- /dev/null +++ b/openzwave/inovelli/nzw1201.xml @@ -0,0 +1,15 @@ + + + + + + + + + + + + + + + diff --git a/openzwave/inovelli/nzw30.xml b/openzwave/inovelli/nzw30.xml new file mode 100644 index 00000000..2fe2fbff --- /dev/null +++ b/openzwave/inovelli/nzw30.xml @@ -0,0 +1,32 @@ + + + images/inovelli/nzw30.png + + Added pic + + + + + + Choose if you want the LED indicator to turn on when switch is on or off or disable completely. + + + + + + Controls the on/off orientation of the rocker switch + + + + + Automatically turn the switch off after this many seconds. 0 is disabled + + + + + + + + + + diff --git a/openzwave/inovelli/nzw31.xml b/openzwave/inovelli/nzw31.xml new file mode 100644 index 00000000..d889fcec --- /dev/null +++ b/openzwave/inovelli/nzw31.xml @@ -0,0 +1,65 @@ + + + + + + Each step of the dimming process will increase or decrease the brightness by this percentage. Increasing this will make the transition time slower. 0 is instant. + + + This is the minimum value to which the switch will dim. Useful for CFL or LED lights that otherwise won't come on or come on but flicker/buzz. + + + Choose if you want the LED indicator to turn on when switch is on or off or disable completely. + + + + + + + Controls the on/off orientation of the rocker switch + + + + + Automatically turn the switch off after this many seconds. 0 is disabled, or up to 32767 seconds + + + Change how devices respond when associated in group 3 + + + + + Send association group 3 commands on these types of actions + + + + + + + + + + + + + + + + + + + Default brightness when switch is turned on locally. 0 is previous. Firmware 1.02+" + + + Default brightness when switch is turned on via zwave. 0 is previous. Firmware 1.02+" + + + + + + + + + + + diff --git a/openzwave/inovelli/nzw36.xml b/openzwave/inovelli/nzw36.xml new file mode 100644 index 00000000..30b175ad --- /dev/null +++ b/openzwave/inovelli/nzw36.xml @@ -0,0 +1,23 @@ + + + + + + Choose if you want the LED indicator to turn on when switch is on or off or disable completely. + + + + + + Automatically turn the switch off after this many seconds. 0 is disabled + + + + + + + + + + + diff --git a/openzwave/inovelli/nzw37.xml b/openzwave/inovelli/nzw37.xml new file mode 100644 index 00000000..c9e9c73a --- /dev/null +++ b/openzwave/inovelli/nzw37.xml @@ -0,0 +1,26 @@ + + + + + + Choose if you want the LED indicator to turn on when switch is on or off or disable completely. + + + + + + Automatically turn channel 1 off after this many seconds. 0 is disabled + + + Automatically turn channel 2 off after this many seconds. 0 is disabled + + + + + + + + + + + diff --git a/openzwave/inovelli/nzw39.xml b/openzwave/inovelli/nzw39.xml new file mode 100644 index 00000000..30b175ad --- /dev/null +++ b/openzwave/inovelli/nzw39.xml @@ -0,0 +1,23 @@ + + + + + + Choose if you want the LED indicator to turn on when switch is on or off or disable completely. + + + + + + Automatically turn the switch off after this many seconds. 0 is disabled + + + + + + + + + + + diff --git a/openzwave/inovelli/nzw96.xml b/openzwave/inovelli/nzw96.xml new file mode 100644 index 00000000..45192e25 --- /dev/null +++ b/openzwave/inovelli/nzw96.xml @@ -0,0 +1,24 @@ + + + + + + Choose if you want the LED indicator to turn on when switch is on or off or disable completely. + + + + + + Automatically turn the switch off after this many seconds. 0 is disabled + + + + + + + + + + + + diff --git a/openzwave/inovelli/nzw97.xml b/openzwave/inovelli/nzw97.xml new file mode 100644 index 00000000..a5405a15 --- /dev/null +++ b/openzwave/inovelli/nzw97.xml @@ -0,0 +1,27 @@ + + + + + + Choose if you want the LED indicator to turn on when switch is on or off or disable completely. + + + + + + Automatically turn channel 1 off after this many seconds. 0 is disabled + + + Automatically turn channel 2 off after this many seconds. 0 is disabled + + + + + + + + + + + + diff --git a/openzwave/inovelli/simple_module.xml b/openzwave/inovelli/simple_module.xml new file mode 100644 index 00000000..09b8cf31 --- /dev/null +++ b/openzwave/inovelli/simple_module.xml @@ -0,0 +1,41 @@ + + + http://www.openzwave.com/device-database/0312:241C:B211 + images/inovelli/simple_module.png + https://products.z-wavealliance.org/products/2461/ + Press and hold the top button for at least 3 seconds while you plug the smart switch into a receptacle. +Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + ZW37 + Smart Plug Switch (2 channel) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2461/ZW37-Manual70615.pdf + The 2 ports smart plug provides one Z-Wave outlet for remote controlled by controller through Z-Wave gateway for internet of thing service and can be configured in Z-Wave sensor network, + 1. Follow the instructions for your Z-Wave certified controller to include + a device to the Z-Wave network. +2. Once the controller is ready to include your device, press up and + release the toggle to include it in the network. + U.S. / Canada / Mexico + 1. Follow the instructions for your Z-Wave certified controller to exclude + a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press up and + release the toggle to exclude it from the network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2352/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2357/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2358/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2379/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2385/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2461/xml + + https://products.z-wavealliance.org/products/2379/ + NZW39 + U.S. / Canada / Mexico + + + + + + + + + + diff --git a/openzwave/intermatic/ca8900.xml b/openzwave/intermatic/ca8900.xml new file mode 100644 index 00000000..695dd4f6 --- /dev/null +++ b/openzwave/intermatic/ca8900.xml @@ -0,0 +1,8 @@ + + + + + 0 + + + diff --git a/openzwave/iris/rangeextender.xml b/openzwave/iris/rangeextender.xml new file mode 100644 index 00000000..7226e366 --- /dev/null +++ b/openzwave/iris/rangeextender.xml @@ -0,0 +1,5 @@ + + + + + diff --git a/openzwave/iwatsu/ne-4ct-2p.xml b/openzwave/iwatsu/ne-4ct-2p.xml new file mode 100644 index 00000000..fdf5295b --- /dev/null +++ b/openzwave/iwatsu/ne-4ct-2p.xml @@ -0,0 +1,16 @@ + + + http://www.openzwave.com/device-database/0123:0102:0102 + images/iwatsu/ne-4ct-2p.png + https://products.z-wavealliance.org/products/946/ + NE-4CT-2P + Japan + Iwatsu Smart Connect NE-4CT-2P + Smart-CONNECT CT. + +Electric power measuring equipment with Z-Wave. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/946/xml + + + diff --git a/openzwave/iwatsu/ne-4ct.xml b/openzwave/iwatsu/ne-4ct.xml new file mode 100644 index 00000000..7d5854e8 --- /dev/null +++ b/openzwave/iwatsu/ne-4ct.xml @@ -0,0 +1,16 @@ + + + http://www.openzwave.com/device-database/0123:0103:0103 + images/iwatsu/ne-4ct.png + https://products.z-wavealliance.org/products/947/ + Smart-CONNECT CT. + +Electric power measuring instrument with Z-Wave + Iwatsu Smart Connect NE-4CT + NE-4CT + Japan + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/947/xml + + + diff --git a/openzwave/jasco/45601.xml b/openzwave/jasco/45601.xml new file mode 100644 index 00000000..dded23dd --- /dev/null +++ b/openzwave/jasco/45601.xml @@ -0,0 +1,26 @@ + + + http://www.openzwave.com/device-database/0020:1391:8007 + images/jasco/45601.png + https://products.z-wavealliance.org/products/289/ + U.S. / Canada / Mexico + http://www.jascoproducts.com/support + Jasco LCD Z-Wave Remote. The GE Advanced Remote turns on/off and adjusts the brightness level of Z-Wave enabled lights, as well as operates the on/off functions of Z-Wave enabled small appliances. Users create and manage custom lighting schemes by controlling up to 18 individual lights, 18 groups, and 18 scenes. The LCD menu screen allows for quick navigation of remote features and easy-to-read command feedback, while the timer function allows for up to nine timed events to be automatically activated in the home. The remote also works with Z-Wave enabled thermostats. To find out more how GE Z-Wave can help you save energy, take control and feel safe. +Features: +Control your entire home from one remote +Turn on/off and adjust the brightness of Z-Wave enabled lights +Operates the on/off functions of Z-Wave enabled small appliances +Manage up to 18 individual lights, 18 groups, and 18 scenes +Create custom lighting groups and scenes +On-screen LCD menu provides easy navigation of features and command feedback +Program up to nine timed events with advanced timer +Label function allows you to name lights, groups, and scenes + Lighting Control Advanced Remote, Thermostat Control, 18 Lights/Groups/Scenes + 45601 + www.ezzwave.com + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/289/xml + + + + diff --git a/openzwave/kaipule/im20.xml b/openzwave/kaipule/im20.xml new file mode 100644 index 00000000..78a9bd18 --- /dev/null +++ b/openzwave/kaipule/im20.xml @@ -0,0 +1,50 @@ + + + http://www.openzwave.com/device-database/0214:0001:0002 + images/kaipule/im20.png + https://products.z-wavealliance.org/products/2027/ + enter the Exclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the door sensor will be removed after a period of time. + U.S. / Canada / Mexico + IM20_Zwave is a door/window sensor adopting Zwave500 series chip. It uses special structure design, suitable for kinds of installation environments. Also, it supports door & window open/close detection, anti-tamper, battery level detection and associated gateway and interaction device notifications. + Z-Wave DOOR SENSOR + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2027/IM20-Z-Wave Product Manual.pdf + IM20-Z-Wave + Press the tamper switch 6 times in 2s, it will recover to factory setting after a period of time(Please use the reset procedure only when the primary controller is missing or inoperable) + a) Manual Wake-up +Quickly press tamper switch once, the door sensor will automatically send wake-up information, and there will be 10s after wake-up to receive gateway setting information. +b) Automatic Wake-up +Default time of automatic wake-up is 24 hours, and there will be 10s after wake-up to receive gateway setting information, the max automatic report time = 24 hours, minimum=30min + enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s,then the door sensor will stay in enrollment state until successfully enrolled into network or enrollment time out after 30s. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2027/xml + + + + + + + Basic Set parameter setting, the receivers make relevant adjustment according to parameter value + + + + If there is any device under Association Group2, the door sensor will send Basic Set = value command to Group2, and send Basic Set = 0x00 command to turn-off light after t seconds, Set value = t, means to send Basic Set command after t seconds. + + + + + Under normal working status (without trigger), the door sensor will automatically send report to the Gateway about its current tamper and open/close status. + Set value = t, means t hours, (t=0, means no status report). + 0-24 hours (Default 6 hours) + + + + + + + + + + diff --git a/openzwave/kaipule/ix32.xml b/openzwave/kaipule/ix32.xml new file mode 100644 index 00000000..fe79a1bb --- /dev/null +++ b/openzwave/kaipule/ix32.xml @@ -0,0 +1,24 @@ + + + + + + + Basic Set parameter setting, the receivers make relevant adjustment according to parameter value + + + When the device triggered and sends out BASIC SET to the lightings, the light turns on and off as the set time. + The minimum value is 1, means the light bright time is 1*5s (5 seconds), and turn off after 5 seconds, if the value is t, means the bright time is t*5s, turn off after t*5 seconds. + + + Eliminate alarm after 5xt seconds. + + + + + + + + + + diff --git a/openzwave/kwikset/888.xml b/openzwave/kwikset/888.xml new file mode 100644 index 00000000..12b27b8a --- /dev/null +++ b/openzwave/kwikset/888.xml @@ -0,0 +1,124 @@ + + + http://www.openzwave.com/device-database/0090:0541:0003 + images/kwikset/888.png + https://products.z-wavealliance.org/products/2176 + U.S. / Canada / Mexico + 888 + https://www.kwikset.com/products/detail/888-smartcode-electronic-deadbolt-with-z-wave-technology + Extend your smart home system to your current deadbolt, enabling your existing deadbolt to wirelessly communicate with your smart home or security system +Dramatically reduced, all-metal interior +Works with existing select single cylinder deadbolts + http://www.kwikset.com/Customer-Support/Overview.aspx + SmartCode 888 + + Initial Version + Add Config Params + + The electronic conversion kit remains asleep until an action occurs on the latch or a request is received from the RF side. +For the RF side, it will wake up every 1 second to check if there are any requests from your smart home controller. + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2268/Install_Guide_914C_03_09_2017.pdf + Initiate the process to add the lock to your system at your smart home controller. +When prompted by your smart home system to add the lock, press button “A” on the lock interior one time. The red LED will illuminate when the lock enters Add Mode. +Please allow time for the controller to add the lock to your system. + Follow your smart home system’s instructions to remove the lock from the network. When prompted by the system, press button A” on the lock interior once. The red LED will illuminate when the lock enters Remove mode. + A factory reset will delete all user codes associated with the lock and will remove itself from your smart home system. +Please only perform a factory reset when the primary controller is missing or inoperable. + +To perform a factory reset, please perform the following: +1. Remove the battery pack +2. Press and HOLD the Program button while reinserting the battery pack. +3. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red. +4. Press the Program button once more. The status LED will flash green and red several times. +5. After a few seconds, the lock will initiate the door handing process. + + + + + The configuration parameters 33 and 34 are used to set and get the SKU part numbers. +The SKU is made up of 8 bytes. Each parameter consists of four bytes of data. +Parameter 33 contains the first four most significant bytes of the SKU, while parameter +34 contains the four least significant bytes of the SKU. +When setting the SKU, it must be done in two set commands, one for each parameter. +The order of programming the SKU does not matter. +Setting parameter 33 will program the first four bytes of the SKU. Setting parameter 34 +will program the last 4 bytes of the SKU. Most printable values are accepted for the set +command. +When getting the SKU, it must be done in two get commands, one for each parameter. +The order of getting the SKU does not matter. +Getting parameter 33 will retrieve the first four bytes of the SKU. Getting parameter 34 +will retrieve the last 4 bytes of the SKU. + + + + The Configuration Parameter 33 and 34 are used to set the SKU part numbers to the Kwikset locks. + Is the least four significant bytes (LSB). + + + + The configuration parameter 35 is a one byte field that will allow the user to get / set the +value for the Interior Status LED control. The value of 0 means that the setting is +disabled; whereas the value of 1 means that the setting is enabled. +Sending a set command with the default field set to 1 will cause the control to revert back +to its factory default setting. + + + The configuration parameter 36 uses 2 bytes that will allow the user to get / set the value +for the Auto Lock feature and timing for that feature. The first byte will be the +enable/disable byte. The value of 0 means that the setting is disabled; whereas the value +of 1 means that the setting is enabled. The next two bytes will be the timing for the Auto +Lock feature and should contain the number of seconds before the Auto Lock will occur. +The valid values are: 0 (default – 30 seconds), 30, 60, 90, 120, 180. For example, setting +the auto lock feature for 60 seconds, the two timing bytes should be: 0x003C. +Sending a set command with the default field set to 1 will cause the control to revert back +to its factory default settings. + + + + + + + + + The configuration parameter 37 is a one byte field that will allow the user to get / set the +value for the Audio feature. The value of 0 means that the setting is disabled; whereas +the value of 1 means that the setting is enabled. +Sending a set command with the default field set to 1 will cause the control to revert back +to its factory default setting. + + + + Reset to factory defaults + + + + + + The configuration parameter 47 uses 1 byte that will allow the user to get / set the value +to enable or disable the motor load alarm. Setting this byte to 0 will disable the alarm, +whereas setting this byte to 1 will enable the alarm. If a motor load alarm has been +activated and the alarm has been enabled, the alarm will be sent via the Power +Management group in the Notification Command Class as a Load Error (0x09). + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/kwikset/910.xml b/openzwave/kwikset/910.xml new file mode 100644 index 00000000..dd606d08 --- /dev/null +++ b/openzwave/kwikset/910.xml @@ -0,0 +1,369 @@ + + + http://www.openzwave.com/device-database/0090:0001:0001 + images/kwikset/smartcode.png + https://products.z-wavealliance.org/products/945/ + U.S. / Canada / Mexico + 910 + http://www.kwikset.com/Products/Details/Electronic-Locks/910TRL-ZW-15-SMT.aspx + Weiser introduces the SmartCode™ 10 Touchpad Electronic Deadbolt with Z-Wave. + +10 digit backlit keypad with one touch locking +Dramatically reduced, all-metal interior +30 user codes plus master code +BHMA grade 2 certified +20 minute fire rating - UL certified +Full 128-bit encryption security +SmartKey: Re-key the lock in seconds + http://www.kwikset.com/Customer-Support/Overview.aspx + SmartCode 10 Touchpad Electronic Deadbolt + + Fixed TriggerRefresh Index to properly update lock status via Alarm Type. + + Even though the lock is sleeping, all buttons are active and can be used to initiate any lock activity. +For the RF side, it will wake up every 1 second to check if there are any requests from your smart home controller. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2369/Install Guide GED1800 04112017.pdf + Initiate the process to add the lock to your system at your smart home controller. +When prompted by your smart home system to add the lock, press button “A” on the lock interior one time. The red LED will illuminate when the lock enters Add Mode. +Please allow time for the controller to add the lock to your system. + Follow your smart home system’s instructions to remove the lock from the network. When prompted by the system, press button A” on the lock interior once. The red LED will illuminate when the lock enters Remove mode. + A factory reset will delete all user codes associated with the lock and will remove itself from your smart home system. +Please only perform a factory reset when the primary controller is missing or inoperable. + +To perform a factory reset, please perform the following: +1. Remove the battery pack +2. Press and HOLD the Program button while reinserting the battery pack. +3. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red. +4. Press the Program button once more. The status LED will flash green and red several times. +5. After a few seconds, the lock will initiate the door handing process. + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + Bit mask field that returns the state of the user accessible Dipswitches on the door look. + Bit 0 Lock LED Status (1: enable) + Bit 1 Auto lock (1: enable) + Bit 2 Auto Buzzer (1: enable) + Bit 3 Secure Screen (1: enable) *Only for MB 916 + + + + The Configuration Parameter 33 and 34 are used to set the SKU part numbers to the Kwikset locks. + Is the first four most significant bytes (MSB). + Below describes how Configuration Parameter 33 and 34 are being used. + * For a ZW Configuration Set, the DLM will first do a GET_SKU_ID to retrieve the full SKU from the lock, and the lock will respond with all 8 bytes. (If it not yet set, the DLM will consider that as all 0x30s.) + The DLM changes only the appropriate 4 bytes in its local copy of the SKU, and it then sends the full 8 bytes down to the lock in a SET_SKU_ID. + * For a ZW Configuration Get, the DLM will do a GET_SKU_ID down to the lock, to which the lock will respond with all 8 bytes. + The DLM will return the requested 4 bytes via ZW. If the SKU is not set, it will return all 0x30s (ASCII 0s). + + + + The Configuration Parameter 33 and 34 are used to set the SKU part numbers to the Kwikset locks. + Is the least four significant bytes (LSB). + + + + Unique ID of the lock type + 910 Z-Wave (Legacy, FW 3.4) 0x00 0x00 + 912 Z-Wave (Legacy, FW 3.2) 0x00 0x00 + 910 Z-Wave 0x02 0x36 + 912 Z-Wave 0x03 0x36 + 914 Z-Wave 0x04 0x36 + 916 Z-Wave 0x06 0x42 + + + + Reset to factory defaults + + + + + + + + + + + + + + + + + diff --git a/openzwave/kwikset/914c.xml b/openzwave/kwikset/914c.xml new file mode 100644 index 00000000..5ea6fd56 --- /dev/null +++ b/openzwave/kwikset/914c.xml @@ -0,0 +1,81 @@ + + + http://www.openzwave.com/device-database/0090:0446:0003 + images/kwikset/914c.png + https://products.z-wavealliance.org/products/2268 + U.S. / Canada / Mexico + 914C + https://www.kwikset.com/products/detail/kwikset-convert-smart-lock-conversion-kit-with-z-wave-technology + Extend your smart home system to your current deadbolt, enabling your existing deadbolt to wirelessly communicate with your smart home or security system +Dramatically reduced, all-metal interior +Works with existing select single cylinder deadbolts + http://www.kwikset.com/Customer-Support/Overview.aspx + Convert Electronic Deadbolt + + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2268/xml + Fixed index of alarm message to trigger lock status refresh + + The electronic conversion kit remains asleep until an action occurs on the latch or a request is received from the RF side. +For the RF side, it will wake up every 1 second to check if there are any requests from your smart home controller. + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2268/Install_Guide_914C_03_09_2017.pdf + Initiate the process to add the lock to your system at your smart home controller. +When prompted by your smart home system to add the lock, press button “A” on the lock interior one time. The red LED will illuminate when the lock enters Add Mode. +Please allow time for the controller to add the lock to your system. + Follow your smart home system’s instructions to remove the lock from the network. When prompted by the system, press button A” on the lock interior once. The red LED will illuminate when the lock enters Remove mode. + A factory reset will delete all user codes associated with the lock and will remove itself from your smart home system. +Please only perform a factory reset when the primary controller is missing or inoperable. + +To perform a factory reset, please perform the following: +1. Remove the battery pack +2. Press and HOLD the Program button while reinserting the battery pack. +3. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red. +4. Press the Program button once more. The status LED will flash green and red several times. +5. After a few seconds, the lock will initiate the door handing process. + + + + + Bit mask field that returns the state of the user accessible Dipswitches on the door look. + Bit 0 Lock LED Status (1: enable) + Bit 1 Autolock (1: enable) + Bit 2 Buzzer (1: enable) + Bit 3 Handing Invert (1: enable) + + + + The Configuration Parameter 33 and 34 are used to set the SKU part numbers to the Kwikset locks. + Is the first four most significant bytes (MSB). + Below describes how Configuration Parameter 33 and 34 are being used. + * For a ZW Configuration Set, the DLM will first do a GET_SKU_ID to retrieve the full SKU from the lock, and the lock will respond with all 8 bytes. (If it not yet set, the DLM will consider that as all 0x30s.) + The DLM changes only the appropriate 4 bytes in its local copy of the SKU, and it then sends the full 8 bytes down to the lock in a SET_SKU_ID. + * For a ZW Configuration Get, the DLM will do a GET_SKU_ID down to the lock, to which the lock will respond with all 8 bytes. + The DLM will return the requested 4 bytes via ZW. If the SKU is not set, it will return all 0x30s (ASCII 0s). + + + + The Configuration Parameter 33 and 34 are used to set the SKU part numbers to the Kwikset locks. + Is the least four significant bytes (LSB). + + + + Reset to factory defaults + + + + + + + + + + + + + + + + + diff --git a/openzwave/kwikset/916.xml b/openzwave/kwikset/916.xml new file mode 100644 index 00000000..33dbbec8 --- /dev/null +++ b/openzwave/kwikset/916.xml @@ -0,0 +1,372 @@ + + + http://www.openzwave.com/device-database/0090:0001:0001 + images/kwikset/916.jpg + https://products.z-wavealliance.org/products/2188/ + U.S. / Canada / Mexico + 916 + https://www.kwikset.com/support/productdetail/916-smartcode-traditional-electronic-deadbolt-with-z-wave-technology + Kwikset®, the leader in residential security, introduces the SmartCode™ 916 Touchscreen Electronic Deadbolt with Z-Wave. + +Capacitive touchscreen +SecureScreen: Additional security by preventing fingerprint code detection +One touch locking +Dramatically reduced, all-metal interior +30 user codes plus master code +BHMA grade 2 certified +20 minute fire rating - UL certified +Full 128-bit encryption security +SmartKey: Re-key the lock in seconds + http://www.kwikset.com/Customer-Support/Overview.aspx + SmartCode 916 Touchscreen Electronic Deadbolt + + Initial Version + + + Even though the lock is sleeping, all buttons are active and can be used to initiate any lock activity. +For the RF side, it will wake up every 1 second to check if there are any requests from your smart home controller. + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2188/Install_Guide_916_01_23_2017.pdf + Initiate the process to add the lock to your system at your smart home controller. +When prompted by your smart home system to add the lock, press button “A” on the lock interior one time. The red LED will illuminate when the lock enters Add Mode. +Please allow time for the controller to add the lock to your system. + Follow your smart home system’s instructions to remove the lock from the network. When prompted by the system, press button A” on the lock interior once. The red LED will illuminate when the lock enters Remove mode. + A factory reset will delete all user codes associated with the lock and will remove itself from your smart home system. +Please only perform a factory reset when the primary controller is missing or inoperable. + +To perform a factory reset, please perform the following: +1. Remove the battery pack +2. Press and HOLD the Program button while reinserting the battery pack. +3. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red. +4. Press the Program button once more. The status LED will flash green and red several times. +5. After a few seconds, the lock will initiate the door handing process. + https://products.z-wavealliance.org/products/2188/ + U.S. / Canada / Mexico + 916 + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + Bit mask field that returns the state of the user accessible Dipswitches on the door look. + Bit 0 Lock LED Status (1: enable) + Bit 1 Auto lock (1: enable) + Bit 2 Auto Buzzer (1: enable) + Bit 3 Secure Screen (1: enable) *Only for MB 916 + + + + The Configuration Parameter 33 and 34 are used to set the SKU part numbers to the Kwikset locks. + Is the first four most significant bytes (MSB). + Below describes how Configuration Parameter 33 and 34 are being used. + * For a ZW Configuration Set, the DLM will first do a GET_SKU_ID to retrieve the full SKU from the lock, and the lock will respond with all 8 bytes. (If it not yet set, the DLM will consider that as all 0x30s.) + The DLM changes only the appropriate 4 bytes in its local copy of the SKU, and it then sends the full 8 bytes down to the lock in a SET_SKU_ID. + * For a ZW Configuration Get, the DLM will do a GET_SKU_ID down to the lock, to which the lock will respond with all 8 bytes. + The DLM will return the requested 4 bytes via ZW. If the SKU is not set, it will return all 0x30s (ASCII 0s). + + + + The Configuration Parameter 33 and 34 are used to set the SKU part numbers to the Kwikset locks. + Is the least four significant bytes (LSB). + + + + Unique ID of the lock type + 910 Z-Wave (Legacy, FW 3.4) 0x00 0x00 + 912 Z-Wave (Legacy, FW 3.2) 0x00 0x00 + 910 Z-Wave 0x02 0x36 + 912 Z-Wave 0x03 0x36 + 914 Z-Wave 0x04 0x36 + 916 Z-Wave 0x06 0x42 + + + + Reset to factory defaults + + + + + + + + + + + + + + + + + diff --git a/openzwave/kwikset/smartcode.xml b/openzwave/kwikset/smartcode.xml new file mode 100644 index 00000000..3426b3af --- /dev/null +++ b/openzwave/kwikset/smartcode.xml @@ -0,0 +1,390 @@ + + + http://www.openzwave.com/device-database/0090:0001:0001 + images/kwikset/smartcode.png + https://products.z-wavealliance.org/products/945/ + U.S. / Canada / Mexico + 910 + http://www.kwikset.com/Products/Details/Electronic-Locks/910TRL-ZW-15-SMT.aspx + Weiser introduces the SmartCode™ 10 Touchpad Electronic Deadbolt with Z-Wave. + +10 digit backlit keypad with one touch locking +Dramatically reduced, all-metal interior +30 user codes plus master code +BHMA grade 2 certified +20 minute fire rating - UL certified +Full 128-bit encryption security +SmartKey: Re-key the lock in seconds + http://www.kwikset.com/Customer-Support/Overview.aspx + SmartCode 10 Touchpad Electronic Deadbolt + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/157/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/172/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/196/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/605/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/749/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/781/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/945/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1981/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2109/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2188/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2237/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2369/xml + Fixed TriggerRefresh Index to properly update lock status via Access Control. + + https://products.z-wavealliance.org/products/2188/ + Even though the lock is sleeping, all buttons are active and can be used to initiate any lock activity. +For the RF side, it will wake up every 1 second to check if there are any requests from your smart home controller. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2369/Install Guide GED1800 04112017.pdf + 916 + Initiate the process to add the lock to your system at your smart home controller. +When prompted by your smart home system to add the lock, press button “A” on the lock interior one time. The red LED will illuminate when the lock enters Add Mode. +Please allow time for the controller to add the lock to your system. + Follow your smart home system’s instructions to remove the lock from the network. When prompted by the system, press button A” on the lock interior once. The red LED will illuminate when the lock enters Remove mode. + U.S. / Canada / Mexico + A factory reset will delete all user codes associated with the lock and will remove itself from your smart home system. +Please only perform a factory reset when the primary controller is missing or inoperable. + +To perform a factory reset, please perform the following: +1. Remove the battery pack +2. Press and HOLD the Program button while reinserting the battery pack. +3. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red. +4. Press the Program button once more. The status LED will flash green and red several times. +5. After a few seconds, the lock will initiate the door handing process. + https://products.z-wavealliance.org/products/2237/ + U.S. / Canada / Mexico + 914 + https://products.z-wavealliance.org/products/2369/ + GED1800 + U.S. / Canada / Mexico + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + + set the User Code Type for their corresponding user codes. + + + + + + + + Bit mask field that returns the state of the user accessible Dipswitches on the door look. + Bit 0 Lock LED Status (1: enable) + Bit 1 Auto lock (1: enable) + Bit 2 Auto Buzzer (1: enable) + Bit 3 Secure Screen (1: enable) *Only for MB 916 + + + + The Configuration Parameter 33 and 34 are used to set the SKU part numbers to the Kwikset locks. + Is the first four most significant bytes (MSB). + Below describes how Configuration Parameter 33 and 34 are being used. + * For a ZW Configuration Set, the DLM will first do a GET_SKU_ID to retrieve the full SKU from the lock, and the lock will respond with all 8 bytes. (If it not yet set, the DLM will consider that as all 0x30s.) + The DLM changes only the appropriate 4 bytes in its local copy of the SKU, and it then sends the full 8 bytes down to the lock in a SET_SKU_ID. + * For a ZW Configuration Get, the DLM will do a GET_SKU_ID down to the lock, to which the lock will respond with all 8 bytes. + The DLM will return the requested 4 bytes via ZW. If the SKU is not set, it will return all 0x30s (ASCII 0s). + + + + The Configuration Parameter 33 and 34 are used to set the SKU part numbers to the Kwikset locks. + Is the least four significant bytes (LSB). + + + + Unique ID of the lock type + 910 Z-Wave (Legacy, FW 3.4) 0x00 0x00 + 912 Z-Wave (Legacy, FW 3.2) 0x00 0x00 + 910 Z-Wave 0x02 0x36 + 912 Z-Wave 0x03 0x36 + 914 Z-Wave 0x04 0x36 + 916 Z-Wave 0x06 0x42 + + + + Reset to factory defaults + + + + + + + + + + + + + + + + + diff --git a/openzwave/leviton/dz15s.xml b/openzwave/leviton/dz15s.xml new file mode 100644 index 00000000..9a151fbd --- /dev/null +++ b/openzwave/leviton/dz15s.xml @@ -0,0 +1,64 @@ + + + http://www.openzwave.com/device-database/001D:0001:3401 + images/leviton/dz15s.png + https://products.z-wavealliance.org/products/1957/ + When removing a device from a Z-Wave® network best practice is to use the exclusion command found in the Z-Wave® controller. +• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator LED will blink amber. +• Follow directions in the Z-Wave® controller to enter exclusion mode +• Tap the top of the paddle one time. The Locator LED will quickly flash green. +The Z-Wave® controller will exclude the Decora Smart™ device +• The Z-Wave® controller will confirm successful exclusion from the network. + DZ15S + The wireless Leviton DZ15S is a Z-Wave enabled switch designed for use for most residential lighting applications to control LED, CFL, and incandescent bulbs. The DZ15S Switch is fully compatible with Z-Wave Plus certified controllers. Manufacturer Parameters allow custom configuration via Z-Wave commands. Offers manual control to turn lights on/off. Facilitates single pole or three-way multi-location applications. Rated for 600W LED and CFL bulbs, 1800W incandescent bulbs, 15A Fluorescent (at 120 VAC) and 8A (at 277 VAC), 15A Resistive, and 1/2 HP Motor. Requires neutral connection. These Z-Wave Plus devices support beaming, network wide inclusion, and over the air updates. White and Light Almond color faces included, Decora wallplate sold separately. + Leviton Decora Smart™ Z-Wave® devices support two methods of inclusion. When using a Z-Wave Plus® certified controller choose Network Wide Inclusion. +Network Wide Inclusion: +Network Wide Inclusion allows your device to be included into the network using devices already in the network to assist with communication. Work your way from the closest devices to the controller outward. +• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator LED will blink amber. +• Tap the top of the paddle one time. +The Locator LED will quickly flash green. +• The Decora Smart™ Z-Wave® device is ready to learn into the Z-Wave® network. +• Follow directions in the Z-Wave controller to complete the adding process. +• Upon successful addition to network the LED will turn off and then blink green 3 times. +• If the adding process is not successful the LED will flash red 3 times. +Traditional Inclusion: +For older controllers Traditional Inclusion is supported. Depending on the age of the controller the controller will need to be 3 to 35 feet from the device when including. +• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator LED will blink amber. +• The Decora SmartTM Z-Wave® device is ready to add to the Z-Wave® network. +• Follow directions in the Z-Wave® controller to enter learn mode. +• Tap the top of the paddle one time. The Locator LED will quickly flash green. The Z-Wave® controller will begin to pair with the Decora Smart™ device. +• Upon successful addition to the network the LED will turn off and then blink green 3 times. +• If the adding process is not successful the LED will flash red 3 times. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1957/DI-000-DZ15S-02A-X4.pdf + When removing a device from a network it is best practice to use the Exclusion process. In situations where a device needs to be returned to factory default follow the following steps. A reset should only be used when a controller is inoperable or missing. +• Hold the top of the paddle for a total of 14 seconds. +• After the first 7 seconds the LED turns amber. +• The Locator LED will quickly flash red/amber after 14 seconds. +• Release the top of the paddle and the device will reset. + Switch + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1957/xml + Reverts to Revision 3 (before the changes making this almost the DZPA1) - https://products.z-wavealliance.org/products/1957/xml + + + + + + Change the mode of the LED to Status Mode where the LED is illuminated when the load is On, Locator Mode where the LED is illuminated when the Load is Off, or turns off the LED completely for any other setting values. + + + + + + + + + + + + diff --git a/openzwave/leviton/dz6hd.xml b/openzwave/leviton/dz6hd.xml new file mode 100644 index 00000000..942a1dd3 --- /dev/null +++ b/openzwave/leviton/dz6hd.xml @@ -0,0 +1,107 @@ + + + http://www.openzwave.com/device-database/001D:0001:3201 + images/leviton/dz6hd.png + https://products.z-wavealliance.org/products/1910/ + When removing a device from a network it is best practice to use the Exclusion process. In situations where a device needs to be returned to factory default follow the following steps. A reset should only be used when a controller is inoperable or missing. +• Hold the top of the paddle for a total of 14 seconds. +• After the first 7 seconds the LED turns amber. +• The Locator LED will quickly flash red/amber after 14 seconds. +• Release the top of the paddle and the device will reset. + Leviton Decora Smart™ Z-Wave® devices support two methods of inclusion. When using a Z-Wave Plus® certified controller choose Network Wide Inclusion. +Network Wide Inclusion: +Network Wide Inclusion allows your device to be included into the network using devices already in the network to assist with communication. Work your way from the closest devices to the controller outward. +• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator LED will blink amber. +• Tap the top of the paddle one time. +The Locator LED will quickly flash green. +• The Decora Smart™ Z-Wave® device is ready to learn into the Z-Wave® network. +• Follow directions in the Z-Wave controller to complete the adding process. +• Upon successful addition to network the LED will turn off and then blink green 3 times. +• If the adding process is not successful the LED will flash red 3 times. +Traditional Inclusion: +For older controllers Traditional Inclusion is supported. Depending on the age of the controller the controller will need to be 3 to 35 feet from the device when including. +• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator LED will blink amber. +• The Decora SmartTM Z-Wave® device is ready to add to the Z-Wave® network. +• Follow directions in the Z-Wave® controller to enter learn mode. +• Tap the top of the paddle one time. The Locator LED will quickly flash green. The Z-Wave® controller will begin to pair with the Decora Smart™ device. +• Upon successful addition to the network the LED will turn off and then blink green 3 times. +• If the adding process is not successful the LED will flash red 3 times. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1956/DI-000-DZ1KD-02A-X4.pdf + DZ6HD + 1000W Dimmer + The wireless Leviton DZ1KD is a Z-Wave enabled dimmer designed for use for most residential lighting applications to control LED, CFL, and incandescent bulbs. The DZ1KD Dimmer is fully compatible with Z-Wave Plus certified controllers. Provides full range dimming with adjustable fade rates. Manufacturer Parameters allow custom configuration via Z-Wave commands. Offers manual control to turn lights on/off and set brightness level, with an LED feedback to display brightness level. Facilitates single pole or three-way multi-location applications. Rated for 450W LED and CFL dimmable bulbs and 1000W incandescent bulbs, requires neutral connection. These Z-Wave Plus devices support beaming, network wide inclusion, and over the air updates. White and Light Almond color faces included, Decora wallplate sold separately. + U.S. / Canada / Mexico + When removing a device from a Z-Wave® network best practice is to use the exclusion command found in the Z-Wave® controller. +• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator LED will blink amber. +• Follow directions in the Z-Wave® controller to enter exclusion mode +• Tap the top of the paddle one time. The Locator LED will quickly flash green. +The Z-Wave® controller will exclude the Decora Smart™ device +• The Z-Wave® controller will confirm successful exclusion from the network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1910/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1956/xml + + https://products.z-wavealliance.org/products/1956/ + U.S. / Canada / Mexico + DZ1KD + + + + + + The amount of time to take to fade the lights from off to on. + A value of zero is instant (no fade), values between 1 and 127 represent 1 to 127 seconds, and values from 128 to 253 represent from 1 to 126 minutes. + + + + + The amount of time to take to fade the lights from on to off. + A value of zero is instant (no fade), values between 1 and 127 represent 1 to 127 seconds, and values from 128 to 253 represent from 1 to 126 minutes. + + + + Smallest dimming value permitted. + + + Largest dimming value permitted. + + + + The dimming level of the lights when turned from off to on via the switch. + If the value of 0 is used, this means the restore dimming to the last dimming value. + + + + The length of time in seconds that the level indicators should stay illuminated after the dimming level is changed. A value of 0 means the indicator is always off, and a value of 255 means the indicators are always on. + + + + + Change the mode of the LED to Status Mode where the LED is illuminated when the load is On, Locator Mode where the LED is illuminated when the Load is Off, or turns off the LED completely for any other setting values. + + + + + + Specify the type of load that this dimmer controls. + + + + + + + + + + + + + + false + + + diff --git a/openzwave/leviton/dzpa1.xml b/openzwave/leviton/dzpa1.xml new file mode 100644 index 00000000..99298dd8 --- /dev/null +++ b/openzwave/leviton/dzpa1.xml @@ -0,0 +1,67 @@ + + + http://www.openzwave.com/device-database/001d:0001:3601 + images/leviton/dzpa1.png + https://products.z-wavealliance.org/products/1959/ + When removing a device from a Z-Wave® network best practice is to use the exclusion command found in the Z-Wave® controller. +• Enter Programming Mode by holding the control button for 7 seconds, the Locator LED will turn amber. +• Follow directions in the Z-Wave® controller to enter exclusion mode. +• Tap the control button one time. The Locator LED will quickly flash green. +The Z-Wave® controller will exclude the Decora Smart device. +• The Z-Wave® controller will confirm successful exclusion from the network. + DZPA1 + The wireless Leviton DZPA1 is a Z-Wave enabled plug-in outlet designed for use for most residential applications to control plug-in lamps, holiday lighting, or small appliances. The DZPA1 Plug-In Outlet is fully compatible with Z-Wave Plus certified controllers. Offers manual control to turn loads on/off. Manufacturer Parameters allow custom configuration via Z-Wave commands. Rated for 5A LED and CFL bulbs, 1800W incandescent bulbs, 1800W Fluorescent, 15A Resistive, and 1/2 HP Motor. These Z-Wave Plus devices support beaming, network wide inclusion, and over the air updates. + Leviton Decora SmartTM Z-Wave® devices support two methods of inclusion. +When using a Z-Wave PlusTM certified controller choose Network Wide Inclusion. +Network Wide Inclusion: +Network Wide Inclusion allows your device to be added to the network using devices already in the network to assist with communication. Work your way from the closest devices to the controller outward. +• Enter Programming Mode by holding the control button for 7 seconds, the Locator LED will blink amber. +• Tap the control button one time. +The Locator LED will quickly flash green. +• The Decora SmartTM Z-Wave® device is ready to learn into the Z-Wave® network. +• Follow directions in the Z-Wave® controller to complete the adding process. +• Upon successful addition to network the LED will turn off and then blink green 3 times. +• If the adding process is not successful the LED will flash red 3 times. +Traditional Inclusion: +For older controllers Traditional Inclusion is supported. Depending on the age of the controller the controller will need to be 3 to 35 feet from the device when including. +• Enter Programming Mode by holding the control button for 7 seconds, the Locator LED will blink amber. +• The Decora SmartTM Z-Wave® device is ready to add to the Z-Wave® network. +• Follow directions in the Z-Wave® controller to enter learn mode. +• Tap the control button one time. The Locator LED will quickly flash green. +The Z-Wave® controller will begin to pair with the Decora Smart device. +• Upon successful addition to the network the LED will turn off and then blink green 3 times. +• If the adding process is not successful the LED will flash red 3 times. + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1959/DI-000-DZPA1-02B-X4.pdf + When removing a device from a network it is best practice to use the Exclusion process. In situations where a device needs to be returned to factory default follow the following steps. A reset should only be used when a controller is inoperable or missing: +• Holding the control button for a total of 14 seconds. +- After the first 7 seconds the LED turns amber. +- The Locator LED will quickly flash red/amber after 14 seconds. +• Release the control button and the device will reset. + Plug-In Outlet + U.S. / Canada / Mexico + + Fixed incomplete clone of DZ15S to DZPA1 - https://products.z-wavealliance.org/products/1959/xml + + https://products.z-wavealliance.org/products/1959/ + DZPA1 + U.S. / Canada / Mexico + + + + + Change the mode of the LED to Status Mode where the LED is illuminated when the load is On, Locator Mode where the LED is illuminated when the Load is Off, or turns off the LED completely for any other setting values. + + + + + + + + + + + + diff --git a/openzwave/leviton/dzpd3.xml b/openzwave/leviton/dzpd3.xml new file mode 100644 index 00000000..434ba6fa --- /dev/null +++ b/openzwave/leviton/dzpd3.xml @@ -0,0 +1,90 @@ + + + http://www.openzwave.com/device-database/001D:0001:3501 + images/leviton/dzpd3.png + https://products.z-wavealliance.org/products/1958/ + DZPD3 + When removing a device from a Z-Wave® network best practice is to use the exclusion command found in the Z-Wave® controller. +• Enter Programming Mode by holding the control button for 7 seconds, the Locator LED will turn amber. +• Follow directions in the Z-Wave® controller to enter exclusion mode. +• Tap the control button one time. The Locator LED will quickly flash green. +The Z-Wave® controller will exclude the Decora Smart device. +• The Z-Wave® controller will confirm successful exclusion from the network. + Leviton Decora Smart Z-Wave® devices support two methods of inclusion. +When using a Z-Wave Plus certified controller choose Network Wide Inclusion. +Network Wide Inclusion: +Network Wide Inclusion allows your device to be added to the network using devices already in the network to assist with communication. Work your way from the closest devices to the controller outward. +• Enter Programming Mode by holding the control button for 7 seconds, the Locator LED will blink amber. +• Tap the control button one time. +The Locator LED will quickly flash green. +• The Decora Smart Z-Wave® device is ready to learn into the Z-Wave® network. +• Follow directions in the Z-Wave® controller to complete the adding process. +• Upon successful addition to network the LED will turn off and then blink green 3 times. +• If the adding process is not successful the LED will flash red 3 times. +Traditional Inclusion: +For older controllers Traditional Inclusion is supported. Depending on the age of the controller the controller will need to be 3 to 35 feet from the device when including. +• Enter Programming Mode by holding the control button for 7 seconds, the Locator LED will blink amber. +• The Decora Smart Z-Wave® device is ready to add to the Z-Wave® network. +• Follow directions in the Z-Wave® controller to enter learn mode. +• Tap the control button one time. The Locator LED will quickly flash green. +The Z-Wave® controller will begin to pair with the Decora Smart device. +• Upon successful addition to the network the LED will turn off and then blink green 3 times. +• If the adding process is not successful the LED will flash red 3 times. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1958/DI-000-DZPD3-02B-X4.pdf + The wireless Leviton DZPD3 is a Z-Wave enabled plug-in dimmer designed for use for most residential lighting applications to control LED, CFL, and incandescent bulbs. The DZPD3 Dimmer is fully compatible with Z-Wave Plus certified controllers. Provides full range dimming with adjustable fade rates. Manufacturer Parameters allow custom configuration via Z-Wave commands. Rated for 100W LED and CFL dimmable bulbs and 300W incandescent bulbs. These Z-Wave Plus devices support beaming, network wide inclusion, and over the air updates. + When removing a device from a network it is best practice to use the Exclusion process. In +situations where a device needs to be returned to factory default follow the following steps. +A reset should only be used when a controller is inoperable or missing: +• Holding the control button for a total of 14 seconds. +- After the first 7 seconds the LED turns amber. +- The Locator LED will quickly flash red/amber after 14 seconds. +• Release the control button and the device will reset. + U.S. / Canada / Mexico + Plug-In Dimmer + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1958/xml + + + + + + The amount of time to take to fade the lights from off to on. A value of zero is instant (no fade), values between 1 and 127 represent 1 to 127 seconds, and values from 128 to 253 represent from 1 to 126 minutes. + + + + The amount of time to take to fade the lights from on to off. A value of zero is instant (no fade), values between 1 and 127 represent 1 to 127 seconds, and values from 128 to 253 represent from 1 to 126 minutes. + + + + Smallest dimming value permitted. + + + Largest dimming value permitted. + + + Change the mode of the LED to Status Mode where the LED is illuminated when the load is On, Locator Mode where the LED is illuminated when the Load is Off, or turns off the LED completely for any other setting values. + + + + + + Specify the type of load that this dimmer controls. + + + + + + + + + + + + + + false + + + diff --git a/openzwave/leviton/rzi10.xml b/openzwave/leviton/rzi10.xml new file mode 100644 index 00000000..426aa073 --- /dev/null +++ b/openzwave/leviton/rzi10.xml @@ -0,0 +1,8 @@ + + + + + false + + + diff --git a/openzwave/leviton/vrcpg.xml b/openzwave/leviton/vrcpg.xml new file mode 100644 index 00000000..426aa073 --- /dev/null +++ b/openzwave/leviton/vrcpg.xml @@ -0,0 +1,8 @@ + + + + + false + + + diff --git a/openzwave/leviton/vrcs2.xml b/openzwave/leviton/vrcs2.xml new file mode 100644 index 00000000..6c124d6a --- /dev/null +++ b/openzwave/leviton/vrcs2.xml @@ -0,0 +1,21 @@ + + + http://www.openzwave.com/device-database/001D:0206:0201 + images/leviton/vrcs2.png + https://products.z-wavealliance.org/products/288/ + U.S. / Canada / Mexico + The Vizia RF + 4-Button Zone Controller with Switch (VRCZ4-MR) and 4-Button Scene Controller with Switch (VRCS4-MR) are perfect for retrofit applications because they replace an existing switch giving the user control of the local load as well as the benefit of scene or zone control. + Item Description +Vizia RF + 4-Button Zone Controller with Switch for Multi-Location Control with IR Remote Capability. White face assembled on device, ivory and light almond faces included. + http://www.leviton.com/OA_HTML/ProductDetail.jsp?partnumber=VRCZ4-MRZ&section=44147&minisite=10251 + VRCZ4-MR + http://www.leviton.com/OA_HTML/Home.jsp?minisite=10251&respid=22372 + VRCZ4-MR + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/286/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/287/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/288/xml + + + + diff --git a/openzwave/leviton/vrcz4.xml b/openzwave/leviton/vrcz4.xml new file mode 100644 index 00000000..ae76ad4e --- /dev/null +++ b/openzwave/leviton/vrcz4.xml @@ -0,0 +1,18 @@ + + + + + + + + + + + + + + diff --git a/openzwave/leviton/vre06.xml b/openzwave/leviton/vre06.xml new file mode 100644 index 00000000..426aa073 --- /dev/null +++ b/openzwave/leviton/vre06.xml @@ -0,0 +1,8 @@ + + + + + false + + + diff --git a/openzwave/leviton/vrf01.xml b/openzwave/leviton/vrf01.xml new file mode 100644 index 00000000..11e76c15 --- /dev/null +++ b/openzwave/leviton/vrf01.xml @@ -0,0 +1,25 @@ + + + http://www.openzwave.com/device-database/001D:0334:1001 + images/leviton/vrf01.png + https://products.z-wavealliance.org/products/807/ + U.S. / Canada / Mexico + › Preset On Level option sets the fan speed when the device is turned on, regardless of the previous setting +› Off-Low-Medium-High speed settings +› Microprocessor-controlled "kick start" allows fan to go directly from OFF to any speed setting +› LED Locator and fan speed display +› Requires the Vizia RF + Handheld Remote - VRCPG for programming and control of the Vizia RF + System (sold separately) + + Scene Capable Quiet Fan Speed Control + VRF01 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/807/xml + + + + + + false + + + diff --git a/openzwave/leviton/vri06.xml b/openzwave/leviton/vri06.xml new file mode 100644 index 00000000..426aa073 --- /dev/null +++ b/openzwave/leviton/vri06.xml @@ -0,0 +1,8 @@ + + + + + false + + + diff --git a/openzwave/leviton/vri10.xml b/openzwave/leviton/vri10.xml new file mode 100644 index 00000000..1121510b --- /dev/null +++ b/openzwave/leviton/vri10.xml @@ -0,0 +1,20 @@ + + + http://www.openzwave.com/device-database/001D:0334:0602 + images/leviton/vri10.png + https://products.z-wavealliance.org/products/810/ + Magnetic Low Voltage Dimmer + U.S. / Canada / Mexico + Vizia RF + 1000VA Magnetic Low Voltage, 1000W Incandescent and Mark 10 Scene Capable Dimmer for single pole, 3-way or more applications, with LED locator and brightness display. + VRMX1 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/810/xml + + + + + + false + + + diff --git a/openzwave/leviton/vrpa1.xml b/openzwave/leviton/vrpa1.xml new file mode 100644 index 00000000..eb49a642 --- /dev/null +++ b/openzwave/leviton/vrpa1.xml @@ -0,0 +1,41 @@ + + + http://www.openzwave.com/device-database/001D:0334:1805 + images/leviton/vrpa1.png + When removing a device from a Z-Wave® network best practice is to use the exclusion command found in the Z-Wave® controller. +• Enter Programming Mode by holding the control button for 7 seconds, the Locator LED will turn amber. +• Follow directions in the Z-Wave® controller to enter exclusion mode. +• Tap the control button one time. The Locator LED will quickly flash green. +The Z-Wave® controller will exclude the Decora Smart device. +• The Z-Wave® controller will confirm successful exclusion from the network. + VRPA1-15A + The Vizia RF + Scene Capable Plug-in Appliance Module is ideal for any residential setting where remote ON/OFF switching of appliances, motor loads up to 1/2 HP, or freestanding lights, including Incandescent, Magnetic Low Voltage, Fluorescent and Compact Fluorescent loads is needed. Typical applications include switching of fluorescent lamps, portable fans, kitchen appliances, indoor fountains and more. The Vizia RF + Scene Capable Plug-in Appliance Module also allows users to incorporate small appliances into scene and zone home control applications + 1. Plug in the unit + 2. Put your controller in inclusion mode + 3. Press the button on the front of the plug-in module + + 1. Plug in the unit + 1. Put your controller in exclusion mode + 2. Press the button on the front of the plug-in module + + + Plug-In Outlet + U.S. / Canada / Mexico + + Initial update based on dz15s, Leviton documentation, and CD-Jackson's Z-Wave Database + + https://products.z-wavealliance.org/products/1959/ + DZPA1 + U.S. / Canada / Mexico + + + + + + + + + + + + diff --git a/openzwave/leviton/vrpd3.xml b/openzwave/leviton/vrpd3.xml new file mode 100644 index 00000000..102c4743 --- /dev/null +++ b/openzwave/leviton/vrpd3.xml @@ -0,0 +1,37 @@ + + + http://www.openzwave.com/device-database/001D:0334:1706 + images/leviton/vrpd3.png + VRPD3-1LW + The Vizia RF + Scene Capable Plug-in Lamp Dimming Module (VRPD3-1LW) is ideal for any residential setting where remote dimming of Incandescent loads up to 300 Watts CFL/LED loads up to 100W is needed. Typical applications include dimming of table and floor lamps. The Vizia RF + Scene Capable Plug-in Lamp Module also allows users to remotely control free-standing lamps individually or as part of a scene or zone grouping of lights through scene commands. + 1. Plug in Leviton VRPD3 +2. Place controller in inclusion mode +3. Press button on front of VRPD3 + +If successful, the VRPD3 LED will turn orange during inclusion and then green. The LED will flash red if it fails. + + 1. Place controller in exclusion mode +2. Press button on front of VRPD3 + +If successful, the VRPD3 LED will turn orange during exclusion and then green. The LED will flash red if it fails. + 1. Hold the control button for 5 seconds until the LED begins to flash amber +2. Continue holding the control button until the LED turns red +3. The plug-in dimmer module is reset + Scene Capable Plug-in Dimmer + U.S. / Canada / Mexico + + Initial update based on vrpa1, Leviton documentation, and CD-Jackson's Z-Wave Database + + https://products.z-wavealliance.org/products/1958 + + + + + + + + + + + + diff --git a/openzwave/leviton/vrs15.xml b/openzwave/leviton/vrs15.xml new file mode 100644 index 00000000..b82c4dca --- /dev/null +++ b/openzwave/leviton/vrs15.xml @@ -0,0 +1,18 @@ + + + http://www.openzwave.com/device-database/001D:0334:0301 + images/leviton/vrs15.png + https://products.z-wavealliance.org/products/814/ + VRS15 + - Manual and remote ON/OFF control of connected loads +- LED Display options control the length of time they remain lit +- Push pad always returns to a neutral position whether switch is on or off so it maintains a consistent appearance when mixed in a multi-switch wall box +- Compatible with Decora Plus screwless wallplates and Decora wallplates +- Requires the Vizia RF + Handheld Remote - VRCPG for programming and control of the Vizia RF + System (sold separately) + U.S. / Canada / Mexico + Wall Switch, 15A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/814/xml + + + diff --git a/openzwave/leviton/zw4sf.xml b/openzwave/leviton/zw4sf.xml new file mode 100644 index 00000000..ea3c21cc --- /dev/null +++ b/openzwave/leviton/zw4sf.xml @@ -0,0 +1,62 @@ + + + + http://www.openzwave.com/device-database/001D:0002:0038 + images/leviton/zw4sf.png + https://products.z-wavealliance.org/products/3832/ + Factory Default When removing a fan speed controller from a network it is best practice to use the exclusion process. In situations where a device needs to be returned to factory default follow the following steps. A reset should only be used when a controller is inoperable or missing. 1. Hold the top of the paddle for 7 seconds, the status light will turn amber. Continue holding the top paddle for another 7 seconds (total of 14 seconds). The status light will quickly flash red/ amber. 2. Release the top of the paddle and the device will reset. + Classic Inclusion To A Z-Wave Network For older controllers Classic Inclusion is supported. Depending on the age of the controller the controller will need to be 3 to 35 feet from the device when including. 1. To enter programming mode, hold the button for 7 seconds. The status light will turn amber, release and the status light will blink. 2. Follow the Z-Wave controller instructions to enter inclusion mode. 3. Tap the top or the paddle of the paddle one time. The status light will quickly flash green. 4. The Z-Wave controller will confirm successful inclusion to the network. + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3832/Draft%20ZW4SF%203-25-20.pdf + ZW4SF + Fan Speed Controller + 4 Speed Fan controller 120VAC. Compatible with pull chain ceiling fans without electronic control. White paddle and vanishing LEDs. Color change kits are available to change to Light Almond, Ivory, Black, Brown, Gray. + U.S. / Canada / Mexico + Exclusion From A Z-Wave Network When removing an fan speed controller from a Z-Wave network, best practice is to use the exclusion command found in the Z-Wave controller. 1. To enter programming mode, hold the button for 7 seconds. The status light will turn amber, release and the status light will blink. 2. Follow Z-Wave controller directions to enter exclusion mode 3. Tap the the top of the paddle 1 time. The status light will quickly flash green. 4. The Z-Wave controller will remove the device from the network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3832/xml + + https://products.z-wavealliance.org/products/3382/ + U.S. / Canada / Mexico + ZW4SF + + + + + + Minimum Fan Speed level allowed + + + + + Maximum Fan Speed level allowed + + + + Preset Level for On + + + The length of time in seconds that the level indicators should stay illuminated after the dimming level is changed. A value of 0 means the indicator is always off, and a value of 255 means the indicators are always on. + + + + + Change the mode of the LED to Status Mode where the LED is illuminated when the load is On, Locator Mode where the LED is illuminated when the Load is Off, or turns off the LED completely for any other setting values. + + + + + + + + + + + + + + false + + + diff --git a/openzwave/linear/GC-TBZ48.xml b/openzwave/linear/GC-TBZ48.xml new file mode 100644 index 00000000..8bddfff7 --- /dev/null +++ b/openzwave/linear/GC-TBZ48.xml @@ -0,0 +1,257 @@ + + + + + + + 0 + true + + + + + + 0 = Standard, 1 = Heat Pump + + + + + + + 0 = Gas (no fan w/Heat), 1 = Electric (Fan w/Heat) + + + + + + + 0 = w/Cool, 1 = w/Heat + + + + + + + 0 = no 2nd stage heat, 1 = 2nd stage heat + + + + + + + 0 = no aux heat, 1 = aux heat enabled + + + + + + + 0 = no 2nd stage cool, 1 = 2nd stage cool + + + + + + + 0 = Celsius, 1 = Fahrenheit + + + + + + + Sets the Minimum Off Time (MOT) delay before another heating/cooling cycle can begin + + + + + Sets the Minimum Run Time (MRT) delay before a heating/cooling cycle can turn of + + + + + Sets the minimum separation between heating and cooling setpoints + + + + + Sets the delta from setpoint that stage 1 heating starts + + + + + Sets the delta from setpoint that stage 1 heating stops + + + + + Sets the delta from setpoint that stage 2 heating starts + + + + + Sets the delay from setpoint that stage 2 heating stops + + + + + Sets the delta from setpoint that stage 3 heating starts + + + + + Sets the delta from setpoint that stage 3 heating stops + + + + + Sets the delta from setpoint that stage 1 cooling starts + + + + + Sets the delta from setpoint that stage 1 cooling stops + + + + + Sets the delta from setpoint that stage 2 cooling starts + + + + + Sets the delta from setpoint that stage 2 cooling stops + + + + + Report to send to the Lifeline Association Group upon change in thermostat state. + Bitmask values: + 1 = Temperature + 2 = Heat Setpoint + 4 = Cool Setpoint + 8 = Thermostat Heat/Cooling Mode + 16 = Fan Mode + 32 = Fan State + 64 = Operating State + 128 = Schedule (send CC parameter 38) + 256 = Setback (send CC parameter 40) + 512 = Run Hold (send CC parameter 39) + 1024 = Display Lock (send CC parameter 24) + 8192 = Battery Level + 16834 = Mechanical Relay State (send CC parameter 21) + 32768 = Thermostat State Config (send CC parameter 22) + + + + + Display Lock + + + + + + + Sets the time from last button press that the backlight will turn OFF + + + + + Sets the maximum heating setpoint value + + + + + Sets the minimum cooling setpoint value + + + + + Enable or disable thermostat's local scheduler + + + + + + + 0 = Hold, 1 = Run + + + + + + + 0 = No setback, 2 = Un-occupied mode + + + + + + + Heat Setpoint for Unoccupied mode + + + + + Cool Setpoint for Unoccupied mode + + + + + Node number for Remote Sensor 1 + + + + + Temperature of Remote Sensor 1 + + + + + Internal Sensor Temperature Offset + + + + + R1 Sensor Temperature Offset + + + + + Timer to let know when to change or clean the filter + + + + + Maximum allowed value for filter timer + + + + + Heat Timer in hours + + + + + Cool Timer in hours + + + + + Fan purge period for Heat mode + + + + + Fan purge period for Cool mode + + + + + + + + + + + diff --git a/openzwave/linear/LB60Z-1.xml b/openzwave/linear/LB60Z-1.xml new file mode 100644 index 00000000..ead9c14a --- /dev/null +++ b/openzwave/linear/LB60Z-1.xml @@ -0,0 +1,71 @@ + + + http://www.openzwave.com/device-database/014F:3038:4754 + images/linear/LB60Z-1.png + https://products.z-wavealliance.org/products/1414/ + LBR30Z-1 + You may manually reset the light bulb as follows: +1. Flick the wall switch “OFF-ON” 4 times within 4 seconds. +2. The dt Smart Bulb will flash twice after Reset is successful. + +Use this procedure only in the event that the network primary controller is lost or otherwise inoperable. + U.S. / Canada / Mexico + 1. Turn off power to the light bulb socket +2. Follow the network controller instruction to place your network controller into exclusion mode to remove the dt light bulb from the network. +3. After being prompted by the network controller, turn On power to the light bulb. If successful, the LED light bulb will flash twice to indicate successful inclusion. + + + 1. Turn Off power to the light bulb socket +2. Screw in the light bulb +3. Place your network controller into inclusion mode by following the controller manufacturer's instructions +4. Turn On power to the light bulb. If successful, the LED light bulb will flash twice to indicate successful inclusion. +5. If the controller/gateway shows it was a fail, repeat the procedure. + +Note: If Inclusion still fails after the 2nd attempt, you need to first RESET the dt Smart Bulb before repeating the above steps. + + Smart LED Light Bulb + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1414/10006193X8 LBR30Z-1 Instructions.pdf + Smart LED light bulb with Z-Wave radio. +- Control lights remotely and save energy +- Compatible with smart home systems supporting Z-Wave +- 65 Watt equivalent light (650 lumens) +- Consumes only 7.5 watts of power +- 5000K Day light with frosted glass +- Instant ON and fully dimmable +- Functions as a Z-Wave signal repeater +- Very simple to include in your network +- Z-Wave Plus certified + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1162/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1290/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1291/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1414/xml + Updated Configuration Parameters from manufacturer's product data + + + + + + Using Last Dim Setting will bring the bulb back to the last dimness setting when turning on, instead of full brightness by default. + + + + + How much the bulb brightness will change. A low value (1) provides gradual dimming and brightening, a high value (99) makes it change rapidly. + + + + + How fast the bulb brightness will change. When the value is low (1), the step timing is quick. When the value is high (10), the step timing is slow. + + + + + + + + + + + diff --git a/openzwave/linear/PD300Z-2.xml b/openzwave/linear/PD300Z-2.xml new file mode 100644 index 00000000..563df804 --- /dev/null +++ b/openzwave/linear/PD300Z-2.xml @@ -0,0 +1,17 @@ + + + + + + Turn on the module when the attached load is connected. + + + This dimmer will always start dimming from its current level, ignoring any commanded start level. + + + + + + + + diff --git a/openzwave/linear/WA00Z-1.xml b/openzwave/linear/WA00Z-1.xml new file mode 100644 index 00000000..c4f864fc --- /dev/null +++ b/openzwave/linear/WA00Z-1.xml @@ -0,0 +1,23 @@ + + + + + + Set the switch to control other devices or issue various scene activation commands to a central controller. + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. + + + + + + + + + + + diff --git a/openzwave/linear/WA105DBZ-1.xml b/openzwave/linear/WA105DBZ-1.xml new file mode 100644 index 00000000..d8bb98fa --- /dev/null +++ b/openzwave/linear/WA105DBZ-1.xml @@ -0,0 +1,30 @@ + + + + + + Defines the reaction of the siren: [0] Strobe and Siren, [1] Siren, [2] Strobe (Default setting: 0) + + + Defines the auto time out of the alarm indication: [0] 30 seconds, [1] 60 seconds, [2] 120 seconds, [3] Continuous (Default setting: 0) + + + + + + true + + + + + + true + + + + + + true + + + diff --git a/openzwave/linear/WADWAZ-1.xml b/openzwave/linear/WADWAZ-1.xml new file mode 100644 index 00000000..d43540fc --- /dev/null +++ b/openzwave/linear/WADWAZ-1.xml @@ -0,0 +1,28 @@ + + + + + External Switch Status + + + + + + + + true + + + + + + false + + + + + + + + + diff --git a/openzwave/linear/WAPIRZ-1.xml b/openzwave/linear/WAPIRZ-1.xml new file mode 100644 index 00000000..9632035f --- /dev/null +++ b/openzwave/linear/WAPIRZ-1.xml @@ -0,0 +1,19 @@ + + + + + + By default, to conserve battery life, after the WAPIRZ-1 detects motion it cannot be re-triggered by motion again for 3 minutes. + Each time motion is detected (even during this wait time) the 3 minute timer starts over. + The length of the re-trigger wait time can be adjusted with this setting. + + + + + + + + + + + diff --git a/openzwave/linear/WD500Z-1.xml b/openzwave/linear/WD500Z-1.xml new file mode 100644 index 00000000..50437be7 --- /dev/null +++ b/openzwave/linear/WD500Z-1.xml @@ -0,0 +1,22 @@ + + + + + + In night-light mode the LED on the switch will turn ON when the switch is turned OFF, instead of following the state of the load. + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. + + + This dimmer will always start dimming from its current level, ignoring any commanded start level. + + + + + + + + diff --git a/openzwave/linear/WD500Z5-1.xml b/openzwave/linear/WD500Z5-1.xml new file mode 100644 index 00000000..7c1c9b19 --- /dev/null +++ b/openzwave/linear/WD500Z5-1.xml @@ -0,0 +1,77 @@ + + + http://www.openzwave.com/device-database/014F:3530:5744 + images/linear/WD500Z5-1.png + https://products.z-wavealliance.org/products/1883/ + Adding to a Network: +1. With your Controller in Discovery or Add Mode, tap the switch. The LED will blink slowly when in ADD Mode. +2. You should see an indication on your Controller that the “device was added” to the network and the LED will stop blinking. +3. The device will appear in the list of Switches. It should display as a switch. + WD500Z5-1 + To Reset Unit (If Required): +Use only in the event that your primary Controller is lost or otherwise inoperable, to reset the GoControl Dimmer and clear all network information, follow these steps: +1. Tap the top of the switch five (5) times. +2. Press and hold the bottom of the switch for 15 seconds. The LED will increasingly blink faster to indicate that a Reset is taking place. + + + The WD500Z5-1 is an in-wall lighting dimmer switch designed to operate with LED, halogen and incandescent lights. Not only can this switch control the connected load, with Central Scene support it can run up to 6 scenes created by the Hub it is the most versatile Home Automation light switch available. With OTA upgrading supported, this light switch may be the last one ever installed in a home. + WD500Z5-1 + Removing from a Network: +1. Set the Controller into Removal Mode and follow its instruction to delete the GoControl Dimmer from the Controller. +2. Remove the switch by tapping the paddle 2 times. The LED will begin blinking slowly for 10 seconds indicating that it has been removed. +3. You should see an indication on your Controller that the “device was removed” from the network. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1883/10008092X18 WD500Z5-1_WD1000Z5-1 Instructions.pdf + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1883/xml + + + + + + By default, the Dimmer LED will turn OFF when the load attached is turned ON. + + + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. + + + + + This dimmer will always start dimming from its current level, ignoring any commanded start level. + + + + + Dim Step can be set to a value of 1 to 99. This value indicates how many levels the dimmer will change each time the Dim Timer expires. + + + The Dim Timer (how fast the dim steps happen). It can be set to a value of 1 to 255. This value indicates in 10 millisecond resolution, how often the dim level will change. + + + Dim Step can be set to a value of 1 to 99. This value indicates how many levels the dimmer will change each time the Dim Timer expires. + + + The Dim Timer (how fast the dim steps happen). It can be set to a value of 1 to 255. This value indicates in 10 millisecond resolution, how often the dim level will change. + + + Dim Step can be set to a value of 1 to 99. This value indicates how many levels the dimmer will change each time the Dim Timer expires. + + + The Dim Timer (how fast the dim steps happen). It can be set to a value of 1 to 255. This value indicates in 10 millisecond resolution, how often the dim level will change. + + + + + + + + + diff --git a/openzwave/linear/WS15Z-1.xml b/openzwave/linear/WS15Z-1.xml new file mode 100644 index 00000000..c9896a1d --- /dev/null +++ b/openzwave/linear/WS15Z-1.xml @@ -0,0 +1,19 @@ + + + + + + In night-light mode the LED on the switch will turn ON when the switch is turned OFF, instead of following the state of the load. + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. + + + + + + + + diff --git a/openzwave/linear/WT00Z-1.xml b/openzwave/linear/WT00Z-1.xml new file mode 100644 index 00000000..edee5c53 --- /dev/null +++ b/openzwave/linear/WT00Z-1.xml @@ -0,0 +1,33 @@ + + + + + + By default, the LED on the switch will turn OFF when the Associated device is turned ON. + + + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. + + + The associated dimmer will start dimming from its current level, ignoring any commanded start level. + + + Dim Step can be set to a value of 1 to 99. This value indicates how many levels the dimmer will change each time the Dim Timer expires. + + + The Dim Timer (how fast the dim steps happen). It can be set to a value of 1 to 255. This value indicates in 10 millisecond resolution, how often the dim level will change. + + + + + + + + + + diff --git a/openzwave/linear/WT00Z5-1.xml b/openzwave/linear/WT00Z5-1.xml new file mode 100644 index 00000000..b4670aa2 --- /dev/null +++ b/openzwave/linear/WT00Z5-1.xml @@ -0,0 +1,56 @@ + + + Smart 3-Way Switch/Dimmer + The WT00Z5-1 Wall Mount Accessory Dimmer Switch allows remote ON/OFF control and dimming of lights controlled by associated Z-Wave modules, creating virtual 3-way switches. The WT00Z5-1 controls no load directly, so it can be wired anywhere power is available, without the need for a traveler wire. + http://www.openzwave.com/device-database/014f:3530:5754 + https://www.gocontrol.com/detail.php?productId=1782 + https://www.gocontrol.com/support.php + images/linear/WT00Z5-1.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1888/10007350B%20.pdf + Refer to your Controller operating instructions to add this switch under the command of the Wireless Controller. +1. With your Controller in Discovery or Add Mode, tap the switch. The LED will blink slowly when in ADD Mode. +2. You should see an indication on your Controller that the “device was added” to the network and the LED will stop blinking. +3. The device will appear in the list of Switches. It should display as a switch. +If the Controller/Gateway shows the addition failed, repeat Steps 1-3. +NOTE: If you have trouble adding the WT00Z5-1 to a group it may be that the Home ID and Node ID were not cleared from it after testing. You must first “RESET UNIT” to remove it from the network. Although adding it to a group includes it in the network, removing it from a group does not remove it from the network. If removed from a group, it functions as a repeater (only). “RESET UNIT” removes it completely from the network. + The WT00Z5-1 can be removed from the network by the Controller/Gateway. Refer to the Controller operating instructions for details. +1. Set the Controller into Removal Mode and follow its instruction to delete the WT00Z5-1 from the Controller. +2. Remove the switch by tapping the paddle 2 times. The LED will begin blinking slowly for 10 seconds indicating that it has been removed. +3. You should see an indication on your Controller that the “device was removed” from the network. + In the event that your primary Controller is lost or otherwise inoperable, to reset the WT00Z5-1 and clear all network information, follow these steps: +1. Tap the top of the switch five (5) times. +2. Press and hold the bottom of the switch for 15 seconds. The LED will increasingly blink faster to indicate that a Reset is taking place. + https://products.z-wavealliance.org/products/1888 + U.S. / Canada / Mexico + WT00Z5-1 + + Initial entry with data obtained from https://products.z-wavealliance.org/products/1888 + + + + + + By default, the LED on the WT00Z5-1 will turn OFF when the Associated device is turned ON. + + + + + + + + + + Change the top of the switch to OFF and the bottom of the switch to ON. + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/linear/gd00z-7.xml b/openzwave/linear/gd00z-7.xml new file mode 100644 index 00000000..f4d1b36d --- /dev/null +++ b/openzwave/linear/gd00z-7.xml @@ -0,0 +1,22 @@ + + + http://www.openzwave.com/device-database/014F:3531:4744 + images/linear/gd00z-7.png + https://products.z-wavealliance.org/products/2904/ + Z-Wave Garage Door Controller + 1. Place your Z-Wave Controller into Exclude mode. +2. Press and release the link button on the GD00Z-6. + 1. Place your Z-Wave Controller into Include mode. +2. Press and release the link button on the GD00Z-6. + U.S. / Canada / Mexico + GD00Z-6 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2904/10015084AX1 UG.pdf + The GoControl GD00Z-6 is the next iteration of the best selling line of Z-Wave controlled remote garage door status indicator and activator. Adding S2 security and OTA capability, the GD00Z-6 continues to Nortek’s leadership positing in the IOT market. Open or close a sectional garage door remotely through a Z-Wave certified Gateway or Security Panel. Compatible with virtually any garage door opener connected to a sectional garage door. Audible and visual warnings prior to remotely-activated door movement, meeting UL 325 safety requirements. Included tilt sensor reports door "open" or "close" information. + Reset the GD00Z-6 by pressing the LINK button 5 times. A quick beep followed by a longer beep will indicate the reset. +Reset should only be used in the case of a missing or inoperative primary controller. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2635/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2904/xml + + + diff --git a/openzwave/linear/ngd00z.xml b/openzwave/linear/ngd00z.xml new file mode 100644 index 00000000..103fd92e --- /dev/null +++ b/openzwave/linear/ngd00z.xml @@ -0,0 +1,20 @@ + + + http://www.openzwave.com/device-database/014F:3530:4744 + images/linear/ngd00z.png + https://products.z-wavealliance.org/products/1458/ + n/a + With the hub in "Remove" mode, press the release the button on the side of the GD00Z. + U.S. / Canada / Mexico + With the hub in "Add" mode, press the release the button on the side of the GD00Z. + GD00Z-4 + GD00Z-4 + Garage Door Remote Controller Accessory opens or closes a sectional garage door remotely through a Z-Wave certified Gateway or Security Panel. Compatible with virtually any garage door opener connected to a sectional garage door. Audible and visual warnings prior to remotely-activated door movement, meeting UL 325 safety requirements. Included tilt sensor reports door "open" or "close" information. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1458/236956BX1 GD00Z-4 GoControl Instructions.pdf + Press and release the button in the side of the unit 5 times within 10 seconds only when the primary controller is not available. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1298/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1458/xml + + + diff --git a/openzwave/logicsoft/ZDB5100.xml b/openzwave/logicsoft/ZDB5100.xml new file mode 100644 index 00000000..5e5eb9e1 --- /dev/null +++ b/openzwave/logicsoft/ZDB5100.xml @@ -0,0 +1,503 @@ + + + + Matrix + MATRIX ZDB5100 is a dimmer wall switch module with four backlit pushbuttons. MATRIX is designed to fit into 1-module FUGA® wall boxes (Danish standard). + http://www.openzwave.com/device-database/0234:0121:0003 + https://logic-group.com/products/matrix-switches/ + https://logic-group.com/contact/ + images/logicsoft/ZDB5100.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/3399/MATRIX_ZDB5100_User_Manual_1_01-EN.pdf + MATRIX’add/remove function is initiated by pressing a single time on the smallpushbutton(I) in the middle of the module (under the tangent cover), and the LED’s inpushbutton1 will start blinking. + MATRIX’add/remove function is initiated by pressing a single time on the smallpushbutton(I) in the middle of the module (under the tangent cover), and the LED’s inpushbutton1 will start blinking. + MATRIX can be factory reset by holding the smallpushbutton(I) in the middle of the module under the tangent cover, for at least 10 seconds. + https://products.z-wavealliance.org/products/3399 + CEPT (Europe) + ZDB5100 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3399/xml + + + + + + This parameter specifies which pushbutton(s) that shall be used to control the built-in dimmer. + + + + + + + + + This parameter specifies the duration ofa full regulation of the light from 0% to 100%. + 0: Immediately. + 1-127: Durationin seconds (Default is 5 seconds). + 128-255: Duration in minutes (minus 127) from 1 –128 minutes, where 128 is 1 minute. + + + + + This parameter specifies the duration when turning the light on or off. + 0: Immediately. (Default). + 1-127: Time in seconds. + 128-255: Time in minutes (minus 127) from 1 –128 minutes, where 128 is 1 minute. + + + + The dimmer can work in three different modes: on/off, leading edge or trailing edge. + + + + + + This parameter specifies the actual level of the dimmer output when set to 0%. + + + This parameter specifies the actual level of the dimmer output when set to 99%. + + + This parameter can be used for disabling Central Scene notifications. + + + + + This parameter specifies the reaction when double-activating the pushbuttons. + + + + + + This parameter can be used for enabling the enhanced LED control. See document about MATRIX enhanced LED control. + + + + + + Pushbutton input debounce time in 0.01 seconds resolution. + 1-255: 1–2.55 seconds. Default is 5, which equals to a debounce-filter on 50 milliseconds (0.05 seconds). + + + + + Specifies the time that apushbuttonmust be activated before it is detected as pressed. Resolution is in 0.01 seconds. + 1-255: 1–2.55 seconds. Default is 20, which equals to 200 milliseconds (0.2 seconds). + + + + + Specifies the time that a pushbutton must have been activated before it is accepted as “held-down”. Resolution is 0.01 seconds. + 1-255: 1–2.55 seconds. Default is 50, which equals to 500 milliseconds (0,5 seconds). + + + + + Byte 1: Red brightness + 0-255 Brightness level for the red colour in the 4 indicator groups (Default is 255). + Byte 2: Green brightness + 0–255 Brightness level for the green colour in the 4 indicator groups (Default is 255). + Byte 3: Blue brightness + 0-255 Brightness level for the blue colour in the 4 indicator groups (Default is 255). + Byte 4: Not used–must be set to 0. + Default: 4294967040 + + + + This parameter specifies if commands are transmitted as a secure message for each of the association groups. + Bitmask: + 0: All messages in all groups are sent as insecure. + 1: Messages in association group 2 aresent as secure. + 2: Messages in association group 3 aresent as secure. + 4: Messages in association group 4 aresent as secure. + 8: Messages in association group 5 aresent as secure. + 16: Messages in association group 6 aresent as secure. + 32: Messages in association group 7 aresent as secure. + 64: Messages in association group 8 aresent as secure. + 128: Messages in association group 9 aresent as secure. + 256: Messages in association group 10 aresent as secure. + 512: Messages in association group 11 aresent as secure. + 1024: Messages in association group 12 aresent as secure. + 2048: Messages in association group 13 aresent as secure. + 4096: Messages in association group 14 aresent as secure. + 8191: Messages in allassociation groups are sent as secure. (Default) + + + + All messages in all groups are sent as insecure. + + + + Messages in association group 2 are sent as secure. + + + + Messages in association group 3 are sent as secure. + + + + Messages in association group 4 are sent as secure. + + + + Messages in association group 5 are sent as secure. + + + + Messages in association group 6 are sent as secure. + + + + Messages in association group 7 are sent as secure. + + + + Messages in association group 8 are sent as secure. + + + + Messages in association group 9 are sent as secure. + + + + Messages in association group 10 are sent as secure. + + + + Messages in association group 11 are sent as secure. + + + + Messages in association group 12 are sent as secure. + + + + Messages in association group 13 are sent as secure. + + + + Messages in association group 14 are sent as secure. + + + + Messages in all association groups are sent as secure. + + + + This parameter specifies the functionality of pushbutton 1. + + + + + + + + 0–43200: Specifies the time in seconds. Default is 300 = 5 minutes. + + + + Byte 1: Enable/ Disable + 0 Disabled – A single activation of the pushbutton will not send commands to devices in association group 4. + 1 Enabled – A single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (Default). + Byte 2: Upper switch value + 0–99, 255 When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 255). + Byte 3: Lower switch value + 0-99 When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 0). + Byte 4: Not used–must be set to 0. + Default: 33488896 + + + + This parameter specifies how received Binary Switch Setcommands are handled. + + + + + + This parameter specifies how the LED indication is controlled.. + + + + + + + + + + + This parameter specifies how received Binary Switch Set commands are handled. + + + + + + + Byte 1: Colour saturation, red + 0-255 Specifies the saturation for the red LEDs (Default is 0). + Byte 2: Colour saturation, green + 0–255 Specifies the saturation for the green LEDs (Default is 0). + Byte 3: Colour saturation, blue + 0-255 Specifies the saturation for the blue LEDs (Default is 127). + Byte 4: LED control + 0-255 LED indicator control - see the application note about this parameter (Default is 0). + Default: 32512 + + + + + Byte 1: Colour saturation, red + 0-255 Specifies the saturation for the red LEDs (Default is 47). + Byte 2: Colour saturation, green + 0–255 Specifies the saturation for the green LEDs (Default is 47). + Byte 3: Colour saturation, blue + 0-255 Specifies the saturation for the blue LEDs (Default is 47). + Byte 4: LED control + 0-255 LED indicator control - see the application note about this parameter (Default is 0). + Default: 50065152 + + + + This parameter specifies the functionality of pushbutton 2. + + + + + + + + 0–43200: Specifies the time in seconds. Default is 300 = 5 minutes. + + + + Byte 1: Enable/ Disable + 0 Disabled – A single activation of the pushbutton will not send commands to devices in association group 4. + 1 Enabled – A single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (Default). + Byte 2: Upper switch value + 0–99, 255 When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 255). + Byte 3: Lower switch value + 0-99 When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 0). + Byte 4: Not used–must be set to 0. + Default: 33488896 + + + + This parameter specifies how received Binary Switch Set commands are handled. + + + + + + This parameter specifies how the LED indication is controlled.. + + + + + + + + + + + This parameter specifies how received Binary Switch Setcommands are handled. + + + + + + + Byte 1: Colour saturation, red + 0-255 Specifies the saturation for the red LEDs (Default is 0). + Byte 2: Colour saturation, green + 0–255 Specifies the saturation for the green LEDs (Default is 0). + Byte 3: Colour saturation, blue + 0-255 Specifies the saturation for the blue LEDs (Default is 127). + Byte 4: LED control + 0-255 LED indicator control - see the application note about this parameter (Default is 0). + Default: 32512 + + + + + Byte 1: Colour saturation, red + 0-255 Specifies the saturation for the red LEDs (Default is 47). + Byte 2: Colour saturation, green + 0–255 Specifies the saturation for the green LEDs (Default is 47). + Byte 3: Colour saturation, blue + 0-255 Specifies the saturation for the blue LEDs (Default is 47). + Byte 4: LED control + 0-255 LED indicator control - see the application note about this parameter (Default is 0). + Default: 50065152 + + + + This parameter specifies the functionality of pushbutton 3. + + + + + + + + 0–43200: Specifies the time in seconds. Default is 300 = 5 minutes. + + + + Byte 1: Enable/ Disable + 0 Disabled – A single activation of the pushbutton will not send commands to devices in association group 4. + 1 Enabled – A single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (Default). + Byte 2: Upper switch value + 0–99, 255 When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 255). + Byte 3: Lower switch value + 0-99 When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 0). + Byte 4: Not used–must be set to 0. + Default: 33488896 + + + + This parameter specifies how received Binary Switch Set commands are handled. + + + + + + This parameter specifies how the LED indication is controlled.. + + + + + + + + + + + This parameter specifies how received Binary Switch Setcommands are handled. + + + + + + + Byte 1: Colour saturation, red + 0-255 Specifies the saturation for the red LEDs (Default is 0). + Byte 2: Colour saturation, green + 0–255 Specifies the saturation for the green LEDs (Default is 0). + Byte 3: Colour saturation, blue + 0-255 Specifies the saturation for the blue LEDs (Default is 127). + Byte 4: LED control + 0-255 LED indicator control - see the application note about this parameter (Default is 0). + Default: 32512 + + + + + Byte 1: Colour saturation, red + 0-255 Specifies the saturation for the red LEDs (Default is 47). + Byte 2: Colour saturation, green + 0–255 Specifies the saturation for the green LEDs (Default is 47). + Byte 3: Colour saturation, blue + 0-255 Specifies the saturation for the blue LEDs (Default is 47). + Byte 4: LED control + 0-255 LED indicator control - see the application note about this parameter (Default is 0). + Default: 50065152 + + + + This parameter specifies the functionality of pushbutton 4. + + + + + + + + 0–43200: Specifies the time in seconds. Default is 300 = 5 minutes. + + + + Byte 1: Enable/ Disable + 0 Disabled – A single activation of the pushbutton will not send commands to devices in association group 4. + 1 Enabled – A single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (Default). + Byte 2: Upper switch value + 0–99, 255 When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 255). + Byte 3: Lower switch value + 0-99 When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 0). + Byte 4: Not used–must be set to 0. + Default: 33488896 + + + + This parameter specifies how received Binary Switch Set commands are handled. + + + + + + This parameter specifies how the LED indication is controlled.. + + + + + + + + + + + This parameter specifies how received Binary Switch Setcommands are handled. + + + + + + + Byte 1: Colour saturation, red + 0-255 Specifies the saturation for the red LEDs (Default is 0). + Byte 2: Colour saturation, green + 0–255 Specifies the saturation for the green LEDs (Default is 0). + Byte 3: Colour saturation, blue + 0-255 Specifies the saturation for the blue LEDs (Default is 127). + Byte 4: LED control + 0-255 LED indicator control - see the application note about this parameter (Default is 0). + Default: 32512 + + + + + Byte 1: Colour saturation, red + 0-255 Specifies the saturation for the red LEDs (Default is 47). + Byte 2: Colour saturation, green + 0–255 Specifies the saturation for the green LEDs (Default is 47). + Byte 3: Colour saturation, blue + 0-255 Specifies the saturation for the blue LEDs (Default is 47). + Byte 4: LED control + 0-255 LED indicator control - see the application note about this parameter (Default is 0). + Default: 50065152 + + + + + + + false + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/logicsoft/ZHC5002.xml b/openzwave/logicsoft/ZHC5002.xml new file mode 100644 index 00000000..c0dd7821 --- /dev/null +++ b/openzwave/logicsoft/ZHC5002.xml @@ -0,0 +1,234 @@ + + + + + + + Configuration of Pair Mode for the upper two buttons (Button #1 and #2) + + + + + Configuration of Pair Mode for the middle two buttons (Button #3 and #4) + + + + + Configuration of Pair Mode for the lower two buttons (Button #5 and #6) + + + + + Configuration of the internal operation of LED #1 + + + + + + + + + + + Configuration of the internal operation of LED #2 + + + + + + + + + + + Configuration of the internal operation of LED #3 + + + + + + + + + + + Configuration of the internal operation of LED #4 + + + + + + + + + + + Configuration of the internal operation of LED #5 + + + + + + + + + + + Configuration of the internal operation of LED #6 + + + + + + + + + + + This parameter configures which of the buttons that shall control the built-in relay, or if the relay only will be activated for one second, each time button #1 is used + + + + + + + + + + + Disables or enables the sending of Central Scene notifications + + + + + Disables or enables that a double-press on a button wil send a command to activate 100% light + + + + + + Byte 1: Enable / Disable 0 = Disabled - When single pressing the button, nodes associated to group 6 wont be switched. 1 = Enabled - When single pressing the button, nodes associated to group 6 will be switched between the configured upper and lower switch values. (Default) + Byte 2: Upper switch value: 0 - 99, 255; When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) + Byte 3: Lower switch value: 0 - 99; When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) + Byte 4: Not used - must be set to 0. + + + + + Byte 1: Enable / Disable 0 = Disabled - When single pressing the button, nodes associated to group 6 wont be switched. 1 = Enabled - When single pressing the button, nodes associated to group 6 will be switched between the configured upper and lower switch values. (Default) + Byte 2: Upper switch value: 0 - 99, 255; When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) + Byte 3: Lower switch value: 0 - 99; When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) + Byte 4: Not used - must be set to 0. + + + + + Byte 1: Enable / Disable 0 = Disabled - When single pressing the button, nodes associated to group 6 wont be switched. 1 = Enabled - When single pressing the button, nodes associated to group 6 will be switched between the configured upper and lower switch values. (Default) + Byte 2: Upper switch value: 0 - 99, 255; When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) + Byte 3: Lower switch value: 0 - 99; When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) + Byte 4: Not used - must be set to 0. + + + + + Byte 1: Enable / Disable 0 = Disabled - When single pressing the button, nodes associated to group 6 wont be switched. 1 = Enabled - When single pressing the button, nodes associated to group 6 will be switched between the configured upper and lower switch values. (Default) + Byte 2: Upper switch value: 0 - 99, 255; When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) + Byte 3: Lower switch value: 0 - 99; When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) + Byte 4: Not used - must be set to 0. + + + + + Byte 1: Enable / Disable 0 = Disabled - When single pressing the button, nodes associated to group 6 wont be switched. 1 = Enabled - When single pressing the button, nodes associated to group 6 will be switched between the configured upper and lower switch values. (Default) + Byte 2: Upper switch value: 0 - 99, 255; When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) + Byte 3: Lower switch value: 0 - 99; When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) + Byte 4: Not used - must be set to 0. + + + + + Byte 1: Enable / Disable 0 = Disabled - When single pressing the button, nodes associated to group 6 wont be switched. 1 = Enabled - When single pressing the button, nodes associated to group 6 will be switched between the configured upper and lower switch values. (Default) + Byte 2: Upper switch value: 0 - 99, 255; When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) + Byte 3: Lower switch value: 0 - 99; When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) + Byte 4: Not used - must be set to 0. + + + + Enable or disable if received commands are relayed to the nodes in the assosiation groups + + + + + Enable or disable if received commands are relayed to the nodes in the assosiation groups + + + + + Enable or disable if received commands are relayed to the nodes in the assosiation groups + + + + + Enable or disable if received commands are relayed to the nodes in the assosiation groups + + + + + Enable or disable if received commands are relayed to the nodes in the assosiation groups + + + + + Enable or disable if received commands are relayed to the nodes in the assosiation groups + + + + + Configuration of backlight control + + + + + Enable or disable that Basic Set commands to the root device will be able to control the backlight + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/logicsoft/ZHC5010.xml b/openzwave/logicsoft/ZHC5010.xml new file mode 100644 index 00000000..62e99660 --- /dev/null +++ b/openzwave/logicsoft/ZHC5010.xml @@ -0,0 +1,343 @@ + + + http://www.openzwave.com/device-database/0234:010A:0003 + images/logicsoft/ZHC5010.png + https://products.z-wavealliance.org/products/1779/ + Wall Switch + CEPT (Europe) + ZHC5010 can be factory reset by pressing the small button in the middle of the module (normally covered by small plastic cover) for at least 10 seconds. Please use this procedure only when the network primary controller is missing or otherwise inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1779/ZHC5010-Manual-EN-Rev11.pdf + Pushing the upper left button 3 times, (triple click) will activate Inclusion Mode on the device. It is also possible to activate Inclusion Mode by triple clicking the switch in the middle of the module (normally covered by the middle plastic cover, this can be removed by means of a little screwdriver). + Pushing the upper left button 3 times, (triple click) will activate Exclusion Mode on the device. It is also possible to activate Exclusion Mode by triple clicking the switch in the middle of the module (normally covered by the middle plastic cover, this can be removed by means of a little screwdriver). + ZHC5010 + ZHC5010 is a wall switch module with four buttons, four LEDs, a built-in relay switch and is designed to fit into standard Danish LK FUGA® wall boxes. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1779/xml + + + + + Configuration of Pair Mode for the upper two buttons (button #1 and #2). + + + + + Configuration of Pair Mode for the lower two buttons (button #3 and #4). + + + + + LED #1 indicates the status mode. + + + + + + + + + + + + LED #2 indicates the status mode. + + + + + + + + + + + + LED #3 indicates the status mode. + + + + + + + + + + + + LED #4 indicates the status mode. + + + + + + + + + + + + 0 - 100 Specifies the brightness level of the LED when it is on. + + + 0 - 100 Specifies the brightness level of the LED when it is on. + + + 0 - 100 Specifies the brightness level of the LED when it is on. + + + 0 - 100 Specifies the brightness level of the LED when it is on. + + + 0 - 100 Specifies the brightness level of the LED when it is off. + + + 0 - 100 Specifies the brightness level of the LED when it is off. + + + 0 - 100 Specifies the brightness level of the LED when it is off. + + + 0 - 100 Specifies the brightness level of the LED when it is off. + + + This parameter configures which of the buttons that shall control the built-in relay, or if the relay only will be activated for one second, each time button #1 is used. + + + + + + + + + + + + + + + + + When ZHC5010 receives an Indicator Set message, then the received value can be used only to set the current light level for the actual LED or the level value can be stored and will then be used for subsequent internal activations. + + + + + + 0 : Scene notifications are turned off. + 1-200 : Button #1 will send scene [value], button #2 will send scene [value] + 1, button #3 will send scene [value] + 2, button #4 will send scene [value] + 3 + + + + This parameter is able to enable or disable the so-called "House Cleaning Mode", where ZHC5010 is able send a dimming command in order to set the level of the lights to 100%. + + + + + + Byte 1: Enable / Disable + 0: Disabled - When single pressing the button, nodes associated to group 6 won't be switched + 1: Enabled - When single pressing the button, nodes associated to group 6 will be switched between the configured upper and lower switch values. (Default) + Byte 2: Upper Switch Value + 0 - 99, 255 When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) + Byte 3: Lower Switch Value + When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) + Byte 4: Not used - must be set to 0. + Default: 33488896 + + + + + Byte 1: Enable / Disable + 0: Disabled - When single pressing the button, nodes associated to group 6 won't be switched + 1: Enabled - When single pressing the button, nodes associated to group 6 will be switched between the configured upper and lower switch values. (Default) + Byte 2: Upper Switch Value + 0 - 99, 255 When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) + Byte 3: Lower Switch Value + When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) + Byte 4: Not used - must be set to 0. + Default: 33488896 + + + + + Byte 1: Enable / Disable + 0: Disabled - When single pressing the button, nodes associated to group 6 won't be switched + 1: Enabled - When single pressing the button, nodes associated to group 6 will be switched between the configured upper and lower switch values. (Default) + Byte 2: Upper Switch Value + 0 - 99, 255 When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) + Byte 3: Lower Switch Value + When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) + Byte 4: Not used - must be set to 0. + Default: 33488896 + + + + + Byte 1: Enable / Disable + 0: Disabled - When single pressing the button, nodes associated to group 6 won't be switched + 1: Enabled - When single pressing the button, nodes associated to group 6 will be switched between the configured upper and lower switch values. (Default) + Byte 2: Upper Switch Value + 0 - 99, 255 When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) + Byte 3: Lower Switch Value + When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) + Byte 4: Not used - must be set to 0. + Default: 33488896 + + + + Enable or disable if received commands are relayed to the nodes in the association groups received by device 1. + + + + + Enable or disable if received commands are relayed to the nodes in the association groups received by device 2. + + + + + Enable or disable if received commands are relayed to the nodes in the association groups received by device 3. + + + + + Enable or disable if received commands are relayed to the nodes in the association groups received by device 4. + + + + + + + Decides the time for when a button is detected as long-pressed. + 0 : Detection disabled. This is not recommended. + 1-255 : Long-press detection time in 0.01 seconds, 50 equals 0.5 seconds. + + + + + Specifies the detection time for single-press, double-press, etc. for button 1. + 0 : Detection disabled. This is not recommended. + 1 - 255 : Detection time in 0.01 seconds, 30 equals 0.3 seconds. + Default: 30 + + + + + Specifies the detection time for single-press, double-press, etc. for button 2. + 0 : Detection disabled. This is not recommended. + 1 - 255 : Detection time in 0.01 seconds, 30 equals 0.3 seconds. + Default: 30 + + + + + Specifies the detection time for single-press, double-press, etc. for button 3. + 0 : Detection disabled. This is not recommended. + 1 - 255 : Detection time in 0.01 seconds, 30 equals 0.3 seconds. + Default: 30 + + + + + Specifies the detection time for single-press, double-press, etc. for button 4. + 0 : Detection disabled. This is not recommended. + 1 - 255 : Detection time in 0.01 seconds, 30 equals 0.3 seconds. + Default: 30 + + + + + If ZHC5010 is included secure, this parameter allows sending messages on keypresses to non-secure devices (e.g. pre-gen5 relays). + If ZHC5010 is included non-secure, this parameter has no function. + 0 : No commands sent unencrypted (default) + 1 (0x01) : Bit#1. Not used. + 2 (0x02) : Bit#2. Send BASICREPORT to association group 2 unencrypted. + 4 (0x04) : Bit#3. Send BASICSET to association group 3 unencrypted. + 8 (0x08) : Bit#4. Send BINARYSWITCHSET to association group 4 unencrypted. + 16 (0x10) : Bit#5. Send BINARYTOGGLESWITCHSET to association group 5 unencrypted. + 32 (0x20) : Bit#6. Send MULTILEVELSWITCH to association group 6 unencrypted. + + + + + If ZHC5010 is included secure, this parameter allows sending messages on keypresses to non-secure devices (e.g. pre-gen5 relays). + If ZHC5010 is included non-secure, this parameter has no function. + 0 : No commands sent unencrypted (default) + 1 (0x01) : Bit#1. Not used. + 2 (0x02) : Bit#2. Send BASICREPORT to association group 2 unencrypted. + 4 (0x04) : Bit#3. Send BASICSET to association group 3 unencrypted. + 8 (0x08) : Bit#4. Send BINARYSWITCHSET to association group 4 unencrypted. + 16 (0x10) : Bit#5. Send BINARYTOGGLESWITCHSET to association group 5 unencrypted. + 32 (0x20) : Bit#6. Send MULTILEVELSWITCH to association group 6 unencrypted. + + + + + If ZHC5010 is included secure, this parameter allows sending messages on keypresses to non-secure devices (e.g. pre-gen5 relays). + If ZHC5010 is included non-secure, this parameter has no function. + 0 : No commands sent unencrypted (default) + 1 (0x01) : Bit#1. Not used. + 2 (0x02) : Bit#2. Send BASICREPORT to association group 2 unencrypted. + 4 (0x04) : Bit#3. Send BASICSET to association group 3 unencrypted. + 8 (0x08) : Bit#4. Send BINARYSWITCHSET to association group 4 unencrypted. + 16 (0x10) : Bit#5. Send BINARYTOGGLESWITCHSET to association group 5 unencrypted. + 32 (0x20) : Bit#6. Send MULTILEVELSWITCH to association group 6 unencrypted. + + + + + If ZHC5010 is included secure, this parameter allows sending messages on keypresses to non-secure devices (e.g. pre-gen5 relays). + If ZHC5010 is included non-secure, this parameter has no function. + 0 : No commands sent unencrypted (default) + 1 (0x01) : Bit#1. Not used. + 2 (0x02) : Bit#2. Send BASICREPORT to association group 2 unencrypted. + 4 (0x04) : Bit#3. Send BASICSET to association group 3 unencrypted. + 8 (0x08) : Bit#4. Send BINARYSWITCHSET to association group 4 unencrypted. + 16 (0x10) : Bit#5. Send BINARYTOGGLESWITCHSET to association group 5 unencrypted. + 32 (0x20) : Bit#6. Send MULTILEVELSWITCH to association group 6 unencrypted. + + + + + + + false + + + + + + true + + + + + + true + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/manufacturer_specific.xml b/openzwave/manufacturer_specific.xml new file mode 100644 index 00000000..7f1480df --- /dev/null +++ b/openzwave/manufacturer_specific.xml @@ -0,0 +1,2031 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/manufacturer_specific.xsd b/openzwave/manufacturer_specific.xsd new file mode 100644 index 00000000..94816028 --- /dev/null +++ b/openzwave/manufacturer_specific.xsd @@ -0,0 +1,42 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/mcohome/a8-9.xml b/openzwave/mcohome/a8-9.xml new file mode 100644 index 00000000..3ad9a78f --- /dev/null +++ b/openzwave/mcohome/a8-9.xml @@ -0,0 +1,171 @@ + + + + + + + + =0 Turn off report + >=2 Report when change > + n * 1ug/m3 + + + + + =0 Turn off report + >=2 Report when change > + n * 5ppm + + + + + =0 Turn off report + >=1 Report when change > + n * 0.5 C + + + + + =0 Turn off report + >=3 Report when change > n% + + + + + + + + + =0 Turn off report + >=20 Report when change > + n * 1 lux + + + + + =0 Turn off report + >=5 Report when change > + n * 1dB + + + + + + + + + + + + + =0 Turn off report + >10 Report every n * 1s interval + + + + + =0 Turn off report + >10 Report every n * 1s interval + + + + + =0 Turn off report + >10 Report every n * 1s interval + + + + + =0 Turn off report + >10 Report every n * 1s interval + + + + + =0 Turn off report + >10 Report every n * 1s interval + + + + + =0 Turn off report + >10 Report every n * 1s interval + + + + + =0 Turn off report + >10 Report every n * 1s interval + + + + + =0 Turn off report + >10 Report every n * 1s interval + + + + + =0 Turn off report + >10 Report every n * 1s interval + + + + + + + + + 0 ~ 200 + -10.0 ~ 10.0C + + + + + 0 ~ 40 + -20.0 ~ 20.0% + + + + + 0 ~ 1000 + -500 ~ 500ppm + + + + + 0 ~ 200 + -100 ~ 100ug/m3 + + + + + 0 ~ 10000 + -5000 ~ 5000lux + + + + + 0 ~ 10 + -5 ~ 5 + + + + + 0 ~ 100 + -50 ~ 50 + + + + + + + + + + + + + + + diff --git a/openzwave/mcohome/mh7h.xml b/openzwave/mcohome/mh7h.xml new file mode 100644 index 00000000..7e8231ed --- /dev/null +++ b/openzwave/mcohome/mh7h.xml @@ -0,0 +1,107 @@ + + + http://www.openzwave.com/device-database/015F:5102:0702 + images/mcohome/mh7h.png + https://products.z-wavealliance.org/products/2900/ + Heating Thermostat + CEPT (Europe) + In normal working interface, press & hold S4 to enter interface for adding or removing of Z-Wave network. Before device removed from network, a Node ID will display on the screen. Then press S4 once. If removing is succeed, “- - -”will display on the screen in a few seconds. + +A node ID can always inform us whether the device is in the network or not.When removed, the device will restore its factory setting. + + A parameter P18 in the secret menu can be used to restore factory setting locally. Please use this procedure only when the network primary controller is missing or otherwise inoperable. ; And a parameter FF can be used to restore the factory setting via Z-Wave. + MH7H-WH/EH + MH7H-WH is mainly applied to control wall mounted boiler, water valve/pump etc. , while MH7H-EH is for electrical heating system.The device is of high reliability and practicability, which can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. + +Features: + Capacitive touch buttons + Tempered glass panel, PC alloy enclosure + Precise temperature calibration function + Attractive appearance + Clear display, easy to operate + +Specification: + Power Supply:AC85-260V, 50/60HZ + Output: MH7H-WH ≤5A ; MH7H-EH≤ 16A + Self Consumption:≤1W + External Temp. Sensor(optional): NTC R25℃=15KΩ + B25℃/50℃=3550K + Working Environment:0-50℃; 0-90% RH(Non- + condensation) + Temperature Setting:5-37 ℃(41-99℉)(Adjustable) + Dimension:86* 86*15mm + Hole Pitch:60-61mm + + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2900/MH7H User Manual.pdf + In normal working interface, press & hold S4 to enter interface for adding or removing of Z-Wave network. Before device added into network, “- - -” will display on the screen. Then press S4 once, device will enter learning mode to get a node ID. If adding is succeed, a node ID will display on the screen in a few seconds. + +A node ID can always inform us whether the device is in the network or not. + +After adding, turn off the device and then turn it on. Now the device is ready to be operated by controller/ gateway in Z-Wave network. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2900/xml + + + + + + + + + + + + + + + + + + + + + + + 0 + true + + + + + + Upload temperature format automatically + + + + + + Upload temperature and humidity automatically + + + + + + + Base on 0.1C unit, 5 by default, 5*0.1C=0.5C + + + Base on 1s unit, it suggest to be set above 30s + + + Upload when percent difference exceeded + + + Restore the factory setting - write only, set to 85 to reset + + + + + + + + + + + diff --git a/openzwave/mcohome/mh8fceu.xml b/openzwave/mcohome/mh8fceu.xml new file mode 100644 index 00000000..67302e60 --- /dev/null +++ b/openzwave/mcohome/mh8fceu.xml @@ -0,0 +1,29 @@ + + + + + 0 + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/mcohome/mh8fceu0803.xml b/openzwave/mcohome/mh8fceu0803.xml new file mode 100755 index 00000000..b637d8b8 --- /dev/null +++ b/openzwave/mcohome/mh8fceu0803.xml @@ -0,0 +1,56 @@ + + + + MH8-FC + Fan Coil Thermostat MH8 is a Z-Wave Plus enabled device for indoor temperature control. + +It is mainly applied to a 2-pipe Fan coil system. + +It can read room temperature and local time, + +and automatically control fan speed based on the temperature difference. + +The device is of high reliability and practicability. + +This product can be included and operated + +in any Z-Wave network with other Z-Wave certified devices + +from any other manufacturers. + http://www.openzwave.com/device-database/015f:5102:0803 + http://www.mcohome.com/ProductDetail/3894174.html + http://www.mcohome.com/ProductDetail/3894174.html + images/mcohome/mh8fceu0803.png + http://www.mcohome.com/index.php?c=Front/DownDetail&a=downloadFujian&name=MH8-FC%20/%20MH8-FC4&path=L2NvbWRhdGEvOTUzMDEvcHJvZHVjdGZ1amlhbi8yMDIwMDYwMzE1MDQwNjVlZDc0YjY2MjRmODkucGRm + mh8fceu + + Initial Metadata Import + + + + + 0 + false + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/mcohome/mh9co2.xml b/openzwave/mcohome/mh9co2.xml new file mode 100644 index 00000000..c437d938 --- /dev/null +++ b/openzwave/mcohome/mh9co2.xml @@ -0,0 +1,29 @@ + + + + + + + CO2 Notification threshold 1 to 2000ppm + + + 0 report disabled, base on 5ppm unit, 10 by default, 10*5ppm=50ppm + + + 0 report disabled, base on 0.5C unit, 1 by default, 1*0.5C=0.5C + + + 0 report disabled, base on 1% unit, 2 by default, 2*1C=2C + + + Restore the factory setting - write only, set to 85 to reset + + + + + + + + + + diff --git a/openzwave/mcohome/mhp210.xml b/openzwave/mcohome/mhp210.xml new file mode 100644 index 00000000..de811a55 --- /dev/null +++ b/openzwave/mcohome/mhp210.xml @@ -0,0 +1,28 @@ + + + + + + + + Bit 0: KWH Report + Bit 1: Voltage Report + Bit 2: Current Report + Bit 3: Watt Report + (Bit Set to 1: enable 0:disable) + + + + 0 to 65535 second. + + + + + + + + + + + + diff --git a/openzwave/mcohome/mhp220.xml b/openzwave/mcohome/mhp220.xml new file mode 100644 index 00000000..cbbfa8d6 --- /dev/null +++ b/openzwave/mcohome/mhp220.xml @@ -0,0 +1,111 @@ + + + http://www.openzwave.com/device-database/015F:5101:220A + images/mcohome/mhp220.png + https://products.z-wavealliance.org/products/3011/ + MH-P220 + Restoring Factory Settings: +The default configuration can be restored by: +* Sending commands through controller/gateway (the command classes which support this function is Configuration Command Class). The parameter are as follows: + +Parameter Number 0xFF +Size 1 BYTE +Default value N/A +Configuration value 0x55 +Set 0xFF as 0x55 will restore Factory Settings. + +* Or press the inner button on the module 10 times in quick succession.Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3011/MH-P220UserManual.pdf + U.S. / Canada / Mexico + Remove the device from Z-Wave network: +1. Set controller into REMOVE mode. Follow the instructions provided by the controller/gateway manufacturer. +2. Press the momentary button on the device 3 times, or the connected external button S1 3 times in quick succession. +Note: If the REMOVE is successful, the INDICATION LED will blink 6 times. If not, INDICATION LED will be solid on or off depending on switch’s state. + + Micro Dimmer MHP-220 + This in-wall module is with compact design as well as stable performance, which can suit for any of the installation box and various operation situation. It supports basic command class, and also can act as repeater regardless of vendor to increase reliability of the network. + Add the device into Z-Wave network: +1. Set controller into ADD mode. Follow the instructions provided by the controller/gateway manufacturer. +2. Press the momentary button on the device 3 times, or the connected external button S1 3 times in quick succession. +Note: If the ADD is successful, the INDICATION LED will blink 6 times. If not, INDICATION LED will be solid on or off depending on switch’s state. + + + Initial Metadata Import from Z-Wave Alliance Database - file based on 1.4 version by @tonbor PR #1853 + + + + + + + Dimmer state saved or not when power down + + + External switch type + + + 2-state Switches + + + ALL ON/ALL OFF + + + Minimum brightness level + + + Maximum brightness level + + + Single dimming step time(Manual) + + + Single dimming step size (Manual) + + + Single dimming step time (Auto) + + + Single dimming step size (Auto) + + + Timer function (Auto-off) + + + One click of S1 + + + Double click of S1 + + + Operation report from Switch1 to Association Group 2 and 3 + + + Operation report from Switch1 to Association Group 2 + + + Switch 2 function + + + Operation report from Switch2 to Association Group 4 + + + Scene ID sent to AG1 when one click of S2 + + + Scene ID sent to AG1 when double click of S2 + + + Scene ID sent to AG1 when hold S2 + + + + + + + + + + + + + diff --git a/openzwave/mcohome/mhp511.xml b/openzwave/mcohome/mhp511.xml new file mode 100644 index 00000000..476ba6c8 --- /dev/null +++ b/openzwave/mcohome/mhp511.xml @@ -0,0 +1,151 @@ + + + + MH-P511 Touch Panel Dimmer Switch + MCOHome Touch Panel Dimmer Switch is a wall switch with built-in dimmer & Z-Wave module together in one compact unit. It supports basic command class,association command class, which can control all associated devices synchronously. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers. + http://www.openzwave.com/device-database/015f:1453:511a + http://www.mcohome.com/show_list.php?id=13&sid=47 + http://www.mcohome.com/show_list.php?id=17&pcate=13&mid=47 + images/mcohome/mhp511.png + https://smarthome.hancan.com.au/wp-content/uploads/2018/02/MH-P511_UM_V.02.pdf + Press the key on the panel 3 times in quick succession (within approx 1.5sec) + Press the key on the panel 3 times in quick succession (within approx 1.5sec) + Write 0x55 to Configuration Parameter Index 255 + Australia / New Zealand + MH-P511-AU + + Initial creation of config file from import of data from User Manual + + + + + + Dimmer state saved or not when power down + + + + + Beep + + + + + + LED Backlit brightness level. + 0 = Off; + 10 = Max brightness + + + + All On / All Off + + + + + + + Minimum brightness level (should be less than Maximum brightness level) + + + Maximum brightness level (should be greater than Minimum brightness level) + + + + Manual single dimming step time, in 10ms steps. + Manual control achieved by holding external button. + + + + + Manual single dimming step size. + Manual control achieved by holding external button. + Modification isn’t recommended! + + + + + Auto single dimming step time, in 10ms steps. + Auto control achieved by double click external button. + + + + + Auto single dimming step size. + Auto control achieved by double click external button. + Modification isn’t recommended! + + + + + Timer function (Auto-off). + 0 = function disabled + 1 - 255 = 1s - 255s auto-off delay + + + + + One click of external button (S1). + 0 = either (switch Off) or (switch On to last saved brightness level) + 1 - 99 = either (switch Off) or (switch On to set percentage brightness level) + + + + Double click of external button (S1) + + + + + + Operation report from external button (S1) to Association Group 2 & 3 + Device send Basic Set to AG2; Send Multilevel Set to AG3 + + + + + + + + + + Operation report from external button (S1) to Association Group 2 + + + + + + 0 = Scene Activation disabled + 1 - 255 = send Activation CC to AG1 with specified Scene ID + + + + + For momentary button only + 0 = Scene Activation disabled + 1 - 255 = send Activation CC to AG1 with specified Scene ID + + + + + For momentary button only + 0 = Scene Activation disabled + 1 - 255 = send Activation CC to AG1 with specified Scene ID + + + + Restore factory setting + + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/mcohome/mhs311.xml b/openzwave/mcohome/mhs311.xml new file mode 100644 index 00000000..7190f39b --- /dev/null +++ b/openzwave/mcohome/mhs311.xml @@ -0,0 +1,20 @@ + + + + + + + Switch state saved or not when power down + + + + + + + + + + + + + diff --git a/openzwave/mcohome/mhs312.xml b/openzwave/mcohome/mhs312.xml new file mode 100644 index 00000000..6561e7e7 --- /dev/null +++ b/openzwave/mcohome/mhs312.xml @@ -0,0 +1,25 @@ + + + + + + Switch state saved or not when power down + + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/mcohome/mhs314.xml b/openzwave/mcohome/mhs314.xml new file mode 100644 index 00000000..26705b25 --- /dev/null +++ b/openzwave/mcohome/mhs314.xml @@ -0,0 +1,33 @@ + + + + + + Switch state saved or not when power down + + + + + + + + true + + + + + + true + + + + + + + + + + + + + diff --git a/openzwave/mcohome/mhs411.xml b/openzwave/mcohome/mhs411.xml new file mode 100644 index 00000000..6ddc7e0e --- /dev/null +++ b/openzwave/mcohome/mhs411.xml @@ -0,0 +1,20 @@ + + + + + + + Switch state saved or not when power down + + + + + + + + + + + + + diff --git a/openzwave/mcohome/mhs412.xml b/openzwave/mcohome/mhs412.xml new file mode 100644 index 00000000..8da6f100 --- /dev/null +++ b/openzwave/mcohome/mhs412.xml @@ -0,0 +1,25 @@ + + + + + + Switch state saved or not when power down + + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/mcohome/mhs513.xml b/openzwave/mcohome/mhs513.xml new file mode 100644 index 00000000..cad9d940 --- /dev/null +++ b/openzwave/mcohome/mhs513.xml @@ -0,0 +1,26 @@ + + + + + + Switch state saved or not when power down + + + + + + + + true + + + + + + + + + + + + diff --git a/openzwave/merten/5044xx.xml b/openzwave/merten/5044xx.xml new file mode 100644 index 00000000..eb9399c0 --- /dev/null +++ b/openzwave/merten/5044xx.xml @@ -0,0 +1,24 @@ + + + http://www.openzwave.com/device-database/007A:0001:4002 + images/merten/5044xx.png + https://products.z-wavealliance.org/products/321/ + CEPT (Europe) + 5044xx + 5044xx - Radio sensor cover for in-wall switch + http://www.merten.com/Radio-transmitter-and-radio-receiver.148.0.html?&L=3%3Fq%3Dplus%20lin + http://www.merten.com/Info-Centre.59.0.html + Binary Switch + Sensor Plate.CONNECT radio push-button, 1-gang + +To control the radio receiver + +Extremely flat design +The ideal solution for retrofitting +Can be secured with screws or adhesive +Can be snapped into existing switch ranges + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/321/xml + + + + diff --git a/openzwave/merten/5046xx.xml b/openzwave/merten/5046xx.xml new file mode 100644 index 00000000..b63298ee --- /dev/null +++ b/openzwave/merten/5046xx.xml @@ -0,0 +1,15 @@ + + + http://www.openzwave.com/device-database/007A:0001:4003 + images/merten/5046xx.png + https://products.z-wavealliance.org/products/494/ + CEPT (Europe) + Radio sensor cover for in wall dimmer + 5046xx - Radio sensor cover for in wall dimmer + 5046xx + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/494/xml + + + + diff --git a/openzwave/merten/506004.xml b/openzwave/merten/506004.xml new file mode 100644 index 00000000..9e814336 --- /dev/null +++ b/openzwave/merten/506004.xml @@ -0,0 +1,21 @@ + + + http://www.openzwave.com/device-database/007A:0004:0003 + images/merten/506004.png + https://products.z-wavealliance.org/products/211/ + CEPT (Europe) + http://www.merten.com/Radio-transmitter-and-radio-receiver.148.0.html?&L=3%3Fq%3Dplus%20lin + 506004 4-Channel Binary Sensor.CONNECT radio transmitter flush-mounted, 4-gang + +For integration into any conventional switch range in the radio system + +Just place the radio pellet behind the push-button or switch inserts in the flush-mounted socket + + http://www.merten.com/Info-Centre.59.0.html + 506004 Radio Transmitter flush-mounted CONNECT, 4-gang + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/211/xml + + + + diff --git a/openzwave/merten/507801.xml b/openzwave/merten/507801.xml new file mode 100644 index 00000000..579be1df --- /dev/null +++ b/openzwave/merten/507801.xml @@ -0,0 +1,32 @@ + + + + + To configure the time (value * 0.1 sec) the motor waits before switching direction. + + + To configure input 1 of the raising time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + To configure input 1 of the raising time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + To configure input 1 of the lowering time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + To configure input 1 of the lowering time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + + + + false + + + + + + + + + diff --git a/openzwave/merten/508244.xml b/openzwave/merten/508244.xml new file mode 100644 index 00000000..31f2e0d3 --- /dev/null +++ b/openzwave/merten/508244.xml @@ -0,0 +1,21 @@ + + + http://www.openzwave.com/device-database/007A:0001:0002 + images/merten/508244.png + https://products.z-wavealliance.org/products/268/ + Battery powered pushbutton devices that controls other devices. + +(1 Key Device) (5080xx)Move - Mobile switching and dimming of lighting + +Move is for anyone who wants to be even more fl exible. The new little round radio push-button can be easily removed from its respective wall bracket and used as a radio remote control. And you can snap it back into the frame when you're done. + 508244 - CONNECT MOVE + http://www.merten.com/Info-Centre.59.0.html + CEPT (Europe) + http://www.merten.com/Radio-transmitter-and-radio-receiver.148.0.html?&L=3%3Fq%3Dplus%20lin + 508244 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/268/xml + + + + diff --git a/openzwave/merten/50x5xx.xml b/openzwave/merten/50x5xx.xml new file mode 100644 index 00000000..d1ed7d67 --- /dev/null +++ b/openzwave/merten/50x5xx.xml @@ -0,0 +1,56 @@ + + + + + To configure if other radio receivers from Merten should be switched as well. + + + To configure the time the motor waits before switching direction. + + + To configure input 1 of the raising time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + To configure input 1 of the raising time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + To configure input 1 of the lowering time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + To configure input 1 of the lowering time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + To configure use of light sensor. Default: 0 . + + + + + + To configure brightness threshold for light sensor. + + + To configure input 1 of reaction threshold for raising shutter time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + To configure input 2 of reaction threshold for raising shutter time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + To configure input 1 of reaction threshold for lowering shutter time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + To configure input 2 of reaction threshold for lowering shutter time calculation (256 * Input 1 + Input 2) * 0.1 sec + + + + + + false + + + + + + + + + diff --git a/openzwave/miyakawaelectric/me-d101.xml b/openzwave/miyakawaelectric/me-d101.xml new file mode 100644 index 00000000..49495d43 --- /dev/null +++ b/openzwave/miyakawaelectric/me-d101.xml @@ -0,0 +1,15 @@ + + + http://www.openzwave.com/device-database/0122:0001:0001 + images/miyakawaelectric/me-d101.png + https://products.z-wavealliance.org/products/633/ + Japan + ME-D101 + Electric power measuring instrument for the home + MSK CT type electric power measuring instrument + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/633/xml + + + + diff --git a/openzwave/namron/1402756.xml b/openzwave/namron/1402756.xml new file mode 100644 index 00000000..551d38e1 --- /dev/null +++ b/openzwave/namron/1402756.xml @@ -0,0 +1,84 @@ + + + + + Namron LED Dimmer Z-Wave 200W + LED Z-Wave dimmer with smart functionality and power consumption tackle most conditions such as LED, halogen or electronic transformer. Possibility of wireless control via central unit / gateway or pulse control by direct connection. +Technical description + +A trailing edge dimmer, for use with 230V Halogen, 230V LED and electronic transformers. Has built-in short cut protection in case of lamp failure. Only need L-conductor connected. + images/namron/1402756.png + Double click on the reset button + Double click on the reset button + Hold reset button for >5 secs + 1402756 + + Handcrafted based on domoticz/Config/config-template.xml and Vendors product manual + Add Product Pic + + + + + + + + Saving state before power failure. + Default Not saved. + + + + + + + Enable/disable to send notification to the Group Lifeline when the load state changed. + When value set as 1, re-power on the dimmer, it will send Basic report automatically. + Default Enabled. + + + + + + Dimming speed in seconds. Valid values is 0-100. + Default 5. + + + + + Enable or Disable external switch to pair network + + + + + + + Set the Dimming mode to be Linear or Logaritmic + + + + + + Setting brightness when turn on dimmer from off status. + Setting of 0 means that the dimmer will use parameter 1. + Valid values: 0-99 + + + + + Setting delay time in seconds when load is turned off. + Valid values : 0-60 seconds + + + + + + + + + + + + + diff --git a/openzwave/nexia/db100z.xml b/openzwave/nexia/db100z.xml new file mode 100644 index 00000000..e1f03a46 --- /dev/null +++ b/openzwave/nexia/db100z.xml @@ -0,0 +1,46 @@ + + + http://www.openzwave.com/device-database/0178:3130:4442 + images/nexia/db100z.png + https://products.z-wavealliance.org/products/1349/ + When the Install Button is triple-pressed, the device will send a Wakeup Notification report and stay awake for 10 seconds. + +WAKEUP_INTERVAL_CAPABILITIES_REPORT +Min Wake Up Interval :60 seconds +Max Wake Up Interval: 86400 seconds +Default Wake Up Interval: 25200 seconds +Wake Up Interval Step: 60 + + 1. Set primary controller to Exclude mode +2. Press the Install Button + Z-Wave Doorbell Sensor + The DB100Z is a battery powered, voltage sensing device that sends out a Notification report when voltage is detected at the sensor inputs. + 1. Set primary controller to Include mode +2. Press the Install Button + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1349/18-HD77D1-1-EN DB100Z Z-Wave Door Bell Sensor.pdf + DB100Z + U.S. / Canada / Mexico + Please only perform a factory reset when the primary controller is missing or inoperable. A factory reset will remove all network settings and configurations. + +1. Hold down Install Button for 10 seconds +2. Release the Install Button +3. When the Status LED begins to blink, the unit has finished restoring configuration + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1349/xml + + + + + + Send a battery report in addition to the alarm report when the alarm report is triggered + + + + + + + + + + + diff --git a/openzwave/nexia/th100nx.xml b/openzwave/nexia/th100nx.xml new file mode 100644 index 00000000..06df0367 --- /dev/null +++ b/openzwave/nexia/th100nx.xml @@ -0,0 +1,98 @@ + + + + Remote Temperature and Humidity Sensor + The Remote Temperature and Humidity sensor is a Z-Wave Plus multilevel, battery-powered, routing sensor that measures and reports indoor temperature and relative humidity. The reporting intervals and thresholds for the indoor temperature, indoor humidity and battery are configurable. The wakeup interval is also configurable. This sensor cannot be used with Trane/American Standard thermostats for HVAC control. + http://www.openzwave.com/device-database/0178:3130:5448 + https://products.z-wavealliance.org/products/2223 + images/nexia/th100nx.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2223/18-HD84D1-1A.pdf + Press the Install button three times rapidly to send a Battery Report and Wakeup Notification when installed on a network. + Set primary controller to inclusion mode, then press and release install button. Status LED will blink three times to show success. + Set primary controller to exclusion mode, then press and release install button. Status LED will blink three times to show success. + Press and hold install button for 10 seconds to restore to factory defaults. + https://products.z-wavealliance.org/products/2223 + U.S. / Canada / Mexico + TH100NX + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2223/xml + + + + + + Time between Battery Reports in hours + + + + BASIC SET ON above this temperature. + + + + BASIC SET ON below this temperature. + + + + BASIC SET OFF above this temperature. + + + + BASIC SET OFF below this temperature. + + + + How many attempts + + + + Temperature Units used + + + + + BASIC SET ON above this humidity + + + + BASIC SET ON below this humidity + + + + BASIC SET OFF above this humidity + + + + BASIC SET OFF below this humidity + + + + Basic Set Options for temperature and humidity. + 1 = Enable Registers 2, 5, 12 15 + 2 = Enable Registers 2, 5, 13, 14 + 3 = Enable Registers 3, 4, 12, 15 + 4 = Enable Registers 3, 4, 13, 14 + + + + Temperature offset + + + Humidity offset + + + BASIC SET ON above this humidity + + + + + + + + + + + + + + diff --git a/openzwave/nodon/asp3100SmartPlug.xml b/openzwave/nodon/asp3100SmartPlug.xml new file mode 100644 index 00000000..bcc5d1b6 --- /dev/null +++ b/openzwave/nodon/asp3100SmartPlug.xml @@ -0,0 +1,124 @@ + + + http://www.openzwave.com/device-database/0165:0001:0001 + images/nodon/asp3100SmartPlug.png + https://products.z-wavealliance.org/products/1069/ + Long press during 2 seconds to send several NIF during 30 seconds or a triple press to send a single NIF + Long press during 2 seconds to send several NIF during 30 seconds or a triple press to send a single NIF + CEPT (Europe) + The NodOn Smart Plug can be controlled by any kind of Z-Wave® (or Z-Wave Plus®) gateway or other Z-Wave® controller (standalone mode) such as the NodOn® Soft Remote or Octan Remote. +In both standard, Type E (French) or Schuko (German), the plug can be mounted in both side (head up or head down). Combined to its ultra-thin design, these both specificities allow an easy integration, without obstructing nearby power holes on a power strip. +Equipped with a very small super-capacitor, the NodOn Smart Plug is able to send an emergency frame to the gateway in case of power outage. + +The NodOn Smart Plug is based on brand new 500 series Z-Wave® module from Sigma Designs®, and support all the new features of Z-Wave Plus® standard: +Longer range (up to 40m), lower power consumption, higher data rate transmission, and many more new features. + Long press during more than 5 seconds then release. +Please use this procedure only when the primary controller is missing or otherwise inoperable. + Z-Wave+ Smart Plug ON/OFF (Type E) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1069/NodOn_SmartPlug_ZWave_UserGuide_EN.pdf + ASP-3-1-00 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1069/xml + + + + + + + After Power-On-Reset of the device, the Channel Output State is set in Default State + + + + + + + This parameter allows unsolicited Notification Report Commands and/or Basic Set Commands to be sent when a power failure detection and/or a power failure recover occurs. Only the four least significant bits can be addressed. + + Bit 0: Enable or disable power failure detection and recover. Setting this bit to 1 automatically allows the product to send unsolicited report through Lifeline. If this bit is not set, it is not possible to enable Association Group 4, 5 and 6. Consequently, if a Configuration Set Command is received, enabling one or more Association Groups (4, 5 and / or 6), this bit will be automatically set. + Bit 1: Enable or disable unsolicited Notification Report: Power Management - AC disconnected Command and Notification Report: Power Management - AC re-connected Command sent to associated nodes of Group 4, when, respectively, power failure is detected or power failure is recovered. + Bit 2: Enable or disable Basic Set ON Command sent to associated nodes of Group 5, when power failure is detected. + Bit 3: Enable or disable Basic Set OFF Command sent to associated nodes of Group 6, when power failure is detected. + Bit 4: Enable or disable Basic Set ON Command sent to associated nodes of Group 7, when power recover is detected. + Bit 5: Enable or disable Basic Set OFF Command sent to associated nodes of Group 8, when power recover is detected. + + + + + This parameter allows Basic Set Commands to be sent when the channel output state changes (ON or OFF). Only the two least significant bits can be addressed. + Bit 0: Enable or disable Basic Set Commands sent to associated nodes of Group 2, when Channel Output State changes. + Bit 1: Enable or disable Basic Set Commands sent to associated nodes of Group 3, when Channel Output State changes. + + + + This parameter forces the channel output state to be always ON. It is not possible to turn OFF the channel output, which means that: + * All Switch OFF Command is rejected + * Basic Set OFF Command is rejected + * Binary Switch OFF Command is rejected + * Local Control does not toggle channel output state + * Product cannot be triggered by unsolicited Notification Report Command and enters in Alarm Mode + + + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + see Appendix C - Description of Alarm Parameters + + + + + + + + + + + + + + + + diff --git a/openzwave/nodon/crc3100OctanRemote.xml b/openzwave/nodon/crc3100OctanRemote.xml new file mode 100644 index 00000000..4dc3129c --- /dev/null +++ b/openzwave/nodon/crc3100OctanRemote.xml @@ -0,0 +1,120 @@ + + + http://www.openzwave.com/device-database/0165:0001:0002 + images/nodon/crc3100OctanRemote.png + https://products.z-wavealliance.org/products/1923/ + Simultaneously push on buttons 3 and 4, during 1 second. The LED will blink red and green to validate the factory reset. + +A factory reset will completely delete the memory of the remote control and restore all parameters to default value. +In "Standalone" Mode, make sure to remove all the devices added or associated in the remote control's network before performing a factory reset. +In "Gateway" Mode, use the factory reset procedure only when the primary controller (i.e the Gateway) is missing or defective. Reset the remote control does not mean that it has been removed from the primary controller memory. Remove the remote control (through the primary controller) before performing a factory reset. + CEPT (Europe) / U.S. / Canada / Mexico + OCTAN Remote + CRC-3-1-0X + The OCTAN Remote NodOn® controls any compatible receivers Z-Wave® or Z-Wave Plus®, such as the Smart Plug NodOn®. It can address, directly, up to 4 groups of 8 devices and sent up to 16 different scenes to a Home Automation Gateway. This controller can operate on its own (“Standalone” Mode) or as gateway’s assistant (“Gateway” Mode). The product integrates a LED, which give an intuitive feedback for each operation you perform. + +Based on an innovative technology, the OCTAN Remote NodOn® is only powered with a CR2032 battery, offering 2 years’ autonomy. + +A magnetic wall support is included with your OCTAN Remote NodOn®, which allow you to easily install and move it. This support can be screwed or fixed by adhesive bonding. The remote control embeds a small magnet, allowing fixing it on its wall support or on any metallic surface (fridge door, heater, etc.). + +The OCTAN Remote NodOn® is based on brand new 500 series Z-Wave® module from Sigma Designs®, and supports all the new features of Z-Wave Plus® standard: +Longer range (up to 40 meters indoor), lower power consumption, higher data rate transmission, and many more new features. + + When the product in "Gateway" mode, any action on button will send a wake up notification to the gateway. + 1- Push 3 times (quickly) on the button 4. The LED blinks in blue. + +2- Place the device you want to remove in "Learning" Mode, within 10 seconds. To do so, please refer to your device's user guide. + +3- The LED blinks in green to confirm the exclusion. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1923/NodOn-CRC-3-1-xx-UserGuide-150528-EN-online.pdf + 1- Push 3 times (quickly) on the button 1. The LED blinks in blue. + +2- Place the device you want to add in "Learning" Mode, within 10 seconds. To do so, please refer to your device's user guide. + +3- The LED blinks in green to confirm the inclusion. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1326/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1923/xml + + + + + + + This parameter configures the behavior of the buttons 1 and 3 when the product is in "Gateway Centric Mode" + + + + + + This parameter configures the behavior of the buttons 2 and 4 when the product is in "Gateway Centric Mode" + + + + + + This parameter configures the type of command sent when the product is in "Gateway Centric Mode", with buttons profile configuration set in "Scene Behavior". + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/nodon/crc360xSofremote.xml b/openzwave/nodon/crc360xSofremote.xml new file mode 100644 index 00000000..b3e8d112 --- /dev/null +++ b/openzwave/nodon/crc360xSofremote.xml @@ -0,0 +1,117 @@ + + + http://www.openzwave.com/device-database/0165:0002:0002 + images/nodon/crc360xSofremote.png + https://products.z-wavealliance.org/products/1924/ + Simultaneously push on buttons 3 and 4, during 1 second. The LED will blink red and green to validate the factory reset. + +A factory reset will completely delete the memory of the Soft Remote and restore all parameters to default value. +In "Standalone" Mode, make sure to remove all the devices added or associated in the Soft Remote's network before performing a factory reset. +In "Gateway" Mode, use the factory reset procedure only when the primary controller (i.e the Gateway) is missing or defective. Reset the Soft Remote does not mean that it has been removed from the primary controller memory. Remove the Soft Remote (through the primary controller) before performing a factory reset. + CRC-3-6-0X + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1924/NodOn-CRC-3-6-xx-UserGuide-160816-EN-interactive.pdf + When the product in "Gateway" mode, any action on button will send a wake up notification to the gateway. + CEPT (Europe) / U.S. / Canada / Mexico + 1- Push 3 times (quickly) on the button 4. The LED blinks in blue. + +2- Place the device you want to remove in "Learning" Mode, within 10 seconds. To do so, please refer to your device's user guide. + +3- The LED blinks in green to confirm the exclusion. + + NodOn® Soft Remote + 1- Push 3 times (quickly) on the button 1. The LED blinks in blue. + +2- Place the device you want to add in "Learning" Mode, within 10 seconds. To do so, please refer to your device's user guide. + +3- The LED blinks in green to confirm the inclusion. + The NodOn® Soft Remote controls any compatible receivers Z-Wave® or Z-Wave Plus®, such as the Smart Plug NodOn®. It can address, directly, up to 4 groups of 8 devices and sent up to 16 different scenes to a Home Automation Gateway. This controller can operate on its own (“Standalone” Mode) or as gateway’s assistant (“Gateway” Mode). The product integrates a LED, which give an intuitive feedback for each operation you perform. + +Based on an innovative technology, the NodOn® Soft Remote is only powered with a CR2032 battery, offering 2 years’ autonomy. + +The NodOn® Soft Remote is based on brand new 500 series Z-Wave® module from Sigma Designs®, and supports all the new features of Z-Wave Plus® standard: +Longer range (up to 40 meters indoor), lower power consumption, higher data rate transmission, and many more new features. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1418/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1924/xml + + + + + + + This parameter configures the behavior of the buttons 1 and 3 when the product is in "Gateway Centric Mode" + + + + + + This parameter configures the behavior of the buttons 2 and 4 when the product is in "Gateway Centric Mode" + + + + + + This parameter configures the type of command sent when the product is in "Gateway Centric Mode", with buttons profile configuration set in "Scene Behavior". + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/nodon/cws3101wallswitch.xml b/openzwave/nodon/cws3101wallswitch.xml new file mode 100644 index 00000000..76138f12 --- /dev/null +++ b/openzwave/nodon/cws3101wallswitch.xml @@ -0,0 +1,117 @@ + + + http://www.openzwave.com/device-database/0165:0003:0002 + images/nodon/cws3101wallswitch.png + https://products.z-wavealliance.org/products/1383/ + NodOn® wall switch + When the product in "Gateway" mode, any action on button will send a wake up notification to the gateway. + Simultaneously push on buttons 3 and 4, during 1 second. The LED will blink red and green to validate the factory reset. + +A factory reset will completely delete the memory of the wall switch and restore all parameters to default value. +In "Standalone" Mode, make sure to remove all the devices added or associated in the wall switch's network before performing a factory reset. +In "Gateway" Mode, use the factory reset procedure only when the primary controller (i.e the Gateway) is missing or defective. Reset the wall switch does not mean that it has been removed from the primary controller memory. Remove the wall switch (through the primary controller) before performing a factory reset. + The NodOn® wall switch controls any compatible receivers Z-Wave® or Z-Wave Plus®, such as the Smart Plug NodOn®. It can address, directly, up to 4 groups of 8 devices and sent up to 16 different scenes to a Home Automation Gateway. This controller can operate on its own (“Standalone” Mode) or as gateway’s assistant (“Gateway” Mode). The product integrates a LED, which give an intuitive feedback for each operation you perform. + +Based on an innovative technology, the NodOn® wall switch is only powered with a CR2032 battery, offering 2 years’ autonomy. + +The NodOn® wall switch can be screwed or bonded thanks of the +adhesive tape included. + +The NodOn® wall switch is based on brand new 500 series Z-Wave® module from Sigma Designs®, and supports all the new features of Z-Wave Plus® standard: +Longer range (up to 40 meters indoor), lower power consumption, higher data rate transmission, and many more new features. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1383/CWS-3-1-xx-certicfication-product-150701.pdf + CWS-3-1-0X + 1- Push 3 times (quickly) on the button 2. The LED blinks in blue. + +2- Place the device you want to remove in “Learning” Mode. To do so, please refer to your device’s user guide. The LED blinks in green to confirm the exclusion. + + CEPT (Europe) + 1- Push 3 times (quickly) on the button 3. The LED blinks in blue. + +2- Place the device you want to add in “Learning” Mode. To do so, please refer to your device’s user guide. The LED blinks in green to confirm the inclusion. + +Note: If you wish to include and associate a device, please refer to "Other Special Features" + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1383/xml + + + + + + + This parameter configures the behavior of the buttons 1 and 3 when the product is in "Gateway Centric Mode" + + + + + + This parameter configures the behavior of the buttons 2 and 4 when the product is in "Gateway Centric Mode" + + + + + + This parameter configures the type of command sent when the product is in "Gateway Centric Mode", with buttons profile configuration set in "Scene Behavior". + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + When button are set in Mono Button mode they can have 3 different behaviors : + 1: They can directly control other nodes with Basic and multi-level command class + 2: Send Switch All On command + 3: Send Switch All Off command + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/nodon/msp31xxMicroSmartPlug.xml b/openzwave/nodon/msp31xxMicroSmartPlug.xml new file mode 100644 index 00000000..90227f60 --- /dev/null +++ b/openzwave/nodon/msp31xxMicroSmartPlug.xml @@ -0,0 +1,129 @@ + + + http://www.openzwave.com/device-database/0165:0003:0001 + images/nodon/msp31xxMicroSmartPlug.png + https://products.z-wavealliance.org/products/1701/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1701/NodOn-MSP-3-1-xx-UserGuide-160314-EN-interactive.pdf + To reset, long press during more than 5 seconds then release. +Please use this procedure only when the primary controller is missing or otherwise inoperable. + To include/add to the Z-Wave network, long press during 2 seconds to send several NIF during 30 seconds or a triple press to send a single NIF + Z-Wave Plus Micro Smart Plug ON/OFF + To exclude/remove from the Z-Wave network, long press during 2 seconds to send several NIF during 30 seconds or a triple press to send a single NIF + The NodOn Micro Smart Plug can be controlled by any kind of Z-Wave® (or Z-Wave Plus®) gateway or other Z-Wave® controller (standalone mode) such as the NodOn® Soft Remote or Octan Remote. +It existed in both standard, Type E (French) or Schuko (German). Its very small design and volume allow easy integration, without obstructing nearby power holes on a power strip. Furthermore, it can perform Power and Energy Metering. +The NodOn Smart Plug is based on brand new 500 series Z-Wave® module from Sigma Designs®, and support all the new features of Z-Wave Plus® standard: +Longer range (up to 40m), lower power consumption, higher data rate transmission, and many more new features. + MSP-3-1-X1 + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1701/xml + + + + + + + After Power-On-Reset of the device, the Channel Output State is set in Default State + + + + + + + This parameter allows Basic Set Commands to be sent when the channel output state changes (ON or OFF). Only the two least significant bits can be addressed. + Bit 0: Enable or disable Basic Set Commands sent to associated nodes of Group 2, when Channel Output State changes. + Bit 1: Enable or disable Basic Set Commands sent to associated nodes of Group 3, when Channel Output State changes. + + + + This parameter forces the channel output state to be always ON. It is not possible to turn OFF the channel output, which means that: + * All Switch OFF Command is rejected + * Basic Set OFF Command is rejected + * Binary Switch OFF Command is rejected + * Local Control does not toggle channel output state + * Product cannot be triggered by unsolicited Notification Report Command and enters in Alarm Mode + + + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + Go to www.nodon.fr/support/msp3/alarm to configure alarm + + + 0 is disabled. 1-100 sends report on x% variation + + + 0 is disabled. 1-4000 sends report on x W overload + + + 0 is disabled. 1-65535 sends report every x seconds + + + 0 is disabled. 1-65535 sends report every x seconds + + + 0 is disabled. 1-65535 x W + + + 0 is disabled. 1-65535 x W + + + 0 disbaled. 1 Send Off to group 4. 3 Send On to group 4. 4 Send Off to group 5. 12 Send On to group 5. Values can be summed + + + + + + + + + + + + + + diff --git a/openzwave/northq/nq9021.xml b/openzwave/northq/nq9021.xml new file mode 100644 index 00000000..4b69b2be --- /dev/null +++ b/openzwave/northq/nq9021.xml @@ -0,0 +1,73 @@ + + + + + + false + + + + + + How many pulses are counted per 10 kWh. + + + Defines the meter type on which the Power Reader is placed + + + + + + Additional time for feedback measurement. + Should always be 0. + + + + + Adjusts transmit signal so received signal will in average be equal to this values. + Auto calibration might select another value than this. + + + + + Wake device up this many times per second. + This value also controls number of measurements per second on mechanical meters. + + + + Low detection threshold for wheel meters. + + + High detection threshold for wheel meters. + + + Do not use. Set this value using WAKE_UP_INTERVAL_SET instead. + + + In order for the Power Reader to report the proper total meter consumption the value for this registered has to be initialized with total_meter_consumption_stated_on_the_meter * impulse factor. + + + set to the number of seconds that it will take the controlling node to send a response / request to the wake up notification + + + Set this to enter real-time mode from remote. Contains seconds * poll frequency before going back to sleep. If you press the button once this value will be set. + + + The serial numbers written on the Power Reader are in HEX + + + Debug Mode + + + + + The calibration progress is calculated as (value[1] - 65 + value[2] / value[3]) * 25 + The calibration is finished successfully when value[0] = 2 and value[2] = value[3]. + The calibration has failed if value[0] != 1 OR (value[0] = 2 AND value[2] != value[3]) + + + + diff --git a/openzwave/northq/nq9121.xml b/openzwave/northq/nq9121.xml new file mode 100644 index 00000000..915043f3 --- /dev/null +++ b/openzwave/northq/nq9121.xml @@ -0,0 +1,63 @@ + + + + + + false + + + + + + set the meter impulse or rotation factor x 10. + + + Defines the meter type on which the Power Reader is placed + + + + + + Additional time for feedback measurement. + Should always be 0. + + + + + Adjusts transmit signal so received signal will in average be equal to this values. + Auto calibration might select another value than this. + + + + + Wake device up this many times per second. + This value also controls number of measurements per second on mechanical meters. + + + + In order for the Power Reader to report the proper total meter consumption the value for this registered has to be initialized with total_meter_consumption_stated_on_the_meter * impulse factor. + + + set to the number of seconds that it will take the controlling node to send a response / request to the wake up notification + + + Set this to enter real-time mode from remote. Contains seconds * poll frequency before going back to sleep. If you press the button once this value will be set. + + + The serial numbers written on the Power Reader are in HEX + + + Debug Mode + + + + + The calibration progress is calculated as (value[1] - 65 + value[2] / value[3]) * 25 + The calibration is finished successfully when value[0] = 2 and value[2] = value[3]. + The calibration has failed if value[0] != 1 OR (value[0] = 2 AND value[2] != value[3]) + + + diff --git a/openzwave/northq/nq92021.xml b/openzwave/northq/nq92021.xml new file mode 100644 index 00000000..1c38c5de --- /dev/null +++ b/openzwave/northq/nq92021.xml @@ -0,0 +1,56 @@ + + + http://www.openzwave.com/device-database/0096:0001:0001 + images/northq/nq92021.png + https://products.z-wavealliance.org/products/69/ + http://northq.com/qpower/ + NorthQ has developed a small Power Reader that can be easily installed on existing electronic or mechanical meters in order to visualize electricity consumption in private homes. The meter reading solution is based on the Z-Wave wireless standard, which is ideal for controlling automation products within the home. + +The product consists of 3 parts: a Power Reader, a battery-powered wireless transmitter and a USB receiver. Electricity data is transferred to a chosen PC every 15 minutes, where it can then be visualized in the form of graphs, enabling customers to keep track of their electricity consumption (in kWh and in local currency), and monitor their CO2 emissions, etc. It is also possible to receive real-time measurements in order to investigate how much each individual appliance uses in active or standby mode. + +Furthermore, it is possible to enter a budget for how much you want to consume in EUR or kWh per year. The NorthQ eGadget on the screen continuously monitors and updates the electricity consumption data to indicate whether you are under or over budget. You are then able to compare your electricity consumption in the current year with that in previous years. It is also possible to compare the consumption in your current home with other types of homes, e.g. apartments, houses, villas, etc. + + CEPT (Europe) + NorthQ Power Reader & Power Manager + NQ-92021 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/69/xml + + + + + + How many pulses are counted per 10 kWh. + + + Defines the meter type on which the Power Reader is placed + + + + + Additional time for feedback measurement.Should always be 0. + + + Adjusts transmit signal so received signal will in average be equal to this values. Auto calibration might select another value than this. + + + Wake device up this many times per second. This value also controls number of measurements per second on mechanical meters. + + + Do not use. Set this value using WAKE_UP_INTERVAL_SET instead. + + + Current pulse count in device (pulse count / pulse factor = kWh). + + + set to the number of seconds that it will take the controlling node to send a response / request to the wake up notification + + + Set this to enter real-time mode from remote. Contains seconds * poll frequency before going back to sleep. If you press the button once this value will be set. + + + diff --git a/openzwave/oomi/ft100.xml b/openzwave/oomi/ft100.xml new file mode 100644 index 00000000..eb2dfc27 --- /dev/null +++ b/openzwave/oomi/ft100.xml @@ -0,0 +1,388 @@ + + + http://www.openzwave.com/device-database/016A:0064:0102 + images/oomi/ft100.png + https://products.z-wavealliance.org/products/1534/ + Oomi MultiSensor looks like a motion sensor and it acts like one too. But it’s also so much more. Installing this 1 piece of Z-Wave® technology is the same as installing 6 pieces of Z-Wave technology. Your home control network will immediately understand motion, temperature, humidity, light, Ultraviolet and Vibration readings wherever MultiSensor installed. Those intelligent readings will equate to intelligence automation. And intelligent automation will give you the perfect, smart home. + Pressing the Z-Wave button once will trigger sending the Wake up notification command. If press and hold the Z-Wave button for 3 seconds, the MultiSensor will wake up for 10 minutes. + U.S. / Canada / Mexico + FT100-A + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Z-Wave button that you can find in back of the product. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2592/Oomi MultiSensor manual3.pdf + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Z-Wave button that you can find in the back of the product. + Press and hold the Z-Wave button that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + MultiSensor + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1534/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2592/xml + + https://products.z-wavealliance.org/products/2592/ + China + FT100-K + + + + + + Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor + + + + + Duration that the motion sensor must observe no motion before it will return to the no-motion state. + If value greater than 255, effective value is rounded up to the nearest minute (255 -> 255 seconds, 256 -> 300 seconds) + + + Enable Motion Sensor, (1 minimum, 5 maximum sensitivity level) + + + + + + + + + Which commands to send when PIR motion sensor triggered + OZW Ideal Value is Binary Sensor Report + + + + + + Set the timeout of awake after the Wake Up CC is sent out. + Available rang: 8 to 255 seconds. + + + + Report the current power mode and the product state for battery power mode + + + + + + + Configure low battery value + Value=10 to 50. + + + Enable/disable the selective reporting only when measurements reach a certain threshold or percentage + set in the threshold settings. This is used to reduce network + traffic. + + + + + Threshold change in temperature to induce an automatic report. + Note: + 1. The unit is Fahrenheit for US version, Celsius for EU/AU version. + 2. The value contains one decimal point. E.g. if the value is set to 20, the threshold value = 2.0 C (EU/AU) or 2.0 F (US). When the temperature has changed by 2.0 (of the appropriate unit), a temperature report will be sent. + + + + Threshold change in humidity to induce an automatic report. + Note: + 1. The unit is %. + 2. The default value is 10, which means that a 10% change in humidity will trigger a report. + + + + Threshold change in luminance to induce an automatic report. + + + Threshold change in battery level to induce an automatic report. + Note: + 1. The unit is %. + 2. The default value is 10, which means that a 10% change in battery will trigger a report. + + + + Threshold change in ultraviolet to induce an automatic report. + + + + Enable/disable to send the alarm report of low temperature(Less than 15 Degress C) + + + + + + + Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. + Bit mask = 0, disable. + Bit mask = 1, enable. + Bit 0 = temperature. + Bit 1 = humidity. + Bit 2 = luminance. + Bit 3 = ultraviolet. + The above bit masks are used to enable/disable to send out a report when the measurement is less than the lower limit value. + The below bit masks are used to enable/disable to send out a report when the measurement is more than the upper limit value. + Bit 4 = temperature. + Bit 5 = humidity. + Bit 6 = luminance. + Bit 7 = ultraviolet. + Note: + If USB power, the Sensor will check the limit every 10 seconds. If battery power, the Sensor will check the limit when it is waken up. + + + + + When the measurement is more than this upper limit, which will trigger to sent out a sensor report. + High byte is the upper limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). + 1. When unit is Celsius. + Upper limit range: -40.0 to 100.0 C (0xFE70 to 0x03E8). + E.g. The default upper limit of EU/AU version is 28.0 C (0x0118), when the measurement is more than 28.0C, it will be triggered to send out a temperature sensor report. + 2. When unit is Fahrenheit. + Upper limit range: -40.0 to 212.0 F (0xFE70 to 0x0848). + E.g. The default upper limit of US version is 82.4F (0X0338), when the measurement is more than 82.4F, it will be triggered to send out a temperature sensor report. + + + + + When the measurement is less than this lower limit, which will trigger to sent out a sensor report. + High byte is the lower limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). + 1. When unit is Celsius. + Lower limit range: -40.0 to 100.0 C (0xFE70 to 0x03E8). + E.g. The default lower limit of EU/AU version is 0 C (0x0000), when the measurement is less than 0C, it will be triggered to send out a temperature sensor report. + 2. When unit is Fahrenheit. + Upper limit range: -40.0 to 212.0 F (0xFE70 to 0x0848). + E.g. The default lower limit of US version is 32.0F (0x0140), when the measurement is less than 32.0F, it will be triggered to send out a temperature sensor report. + + + + + When the measurement is more than this upper limit, which will trigger to sent out a sensor report. + Upper limit range: 0 to 100%. + E.g. The default upper limit is 60%, when the measurement is more than 60%, it will be triggered to send out a humidity sensor report. + + + + + When the measurement is less than this lower limit, which will trigger to sent out a sensor report. + Lower limit range: 0 to 100%. + E.g. The default lower limit is 50%, when the measurement is less than 50%, it will be triggered to send out a humidity sensor report. + + + + + When the measurement is more than this upper limit, which will trigger to sent out a sensor report. + Upper limit range: 0 to 30000 Lux. + E.g. The default upper limit is 1000Lux, when the measurement is more than 1000Lux, it will be triggered to send out a Lighting sensor report. + + + + + When the measurement is less than this lower limit, which will trigger to sent out a sensor report. + Lower limit range: 0 to 30000 Lux. + E.g. The default lower limit is 100Lux, when the measurement is less than 100Lux, it will be triggered to send out a Lighting sensor report. + + + + + When the measurement is more than this upper limit, which will trigger to sent out a sensor report. + Upper limit range: 1 to 11. + E.g. The default upper limit is 8, when the measurement is more than 8, it will be triggered to send out a ultraviolet sensor report. + + + + + When the measurement is less than this upper limit, which will trigger to sent out a sensor report. + Lower limit range: 1 to 11. + E.g. The default lower limit is 4, when the measurement is less than 8, it will be triggered to send out a ultraviolet sensor report. + + + + + Note: + 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. + After that, the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). + 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. + After that, the lower limit report would be disabled again until the measurement greater or equal (Lower limit + Recover limit). + 3. High byte is the recover limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). + 4. Recover limit range: 1.0 to 25.5 C/ F (0x0101 to 0xFF01 or 0x0102 to 0xFF02). + E.g. The default recover limit value is 2.0 C/F (0x1401/0x1402), when the measurement is less than (Upper limit - 2), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 2), the lower limit report would be enabled one time. + + + + + Note: + 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. + After that the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). + 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. + After that the lower limit report would be disabled again until the measurement greater or equal(Lower limit + Recover limit). + 3. Recover limit range: 1 to 50% (0x01 to 0x32). + E.g. The default recover limit value is 5%, when the measurement is less than (Upper limit - 5), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 5), the lower limit report would be enabled one time. + + + + + Note: + 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. + After that the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). + 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. + After that the lower limit report would be disabled again until the measurement greater or equal (Lower limit + Recover limit). + 3. Unit = 10*Recover limit (Lux) + 4. Recover limit range: 10 to 2550Lux (0x01 to 0xFF). + E.g. The default recover limit value is 100 Lux, when the measurement is less than (Upper limit - 100), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 100), the lower limit report would be enabled one time. + + + + + Note: + 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. + After that the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). + 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. + After that the lower limit report would be disabled again until the measurement greater or equal(Lower limit + Recover limit). + 3. Recover limit range: 1 to 50% (0x01 to 0x32). + E.g. The default recover limit value is 5%, when the measurement is less than (Upper limit - 5), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 5), the lower limit report would be enabled one time. + + + + + Get the out-of-limit state of the Sensors. + Bit mask = 0, within the limit. + Bit mask = 1, out of the limit. + Bit 0 = temperature. + Bit 1 = humidity. + Bit 2 = luminance. + Bit 3 = ultraviolet. + The above bit masks are used to indicate whether the current measurements of the Sensors are out of the lower limit. + The below bit masks are used to indicate whether the current measurements of the Sensors are out of the upper limit. + Bit 4 = temperature. + Bit 5 = humidity. + Bit 6 = luminance. + Bit 7 = ultraviolet. + + + + Default value: Celsius for EU/AU version, Fahrenheit for US version. + + + + + Enable/disable the LED blinking for motion, wakeup, and sensor report. + + + + + + Reset The Reporting Group Configuration (101 to 103) to default + + + Which reports need to send automatically in timing intervals for group 1. + Bitmask: + 10000000 - 128 - Luminance + 01000000 - 64 - Humidity + 00100000 - 32 - Temperature + 00010000 - 16 - Ultraviolet + 00000001 - 1 - Battery + 10100000 - 160 - Luminance and Temperature (32+128) + 11110001 - 241 - All (1+16+32+64+128) + + + Which reports need to send automatically in timing intervals for group 2. + Bitmask: + 10000000 - 128 - Luminance + 01000000 - 64 - Humidity + 00100000 - 32 - Temperature + 00010000 - 16 - Ultraviolet + 00000001 - 1 - Battery + 10100000 - 160 - Luminance and Temperature (32+128) + 11110001 - 241 - All (1+16+32+64+128) + + + Which reports need to send automatically in timing intervals for group 3. + Bitmask: + 10000000 - 128 - Luminance + 01000000 - 64 - Humidity + 00100000 - 32 - Temperature + 00010000 - 16 - Ultraviolet + 00000001 - 1 - Battery + 10100000 - 160 - Luminance and Temperature (32+128) + 11110001 - 241 - All (1+16+32+64+128) + + + Reset The Reporting Group Interval Configuration (111 to 113) to default + + + + The interval for sending reports for group 1. + The effective behavior of this setting depends on the device's power source: + - If the device is on USB power, it will send the reports at the configured interval; set it to something low (~15-60 seconds) to get frequent updates from a powered device. + - If the device is on battery, the sensor will never report in more often than its configured wake interval, regardless of what this setting is configured to; setting this to 3601 when the wake interval is 3600 would make this group report in every 7200 seconds. 240 seconds is the minimum wake interval, but will quickly use battery. + + + The interval for sending reports for group 2. + The effective behavior of this setting depends on the device's power source: + - If the device is on USB power, it will send the reports at the configured interval; set it to something low (~15-60 seconds) to get frequent updates from a powered device. + - If the device is on battery, the sensor will never report in more often than its configured wake interval, regardless of what this setting is configured to; setting this to 3601 when the wake interval is 3600 would make this group report in every 7200 seconds. 240 seconds is the minimum wake interval, but will quickly use battery. + + + The interval for sending reports for group 3. + The effective behavior of this setting depends on the device's power source: + - If the device is on USB power, it will send the reports at the configured interval; set it to something low (~15-60 seconds) to get frequent updates from a powered device. + - If the device is on battery, the sensor will never report in more often than its configured wake interval, regardless of what this setting is configured to; setting this to 3601 when the wake interval is 3600 would make this group report in every 7200 seconds. 240 seconds is the minimum wake interval, but will quickly use battery. + + + Temperature calibration (the available value range is [-128,127] or [-12.8C,12.7C]). + Note: + 1. High byte is the calibration value. Low byte is the unit (0x01=Celsius,0x02=Fahrenheit) + 2. The calibration value (high byte) contains one decimal point. + E.g. if the value is set to 20 (0x1401), the calibration value is 2.0C (EU/AU version) or if the value is set to 20 (0x1402), the calibration value is 2.0F (US version) + 3. The calibration value (high byte) = standard value - measure value. + E.g. If measure value =25.3C and the standard value = 23.2C, so the calibration value= 23.2C - 25.3C= -2.1C (0xEB). + If the measure value =30.1C and the standard value = 33.2C, so the calibration value= 33.2C - 30.1C=3.1C (0x1F). + Default value: 1 for EU/AU version, 2 for US version. + + + + The calibration value = standard value - measure value. + (the available value range is [-50, 50]). + If measure value =80RH and the standard value = 75RH, so the calibration value= 75RH-80RH = -5RH (0xFB). + If the measure value =85RH and the standard value = 90RH, so the calibration value= 90RH-85RH = 5RH (0x05). + + + + The calibration value = standard value - measure value. + (the available value range is [-1000, 1000]). + If measure value =800Lux and the standard value = 750Lux, so the calibration value= 750-800 = -50 (0xFFCE). + If the measure value =850Lux and the standard value = 900Lux, so the calibration value= 900-850 = 50 (0x0032). + + + + The calibration value = standard value measure value. + (the available value range is [-10, 10]). + If measure value =9 and the standard value = 8, so the calibration value= 8-9 = -1 (0xFE). + If the measure value =7 and the standard value = 9, so the calibration value= 9-7 = 2 (0x02). + + + + + Enable/disable Lock Configuration + + + + + + Reset to factory defaults + + + + + + + + + false + + + + + + + + + diff --git a/openzwave/oomi/ft111.xml b/openzwave/oomi/ft111.xml new file mode 100644 index 00000000..f4dff63e --- /dev/null +++ b/openzwave/oomi/ft111.xml @@ -0,0 +1,249 @@ + + + http://www.openzwave.com/device-database/016A:006F:0103 + images/oomi/ft111.png + https://products.z-wavealliance.org/products/2258/ + Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing. + Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing. + Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + Oomi In-Wall Dimmer is a Z-Wave Smart Dimmer specifically used to enable Z-Wave command and control (on/off/dim) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. +It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Nano Dimmer. +The In-Wall Dimmer is also a security Z-Wave plus device and supports Over The Air (OTA) feature for the products firmware upgrade. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2765/Oomi In-Wall Dimmer manual (FT111-K) - 2.pdf + U.S. / Canada / Mexico + FT111-A + In-Wall Dimmer + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2258/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2273/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2765/xml + + https://products.z-wavealliance.org/products/2273/ + FT111-B + Australia / New Zealand + https://products.z-wavealliance.org/products/2765/ + FT111-K + China + + + + + Output Load will be turned off automatically after 30 seconds and if the current overrun 1.5A. + + + + + Output load will be closed after 30 seconds if the temperature inside the product exceeds 100C. + + + + + Configure the output load status after re-power on + + + + + + To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed + + + + + + + + To set which notification would be sent to the associated nodes in association group 3 when using the external switch 1 to switch the loads + + + + + To set which notification would be sent to the associated nodes in association group 4 when using the external switch 2 to switch the loads + + + + + State appointment + Set the ON time of output load. + Value1 = 0, disable or = non zero, enable (day, bit0 - bit6 represent Mon to Sun). + Value2 = ON (hour) + Value3 = ON (minute) + Value4 = ON (brightness level) + + + + State appointment + Set the ON time of output load. + Value1 = 0, disable or = non zero, enable (day, bit0 - bit6 represent Mon to Sun). + Value2 = ON (hour) + Value3 = ON (minute) + Value4 = ON (brightness level) + + + + Enables/disables parameter 91 and 92 + + + + + The value represents the minimum change in wattage for a Report to be sent (default 25 W) + + + The value represents the minimum percentage change in wattage for a Report to be sent (Default 5) + + + Set report types for groups 1, 2 and 3 to default. + + + + Defines the type of report sent for reporting group 1. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 current + bit 2 voltage + bit 1 watt + bit 0 kWh + + + + + Defines the type of report sent for reporting group 2. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 current + bit 2 voltage + bit 1 watt + bit 0 kWh + + + + + Defines the type of report sent for reporting group 3. + 1 is meter report for voltage. + 2 is meter report for current. + 4 is meter report for watts. + 8 is meter report for kilowatts. + Value 1 (msb) Reserved + Value 2 Reserved + Value 3 Reserved + Value 4 (lsb) bits 7-4 reserved + bit 3 current + bit 2 voltage + bit 1 watt + bit 0 kWh + + + + Set time interval for sending reports for groups 1, 2 and 3 to default. + + + Defines the time interval when the defined report for group 1 is sent. + + + Defines the time interval when the defined report for group 2 is sent. + + + Defines the time interval when the defined report for group 3 is sent. + + + When the mode is determined, this mode value will not be reset after exclusion + + + + + + + + When the mode is determined, this mode value will not be reset after exclusion + + + + + + + + Get the state of touch panel port + + + + + Set the control destination for external switch S1 + + + + + + Set the control destination for external switch S2 + + + + + + Set the default dimming rate + + + Get the current working mode + + + + + + Set the dimming principle + + + + + To get what type of load the Dimmer is connected to + + + + + + + Set the min brightness level that the load can reach to + + + Set the max brightness level that the load can reach to + + + Set the recognition way of load + + + + + + Enable/disable Configuration Locked + + + + + Reset to factory defaults + + + + + + + + + + + + + + + diff --git a/openzwave/oomi/ft112.xml b/openzwave/oomi/ft112.xml new file mode 100644 index 00000000..fba3ea23 --- /dev/null +++ b/openzwave/oomi/ft112.xml @@ -0,0 +1,74 @@ + + + images/oomi/ft112.png + Turn the primary controller into exclusion mode, short press the product’s Action Button that you can find in back of the product. + Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes. + Turn the primary controller into inclusion mode, short press the product’s Action Button that you can find in the back of the product. + Aeon Labs Door/ Window Sensor 6 is a smart Z-Wave sensor that can detect the status of door/window's open/close in real time. +It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs. +It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications. + Door/ Window Sensor 6 + Press the Action Button once that you can find in the back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. + + Initial version - clone of aeotec/zw112 + Add Product Pic + + CEPT (Europe) + FT112-C + + + + + + + Which value of the Sensor Binary Report or Basic Set will be sent when the door is Opened/Closed + + + + + 10% to 50% + + + Enable/disable the low battery checking + + + + + + The minimum interval is 4 minutes + + + + + Configure which sensor report will be sent when the door is Opened/Closed + + + + + + + + Lock/ unlock all configuration parameters + + + + + Reset to factory defaults + + + + + + + + + true + + + + + + + + + diff --git a/openzwave/oomi/ft118.xml b/openzwave/oomi/ft118.xml new file mode 100644 index 00000000..d980d82c --- /dev/null +++ b/openzwave/oomi/ft118.xml @@ -0,0 +1,62 @@ + + + images/oomi/ft118.png + Turn the primary controller of Z-Wave network into exclusion mode, press the Z-Wave Button on Range Extender 6. + Oomi Range Extender is a Z-Wave mesh network repeater which can extend the range of communication between Z-Wave products and assist other devices to reach each other in your Z-Wave network. Clone of Aeotec ZW117 extender 6. +The Range Extender can also communicate securely via AES 128 wireless Z-Wave commands and supports Over-The-Air (OTA) firmware upgrades. + + Range Extender 6 + Press and hold the Z-Wave Button for 20 seconds and then release it. +Use this procedure only in the event that your primary network controller is missing or inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1998/Range Extender 6 manual.pdf + Turn the primary controller of Z-Wave network into inclusion mode, press the Z-Wave Button on Range Extender 6. + + Initial version, cloned from Aeotec ZW117 xml + Add Product Pic + + CEPT (Europe) + FT118-C15 + + + + + false + + + + + + Set the default status of the LED when the Range Extender relays Z-Wave message. + + + + + Partner ID + + + + + Enable/disable Configuration Locked + + + + + Device tag. + + + Reset to factory defaults + + + + + + + + + + + + + diff --git a/openzwave/options.xml b/openzwave/options.xml new file mode 100644 index 00000000..6707030f --- /dev/null +++ b/openzwave/options.xml @@ -0,0 +1,75 @@ + + + + + + diff --git a/openzwave/options.xsd b/openzwave/options.xsd new file mode 100644 index 00000000..e0f5cf79 --- /dev/null +++ b/openzwave/options.xsd @@ -0,0 +1,22 @@ + + + + + + + + + + + + + + + + + + diff --git a/openzwave/permundo/psc132zw.xml b/openzwave/permundo/psc132zw.xml new file mode 100644 index 00000000..d44c9930 --- /dev/null +++ b/openzwave/permundo/psc132zw.xml @@ -0,0 +1,43 @@ + + + http://www.openzwave.com/device-database/0245:0002:0003 + images/permundo/psc132zw.png + https://products.z-wavealliance.org/products/1593/ + Smart Mini Plug + When a PS132ZW that is not associated to a Z-Wave network is inserted into the mains outlet, it will flash once red followed by 2 green flashes followed by steady red flashing. The PSC132ZW can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network: +1) start inclusion/exclusion on the primary + controller +2) hold the touch button until the led + shows green light +3) release the touch button +The PSC234 will confirm successful removal/exclusion by steady red flashing. At the time of exclusion the device is factory reset. + + The wireless flush-mount switching actuator PSC132ZW allows you to remotely control electrical appliances. It features a metering function to measure the power consumption and the accumulated energy usage of connected equipment. The built-in metering unit is of high quality: it calculates the true-power and also works for small loads from 1W upwards. This feature is important to have a correct measurement value also for electronic loads like led lamps. +The PSC132ZW has a built-in safety features that will switch-off the output in case of too high temperature or overload. +Additionally the PSC132 has a feature to switch the load on at zero voltage and switch the load off at zero current. This leads to a very high number of possible switching cycles also for difficult loads like led-lamps or motors, e.g. pumps. + + Please use this procedure only if the primary controller is missing or inoperable: +The device can be put into factory default state manually by the following procedure: +1) hold the touch-button until the led + shows red light +2) release the touch-button and hold the + touch-button again until the led starts + to flash green +The PSC132ZW confirms the successful completion of the factory reset procedure by steady red flashing. + + PSC132ZW + CEPT (Europe) + When a PS132ZW that is not associated to a Z-Wave network is inserted into the mains outlet, it will flash once red followed by 2 green flashes followed by steady red flashing. The PSC132ZW can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network: +1) start inclusion/exclusion on the primary + controller +2) hold the touch button until the led + shows green light +3) release the touch button +The PSC234 will confirm successful addition to the network by 5 green flashes. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1593/PSC132ZW_V07_EN.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1593/xml + + + diff --git a/openzwave/permundo/psc234zw.xml b/openzwave/permundo/psc234zw.xml new file mode 100644 index 00000000..bad7c17d --- /dev/null +++ b/openzwave/permundo/psc234zw.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/0245:0001:0003 + images/permundo/psc234zw.png + https://products.z-wavealliance.org/products/1575/ + The wireless plug socket PSC234ZW allows you to remotely control electrical appliances. It features a metering function to measure the power consumption and the accumulated energy usage of connected equipment. The built-in metering unit is of high quality: it calculates the true-power and also works for small loads from 1W upwards. This feature is important to have a correct measurement value also for electronic loads like led lamps. +The PSC234ZW has a built-in safety features that will switch-off the output in case of too high temperature or overload. +Additionally the PSC234 has a feature to switch the load on at zero voltage and switch the load off at zero current. This leads to a very high number of possible switching cycles also for difficult loads like led-lamps or motors, e.g. pumps. + + PSC234ZW + Smart Plug + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1575/PSC234ZW_V06.pdf + Please use this procedure only if the primary controller is missing or inoperable: +The device can be put into factory default state manually by the following procedure: +1) hold the touch-button until the led + shows red light +2) release the touch-button and hold the + touch-button again until the led starts + to flash green +The PSC234 confirms the successful completion of the factory reset procedure by steady red flashing. + + When a PSC234 that is not associated to a Z-Wave network, is inserted into the mains outlet, it will flash once red followed by 2 green flashed followed by steady red flashing. The PSC234 can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network: +1) start inclusion/exclusion on the primary + controller +2) hold the touch button until the led + shows green light +3) release the touch button + The PSC234 will confirm successful removal/exclusion by steady red flashing. At the time of exclusion the device is factory reset. + CEPT (Europe) + When a PSC234 that is not associated to a Z-Wave Network, is inserted into the mains outlet, it will flash once red followed by 2 green flashed followed by steady red flashing. The PSC234 can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network: +1) start inclusion/exclusion on the primary + controller +2) hold the touch button until the led + shows green light +3) release the touch button +The PSC234 will confirm successful addition to the network by 5 green flashes. +The PSC234 will confirm successful removal/exclusion by steady red flashing. At the time of exclusion the device is factory reset. + + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1575/xml + + + diff --git a/openzwave/philio/pad02.xml b/openzwave/philio/pad02.xml new file mode 100644 index 00000000..1cfb8773 --- /dev/null +++ b/openzwave/philio/pad02.xml @@ -0,0 +1,73 @@ + + + http://www.openzwave.com/device-database/013C:0031:0005 + images/philio/pad02.png + https://products.z-wavealliance.org/products/2355/ + Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing Include button of PAD02 three times within 2 seconds will enter inclusion mode. +2. Within 1 second, press Include button of PAD02 again for 5 seconds. +3. IDs are excluded. + PAD02 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2355/PAD02-A1 manual-20170405.pdf + 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing Include button of PAD02 three times within 2 seconds will enter exclusion mode. +3. Node ID has been excluded. + Z-Wave Smart Dimmer Socket + CEPT (Europe) + PAD02 is an E27(EU)/ E26(US) Edison screw based lamp socket, which provides electrical connection to the E14(EU)/ E12(US) Edison screw based lamps and support it in the lighting fixture. The use of socket allows lamps to be safely and conveniently replaced. You can On/Off the light by pressing the button briefly, or a long pressing to control the brightness of dimmable lightbulb. +This dimmer is a transceiver which is a security enabled device which based on Z-Wave Plus technology. Z-Wave PlusTM enabled devices displaying the Z-Wave PlusTM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z- WaveTM enabled networks. Remote dim level control of the connected light is possible with other manufacturer’s wireless Controller. Since PAD02 supports Security Command Class, it can learn with a Secured enabled controller to fully utilize the device. Its functionality and supported command classes is identical when included as a secure and non-secure device. + +Adding to Z- WaveTM Network +In the front casing, there is an on/off button with LED indicator below which is used to switch on and off, dim level, or carries out add, remove, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion. + +Auto Inclusion +The function of auto inclusion will be executed as long as the dimmer does not have Node ID and just connect the dimmer to main power. Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the dimmer. + + 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing Include button of PAD02 three times within 2 seconds will enter inclusion mode. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2355/xml + + + + + + + + Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_ REPORT to the nodes of group1. + The default setting is Enable the function. + + + + + + + Show dimmer State: When dimmer is on, LED is on. When dimmer is off, LED is off. + Show Night mode: When dimmer is on, LED is off. When dimmer is off, LED is on. + One flash mode: When dimmer on/off state changes, LED will light on one second and then off. + + + + + + + + Whenever the AC power return from lost, PAD02 will restore the switch state which could be Dimmer off, Last dimmer state, Dimmer on. + The default setting is Last dimmer state. + + + + + + + + + + + + + + diff --git a/openzwave/philio/pan03.xml b/openzwave/philio/pan03.xml new file mode 100644 index 00000000..584bff5a --- /dev/null +++ b/openzwave/philio/pan03.xml @@ -0,0 +1,67 @@ + + + + + + If the setting is configured for 1 hour (set value =720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. Unit: 5 seconds. + + + If the setting is configured for 1hour (set value =6), the Micromodule will report its Accumulated Power Consumption (KW/h) every 1 hour to Z-Wave Controller. 10min. + + + This is a warning when the current of load over the preset threshold value, if the setting value is 1100 (11A), when the load current of Relay1 over this value, Micromodule will send current meter report to warn the Z-Wave Controller. Unit: 0.01A + + + This is a warning when the KWh of load over the preset threshold value, if the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, Micromodule will send KWH meter report to warn the Z-Wave Controller. Unit: 1KWh + + + Whenever the AC power return from lost, Micromodule will restore the switch state which could be + SWITCH OFF + LAST SWITCH STATE + SWITCH ON + + + + + + The On/Off function of S1, S2 and learn switch can be disabled or enabled by this parameter, default value is Enable. But the learning operation won't be affected. When manual On/Off function is disabled, the RF command can only switch On but not Off. This is useful function for keeping the device in switch on state. + + + LED Indication Mode: + 1: SHOW SWITCH STATE: When switch is on, LED is on. When switch is off, LED is off. The default setting is Show Switch State. : + 2 :SHOW NIGHT MODE: When switch is on, LED is off. When switch is off, LED is on. + 3 : ONE FLASH MODE: When the state of switch changes, LED will be on only one second, then LED keeps off. + + + Whenever Micromodule switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0. + + + Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands: + 0: SWITCH OFF:It switches to OFF state. The default setting is Switch Off. + 1: IGNORE:The switch off command will be ignored. + 2: SWITCH TOGGLE:It switches to the inverse of current state. + 3 :SWITCH ON:It switches to ON state + + + Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode. + 1: EDGE MODE: This mode is suitable for the bi-stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1. If the Micromodule relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state. Manual switch S2 is disabled in this mode. + 2: PULSE MODE: This mode is suitable for the toggle type wall switch to swap the state of Relay1. + 3 :EDGE-TOGGLE MODE: This mode is suitable for the normal bi-stable switch, wheneverchange the state of the wall switch will also swap the state of Relay1. + + + + + true + + + + + + + + + + + + + diff --git a/openzwave/philio/pan04.xml b/openzwave/philio/pan04.xml new file mode 100644 index 00000000..de370fc3 --- /dev/null +++ b/openzwave/philio/pan04.xml @@ -0,0 +1,101 @@ + + + + http://www.openzwave.com/device-database/013C:0003:0001 + images/philio/pan04.png + https://products.z-wavealliance.org/products/851/ + PAN04-2 + http://philio-tech.com/ + CEPT (Europe) / U.S. / Canada / Mexico + This in-wall dual relay switch module is a transceiver which is a Z-Wave Plus™ enabled device and is fully compatible with any Z-Wave™ enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of +application by using the module to switch AC power On and Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. + +This in-wall switch module is able to detect Instant power wattage and overload current (7.5A) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status. + + In Wall Dual relay(1 way) switch module + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/820/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/851/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1148/xml + Updated Config Params + + https://products.z-wavealliance.org/products/1148/ + 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode. + PAN04-1A + CEPT (Europe) + This procedure should only be used in the event the primary controller is lost or otherwise inoperable. + +1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode. +2. Within 1 second, press INCLUDE_BUTTON again for 5 seconds. +3. IDs are excluded. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1148/PAN04-1-2-3A manual-20140918.pdf + 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode. + + + + + If the setting is configured for 1hour (set value =720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. Unit: 5 seconds. + + + If the setting is configured for 1hour (set value =720), the device will report its power consumption in KWh every 1 hour to Z-Wave Controller. Unit: 5 seconds. + + + 1: Relay 1 and Relay 2. 2: Relay 1. 3: Relay 2 + + + Edge or Pulse mode or Edge-Toggle mode defines the operating mode of the externally connected switch. Default: Edge Mode + + + + + + Threshold of Watt for Load Caution + + + Threshold of kWh for Load Caution + + + + + + + + 0: Disable auto off function. 1-32767: 1s ~32767s + + + + + + + + + + + + + Can repair problems with bad switch selected + + + + + + + true + + + + + + + + + + + + + + + diff --git a/openzwave/philio/pan05.xml b/openzwave/philio/pan05.xml new file mode 100644 index 00000000..f5371995 --- /dev/null +++ b/openzwave/philio/pan05.xml @@ -0,0 +1,87 @@ + + + http://www.openzwave.com/device-database/013C:0010:0001 + images/philio/pan05.png + https://products.z-wavealliance.org/products/1663/ + CEPT (Europe) + 1.Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. +2.Pressing Include button of PAN05 three times within 2 seconds will enter exclusion mode. +3.Node ID has been excluded. + This in-wall switch module is a transceiver which is a security enabled device which based on Z-Wave Plus technology, and it is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. Since PAN05 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. +There are many kind of application by using the module to switch Load On and Off, one main application is the light control. If connect the COM terminal directly to AC Line terminal, the new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This module can also connect to alternative power supply like DC 12V to switch on/off 12V MR-16 light. + +Adding to Z-WaveTM Network +In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carries out add, remove, reset or association. When first power applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion. + +Auto Inclusion +The function of auto inclusion will be executed as long as the in wall switch does not have Node ID and just connect the switch to main power. +Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike “Add” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch. + 1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. +2.Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode. + Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1.Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode. +2.Within 1 second, press Include button of PAN05 again for 5 seconds. +3.IDs are excluded. + In Wall Single relay(1way) switch module + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1663/PAN05-1-2-3B manual-20160215.pdf + PAN05-1B + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1149/xml + Fix WhiteSpace Error + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1663/xml + + + + + + To match different kind of external switches, the inputs S1 and S2 can be set to either Edge Mode, Pulse Mode or Edge/Toggle Mode. Edge Mode: The Position of the external switch determines the switching state of the relay. After a wireless switching command it may be needed to operate the switch twice to return to the direct relation of switch position and relay state. Toggle Mode: Each ON-Position of the external switch will toggle the state of the relays. This mode is particularly suited for mono-stable switches. Edge/Toggle-Mode: Every change of the state of the external switch results in a change of the relay state. Default setting: Edge Mode + + + + + + When the AC power returns, e.g. after a power failure, the relay states can be set to Off, On or to retain it's last state . Default setting: Retain last state + + + + + + The On/Off function of S1,S2 and learn switch can be disabled or enabled by this parameter, default value is Enable. But the learning operation wont be affected. When manual On/Off function is disabled, the RF command can only switch On but not Off. This is useful function for keeping the device in switch on state + + + + + Controls the light indicator in the device + Switch State: When switch is on, LED is on. When switch is off, LED is off. (default) + Night mode: When switch is on, LED is off. When switch is off, LED is on. + One flash: When the device changes state, the LED illuminates for one second. + + + + + + + After being switched on, the relays can be set to automatically switch off after the specified time. Available settings: 1-32767: time in seconds, 0: function disabled. Default setting: 0 + + + Action when a Z-Wave Off command is received. Default setting: Switch Off + + + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/philio/pan06.xml b/openzwave/philio/pan06.xml new file mode 100644 index 00000000..90ebf6a7 --- /dev/null +++ b/openzwave/philio/pan06.xml @@ -0,0 +1,80 @@ + + + http://www.openzwave.com/device-database/013C:0004:0001 + images/philio/pan06.png + https://products.z-wavealliance.org/products/854/ + PAN06-2 + In-Wall Switch Module + CEPT (Europe) / U.S. / Canada / Mexico + Features: +- World first two relay Z-wave 400 series module in a very slim case. +- Input voltage AC100~240V / DC24~60V. +- Adopt Z-Wave protocol to secure the success of wireless two way communication. +- Slim design, easy install. +- Adopt newest Z-wave 400series chip, support multichannel operation and higher data rate (9.6/40/100kbps). +- Resistive load 1500W X 2. +- Two dry contact relay. +- Z-Wave V6.02 +- Very low electricity consumption, meet Europe year 2012 energy-related products requirement directive 2009/125/EC no. 1275/2008. +- LVD:EN 60669-2-1:2004+A1:2009+A12:2010, +- EN 60669-2-2 :2006 +- EN 60669-1:1999+A1:2002+A2:2008+IS1:2009 +- R&TTE: EN 301489, EN 300200, + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/822/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/854/xml + + http://philio-tech.com/ + + + + + If the controller treats this device as a single channel relay/switch, you may select which one of the relays that will report and respond to commands. Default setting: Relay 1 + Relay 2 + + + + + + To match different kind of external switches, the inputs S1 and S2 can be set to either Edge Mode, Pulse Mode or Edge/Toggle Mode. Edge Mode: The Position of the external switch determines the switching state of the relay. After a wireless switching command it may be needed to operate the switch twice to return to the direct relation of switch position and relay state. Toggle Mode: Each ON-Position of the external switch will toggle the state of the relays. This mode is particularly suited for mono-stable switches. Edge/Toggle-Mode: Every change of the state of the external switch results in a change of the relay state. Default setting: Edge Mode + + + + + + When the AC power returns, e.g. after a power failure, the relay states can be set to Off, On or to retain it's last state . Default setting: Retain last state + + + + + + After being switched on, the relays can be set to automatically switch off after the specified time. Available settings: 1-32767: time in seconds, 0: function disabled. Default setting: 0 + + + Action when a Z-Wave Off command is received. Default setting: Switch Off + + + + + + + The endpoint3 of Multi-Channel Command Class is related to relay1 and relay2. It may be redundant for the need to control relay1 or relay2 individually. When the Existence of Endpoint3 is set as 0, the endpoint3 of Multi-Channel Command Class will be disabled. Default setting: Endpoint3 disable + + + + + + + true + + + + + + + + + + + + + diff --git a/openzwave/philio/pan07.xml b/openzwave/philio/pan07.xml new file mode 100644 index 00000000..3f8cd1af --- /dev/null +++ b/openzwave/philio/pan07.xml @@ -0,0 +1,60 @@ + + + + + + + If the setting is configured for 1hour (set value =720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. Unit: 5 seconds. + + + If the setting is configured for 1hour (set value =6), the device will report its power consumption in KWh every 1 hour to Z-Wave Controller. Unit: 10 minutes. + + + Selected end points + + + + + + Edge or Pulse mode or Edge-Toggle mode defines the operating mode of the externally connected switch. Default: Edge Mode + + + + + + Threshold of Current for Load Caution. Unit 0.01A + + + Threshold of kWh for Load Caution. Unit 1KWh + + + Relay control mode. Default: Power mode + + + + + Restore switch state mode + + + + + + Whether endpoint 3 exists. + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/philio/pan08.xml b/openzwave/philio/pan08.xml new file mode 100644 index 00000000..2f561085 --- /dev/null +++ b/openzwave/philio/pan08.xml @@ -0,0 +1,59 @@ + + + http://www.openzwave.com/device-database/013C:0006:0001 + images/philio/pan08.png + https://products.z-wavealliance.org/products/891/ + CEPT (Europe) / U.S. / Canada / Mexico + http://www.philio-tech.com/p_switch.htm + The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter connected to its terminals using radio waves, controllers and a push button directly connected to this Roller Controller. +This in-wall Roller Shutter Controller is a transceiver which is a Z-Wave Plus™ enabled device and is fully compatible with any Z-Wave™ enabled network. Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration. +The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter. +This in-wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method, so it can be remote controlled not only fully up or down, but also can be adjusted to ex. 30% or 50%. And when manual controlled by push button, the controller also can memorize the position and send the new shutter position to its controller (ex. IP-Gateway). + Roller shutter controller + PAN08-2 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/880/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/891/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1164/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2580/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2914/xml + + https://products.z-wavealliance.org/products/2914/ + Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing Include button three times within 2 seconds will enter inclusion mode. +2. Within 1 second, press Include button again for 5 seconds. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2914/PAN08 manual-20180423.pdf + CEPT (Europe) / Brazil / Japan + 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing Include button three times within 2 seconds will enter inclusion mode. + 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing Include button three times within 2 seconds will enter exclusion mode. + PAN08-3 + + + + + Watt Meter Report Period. Unit: 5 seconds. + + + kWH Meter Report Period. Unit: 10 minutes. + + + Threshold of Watt for Load Caution. Unit: 1 watt + + + Threshold of kWH for Load Caution. Unit: 1 kWH + + + External switch type: 1-> One Push button, 2->Two Push button + + + Level report mode: 1-> Report destination level in 5s, 2-> Report 10 percent level while running + + + + + + + + diff --git a/openzwave/philio/pan11-1.xml b/openzwave/philio/pan11-1.xml new file mode 100644 index 00000000..b7ad1a0d --- /dev/null +++ b/openzwave/philio/pan11-1.xml @@ -0,0 +1,27 @@ + + + http://www.openzwave.com/device-database/013C:0001:0001 + images/philio/pan11-1.png + https://products.z-wavealliance.org/products/855/ + PAN11-4 + CEPT (Europe) / U.S. / Canada / Mexico + Features: +- Higher RF output power (+2.5dBm output power as compared to -2.5dBm 300 series Z-wave module) to enhance the communication range +- Adopt Z-Wave protocol to secure the success of wireless two way communication +- Easy install +- Very low no load power consumption, meet Europe year 2012 energy-related products requirement directive 2009/125/EC no. 1275/2008 +- Resistive load 1400W +- Overload protection +- Voltage, Current, Power factor, Instant power Wattage and Accumulated power consumption KWh report +- Z-Wave V6.02 +- UL, FCC part15B+C LVD + Smart Energy Plug In Switch + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/780/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/783/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/784/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/855/xml + + http://philio-tech.com/ + + diff --git a/openzwave/philio/pan11.xml b/openzwave/philio/pan11.xml new file mode 100644 index 00000000..e6674779 --- /dev/null +++ b/openzwave/philio/pan11.xml @@ -0,0 +1,96 @@ + + + http://www.openzwave.com/device-database/013C:0011:0001 + images/philio/pan11.png + https://products.z-wavealliance.org/products/1598/ + CEPT (Europe) + Use this procedure only in the event that the primary controller is lost or otherwise inoperable. + +1. Pressing On/Off button three times within 2 seconds will enter inclusion mode. Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +2. Within 1 second, press On/Off button again for 5 seconds. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1598/PAN11-1B manual-20151204.pdf + 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing On/Off button three times within 2 seconds will enter inclusion mode. + Smart Energy Plug In Switch + 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing On/Off button three times within 2 seconds will enter exclusion mode. + PAN11-1B + This plug-in ON/OFF switch PAN11 is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave PlusTM enabled devices displaying the Z-Wave PlusTM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-WaveTM enabled networks. Remote On/Off control of the connected load is possible with other manufacturer’s wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because PAN11 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. + +This plug-in ON/OFF switch is able to detect instance wattage (3000W/CE/CN, 1560W/UL/TW/JP) and overload current (14.5A with resistive load) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status. + +Adding to Z-WaveTM Network + +In the front casing, there is an On/Off button with LED indicator which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion. + +Auto Inclusion + +The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall outlet. + +Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once several seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1088/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1598/xml + + + + + + + + If the setting is configured for 1 hour(set value=720), the device will report its instant power consumption every 1 hour to Z_Wave controller. Unit: 5 secs, Min: 1, Max: 32767, Default: 720 + + + If the setting is configured for 1hour (set value =6), the PAN11 will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). + + + This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, PAN11 will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300. + + + This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, PAN11 will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kWh. + + + + Whenever the AC power return from lost, PAN11 will restore the switch state which could be SWITCH OFF, LAST SWITCH STATE, SWITCH ON. The default setting is LAST SWITCH STATE. + + + + + + + + When the mode of switch On/Off is set to 0, any command of switch off will be disabled and the On/Off function of include button will be disabled. The default setting is enable mode. When manual On/Off function is disabled, the RF command can only switch On but not Off. This is useful function for keeping the device in switch on state. + + + + + + + Show Switch State:When switch is on, LED is on. When switch is off, LED is off. The default setting is Show Switch State. Show Night mode:When switch is on, LED is off. When switch is off, LED is on. One Flash mode:When the state of switch changes, LED will be on only one second, then LED keeps off. + + + + + + + Whenever PAN11 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0. + + + + Whenever a switch off command (BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF) is received, it could be interpreted as 4 variety of commands. Switch Off: It switches to OFF state. The default setting is Switch Off. Ignore: The switch off command will be ignored. Switch Toggle: It switches to the inverse of current state. Switch On: It switches to ON state. + + + + + + + + + + + + + + diff --git a/openzwave/philio/pan16.xml b/openzwave/philio/pan16.xml new file mode 100644 index 00000000..8c5d843e --- /dev/null +++ b/openzwave/philio/pan16.xml @@ -0,0 +1,100 @@ + + + http://www.openzwave.com/device-database/013C:0029:0001 + images/philio/pan16.png + https://products.z-wavealliance.org/products/3168/ + PAN16-4 + Smart energy plug in switch + 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing On/Off button three times within 2 seconds will enter inclusion mode. + CEPT (Europe) + 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing On/Off button three times within 2 seconds will enter exclusion mode. + + Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing On/Off button three times within 2 seconds will enter inclusion mode. +2. Within 1 second, press On/Off button again for 5 seconds. +3. IDs are excluded. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3168/PAN16manual.pdf + This plug-in ON/OFF switch PAN16 is a security enabled Z-Wave Plus product, based on Z-Wave Plus technology. The device will enable security mode automatically if the controller supports security mode, too. Z-Wave PlusTM enabled devices displaying the Z-Wave PlusTM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-WaveTM enabled networks. Remote On/Off control of the connected load is possible with other manufacturer’s wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because PAN16 supports Security Command Class, it can learn with a Secured enabled Z-Wave controller to fully utilize the device. Its functionality and supported command classes is identical when included as a secure and non-secure device. +This plug-in ON/OFF switch is able to detect instance wattage (3000W/230Vac) (13Ampere) and overload current (14.5A with resistive load) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status. +Adding to Z-WaveTM Network +In the front casing, there is an On/Off button with LED indicator which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion. +Auto Inclusion +The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall outlet. +Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once several seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch. + + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2001/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3162/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3164/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3168/xml + + + + + + + + The interval at which the device reports its instant power consumption to Group 1 nodes. Unit: 5 secs, Min: 1, Max: 32767, Default: 720 (= 1 hr) + + + The interval at which the device reports its accumulated energy consumption, in kWh, to all Group 1 nodes. Unit: 10 minutes, min: 1, max: 32767, default: 6 (= 1 hr) + + + When the current through the device exceeds this threshold, a current meter report will be sent to Group 1 nodes. min: 10, max: 1100, default: 1100 (= 11 A) + + + When the energy consumption through the device exceeds this threshold, a kWh report will be sent to Group 1 nodes. min: 1, max: 10000, default: 10000 kWh + + + After loss of power, device state will be set according to this parameter, default: Previous state. + + + + + + When set to Disable, all commands to switch off the device are ignored, both via radio and the include button. default: Enable + + + + + Controls the light indicator in the device + Switch State: When switch is on, LED is on. When switch is off, LED is off. (default) + Night mode: When switch is on, LED is off. When switch is off, LED is on. + One flash: When the device changes state, the LED illuminates for one second. + + + + + + + Controls the auto-off timer + 0: The auto off timer is disabled (default) + 1-32767: After switching on, the device will automatically switch off after this time + + + + Controls how the device reacts to the SWITCH_ALL_OFF command + Off: The device switches off (default) + Ignore: The switch off command is ignored + Toggle: It switches to the inverse of current state + On: The device switches on + + + + + + + + + + + + + + diff --git a/openzwave/philio/phpab01.xml b/openzwave/philio/phpab01.xml new file mode 100644 index 00000000..aae77e23 --- /dev/null +++ b/openzwave/philio/phpab01.xml @@ -0,0 +1,66 @@ + + + http://www.openzwave.com/device-database/013C:001A:0006 + images/zipato/phpab01.png + https://products.z-wavealliance.org/products/2420/ + This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Zipato Energy Meter monitors total electricity consumption of connected appliances and reports it to Zipato or any other Z-Wave enabled controller in real time. Small and compact size allows easy installation in majority of electricity distribution boxes. It supports two loads upto 6000W each (@ 120V). + ph-pab01 + Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. +Pressing On/Off (Include) button three times within 2 seconds will enter inclusion mode. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2420/ph-pab01 - MM Energy Meter User Manual v1.1 - Print.pdf + CEPT (Europe) + Micromodule Energy Meter, Z-Wave + Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. +Pressing On/Off (Include) button three times within 2 seconds will enter inclusion mode. +Within 1 second, press and hold On/Off (Include) button again for 5 seconds until LED is off. +IDs are excluded. + Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. +Pressing On/Off (Include) button three times within 2 seconds will enter exclusion mode. +Node ID has been excluded. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1599/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2420/xml + + + + + + + + true + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/philio/phpat02.xml b/openzwave/philio/phpat02.xml new file mode 100644 index 00000000..de3c8e47 --- /dev/null +++ b/openzwave/philio/phpat02.xml @@ -0,0 +1,140 @@ + + + http://www.openzwave.com/device-database/013C:001F:0002 + images/philio/phpat02.png + https://products.z-wavealliance.org/products/2875/ + PAT02-5A + CEPT (Europe) / Russia / Russia + This is a Z-WaveTM plus product, it supports security OTA with the newest features of the Z-Wave technology. Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances + Датчик протечки (Leakage sensor) + After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting commands. +The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. + +Press the tamper key once. The device will wake-up 10 seconds. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2875/PAT02_Manual.pdf + 1. Have Z-WaveTM Controller entered exclusion mode. + 2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. +Node ID has been excluded. + + Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. + 1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON. + 2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. + 3. IDs are excluded and all settings will reset to factory default. + + 1. Have Z-WaveTM Controller entered inclusion mode. + 2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode. + 3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1186/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1299/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1450/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2834/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2875/xml + + + + + + + Setting the BASIC command value. + When the flood trigger off(0x00), send the BASIC CC to the group 2 + + + + + Setting the BASIC command value. + When the flood trigger on(0xFF), send the BASIC CC to the group 2 + + + + + Bit0: Disable the Flood function. + Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius + Bit5: Disable the temperature report after event triggered. (1:Disable,0:Enable) + + + + + Bit6: Disable the humidity report after event triggered. (1:Disable, 0:Enable) + + + + + Bit3: Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable) + Bit4: Notification Type. (0: Using Notification Report, 1: Using Sensor Binary Report) + Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable) + Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) + + + + + The interval time for auto report the battery level. + 0 means turn off auto report. + The default value is 12. + The tick time can be set by the configuration No.20. + + + + + The interval time for auto report the temperature. + 0 means turn off auto report. + The default value is 12. + The tick time can be set by the configuration No.20. + + + + + The interval time for auto report the humidity. + 0 means turn off auto report. + The default value is 12. + The tick time can be set by the configuration No.20. + + + + + The interval time for auto report the flood state. + 0 means turn off auto report. + The default value is 12. + The tick time can be set by the configuration No.20. + + + + + The interval time for auto report each tick. + Setting this configuration will effect configuration No.10, No.13, No.14 and No.15. + Units of one minute. + Caution1: Setting to 0 means turn off all auto report function. + Caution2: The value is unsigned byte + + + + + The temperature differential to report. + 0 means turn off this function. The unit is Fahrenheit. + Enable this function the device will detect every 10 seconds. + And when the temperature is over 140 degree Fahrenheit, it will continue report. + + + + + The humidity differential to report. + 0 means turn off this function. + The unit is percentage. Enable this function the device will detect every 10 seconds. + + + + + + + true + + + + + + + + + + diff --git a/openzwave/philio/phpsg01.xml b/openzwave/philio/phpsg01.xml new file mode 100644 index 00000000..98bb9f72 --- /dev/null +++ b/openzwave/philio/phpsg01.xml @@ -0,0 +1,70 @@ + + + http://www.openzwave.com/device-database/013C:001E:0002 + images/philio/phpsg01.png + https://products.z-wavealliance.org/products/2868/ + Датчика дыма (Smoke sensor) + This is the Z-WaveTM plus Smoke Sensor, it supports security OTA with the newest features of the Z-Wave technology. Z-Wave is a wireless +communication protocol designed for home automation, specifically to +remotely control applications in residential and light commercial +environments. The technology uses a low-power RF radio embedded or +retrofitted into home electronics devices and systems, such as lighting, +home access control, entertainment systems and household appliances. + 1. Have Z-Wave Controller entered inclusion mode. + 2. Pressing button three times within 1.5 seconds will enter the inclusion mode. + 3. After add successful, the device will wake to receive the setting command from Z-Wave Controller, about 20 seconds. + + 1. Have Z-Wave Controller entered exclusion mode. + 2. Pressing button three times within 1.5 seconds to enter the exclusion mode. Node ID has been removed. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2868/PSG01_Manual-2015-06-12.pdf + Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. + 1. Pressing button four times within 1.5 seconds and do not release the button in the 4th press, the red LED will light be ON. + 2. After the red LED flash 9 times, release the button within 2 seconds. + 3. IDs are removed and all settings will reset to factory default. + PSG01 + CEPT (Europe) / Russia / Russia + After the device is added to the network, it will wake-up once per day in default. When it wakes-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds to receive the setting commands. +The wake-up interval minimum setting is 30 minutes, the maximum setting is 120 hours, the interval step is 30 minutes. + +If the user wants to wake-up the device immediately, please press the button once. The device will wake-up 10 seconds. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1167/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2835/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2868/xml + + + + + + + Customer function switch, using bit control. + Bit0: Reserve. + Bit1: Reserve. + Bit2: Reserve => 1. + Bit4: Notification Type (0: Notification Report, 1: Sensor Binary Report). + Bit5: Reserve. + Bit6: Reserve. + Bit7: Reserve. + + + + + The interval time for auto report the battery level. + 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) + + + + + + + true + + + + + + + + + diff --git a/openzwave/philio/pse02.xml b/openzwave/philio/pse02.xml new file mode 100644 index 00000000..62de4031 --- /dev/null +++ b/openzwave/philio/pse02.xml @@ -0,0 +1,69 @@ + + + http://www.openzwave.com/device-database/013C:000A:0004 + images/zipato/pse02.png + https://products.z-wavealliance.org/products/2419/ + 1. Have Z-Wave Controller entered inclusion mode. +2. Pressing tamper key three times within 1.5 seconds +to enter the inclusion mode. +3. After add successful, the LED will light ON 1 second + Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4 pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to factory default. + Indoor Siren, Multisound, Z-wave + 1. Have Z-Wave Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. +Node ID has been excluded. + Zipato Indoor Siren is a wireless siren, based on Z-Wave technology. It is the Z-Wave plus product, it supports the security, OTA... all the newest features of the Z-Wave technology. + ph-pse02.eu + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2419/Zipato_Siren-UserManual.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2266/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2419/xml + + + + + + + bit 0 Notification Type: 0: Using Notification Report, 1: Using Sensor Binary Report. + bit 7 Other sounds: 0: Disabled, 1: Enable. + + + + + + + + + Disable the alarm function. + 1: Disable Alarm, + 0: Enable Alarm. + Caution: After the power up, this configuration is always 0. + + + + + + + Play alarm sound duration, + 1 tick is 30 seconds. Default is 3 minutes, maximum is 63.5 minutes. + 0 means never auto stop. + + + + + + + true + + + + + + + + + diff --git a/openzwave/philio/psm02.xml b/openzwave/philio/psm02.xml new file mode 100644 index 00000000..c5a64f96 --- /dev/null +++ b/openzwave/philio/psm02.xml @@ -0,0 +1,151 @@ + + + http://www.openzwave.com/device-database/013C:0002:0002 + images/philio/psm02.png + https://products.z-wavealliance.org/products/836/ + PSM02-2 + Multi-sensor PSM02 has PIR, door/window, temperature and illumination, 4 sensors function in one, based on Z-Wave technology. + +Features + + - (1)Door/window (2)PIR (3)illumination and (4)temperature functions in one sensor + - Adopt newest Z-wave 400 series chip, support multichannel operation and higher data rate (9.6/40/100kbps) + - Higher output power (+2.5dBm output power as compared to -2.5dBm 300 series Z-wave module) to enhance the communication range + - 1500mA CR123A lithium battery to guarantee 2 year battery life + - Built in light sensor while applied to light control + - Adopt Z-Wave protocol to secure the success of wireless two way communication + - With Tamper proof protection + - Easy install + - Low battery indication + - Z-Wave V6.02 + - Auto report the open/close status and battery status + - FCC part15.249 / EN300 220-1/ certification + - NCC + PSM02-2 Multi-Sensor + CEPT (Europe) / Japan / U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/821/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/835/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/836/xml + Fix Philio door sensors #1898 + + http://philio-tech.com/ + + + + + + Setting the BASIC command value to turn on the light. The 0xFF (255) means turn on the light. + For dimmer equipment 1 to 100 means the light strength. + + + + + PIR sensitivity settings. + 0 means disable the PIR motion. + 1 means the lowest sensitivity. + 99 means the highest sensitivity. + High sensitivity means can detect long distance, but if there is more noise signal in the environment, it will re-trigger too frequently. + + + + + Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower than + the threshold, the device will turn on the light. + 0 means turn off illumination detected function and never turn on the light. + 1 means darkest. + 99 means brightest. + 100 means turn off illumination detected function. And always turn on the light. + * Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. + + + + + Bit 0: 1 means security mode; 0 means home automation mode. + Bit 1: 1 means enable test mode; 0 means disable test mode + * Notice * Bit 0 and bit 1 will effect when the DIP Switch setting to program mode. If bit1 is enabled, the bit0 is useless. + Bit 2: Reserved, always 1. + Bit 3: Setting the temperature scale; 0: Fahrenheit, 1:Celsius + Bit 4: Disable illumination report after event triggered. + Bit 5: Disable temperature report after event triggered + + + + + Multi-Sensor Function switch. Using bit to control. + Bit 0: Reserved, always 1. + Bit 1: Disable PIR integrate Illumination. + Bit 2: Reserved, always 1. + Bit 3: Reserved. + Bit 4: Reserved. + Bit 5: Reserved. + Bit 6: Enable temperature monitoring. When this bit enabled, the temperature changed 3 degree Fahrenheit, it will report. + And also the temperature over 140 degree Fahrenheit, it will report every 64 seconds. + + + + + Customer function switch, using bit control. + Bit 0: Reserve. + Bit 1: Enable sending motion OFF report (0:Disable, 1:Enable). + Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00. + Bit 2: Enable PIR super sensitivity mode (0:Disable, 1:Enable). + Bit 3: Disable send out BASIC OFF after door closed (1:Disable, 0:Enable). + Bit 4: Notification Type (0: Notification Report, 1: Sensor Binary Report). + Bit 5: Disable Multi CC in auto report (1:Disable, 0:Enable). + Bit 6: Disable to report battery state when the device triggered (1:Disable, 0:Enable) + Bit 7: Reserve. + ozw recommended setting: 00010110 : 22 + + + + + In the security mode, after the PIR report motion detected, setting the re-detect time. 8 seconds per tick, and minimum time is 24 seconds, default tick is 3 (24 seconds). + Setting the suitable value to prevent received the trigger signal too frequency. Also can save the battery energy. + * Notice * If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not detecting. + + + + + After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected. + 8 seconds per tick, and minimum time is 32 seconds, default tick is 4 (32 seconds). + + + + + The interval time for auto report the battery level. + 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) + + + + + The interval time for auto report the illumination. + 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) + + + + + The interval time for auto report the temperature. + 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/philio/psp05.xml b/openzwave/philio/psp05.xml new file mode 100644 index 00000000..fb4a5300 --- /dev/null +++ b/openzwave/philio/psp05.xml @@ -0,0 +1,112 @@ + + + http://www.openzwave.com/device-database/013C:0050:0002 + images/philio/psp05.png + https://products.z-wavealliance.org/products/2068/ + CEPT (Europe) / Australia / New Zealand / U.S. / Canada / Mexico + PSP05 + The PIR sensor PSP05 has PIR sensor function,based on Z-Wave™ technology. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2068/PSP05_manual.pdf + There is a button on PSP05. +1. Pressing button for about 5 seconds. +2. IDs are excluded and all settings will reset to factory default. +Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. + There is a button on PSP05. +1. Have Z-Wave™ Controller entered inclusion mode. +2. Pressing button once to enter the inclusion mode. +3. After add successful, the device will wake to receive the setting command from Z-Wave™ Controller about 20 seconds. + There is a button on PSP05. +1. Have Z-Wave™ Controller entered exclusion mode. +2. Pressing button once to enter the exclusion mode. + Single Function PIR Sensor + There is a button on PSP05. +Press the button once, the device will awake 10 seconds. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2002/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2037/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2068/xml + + + + + + + Setting the BASIC command value to turn on the light. The 0xFF (-1) means turn on the light. + For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. + + + + + 0 means disable the PIR motion. + 1 means the lowest sensitivity. + 99 means the highest sensitivity. + High sensitivity means can detected long distance, but if there is more noise signal in the invironment, it wil re-trigger too frequent. + + + + + Multi-Sensor Function switch. Using bit to control. + Bit 0: Reserved always 0 + Bit 1: Reserved always 0 + Bit 2: Reserved always 1 + Bit 3: Are the device and the lighting in the same room? 0: In the same room(Default), 1: In the different room. + Bit 4: Disable delay 5 seconds to turn off the light, when door/window closed. + Bit 5: Disable auto turn off the light, after door/window opened to turn on the light. Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless. + Bit 6: Reserve. + Bit 7: Reserve. + + + + + Customer function switch, using bit control. + Bit 0: Reserve. + Bit 1: Enable sending motion OFF report (0:Disable, 1:Enable). + Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00. + Bit 2: Enable PIR super sensitivity mode (0:Disable, 1:Enable). + Bit 3: Reserve. + Bit 4: Notification Type (0: Notification Report, 1: Sensor Binary Report). + Bit 5: Disable Multi CC in auto report (1:Disable, 0:Enable). + Bit 6: Disable to report battery state when the device triggered (1:Disable, 0:Enable) + Bit 7: Reserve. + ozw recommended setting: 00010110 : 22 + + + + + In the normal mode, after the PIR motion detected, setting the re-detect time, 8 seconds per tick, default tick is 3 (24 seconds). + Setting the suitable value to prevent received the trigger signal too frequency. Also can save the battery energy. + Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not start detecting. + + + + + After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. + 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. + + + + + The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function. + + + + + + + + + + + + + + diff --git a/openzwave/philio/psr03-1b.xml b/openzwave/philio/psr03-1b.xml new file mode 100644 index 00000000..f8b95e5d --- /dev/null +++ b/openzwave/philio/psr03-1b.xml @@ -0,0 +1,121 @@ + + + http://www.openzwave.com/device-database/013C:001D:0008 + images/philio/psr03-1b.png + https://products.z-wavealliance.org/products/1176/ + 1. Have Z-Wave ™ Controller entered remove mode. +2. Hold down the central key, then press the top-right +key three times within 1.5 seconds to enter the +remove mode. +Node ID has been excluded. + PSR03 + Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Hold down the central key, then press the top-right key four times within 1.5 seconds and do not release the top-right key in the 4 th pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the keys. If successful, the LED will light ON one second. Otherwise, the LED will flash once. +3. IDs are remove and all settings will reset to factory +default. + Remote + CEPT (Europe) + The Remote PSR03 is a simple control can control AV device through Z-Wave-to-IR extender, and it can also controls 8 lighting groups ON/OFF via basic set, based on Z-Wave™ technology. +It is a Z-Wave™ plus product, it supports the security, OTA... Those newest features of the Z-Wave™ technology. Z-Wave™ is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. + After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user want to wake-up the device immediately, please press the button once. The device will wake-up 10 seconds. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1176/PSR03_Manual.pdf + 1. Have Z-Wave TM Controller entered add mode. +2. Hold down the central key, then press the top-right key three times within 1.5 seconds to enter the add mode. +3. After add successful, the device will wake to receive the setting command from Z-Wave ™ Controller about 20 seconds. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1176/xml + + + + + + + Setting the BASIC command value to turn on the light. + The 0xFF(-1) means turn on the light. + For dimmer equipment 1 to 99 means the light strength. + 0 means turn off the light. + + + + + Customer function switch, using bit control. + + + + + + + The interval time for auto report the battery level. + 0 means turn off auto report battery. + Each tick means 30 minutes. + The default value is 12(6 hours). + + + + + Setting the BASIC command value to turn on the light in the association group 2. + 0 means using the value of configuration 2 to set. + + + + + Setting the BASIC command value to turn on the light in the association group 3. + 0 means using the value of configuration 2 to set. + + + + + Setting the BASIC command value to turn on the light in the association group 4. + 0 means using the value of configuration 2 to set. + + + + + Setting the BASIC command value to turn on the light in the association group 5. + 0 means using the value of configuration 2 to set. + + + + + Setting the BASIC command value to turn on the light in the association group 6. + 0 means using the value of configuration 2 to set. + + + + + Setting the BASIC command value to turn on the light in the association group 7. + 0 means using the value of configuration 2 to set. + + + + + Setting the BASIC command value to turn on the light in the association group 8. + 0 means using the value of configuration 2 to set. + + + + + Setting the BASIC command value to turn on the light in the association group 9. + 0 means using the value of configuration 2 to set. + + + + + + + + + + + + + + + + + + diff --git a/openzwave/philio/psr04.xml b/openzwave/philio/psr04.xml new file mode 100644 index 00000000..c1068fb0 --- /dev/null +++ b/openzwave/philio/psr04.xml @@ -0,0 +1,85 @@ + + + http://www.openzwave.com/device-database/013C:0022:0009 + images/philio/psr04.png + https://products.z-wavealliance.org/products/2573/ + 1. Have Z-Wave™ Controller entered inclusion mode. +2. Rotate to area A and then press button three times within 1.5 seconds to enter the inclusion mode. +3. After add successful, the device will wake to receive the setting command from Z-Wave™ Controller about 20 seconds. + 1. Have Z-Wave™ Controller entered exclusion mode. +2. Rotate to area A and then press button three times within 1.5 seconds to enter the exclusion mode. Node ID has been removed. + After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 20 seconds for receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user wants to wake-up the device immediately, please rotate to area A and then press the button once. The device will wake-up 10 seconds. + This device is a multiple functions button switch. It is able to +switch the appliances on/off or adjust the percentage of dimmer. +It can also work as a timer. The well designed wall bracket and +magnetic back let the switch can be fixed on the wall. This product +can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. + PSR04 + Smart Color Button + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2573/PSR04_manual.pdf + Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Rotate to area A and then press button four times within 1.5 seconds and do not release the button in the 4 th pressed, and the red LED will light ON. +2. After the red LED goes out, release the button within 2 seconds. +3. IDs are removed and all settings will reset to factory default. + CEPT (Europe) / Brazil + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1300/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1448/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2573/xml + + + + + + + Control the value represented by the left-side in area D. + E.g. Setting this configuration + to 15 means range of Command Basic Set value start from 15 + + + + + Control the value represented by the right-side in area D. + E.g. Setting this configuration + to 15 means range of Command Basic Set value start from 15 + + + + + The interval time for auto reporting + the Battery level. 0 means turn off auto report battery. + The default value is 12. + + + + + Bit 0: Dimmer setting method. + 0 : Auto send Command Basic Set after rotating. + 1 : Send Command Basic Set by touching key after rotating + Bit 1: Disable buzzer in timer mode. + 0: Enable. + 1: Disable. + + + + + Send Central Scene Holding when the button is held. + + + + + + + + + true + + + + + + + + + + diff --git a/openzwave/philio/pst02-1c.xml b/openzwave/philio/pst02-1c.xml new file mode 100644 index 00000000..86550dbf --- /dev/null +++ b/openzwave/philio/pst02-1c.xml @@ -0,0 +1,154 @@ + + + http://www.openzwave.com/device-database/013C:000E:0002 + images/philio/pst02-1c.png + https://products.z-wavealliance.org/products/2872/ + The slim multisensor PST02-1C has door/window, temperature and illumination, 3 sensors function in one,based on Z-Wave technology +It is the Z-WaveTM plus product, it support the security, OTA... Those +newest features of the Z-WaveTM technology. Z-WaveTM is a wireless +communication protocol designed for home automation, specifically to +remotely control applications in residential and light commercial +environments. The technology uses a low-power RF radio embedded or +retrofitted into home electronics devices and systems, such as lighting, +home access control, entertainment systems and household appliances. + Notice: Use this procedure only in the event +that the primary controller is lost or otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key on the 4th press, the LED lite will ON. +2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. +Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to factory default. + PST02-5C + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2872/PST02_UserManual.pdf + After the device adding to the network, it will wake-up once per day in +default. When it wakes-up it will broadcast the “Wake Up Notification” +message to the network, and wake-up 10 seconds to receive the +setting commands. +The wake-up interval minimum setting is 30 minutes, and maximum +setting is 120 hours. And the interval step is 30 minutes. +If the user want to wake-up the device immediately, please remove the +front cover, and press the tamper key once. The device will wake-up 10 +seconds. + 1. Have Z-WaveTM Controller enter inclusion mode. +2. Pressing tamper key three times within 1.5 seconds +will enter the inclusion mode. +3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller, about 20 seconds + Датчик открытия (Door sensor) + CEPT (Europe) / Russia / Russia + 1. Have Z-WaveTM Controller enter exclusion mode. +2. Pressing tamper key three times within 1.5 seconds will enter the exclusion mode. +Node ID has been excluded. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1092/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2839/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2872/xml + + + + + + + Setting the BASIC command value to turn on the light. The 0xFF (-1) means turn on the light. + For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. + + + + + Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower than + the threshold, the device will turn on the light. + 0 means turn off illumination detected function and never turn on the light. + 1 means darkest. + 99 means brightest. + 100 means turn off illumination detected function. And always turn on the light. + * Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. + + + + + Bit 0: Reserved + Bit 1: Reserved + Bit 2: Disable the door/window function (1: Disable, 0: Enable). + Bit 3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius. + Bit 4: Disable the illumination report after event triggered (1: Disable, 0: Enable). + Bit 5: Disable the temperature report after event triggered (1: Disable, 0: Enable). + + + + + Multi-Sensor Function switch. Using bit to control. + Bit 0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2 (1: Disable, 0: Enable). + Bit 1: Reserved always 1 + Bit 2: Reserved always 1 + Bit 3: Reserved + Bit 4: Disable delay 5 seconds to turn off the light, when door/window closed. + Bit 5: Disable auto turn off the light, after door/window opened to turn on the light. Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless. + Bit 6: Enable temperature monitoring. When this bit enabled the temperature changed 3 degree Fahrenheit. It will report. And also temp above 140 it will report every 64 seconds. + + + + + Customer function switch, using bit control. + Bit 0: Reserve. + Bit 1: Enable sending motion OFF report (0:Disable, 1:Enable). + Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00. + Bit 2: Enable PIR super sensitivity mode (0:Disable, 1:Enable). + Bit 3: Disable send out BASIC OFF after door closed (1:Disable, 0:Enable). + Bit 4: Notification Type (0: Notification Report, 1: Sensor Binary Report). + Bit 5: Disable Multi CC in auto report (1:Disable, 0:Enable). + Bit 6: Disable to report battery state when the device triggered (1:Disable, 0:Enable) + Bit 7: Reserve. + ozw recommended setting: 00010110 : 22 + + + + + After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. + 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. + + + + + The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function. + + + + + The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the "Temperature Report" section. + + + + + The illumination differential to report.0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the "Illumination Report" section. + + + + + + + + + + + + + + diff --git a/openzwave/philio/pst02-b.xml b/openzwave/philio/pst02-b.xml new file mode 100644 index 00000000..2a2d81ae --- /dev/null +++ b/openzwave/philio/pst02-b.xml @@ -0,0 +1,181 @@ + + + http://www.openzwave.com/device-database/013C:000D:0002 + images/philio/pst02-b.png + https://products.z-wavealliance.org/products/2860/ + There are two tamper keys in the device, one is in the back side, +another is in the front side. Both of them can add, remove or reset from Z-WaveTM network. +1. Have Z-WaveTM Controller entered inclusion mode. +2. Pressing tamper key three times within 1.5 seconds +to enter the inclusion mode. +3. After add successful, the device will wake to +receive the setting command from Z-WaveTM +Controller about 20 seconds + + PST02-5B + 1. Pressing tamper key four times within 1.5 seconds +and do not release the tamper key in the 4th +pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that +within 2 seconds, release the tamper key. If +successful, the LED will light ON one second. +Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to +factory default. + +*Please use this procedure only when the network primary controller is missing or otherwise inoperable. + After the device adding to the network, it will wake-up once per day in +default. When it wake-up it will broadcast the “Wake Up Notification” +message to the network, and wake-up 10 seconds for receive the +setting commands. +The wake-up interval minimum setting is 30 minutes, and maximum +setting is 120 hours. And the interval step is 30 minutes. +If the user want to wake-up the device immediately, please remove the +front cover,and press the tamper key once. The device will wake-up 10 +seconds. + Датчик движения (Motion Sensor) + The slim multisensorPST02-5B has PIR, temperature and illumination, 3 sensors function in one,based on Z-Wave technology +It is the Z-WaveTM plus product, it support the security, OTA... Those +newest features of the Z-WaveTM technology. Z-WaveTM is a wireless +communication protocol designed for home automation, specifically to +remotely control applications in residential and light commercial +environments. The technology uses a low-power RF radio embedded or +retrofitted into home electronics devices and systems, such as lighting, +home access control, entertainment systems and household appliances. + There are two tamper keys in the device, one is in the back side, +another is in the front side. Both of them can add, remove or reset from Z-WaveTM network. +1. Have Z-WaveTM Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds +to enter the exclusion mode. +Node ID has been excluded. + CEPT (Europe) / Russia / Russia + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2860/PST02_UserManual.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1090/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2833/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2860/xml + + + + + + + Setting the BASIC command value to turn on the light. The 0xFF (-1) means turn on the light. + For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. + + + + + PIR sensitivity settings. + 0 means disable the PIR motion. + 1 means the lowest sensitivity, + 99 means the highest sensitivity. + High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency. + + + + + Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower than + the threshold, the device will turn on the light. + 0 means turn off illumination detected function and never turn on the light. + 1 means darkest. + 99 means brightest. + 100 means turn off illumination detected function. And always turn on the light. + * Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. + + + + + Bit 0: Reserve. + Bit 1: 1 means enable test mode, 0 means disable normal mode. Notice: This bit only effect by the DIP Switch setting to program mode. + Bit 2: Set to 1. + Bit 3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius. + Bit 4: Disable the illumination report after event triggered (1: Disable, 0: Enable). + Bit 5: Disable the temperature report after event triggered (1: Disable, 0: Enable). + Bit 6: Reserve. + Bit 7: Disable the back key release into test mode (1: Disable, 0: Enable). + + + + + Multi-Sensor Function switch. Using bit to control. + Bit 0: Set to 1. + Bit 1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2 (1: Disable, 0: Enable). + Bit 2: Set to 1. + Bit 3: Reserve. + Bit 4: Reserve. + Bit 5: Reserve. + Bit 6: Reserve. + Bit 7: Reserve. + + + + + Customer function switch, using bit control. + Bit 0: Reserve. + Bit 1: Enable sending motion OFF report (0:Disable, 1:Enable). + Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00. + Bit 2: Enable PIR super sensitivity mode (0:Disable, 1:Enable). + Bit 3: Reserve. + Bit 4: Notification Type (0: Notification Report, 1: Sensor Binary Report). + Bit 5: Disable Multi CC in auto report (1:Disable, 0:Enable). + Bit 6: Disable to report battery state when the device triggered (1:Disable, 0:Enable) + Bit 7: Reserve. + ozw recommended setting: 00010110 : 22 + + + + + In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds). + Setting the suitable value to prevent received the trigger signal too frequency. Also can save the battery energy. + Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not start detecting. + + + + + After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. + 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. + + + + + The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function. + + + + + The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the "Temperature Report" section. + + + + + The illumination differential to report.0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the "Illumination Report" section. + + + + + + + + + + + + + + diff --git a/openzwave/philio/pst02.xml b/openzwave/philio/pst02.xml new file mode 100644 index 00000000..a3659761 --- /dev/null +++ b/openzwave/philio/pst02.xml @@ -0,0 +1,173 @@ + + + http://www.openzwave.com/device-database/013C:000C:0002 + images/philio/pst02.png + https://products.z-wavealliance.org/products/2568/ + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To remove the device from a Z-Wave network: +1. Have Z-Wave Controller entered exclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. +Node ID has been excluded. + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +Press any key once, the device will awake 10 seconds. + The slim multisensor PST02 has PIR, door/window, temperature and illumination, 4 sensors function in one,based on Z-Wave technology. + Slim Multisensor + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To add into a Z-Wave network: +1. Have Z-Wave Controller entered inclusion mode. +2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode. +3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2568/PST02_Manual.pdf + CEPT (Europe) / Australia / New Zealand + There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network. +To reset the device: +Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON. +2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. +3. IDs are excluded and all settings will reset to factory default. + PST02-A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1087/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1449/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2433/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2434/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2568/xml + Fix Philio door sensors #1898 + + + + + + + Setting the BASIC command value to turn on the light. The 0xFF (-1) means turn on the light. + For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. + + + + + PIR sensitivity settings. + 0 means disable the PIR motion. + 1 means the lowest sensitivity, + 99 means the highest sensitivity. + High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency. + + + + + Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower than + the threshold, the device will turn on the light. + 0 means turn off illumination detected function and never turn on the light. + 1 means darkest. + 99 means brightest. + 100 means turn off illumination detected function. And always turn on the light. + * Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. + + + + + Bit 0: Reserve. + Bit 1: 1 means enable test mode, 0 means disable normal mode. Notice: This bit only effect by the DIP Switch setting to program mode. + Bit 2: Disable the door/window function (1: Disable, 0: Enable). + Bit 3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius. + Bit 4: Disable the illumination report after event triggered (1: Disable, 0: Enable). + Bit 5: Disable the temperature report after event triggered (1: Disable, 0: Enable). + Bit 6: Reserve. + Bit 7: Disable the back key release into test mode (1: Disable, 0: Enable). + + + + + Multi-Sensor Function switch. Using bit to control. + Bit 0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2 (1: Disable, 0: Enable). + Bit 1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2 (1: Disable, 0: Enable). + Bit 2: Disable magnetic integrate PIR to turn ON the light the nodes in the association group 2 (1: Disable, 0: Enable) (Default is Disable). + Bit 3: When Bit 2 is 0 (Enable), Are the device and the lighting in the same room? 0: In the same room (Default), 1: In the different room. Notice: If this bit is 1, it is recommended also set the Bit1 to 1, cause the PIR triggered, doesn't mean the people in that room. + Bit 4: Disable delay 5 seconds to turn off the light, when door/window closed. + Bit 5: Disable auto turn off the light, after door/window opened to turn on the light. Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless. + Bit 6: Reserve. + Bit 7: Reserve. + + + + + Customer function switch, using bit control. + Bit 0: Reserve. + Bit 1: Enable sending motion OFF report (0:Disable, 1:Enable). + Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00. + Bit 2: Enable PIR super sensitivity mode (0:Disable, 1:Enable). + Bit 3: Disable send out BASIC OFF after door closed (1:Disable, 0:Enable). + Bit 4: Notification Type (0: Notification Report, 1: Sensor Binary Report). + Bit 5: Disable Multi CC in auto report (1:Disable, 0:Enable). + Bit 6: Disable to report battery state when the device triggered (1:Disable, 0:Enable) + Bit 7: Reserve. + ozw recommended setting: 00010110 : 22 + + + + + In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds). + Setting the suitable value to prevent received the trigger signal too frequency. Also can save the battery energy. + Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not start detecting. + + + + + After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. + 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. + + + + + The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20. + + + + + The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function. + + + + + The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the "Temperature Report" section. + + + + + The illumination differential to report.0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the "Illumination Report" section. + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/polycontrol/doorlock.xml b/openzwave/polycontrol/doorlock.xml new file mode 100644 index 00000000..092f6973 --- /dev/null +++ b/openzwave/polycontrol/doorlock.xml @@ -0,0 +1,116 @@ + + + http://www.openzwave.com/device-database/010E:0002:0008 + images/polycontrol/doorlock.png + https://products.z-wavealliance.org/products/1855/ + Danalock V2 BTZJ + To remove or exclude the danalock into a Z-Wave network +Set the controller in exclusion mode +Touch the User Button until you hear two beeps. + To add or include the danalock into a Z-Wave network +Set the controller in inclusion mode +Touch the User Button until you hear two beeps. + + The danalock can be set to factory settings by holding the User Button for ten beeps. Please use this procedure only when the primary controller is missing or otherwise inoperable. + Danalock V2 BTZJ + U.S. / Canada / Mexico / CEPT (Europe) / U.S. / Canada / Mexico / U.S. / Canada / Mexico / U.S. / Canada / Mexico / Japan + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1855/Danalock_V2_Product_manual_Z_Wave_V_1.0.4.pdf + Z-Wave Controlled door lock with keypad, and Bluetooth Smart. +Operated by Z-Wave. +Connect Danalock to your Z-Wave gateway - Danalock interfaces with your existing Z-Wave network through the Danalock smartphone app. +Operate Danalock remotely by accessing your Z-Wave network from anywhere in the world with internet access. + + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1238/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1251/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1532/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1764/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1769/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1855/xml + + + + + + + + true + + + + + 0=The motor goes clockwise when unlatched; 1= The motor goes counterclockwise when unlatched + + + + + Speed (Torque) + + + + + + + + 0=Stepper motor mode wave drive (Power Saving); 1=Stepper motor mode full drive(Normal) + + + + + + Factor 10 turn degree( 1 = degrees, 9 = 90 degres, etc. ) + + + How many seconds from the lock has been unlatched to it automatically close again. If 0 then it's disabled + + + Disable or enable the beep sound from latch or unlatch operations( + + + + + Set the type of battery that powers the device. This affect the returned battery state. + + + + + When the battery level is equal to, or under this value, the device will notify with a beep sound after latch or unlatch + + + Used if the lock is using a optional rotation sensor. Latch and Go on will turn automatically when manual turn is detected. + + + + + + 0 = Disabled. + 1-15 Seconds to brake. + When used the lock will brake for x amount of seconds and then turn 75 degrees back. + Made for special doors without door lever.(Only when unlatching). + + + + Used if the lock is using an optional rotation sensor. + When async is enabled the lock will auto calibrate if already unlatched and asked to Unlatch again (used for special door locks where the key turn is asynced from the inside nob.) + + + + + + + 0 = Simple supported by all controllers that support door locks. + 1 = Advanced, more specific reports through notification Command Class. + 2 = No Door lock operation reports are sent unsolicited. + + + + + + + + + + + + diff --git a/openzwave/polycontrol/doorlockv3.xml b/openzwave/polycontrol/doorlockv3.xml new file mode 100644 index 00000000..e07794d0 --- /dev/null +++ b/openzwave/polycontrol/doorlockv3.xml @@ -0,0 +1,90 @@ + + + http://www.openzwave.com/device-database/010E:0001:0009 + images/polycontrol/doorlockv3.png + https://products.z-wavealliance.org/products/3340/ + Danalock V3-BTZU-IL + 1. Set the controller in inclusion mode +2. Push the switch once. +3. Wait 5 seconds. + 1. Set the controller in exclusion mode +2. Push the switch once. +3. Wait 5 seconds. + Danalock V3-BTZU-IL + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3340/Danalock_V3_Product_manual_Z_Wave_V_0.9.4.pdf + The Danalock can be set to factory settings by pushing the switch ten times. Please use this procedure only when the primary controller is missing or otherwise inoperable. + CEPT (Europe) / U.S. / Canada / Mexico / Australia / New Zealand / Japan / Australia / New Zealand / CEPT (Europe) / U.S. / Canada / Mexico / Australia / New Zealand / Japan / Brazil / South Korea / Russia / Israel + Danalock supports: +- S0/S2 Z-Wave Security +- Bluetooth Smart +- Twist Assist +- Auto Lock +- Hold And Release +- Back To Back + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2556/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2601/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2629/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2630/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2644/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3217/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3295/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3311/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3312/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3337/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3338/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3339/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3340/xml + + + + + + + true + + + + + + + + + + + 0 Disable. + 1 to 2147483647 Enable, time in seconds. + + + + + + + + + + 0 Disable. + 1 to 2147483647 Enable, time in seconds. + + + + + + + + + + 0 Disable. + 1 to 2147483647 Enable, time in seconds. + + + + + + + + + diff --git a/openzwave/polycontrol/keypad.xml b/openzwave/polycontrol/keypad.xml new file mode 100644 index 00000000..eabbd76e --- /dev/null +++ b/openzwave/polycontrol/keypad.xml @@ -0,0 +1,30 @@ + + + + + + + true + + + + + + false + + + + + + false + + + + + + + + + + + diff --git a/openzwave/polycontrol/polylock.xml b/openzwave/polycontrol/polylock.xml new file mode 100644 index 00000000..2c45b43b --- /dev/null +++ b/openzwave/polycontrol/polylock.xml @@ -0,0 +1,37 @@ + + + + + + + true + + + + + 0=The motor goes clockwise when unlatched; 1= The motor goes counterclockwise when unlatched + + + Motor/relay run time LOCK in sec 1-15 + + + Motor/relay run time UNLOCK in sec 1-15 + + + Value 0-15/0=fastest 15=slowest + + + How the motor will turn according to torque and speed + + + + + + + + + + + + + diff --git a/openzwave/popp/004407.xml b/openzwave/popp/004407.xml new file mode 100644 index 00000000..77937773 --- /dev/null +++ b/openzwave/popp/004407.xml @@ -0,0 +1,50 @@ + + + http://www.openzwave.com/device-database/0154:0003:0004 + images/popp/004407.png + https://products.z-wavealliance.org/products/2086/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2086/004407_en.pdf + To do a factory reset press the button on the bottom of the device for at least 10 seconds. This procedure should only be used when the primary controller is inoperable. + Z-Wave CO Detector + The High-End Electro-Chemical Carbon Monoxide alarm head offers a 10 year sensor life and is powered via a 3V lithium battery that powers the Alarm head for the life of the alarm. The CO Sensor is monitored electronically and will report the following: +1. Alarm on Sensing Carbon Monoxide +2. Battery status reporting +3. Sensor Fault +4. Alarm removal from mounting plate +5. End of life to make sure it is replaced on time. +The device is a secure Z-Wave Plus device and can be used in one wireless Z-Wave network with other certified devices regardless of origin and brand. + + A single click on the button will wakeup the device. + Pressing the button 'Inclusion Button' for one second will include the device. If the button is pressed for at least 2 seconds the inclusion will be done without the Security Command Class. + CEPT (Europe) + A single click on the button will exclude the device. + POPE004407 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2086/xml + + + + + + + + Value of On-Command + + + + + Value of Off-Command + + + + + + + + + + + diff --git a/openzwave/popp/009105.xml b/openzwave/popp/009105.xml new file mode 100644 index 00000000..f6c7232a --- /dev/null +++ b/openzwave/popp/009105.xml @@ -0,0 +1,77 @@ + + + + + + + + Set LED indication mode + + + + + + + + If not zero, automatically switch device off after an user defined time. + 0 -> Disabled (default) + 1-65535 -> Enabled time in seconds. + + + + + + Defines how to interpret RF Off-Command. + Ignore - to switch on the light by motion detectors and switch it off after some amount of time; + in case of multiple motion detectors each would try to switch the light off that would break logics; + Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. + Button off click will still work (if button operations are not disabled). + + + + + + + + + Defines if the switch should restore switch state to the last prior to device power off (power cycle). + + + + + + + Specify the consumption of the load in Watts, for the calculation of power. + 0 -> Disabled (default) + 1 - 3500 -> Watts + + + + + Color for OFF state + + + + + + + + + Color for ON state + + + + + + + + + + + + + + + + + diff --git a/openzwave/popp/009303.xml b/openzwave/popp/009303.xml new file mode 100644 index 00000000..6f5043bb --- /dev/null +++ b/openzwave/popp/009303.xml @@ -0,0 +1,112 @@ + + + http://www.openzwave.com/device-database/0154:0101:0100 + images/popp/009303.png + https://products.z-wavealliance.org/products/2110/ + Place your primary controller in inclusion mode by following the manufacturer's instructions, then activate inclusion on the wall controller by pressing any one of the four buttons for one second. Inclusion mode is indicated by the red/green blinking of the LEDs until the timeout occurs after 10 seconds. + The Wall Scene Controller is a Z-Wave device that can both control other Z-Wave devices and activate scenes. Although it is controlling other devices, the Wall Controller cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration parameters: + +Control of groups of other Z-Wave devices using 'ON', 'OFF' and Dim commands. Activation of predefined scenes in Gateways or other Z-Wave devices. This device support secure communication when included by a controller that also supports secure communication. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2110/WallSceneControllerPopp.pdf + POPE009303 + (1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 2. + Re-Inclusion and Exclusion are performed by pushing button 1 in management mode. Pushing all four buttons for 5 sec. turns the device into management mode (indicated by blinking green LED). + CEPT (Europe) + Use this procedure only if the primary controller is missing or otherwise inoperable. +(1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 3, (3) keep button 4 pushed for 4 seconds. + Wall Scene Controller + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2110/xml + + + + + + + + In separate mode button 1 works with group A, button 3 with groups C. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C. + + + + + + In separate mode button 2 works with control group B, button 4 with control group D. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button B/D are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D. + + + + + + This parameter defines the command to be sent to devices of control group A when the related button is pressed + + + + + + + + + + + This parameter defines the command to be sent to devices of control group B when the related button is pressed + + + + + + + + + + + This parameter defines the command to be sent to devices of control group C when the related button is pressed + + + + + + + + + + + This parameter defines the command to be sent to devices of control group D when the related button is pressed + + + + + + + + + + + + + + + + + + + + If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/popp/009402.xml b/openzwave/popp/009402.xml new file mode 100644 index 00000000..272588a7 --- /dev/null +++ b/openzwave/popp/009402.xml @@ -0,0 +1,56 @@ + + + http://www.openzwave.com/device-database/0154:0004:0004 + images/popp/009402.png + https://products.z-wavealliance.org/products/2078/ + This products consists of a standard high-quality photo electric Smoke detector with a pluggable Z-Wave wireless interface module. The Smoke detector will also work as a stand alone product and is certified as '10 year Smoke Detector' The +smoke chamber of the detector has a stainless steel reel with antistatic plastic chamber. +A button allows on-device test of smoke chamber, electronics and battery. The device also offers a built-in self test and +an electronic smoke chamber test to avoid the use of test aerosol. A low battery warning will last for 30 days but full +function of the detector is guaranteed during this time. +The Z-Wave module allows to report the smoke and low battery alarm wirelessly to a central controller. The detector can +also be used as a wireless siren for alarm system or other applications. + To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5 +seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2078/009402Manual.pdf + Ei600ZW + To exclude the device start the inclusion on your controller and then hit the little button on the wireless module for 1 second + CEPT (Europe) + To include the device start the inclusion on your controller and then hit the little button on the wireless module for 1 second + 10 Year Smoke Detector and Siren + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2078/xml + + + + + + + + The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds. + + + The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. Please make sure this value is always smaller (shorter time) than parameter 1 that defines the whole sequence. + + + This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm occurs. + + + This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm is cleared. + + + + + + + + + + + diff --git a/openzwave/popp/009501.xml b/openzwave/popp/009501.xml new file mode 100644 index 00000000..2f3ed81d --- /dev/null +++ b/openzwave/popp/009501.xml @@ -0,0 +1,30 @@ + + + + + + + Status of the LED indicator during normal operation + + + + + Limit the operations that can be performed locally and/or over the Z-Wave network + + + + + + + + + + + + + + + + + diff --git a/openzwave/popp/012501.xml b/openzwave/popp/012501.xml new file mode 100644 index 00000000..1adab6ed --- /dev/null +++ b/openzwave/popp/012501.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/0154:0001:0005 + images/popp/012501.png + https://products.z-wavealliance.org/products/2147/ + Strike Lock Control + To do a factory reset press the Z-Wave button on the bottom of the device for at least 10 seconds. This procedure should only be used when the primary controller is missing or inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2147/POP_StrikeManual.pdf + An electric strike is an access control device used to lock and release doors. Electric strikes are installed in or on the doorframe and work in conjunction with mechanical door lock, on the principle of electronically controlling the rotation of the keeper allowing for door opening without manual retraction of the mechanical door lock. This product combines a 16 mm thick strike lock (that will fit into almost all door formats) with a Z-Wave plus empowered wireless control. The lock mechanics and the Z-Wave control are operated by a 9V block battery or an external 8-12V AC / 8-24V DC transformer. The Z-Wave control accepts commands to open or close the strike. Depending on a configuration parameter the door will be looked automatically after a certain time even if no ‘close’ command was sent. The device can be used standalone and within every conventional Intercom system controlling strike locks. + CEPT (Europe) + 012501 + Pressing the Z-Wave button for one second includes the device. It is not allowed to operate the device in a non-secure environment. This means that the including controller must support Secure Command Class. + A single click on the button will exclude the device. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2147/xml + + + + + + + + 0: No automated close after command open. + 1 - 127: Close again after x seconds (Default 3) + + + + 0 - 99 (Default 0) + + + 0 - 99 (Default 99) + + + + + + + + + + diff --git a/openzwave/popp/123580.xml b/openzwave/popp/123580.xml new file mode 100644 index 00000000..e5740087 --- /dev/null +++ b/openzwave/popp/123580.xml @@ -0,0 +1,105 @@ + + + + + + + + + Set LED indication mode + + + + + + + + If not zero, automatically switch off after a user defined time. Unit: Sec, Min: 0, Max: 65535, Default: 0 + + + + Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled). + + + + + + + + Defines if the dimmer shall ignore start level in Start Level Change command despite it is specified or not + + + + + + Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserve bulb life. 0=Instantly, 1-255 in 10ms units (Default 30) + + + + + Time to dim on button holds and Start Level Change command (if it has no duration specified). Unit in Seconds 1-255 (Default 3) + + + + Defines the dim level on command 'ON'. On default he dimmer restores last dim level. This parameter allows configuring the maximum level on second On command (if already On) or to always switch on to maximum level. + + + + + + + Time to dim on double click Off button for Baby-Dim function. This function works only if the load is operated by single press and hold button action. If enabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands. Unit in minutes 1-99 (0=Disable(Default) + + + + Target level on which to stop while executing Baby Dimming. Can be 0 to completely switch off the light. Unit in % 0-255 (0=Default) + + + + Typical time used to differentiate click, hold, double and triple clicks. in 10ms units (Default 50) + + + + + Minimal level should be greater than maximal. 1-95 Level limit (Default 1) + + + + Maximal level should be greater than minimal. 0=Work as switch: use off and maximal level 10-99 Level limit (Default 99) + + + + Defines how the dimmer hall react on a simple ON Command. 0-99 0=Use previous light level (Default), 1 . 99 Define light level in % + + + + + NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 1. For other bulbs use default value. 5-60 (Default 28) + + + + NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 40. For other bulbs use default value. 5-60 (Default 28) + + + + NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 20. For other bulbs use default value. 3-20 (Default 10) + + + + NB: Do not touch these settings if you are not sure what they mean! (Default 0) + + + + + + + + + + + + + + + + diff --git a/openzwave/popp/123601.xml b/openzwave/popp/123601.xml new file mode 100644 index 00000000..70d100d7 --- /dev/null +++ b/openzwave/popp/123601.xml @@ -0,0 +1,45 @@ + + + + + + + + + Set LED indication mode + + + + + + + + If not zero, automatically switch off after a user defined time. Unit: Sec, Min: 0, Max: 65535, Default: 0 + + + + Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled). + + + + + + + + Defines if the switch should restore switch state to the last state prior to device power off (power cycle). + + + + + + + + + + + + + + + + diff --git a/openzwave/popp/123658.xml b/openzwave/popp/123658.xml new file mode 100644 index 00000000..1b04deb7 --- /dev/null +++ b/openzwave/popp/123658.xml @@ -0,0 +1,34 @@ + + + + + + + + + If the setting is configured for 1 hour(set value=720), the device will report its instant power consumption every 1 hour to Z_Wave controller. Unit: 5 secs, Min: 1, Max: 32767, Default: 720 + + + + If the setting is configured for 1 hour(set value=6), the device will report its Accumulated power consumption (KW/h) every hour to Z_Wave controller. Unit: 10 min, Min: 1, Max: 32767, Default: 6 + + + + This is a warning when the wattage of load over the present threshold value, if the load wattage exceeds the setting value the device will send a warning alarm command to the controller. Min: 10, Max: 3000, Default: 3000 + + + + 0 for Switch Off, 1 for Last Switch State (Default), 2 for Switch On + + + + + + + + + + + + + diff --git a/openzwave/popp/700045.xml b/openzwave/popp/700045.xml new file mode 100644 index 00000000..83308803 --- /dev/null +++ b/openzwave/popp/700045.xml @@ -0,0 +1,75 @@ + + + http://www.openzwave.com/device-database/0154:0002:0005 + images/popp/700045.png + https://products.z-wavealliance.org/products/2481/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2481/POPE700045Manual.pdf + Turn into Management Mode (remove cover), hit button 2 and confirm with * (Star Key) + This keypad is a security enabled Z-Wave Plus product. An security enabled Z-Wave controller must be used to fully utilize this product. The keypad allows securely controlling devices - such as door locks - and trigger actions in a gateway – such as arm/disarm alarm system– based on the entry of certain key codes. Additionally a bell key allows emulating a doorbell by operating e.g. a chimney or a light or both. + +The device can operate in two different modes. The mode is chosen the way the device is included into a Z-Wave network: +(a) Stand Alone Mode. In this case the keypad acts as the primary network controller and will include other devices such as e.g. a strike lock control or a chimney. No other central controller is needed. The management of user codes is done using the keypad itself. +(b) Network Mode. The keypad is included as additional device into an exiting network. In Z-Wave terms it will then act as secondary controller. It will send commands to a central controller and is managed by this controller. In this mode the device can still directly control door locks but it can also be used to trigger scenes in a central controller. +The device is protected by a tamper switch sending out an alarm message when the enclosure is opened. + + CEPT (Europe) + Hit the RING button + Z-Wave Keypad + Turn into Management Mode (remove cover), hit button 5 and keep button * (star key) pushed for 10 seconds. This procedure should only be used when the primary controller is inoperable. + Turn into Management Mode (remove cover), hit button 1 and confirm with * (Star Key) + 700045 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2481/xml + + + + + + + + After this time a CLOSE command is sent to the controlled door lock. + On default no CLOSE command is sent assuming that the strike lock has its own timeout set. + Default Value: 0 + + + + + After this time the Door Bell will receive an OF command regardless of the actual button is pressed or not. + Default Value: 3 + + + + + This value is sent into Association Group 3 when the door bell button is pressed. + Default Value: 255 + + + + + This value is sent into Association Group 3 when the door bell button is released or the timeout has reached. + Default Value: 0 + + + + This parameter defines if different user codes shall cause individual or similar scene ID sent to the main controller. + + + + + Buzzer Confirmation + + + + + + + + + + + + + diff --git a/openzwave/popp/700168.xml b/openzwave/popp/700168.xml new file mode 100644 index 00000000..4ba38e29 --- /dev/null +++ b/openzwave/popp/700168.xml @@ -0,0 +1,79 @@ + + + http://www.openzwave.com/device-database/0154:0011:0004 + images/popp/700168.png + https://products.z-wavealliance.org/products/2418/ + Push the button inside the device for at least 10 seconds. +Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + Push the Z-Wave button one time. You find the Z-Wave button by removing the electronics module from the base. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2418/POPE700168_Manual.pdf + This device measures the rain level on a certain position. The device is IP55 rated and can be used outside the home in the garden or on any other place exposed to rain. The device has a funnel on the top-side that will collect the rain on a certain diameter. The internal mechanics and electronics counts the rain level and will report it every about 4 minutes if and only if there is rain. The device also monitors a heavy rain condition (10 l/sqm within 5 minutes) and will send out alarm messages when detected. + CEPT (Europe) + Z-Wave Rain Sensor + Push the Z-Wave button one time. You find the Z-Wave button by removing the electronics module from the base. + 700168 + Push the Z-Wave button one time. You find the Z-Wave button by removing the electronics module from the base. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2418/xml + + + + + + + + Ths values shows the total count of rain from the moment of inclusion in mm water level. By writing this value this counter can be reset. + Default Value: 0 + + + + + This BASIC Set Command value is sent out into Association Group 2 when the device detects start of rain. + Default Value: 99 + + + + + This BASIC Set Command value is sent out into Association Group 2 when the device detects stop of rain. + Default Value: 0 + + + + + This multiplier allows to adapt the display to certain controllers not being able to handle very low numbers. + Default Value: 1 + + + + + + + + + This threshold defines when a heavy rain condition is hit. In most countries this is defined as > 15 mm rain per hour. + The default value however is to turn this function off. + Default Value: 255 + + + + + This BASIC Set Command value is sent out into Association Group 3 when the device detects start of heavy rain. + Default Value: 99 + + + + + This BASIC Set Command value is sent out into Association Group 3 when the device detects stop of heavy rain. + Default Value: 0 + + + + + + + + + + + + diff --git a/openzwave/popp/700342.xml b/openzwave/popp/700342.xml new file mode 100644 index 00000000..0d878d06 --- /dev/null +++ b/openzwave/popp/700342.xml @@ -0,0 +1,33 @@ + + + 10 Year Smoke Detector + This products consists of a standard high-quality photo electric Smoke detector with a pluggable Z-Wave wireless interface module. The Smoke detector will also work as a stand alone product and is certified as '10 year Smoke Detector' The smoke chamber of the detector has a stainless steel reel with antistatic plastic chamber. A button allows on-device test of smoke chamber, electronics and battery. The device also offers a built-in self test and an electronic smoke chamber test to avoid the use of test aerosol. A low battery warning will last for 30 days but full function of the detector is guaranteed during this time. The Z-Wave module allows to report the smoke and low battery alarm wirelessly to a central controller. + http://www.openzwave.com/device-database/0154:0004:000D + https://www.popp.eu/products/sensors/10-jahres-rauchmelder-700342/ + https://www.popp.eu/support/manuals/ + images/popp/009402.png + https://www.popp.eu/005107en + A double click on the Z-Wave button wakes up the device> + Secure Inclusion: Push the button for 3 seconds, Unsecure Inclusion: Push the button for 1 seconds + Push the button for 1 second + To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5 seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable. + + From the User Manual and the 009402.xml + + + + + This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm occurs. + + + This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm is cleared. + + + + + + + + + + diff --git a/openzwave/popp/700397.xml b/openzwave/popp/700397.xml new file mode 100644 index 00000000..34c42e8b --- /dev/null +++ b/openzwave/popp/700397.xml @@ -0,0 +1,133 @@ + + + http://www.openzwave.com/device-database/0154:000A:0003 + images/popp/700397.png + https://products.z-wavealliance.org/products/2842/ + The Wall Plug Switch Outdoor can be placed between a wall outlet for Schuko plugs (plug type F) and electric devices, plugged in by cord. It can switch all loads up to 3500 W. The plug switch is IP 44 rated and can therefore be used both in dry as well as humid environments in- and outdoor. +Switching is controlled by the local button or wirelessly. The use of the local button and the behavior oon wireless commands can be configured using configuration parameters. Whn detached from the control of local leads the button on the device can be used to trigger scenes in a central gateway. Single click and double click are distinguished. +The device is also measuring the mains voltage supply reporting mains voltage and mains frequency. Addtionally the powr consumption of the attached load is monitored as well. +All metering values an be requested from the central controller and will be reported unsolicited if configured. + Z-Wave Metering Plug Smart Start + POPE700397 + Tripple Click the button + CEPT (Europe) + Tripple Click the button + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2842/POPE700397_v2.pdf + This device allows reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable. Push and hold the button for 10 seconds. After 5 seconds the LED on the button will blink fast. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2842/xml + + + + + + + + Defines when the LED shall shine and how + + + + + + If not zero, automatically switch device off after an user defined time. + 0 -> Disabled (default) + 1-65535 -> Enabled time in seconds. + + + + + Defines how to interpret RF Off-Command. + Ignore - to switch on the light by motion detectors and switch it off after some amount of time; + in case of multiple motion detectors each would try to switch the light off that would break logic; + Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. + Button off click will still work (if button operations are not disabled). + + + + + + + + This parameter defines if the local button shall control (switch) the load or it is only used to send out scene control commands to the central controller. + + + + + Defines if the switch should restore switch state to the last prior to device power off (power cycle). + + + + + Defines the behavior of the LED when the load is switched off + + + + + + Defines the behavior of the LED when the load is switched on + + + + + + + Report the voltage when the voltage has changed by more then X * 1 V. + When disabled the device will report every 10 minutes regardless of current voltage. + 0 -> Disabled + 100 -> Default + 0 - 250 -> Volt + + + + + Report the current when the current has changed by more then X *0,01 A. + When disabled the device will report every 10 minutes regardless of current change. + 0 -> Disabled + 10 -> default + 0 - 255 -> * 0,01 A + + + + + Report the power when the power has changed by more then X Watt. + When disabled the device will report every 10 minutes regardless of power consumption change. + 0 -> Disabled + 50 -> Default + 1 - 255 -> Watts + + + + + When the power draw exceeds the value set in this parameter for a time set in parameter 28 the soft circuit breaker will disconnect the load. + 0 -> Disabled + 3600 -> Default + 1 - 3600 -> Watts + + + + Once the soft circuit breaker tipps and the load is disconnected the load will be automatically reconnected after X seconds. + When disabled the load must be repowered manually or with wireless command. + 0 -> Disabled (default) + 1 - 255 -> Seconds + + + + This delay time defines how fast the soft circuit breaker wil react when the threshold power is exceeded. + The power is cut off only if the power draw remains over the threshold level for the defines time. + 0 -> Disabled + 10 -> Default + 1 - 255 -> * 0,1 sec + + + + + + + + + + + diff --git a/openzwave/popp/700793.xml b/openzwave/popp/700793.xml new file mode 100644 index 00000000..3f3e82c7 --- /dev/null +++ b/openzwave/popp/700793.xml @@ -0,0 +1,22 @@ + + + + + + + Defines if the switch should restore switch state to the last prior to device power off (power cycle). + + + + + + + + + + + + diff --git a/openzwave/popp/701202.xml b/openzwave/popp/701202.xml new file mode 100644 index 00000000..0354cf20 --- /dev/null +++ b/openzwave/popp/701202.xml @@ -0,0 +1,118 @@ + + + Mold Detector + + This device measures the three air quality parameters temperature, humidity and dew point and reports them to a central controller. Beside this, the device can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. This can be used to establish control loops for temperature and humidity. The device wakes up every 15 minutes to measure the values and it will send unsolicited reports when values change, Additionally the device will report all values request on. + The mold detector is actively monitoring the danger of mold in a room based on the temperature and humidity and will issue alarm warnings when critical air conditions are met. Wireless Alarm and red and a green blinking LED will indicate a mold condition. This local LED warning function is also available when the device is not included in any Z-Wave network and works stand alone. + + http://www.openzwave.com/device-database/0154:0014:0004 + https://popp.eu/products/sensors/mold-detector-701202/ + https://popp.eu/support/ + images/popp/701202.png + https://manuals.zwave.eu/backend/make.php?lang=EN&sku=POPE701202&cert= + Press the tamper button on the side of the appliance once. + + 1. Open the housing. + 2. Remove the battery protection. + 3. Press the tamper button on the side of the appliance three times quickly. + + 1. Open the housing. + 2. Press the tamper button on the side of the appliance three times quickly. + + + Remove the cover, press the button for 5 seconds until it flashes green. Release the button and press the button again until the blinking stops. + + + https://products.z-wavealliance.org/products/3249?selectedFrequencyId=1 + CEPT (Europe) + 701202 + + + Initial configuration file, based on information from the vendor's and z-wavealliance.org websites, but with small linguistic changes and a few corrections. + + + + + + + + This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline. + If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 4, may still be active. + Default Value: 20 + + + + + This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline. + If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 4, may still be active. + Default value: 7 + + + + + + This parameter defines the time interval to send an unsolicited report. + If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active. + Default value: 43200 + + + + + This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2 + Default Value: 0 + + + + + This parameter defines a temperature. If the measured temperature drops below this watermark a BASIC command is sent into Association Group 3 + Default Value: 0 + + + + + This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark a BASIC command is sent into Association Group 4 + Default Value: 0 + + + + + This parameter defines a relative humidity. If the measured relative humidity drops below this relative humidity a BASIC command is sent into Association Group 5 + Default Value: 0 + + + + + This defines what BASIC command shall be sent out into association group 3 + Default Value: 255 + + + + + This defines what BASIC command shall be sent out into association group 2 + Default Value: 0 + + + + + This defines what BASIC command shall be sent out into association group 5 + Default Value: 255 + + + + + This defines what BASIC command shall be sent out into association group 4 + Default Value: 0 + + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/popp/dwt.xml b/openzwave/popp/dwt.xml new file mode 100644 index 00000000..79f41a5d --- /dev/null +++ b/openzwave/popp/dwt.xml @@ -0,0 +1,140 @@ + + + http://www.openzwave.com/device-database/0154:0007:0004 + images/popp/dwt.png + https://products.z-wavealliance.org/products/3345/ + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3345/DoorWindowSensor_POPE700892_UserManual.pdf + POPP Door/Window Sensor is a small window position sensor for your smart home, it monitors window and their exact opening position and lets your know when a window is tilted or completely opened. It also supports connecting external binary sensors through the dry binary contact of the Door/ Window sensor. + Tripple click the tamper switch + Window/Door Sensor with Tilt Detection + Tripple click the tamper switch + Once Cover is removed and tamper switch is tripped, push the tamper for 5 seconds until red LED blinks. Then release tamper and push it again for 5 seconds until LED blinks + POPE700892 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3345/xml + + + + + + + + Defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. There is always one input active only. The other sensor input the deactivated. + Default Value: Internal Magnet Sensor Used + + + + + + + Defines the polarity of the magnet sensor. + Default Value: Closed when Magnet in proximity + + + + + + + Defines when the red LED will indicate events. Disabling all indications may extend battery life. + Default Value: 7 (Bit 0, 1 and 2) + + Bit 0: No Indications + Bit 1: Open/Close Status Change + Bit 2: Wake Up + Bit 4: Device Tampering + + + + + Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch. + Default Value: Disabled + + + + + + + Defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2. + Default Value: Switch after Open and Close + + + + + + + + Defines which commands is sent to 2nd Association Group. + Default Value: On and Off + + + + + + + + This is the BASIC command value sent in case of an On event. + Default Value: 255 + Value Range: 0 - 99 and 255 + + + + + This is the BASIC command value sent in case of an Off event. + Default Value: 0 + Value Range: 0 - 99 and 255 + + + + + Off command is sent after a delay in seconds + Default Value: 0 + + + + + Off command is sent after a delay in seconds + Default Value: 0 + + + + + Time a tamper alarm is delayed in seconds. + Default Value: 0 + + + + + Defines if the alarm cancellation event is reported. + Default Value: Send Report + + + + + + + Enables/disables the central scene function. + Default Value: Disabled + + + + + + + Enables/disables tilt function. + Default Value: Enabled + + + + + + + + + + + + + + + diff --git a/openzwave/popp/smoke-detector.xml b/openzwave/popp/smoke-detector.xml new file mode 100644 index 00000000..6d7c9b4a --- /dev/null +++ b/openzwave/popp/smoke-detector.xml @@ -0,0 +1,63 @@ + + + http://www.openzwave.com/device-database/0154:0201:0100 + images/popp/smoke-detector.png + https://products.z-wavealliance.org/products/2111/ + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2111/POPE004001_en.pdf + This products consists of a standard photo electric Smoke detector with a pluggable Z-Wave wireless interface module. +The Smoke detector will also work as a stand alone product and is certified according to EN 14604. The +smoke chamber of the detector has a stainless steel reel with antistatic plastic chamber. +A button allows on-device test of smoke chamber, electronics and battery. The device also offers a built-in self test and +an electronic smoke chamber test to avoid the use of test aerosol. A low battery warning will last for 30 days but full +function of the detector is guaranteed during this time. +The Z-Wave module allows to report the smoke and low battery alarm wirelessly to a central controller. The detector can +also be used as a wireless siren for alarm system or other applications. The wireless module is operated by the 9V battery +of the smoke detector. An optional external power supply allows external powering the unit. +According to VdS 3515 (Smoke Detectors with Wireless Communication) this device will send alarm signals to all other +smoke detectors registered in association group 2 to turn on their siren. This function ensures that all smoke detectors +will issue noise if one of them detected a smoke. + To Exclude, hit the little button on the wireless module for 1 second + Smoke Detector and Siren + To Include, hit the little button on the wireless module for 1 second + To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5 +seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable. + POPE004001 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2111/xml + + + + + + + + The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds. + + + The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. + + + Value of On-Command + + + Value of Off-Command + + + This smoke detector can automatically inform other smoke detectors of same type about smoke alarms. They will then also turn on the siren. This function is a requirement of wireless networked smoke detectors. + + + + + This smoke detector can automatically inform other smoke detectors of same type about battery alarms. They will then also turn on the siren. This function is a requirement of wireless networked smoke detectors. + + + + + + + + + + + diff --git a/openzwave/popp/solar-siren.xml b/openzwave/popp/solar-siren.xml new file mode 100644 index 00000000..979952bc --- /dev/null +++ b/openzwave/popp/solar-siren.xml @@ -0,0 +1,59 @@ + + + http://www.openzwave.com/device-database/0154:0002:0004 + images/popp/solar-siren.png + https://products.z-wavealliance.org/products/2085/ + POPE005107 + Outdoor Solar Siren + 1. Open the case and turn on the power switch 2. Remove the metal mounting plate from the device. 3. Turn your controller into inclusion mode with a short single click on the internal inclusion button. + + This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable. + +To reset the device keep the inclusion button pushed for 10 seconds. After 5 seconds the LED starts flashing and after another 5 seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable. + This solar powered outdoor siren can be used without any additional power supply or batteries. It can be installed on any place on the outside of the house and can be controlled using Z-Wave. The device will issue a very loud sound (105 dBm) and in parallel some stroboscope light as well. The siren is self-protecting. Removing the main device from the mounting unit immediately starts the siren and also reports the tamper attempt to the Z-Wave central controller. All communication between the Z-Wave controller and the siren is encrypted and secured to protect against manipulation. Thanks to the large solar panel the siren can be mounted on nearly every place outside the house, with direct or indirect sun light. The siren is maintenance-free and water-proofed (IP56). The average solar energy of one day keeps the device alive for up to 50 days (without using the siren). Additionally an internal temperature sensor reports the temperature inside the siren’s enclosure. + CEPT (Europe) + 1. Open the case and turn on the power switch 2. Remove the metal mounting plate from the device. 3. Turn your controller into exclusion mode with a short single click on the internal inclusion button. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2085/005107_en.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2085/xml + + + + + + + + Sets the tamper triggering mode when removed from the holder + + + + + + Temperature correction. For positive value 10 = 1 C, for negative value x = 256 - (TC * 10). Example, if need shift -2.6C, value calculate: 256 - (2.6 * 10) = 230 Default: 0 + + + Threshold temperature to send unsolicited report. 10 = 1C + + + If the value is set, after N wake up number (measurement is every 4 minutes) the temperature report will be sent. By default it's 15 = every 1 hour + + + Siren only, flash only, flash + siren + + + + + + If the value is set, the siren will be switched off automatically after a defined alarm time. + 0: No auto off + + + + + + + + + + diff --git a/openzwave/popp/zweather.xml b/openzwave/popp/zweather.xml new file mode 100644 index 00000000..6366815b --- /dev/null +++ b/openzwave/popp/zweather.xml @@ -0,0 +1,54 @@ + + + http://www.openzwave.com/device-database/0154:0400:0100 + images/popp/zweather.png + https://products.z-wavealliance.org/products/2102/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2102/POPE005206_en.pdf + Push the button 3 times within 1.5 seconds. + Hold the button longer than 1.5 seconds and then release. +The LED blinks longer than when pressing the button once. +Z-Weather performs a factory reset and all configuration parameters are reset to their default values. Use this procedure only when the network primary controller is missing or otherwise inoperable. + + Z-Weather + POPE005206 + CEPT (Europe) + Push the button 3 times within 1.5 seconds. The LED blinks once indicating that Z-Weather is. Z-Weather sends a Z-Wave Wakeup-Notification if has been added to the network. If Z-Weather has not yet been added to the network, no action is performed. + Z-Weather is a multisensor device monitoring outside weather and environmental conditions. It continually measures the wind speed and can, for example, trigger closing of the awning and blinds if it is too windy. It also measures the amount of rotation, enabling calculation of the wind yield per day or per year. In addition, Z-Weather includes sensors for humidity, temperature, pressure and dew point, essentially providing the core sensors of a weather station. +Z-Weather is powered by a solar cell and stores energy on an internal capacitor, enabling continuous operation, even with no wind for a couple of days. It does not use any batteries and is completely maintenance free. Using the built-in solar cell it also measures the ambient light and the solar yield. This information can be used to turn on the outdoor light at dusk time and turn the light off in the morning. +Z-Weather‘s wind yield and solar yield metering can be used as a calculation base for planning a wind generator or a solar panel on the roof of a house. + + Push the button 3 times within 1.5 seconds. If the LED is not blinking after releasing the button, Z-Weather has not enough energy and must be charged for several hours in bright sunlight. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2102/xml + + + + + + + + Crossing this parameter on the rising edge, Z-Weather sends a basic set to the associated groups, serves the lifeline and sends a wake up notification. + Valid values: 0-30 m/s, where 0 means no notification on too much wind. + Default: 6 + + + + + Crossing this parameter from night to day, association group 3 is informed. + Crossing this parameter from day to night, association group 4 is informed. + Valid values: 0-100 %, where 0 means off. + Default: 37 (street lightning) + + + + + + + + + + + + + diff --git a/openzwave/prowell/zw-702.xml b/openzwave/prowell/zw-702.xml new file mode 100644 index 00000000..2dea6878 --- /dev/null +++ b/openzwave/prowell/zw-702.xml @@ -0,0 +1,18 @@ + + + http://www.openzwave.com/device-database/0163:0301:3001 + images/prowell/zw-702.png + https://products.z-wavealliance.org/products/995/ + CEPT (Europe) / U.S. / Canada / Mexico / CEPT (Europe) / CEPT (Europe) / U.S. / Canada / Mexico + Queenlock Z-Wave Mortise Lock + Use AES encryption to Lock/Unlock Door,have User Code management?Logging and schedule setting + ZW-708 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/942/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/943/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/985/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/986/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/995/xml + + + diff --git a/openzwave/q-light/q-light_puck.xml b/openzwave/q-light/q-light_puck.xml new file mode 100644 index 00000000..1a41a95a --- /dev/null +++ b/openzwave/q-light/q-light_puck.xml @@ -0,0 +1,151 @@ + + + + http://www.openzwave.com/device-database/0433:0005:0003 + images/q-light/q-light_puck.png + https://products.z-wavealliance.org/products/3774 + Puck + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3774/Instructions_Z-Wave_Puck_Norsk_A4.pdf + Z-Wave Puck dimmer by Q-light is a micro size in wall dimmer. +Features: +- 0-100% dimming range +- 2-180W LED load +- Compatible with any Z-Wave or Z-Wave Plus Controller +- There is memorized function at power off +- OverLoad protection +- Soft start function +- SmartStart +- Works with various types of switches – on/off, momentary, roller-blind, and etc +- This device is a security enable Z-Wave Plus product that is able to use encrypted Z-Wave Plus +messages to communicate to other security enable Z-Wave Plus products. + + +Removing (Exclusion): +Allowing to remove the Z-Wave device from existing Z-Wave network. + +1. Place the Z-Wave Puck within the direct range of your Z-Wave controller. +2. Identify switch S1/S2 (turns the light on) or the Internal button (located on the device’s housing). +3. Set the main controller in (security/non-security) add mode (see the controller’s manual). +4. Quickly, three times press switch S1 / S2 or Internal button. +5. Wait for the removing process to end. + + CEPT (Europe) + Q-light Zerodim Z-Wave + Resetting the Z-Wave Puck: + +1. Quickly, nine times press switch S1 / S2 or Internal button. +2. Wait for the resetting process to end, which is signaled with the LED indicator blinks 20 times. + +Device reset status: Turn on the light at maximum brightness. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable + + +Classic Learn Mode: + +1. Place the Z-Wave Puck within the direct range of your Z-Wave controller. +2. Identify switch S1/S2 (turns the light on) or the Internal button (located on the device’s housing). +3. Set the main controller in (security/non-security) add mode (see the controller’s manual). +4. Quickly, three times press switch S1 / S2 or Internal button. 5. Wait for the adding process to end. +6. Successful adding will be confirmed by the Z-Wave controller’s message. + + + Initial release + fix associations + + + + + + +Set the desired value from 1 to 98% for the minimum dim level that the dimmer is restricted to, the dimmer will not go lower than the value set here. + + + + +Set the desired value from 2 to 99% for the maximum dim level that the dimmer is restricted to, the dimmer will not go higher than the value set here. + + + + +This parameter defines the percentage value of dimming step during the automatic control. + + + + +This parameter defines the time of single dimming step set in parameter 3 during the automatic control. + + + + +This parameter defines the percentage value of dimming step during the manual control. + + + + +This parameter defines the time of single dimming step setin parameter 5 during the manual control. + + + + Set the desired value from 0 to 1 to turn on/off the memory function.Setting this value to 0 turns off the dimmer's Memory fucntion.Setting this value to 1 truns on the dimmer's Memory function. + + + + + +Choose between momentary, ON/OFF and roller blind switch. + +Available settings: +0 – momentary (Push) switch. +1 – ON/OFF switch. +2– roller blind switch-two switchs operate the device(S1 to brighter, S2 to dim + + + + + + + Set the desired value from 0 to 1 to turn on/off the memory function.Setting this value to 0 turns off the dimmer's Memory fucntion.Setting this value to 1 truns on the dimmer's Memory function. + + + + + +When you press S1 five times,the light is dimmed to the brightness set in Scene ID 3 . + +S1 Scene ID is set by this configuration. + +Note: The actual action of each SCENE ID are set by SCE-NE_ACTUATOR_CONF(0x26) command. + + + + +When you press S1 five times,the light is dimmed to the brightness set in Scene ID 5. + + +S2 Scene ID is set by this configuration. + +Note: The actual action of each SCENE ID are set by SCE-NE_ACTUATOR_CONF(0x26) command. + + + + This parameter allows to automatically switch off the device after specified time from switching on the light source. It may be useful when the Zerodim Z-Wave is installed in the stairway. + +Available settings: +0 - Function disabled. +1-32767 - time to turn off measured in seconds (1s-9.1h) + + + + + + + + + + + + + + + diff --git a/openzwave/q-light/q-light_zerodim.xml b/openzwave/q-light/q-light_zerodim.xml new file mode 100644 index 00000000..747c175b --- /dev/null +++ b/openzwave/q-light/q-light_zerodim.xml @@ -0,0 +1,120 @@ + + + + http://www.openzwave.com/device-database/0433:000D:0003 + images/q-light/q-light_zerodim.png + https://products.z-wavealliance.org/products/3775 + Zerodim + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3775/Instructions_ZerodimZwave_Norsk_A4.pdf + Zerodim Z-Wave by Q-light is a wireless smart home device. +Features: +- 0-99% dimming range +- 2-180W LED load +- Compatible with any Z-Wave or Z-Wave Plus Controller +- There is memorized function at power off +- OverLoad protection +- Soft start function +- SmartStart +- This device is a security enable Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enable Z-Wave Plus products. + + +1. Place the Zerodim Z-Wave within the direct range of your Z-Wave controller. +2. Identify switch rotary knob (turns the light on). +3. Set the main controller in (security/non-security) add mode (see the controller’s manual). +4. Quickly, three times press switch rotary knob. +5. Wait for the removing process to end. +6. Successful removing will be confirmed by the Z-Wave controller’s message. + + CEPT (Europe) + Q-light Zerodim Z-Wave + Resetting the Zerodim Z-Wave: +1. Quickly, nine times press switch rotary knob. +2. Wait for the resetting process to end, the lamp will be set to maximum brightness. + +Device reset statues: Turn on the light at maximum brightness. + + +Classic Learn Mode: +1. Place the Zerodim Z-Wave within the direct range of your Z-Wave controller. +2. Identify switch rotary knob (turns the light on). +3. Set the main controller in (security/non-security) add mode (see the controller’s manual). +4. Quickly, three times press switch rotary knob. +5. Wait for the adding process to end. +6. Successful adding will be confirmed by the Z-Wave controller’s message. + +SmartStart Learn Mode: +1. Scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. +2. No further action is required and the SmartStart product will be added automaticall within 10 minutes of being switched on in the network vicinity. +3. The QR Code and DSK are attached to the back of the product case, as shown below: + + + Initial release + fix associations + + + + + + +Set the desired value from 1 to 98% for the minimum dim level that the dimmer is restricted to, the dimmer will not go lower than the value set here. + + + + +Set the desired value from 2 to 99% for the maximum dim level that the dimmer is restricted to; the dimmer will not go higher than the value set here. + + + + +This parameter defines the percentage value of dimming step during the automatic control. + + + + +This parameter defines the time of single dimming step set in parameter 3 during the automatic control. + + + + +This parameter defines the percentage value of dimming step during the manual control. + + + + +This parameter defines the time of single dimming step setin parameter 5 during the manual control. + + + + Set the desired value from 0 to 1 to turn on/off the memory function.Setting this value to 0 turns off the dimmer's Memory fucntion.Setting this value to 1 truns on the dimmer's Memory function. + + + + + +Scene ID is set by this configuration. + +Note: The actual action of each SCENE ID are set by +SCENE_ACTUATOR_CONF(0x26) command. + + + + +This parameter allows to automatically switch off the device after specified time from switching on the light source. It may be useful when the Zerodim Z-Wave is installed in the stairway. + +Available settings: +0 - Function disabled. +1-32767 - time to turn off measured in seconds (1s-9.1h) + + + + + + + + + + + + + + diff --git a/openzwave/q-light/q-light_zerodim_2pol.xml b/openzwave/q-light/q-light_zerodim_2pol.xml new file mode 100644 index 00000000..63f19ec0 --- /dev/null +++ b/openzwave/q-light/q-light_zerodim_2pol.xml @@ -0,0 +1,120 @@ + + + + http://www.openzwave.com/device-database/0433:000E:0003 + images/q-light/q-light_zerodim_2pol.png + https://products.z-wavealliance.org/products/3881 + Zerodim + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3881/Instructions_ZerodimZwave_2pol_Norsk_A4.pdf + Zerodim Z-Wave by Q-light is a wireless smart home device. +Features: +- 0-99% dimming range +- 2-180W LED load +- Compatible with any Z-Wave or Z-Wave Plus Controller +- There is memorized function at power off +- OverLoad protection +- Soft start function +- SmartStart +- This device is a security enable Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enable Z-Wave Plus products. + + +1. Place the Zerodim Z-Wave within the direct range of your Z-Wave controller. +2. Identify switch rotary knob (turns the light on). +3. Set the main controller in (security/non-security) add mode (see the controller’s manual). +4. Quickly, three times press switch rotary knob. +5. Wait for the removing process to end. +6. Successful removing will be confirmed by the Z-Wave controller’s message. + + CEPT (Europe) + Q-light Zerodim Z-Wave + Resetting the Zerodim Z-Wave: +1. Quickly, nine times press switch rotary knob. +2. Wait for the resetting process to end, the lamp will be set to maximum brightness. + +Device reset statues: Turn on the light at maximum brightness. + + +Classic Learn Mode: +1. Place the Zerodim Z-Wave within the direct range of your Z-Wave controller. +2. Identify switch rotary knob (turns the light on). +3. Set the main controller in (security/non-security) add mode (see the controller’s manual). +4. Quickly, three times press switch rotary knob. +5. Wait for the adding process to end. +6. Successful adding will be confirmed by the Z-Wave controller’s message. + +SmartStart Learn Mode: +1. Scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. +2. No further action is required and the SmartStart product will be added automaticall within 10 minutes of being switched on in the network vicinity. +3. The QR Code and DSK are attached to the back of the product case, as shown below: + + + Initial release + fix associations + + + + + + +Set the desired value from 1 to 98% for the minimum dim level that the dimmer is restricted to, the dimmer will not go lower than the value set here. + + + + +Set the desired value from 2 to 99% for the maximum dim level that the dimmer is restricted to; the dimmer will not go higher than the value set here. + + + + +This parameter defines the percentage value of dimming step during the automatic control. + + + + +This parameter defines the time of single dimming step set in parameter 3 during the automatic control. + + + + +This parameter defines the percentage value of dimming step during the manual control. + + + + +This parameter defines the time of single dimming step setin parameter 5 during the manual control. + + + + Set the desired value from 0 to 1 to turn on/off the memory function.Setting this value to 0 turns off the dimmer's Memory fucntion.Setting this value to 1 truns on the dimmer's Memory function. + + + + + +Scene ID is set by this configuration. + +Note: The actual action of each SCENE ID are set by +SCENE_ACTUATOR_CONF(0x26) command. + + + + +This parameter allows to automatically switch off the device after specified time from switching on the light source. It may be useful when the Zerodim Z-Wave is installed in the stairway. + +Available settings: +0 - Function disabled. +1-32767 - time to turn off measured in seconds (1s-9.1h) + + + + + + + + + + + + + + diff --git a/openzwave/qees/reto-dimmer-plus.xml b/openzwave/qees/reto-dimmer-plus.xml new file mode 100644 index 00000000..ad80df90 --- /dev/null +++ b/openzwave/qees/reto-dimmer-plus.xml @@ -0,0 +1,41 @@ + + + http://www.openzwave.com/device-database/0095:0001:3101 + images/qees/reto-dimmer-plus.png + https://products.z-wavealliance.org/products/612/ + 311-BQ(WB)-A1 + http://www.qees.eu/support/support-center + U.S. / Canada / Mexico / CEPT (Europe) / CEPT (Europe) + QEES P311B dimmer with power meter + QEES RETO Shell Dimmer Plus is a highly aesthetic Z-Wave-controlled (EU frequency) 400W universal dimmer for any kind of dimmable load: Energy saving, halogen, LED and incandescent light bulbs. + +QEES RETO Shell Dimmer Plus is a wirelessly controlled universal dimmer for retrofit installation. It can be operated locally by pushing the top cover; this action will dim the local load. The device also monitors the power consumption of the load. + +QEES RETO Shell Dimmer Plus’s software can be upgraded “over the air”, allowing the device to receive additional features and bug fixes through firmware updates and software apps. This is a unique feature of all QEES products and it facilitates a future-proof, contemporary and flexible infrastructure solution for the building. + +QEES RETO Shell Dimmer Plus is compatible with all Z-Wave certified devices from other manufacturers. It also acts as a repeater inside your Z-Wave network increasing the range for your remote control. + +Like all QEES products, QEES RETO Shell Dimmer Plus has a self-calibrating built-in power meter and can switch off devices that otherwise would consume power when not needed. + http://www.qees.eu/products/z-wave/plus-retofit-series/turtle-shells/turtle-shell-dimmer-eu/product/76/98/Plus-Retofit-Series/Plus-RETO-Shell/qees-reto-shell-dimmer-plus-eu + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/594/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/595/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/611/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/612/xml + + + + + + + + true + + + + + + + + + diff --git a/openzwave/qees/reto-plugin-switch.xml b/openzwave/qees/reto-plugin-switch.xml new file mode 100644 index 00000000..21affc31 --- /dev/null +++ b/openzwave/qees/reto-plugin-switch.xml @@ -0,0 +1,39 @@ + + + http://www.openzwave.com/device-database/0095:0001:3103 + images/qees/reto-plugin-switch.png + https://products.z-wavealliance.org/products/614/ + QEES RETO Plug-in Dimmer Plus brings along comfort and elegance with an extremely easy setup and a unique design. With its help you can now wirelessly control all the dimmable loads you have inside your home. + + +QEES RETO Plug-in Dimmer Plus is a Z-Wave-controlled 400W universal dimmer (US frequency) with schuko plug-in socket outlet, built-in power meter, multi-color LED feedback and one programmable group for retrofit installation. + + +QEES RETO Plug-in Dimmer Plus’s software can be upgraded “over the air”, allowing the device to receive additional features or bug fixes through firmware updates and software apps.This is a unique feature of all QEES products and it facilitates a future-proof, contemporary and flexible infrastructure solution for the building. + + +QEES RETO Plug-in Dimmer Plus is compatible with all Z-Wave certified devices from other manufacturers. It also acts as a repeater inside your Z-Wave network increasing the range for your remote control. + + +Like all QEES products, QEES RETO Plug-in Dimmer Plus has a self-calibrating built-in power meter and can switch off the device that otherwise would consume power when not needed. + http://www.qees.eu/support + U.S. / Canada / Mexico / CEPT (Europe) / CEPT (Europe) + QEES P313B Plug-in dimmer + http://www.qees.eu/products/plus-retrofit-series/plugin-in-socket-outlets/plugin-in-socket-dimmer-us/product/72/106/Plus-Retrofit-Series/Plus-RETO-Plug-in/qees-reto-plug-in-dimmer-plus-us + 313-B(KFBGLE)(WB)-A1 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/596/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/597/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/613/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/614/xml + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHAA2.xml b/openzwave/qubino/ZMNHAA2.xml new file mode 100644 index 00000000..fb975ad8 --- /dev/null +++ b/openzwave/qubino/ZMNHAA2.xml @@ -0,0 +1,67 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + + 0 - Auto OFF disabled. 1 - 65535 => 0,01 second - 655,35 seconds. Auto OFF enabled with define time, step is 10mseconds. Default value 0 + + + + + + + + + + Set value from 0 - 100 (0%- 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 3 + + + + Set value means time interval (0 - 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) + + + + + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHADx.xml b/openzwave/qubino/ZMNHADx.xml new file mode 100644 index 00000000..a05ca114 --- /dev/null +++ b/openzwave/qubino/ZMNHADx.xml @@ -0,0 +1,181 @@ + + + http://www.openzwave.com/device-database/0159:0052:0002 + images/qubino/ZMNHADx.png + https://products.z-wavealliance.org/products/2795/ + ZMNHAD1 + REMOVAL FROM A ZWAVE NETWORK (Z-WAVE EXCLUSION) + +1. Connect the device to the power supply +2. Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion +3. Enable add/remove mode on your Z-Wave gateway (hub) +4. Toggle the switch connected to the I1 terminal 3 times within 5 seconds +OR +If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2 and 6 seconds +5. The device will be removed from your network but any custom configuration parameters will not be erased + + FACTORY RESET + +1. Connect the device to the power supply +2. Within the first minute (60 seconds) the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 5 seconds (5 times change switch state) +OR +If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds + +*By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted. Use this reset procedure only when the main gateway (hub) is missing or otherwise inoperable. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2795/Qubino_Flush 1 Relay PLUS extended manual_eng_2.2.pdf + Flush 1 Relay + CEPT (Europe) + AUTOMATICALLY ADDING THE DEVICE TO A Z-WAVE NETWORK (AUTO INCLUSION) + +1. Enable add/remove mode on your Z-Wave gateway (hub) +2. Connect the device to the power supply (with the temperature sensor already connected – sold separately*). +3. Auto-inclusion will be initiated within 5 seconds of connection to the power supply and the device will automatically enrol in your network + +MANUALLY ADDING THE DEVICE TO A Z-WAVE NETWORK (MANUAL INCLUSION) + +1. Enable add/remove mode on your Z-Wave gateway (hub) +2. Connect the device to the power supply (with the temperature sensor already connected*) +3. Toggle the switch connected to the I1 terminal 3 times within 5 seconds +OR +If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2 and 6 seconds +4. A new multi-channel device will appear on your dashboard +*If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor. + + +*Make sure the device is excluded from your network before connecting the temperature sensor. Switch off the power supply, connect the temperature sensor, and re-include the device to your network. + + The Flush 1 Relay controls on/off function for one electrical device. It measures power consumption of the connected device, and can be paired with a digital temperature sensor (sold separately). It supports push-button/momentary switches and toggle switches (default). + +The connection of a digital temperature sensor means you can create complex scenes and control any device relative to a set temperature range. The Qubino Flush 1 Relay also acts as a Z-Wave repeater to improve the range and stability of the Z-Wave network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2795/xml + Fix for 'module does not work on 1.6' - https://github.com/OpenZWave/open-zwave/issues/1820 + Add Instance Labels for i2, i3 and Temp Sensor Channels + Workaround for MCA assocation issue https://github.com/OpenZWave/open-zwave/issues/1895 + + + + + + + + + + + + + + + + + + + + + + + Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + 0 => Auto OFF disabled. 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). Auto OFF enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 + + + 0 - Auto OFF disabled. 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). Auto ON enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 + + + + + + + + + + + + + Set value from 0 - 100 (0%- 100%). 0 = Reporting Disabled. 1 - 100 = 1% - 100% and reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 10% + + + Set value means time interval (0 - 32535) in seconds, when power report is send. 0 = Reporting Disabled. 1 - 32535 = 1 second - 32535 seconds and reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Set value is added or subtracted to actual measured value by sensor. Available configuration parameters : default value 32536. 32536 offset is 0.0C. From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters : 0 = reporting disabled. 1 to 127 = 0,1C to 12,7C, step is 0,1C. Default value is 5 = 0,5C + + + + + + false + + + + + + + + + + + + + + + + + true + + + + + + + + + + false + + + diff --git a/openzwave/qubino/ZMNHBA2.xml b/openzwave/qubino/ZMNHBA2.xml new file mode 100644 index 00000000..34a56636 --- /dev/null +++ b/openzwave/qubino/ZMNHBA2.xml @@ -0,0 +1,93 @@ + + + + + + + + + + + + + + + + + + + + + Flush 2 relays module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + + 0 - Auto OFF disabled. 1 - 65535 => 0,01 second - 655,35 seconds. Auto OFF enabled with define time, step is 10mseconds. + Default value 0 + + + + 0 - Auto OFF disabled. 1 - 65535 => 0,01 second - 655,35 seconds. Auto OFF enabled with define time, step is 10 mseconds. + Default value 0 + + + + + + + + + + Set value from 0 - 100 (0%- 100%). + 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. + Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. + Default value 1 + + + + Set value from 0 - 100 (0%- 100%). + 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. + Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. + Default value 1 + + + + Set value means time interval (0 1 65535) in seconds, when power report is send. + 0 - Reporting Disabled. 1 - 65535 = 1 second - 65535 seconds. + Reporting enabled. Power report is send with time interval set by entered value. + Default value 300 (power report in Watts is send each 300s) + + + + Set value means time interval (0 1 65535) in seconds, when power report is send. + 0 - Reporting Disabled. 1 - 65535 = 1 second - 65535 seconds. + Reporting enabled. Power report is send with time interval set by entered value. + Default value 300 (power report in Watts is send each 300s) + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHBDx.xml b/openzwave/qubino/ZMNHBDx.xml new file mode 100644 index 00000000..85c6d7c5 --- /dev/null +++ b/openzwave/qubino/ZMNHBDx.xml @@ -0,0 +1,140 @@ + + + http://www.openzwave.com/device-database/0159:0051:0002 + images/qubino/ZMNHBDx.png + https://products.z-wavealliance.org/products/1528/ + ZMNHB + Please use this procedure only in the event that your network primary controller is missing or otherwise inoperable. + +If the service button S is pressed for mor ethan 6 seconds the module will be reset to the factory defoult state + Module Exclusion/Reset (Removing from Z-Wave network) +• Connect module to power supply +• bring module within maximum 1 meter (3feet) of the main controller, +• enable add/remove mode on main controller, +• press service button S for more than 6 second or +• press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply. +By this function all parameters of the module are set to default values and own ID is deleted. +If service button S is pressed more than 2 and less than 6second module is excluded, but configuration parameters are not set to default values + + Flush 2 relays module is used for switching on or off two electrical devices (e.g. lights, fans, etc ...). The module can be controlled either through Z-Wave network or through the wall switches. +The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. +Module measures power consumption of two electrical devices and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network. + + CEPT (Europe) + Module Inclusion (Adding to Z-Wave network) +• Connect module to power supply (with +temperature sensor connected - if purchased), +• enable add/remove mode on main controller +• auto-inclusion (works for about 5 seconds after connected to power supply) or +• press service button S for more than 2 second or +• press push button I1 three times within 3s (3 times change switch state within 3 seconds). +NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply. +NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply , connect the sensor and re-include the module. + + Qubino Flush 2 relays + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1528/Qubino_Flush 2 Relay PLUS extended manual_eng_2.2.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1528/xml + + + + + + + + + + + + + + + + + + + Flush 2 relays module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + When Q1 relay is ON it goes automatically OFF after set time. The timer is reset to zero every time the module receives an ON command from any source. Value is in 1s or 10ms depending on parameter 15 + + + When Q1 relay is OFF it goes automatically ON after set time. The timer is reset to zero every time the module receives an OFF command from any source. Value is in 1s or 10ms depending on parameter 15 + + + When Q2 relay is ON it goes automatically OFF after set time. The timer is reset to zero every time the module receives an ON command from any source. Value is in 1s or 10ms depending on parameter 15 + + + When Q2 relay is OFF it goes automatically ON after set time. The timer is reset to zero every time the module receives an OFF command from any source. Value is in 1s or 10ms depending on parameter 15 + + + Select the time units for auto on/off configuration. Applies tot he whole device + + + + + + + + + + Set value from 0 - 100 (0%- 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 1 + + + Set value from 0 - 100 (0%- 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 1 + + + Set value means time interval (0 1 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1 second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) + + + Set value means time interval (0 1 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1 second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) + + + Type of device that is connected to the output (NC or NO) + + + + + Type of device that is connected to the output (NC or NO) + + + + + Set value is added or subtracted to actual measured value by sensor. Available configuration parameters : default value 32536. 32536 offset is 0.0C. From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters : 0 = reporting disabled. 1 to 127 = 0,1C to 12,7C, step is 0,1C. Default value is 5 = 0,5C + + + + + + + + + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHCA2.xml b/openzwave/qubino/ZMNHCA2.xml new file mode 100644 index 00000000..eaffe301 --- /dev/null +++ b/openzwave/qubino/ZMNHCA2.xml @@ -0,0 +1,75 @@ + + + + + + + + + Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 to 100 = 1% to 100% Reporting enabled. Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 1 + + + + Set value means time interval (0 - 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) + + + + Module may include power and energy used by module itself in reports sent to the main controller + + + + + This parameter defines selection between two operating modes. NOTE: After setting a mode the module needs to be reconfigured. Please check the detailed description in the product manual. + + + + + This parameter defines the time necessary for slats to make a full turn (180 degrees). 0 tilting time disabled. Values range from 1 to 32767 = 0,01 seconds to 327,67 seconds. Default value 150. NOTE: If the time is set too high the shutter will move the slats up or down until the duration is reached. + + + This parameter defines slat position after up/down movement through UI or push button. + + + + + + This parameter defines shutter motor moving time of complete opening or complete closing. 0 moving time disabled (working with limit switches). 1 to 65535 = 0,1seconds to 6553,5 seconds After that time motor is stopped (relay goes to off state). Default value 0 + + + + Power threshold to be interpreted when motor reach the limit switch. Available settings: 0 to 127 (0-127 W). The value 0 means reaching a limit switch will not be detected. Default value: 10 (10W). + + + + By modifying the parameters setting from 0 to 1 a Shutter enters the calibration mode. Once the calibration process finished the parameter is reset back to 0. + + + + + The parameter defines the maximum time before motor power consumption is read after one of the relays is switched on. If there is no power consumption during this time the relay will switch off. Default value is 0 which signifies automatic detection. Value 3 signifies a time of 0,3 seconds. + + + The parameter defines the time delay between output relay switching (time between switching up/down and vice versa). The value 1 of this parameter corresponds to a 0,1 second delay. Default value is 5, which corresponds to 0,5 seconds. + + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHCDx.xml b/openzwave/qubino/ZMNHCDx.xml new file mode 100644 index 00000000..633aca87 --- /dev/null +++ b/openzwave/qubino/ZMNHCDx.xml @@ -0,0 +1,169 @@ + + + http://www.openzwave.com/device-database/0159:0052:0003 + images/qubino/ZMNHCDx.png + https://products.z-wavealliance.org/products/2505/ + + • Connect module to power supply (with + temperature sensor connected - if purchased), + • auto-inclusion (works for about 5 seconds after connected to power supply) or + • press push button I1 three times within 3s (3 times change switch state within 3 seconds) or + • press service button S (only applicable for 24 V SELV supply voltage) for more than 2 second. + + NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply. + + NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module. + + + • Connect module to power supply + • bring module within maximum 1 meter (3 feet) of the main controller, + • enable add/remove mode on main controller, + • press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or + • press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. + By this function all parameters of the module are set to default values and own ID is deleted. + + If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values. + + NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + NOTE: If the module is included with parameters 71 with + value different to default and + module reset is done, wait at least 30s before next inclusion + + + • press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or + • press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. + + NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + This Z-Wave module is used to control the motor of blinds, rollers, shades, venetian blinds, etc … The module can be controlled either through a Z-Wave network or through the wall switch. Precise positioning is supported for motors equipped with mechanical or electronic end switches. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of motor and support connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-Wave network. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2505/Qubino_Flush Shutter PLUS extended manual_eng_2.2.pdf + ZMNHCD3 + Flush Shutter + CEPT (Europe) / Australia / New Zealand / U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2376/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2504/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2505/xml + Fixed problem of lifeline group 1.1 receives no update (https://www.domoticz.com/forum/viewtopic.php?f=24&t=29715#p225812) and fixed format of this XML + + + + + + + + Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 1 + + + Set value means time interval (0 - 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) + + + This parameter defines selection between two available operating modes + + + + + + This parameter defines the time necessary for slats to make full turn (180 degrees) + default value 150 = 1,5 seconds + 0 - Tilting time disabled + 1 - 32767 = 0,01seconds - 327,67 seconds + + + + + This parameter defines slats position after up/down movement through Z-wave or push-buttons + Slats return to previously set position only in case of + + + + + + + This parameter defines shutter motor moving time of complete opening or complete closing. + Default value 0 + 0 - moving time disabled (working with limit switches). + 1 - 65535 = 0,1seconds - 6553,5seconds + After that time motor is stopped (relay goes to off state) + + + + + Power threshold to be interpreted when motor reach the limit switch. + default value 10 = 10W + 0 - 127 = 1-127 W. The value 0 means reaching a limit switch will not be detected. + + + + By modifying the parameters setting from 0 to 1 a Shutter enters the calibration mode + + + + + + This parameter defines the max time before motor power consumption is read after one of the relays is switched ON. + If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, motor in end position) the relay will switch OFF. + Time is defined by entering it manually. + default value 0 = time is set automatically + 3 - 50 = 0,3seconds - 5seconds (100ms resolution) + + + + + This parameter defines the minimum time delay between next motor movement (minimum time between switching motor off and on again). + default value 5 = 500ms + 1 - 30 = 0,1seconds - 3seconds (100ms resolution) + + + + + Set value is added or subtracted to actual measured value by sensor. + default value 32536 + 32536 - offset is 0.0C + From 1 to 100 - value from 0.1 C to 10.0 C is added to actual measured temperature. + From 1001 to 1100 - value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter + default value 5 = 0,5C + 0 - Reporting disabled + 1-127 = 0,1C - 12,7C, step is 0,1C + + + + + + + false + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHDA2.xml b/openzwave/qubino/ZMNHDA2.xml new file mode 100644 index 00000000..2492f6e0 --- /dev/null +++ b/openzwave/qubino/ZMNHDA2.xml @@ -0,0 +1,81 @@ + + + http://www.openzwave.com/device-database/0159:0001:0001 + images/qubino/ZMNHDA2.png + https://products.z-wavealliance.org/products/1231/ + ZMNHDA2 + GOAP Qubino Dimmer + CEPT (Europe) + flush zwave dimmer + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1231/xml + + + + + + + + + + + + + Default value 0. + + + + + Default value 0. + + + + + Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. Default value 0. + + + + + + + Default value 0. + + + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 5. + + + Set value means time interval (0 - 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1 second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s). + + + 1 - 98 = 1% - 98%, step is 1%. Minimum dimming values is set by entered value. Default value 1 (Minimum dimming value is 1%). NOTE: The minimum level may not be higher than the maximum level. + + + 2 - 99 = 2% - 99%, step is 1%. Maximum dimming values is set by entered value. Default value 99 (Maximum dimming value is 99%). NOTE: The maximum level may not be lower than the minimum level. + + + Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through. 1- 255 = 10mseconds - 2550mseconds (2,55s), step is 10mseconds. Default value 100 (Dimming time between min. and max. dimming values is 1s). + + + Time of moving the Dimmer between min. and max dimming values by continues hold of push button I1. 1- 255 = 1 second - 255 seconds. Default value 3 (Dimming time between min. and max. dimming values is 3s). + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHDDx.xml b/openzwave/qubino/ZMNHDDx.xml new file mode 100644 index 00000000..1c61d2e9 --- /dev/null +++ b/openzwave/qubino/ZMNHDDx.xml @@ -0,0 +1,232 @@ + + + http://www.openzwave.com/device-database/0159:0051:0001 + images/qubino/ZMNHDDx.png + https://products.z-wavealliance.org/products/2114/ + • Connect module to power supply +• bring module within maximum 1 meter (3feet) of the main controller, +• enable add/remove mode on main controller, +• press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. +By this function all parameters of the module are set to default values and own ID is deleted. +If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values. +NOTE: If the module is included with parameters 100 or 101 with values different to default and module reset is done, wait at least 30s before next inclusion + + This Z-Wave module is used for dimming the bulb or to manage the speed of a fan. The module can be controlled either through a Z-Wave network or through the wall switch. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of bulb or fan and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2114/Qubino_Flush Dimmer PLUS extended manual_eng_2.3.pdf + CEPT (Europe) / Australia / New Zealand + • Connect module to power supply (with +temperature sensor connected - if purchased), +• enable add/remove mode on main controller +• auto-inclusion (works for about 2 minutes after connected to power supply) or +• press push button I1 three times within 3s (3 times change switch state within 3 seconds) or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 2 second. +NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply. +NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module. + + ZMNHDD2 + Qubino Flush Dimmer + • press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. + +Please use reset procedure only when the network primary controller is missing or otherwise inoperable. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2077/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2114/xml + Tweak config label for consistency of both buttons + fixes: qubino wrong config parameter 68 in ZMNHDDX.xml #1995 + + + + + + + + + + + + + + + + + + + + + + + Default value 0 + + + + + Flush dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + Default value 255. + + + + + + + 0 - Auto OFF disabled. + 1 second to 32536 seconds Auto OFF enabled with defined time, step is 1 second. + Default value 0. + + + 0 - Auto ON disabled. + 1 second to 32535 seconds Auto ON enabled with defined time, step is 1 second. + Default value 0. + + + Dimming is done by push button or switch connected to I1 (by default). + Enabling 3-way switch, dimming can be controlled by push button or switch connected to I1 and I2. + Default value 0. + + + + + + + If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value. + Default value 0. + + + + + Default value 0. + + + + + Set value from 0 - 100 (0% - 100%). + 0 - Reporting Disabled. + 1 - 100 = 1% - 100% Reporting enabled. + Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. + Default value 5. + + + Set value means time interval (0 - 32767) in seconds, when power report is send. + 0 - Reporting Disabled. + 1 second to 32767 seconds reporting enabled. + Power report is send with time interval set by entered value. + Default value 300 (power report in Watts is send each 300s). + + + 1 - 98 = 1% - 98%, step is 1%. Minimum dimming values is set by entered value. + Default value 1 (Minimum dimming value is 1%). + + + 2 - 99 = 2% - 99%, step is 1%. Maximum dimming values is set by entered value. + Default value 99 (Maximum dimming value is 99%). + + + Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through. + 1- 255 = 10mseconds - 2550mseconds (2,55s), step is 10mseconds. + Default value 100 (Dimming time between min. and max. dimming values is 1s). + + + Time of moving the Dimmer between min. and max dimming values by continues hold of push button I1. + 1- 255 = 1 second - 255 seconds. + Default value 3 (Dimming time between min. and max. dimming values is 3s). + + + This parameter is used with association group 4. + A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. + A receiving device MUST ignore the start level if the Ignore Start Level bit is 1. + Default value 0. + + + + + This parameter is used with association group 3. + The Duration field MUST specify the time that the transition should take from the current value to the new target value. + A supporting device SHOULD respect the specified Duration value. + Default value 0. + + + + + Enabling I2 means that Endpoint (I2) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + Endpoint device type selection: notification sensor (1 - 6) sensor binary (9). + NOTE: After parameter change, module has to be re included into the network in order setting to take effect! + Default value 1. + + + + + + + + + + + Enabling I3 means that Endpoint (I3) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + Endpoint device type selection: notification sensor (1 - 6) sensor binary (9). + NOTE: After parameter change, module has to be re included into the network in order setting to take effect! + Default value 1. + + + + + + + + + + + Set value is added or subtracted to actual measured value by sensor. + 32536 : offset is 0.0C. + From 1 to 100 : value from 0.1 C to 10.0 C is added to actual measured temperature. + From 1001 to 1100 : value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + Default value 32536. + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. + 0 : Reporting disabled. + 1- 127 = 0,1C - 12,7C, step is 0,1C. + Default value 5 = 0,5C change. + + + + + + + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHHDx.xml b/openzwave/qubino/ZMNHHDx.xml new file mode 100644 index 00000000..9a136b32 --- /dev/null +++ b/openzwave/qubino/ZMNHHDx.xml @@ -0,0 +1,154 @@ + + + + + + With this parameter, you can select between push-button (momentary) and on/off toggle switch types. + + + + + With this parameter, you can change the device presentation on the user interface. + + + + + + 0 - Auto OFF Disabled. + 1 - 32536 = 1 - 32536 seconds - Auto OFF timer enabled for a given amount of seconds. + Default value 0. + + + + + 0 - Auto ON Disabled. + 1 - 32536 = 1 - 32536 seconds - Auto ON timer enabled for a given amount of seconds. + Default value 0. + + + + + If the Double click function is enabled, a fast double click on the push-button will set the dimming level to the maximum dimming value. + + + + + + Default value 0. + + + + + Set value from 0 - 100 (0% - 100%). + 0 - Reporting Disabled. + 1 - 100 = 1% - 100% Reporting enabled. + Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. + Default value 5. + + + Set value means time interval (0 - 32767) in seconds, when power report is send. + 0 - Reporting Disabled. + 1 second to 32767 seconds reporting enabled. + Power report is send with time interval set by entered value. + Default value 300 (power report in Watts is send each 300s). + + + 1 - 98 = 1% - 98%, step is 1%. Minimum dimming values is set by entered value. + Default value 1 (Minimum dimming value is 1%). + + + 2 - 99 = 2% - 99%, step is 1%. Maximum dimming values is set by entered value. + Default value 99 (Maximum dimming value is 99%). + + + Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through the controller. + 1 - 127 = 1 second - 127 seconds. + Default value 1 (Dimming time between min. and max. dimming values is 1s). + + + + Choose the time during which the Dimmer will move between the min. and max. dimming values during a continuous press of the push-button I1, by an associated device or through the UI controls (BasicSet, SwitchMultilevelSet) + default value 3 = 3s. + 1-127 = 1 second – 127 seconds. + 128 – 253 = 1 minute – 126 minutes. + + + + + Choose whether the device should use (or disregard) the start dimming level value. + If the device is configured to use the start level, it should start the dimming process from the currently set dimming level. + This parameter is used with association group 3 + + + + + + + Choose the time during which the device will transition from the current value to the new target value. + This parameter applies to the association group 3. + default value 0 (dimming duration according to parameter 66). + 1 - 127 (from 1 to 127 seconds). + + + + + + The function allows for turning off the controlled device in case of exceeding the defined power for more than 5s. + Controlled device can be turned back on by input I1 or sending a control frame. + 0 = function not active + 1–200=1W–200W + + + + + Choose when will be the calibration procedure triggered. + + + + + + + + Whit this parameter you can check the calibration status. + + + + + + + This parameter defines the module behaviour in case it receives any Alarm/Notification events. + + + + + + + + + This parameter defines the time interval of the blinking state, once the module receives an alarm/notification event. + Minimum step increase is 1 minute. + 1 - 127 (from 1 to 125 minutes). + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHIA2.xml b/openzwave/qubino/ZMNHIA2.xml new file mode 100644 index 00000000..4d2f497b --- /dev/null +++ b/openzwave/qubino/ZMNHIA2.xml @@ -0,0 +1,103 @@ + + + + + + + + + + + + + + + + + + + + + + Flush on off thermostat module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + + When I2 is pressed set point will be set according to the value of this parameter. + default value 65535 + 65535 - input I2 does not influence on the set point + From 0 to 990 - set point from 0.0 C to 99.0 C + From 1001 to 1150 - set point from -0.1 C to -15.0 C + + + + + When I3 is pressed set point will be set according to the value of this parameter. + default value 65535 + 65535 - input I2 does not influence on the set point + From 0 to 990 - set point from 0.0 C to 99.0 C + From 1001 to 1150 - set point from -0.1 C to -15.0 C + + + + + + + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 5 + + + Set value means time interval (0 - 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1 second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) + + + This parameter defines temperature min difference between real measured temperature and set-point temperature to turn heating on. The parameter can be set from 0 to 255 where 0 to 128 means from 0.0 C to 12.8 C and from 129 to 255 means from - 0.0 C to -12.8 C. + + + This parameter defines temperature min difference between real measured temperature and set-point temperature to turn heating off. The parameter can be set from 0 to 255 where 0 to 128 means from 0.0 C to 12.8 C and from 129 to 255 means from - 0.0 C to -12.8 C. + + + Set value means at which temperature the heating will be turned on even if the thermostat was manually set to off. The parameter can be set from 0 to 255 where 0 to 128 means from 0.0 C to 12.8 C and from 129 to 255 means from - 0.0 C to -12.8 C. + + + + Default value 50 (Minimum Temperature alarm is 5.0C) + 1 - 1000 = 0.1C - 100.0C, step is 0.1C. + Minimum temperature alarm is set by entered value. In case is set value out of this range, module is changing set value automatically to default value + + + + + Default value 700 (Minimum Temperature alarm is 70.0C) + 1 - 1000 = 0.1C - 100.0C, step is 0.1C. + Maximum temperature alarm is set by entered value. In case is set value out of this range, module is changing set value automatically to default value + + + + Set value means the type of the heating device that is connected to the relay output. The heating device type can be normally open (NO) or normally close (NC). + + + + + + + + + + + + + + + + + + + 0 + + + diff --git a/openzwave/qubino/ZMNHIDxS1.xml b/openzwave/qubino/ZMNHIDxS1.xml new file mode 100644 index 00000000..d9d689c3 --- /dev/null +++ b/openzwave/qubino/ZMNHIDxS1.xml @@ -0,0 +1,212 @@ + + + + + + + 2 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Flush on off thermostat module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + + When I2 is pressed set point will be set according to the value of this parameter. + Default value 32767. + 32767 - input I2 does not influence on the set point + From 0 to 990 - set point from 0.0 C to 99.0 C + From 1001 to 1150 - set point from -0.1 C to -15.0 C + + + + + When I3 is pressed set point will be set according to the value of this parameter. + Default value 32767. + 32767 - input I2 does not influence on the set point + From 0 to 990 - set point from 0.0 C to 99.0 C + From 1001 to 1150 - set point from -0.1 C to -15.0 C + + + + If Disabled, after a power failure, module return to OFF position. + + + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 3 + + + Set value means time interval (0 - 65535) in seconds, when power report is send. 0 - Reporting Disabled. + 1 - 65535 = 1 second - 65535 seconds. + Reporting enabled. + Power report is send with time interval set by entered value. + Default value 300 (power report in Watts is send each 300s) + + + This parameter defines temperature min difference between real measured temperature and set-point temperature to turn heating on. + The parameter can be set from 0 to 255 where 0 to 128 means from 0.0 C to 12.8 C and from 129 to 255 means from - 0.0 C to -12.8 C. + Default value 132 (-0.5 C) + + + + This parameter defines temperature min difference between real measured temperature and set-point temperature to turn heating off. + The parameter can be set from 0 to 255 where 0 to 128 means from 0.0 C to 12.8 C and from 129 to 255 means from - 0.0 C to -12.8 C. + Default value 5 (+0.5 C) + + + + Set value means at which temperature the device will be turned on even if the thermostat was manually set to off. + 0 - 127 = 0.0C - 12.7 C. + 128 - 254 = -0.1C - 12.6 C. + 255 - Antifreeze functionality disabled. + Default value 50 (5.0 C). + + + + + Default value 50 (Minimum Temperature alarm is 5.0C) + 1 - 1000 = 0.1C - 100.0C, step is 0.1C. + Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. + + + + + Default value 700 (Minimum Temperature alarm is 70.0C) + 1 - 1000 = 0.1C - 100.0C, step is 0.1C. + Too high temperature limit is set by entered value. In case is set value out of this range, module is changing automatically set value to default value. + + + + Set value means the type of the device that is connected to the relay output. The device type can be normally open (NO) or normally close (NC). + Available config. parameters (data type is 1 Byte DEC): + default value 0 + 0 - When system is turned off the output is 0 V. + 1 - When system is turned off the output is 230 V. + + + + + + Enabling I1 means that Endpoint (I1) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Enabling I2 means that Endpoint (I2) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Enabling I3 means that Endpoint (I3) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Set value is added or subtracted to actual measured value by sensor. + From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. + From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + Default value 32536. 32536 offset is 0.0C. + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. + 0 = reporting disabled. + 1 to 127 = 0,1C to 12,7C, step is 0,1C. + Default value is 5 = 0,5C + + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHIDxS2.xml b/openzwave/qubino/ZMNHIDxS2.xml new file mode 100644 index 00000000..68c6e1ae --- /dev/null +++ b/openzwave/qubino/ZMNHIDxS2.xml @@ -0,0 +1,431 @@ + + + + http://www.openzwave.com/device-database/0159:0051:0005 + images/qubino/ZMNHIDx.png + + + 1. Connect the device to the power supply + 2. Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion + 3. Enable add/remove mode on your Z-Wave gateway (hub) + 4. Toggle the switch connected to the I1 terminal 3 times within 3 seconds + OR + If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2 and 6 seconds + 5. The device will be removed from your network but any custom configuration parameters will not be erased + + The Qubino Flush On/Off Thermostat 2 is ideal for remotely controlling electric + or water-based underfloor heating systems, electric water heaters, hot water pumps, electric radiators, and + similar devices. + + + CEPT (Europe) + + 1. Enable add/remove mode on your Z-Wave gateway (hub) + 2. Connect the device to the power supply (with the temperature sensor already connected*) + 3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds. The device has to get On/Off signal 3 times, meaning 3 times push on the push button or 6 times press of the switch. + OR + If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2 and 6 seconds + 4. A new multi-channel device will appear on your dashboard + *If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor. + + ZMNHID1 + Qubino Flush On Off thermostat Z-Wave+ H1S2P1 + + 1. Connect the device to the power supply + 2. Within the first minute (60 seconds) the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 3 seconds (5 times change switch state) + OR + If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds + + + Add missing parameter 59 + + + + + + + + + + + + + + + + + + 2 + 0 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Flush on off thermostat module responds to commands ALL ON / ALL OFF that may be sent by the main + controller or by other controller belonging to the system. + + + + + + + + + When I1 is pressed set point will be set according to the value of this parameter. + Default value 1. + 32767 - input I1 does not influence on the set point + From 0 to 990 - set point from 0.0 C to 99.0 C + From 1001 to 1150 - set point from -0.1 C to -15.0 C + + + + + When I3 is pressed set point will be set according to the value of this parameter. + Default value 32767. + 32767 - input I2 does not influence on the set point + From 0 to 990 - set point from 0.0 C to 99.0 C + From 1001 to 1150 - set point from -0.1 C to -15.0 C + + + + + When I3 is pressed set point will be set according to the value of this parameter. + Default value 32767. + 32767 - input I3 does not influence on the set point + From 0 to 990 - set point from 0.0 C to 99.0 C + From 1001 to 1150 - set point from -0.1 C to -15.0 C + + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. + Power report is send (push) only when actual power in Watts in real time change for more than set + percentage comparing to previous actual power in Watts, step is 1%. Default value 0 + + + + Set value means time interval (0 - 65535) in seconds, when power report is send. 0 - Reporting + Disabled. + 1 - 65535 = 1 second - 65535 seconds. + Reporting enabled. + Power report is send with time interval set by entered value. + Default value 0 + + + + This parameter defines temperature min difference between real measured temperature and set-point + temperature to turn heating on. + The parameter can be set from 0 to 1127 where 0 to 127 means from 0.0 C to 12.7 C and from 1001 to 1127 + means from - 0.1 C to -12.7 C. + Default value 132 (-0.5 C) + + + + This parameter defines temperature min difference between real measured temperature and set-point + temperature to turn heating off. + The parameter can be set from 0 to 1127 where 0 to 127 means from 0.0 C to 12.7 C and from 1001 to 1127 + means from - 0.1 C to -12.7 C. + Default value 5 (+0.5 C) + + + + Set value means at which temperature the device will be turned on even if the thermostat was manually + set to off. + 0 - 127 = 0.0C - 12.7 C. + 1001 - 1127 = -0.1C - 12.6 C. + 255 - Antifreeze functionality disabled. + Default value 50 (5.0 C). + + + + + This parameter determines how the device will operate if it will operate in the heating mode or in the + cooling mode. + The range of the hysteresis will remain the same, only operation will change from heating to cooling and + vice versa + + + + + + + Default value 50 (Minimum Temperature alarm is 5.0C) + 1 - 1000 = 0.1C - 100.0C, step is 0.1C. + 1001 - 1150 = -0.1 C - 15 C + Too low temperature limit is set by entered value. In case is set value out of this range, module is + changing set value automatically to default value. + + + + + Default value 700 (Minimum Temperature alarm is 70.0C) + 1 - 1000 = 0.1C - 100.0C, step is 0.1C. + Too high temperature limit is set by entered value. In case is set value out of this range, module is + changing automatically set value to default value. + + + + Set value means the type of the device that is connected to the relay output. The device type can be + normally open (NO) or normally close (NC). + Available config. parameters (data type is 1 Byte DEC): + default value 0 + 0 - When system is turned off the output is 0 V. + 1 - When system is turned off the output is 230 V. + + + + + + + Default value 0 + 1 - 32000 seconds + If the value of the parameter is different to 0, means that the influence of this input to heating or + cooling will react after inserted time. + This parameter has influence only when the window sensor functionality is selected by the parameter no. + 11. + + + + + Default value 0 + 1 - 32000 seconds + If the value of the parameter is different to 0, means that the influence of this input to heating or + cooling will react after inserted time. + This parameter has influence only when the window sensor functionality is selected by the parameter no. + 11. + + + + + Default value 0 + 1 - 32000 seconds + If the value of the parameter is different to 0, means that the influence of this input to heating or + cooling will react after inserted time. + This parameter has influence only when the condense sensor functionality is selected by the parameter + no. 12. + + + + + Default value 0 + 1 - 32000 seconds + If the value of the parameter is different to 0, means that the influence of this input to heating or + cooling will react after inserted time. + This parameter has influence only when the condense sensor functionality is selected by the parameter + no. 12. + + + + + Default value 0 + 1 - 32000 seconds + If the value of the parameter is different to 0, means that the influence of this input to heating or + cooling will react after inserted time. + This parameter has influence only when the flood sensor functionality is selected by the parameter no. + 13. + + + + + Default value 0 + 1 - 32000 seconds + If the value of the parameter is different to 0, means that the influence of this input to heating or + cooling will react after inserted time. + This parameter has influence only when the flood sensor functionality is selected by the parameter no. + 13. + + + + + Enabling I1 means that Endpoint (I1) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and + then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Enabling I2 means that Endpoint (I2) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and + then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Enabling I3 means that Endpoint (I3) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and + then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Set value is added or subtracted to actual measured value by sensor. + From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. + From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + Default value 32536. 32536 offset is 0.0C. + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change + defined by this parameter. + 0 = reporting disabled. + 1 to 127 = 0,1C to 12,7C, step is 0,1C. + Default value is 5 = 0,5C + + + + + If digital temperature sensor is not connected, module can grab measured temperature from external + secondary module. + Default value is 0. + + + + + + + + + + If digital temperature sensor is not connected, module can grab measured temperature from external + battery powered room sensor defined by this paramater. + 0 = external battery powered room sensor not in function. + 1 to 254 = Node ID of external battery powered room sensor. + Default value is 0 + + + + + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHJA2.xml b/openzwave/qubino/ZMNHJA2.xml new file mode 100644 index 00000000..f61d5801 --- /dev/null +++ b/openzwave/qubino/ZMNHJA2.xml @@ -0,0 +1,90 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHJD1.xml b/openzwave/qubino/ZMNHJD1.xml new file mode 100644 index 00000000..b82974cf --- /dev/null +++ b/openzwave/qubino/ZMNHJD1.xml @@ -0,0 +1,90 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHKDx.xml b/openzwave/qubino/ZMNHKDx.xml new file mode 100644 index 00000000..65deeb3c --- /dev/null +++ b/openzwave/qubino/ZMNHKDx.xml @@ -0,0 +1,251 @@ + + + + + 2 + 0 + + + + + + + + + + + + + + + + + + + + + + + + + + Flush on off thermostat module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + + Default value 1. + 32767 - input I1 does not influence on the Heat and Cool process + 1 - Input I1 changes the mode of the thermostat between Off and Auto. In this case, function on window sensor is disabled. + 2 - Input I1 influences on cooling and heating valves according to status of window sensor. In this case, function of Off and Auto selection bi I1 us disabled. + + + + + Default value 32767. + 32767 - input I2 does not influence on the Heat and Cool process + From 0 to 990 - set point from 0.0 C to 99.0 C + From 1001 to 1150 - set point from -0.1 C to -15.0 C + 2000 - Input I2 influences on the cooling valve according to status of condense sensor + + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 0 + + + Set value means time interval (0 - 32767) in seconds, when power report is send. 0 - Reporting Disabled. + 1 - 32767 = 1 second - 32767 seconds. + Reporting enabled. + Power report is send with time interval set by entered value. + Default value 0 + + + This parameter defines temperature min difference between real measured temperature and set-point temperature to turn heating on. + The parameter can be set from 0 to 1127 where 0 to 127 means from 0.0 C to 12.7 C and from 1001 to 1127 means from - 0.1 C to -12.7 C. + Default value 1010 (-1.0 C) + + + + This parameter defines temperature min difference between real measured temperature and set-point temperature to turn heating off. + The parameter can be set from 0 to 1127 where 0 to 127 means from 0.0 C to 12.7 C and from 1001 to 1127 means from - 0.1 C to -12.7 C. + Default value 2 (+0.2 C) + + + + This parameter defines temperature min difference between real measured temperature and set-point temperature to turn cooling on. + The parameter can be set from 0 to 1127 where 0 to 127 means from 0.0 C to 12.7 C and from 1001 to 1127 means from - 0.1 C to -12.7 C. + Default value 5 (0.5 C) + + + + This parameter defines temperature min difference between real measured temperature and set-point temperature to turn cooling off. + The parameter can be set from 0 to 1127 where 0 to 127 means from 0.0 C to 12.7 C and from 1001 to 1127 means from - 0.1 C to -12.7 C. + Default value 1002 (-0.2 C) + + + + Set value means at which temperature the device will be turned on even if the thermostat was manually set to off. + 0 - 127 = 0.0C - 12.7 C. + 1001 - 1127 = -0.1C - 12.6 C. + 255 - Antifreeze functionality disabled. + Default value 50 (5.0 C). + + + + + Default value 50 (Minimum Temperature alarm is 5.0C) + 1 - 1000 = 0.1C - 100.0C, step is 0.1C. + 1001 - 1150 = -0.1 C - 15 C + Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. + + + + + Default value 700 (Minimum Temperature alarm is 70.0C) + 1 - 1000 = 0.1C - 100.0C, step is 0.1C. + Too high temperature limit is set by entered value. In case is set value out of this range, module is changing automatically set value to default value. + + + + Set value means the type of the device that is connected to the Q1 output. The device type can be normally open (NO) or normally close (NC). + Available config. parameters (data type is 1 Byte DEC): + default value 0 + 0 - When system is turned off the output is 0 V. + 1 - When system is turned off the output is 230 V. + + + + + Set value means the type of the device that is connected to the Q2 output. The device type can be normally open (NO) or normally close (NC). + Available config. parameters (data type is 1 Byte DEC): + default value 0 + 0 - When system is turned off the output is 0 V. + 1 - When system is turned off the output is 230 V. + + + + + + Default value 0 + 1 - 32000 seconds + If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. + This parameter has influence only when the window sensor functionality is selected by the parameter no. 11. + + + + + Default value 0 + 1 - 32000 seconds + If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. + This parameter has influence only when the window sensor functionality is selected by the parameter no. 11. + + + + + Default value 0 + 1 - 32000 seconds + If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. + This parameter has influence only when the condense sensor functionality is selected by the parameter no. 12. + + + + + Default value 0 + 1 - 32000 seconds + If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. + This parameter has influence only when the condense sensor functionality is selected by the parameter no. 12. + + + + + Enabling I1 means that Endpoint (I1) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Enabling I2 means that Endpoint (I2) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Set value is added or subtracted to actual measured value by sensor. + From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. + From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + Default value 32536. 32536 offset is 0.0C. + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. + 0 = reporting disabled. + 1 to 127 = 0,1C to 12,7C, step is 0,1C. + Default value is 5 = 0,5C + + + + If digital temperature sensor is not connected, module can grab measured temperature from external secondary module. + Default value is 0. + + + + + + + + + + If digital temperature sensor is not connected, module can grab measured temperature from external battery powered room sensor defined by this paramater. + 0 = external battery powered room sensor not in function. + 1 to 254 = Node ID of external battery powered room sensor. + Default value is 0 + + + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHLAx.xml b/openzwave/qubino/ZMNHLAx.xml new file mode 100644 index 00000000..f4207fc5 --- /dev/null +++ b/openzwave/qubino/ZMNHLAx.xml @@ -0,0 +1,158 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + When I2 is pressed set point will be set according to the value of this parameter. + + + + + + + Default value 1 + 65535 - input I1 does not influence on the heat/ cool process + 1 - input I1 changes the mode of the thermostat between Off and Auto. In this case function on flood sensor (if connected) is disabled. + 2 - input I1 influences on cooling and heating valves according to status of flood sensor. In this case function of Off and Auto selection by I1 is disabled + + + + + + default value 65535 | 65535 - input I2 does not influence on the heat/ cool process | From 0 to 990 - Temperature set point from 0.0 C to 99.0 C. When I2 is pressed, temperature set point is automatically set to value defined here. In this case function of condense sensor is disabled. | From 1001 to 1150 - Temperature set point from -0.1 C to -15.0 + C. When I2 is pressed, temperature setpoint is automatically set to value defined here. In this case function of condense sensor is disabled. | 2000 - Input I2 influences on the cooling valve according to status of condense sensor, In this case function of setpoint selection with I2 is disabled. + + + default value 65535 | 65535 - input I3 does not influence on the heat/ cool process | 1 - input I3 changes the mode of the thermostat between Heat and Cool. In this case function on window sensor is disabled. | 2 - input I3 influences on cooling and heating valves according to status of window sensor. In this case function of Heat and Cool selection by I3 is disabled + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 0 + + + Set value means time interval (0 - 32767) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 32767 = 1 second - 32767 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) + + + Set value means at which temperature the heating will be turned on even if the thermostat was manually set to off. The parameter can be set from 0 to 255 where 0 to 128 means from 0.0 C to 12.8 C and from 129 to 255 means from - 0.0 C to -12.8 C. + + + default value 100 (Maximum PWM value) | 2-100 = 2%-100%, step is 1%. Max. PWM set by entered value. NOTE: The maximum level may not be lower than the minimum level! + + + default value 0 (Minimum PWM value is 0%) | 1-99 = 1%-99%, step is 1%. Max. PWM set by entered value. NOTE: The Minimim level may not exceed Maximum level! + + + Default value 10 (Cycle duration set to 10s) | 1-127 = 1-127s, step is 1s. PWM cycle duration set by entered value. NOTE: PWM cycle duration define the summary of all ON plus OFF time periods. For example if Output is set to 70% with PWM cycle duration of 20s, output will be ON for 14s then OFF 6s, again 14s ON, etc + + + + When value is set to ZERO PID inside deadband is forced to zero. LASTVALUE means that PID remains on same level as was before entering into deadband + + + + + default value 5 (0,5 C) | 0-127 - 0.0 C to 12.7 C, step is 0,1C. NOTE: This parameter defines the zone where PID is not active. If the temperature difference between actual and setpoint is bigger than PID deadband, then the PID will start to regulate the system, otherwise the PID is zero or fixed + + + default value 5 (0,5 C) | 0-127 - 0.0 C to 12.7 C, step is 0,1C. NOTE: Parameter defines the time between samples. On each sample the + controller capture difference between SP-act + + + default value 100 | 0 -1000 - P value, step is 1 + + + default value 1 | 0 -1000 - I value, step is 1 + + + default value 1 | 0 -1000 - D value, step is 1 + + + default : Heat mode | Heat mode | Cool mode + + + + + Default value 50 (Too low temperature limit is 5.0C) | 1 - 1000 = 0.1C - 100.0C, step is 0.1C. Too low temperature limit is set by entered value. In case measured temperature is below set value, module sends BasicSet value. + + + Default value 700 (too high temperature limit is 70.0C) | 1 - 1000 = 0.1C - 100.0C, step is 0.1C. Too high temperature limit is set by entered value. In case measured temperature is higher than set value, module sends BasicSet value. + + + + + + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 11 must be set to 2! NOTE: Device status on UI change immediately + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 11 must be set to 2! NOTE: Device status on UI change immediately + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 12 must be set to 2000! + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 12 must be set to 2000! + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 13 must be set to 2! NOTE: Device status on UI change immediately + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 13 must be set to 2! NOTE: Device status on UI change immediately + + + + + + 0 + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHLDx.xml b/openzwave/qubino/ZMNHLDx.xml new file mode 100644 index 00000000..a2cab2d0 --- /dev/null +++ b/openzwave/qubino/ZMNHLDx.xml @@ -0,0 +1,233 @@ + + + + + + + + + + + + + 2 + 0 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Default value 1 + 32767 - input I1 does not influence on the heat/ cool process + 1 - input I1 changes the mode of the thermostat between Off and Auto. In this case function on flood sensor (if connected) is disabled. + 2 - input I1 influences on cooling and heating valves according to status of flood sensor. In this case function of Off and Auto selection by I1 is disabled + + + + + + default value 32767 | 32767 - input I2 does not influence on the heat/ cool process | From 0 to 990 - Temperature set point from 0.0 C to 99.0 C. When I2 is pressed, temperature set point is automatically set to value defined here. In this case function of condense sensor is disabled. | From 1001 to 1150 - Temperature set point from -0.1 C to -15.0 + C. When I2 is pressed, temperature setpoint is automatically set to value defined here. In this case function of condense sensor is disabled. | 2000 - Input I2 influences on the cooling valve according to status of condense sensor, In this case function of setpoint selection with I2 is disabled. + + + default value 32767 | 32767 - input I3 does not influence on the heat/ cool process | 1 - input I3 changes the mode of the thermostat between Heat and Cool. In this case function on window sensor is disabled. | 2 - input I3 influences on cooling and heating valves according to status of window sensor. In this case function of Heat and Cool selection by I3 is disabled + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 0 + + + Set value means time interval (0 - 32767) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 32767 = 1 second - 32767 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 0 + + + Set value means at which temperature the heating will be turned on even if the thermostat was manually set to off. The parameter can be set from 0 to 255 where 0 to 128 means from 0.0 C to 12.8 C and from 129 to 255 means from - 0.0 C to -12.8 C. + + + default value 100 (Maximum PWM value) | 2-100 = 2%-100%, step is 1%. Max. PWM set by entered value. NOTE: The maximum level may not be lower than the minimum level! + + + default value 0 (Minimum PWM value is 0%) | 1-99 = 1%-99%, step is 1%. Max. PWM set by entered value. NOTE: The Minimim level may not exceed Maximum level! + + + Default value 10 (Cycle duration set to 10s) | 5-127 = 5-127s, step is 1s. PWM cycle duration set by entered value. NOTE: PWM cycle duration define the summary of all ON plus OFF time periods. For example if Output is set to 70% with PWM cycle duration of 20s, output will be ON for 14s then OFF 6s, again 14s ON, etc + + + + When value is set to ZERO PID inside deadband is forced to zero. LASTVALUE means that PID remains on same level as was before entering into deadband + + + + + default value 5 (0,5 C) | 0-127 - 0.0 C to 12.7 C, step is 0,1C. NOTE: This parameter defines the zone where PID is not active. If the temperature difference between actual and setpoint is bigger than PID deadband, then the PID will start to regulate the system, otherwise the PID is zero or fixed + + + default value 5 (0,5 C) | 0-127 - 0.0 C to 12.7 C, step is 0,1C. NOTE: Parameter defines the time between samples. On each sample the + controller capture difference between SP-act + + + default value 100 | 0 -1000 - P value, step is 1 + + + default value 1 | 0 -1000 - I value, step is 1 + + + default value 1 | 0 -1000 - D value, step is 1 + + + default : Heat mode | Heat mode | Cool mode + + + + + Default value 50 (Too low temperature limit is 5.0C) | 1 - 1000 = 0.1C - 100.0C, step is 0.1C. Too low temperature limit is set by entered value. In case measured temperature is below set value, module sends BasicSet value. + + + Default value 700 (too high temperature limit is 70.0C) | 1 - 1000 = 0.1C - 100.0C, step is 0.1C. Too high temperature limit is set by entered value. In case measured temperature is higher than set value, module sends BasicSet value. + + + + + + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 11 must be set to 2! NOTE: Device status on UI change immediately + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 11 must be set to 2! NOTE: Device status on UI change immediately + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 12 must be set to 2000! + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 12 must be set to 2000! + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 13 must be set to 2! NOTE: Device status on UI change immediately + + + default value 0 | 1 - 32000 seconds. If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. Parameter 13 must be set to 2! NOTE: Device status on UI change immediately + + + + Enabling I1 means that Endpoint (I1) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Enabling I2 means that Endpoint (I2) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Enabling I3 means that Endpoint (I3) will be present on UI. + Disabling it will result in hiding the endpoint according to the parameter set value. + Additionally, a Notification Type and Event can be selected for the endpoint. + NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! + NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. + + + + + + + + + + + + + Set value is added or subtracted to actual measured value by sensor. + From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. + From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + Default value 32536. 32536 offset is 0.0C. + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. + 0 = reporting disabled. + 1 to 127 = 0,1C to 12,7C, step is 0,1C. + Default value is 5 = 0,5C + + + + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHNDx.xml b/openzwave/qubino/ZMNHNDx.xml new file mode 100644 index 00000000..12933211 --- /dev/null +++ b/openzwave/qubino/ZMNHNDx.xml @@ -0,0 +1,150 @@ + + + http://www.openzwave.com/device-database/0159:0053:0002 + images/qubino/ZMNHNDx.png + https://products.z-wavealliance.org/products/2536/ + • Connect module to power supply +• bring module within maximum 1 meter (3 feet) of the main controller, +• enable add/remove mode on main controller, +• press service button S for more than 6 second or +• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply. +By this function all parameters of the module are set to default values and own ID is deleted. +If service button S is pressed more than 2 and less than 6 seconds (or if push button I1 is pressed three times within 3s) module is excluded, but configuration parameters are not set to default values. + +NOTE: If the module is included with parameters 71 with value different to default and module reset is done, wait at least 30s before next inclusion. + +NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + CEPT (Europe) + The Qubino Flush Shutter DC is ideal for controlling the 12–24V DC motors of blinds, rollers, shades, venetian blinds and similar sunscreens. You can control it either remotely through the Z-Wave network or through wall switches. It also measures power consumption and supports the connection of a digital temperature sensor. + • Connect module to power supply (with +temperature sensor connected - if purchased), +• auto-inclusion (works for about 5 seconds after connected to power supply) or +• press service button S for more than 2 second or +• press push button I1 three times within 3s (3 times change switch state within 3 seconds). + +NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply. + +NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module. + + press service button S for more than 6 second or +• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply. +By this function all parameters of the module are set to default values and own ID is deleted. +If service button S is pressed more than 2 and less than 6 seconds (or if push button I1 is pressed three times within 3s) module is excluded, but configuration parameters are not set to default values. + +NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + + Flush Shutter DC + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2536/Qubino_Flush Shutter DC PLUS extended manual_eng_2.2.pdf + ZMNHOD1 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1336/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2536/xml + Enable MapRootToEndPoint in MultiChannel Class + + + + + + + + + + + + + + + + + + Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system + + + + + + + + 0 => Auto OFF disabled. + 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). + Auto OFF enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 + + + + 0 - Auto OFF disabled. + 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). + Auto ON enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 + + + + + + + + + + + + + + + + + + + Available from SW version S1 Only + This parameter defines if reporting regarding power level, multilevel, etc, are reported to controller or not. + NOTE: Disabling reporting is recommended in case Z-wave modules communicate in association groups without using main controller. + + + + + + + + + + + + + + + + + Set value is added or subtracted to actual measured value by sensor. + Available configuration parameters : default value 32536. 32536 offset is 0.0C. + From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. + From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. + Available configuration parameters : 0 = reporting disabled. 1 to 127 = 0,1C to 12,7C, step is 0,1C. Default value is 5 = 0,5C + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHODx.xml b/openzwave/qubino/ZMNHODx.xml new file mode 100644 index 00000000..233bbf5a --- /dev/null +++ b/openzwave/qubino/ZMNHODx.xml @@ -0,0 +1,175 @@ + + + http://www.openzwave.com/device-database/0159:0053:0003 + images/qubino/ZMNHODx.png + https://products.z-wavealliance.org/products/2976/ + • Connect module to power supply +• bring module within maximum 1 meter (3 feet) of the main controller, +• enable add/remove mode on main controller, +If service button S is pressed more than 2 and less than 6 seconds (or if push button I1 is pressed three times within 3s) module is excluded, but configuration parameters are not set to default values. + +NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + U.S. / Canada / Mexico + The Qubino Flush Shutter DC is ideal for controlling the 12–24V DC motors of blinds, rollers, shades, venetian blinds and similar sunscreens. You can control it either remotely through the Z-Wave network or through wall switches. It also measures power consumption and supports the connection of a digital temperature sensor. + ZMNHOD3 + • Connect module to power supply (with +temperature sensor connected - if purchased), +• auto-inclusion (works for about 5 seconds after connected to power supply) or +• press service button S for more than 2 second or +• press push button I1 three times within 3s (3 times change switch state within 3 seconds). + +NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply. + +NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module. + + Flush Shutter DC + press service button S for more than 6 second or +• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply. +By this function all parameters of the module are set to default values and own ID is deleted. + +NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2976/Qubino_Flush Shutter DC PLUS extended manual_eng_2.2.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2976/xml + + + + + + + Responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 to 100 = 1% to 100% Reporting enabled. + Power report is send (push) only when actual power (in Watts) in real time changes for more + than set percentage comparing to previous actual power in Watts, step is 1%. Default value 1 + + + Set value means time interval (0 - 32767) in seconds, when power report is send. + 0 - Reporting Disabled. + 1 - 32767) = 1second - 32767) seconds, Reporting enabled. + Power report is send with time interval set by entered value. + + + Module may include power and energy used by module itself in reports sent to the main controller + + + + + Defines selection between two available operating modes. 0 Shutter mode + 1 Venetian mode (up/down and slate tilting) + Note: When setting parameter, module needs to be reconfigured! Please check detailed description in this manual. + + + + + + + Defines the time necessary for slats to make full turn (180 degrees). + 0 Tilting time disabled + 1 to 32767 = 0,01seconds to 327,67 seconds + Note: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining. + + + + + This parameter defines slats position after up/down movement through UI or push buttons, return to previously set position only in case of + 0 - UI control. + 1 - UI control, momentary switch operation, or when the limit switch is reached. + 2 - UI control, Push button, Limit switch is reached, after receiving a STOP control frame from UI. + ( Default value 2 ) + + + + + + + + Defines shutter motor moving time of complete opening or complete closing. + 0 - moving time disabled (working with limit switches) + 1 - 32767 = 0,1seconds - 3276,7seconds. After that time motor is stopped (relay goes to off state) + See complete note in documentation. + + + + Power threshold to be interpreted when motor reach the limit switch. + Available settings: 5 to 100 (0,5 W to 10 W), step is 0,1W. + + + By modifying the parameters setting, Shutter enters the calibration mode. + (after shutter performs the calibration process, completing full cycle - up, down and up, + set the parameter value back to default. ) + + + + + + + Defines if reporting regarding power level, multilevel, etc.., are reported to controller or not. + + + + + + Defines the max time before motor power consumption is read after one of the relays is switched ON. + If there is no power consumption during this max time + (motor not connected, damaged or requires higher time to start, motor in end position,...) the relay will switch OFF. + Available settings: 3 - 50 = 0,3 seconds - 5 seconds (100ms resolution). + + + + Defines the max time at limit switch, when power consumption is below power threshold. + If the power consumption during this time is below power threshold (par. 76), the active output will switch off, means that limit switch is reached. + Available settings: 3 - 50 = 0,3 seconds - 5 seconds (100ms resolution). + + + + Defines the time delay between output relay switching (time between switching up/down and vice versa). + Available settings: 1 - 30 = 0,1 seconds - 3 seconds (100ms resolution). + + + + + From 1 to 100 - value from 0.1 C to 10.0 C is added to actual measured temperature. + From 1001 to 1100 - value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. + Available settings: 0 - Reporting disabled. + 1 - 127 = 0,1C - 12,7C, step is 0,1C. + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHQDx.xml b/openzwave/qubino/ZMNHQDx.xml new file mode 100644 index 00000000..2e2e95c1 --- /dev/null +++ b/openzwave/qubino/ZMNHQDx.xml @@ -0,0 +1,96 @@ + + + LUXY Smart Light + The Qubino LUXY Smart Light is ideal for gentle illumination of any room and for visual and sound notifications. + http://www.openzwave.com/device-database/0159:0051:0008 + https://qubino.com + https://support.qubino.com/support/home + images/qubino/ZMNHQDx.png + + Manual inclusion is triggered by the following procedure: + Full white needs to be active (c-button 2). The user can select it by quickly pressing the c-button2 once. + When full white is enabled, press c-button3 and hold it for 5 seconds (while white is glowing, hold c-button3 for 5 seconds). + After 5 seconds, the device starts flashing, with the following pattern: green 1 second on, 0.5 second off. + Once the device receives a nodeId or after 10 seconds, it stops flashing and turns green. + + + Exclusion is triggered by the following procedure: + Full white needs to be active (c-button 2). + When full white is enabled, press c-button3 and hold it for 5 seconds (while white is glowing hold c-button3 for 5 seconds). + After 5 seconds, the device starts flashing with the following pattern: red 1 second on, 0.5 second off. + Once the device loses its nodeId or after 10 seconds, it stops flashing and turns red. + + + Reset is triggered after the following procedure: + Full white needs to be active (c-button 2). + When full white is enabled, press c-button5 and hold it for 10 seconds. + After 10 seconds, the device starts flashing with the following pattern: blue 1 second on, 0.5 second off. + After 10 seconds the device stops flashing and turns blue. + The procedure is available always. + + + Initial Import + Reformat and remove small typo + Fix Empty ChangeLog Entry + Add Product Pic + + + + + + + + Defines the type of input device, connected to digital input. + + + + + + + With this parameter, you can determine, how to turn off the alarm. + + + + + + Defines the time after which the output triggered by motion sensor is turned off. + Default value = 10. + 0 to 32534 => 0-32534 seconds after which the LED will be turned off. + 32535 => never turns off. + + + + + Default value = 0 + 0 => Disabled + 30 to 32767 => 30 - 32767 seconds after which the device turns on. + + + + + Default value = 0 + 0 => Disabled + 30 to 32767 => 30 - 32767 seconds after which the device turns off. + + + + With this parameter, the user can select if the state of the device should be restored, after a power failure. + + + + + With this parameter, the user can select the operating mode of the beeper. + + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/qubino/ZMNHSDx.xml b/openzwave/qubino/ZMNHSDx.xml new file mode 100644 index 00000000..066509c7 --- /dev/null +++ b/openzwave/qubino/ZMNHSDx.xml @@ -0,0 +1,174 @@ + + + http://www.openzwave.com/device-database/0159:0052:0001 + images/qubino/ZMNHSDx.png + https://products.z-wavealliance.org/products/2252/ + CEPT (Europe) + • Press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + • Connect module to power supply (with +temperature sensor connected - if purchased), +• enable add/remove mode on main controller +• auto-inclusion (works for about 5 seconds after connected to power supply) or +• press service button S for more than 2 second or +• press push button I1 three times within 3s (3 times change switch state within 3 seconds). + +NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply. +NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2252/Qubino_DIN Dimmer PLUS extended manual_eng_2.3.pdf + DIN Dimmer + DIN Dimmer is a DIN rail mounted dimmer for light bulbs. You can control it either remotely through the Z-Wave network or through wall switches. It also measures power consumption and supports the connection of a digital temperature sensor. + ZMNHSD1 + • Connect module to power supply +• bring module within maximum 1 meter (3 feet) of the main controller, +• enable add/remove mode on main controller, +• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. +By this function all parameters of the module are set to default values and own ID is deleted. +If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values. + +NOTE 1: If the module is included with parameter 1 value 3, 4 or 5 and module reset is done, wait at least 30s before next inclusion. + +NOTE 2: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2252/xml + + + + + + + + + + + + + Default value 0 + + + + + Flush dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + Default value 255. + + + + + + + 0 - Auto OFF disabled. + 1 second to 32536 seconds Auto OFF enabled with defined time, step is 1 second. + Default value 0. + + + 0 - Auto ON disabled. + 1 second to 32535 seconds Auto ON enabled with defined time, step is 1 second. + Default value 0. + + + If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value. + Default value 0. + + + + + Default value 0. + + + + + Set value from 0 - 100 (0% - 100%). + 0 - Reporting Disabled. + 1 - 100 = 1% - 100% Reporting enabled. + Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. + Default value 5. + + + Set value means time interval (0 - 32767) in seconds, when power report is send. + 0 - Reporting Disabled. + 1 second to 32767 seconds reporting enabled. + Power report is send with time interval set by entered value. + Default value 300 (power report in Watts is send each 300s). + + + 1 - 98 = 1% - 98%, step is 1%. Minimum dimming values is set by entered value. + Default value 1 (Minimum dimming value is 1%). + + + 2 - 99 = 2% - 99%, step is 1%. Maximum dimming values is set by entered value. + Default value 99 (Maximum dimming value is 99%). + + + Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through. + 1- 255 = 10mseconds - 2550mseconds (2,55s), step is 10mseconds. + Default value 100 (Dimming time between min. and max. dimming values is 1s). + + + Time of moving the Dimmer between min. and max dimming values by continues hold of push button I1. + 1- 255 = 1 second - 255 seconds. + Default value 3 (Dimming time between min. and max. dimming values is 3s). + + + This parameter is used with association group 4. + A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. + A receiving device MUST ignore the start level if the Ignore Start Level bit is 1. + Default value 0. + + + + + This parameter is used with association group 3. + The Duration field MUST specify the time that the transition should take from the current value to the new target value. + A supporting device SHOULD respect the specified Duration value. + Default value 0. + + + + + Set value is added or subtracted to actual measured value by sensor. + 32536 : offset is 0.0C. + From 1 to 100 : value from 0.1 C to 10.0 C is added to actual measured temperature. + From 1001 to 1100 : value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + Default value 32536. + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. + 0 : Reporting disabled. + 1- 127 = 0,1C - 12,7C, step is 0,1C. + Default value 5 = 0,5C change. + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHTDx.xml b/openzwave/qubino/ZMNHTDx.xml new file mode 100644 index 00000000..1b541bf4 --- /dev/null +++ b/openzwave/qubino/ZMNHTDx.xml @@ -0,0 +1,208 @@ + + + http://www.openzwave.com/device-database/0159:0052:0007 + images/qubino/ZMNHTDx.png + https://products.z-wavealliance.org/products/3018/ + FACTORY RESET +1. Connect the device to the power supply +2. Press and hold the S service button between 6 seconds and 20 seconds +3. Device will be removed from you network +ⓘ By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted. Use this reset procedure only when the main gateway (hub) is missing or otherwise inoperable. + + The Qubino Smart Meter can be used in residential, industrial and utility applications. It measures energy directly in 2-wire networks by means of fast sampling of voltage and current signals. It calculates energy, power and power factor from the measured signals. You can control the device through the Z-Wave network. +The Qubino Smart Meter can operate across a wide temperature range, from a chilly -15˚C to a scorching 55˚C (5˚F–131˚F). Every device also acts as a repeater in order to improve the range and stability of the Z-Wave network. + Smart Meter + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3018/Qubino_Smart Meter PLUS extended manual_eng_2.3.pdf + ZMNHTD1 + AUTOMATICALLY ADDING THE DEVICE TO A Z-WAVE NETWORK (AUTO INCLUSION) +1. Enable add/remove mode on your Z-Wave gateway (hub) +2. Automatic selection of secure/unsecure inclusion +3. The device can be automatically added to a Z-Wave network during the first 2 minutes +4. Connect the device to the power supply +5. Auto-inclusion will be initiated within 5 seconds of connection to the power supply and the device will automatically enrol in your network +ⓘ NOTE: For S2 inclusion please check chapter – »16. Z-Wave Security«. +MANUALLY ADDING THE DEVICE TO A Z-WAVE NETWORK (MANUAL INCLUSION) +1. Connect the device to the power supply +2. Enable add/remove mode on your Z-Wave gateway (hub) +2. Toggle the Service button S between 0.2 and 6 seconds +3. A new multi-channel device will appear on your dashboard + + CEPT (Europe) + REMOVAL FROM A Z-WAVE NETWORK (Z-WAVE EXCLUSION) +1. Connect the device to the power supply +2. Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion +3. Enable add/remove mode on your Z-Wave gateway (hub) +4. Press and hold the S service button between 0.2 and 6 seconds +5. The device will be removed from your network but custom configuration parameters will not be erased + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3018/xml + Add MapRootToEndpoints and Instance Labels. Note - You will get a Timeout Message when getting a MultiChannelAssociation Get Message. Qubino are aware of this issue. It should not affect the operation of the device. + + + + + + + + Default value 4 + + + + + + + + Smart meter module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + Default value 255. + + + + + + + + 0 - Auto OFF disabled. + 1 second to 32536 seconds Auto OFF enabled with defined time, step is 1 second. + Default value 0. + + + + 0 - Auto ON disabled. + 1 second to 32535 seconds Auto ON enabled with defined time, step is 1 second. + Default value 0. + + + + 0 - Auto OFF disabled. + 1 second to 32536 seconds Auto OFF enabled with defined time, step is 1 second. + Default value 0. + + + + 0 - Auto ON disabled. + 1 second to 32535 seconds Auto ON enabled with defined time, step is 1 second. + Default value 0. + + + + Set value from 0 - 100 (0% - 100%). + 0 - Reporting Disabled. + 1 - 100 = 1% - 100% Reporting enabled. + Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. + Default value 10. + + + + Set value means time interval (0 - 32767) in seconds, when power report is send. + 0 - Reporting Disabled. + 1 second to 32767 seconds reporting enabled. + Power report is send with time interval set by entered value. + Default value 0. + + + + Default value 0 + + + + + + + + Enabling IR external relay and External relay or both of them, means that endpoint (IR external relay) and endpoint (External relay) or both will be prensent on UI. + Disabling them will result in hiding endpoints according to parameter set value.Note that hiding endpoint has no impact on its functionality. + Default value 0 + + + + + + + + 0 - Pmax auto OFF disabled. + 1W to 15000W Auto OFF enabled, step is 1 Watt. Linked with param 111/112. + Default value 0 (disabled). + + + + 30s to 32535s Auto OFF time, step is 1 sec, if param 110 pMax is reached. + Default value 30. + + + + Switch OFF IR external relay and/or External relay or both of them, if param 110 pMax is reached. + Default value 0. + + + + + + + + Returns device S/N. + + + Returns device FW version. + + + Returns device HW version. + + + Returns U1 in deci-Volts. + + + Returns I1 in milli-Amp. + + + Returns Pt in deci-Watt. + + + Returns Qt in deci-kVAR. + + + Returns PFt(x1000). + + + Return Pin in deci-kWh. + + + Returns Qin in deci-kVARh. + + + Returns Pt in deci-kVAh. + + + Return Pout in deci-kWh. + + + + + + + + + + + true + + + + + + + true + + + + + + diff --git a/openzwave/qubino/ZMNHTDxS3.xml b/openzwave/qubino/ZMNHTDxS3.xml new file mode 100644 index 00000000..df984e5b --- /dev/null +++ b/openzwave/qubino/ZMNHTDxS3.xml @@ -0,0 +1,119 @@ + + + + + + + + + Default value 4 + + + + + + + + + Smart meter module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + Default value 255. + + + + + + + + 0 - Auto OFF disabled. + 1 second to 32536 seconds Auto OFF enabled with defined time, step is 1 second. + Default value 0. + + + + 0 - Auto ON disabled. + 1 second to 32535 seconds Auto ON enabled with defined time, step is 1 second. + Default value 0. + + + + 0 - Auto OFF disabled. + 1 second to 32536 seconds Auto OFF enabled with defined time, step is 1 second. + Default value 0. + + + + 0 - Auto ON disabled. + 1 second to 32535 seconds Auto ON enabled with defined time, step is 1 second. + Default value 0. + + + + Set value from 0 - 100 (0% - 100%). + 0 - Reporting Disabled. + 1 - 100 = 1% - 100% Reporting enabled. + Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. + Default value 10. + + + + Set value means time interval (0 - 32767) in seconds, when power report is send. + 0 - Reporting Disabled. + 1 second to 32767 seconds reporting enabled. + Power report is send with time interval set by entered value. + Default value 0. + + + + Default value 0 + + + + + + + + + Enabling IR external relay and External relay or both of them, means that endpoint (IR external relay) and endpoint (External relay) or both will be prensent on UI. + Disabling them will result in hiding endpoints according to parameter set value.Note that hiding endpoint has no impact on its functionality. + Default value 0 + + + + + + + + + + + + + + + + + + + + + true + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHUD1.xml b/openzwave/qubino/ZMNHUD1.xml new file mode 100644 index 00000000..698bcf69 --- /dev/null +++ b/openzwave/qubino/ZMNHUD1.xml @@ -0,0 +1,57 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHVDx.xml b/openzwave/qubino/ZMNHVDx.xml new file mode 100644 index 00000000..faf3e6b8 --- /dev/null +++ b/openzwave/qubino/ZMNHVDx.xml @@ -0,0 +1,232 @@ + + + http://www.openzwave.com/device-database/0159:0053:0001 + images/qubino/ZMNHVDx.png + https://products.z-wavealliance.org/products/2241/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2241/Qubino_Flush Dimmer 0-10V PLUS extended manual_eng_2.2.pdf + • Press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + Qubino Flush Dimmer 0-10V + The Qubino Flush Dimmer 0-10V is a universal dimmer with a standard 0-10V output and a multi-function input, which may be a push button or switch, a potentiometer or a 0-10V signal. It also measures power consumption and supports the connection of a digital temperature sensor. + + + + • Connect module to power supply +• bring module within maximum 1 meter (3 feet) of the main controller, +• enable add/remove mode on main controller, +• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or +• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second. +By this function all parameters of the module are set to default values and own ID is deleted. +If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values. + +NOTE 1: If the module is included with parameter 1 value 3, 4 or 5 and module reset is done, wait at least 30s before next inclusion. + +NOTE 2: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + CEPT (Europe) / Australia / New Zealand / U.S. / Canada / Mexico + ZMNHVD3 + • Connect module to power supply (with +temperature sensor connected - if purchased), +• enable add/remove mode on main controller +• auto-inclusion (works for about 5 seconds after connected to power supply) or +• press service button S for more than 2 second or +• press push button I1 three times within 3s (3 times change switch state within 3 seconds). + +NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply. +NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2196/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2216/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2241/xml + + + + + + + NOTE: After parameter change to value 3, 4 or 5 first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module! + + + + + + + + + Responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. + + + + + + + 0 => Auto OFF disabled. 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). Auto OFF enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 + + + 0 - Auto OFF disabled. 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). Auto ON enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 + + + + + + + + + + + + + + This parameter is influencing on the software only when the value of parameter number 1 is set to value 3, 4 or 5. + In manual mode regulation (how the input influence on output) is disabled. + + + + + + + NOTE: When ZERO PID inside deadband is forced to zero. + Last value means that PID remains on same level as was before entering into deadband. + + + + + + + 0 to 100 => 0 to 100%, step is 1%. + Default value 1. + NOTE: This parameter defines the zone where PID is not active. If the temperature difference between actual and setpoint is bigger than PID deadband, then the PID will start to regulate the system, otherwise the PID is zero or fixed. + + + + + 0 to 127 => 0 to 127s, step is 1s. + Default value 1. + Parameter defines the time between samples. On each sample the controller capture difference between SP-act. + + + + + 0 to 1000, step is 1. + Default value 100. + + + + + 0 to 1000, step is 1. + Default value 1. + + + + + 0 to 1000, step is 1. + Default value 1. + + + + 1 - 98 = 1% - 98%, step is 1%. Minimum dimming values is set by entered value. + Default value 1 (Minimum dimming value is 1%). + + + 2 - 99 = 2% - 99%, step is 1%. Maximum dimming values is set by entered value. + Default value 99 (Maximum dimming value is 99%). + + + Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through. + 1- 255 = 10mseconds - 2550mseconds (2,55s), step is 10mseconds. + Default value 100 (Dimming time between min. and max. dimming values is 1s). + + + Time of moving the Dimmer between min. and max dimming values by continues hold of push button I1. + 1- 255 = 1 second - 255 seconds. + Default value 3 (Dimming time between min. and max. dimming values is 3s). + + + This parameter is used with association group 4. + A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. + A receiving device MUST ignore the start level if the Ignore Start Level bit is 1. + Default value 0. + + + + + This parameter is used with association group 3. + The Duration field MUST specify the time that the transition should take from the current value to the new target value. + A supporting device SHOULD respect the specified Duration value. + Default value 0. + + + + + + From 1 to 100 - value from 0.1 C to 10.0 C is added to actual measured temperature. + From 1001 to 1100 - value from -0.1 C to -10.0 C is subtracted to actual measured temperature. + + + + If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. + Available settings: 0 - Reporting disabled. + 1 - 127 = 0,1C - 12,7C, step is 0,1C. + + + + + If analogue sensor is connected, module reports measured value on change defined by this parameter. + 0 - Reporting disabled. + 1 to 10000, step is 0.1. + Default value 5 => 0.5C. + + + + Parameter is associated with Association group No. 2. + Below this value, the Association No. 2 will report Basic Set 0xFF and above this value will report Basic Set 0xFF. + Basic Set is reported only, when the input value changes for more than 10% (1V). + Default setting: 5 (0.5V) + 1 to 100 => (0,1 to 10V) + + + + + Value that must correspond to minimum sensor range value. + Valid only if parameter 1 is set to values 3, 4 or 5). + default value 0 = 0.0C / 0Lux / 0.0%rh + 0 to 10000 => value from 0 to 1000 (resolution 0,1) + 10001 to 20000 => value from -0,1 to -1000 (resolution 0,1) + NOTE: Minimum value must not be higher than maximum value! + + + + + Value that must correspond to maximum sensor range value. + Valid only if parameter 1 is set to values 3, 4 or 5). + default value 1000 = 100.0C / 100Lux / 100.0%rh + 0 to 10000 => value from 0 to 1000 (resolution 0,1) + 10001 to 20000 => value from -0,1 to -1000 (resolution 0,1) + NOTE: Maximum value must not be lower than minimum value! + + + + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHWD1.xml b/openzwave/qubino/ZMNHWD1.xml new file mode 100644 index 00000000..24b85c41 --- /dev/null +++ b/openzwave/qubino/ZMNHWD1.xml @@ -0,0 +1,157 @@ + + + http://www.openzwave.com/device-database/0159:0054:0001 + images/qubino/ZMNHWD1.png + https://products.z-wavealliance.org/products/2552/ + FACTORY RESET +1. Connect the module to the power supply +2. Press and hold the S (Service) button for at least 10 seconds +NOTE: By resetting the module, all custom parameters previously set on the module will return to their default values, and owner ID will be deleted. Use this reset procedure only when the main controller is missing or otherwise inoperable. + 1. Connect the module to the power supply +2. Make sure the module is within direct range of your Z-Wave controller or use a hand-held Z-Wave remote to perform exclusion +3. Press and release the S (Service) button 3 times within 2 seconds +NOTE: The module will be excluded from your network, but any custom configuration parameters will not be erased. + Flush RGBW Dimmer Switch Color R.G.B.W + Flush RGBW Dimmer / ZMNHWD3 + 1. Connect the module to the power supply +2. Enable inclusion mode on your Z-Wave controller +3. Press and release the S (Service) button 3 times within 2 seconds + Qubino Flush RGBW module is used to control RGB/RGBW strips and LED strips or bulbs to create countless colour options and has 5 special scene effects. It can also control halogen lights and fans. Its extremely small size allows for easy installation behind wall sockets and switches. Controlled devices may be powered by 12 or 24 VDC. All IN and OUT terminals may be user configured for LED control or 100 kΩ signal readouts. + CEPT (Europe) / U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2552/Qubino_Flush RGBW Dimmer PLUS extended manual_eng_2.2.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2174/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2552/xml + Add missing parameters and fix exiting + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + This parameter is used to adjust time between 2 Colours in the Scene. + 1-127 – delay duration is 1 sec to 127 sec. + 1001-1127 – delay duration is from 1 min to 127 min. This parameter has no effect on lighting and Party Scene. + + + Device will be set to status memorized before power cut. + + + + + + Output is turned automatically off after the time, set in this parameter. + 0 – Auto OFF disabled. + 1 – 32536 = 1 second – 32536 seconds Auto OFF. + + + + + Output is turned automatically on after the time, set in this parameter. + 0 – Auto ON disabled. + 1 – 32536 = 1 second – 32536 seconds Auto ON. + + + + + + + NOTE: The minimum level may not be higher than the MAX dimming value. + + + + Default value 10 = 1 s. + 5–25 = from 0.5 to 2.5 seconds + + + + 1–127 = from 1 to 127 seconds. + NOTE: Dimming time depends also on Min and Max dimming value. + + + + + NOTE: If the parameter no. 14 is enabled, parameter no. 1,2,3,4 has no effect. + NOTE: After parameter change, first exclude device (without setting parameters to default value) and then re include the device. + + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNHXDx.xml b/openzwave/qubino/ZMNHXDx.xml new file mode 100644 index 00000000..609e8f5d --- /dev/null +++ b/openzwave/qubino/ZMNHXDx.xml @@ -0,0 +1,79 @@ + + + 3-PHASE SMART METER + USER MANUAL EN.QUBINO 3-PHASE SMART METERThe Qubino 3-Phase Smart Meter is an extremely versatile and powerful Z-Wave devicefor measuring energy in a three-phase electrical power network of up to 3 x 65A. + http://www.openzwave.com/device-database/0159:0007:0054 + https://qubino.com/products/3-phase-smart-meter/ + https://qubino.com/support/ + images/qubino/zmnhxdx.png + https://qubino.com/wp-content/uploads/2019/06/Qubino_3-Phase-Smart-Meter-PLUS-extended-manual_eng_3.4.pdf?cf_id=2255 + Toggle the Service button S between 0.2 and 3seconds + Press and hold the S service button between 0.2 and 3seconds + Press and hold the S service button between 6 seconds and 20 seconds + CEPT (Europe) + ZMNHXDx + + Update to Support OZW 1.6 with Instance Label Names + + + + + + + + + + + + + + This parameter is valid for Active Power Total, Active Power Phase1, Active Power Phase2 and Active Power Phase3. Set value means percentage from 0-100 = 0% - 100% + + + This parameter is currently valid only for Active Energy Total Import/Export (kWh), Reactive Energy Total (kvarh), Total Energy (kVAh) + + + This parameter is valid only for Voltage (V of ph1, ph2, ph3), Current (A of ph1, ph2, ph3), Total Power Factor, Total Reactive Power (var) + + + + + + + + + + + + + + This parameter defines a threshold when External IR relay is being turned off. (If Parameter no. 100 is set to the value 1 or 2) + + + This parameter defines a threshold when External relay is being turned off (if the parameter no. 100 is set to the value 1 or 2). + + + External IR relay/ External relay is turned off due to detected overload (as set by parameter 106 and 107) and remains off for a time, defined in this parameter. After that time, the output turns on to check, if the overload is still present. + + + + + + + + + + + + + + true + + + + + + + + + diff --git a/openzwave/qubino/ZMNHYDx.xml b/openzwave/qubino/ZMNHYDx.xml new file mode 100644 index 00000000..64f9c623 --- /dev/null +++ b/openzwave/qubino/ZMNHYDx.xml @@ -0,0 +1,158 @@ + + + http://www.openzwave.com/device-database/0159:0054:0002 + images/qubino/ZMNHYDx.png + https://products.z-wavealliance.org/products/3146/ + Smart Plug 16A + CEPT (Europe) + FACTORY RESET +• The reset is only possible the first minute after the power on +• Press and hold the service button S more than 6 seconds +• The device will be removed from your network and the led will start blinking. The device is now in its factory default state. +• When the S button is held more than 6 seconds after the first minute is passed, the relay should not react! + +By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted. Use this reset procedure only when the main gateway (hub) is missing or otherwise inoperable. + The Smart Plug 16A controls on/off function for the connected device. It also measures power consumption of the connected device according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates energy and power from the measured signals. + AUTOMATICALLY ADDING THE DEVICE TO A Z-WAVE NETWORK (AUTO INCLUSION) +1. Enable add/remove mode on your Z-Wave gateway (hub) +2. Automatic selection of secure/unsecure inclusion +3. The device can be automatically added to a Z-Wave network during the first 2 minutes +4. Connect the device to the power supply +5. Auto-inclusion will be initiated within 5 seconds of connection to the power supply and the device will automatically enrol in your network (when the device is excluded and connected to the power supply it automatically enters the INCLUSION MODE state.) + ZMNHYD1 + REMOVAL FROM A Z-WAVE NETWORK (Z-WAVE EXCLUSION) +1. Connect the device to the power supply +2. Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion +3. Enable add/remove mode on your Z-Wave gateway (hub) +4. Press and hold the Service button S from 2 to 6 seconds (with holding the S button for the interval between 2 and 6 seconds you put the device in EXCLUSION MODE) +5. The device will be removed from your network, but any custom configuration parameters will not be erased + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3146/Qubino_Smart Plug 16A PLUS extended manual_eng_2.5.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3146/xml + Update description for configuration parameter 52 and fix typo + + + + + + + + Smart Meter module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system + + + + + + + + If Smart plug 16A is ON, you can schedule it to turn OFF automatically after a period of time defined in this parameter. + The timer is reset to zero each time the device receives an ON command, either remotely (from the gateway (hub) or associated device) or locally from the switch. + 0 => Auto OFF disabled. + 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). + Auto OFF enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 + + + + + If Smart plug 16A is OFF, you can schedule it to turn ON automatically after a period of time defined in this parameter. + The timer is reset to zero each time the device receives an OFF command, either remotely (from the gateway (hub) or associated device) or locally from the switch. + 0 - Auto OFF disabled. + 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). + Auto ON enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 + + + + + Choose if you want to set the timer in seconds or milliseconds in parameters 11 and 12. + + + + + + + This parameter determines if on/off status is saved and restored for the Smart plug 16A after power failure. + + + + + + + Choose by how much power consumption needs to increase or decrease to be reported. Values correspond to percentages so if 20 is set (by default), the device will report any power consumption changes of 20% or more compared to the last reading. + Set value from 0 - 100 (0% - 100%). + 0 - Reporting Disabled. + 1 - 100 = 1% - 100% Reporting enabled. + Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. + Default value 20. + + + + Set value refers to the time interval with which power consumption in Watts is reported (0 - 32535 seconds). + If 300 is entered (by default), energy consumption reports will be sent to the gateway (hub) every 300 seconds (or 5 minutes). + Set value means time interval (0 - 32767) in seconds, when power report is send. + 0 - Reporting Disabled. + 1 second to 32767 seconds reporting enabled. + Power report is send with time interval set by entered value. + Default value 300 (power report in Watts is send each 300s). + + + + + Lower power threshold used in param 52. + Can not be higher than param 51 + 0-4000 (0.0 to 4000.0W, 0 disables) + + + + + Upper power threshold used in param 52. + Can not be higher than param 50 + 0-4000 (0.0 to 4000.0W, 0 disables) + + + + + Parameter defines the way 3rd association group devices are controlled, depending on the current power load. + + + + + + + + + + + + The function allows for turning off the controlled device in case of exceeding the defined power for more than 3.1s. + Controlled device can be turned back on by S-button or sending a control frame. By default this function is inactive. + 1-4000 (1-4000W) 0 disables + + + + + Using this parameter it is possible to enable/disable reporting after the set command (i.e. Basic set). + + + + + + + + + + + + + + + + + + diff --git a/openzwave/qubino/ZMNHZDx.xml b/openzwave/qubino/ZMNHZDx.xml new file mode 100644 index 00000000..9540c04f --- /dev/null +++ b/openzwave/qubino/ZMNHZDx.xml @@ -0,0 +1,141 @@ + + + + + false + + + + + + true + + + + + + + If the Wind Gust is Higher than the Parameter Value, a device triggers an Association. + 0 to 8800 = value from 0.00 m/s to 88.00 m/s. + Default value 1000 (10,00 m/s). + + + + + If the Sensor Rain Rate is Higher than the Parameter Value, a device triggers an Association. + 0 to 30000 = value from 0.00 mm/h to 300.00 mm/h. + Default value 200 (2,00 mm/h). + + + + If the Wind Gust is Higher than the Parameter No. 1 Value, then a Device sends Basic Set + + + + + If the Rain amount is Higher than the Parameter No. 2 Value, then a Device sends Basic Set + + + + + If you enable Unsolicited Reports on the End Points, the USB Key will send data to the controller every time it receives data from the 433MHz sensors, which are different from the precious data. + + + + + If you enable Unsolicited Reports on the End Points, the USB Key will send data to the controller every time it receives data from the 433MHz sensors, which are different from the precious data. + + + + + If you enable Unsolicited Reports on the End Points, the USB Key will send data to the controller every time it receives data from the 433MHz sensors, which are different from the precious data. + + + + + If you enable Unsolicited Reports on the End Points, the USB Key will send data to the controller every time it receives data from the 433MHz sensors, which are different from the precious data. + + + + + If you enable Unsolicited Reports on the End Points, the USB Key will send data to the controller every time it receives data from the 433MHz sensors, which are different from the precious data. + + + + + If you enable Unsolicited Reports on the End Points, the USB Key will send data to the controller every time it receives data from the 433MHz sensors, which are different from the precious data. + + + + + If you enable Unsolicited Reports on the End Points, the USB Key will send data to the controller every time it receives data from the 433MHz sensors, which are different from the precious data. + + + + + If you enable Unsolicited Reports on the End Points, the USB Key will send data to the controller every time it receives data from the 433MHz sensors, which are different from the precious data. + + + + + If you enable Unsolicited Reports on the End Points, the USB Key will send data to the controller every time it receives data from the 433MHz sensors, which are different from the precious data. + + + + + If you enable Unsolicited Reports on the End Points, the USB Key will send data to the controller every time it receives data from the 433MHz sensors, which are different from the precious data. + + + + + + If Random ID is disabled, the Weather Station USB Key can receive data from multiple 433 MHz Sensors on the same Channel. + If the Random ID is enabled, the USB Key can receive data from only one sensor on the same channel. + If the USB Key does not receive a data from a sensor on a specific channel for more than 2.5 hours, it clears the Random ID of the device and waits for a new ID. + If you replace the batteries in the modules, the Random ID will change. + If you want that the USB Key accept a module immediately, set the Parameter No. 15 to 0 and in the next step again to 1. + + + + + + + The Weather Station Key supports both, the secure and unsecure inclusion. + Even if the controller does not support security command classes, the Key could be included as unsecure and keep all the functionality. + By default, the Key includes as insecure. To include the Key as secure follow the procedure: + 1. Include the Key into the controller. + 2. Set the parameter 250 to the value 1. + 3. Enable add/remove mode on main controller. + 4. Hold service button S between 1.5 and 4 seconds to exclude the module. + 5. If the exclusion of the module was successful, the LED on the module starts blinking. + 6. Unplug the module out of the power supply. + 7. enable add/remove mode on main controller. + 8. Plug the module into the power supply to star auto-inclusion. + 9. Now the module should be included as secure. + The same procedure is to include the module as unsecure. + + + + + + + + + + + + + + + + true + + + diff --git a/openzwave/qubino/ZMNKADx.xml b/openzwave/qubino/ZMNKADx.xml new file mode 100644 index 00000000..3f0839d8 --- /dev/null +++ b/openzwave/qubino/ZMNKADx.xml @@ -0,0 +1,171 @@ + + + LUXY Smart Switch + The Qubino LUXY Smart Switch is ideal for gentle illumination of any room, for visual and sound notifications, and for controling various loads, using the built-in relay. + http://www.openzwave.com/device-database/0159:0052:0008 + https://qubino.com + https://support.qubino.com/support/home + images/qubino/ZMNKADx.png + + Manual inclusion is triggered by the following procedure: + Full white needs to be active (c-button 2). The user can select it by quickly pressing the c-button2 once. + When full white is enabled, press c-button3 and hold it for 5 seconds (while white is glowing, hold c-button3 for 5 seconds). + After 5 seconds, the device starts flashing, with the following pattern: green 1 second on, 0.5 second off. + Once the device receives a nodeId or after 10 seconds, it stops flashing and turns green. + + + Exclusion is triggered by the following procedure: + Full white needs to be active (c-button 2). + When full white is enabled, press c-button3 and hold it for 5 seconds (while white is glowing hold c-button3 for 5 seconds). + After 5 seconds, the device starts flashing with the following pattern: red 1 second on, 0.5 second off. + Once the device loses its nodeId or after 10 seconds, it stops flashing and turns red. + + + Reset is triggered after the following procedure: + Full white needs to be active (c-button 2). + When full white is enabled, press c-button5 and hold it for 10 seconds. + After 10 seconds, the device starts flashing with the following pattern: blue 1 second on, 0.5 second off. + After 10 seconds the device stops flashing and turns blue. + The procedure is available always. + + + Initial Import + Add Product Pic + + + + + + + + + Relay contact type. + + + + + + + + With this parameter, you can determine, how to turn off the alarm. + + 0 => only by z-wave command (basic set, switch multilevel set, switch multilevel start/stop level change, sound switch play tone, sound switch + configuration, switch color set, switch color start/stop level change, notification report idle) + + 1 => capacitive input (up, down, left, right) or z-wave command (basic set, switch multilevel set, switch multilevel start/stop level change, sound + switch play tone, sound switch configuration, switch color set, switch color start/stop level change, notification report idle) + + + + + + + + Default value = 0 + 0 => Disabled + 30 to 32535 => 30 - 32535 seconds after which the device turns on. + + + + + + Default value = 0 + 0 => Disabled + 30 to 32535 => 30 - 32535 seconds after which the device turns off. + + + + + + Default value = 0 + 0 => Disabled + 30 to 32535 => 30 - 32535 seconds after which the device turns on. + + + + + + Default value = 0 + 0 => Disabled + 30 to 32535 => 30 - 32535 seconds after which the device turns off. + + + + + + With this parameter, the user can select if the state of the device (color, brightness) should be restored, after a power failure. + + Default value = 1 + 1 – Enabled (the device will restore state on power failure) + 0 – Disabled (the device will not restore state on power failure and will remain off) + + + + + + + + With this parameter, the user can select if the state of the built-in relay should be restored, after a power failure. + + Default value = 1 + 1 – Enabled (the device will restore state on power failure) + 0 – Disabled (the device will not restore state on power failure and will remain off) + + + + + + + + Choose by how much the power consumption needs to increase or decrease to be reported. + Values correspond to percentages, so if 10 is set (by default), the device will report any power consumption changes of 10% or more compared to the last reading. + + Default value = 10 + 0 => Power consumption reporting disabled + 1 to 100 => 1% - 100% Power consumption reporting enabled. + + New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible). + NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported, REGARDLESS of percentage set in this parameter. + + + + + + Set value refers to the time interval for power consumption reporting (Watts). + + Default value = 0 + 0 => Power consumption reporting disabled + 30 to 32535 => 30 - 32535 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here. + + + + + + The function allows turning off the controlled device in case of exceeding the defined power for more than 5s. + The controlled device can be turned back on by input I1 or by sending an actuation command. + + Default value = 2300 + 0 => function not active + 1 to 2300 => 1 W – 2300W + + NOTE: This functionality is not an overload safety protection, please check the technical specifications chapter for more details in the official manual. + + In case of an overload event, the device will send the following message to the gateway/controller: + NOTIFICATION_REPORT_V8(type=0x08=POWER_MANAGEMENT, event=0x08=Overload detected) + + + + + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/qubino/ZMNKIDx.xml b/openzwave/qubino/ZMNKIDx.xml new file mode 100644 index 00000000..069940a1 --- /dev/null +++ b/openzwave/qubino/ZMNKIDx.xml @@ -0,0 +1,170 @@ + + + + + 0 + + + + + + + With this parameter, you can select between push-button (momentary) and on/off toggle switch types. + Default value: 1. + + + + + + + This parameter determines how the switch or push-button is connected. + Default value: 0. + + + + + + + Choose by how much power consumption needs to increase or decrease to be reported. Values correspond to percentages so if 10 is set, for example, the device will report any power consumption changes of 10% or more compared to the last reading. + Values (size is 1 byte dec): + default value 10 + 0 - Power consumption reporting disabled + 1 - 100 = 1% - 100% Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible). + NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported, REGARDLESS of percentage set in this parameter. + + + + + Set value refers to the time interval with which power consumption in Watts is reported (30 - 32767 seconds). If for example 300 is entered, energy consumption reports will be sent to the gateway (hub) every 300 seconds (or 5 minutes). + Values (size is 2 byte dec): + default value 0 (power report is disabled) + 0 - Power consumption reporting disabled + 30 - 32767 = 30 - 32767 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here. + + + + + This parameter defines minimum temperature difference between real measured temperature and set-point temperature to turn device on in heat mode or turn device off in cool mode. + Values (size is 2 byte dec): + default value 5 (0.5 C) + 0 - 450 + NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 0 - 250 (0.0 C - 25.0 C, resolution 0.1 C) + NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 0 - 450 (0.0 F - 45.0 F, resolution 0.1 F) + NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. + + + + + This parameter defines minimum temperature difference between real measured temperature and set-point temperature to turn device off in heat mode or turn device on in cool mode. + Values (size is 2 byte dec): + default value 5 (0.5 C) + 0 - 450 + NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 0 - 250 (0.0 C - 25.0 C, resolution 0.1 C) + NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 0 - 450 (0.0 F - 45.0 F, resolution 0.1 F) + NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. + + + + + Set value determines at which temperature the device will be turned on even (if the thermostat was manually set to off). + Values (size is 2 byte dec): + default value 50 (5.0 C) + -125 - 545 + 1000 - Antifreeze functionality disabled + NOTE1: Antifreeze is activated only in heating mode and it uses hysteresis of +-0.5C. + NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is -125 - 125 (-12.5 C - 12.5 C, resolution 0.1 C) + NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 95 - 545 (9.5 F - 54.5 F, resolution 0.1 F) + NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. + + + + + This parameter determines how the switch or push-button is connected. + Default value: 0. + + + + + + + This parameter determines the temperature at which the device sends a command to the associated device - to turn ON device or to turn OFF device. + Values (size is 2 byte dec): + Default value 50 (Too low temperature limit is 5.0 C) + -150 - 2120 + NOTE1: Too low temperature limit is used with Association Group 3. + NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is -150 - 1000 (-15.0 C - 100.0 C, resolution 0.1 C) + NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 50 - 2120 (5.0 F - 212.0 F, resolution 0.1 F) + NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. + + + + + This parameter determines the temperature at which the device sends a command to the associated device, to turn ON device or to turn OFF device. + Values (size is 2 byte dec): + default value 700 (too high temperature limit is 70.0 C) + 1 - 2120 + NOTE1: Too high temperature limit is used with Association Group 3. + NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 1 - 1000 (0.1 C - 100.0 C, resolution 0.1 C) + NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 322 - 2120 (32.2 F - 212.0 F, resolution 0.1 F) + NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. + + + + + Set value determines the type of the device connected to the on/off output. The output type can be normally open (NO) or normally closed (NC). + Default value: 0. + + + + + + + This parameter determines in which measurement unit the device will report temperature (Fahrenheit or Celsius) and determines the scale the configuration parameters (43, 44, 44, 45, 60, 61, 110, 120) are interpreted as. + NOTE1: This scale has influence on Temperature reporting. The device is capable of receiving a Set point in all supported scales. + NOTE2: This configuration parameter has impact on configuration parameters 43, 44, 44, 45, 60, 61, 110, 120. If scale is set to degrees Fahrenheit configuration values at parameters 43, 44, 44, 45, 60, 61, 110, 120 will be converted to degrees Celsius. Please note that converted values could drift when converting values back and forth. + Default value: 0. + + + + + + + Set value is added to or subtracted from the actually measured value to adjust the temperature report sent by an external sensor. + NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is -150 - 150 (-15.0 C - 15.0 C, resolution 0.1 C) + NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is -270 - 270 (-27.0 F - 27.0 F, resolution 0.1 F) + NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. + Default value: 0. + + + + + This configuration parameters sets reporting threshold between reported temperature and actual temperature for reporting temperature at association group 4. + NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 0 - 150 (0 C - 15.0 C, resolution 0.1 C) + NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is 0 - 270 (0 F - 27.0 F, resolution 0.1 F) + NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth. + Default value: 5. + + + + + + + + + + + + + + + + + + diff --git a/openzwave/quby/qb2.xml b/openzwave/quby/qb2.xml new file mode 100644 index 00000000..3213895d --- /dev/null +++ b/openzwave/quby/qb2.xml @@ -0,0 +1,15 @@ + + + http://www.openzwave.com/device-database/0130:0001:0001 + images/quby/qb2.png + https://products.z-wavealliance.org/products/683/ + Quby QB2 Energy Display + QEDII + Australia / New Zealand + QB2 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/683/xml + + + + diff --git a/openzwave/rcs/em52-zw.xml b/openzwave/rcs/em52-zw.xml new file mode 100644 index 00000000..0d176bce --- /dev/null +++ b/openzwave/rcs/em52-zw.xml @@ -0,0 +1,36 @@ + + + http://www.openzwave.com/device-database/0010:3532:454D + images/rcs/em52-zw.png + https://products.z-wavealliance.org/products/588/ + Overview + +The RCS Energy Meter Series networked power meters are sub-metering devices designed to provide timely and accurate consumption data. These meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring single-phase circuit installations. Input for 2 CT s can be used to monitor whole house usage (L1 + L2) or 2 single-phase sub-loads. + +Technical Specifications + +- Residential Single-phase Configuration – Model EM52 +- 2 Single-phase CT inputs for Whole House consumption +- Automatically adjusts for CT orientation +- Greatly reduces setup time and installation errors +- All-in-One design with flexible antenna for maximum RF range and ease of installation +- Accuracy: +/- 1% of reading +- Frequency: 50/60Hz +- Current Transformer Input: (0-0.333v) (0 – 3.3V) +- Selectable Current Transformer range (5A-150A) +- Built-in burden resistor +- Output Power : Isolated 12VDC 200mA +- RF Interface: Z-Wave +- LED indicators +- Agency approval: FCC, ETL + U.S. / Canada / Mexico + EM52 Z-Wave Energy Meter + http://www.rcstechnology.com/pages/products/z-wave-w-h-meter.html + EM52 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/588/xml + + + + + diff --git a/openzwave/rcs/pm12-zw.xml b/openzwave/rcs/pm12-zw.xml new file mode 100644 index 00000000..86e76793 --- /dev/null +++ b/openzwave/rcs/pm12-zw.xml @@ -0,0 +1,7 @@ + + + + + + + diff --git a/openzwave/rcs/therm0005.xml b/openzwave/rcs/therm0005.xml new file mode 100644 index 00000000..ab653e08 --- /dev/null +++ b/openzwave/rcs/therm0005.xml @@ -0,0 +1,23 @@ + + + + + + + + + + + true + + + + + + 0 + + + + + + diff --git a/openzwave/rcs/therm0007.xml b/openzwave/rcs/therm0007.xml new file mode 100644 index 00000000..515e6719 --- /dev/null +++ b/openzwave/rcs/therm0007.xml @@ -0,0 +1,43 @@ + + + + + + + + + + + true + + + + + + + + + + + + + + + + + + + + true + + + + + + + + 0 + true + + + diff --git a/openzwave/rcs/therm0009.xml b/openzwave/rcs/therm0009.xml new file mode 100644 index 00000000..0bdf5d71 --- /dev/null +++ b/openzwave/rcs/therm0009.xml @@ -0,0 +1,32 @@ + + + http://www.openzwave.com/device-database/0010:0009:0001 + images/rcs/therm0009.png + https://products.z-wavealliance.org/products/82/ + Z-Wave Thermostat.Separate Heat and Cool Setpoints + Up to 3 Stage Heat, 2 Stage Cool + Remote control of most functions via Zwave + Two part design or New 1 piece design + Backlit LCD Wall Display Unit + For standard gas/electric or heat pump HVAC systems + Replaces existing 4 or more wire thermostats without the need for additional wiring (TZ16/TZ40) + Optional Remote Temperature Sensor + Power: 24VAC supplied from HVAC system + Supports the ZWave thermostat device class + + http://www.rcstechnology.com/pages/products/thermo-z-wave.html + TZ45 Z-Wave Thermostat + U.S. / Canada / Mexico + http://www.rcstechnology.com/oldsite/products/stats/zwave.htm + TZ45 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/82/xml + + + + + + 0 + + + diff --git a/openzwave/remotec/bw8120eu.xml b/openzwave/remotec/bw8120eu.xml new file mode 100644 index 00000000..cbeb7e3e --- /dev/null +++ b/openzwave/remotec/bw8120eu.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/5254:8120:8201 + images/remotec/bw8120eu.png + https://products.z-wavealliance.org/products/801/ + CEPT (Europe) + Dual Mode Switch-Dimmer + BW8120EU + Dual Mode Switch-Dimmer + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/801/xml + + + diff --git a/openzwave/remotec/zfm-80.xml b/openzwave/remotec/zfm-80.xml new file mode 100644 index 00000000..6e3ba820 --- /dev/null +++ b/openzwave/remotec/zfm-80.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/5254:0002:8000 + images/remotec/zfm-80.png + https://products.z-wavealliance.org/products/660/ + ZFM-80/ZDW-80/ZRW-80 + U.S. / Canada / Mexico + http://www.remotec.com.hk/zaspx/support.aspx + ZFM-80US .ZDW-80US Z-Wave Dimmer & ZRW-80US Z-Wave Wall Switch + http://www.remotec.com.hk/zaspx/product_content.aspx?aboutno=37&subaboutno=37&main=t + ZFM-80, ZDW-80, ZRW-80 US Binary Switch + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/660/xml + + + + + + Set external switch type. + + + + + + + + Set timeout period. + + + Configure Node ID number for Z-Wave command source. + + + Set relay output status if timeout period has been reached. + + + + + + + + + + + diff --git a/openzwave/remotec/zrc-100eu.xml b/openzwave/remotec/zrc-100eu.xml new file mode 100644 index 00000000..4f862083 --- /dev/null +++ b/openzwave/remotec/zrc-100eu.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/5254:8380:0001 + images/remotec/zrc-100eu.png + https://products.z-wavealliance.org/products/1639/ + Remotec bw8380eu + CEPT (Europe) + ZRC-100EU / BW8380EU + ZRC-100EU + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1639/xml + + + diff --git a/openzwave/remotec/zrc-90.xml b/openzwave/remotec/zrc-90.xml new file mode 100644 index 00000000..0f9e4e9b --- /dev/null +++ b/openzwave/remotec/zrc-90.xml @@ -0,0 +1,26 @@ + + + http://www.openzwave.com/device-database/5254:8510:0001 + images/remotec/zrc-90.png + https://products.z-wavealliance.org/products/1584/ + Press “L+R” buttons simultaneously until LED light up to add the device into ZRC-90 Z-Wave network. + Click once on the “R” button to remove the device from ZRC-90 Z-Wave network. + BW8510EU + The ZRC-90 Scene Master is a Z-Wave Central Scene Controller. When one of the buttons on the ZRC-90 is pushed, your Z-Wave central controller will receive a signal which it can use to trigger unlimited control possibilities. With 8 buttons, each supporting a long-press capability, you can control 16 different actions in your central controller. The ZRC-90 is a great solution for triggering events more quickly than taking out your smart-phone and running a home control app. The Scene Master is ideal for kids, elderlies and guests who may not have full access to your smart home’s mobile application and hence may not have the rights to switch on various lighting, heating, air conditioning and other home appliance. With a convenient snap-in wall mount, the ZRC-90 can also be removed to keep it handy while you go about your home for the ultimate in simple convenience. + ZRC-90EU + Press and keep holding “R” button not less than 10 seconds. +Release “R” button then triple click on “R” button within 2 seconds. + Enter to the Listening mode (Wake up) by click once on “W” button. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1584/F-BW8510xx (ZRC-90xx) User Manual_V1.01_20151030.pdf + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1584/xml + + + + + + + + + diff --git a/openzwave/remotec/zts-110.xml b/openzwave/remotec/zts-110.xml new file mode 100644 index 00000000..9c24f948 --- /dev/null +++ b/openzwave/remotec/zts-110.xml @@ -0,0 +1,189 @@ + + + http://www.openzwave.com/device-database/5254:8031:0200 + images/remotec/zts-110.png + https://products.z-wavealliance.org/products/679/ + BW8031US + ZTS-110US Thermostat + U.S. / Canada / Mexico + http://www.remotec.com.hk/photos/software/Z-wave/ZTS-100_User_Manual_V10_20120615.pdf + The ZTS-100 Z-Thermostat is a comfort control master that allows to control your room temperature with programmable time schedule WAKE, AWAY, HOME and SLEEP event which can maximize energy conservation and comfort while minimizing the effort required to maintain the appropriate temperature in your home whether you are at home or away. + +Also, it can be utilized to control / check your room temperature by the smart phone or PC while you are at office, home anywhere or around the world which can go through the Z-Wave gateway control. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/679/xml + + + + + + 0 + + + + + + + Swing is the difference allowed from current temp to setpoint before the thermostat turns on. + EG: A swing of 2 and setpoint of 70 means the heat turns on at 68 and off at 72. + + + + + Differential is the difference needed from the swing before the 2nd stage kicks in. + EG: A swing of 2, differntial of 2, and setpoint of 70 means the heat turns on at 68 and off at 72. The second-stage heat would turn on at 67 and off at 68. + + + + How many hours before the filter change reminder is displayed. + + + How many hours the system has run since the filter counter was last reset. Read only. + + + Celsius or Fahrenheit. + + + + + + On thermostats that automatically control both heating and cooling systems, + a dead band is a temperature range in which neither system turns on. The dead + band prevents the thermostat from activating heat and cooling in rapid + succession. This conserves energy by providing a range of temperatures + requiring no energy consumption. + Dead band value: + 3(0x03)= 3 F / 1.5 C + 4(0x04)= 4 F / 2.0 C + 5(0x05)= 5 F / 2.5 C + 6(0x06)= 6 F / 3.0 C + + + + + Unit in C: + Range from 5 to [(37 ) - (dead band)] + Range from 50 (0x0032) to 355 (0x0163) + Example 28 ; input = 280 (0x0118) + + Unit in F: + Range from 41 to [(99 ) - (dead band)] + Range from 410 (0x019A) to 960 (0x03C0) + Example 82 ; input = 820 (0x0334) + Default = (99 ) - (dead band) + + + + + Unit in C: + Range from [(5 C) + (dead band)] to 37 C + Range from 65 (0x0041) to 370 (0x0172) + Example 20 C; input = 200 (0x00C8) + + Unit in F: + Range from [(41 F) + (dead band)] to 99 F + Range from 440 (0x01B8) to 990 (0x03DE) + Example 68 F; input = 680 (0x02A8) + Default = (41 F) + (dead band) + + + + Easy mode hides advanced features on the thermostat interface. + + + + + Use the 24 hour or 12 hour (am/pm) time format. + + + + + + Repeat basic set counter (Association Group A and B only) + Value(X): 0 (0x00), 3 (0x03) to 255 (0xFF) + 0 (0X00) = Disable, default + 3 (0x03) to 255 (0xFF) minutes + (Thermostat sends "Basic Set" command to its association node repeatedly in every X minutes) + + + + + Trigger AUTO report if room temperature is different from last + report. (It will report room temperature only) + *User can use this function to enhance batteries service life + 0 (0x00) = disable AUTO report if room temperature is different from last report. + AUTO report if room temperature is different from last report. + Delta change is >= + 1 (0x01) = 1 F (0.5 C) + 2 (0x02) = 2 F (1.0 C) + 3 (0x03) = 3 F (1.5 C) + 4 (0x04) = 4 F (2.0 C), (default) + 5 (0x05) = 5 F (2.5 C) + 6 (0x06) = 6 F (3.0 C) + 7 (0x07) = 7 F (3.5 C) + 8 (0x08) = 8 F (4.0 C) + + + + + AUTO report by time interval. (It will report room temperature only) + *User can use this function to enhance batteries service life. + 0 (0x00) = disable AUTO report function. (by time interval) + AUTO report timer: + 1 (0x01) = 0.5 hr + 2 (0x02) = 1.0 hr, (default) + 3 (0x03) = 1.5 hrs + 4 (0x04) = 2.0 hrs + 5 (0x05) = 2.5 hrs + 6 (0x06) = 3.0 hrs + 7 (0x07) = 3.5 hrs + 8 (0x08) = 4.0 hrs + 9 (0x09) = 4.5 hrs + 10 (0x0A) = 5.0 hrs + 11 (0x0B) = 5.5 hrs + 12 (0x0C) = 6.0 hrs + 13 (0x0D) = 6.5 hrs + 14 (0x0E) = 7.0 hrs + 15 (0x0F) = 7.5 hrs + 16 (0x10) = 8.0 hrs + + + + + This parameter is used to change the display temperature + to match with your previous thermostat, or to match another + thermostat already in your home + Formula: Display temperature = sensor reading value + offset value + 0 (0x00) = 0 F (default) + 1 (0x01) = 1 F (0.5 C) + 2 (0x02) = 2 F (1.0 C) + 3 (0x03) = 3 F (1.5 C) + 4 (0x04) = 4 F (2.0 C) + 5 (0x05) = 5 F (2.5 C) + 6 (0x06) = 6 F (3.0 C) + 7 (0x07) = 7 F (3.5 C) + 8 (0x08) = 8 F (4.0 C) + 9 (0x09) = 9 F (4.5 C) + 10 (0x0A) = 10 F (5.0 C) + -1 (0xFF) = -1 F (-0.5 C) + -2 (0xFE) = -2 F (-1.0 C) + -3 (0xFD) = -3 F (-1.5 C) + -4 (0xFC) = -4 F (-2.0 C) + -5 (0xFB) = -5 F (-2.5 C) + -6 (0xFA) = -6 F (-3.0 C) + -7 (0xF9) = -7 F (-3.5 C) + -8 (0xF8) = -8 F (-4.0 C) + -9 (0xF7) = -9 F (-4.5 C) + -10 (0xF6) = -10 F (-5.0 C) + + + + + + + + + + + + diff --git a/openzwave/remotec/zts-500.xml b/openzwave/remotec/zts-500.xml new file mode 100644 index 00000000..0911d9c6 --- /dev/null +++ b/openzwave/remotec/zts-500.xml @@ -0,0 +1,276 @@ + + + http://www.openzwave.com/device-database/5254:8170:0200 + images/remotec/zts-500.png + https://products.z-wavealliance.org/products/1767/ + Press and keep holding > or < for 3 seconds to navigate to the System Main (SYS) screen. +Press > to navigate to the Reset (RST) screen. +Press + or - to select Yes. +Press and keep holding > for 2 seconds to confirm your selection. +Press < to cancel and back to the previous screen. +Use the RESET procedure ONLY when the primary Controller is missing or inoperable. + + U.S. / Canada / Mexico + ZTS-500 is a user-friendly Z-Wave programmable smart thermostat. The ZTS-500 is compatible with any Z-Wave certified controller or gateway and is designed to fit perfectly over most original thermostat installation marks without the need for a mounting board. The invisible 4-button back-illuminated interface combines a simple and intuitive interactive experience with a modern fashionable look. The flip-over terminal-board makes installation a breeze, The ZTS-500US allows utilization even in environments where a C wire is not available. With automatic power source detection (24Vac or Battery Power), it decide to maximizing battery life or acting as a range extender in the Z-Wave network, and all your connections will be safe and secure behind AES128 encryption. The ZTS-500’s available multi-color faceplates allow for seamless integration into a variety of interior designs. + From the Standby screen, press > or < to navigate to the Z-Wave screen and the Z-Wave LED will continuously flash. +Tap + to include the ZTS-500 into the network. +- The “✔” symbol will be displayed on screen once the ZTS-500 is added into the network. +The Z-Wave disconnect icon will also be removed from the standby screen. + +- The “x” symbol will be displayed on screen if there is no action (time out) or unable to include the ZTS-500 into the network. + + ZTS-500 + Press and keep holding > or < for 3 seconds to navigate to the System Main (SYS) screen. +On the Z-Wave (Z-w) screen. +Tap + to exclude ZTS-500 from the network. +Press < to cancel and back to the previous screen. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1767/F-BW8170US (ZTS-500US) User_Manual_V1.01_Z-Wave validation_20160510.pdf + Z-WAVE SMART THERMOSTAT + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1767/xml + Update to include AU version, which is idential to the US version but with a different type + + https://products.z-wavealliance.org/products/1767/xml + ZTS-500 + Australia / New Zealand + + + + + + + false + 0 + + + + + + Celsius or Fahrenheit. + + + + + + Swing is the difference allowed from current temp to setpoint before the thermostat turns on. + EG: A swing of 2 and setpoint of 70 means the heat turns on at 68 and off at 72. + + + + + Differential is the difference needed from the swing before the 2nd stage kicks in. + EG: A swing of 2, differntial of 2, and setpoint of 70 means the heat turns on at 68 and off at 72. The second-stage heat would turn on at 67 and off at 68. + + + + + On thermostats that automatically control both heating and cooling systems, + a dead band is a temperature range in which neither system turns on. The dead + band prevents the thermostat from activating heat and cooling in rapid + succession. This conserves energy by providing a range of temperatures + requiring no energy consumption. + Dead band value: + 3(0x03)= 3 F / 1.5 C + 4(0x04)= 4 F / 2.0 C (default) + 5(0x05)= 5 F / 2.5 C + 6(0x06)= 6 F / 3.0 C + + + + + + + + + Unit in C: + Range from 5 to [(37 ) - (dead band)] + Range from 50 (0x0032) to 355 (0x0163) + Example 28 ; input = 280 (0x0118) + + Unit in F: + Range from 41 to [(99 ) - (dead band)] + Range from 410 (0x019A) to 960 (0x03C0) + Example 82 ; input = 820 (0x0334) + Default = (99 ) - (dead band) + + + + + Unit in C: + Range from [(5 C) + (dead band)] to 37 C + Range from 65 (0x0041) to 370 (0x0172) + Example 20 C; input = 200 (0x00C8) + + Unit in F: + Range from [(41 F) + (dead band)] to 99 F + Range from 440 (0x01B8) to 990 (0x03DE) + Example 68 F; input = 680 (0x02A8) + Default = (41 F) + (dead band) + + + + + 0 (0x00) (default) + + + + How many hours before the filter change reminder is displayed. + + + How many hours the system has run since the filter counter was last reset. Read only. + + + + This parameter is used to change the display temperature + to match with your previous thermostat, or to match another + thermostat already in your home + Formula: Display temperature = sensor reading value + offset value + 0 (0x00) = 0 F (default) + 1 (0x01) = 1 F (0.5 C) + 2 (0x02) = 2 F (1.0 C) + 3 (0x03) = 3 F (1.5 C) + 4 (0x04) = 4 F (2.0 C) + 5 (0x05) = 5 F (2.5 C) + 6 (0x06) = 6 F (3.0 C) + 7 (0x07) = 7 F (3.5 C) + 8 (0x08) = 8 F (4.0 C) + 9 (0x09) = 9 F (4.5 C) + 10 (0x0A) = 10 F (5.0 C) + -1 (0xFF) = -1 F (-0.5 C) + -2 (0xFE) = -2 F (-1.0 C) + -3 (0xFD) = -3 F (-1.5 C) + -4 (0xFC) = -4 F (-2.0 C) + -5 (0xFB) = -5 F (-2.5 C) + -6 (0xFA) = -6 F (-3.0 C) + -7 (0xF9) = -7 F (-3.5 C) + -8 (0xF8) = -8 F (-4.0 C) + -9 (0xF7) = -9 F (-4.5 C) + -10 (0xF6) = -10 F (-5.0 C) + + + + + + + + + + + + + + + + + + + + + + + + + + 1 (0x01) = Level-1 (dark) + 2 (0x02) = Level-2 (middle) , default + 3 (0x03) = Level-3 (bright) + + + + + 3 (0x03) to 60 (0x3C) seconds, + 255 (0xFF) = Always On + Step size = 1s, + Batt = 5s, default + 24Vac = 60s, default + + + + + Repeat basic set counter (Association Group A and B only) + Value(X): 0 (0x00), 3 (0x03) to 255 (0xFF) + 0 (0X00) = Disable, default + 3 (0x03) to 255 (0xFF) minutes + (Thermostat sends "Basic Set" command to its association node repeatedly in every X minutes) + + + + + Trigger AUTO report if room temperature is different from last + report. (It will report room temperature only) + *User can use this function to enhance batteries service life + 0 (0x00) = disable AUTO report if room temperature is different from last report. + AUTO report if room temperature is different from last report. + Delta change is >= + 1 (0x01) = 1 F (0.5 C), (default if powered by 24Vac) + 2 (0x02) = 2 F (1.0 C), (default if powered by battery) + 3 (0x03) = 3 F (1.5 C) + 4 (0x04) = 4 F (2.0 C) + 5 (0x05) = 5 F (2.5 C) + 6 (0x06) = 6 F (3.0 C) + 7 (0x07) = 7 F (3.5 C) + 8 (0x08) = 8 F (4.0 C) + + + + + + + + + + + + + AUTO report by time interval. (It will report room temperature only) + *User can use this function to enhance batteries service life. + 0 (0x00) = disable AUTO report function. (by time interval), (default) + AUTO report timer: + 1 (0x01) = 0.5 hr + 2 (0x02) = 1.0 hr + 3 (0x03) = 1.5 hrs + 4 (0x04) = 2.0 hrs + 5 (0x05) = 2.5 hrs + 6 (0x06) = 3.0 hrs + 7 (0x07) = 3.5 hrs + 8 (0x08) = 4.0 hrs + 9 (0x09) = 4.5 hrs + 10 (0x0A) = 5.0 hrs + 11 (0x0B) = 5.5 hrs + 12 (0x0C) = 6.0 hrs + 13 (0x0D) = 6.5 hrs + 14 (0x0E) = 7.0 hrs + 15 (0x0F) = 7.5 hrs + 16 (0x10) = 8.0 hrs + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/remotec/zurc.xml b/openzwave/remotec/zurc.xml new file mode 100644 index 00000000..bdea9117 --- /dev/null +++ b/openzwave/remotec/zurc.xml @@ -0,0 +1,43 @@ + + + http://www.openzwave.com/device-database/5254:531F:0000 + images/remotec/zurc.png + https://products.z-wavealliance.org/products/174/ + Z-Wave enabled universal remote control + Z-URC500US + The Z-URC™ product line is Remotec’s answer to the increasing demand for RF solutions. By combining our traditional high-quality IR universal remote control expertise with Z-Wave® (RF) technology, we have succeeded in producing home automation remote controls that truly fulfill the role of “One Home, One Remote.” Z-URC’s dual IR/RF capabilities allow you to control virtually any electronic device in your household. Whether it is for simple home electronics, outdoor lighting or that high end home entertainment system, the Z-URC family of solutions can solve your needs. With the Z-URC, you can enjoy the culmination of 20+ years of universal remote control experience. + http://www.remotec.com.hk/zaspx/product_content.aspx?aboutno=9&subaboutno=22&main=f + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/174/xml + + + + + + + + + + + + + + + + + + + + + + + + + + + false + + + diff --git a/openzwave/remotec/zxt-120.xml b/openzwave/remotec/zxt-120.xml new file mode 100644 index 00000000..881c40a1 --- /dev/null +++ b/openzwave/remotec/zxt-120.xml @@ -0,0 +1,146 @@ + + + http://www.openzwave.com/device-database/5254:8377:0101 + images/remotec/zxt-120.png + https://products.z-wavealliance.org/products/715/ + BW8377EU + Remotec BW8377IL + Remotec BW8377IL + http://www.remotec.com.hk/zaspx/product_content.aspx?aboutno=36&subaboutno=45&main=f + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/715/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1551/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1552/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1830/xml + + https://products.z-wavealliance.org/products/1551/ + BW8377AU + Australia / New Zealand + https://products.z-wavealliance.org/products/1552/ + U.S. / Canada / Mexico + BW8377US + https://products.z-wavealliance.org/products/1830/ + BW8377IL + Israel + + + + + + false + 0 + + + + + + + + + + + + + + + + + + + + + + + + true + + + + + + In case none of the code on the code list works for the targeted air conditioner, user can use IR code learning function. + See manual at section "IR Code Learning" for a description of the procedure. Value 0-22 + + + + + + + + + + + + + + + + + + + + + + + + + + Note: The status value 0x01 and 0x04 will be reset to 0 when the ZXT-120 receive a get command to this parameter. + Idle - this IR channel is idle (default). + OK - the latest learning process successful and completed. + Learning - the ZXT- 120 is busy processing previous learning request. + Failed - the latest learning request failed. + + + + + + + Look up the code list of ZXT-120 according to your AC brand. + + + + + + + + + To avoid the IR interference by disabling the surrounding IR emitter if 2 air-conditioners in a room are used. + Extend the battery life by disabling the Surround IR Emitters + + + + + + + + + + + + Bit mask = 1, learn location has learn data. + Otherwise, Bit mask 0 See figure Learn location + + + + + This parameter is used to compensate the temperature error at temperature sensor. + Formula: Display temperature = sensor reading value + offset value + (unit = degree C) + 0x00 = 0C (Default) + + + + + + + + + + + + + + + diff --git a/openzwave/remotec/zxt-310.xml b/openzwave/remotec/zxt-310.xml new file mode 100644 index 00000000..de624420 --- /dev/null +++ b/openzwave/remotec/zxt-310.xml @@ -0,0 +1,77 @@ + + + http://www.openzwave.com/device-database/5254:8371:0100 + images/remotec/zxt-310.png + https://products.z-wavealliance.org/products/1540/ + Z-Wave to IR extender for Audio/Video devices with built-in and cloud-based IR library. + Remotec ZXT-310US + U.S. / Canada / Mexico + BW8371US + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1540/xml + + + + + + IR code number for built-in code library. Refer "Code list" for details. + + + + + * 1 (0x01) = EP1 + * 1 (0x02) = EP2 + * 1 (0x03) = EP3 + * 1 (0x04) = EP4 + * 1 (0x05) = EP5 + * 1 (0x06) = EP6 + + + + + IR output port routing. + Please make sure that the "End point selection control" has completed (if necessary) before process the following setup. + + + + + Please make sure that the "End point selection control" has completed (if necessary) before process the following setup. + + Set IR output power level by entering: + * 0 (0x00) Normal power mode; + * 255 (0xFF) High power mode; + (default is in high power mode). + + + + + Please make sure that the "End point selection control" has completed (if necessary) before process the following setup. + + Place the ZXT-310 and your original remote on a flat surface, aimed at each other and 1-3 cm apart from the "L" learning mark. + Press and keep holding the key on your original equipment remote which you want to learn for a few seconds. + + Value is the Simple AV command number or key going to be learned. + Any incoming operation may probably to wait up to 15s to release until the internal process of parameter has finished. + + (Z-Wave Cmd#, e.g. if POWER key is going to be learnt, input the value: 39 (0x27)) + + + + + * 0 (0x00): IR channel idle (default) + * 1 (0x01): OK + * 2 (0x02): Learning + * 3 (0x03): Command Full + * 4 (0x04): Learning Fail + + + + + Please make sure that the "End point selection control" has completed (if necessary) before process the following setup. + + * 0 (0x00): Continuous IR transmission mode (default); + * 255 (0xFF): Single shot IR transmission mode; + + + + diff --git a/openzwave/remotec/zxt-600.xml b/openzwave/remotec/zxt-600.xml new file mode 100644 index 00000000..b57efd5d --- /dev/null +++ b/openzwave/remotec/zxt-600.xml @@ -0,0 +1,187 @@ + + + http://www.openzwave.com/device-database/5254:8490:0100 + images/remotec/zxt-600.png + https://products.z-wavealliance.org/products/2445/ + 1, Refer to your primary controller to enter into the Inclusion Mode or Exclusion Mode +2, When it is prompted to enter it, please triple click the “PROG” button within 1 second. +3, Green Indicator flashes TWICE then stay off + AC MASTER + 1, Refer to your primary controller to enter into the Inclusion Mode or Exclusion Mode +2, When it is prompted to enter it, please triple click the “PROG” button within 1 second. +3, Green Indicator flashes TWICE then stay off + ZXT-600 AC Master is a Z-Wave plus certified IR Bridge for split air conditioner control by receiving Z-Wave command and translating to Infrared command and flawlessly work with any Z-Wave compliant gateway. +With its over 250 brands built-in code library and ever-green up to date cloud IR database supporting advanced code learning search, ZXT-600 can easily set up and smart control most of AC brands and models actively worldwide by Z-Wave gateway. +The battery powered device will allow you to mount it anywhere you want such as wall, ceiling or put it on table and never compromise on the form factor. By supporting OTA function, gateway can enable ZXT-600 to update firmware if newest available. + + Press and Hold “PROG” button for 3 seconds on AC Master, the Green Indicator will light up. DO NOT Release the “PROG” Button until Green Indicator flashes TWICE. +Remark : Please use this procedure only when the network primary controller is missing or otherwise inoperable. + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2553/BW8490_Installation_Guide_201700807.pdf + ZXT-600US + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2445/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2553/xml + + https://products.z-wavealliance.org/products/2553/ + Press the "PROG" button to wakeup the unit + ZXT-600EU + CEPT (Europe) + + + + + + + + false + 0 + + + + + + + + + + + + + + + + + + + + + + + + true + + + + + + In case none of the code on the code list works for the targeted air conditioner, user can use IR code learning function. + See manual at section "IR Code Learning" for a description of the procedure. Value 0-22 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + Note: The status value 0x01 and 0x04 will be reset to 0 when the ZXT-120 receive a get command to this parameter. + Idle - this IR channel is idle (default). + OK - the latest learning process successful and completed. + Learning - the ZXT- 120 is busy processing previous learning request. + Failed - the latest learning request failed. + + + + + + + Refer to Code Finder Web page. + + + + Set Auto Report Condition Trigger By Room Temperature change. + Disable AUTO report function (Default) for saving battery life. + Auto report if room temperature is different from last report. + + + + + + + + + + + + + + To avoid the IR interference by disabling the surrounding IR emitter if 2 air-conditioners in a room are used. + Extend the battery life by disabling the Surround IR Emitters + + + + + + + + + + + + Set Auto Report Condition Trigger By Time interval + + + + + + + + + + + + + Temperature offset value. + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/ring/PIR-SS.xml b/openzwave/ring/PIR-SS.xml new file mode 100644 index 00000000..504bfa23 --- /dev/null +++ b/openzwave/ring/PIR-SS.xml @@ -0,0 +1,70 @@ + + + Ring PIR-SS Motion Sensor + Ring Motion sensor is a Z-Wave passive infrared (PIR) motion detector which will be used as a primary intrusion detection unit in the system. + http://www.openzwave.com/device-database/0346:0201:0301 + images/ring/PIR-SS.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2664/Ring%20Motion%20Sensor%20-%20Manual.pdf + Removing the top cover will put the sensor in tamper mode and will keep the sensor awake + Exclusion Instructions: +1. Initiate remove sensor flow in the Ring Alarm mobile application – Select the settings icon from device details page and choose “Remove Device” +2. Open motion sensor’s cover +3. Remove and replace battery quickly + + Inclusion instructions: +1. Install battery, or remove battery tab. Replace cover +2. Place Zwave device controller into inclusion mode. +3. Remove cover. Device LED should go on +4. Press down the tamper cover microswitch for one second then release. +5. Replace cover. + + Factory Default Instructions +1. Using a pointed end of a paperclip, press and hold the reset button via the reset pin hole found at the back of the sensor +2. Blue LED will start to blink rapidly +3. Wait for the blue LED to stop blinking + +Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + https://products.z-wavealliance.org/products/2664/ + PIR-SS + U.S. / Canada / Mexico + + Initial Metadata Creation + + + + + + Interval which unsolicted reports are sent. + + + + + Time which sensor will hold onto a motion detected or cleared event. + + + + + Pet Immunity Setting + + + + + + + + Activate walk test for 15 minutes + + + + + + + + + + + + + + diff --git a/openzwave/schlage/BE468.xml b/openzwave/schlage/BE468.xml new file mode 100644 index 00000000..cc9c364f --- /dev/null +++ b/openzwave/schlage/BE468.xml @@ -0,0 +1,72 @@ + + + + + + Enable or disable the beeper. + + + + + + + + Prevents all user codes from unlocking the deadbolt. + Enable for extra security while you are away for + an extended period of time. + + + + + + + When enabled: Press the Outside Schlage Button to lock the + deadbolt. (Default setting). + When disabled: Press the Outside Schlage Button and then enter + a user code to lock the deadbolt. + + + + + + + + + Each failed electronic attempt increments this count by one. + + + + + When enabled, the lock will automatically relock 30 seconds + after unlocking. (Disabled by default.) + + + + + + + User Code PIN length, a value between 4 and 8. + IMPORTANT: All user codes must be the same length. + + + + + A subset of Electronic transition count, the number of transitions + with high preload. + + + + The version of the bootloader + + + + + + + + + + diff --git a/openzwave/schlage/BE468ZP.xml b/openzwave/schlage/BE468ZP.xml new file mode 100644 index 00000000..507b77f3 --- /dev/null +++ b/openzwave/schlage/BE468ZP.xml @@ -0,0 +1,134 @@ + + + http://www.openzwave.com/device-database/003B:0468:0001 + images/schlage/BE468ZP.png + https://products.z-wavealliance.org/products/3028/ + The Schlage Connect™ Smart Deadbolt combines advanced features and compatibility with your home automation or security system, allowing you to control your lock from anywhere and freeing you from the hassles of lost keys, getting locked out, or hiding a spare for friends and family. + +The lock comes preprogrammed with two access codes and can hold up to 30 unique codes for family members and trusted friends. The fingerprint-resistant touchscreen helps access codes stay private, minimizing tell-tale wear that can tip off possible intruders. + +The Schlage Connect Smart Deadbolt is battery-powered with a low battery warning that gives you weeks of advanced notice before it runs out. With guaranteed fit on standard doors, it’s easy for homeowners to install in minutes with just a screwdriver. The touchscreen continues to work in the event of a power outage, so you don’t have to worry about getting locked out – plus, a back-up key is included with the lock for peace of mind. + +The Schlage Connect Smart Deadbolt incorporates Z-Wave Plus S2 technology, an enhanced security protocol that features an additional layer of AES encryption of wireless signals. The Z-Wave technology allows you to integrate your exterior door locks with other Z-Wave smart home devices, such as cameras, motion detectors, lights and thermostats, bringing the safety, simplicity and style of Schlage to your smart home. + + One-button Remove lock from Z-Wave Network (Exclusion) + +1. Place your home automation system or panel into the “Remove” or Exclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). +2. Remove the battery cover of the deadbolt. +3. Press then release the button on the PCB. +4. An LED will flash amber indicating the “Remove” or Exclusion process is in progress. +5. When a green LED flashes 3 times, the “Remove” or Exclusion process is completed successfully. +6. If a red LED turns ON, try repeating steps 1-3 + +Interactive Instruction for Remove https://instructions.allegion.com/instr/86/2581 + U.S. / Canada / Mexico + Schlage Connect Smart Deadbolt + BE468ZP + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3028/Connect_QSG_Add_Remove_FDR_Association.pdf + Steps for One-button Factory Default Reset + +1. Remove the battery cover of the deadbolt +2. Press and hold the button on the PCB for 7 (seven) seconds. +While holding the button pressed, after 1 sec LED will be lit for 2 sec. and turn OFF; continue to press and hold the button until the LED will be lit again and release the button. +3. The LED will blink red three times and the green check on the touchscreen will blink if the Factory Default Reset is successful. +4. To check that the lock was reset, press the Schlage Button and enter one of the Default User Codes. If the reset was successful, the Default User Codes will unlock the deadbolt. +NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + One-button Add lock to Z-Wave Network (Inclusion) + +1. Place your home automation system or panel into the “Add” or Inclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). +2. Remove the battery cover of the deadbolt. +3. Press then release the button on the PCB. +4. An LED will flash amber indicating the “Add” or Inclusion process is in progress. +• If the Security Scheme is Security 2 (S2), verify the DSK of the lock at the Z-Wave Controller. The PIN Code portion of the Z-Wave DSK will be needed. +5. When a green LED turns ON, the “Add” or Inclusion has completed successfully. +6. If a red LED turns ON, try repeating steps 1-3 + +Interactive Instruction for Add +https://instructions.allegion.com/instr/86/2543 + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3028/xml + + + + + + Enable or disable the keypad beeper. + + + + + + + Enable or disable vacation mode. + Disables all user codes, preventing all codes from unlocking the deadbolt. + Enable for extra security while you are away for an extended period of time. + + + + + + + Enable or disable Lock and Leave Mode. + When enabled: Press the Schlage button on the keypad to lock the deadbolt (Default setting). + When disabled: Press the Schlage button on the keypad and then enter a user code to lock the deadbolt. + + + + + + + Indicates the number of transitions from locked to unlocked or unlocked to locked state via electronic activation. + + + + + Indicates the number of transitions from locked to unlocked or unlocked to locked state via mechanical activation. + + + + + Indicates the number of failed electronic activation attempts for this lock. + + + + + When enabled, the lock will automatically relock 30 seconds after unlocking. (Disabled by default.) + + + + + + + Choose user code length between 4 and 8 digits. + IMPORTANT: All user codes must be the same length. + + + + + Indicates the number of transitions from locked to unlocked or unlocked to locked state via electronic activation that indicated a high preload on the deadbolt. + This is a subset of Electronic transition count. + High preload occurs when the bolt is obstructed and the motor needs to use more power to throw the bolt. + Adjust door and strike plate to ensure the bolt can move freely. This will save battery power. + + + + The version of the bootloader in the lock. + + + + + + + + + + + + + + diff --git a/openzwave/schlage/BE469.xml b/openzwave/schlage/BE469.xml new file mode 100644 index 00000000..2fb9763b --- /dev/null +++ b/openzwave/schlage/BE469.xml @@ -0,0 +1,160 @@ + + + http://www.openzwave.com/device-database/003B:5044:6341 + images/schlage/BE469.png + https://products.z-wavealliance.org/products/748/ + BE469 + At Schlage, we know security. After all, we’ve been innovating locks for more than 90 years. Now, with the Touch screen Deadbolt, we’ve created a door lock that combines all of our best security features into one keyless door lock, redefining what it means to be secure. Our innovative touch screen feature provides the convenience of going keyless. No more keys to lose, hide, carry or forget. The fingerprint-resistant touch screen ensures numbers won’t be detectable to intruders after repeated use, safeguarding your home even more. Schrage’s Touch screen Deadbolt with Alarm combines our best security features into one door lock: Grade 1 certification, an Anti-pick shield, Built-in Alarm technology. The Touch screen Deadbolt is also enabled to work with Nexia Home Intelligence, a home automation system that allows you to control locks, thermostats, lights, cameras and more from wherever you and the Internet happen to be. + Schlage Touchscreen Deadbolt + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/748/xml + Fix TriggerRefreshValue index for Alarm Message + + + + + + Enable or disable the beeper. + + + + + + + Prevents all user codes from unlocking the deadbolt. + Enable for extra security while you are away for + an extended period of time. + + + + + + + When enabled: Press the Outside Schlage Button to lock the + deadbolt. (Default setting). + When disabled: Press the Outside Schlage Button and then enter + a user code to lock the deadbolt. + + + + + + + The alarm is turned off by default. After installation, + you will need to turn on your alarm. + + Activity + Alarms when the door opens or closes. + Perfect for monitoring doors while you re at home. + After the alarm is triggered, there is a built-in 3-second + delay for it to reset. + Sounds two short beeps. + + Tamper + Alarms when the lock is disturbed, while locked. + Senses subtle activity at the lock. + Sounds 15 second Alarm (90 dB) + + Forced Entry + Alarms when significant force pushes against the + door, while locked. Perfect for nighttime or + when you re away from home. + Least sensitive mode + Sounds three-minute shrill, steady alarm (90 dB) + + + + + + + + + Each alarm mode is preset to a sensitivity level of three. + If your alarm is sounding too frequently, or not frequently enough, + try changing this setting. + If you change the alarm mode, the sensitivity will revert + back to the default setting. + + + + + + + + + + Each alarm mode is preset to a sensitivity level of three. + If your alarm is sounding too frequently, or not frequently enough, + try changing this setting. + If you change the alarm mode, the sensitivity will revert + back to the default setting. + + + + + + + + + + Each alarm mode is preset to a sensitivity level of three. + If your alarm is sounding too frequently, or not frequently enough, + try changing this setting. + If you change the alarm mode, the sensitivity will revert + back to the default setting. + + + + + + + + + + Enables/Disables local alarm on/off, mode change, sensitivity changes + + + + + + + + + Each failed electronic attempt increments this count by one. + + + + + When enabled, the lock will automatically relock 30 seconds + after unlocking. (Disabled by default.) + + + + + + + User Code PIN length, a value between 4 and 8. + IMPORTANT: All user codes must be the same length. + + + + + A subset of Electronic transition count, the number of transitions + with high preload. + + + + The version of the bootloader + + + + + + + + + diff --git a/openzwave/schlage/BE469ZP.xml b/openzwave/schlage/BE469ZP.xml new file mode 100644 index 00000000..617988ba --- /dev/null +++ b/openzwave/schlage/BE469ZP.xml @@ -0,0 +1,203 @@ + + + http://www.openzwave.com/device-database/003B:0469:0001 + images/schlage/BE469ZP.png + https://products.z-wavealliance.org/products/3130/ + One-button Remove lock from Z-Wave Network (Exclusion) + +1. Place your home automation system or panel into the “Remove” or Exclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). +2. Remove the battery cover of the deadbolt. +3. Press then release the button on the PCB. +4. An LED will flash amber indicating the “Remove” or Exclusion process is in progress. +5. When a green LED flashes 3 times, the “Remove” or Exclusion process is completed successfully. +6. If a red LED turns ON, try repeating steps 1-3 + +Interactive Instruction for Remove https://instructions.allegion.com/instr/86/2581 + BE469ZP + U.S. / Canada / Mexico + The Schlage Connect™ Smart Deadbolt combines advanced features and compatibility with your home automation or security system, allowing you to control your lock from anywhere and freeing you from the hassles of lost keys, getting locked out, or hiding a spare for friends and family. + +The lock comes preprogrammed with two access codes and can hold up to 30 unique codes for family members and trusted friends. The fingerprint-resistant touchscreen helps access codes stay private, minimizing tell-tale wear that can tip off possible intruders. + +The Schlage Connect Smart Deadbolt is battery-powered with a low battery warning that gives you weeks of advanced notice before it runs out. With guaranteed fit on standard doors, it’s easy for homeowners to install in minutes with just a screwdriver. The touchscreen continues to work in the event of a power outage, so you don’t have to worry about getting locked out – plus, a back-up key is included with the lock for peace of mind. + +The Schlage Connect Smart Deadbolt incorporates Z-Wave Plus S2 technology, an enhanced security protocol that features an additional layer of AES encryption of wireless signals. The Z-Wave technology allows you to integrate your exterior door locks with other Z-Wave smart home devices, such as cameras, motion detectors, lights and thermostats, bringing the safety, simplicity and style of Schlage to your smart home. + + Schlage Connect Smart Deadbolt + One-button Add lock to Z-Wave Network (Inclusion) + +1. Place your home automation system or panel into the “Add” or Inclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). +2. Remove the battery cover of the deadbolt. +3. Press then release the button on the PCB. +4. An LED will flash amber indicating the “Add” or Inclusion process is in progress. +• If the Security Scheme is Security 2 (S2), verify the DSK of the lock at the Z-Wave Controller. The PIN Code portion of the Z-Wave DSK will be needed. +5. When a green LED turns ON, the “Add” or Inclusion has completed successfully. +6. If a red LED turns ON, try repeating steps 1-3 + +Interactive Instruction for Add +https://instructions.allegion.com/instr/86/2543 + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3130/Connect_QSG_Add_Remove_FDR_Association.pdf + Steps for One-button Factory Default Reset + +1. Remove the battery cover of the deadbolt +2. Press and hold the button on the PCB for 7 (seven) seconds. +While holding the button pressed, after 1 sec LED will be lit for 2 sec. and turn OFF; continue to press and hold the button until the LED will be lit again and release the button. +3. The LED will blink red three times and the green check on the touchscreen will blink if the Factory Default Reset is successful. +4. To check that the lock was reset, press the Schlage Button and enter one of the Default User Codes. If the reset was successful, the Default User Codes will unlock the deadbolt. +NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3130/xml + Update TriggerRefreshValue index. + + + + + + Enable or disable the keypad beeper. + + + + + + + Enable or disable vacation mode. + Disables all user codes, preventing all codes from unlocking the deadbolt. + Enable for extra security while you are away for an extended period of time. + + + + + + + Enable or disable Lock and Leave Mode. + When enabled: Press the Schlage button on the keypad to lock the deadbolt (Default setting). + When disabled: Press the Schlage button on the keypad and then enter a user code to lock the deadbolt. + + + + + + + By default the alarm is turned off by default. After intalling, you can turn the alarm on. + + Alert + Alarms when the door opens or closes. + Perfect for monitoring the door while you are home. + After the alarm is triggered, there is a built-in 3-second delay for it to reset. + sounds two short beeps. + + Tamper + Alarms when the lock is disturbed while locked. + Senses subtle activity at the lock. + Sounds 15 second alarm (90 dB). + + Forced Entry + Alarms when significant force pushes against the door while locked. + Perfect for nighttime or when you are away from home. + Least sensitive mode. Sounds 3-minute shrill, steady alarm (90dB). + + + + + + + + + Each alarm mode is preset to a sensitivity level of 3. + If your alarm is sounding too frequently, or not frequently enough, try changing this setting. + If you change the alarm mode, the sensitivity will revert back to the default setting. + + + + + + + + + + Each alarm mode is preset to a sensitivity level of 3. + If your alarm is sounding too frequently, or not frequently enough, try changing this setting. + If you change the alarm mode, the sensitivity will revert back to the default setting. + + + + + + + + + + Each alarm mode is preset to a sensitivity level of 3. + If your alarm is sounding too frequently, or not frequently enough, try changing this setting. + If you change the alarm mode, the sensitivity will revert back to the default setting. + + + + + + + + + + This configuration setting controls the ability to ENABLE or DISABLE local control of the built-in alarm function. + + + + + + + Indicates the number of transitions from locked to unlocked or unlocked to locked state via electronic activation. + + + + + Indicates the number of transitions from locked to unlocked or unlocked to locked state via mechanical activation. + + + + + Indicates the number of failed electronic activation attempts for this lock. + + + + + When enabled, the lock will automatically relock 30 seconds after unlocking. (Disabled by default.) + + + + + + + Choose user code length between 4 and 8 digits. + IMPORTANT: All user codes must be the same length. + + + + + Indicates the number of transitions from locked to unlocked or unlocked to locked state via electronic activation that indicated a high preload on the deadbolt. + This is a subset of Electronic transition count. + High preload occurs when the bolt is obstructed and the motor needs to use more power to throw the bolt. + Adjust door and strike plate to ensure the bolt can move freely. This will save battery power. + + + + The version of the bootloader in the lock. + + + + + + + + + + + + + + diff --git a/openzwave/schlage/fe599.xml b/openzwave/schlage/fe599.xml new file mode 100644 index 00000000..69ff406d --- /dev/null +++ b/openzwave/schlage/fe599.xml @@ -0,0 +1,17 @@ + + + http://www.openzwave.com/device-database/003B:504C:634B + images/schlage/fe599.png + https://products.z-wavealliance.org/products/311/ + U.S. / Canada / Mexico + cKPD FE599 z-wave Lock. Z-Wave enabled lock. We make it simple to get started with remote home security with the Schlage Home Security Kit. Everything you need to make sure your home and family are safe and secure when you’re not there is available in one box . Getting notified any time your loved ones come home or leave the house. Assigning codes to let in chosen guests. Turning on a light at night in an empty house – making it look full of life. Nexia security features come together in a system you can manage and monitor any time, whether from your office computer or on the go from your tablet or smart phone. + http://link.schlage.com/Products/Pages/DeadboltStarterKit.aspx + http://link.schlage.com/Products/Pages/DeadboltStarterKit.aspx + cKPD FE599 + cKPD FE599 Z-Wave Lock + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/311/xml + + + + diff --git a/openzwave/schlagelink/41.xml b/openzwave/schlagelink/41.xml new file mode 100644 index 00000000..04ffa780 --- /dev/null +++ b/openzwave/schlagelink/41.xml @@ -0,0 +1,15 @@ + + + http://www.openzwave.com/device-database/0097:5501:6941 + images/schlagelink/41.png + https://products.z-wavealliance.org/products/729/ + Product number 41, A plugin module for a power socket which can switch on/off + Wintop iPlug, Brazil + Brazil + 41 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/729/xml + + + + diff --git a/openzwave/schlagelink/itemp.xml b/openzwave/schlagelink/itemp.xml new file mode 100644 index 00000000..3137e179 --- /dev/null +++ b/openzwave/schlagelink/itemp.xml @@ -0,0 +1,31 @@ + + + + + + + + Attention: This will delete all your configuration, but the device will remain in the network. Handle with care. + + + + + + Configure what the external contact sends when trigger + + + + + + Defines if the sensor is in normal wakeup-mode or always on. This function shall be used only for testing since it draining the battery very fast. + + + + + + Offset to the temperature. This parameter can be used to calibrate the temperature sensor function if needed. Note. As factory default the temperature sensor function is calibrated. 0 = 0K (default), not 0 = Temperature Offset in K + + + + + diff --git a/openzwave/schlagelink/minikeypad.xml b/openzwave/schlagelink/minikeypad.xml new file mode 100644 index 00000000..299b7345 --- /dev/null +++ b/openzwave/schlagelink/minikeypad.xml @@ -0,0 +1,40 @@ + + + + + + Set all configuration values to default values (factory settings) if set to 0xff. + + + To configure the time the beep is automatically turned off in seconds. 0 means disabled. 255 is endless + + + To configure the timeout to wait for a WAKEUP_NO_MORE_INFORMATION before the error beep is automatically sound. The error beeps are fixed 8 beeps shortly after each other. 0 means disabled + + + To configure the number of beeps per second. Every beep is fixed about 10ms. + + + To configure the operating mode. If any mode other then 3, that value will be reported after a get but will be handled in SW as mode 1. + + + + + + + + false + + + + + true + + + + + + + + + diff --git a/openzwave/sensative/strips.xml b/openzwave/sensative/strips.xml new file mode 100644 index 00000000..808f6ecc --- /dev/null +++ b/openzwave/sensative/strips.xml @@ -0,0 +1,97 @@ + + + http://www.openzwave.com/device-database/019A:0003:0003 + images/sensative/strips.png + https://products.z-wavealliance.org/products/3388/ + Please use this procedure only when your Z-Wave controller is missing or otherwise inoperable: + +1. Place the round magnet at the rounded edge of Strips. + +2. When the LED blinks, move the magnet away. Repeat 3 times in total within 10 seconds. + +3. On the 3rd repetition, leave the magnet at the rounded edge for 10s. + +4. A long LED signal indicates success. + Wake up Strips manually for Z-Wave communication: + +1. Place the round magnet at the rounded edge of Strips. + +2. When the LED blinks, move the magnet away. + +3. Repeat 3 times in total within 10 seconds. + + Strips is delivered in "auto-add" mode. +Follow the process below to add Strips in a Z-Wave network. + +1. Start the add mode on the Z-Wave controller. +See the controller’s manual. + +2. Remove both magnets from Strips. Strips blinks twice to confirm the command and successful addition. + +3. A long LED blink indicates that the add process was successful + +4. The Z-Wave controller application should now allow you to monitor your Strips sensor status. + +5. Move the squared magnet as shown in the picture . Check that the Z-Wave system indicates the status correctly. + +6. If the Z-Wave system does not respond, it may be needed to change Strips’ notification type. + +Manual add: +1. Set the controller to add mode (See your controller’s manual). + +2. Place the round magnet at the rounded edge of Strips. +When the LED blinks, move the magnet away. Repeat 3 times in total within 10 seconds. + +3. A long LED blink indicates that the add process was successful. + + 11 01 015 + 1. Set the controller in remove mode (See your controller’s manual). + +2. Place the round magnet at the rounded edge of Strips. +When the LED blinks, move the magnet away. Repeat 3 times in total within 10 seconds. + +3. A long LED blink indicates that the remove process was successful. + Strips Guard is an ultra-thin magnetic sensor designed to monitor windows and doors for your safety. It´s so thin that it can be mounted invisibly in the tiny gap between the frame and the door or window. +It is as easy to mount as a sticker using Strips's adhesive tape. +Strips Guard is Z-Wave plus compliant and can be used with any existing Z-Wave smarthome systems. + Strips-MaZw + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3388/Strips Guard EU R3.pdf + CEPT (Europe) / U.S. / Canada / Mexico / CEPT (Europe) / U.S. / Canada / Mexico / CEPT (Europe) / U.S. / Canada / Mexico / U.S. / Canada / Mexico / CEPT (Europe) / CEPT (Europe) / CEPT (Europe) / U.S. / Canada / Mexico / Australia / New Zealand / India + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1510/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1753/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1790/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1862/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1863/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2073/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2080/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2144/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2146/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2827/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3296/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3297/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3369/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3388/xml + + + + + + Set Notification type. + + + + + + Set Led indication. + + + + + + + + + + + diff --git a/openzwave/sensative/stripscomfort.xml b/openzwave/sensative/stripscomfort.xml new file mode 100644 index 00000000..c5a80a85 --- /dev/null +++ b/openzwave/sensative/stripscomfort.xml @@ -0,0 +1,118 @@ + + + http://www.openzwave.com/device-database/019A:000A:0003 + images/sensative/stripscomfort.png + https://products.z-wavealliance.org/products/3391/ + CEPT (Europe) / U.S. / Canada / Mexico / CEPT (Europe) / U.S. / Canada / Mexico / U.S. / Canada / Mexico / CEPT (Europe) / CEPT (Europe) / U.S. / Canada / Mexico / CEPT (Europe) / U.S. / Canada / Mexico / Australia / New Zealand / Japan / India + Set your controller to add mode (see your controller’s manual). Follow the instruction for Wake up. A long LED blink indicates that the add/remove was successful. + 11 02 015 + Strips-Multi-sensor + You may need to reset Strips if your Z-Wave controller is missing or not responding. + +Follow the instructions for “Wake up”, but on the 3rd repetition, leave the magnet at the rounded edge for 10 seconds. A long LED signal indicates success. + Set your controller to remove mode (see your controller’s manual). Follow the instruction for Wake up. A long LED blink indicates that the add/remove was successful. + Wake up Strips manually for Z-Wave communication. Place the magnet at the rounded edge. When the LED blinks, move the magnet away. Repeat twice within 10 seconds. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3391/Strips Multi-Sensors EU manuals.pdf + Strips, the ultra-thin multi sensor is now available in two new sensor models, Strips Drip and Strips Comfort. Drip and Comfort join Strips Guard, the thinnest magnet sensor in the world detecting if your windows are open and closed invisibly since 2015. + +Strip Drip sends an alarm signal if it detects a water leak. Its unique design allows it to be easily placed almost everywhere, including most places other sensors simply can’t fit. With soaking pads integrated in the mounting plate even small amounts of water will be detected. The built-in temperature sensor gives the possibility to combine the leakage alarm with a freeze alarm. There is also a built-in ambient light sensor that may be useful in special applications. + +Strips Comfort is a very accurate temperature and ambient light sensor. The unique design and mounting plate makes it easy to place almost invisibly in your home to measure temperature or control heating, air conditioning and even windows blinds which are connected to your Z-Wave smart home system. + +All Strips products can be used both in-doors and out-doors and the integrated custom battery gives Strips an expected lifetime of up to 10 years. For you, this means no hassle needing to change or charge batteries in your Strips sensors for the lifetime of the products! + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2415/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2443/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2737/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2755/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2941/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2942/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3250/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3259/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3346/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3347/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3370/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3390/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3391/xml + + + + + + + Led alarm reporting + + + + + Temperature and light reporting + + + + + Does not affect temperature alarms + + + + + Temperature reporting unit + + + + + Temperature alarms + + + + + + -20 to 60C + + + + + -20 to 60C + + + + Ambient light reporting + + + + + + + 3 to 64000 + + + + + 1 to 42000 + + + + Leakage alarm + + + + + + 1 to 100 (1 = almost dry, 100 = wet) + + + + + 0-120 (Hours between reports) + + + + + + + + + + diff --git a/openzwave/sercomm/sw-clp01-eu.xml b/openzwave/sercomm/sw-clp01-eu.xml new file mode 100644 index 00000000..823bf12e --- /dev/null +++ b/openzwave/sercomm/sw-clp01-eu.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/0151:0001:0002 + images/sercomm/sw-clp01-eu.png + https://products.z-wavealliance.org/products/927/ + SW-CLP01-EU + Clamp Power Meter + CEPT (Europe) + Z-Wave Clamp Power Meter + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/927/xml + + + diff --git a/openzwave/shenzen_neo/ls01ch.xml b/openzwave/shenzen_neo/ls01ch.xml new file mode 100644 index 00000000..5726fe7a --- /dev/null +++ b/openzwave/shenzen_neo/ls01ch.xml @@ -0,0 +1,28 @@ + + + + + + This parameter defines the on/off status of relay needs saving or not. The status will be saved when relay status is changed if this parameter is set to '1'. Otherwise the relay status is not saved. The Light Switch will restore the relay On/Off status when it's powered again. + + + + + This parameter defines the back light state of the touch button. + + + + + This Parameter defines the relay state. The led will be turned on with pink color when the button is touched to turn on relay if this parameter is set to '1'. Otherwise the LED is off. + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/shenzen_neo/ls02ch.xml b/openzwave/shenzen_neo/ls02ch.xml new file mode 100644 index 00000000..03eb1ab1 --- /dev/null +++ b/openzwave/shenzen_neo/ls02ch.xml @@ -0,0 +1,39 @@ + + + + + + + This parameter defines the back light state of the touch button. The back light led would be on when Light Switch is powered on if the parameter is set to '1'. Otherwise the back light led would be off. + + + + + This parameter defines the relays state. The led will be turned on with pink color when the button is touched to tur on relay if this paramtere is set to '1'. Otherwise the ledstate is not changed. + + + + + This parameter defines the on/off status of relay needs to be saved. The status will be saved when relay status is changed if this parameter is set to '1'. Otherwise the relay stataus is not saved. The Light Switch will restore the relay On/Off status when powered again. + + + + + This parameter defines which endpoint is mapped to root device (Endpoint 0). 0 - No endpoint is mapped to root device. 1 - Endpoint 1 is mapped to root device. 2 - Endpoint 2 is mapped to root device. 3 - Both endpoint 1 and 2 are mapped to root device. + + + + + + + + + + + + + + + diff --git a/openzwave/shenzen_neo/ls03ch.xml b/openzwave/shenzen_neo/ls03ch.xml new file mode 100644 index 00000000..3d86dfa1 --- /dev/null +++ b/openzwave/shenzen_neo/ls03ch.xml @@ -0,0 +1,49 @@ + + + + + https://www.szneo.com/en/products/show.php?id=237 + images/shenzen_neo/ls03ch.jpg + Prepaire z-wave controller for inclusion and press any button 3 times within 1.5 seconds to start the pairing process + Prepaire z-wave controller for exclusion and press any button 3 times within 1.5 seconds to start the exclusion process + 3 gang lightswitch EU 868.42 MHz + + Initial Release + + + + + + This parameter defines the back light state of the touch button. The back light led would be on when Light Switch is powered on if the parameter is set to '1'. Otherwise the back light led would be off. + + + + + This parameter defines the relays state. The led will be turned on with pink color when the button is touched to tur on relay if this paramtere is set to '1'. Otherwise the ledstate is not changed. + + + + + This parameter defines the on/off status of relay needs to be saved. The status will be saved when relay status is changed if this parameter is set to '1'. Otherwise the relay stataus is not saved. The Light Switch will restore the relay On/Off status when powered again. + + + + This parameter defines which endpoint is mapped to root device (Endpoint 0). 0 - No endpoint is mapped to root device. 1 - Endpoint 1 is mapped to root device. 2 - Endpoint 2 is mapped to root device. 3 - Both endpoint 1 and 2 are mapped to root device. + + + + + + + + + + + + + + + + diff --git a/openzwave/shenzen_neo/nas-ab01z.xml b/openzwave/shenzen_neo/nas-ab01z.xml new file mode 100644 index 00000000..67dd116b --- /dev/null +++ b/openzwave/shenzen_neo/nas-ab01z.xml @@ -0,0 +1,149 @@ + + + http://www.openzwave.com/device-database/0258:0088:0003 + images/shenzen_neo/nas-ab01z.png + https://products.z-wavealliance.org/products/1962/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2171/Siren User Manual Common V3_2.pdf + You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time + Loud alarm sound (up to 105dB) with flashing LED's when triggered.Mounts anywhere- it's wireless and 100% battery powered with 1-year battery life (2 CR123A Batteries Included). + +1.Make sounds and lighting when alarm is triggered + +2.Compatible with 300 series and 500 series. + +3.Range:Up to 50m outdoor :Up to 30m indoor + +4.Standby current :87uA + +5. Continuous work :1400 times + 1. Remove the siren cover. +2. Make sure the siren is powered. +3. Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or +gateway operating manual) +4. Press the button three times within 1.5 second, the device will enter inclusion mode. And the +LED will flash on and off alternately five times. +Note: If siren has not been added to Z‐wave network, the siren will enter inclusion mode +automatically when it is powered on. You should let the controller enter into inclusion first +before power on the siren in order to run this function. + Reset procedure will delete all information on the Z‐Wave network and Z‐Wave controller or +Z‐Wave Gateway, and restore the siren to factory default settings. +1. Remove the device cover. +2. Make sure the siren is powered. +3. Press and hold the button for 10 seconds, led will blink once. +4. Release the button. + +Note: to use the reset procedure only when the primary controller is missing or inoperable. + Siren Alarm + In the front casing, there is button that is used to carry out include, exclude or reset factory +default settings on PCB Board. +When power is first supplied, the LED will flash on and off alternately at one second intervals +within 5 seconds if the detector has not been added a Z‐Wave network. Please get familiar with +the terms below before starting the operations. +This product can be included and operated in any Z‐Wave network with other Z‐Wave certified +devices from other manufacturers and/or other applications. All non‐battery operated nodes +within the network will act as repeaters regardless of vendor to increase reliability of the +network. + NAS-AB01Z + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1962/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2171/xml + + https://products.z-wavealliance.org/products/2171/ + NAS-AB01Z + CEPT (Europe) + + + + + + + This parameter defines the output volume when siren plays door bell music. + Door Bell music volume is divided into 3 stages + + + + + + + + This Parameter defines the alarm music duration time when siren receive an alarm sensor notification report or an alarm command from controller. + The duration time is divided into 5 stages. + + + + + + + + + This parameter defines the door bell music duration time when siren receives a door/window sensor notification report or an alarm command (BASIC_SET = 0x02) from controller. + The door bell music will be played always if this parameter is set to 255. + The door bell music will not be played if this parameter is set to 0. + Other values are the door bell music playing duration time. + + + This parameter defines the output volume when siren plays alarm music. + Door Bell music volume is divided into 3 stages + + + + + + This parameter defines the alarm music index for siren play different music when alarm occurs. + There are 10 different music for user selection + + + + + + + + + + + + + This parameter defines the door bell music index for siren play different music when alarm occurs. + There are 10 different music for user selection. + + + + + + + + + + + + + This parameter defines the default music index, volume and the duration time for 3 siren on. + This parameter can be selected between ALARM MUSIC and DOOR BELL MUSIC. + The settings for ALARM MUSIC MODE defines by Param #1, #2 and #5. + The settings for DOOR BELL MUSIC MODE defines by Param #3, #4 and #6 + + + + + This parameter defines the default led enable status when siren is on for ALARM MUSIC MODE + + + + + This parameter defines the default led enable status when siren is on for DOOR BELL MUSIC MODE + + + + + + + + + + + + + diff --git a/openzwave/shenzen_neo/nas-ds01z.xml b/openzwave/shenzen_neo/nas-ds01z.xml new file mode 100644 index 00000000..bc01ea0d --- /dev/null +++ b/openzwave/shenzen_neo/nas-ds01z.xml @@ -0,0 +1,80 @@ + + + http://www.openzwave.com/device-database/0258:0082:0003 + images/shenzen_neo/nas-ds01z.png + https://products.z-wavealliance.org/products/1668/ + NAS-DS01Z + Door Sensor + Manual Wakeup the Sensor + +You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time. + U.S. / Canada / Mexico + Note: to use the reset procedure only when the primary controller is missing or inoperable. + +Restore the Sensor (Door/Window detector) to Factory Default Settings + +Reset procedure will delete all information on the Z-Wave network and Z-Wave controller or Z-Wave Gateway, and restore the sensor to factory default settings. +1.Remove the device cover. + +2.Make sure the sensor is powered. + +3.Press and hold the button for 10 seconds, + +4.Release the button. + + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1782/Door-Window User Guide.doc + This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. + +In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board. + +When power is first supplied, the LED will flash on and off alternately at one second intervals within 5 seconds if the detector has not been added a Z-Wave network. Please get familiar with the terms below before starting the operations. + Add the Sensor (Door/Window detector) to Z-Wave Network + +1.Remove the sensor cover. + +2.Make sure the sensor is powered. + +3.Set Z-Wave controller or Z-Wave gateway into inclusion mode (Refer to the controller or gateway operating manual) +4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times. + + Delete the Sensor (Door/Window detector) from Z-Wave Network + +1.Remove the device cover. + +2.Make sure the sensor is powered. + +3.Set Z-Wave controller or Z-Wave gateway into exclusion mode (Refer to the controller or gateway operating manual) +4.Press the button three times within 1.5 second, the device will enter exclusion mode. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1668/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1782/xml + + https://products.z-wavealliance.org/products/1782/ + NAS-DS01Z + CEPT (Europe) + + + + + + This configuration parameter that can be used to adjust the amount of delay before the OFF command is transmitted. This parameter can be configured with the value of 0 through 65535, where 0 means send OFF command immediately and 65535 means 65535 seconds of delay. + + + Basic Set Command will be sent where contains a value when the door/window is opened or closed, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be. + + + + + + + + + + + + + diff --git a/openzwave/shenzen_neo/nas-pd01z.xml b/openzwave/shenzen_neo/nas-pd01z.xml new file mode 100644 index 00000000..33c6d1cd --- /dev/null +++ b/openzwave/shenzen_neo/nas-pd01z.xml @@ -0,0 +1,121 @@ + + + http://www.openzwave.com/device-database/0258:0083:0003 + images/shenzen_neo/nas-pd01z.png + https://products.z-wavealliance.org/products/1671/ + U.S. / Canada / Mexico + 1.Remove the device cover. + +2.Make sure the sensor is powered. + +3.Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or gateway operating manual) +4.Press the button three times within 1.5 second, the device will enter exclusion mode. + Reset procedure will delete all information on the Z‐Wave network and Z‐Wave controller or Z‐Wave Gateway, and restore the sensor to factory default settings. +1.Remove the device cover. + +2.Make sure the sensor is powered. + +3.Press and hold the button for 10 seconds, Led will blink once. + +4.Release the button. + +Note: to use the reset procedure only when the primary controller is missing or inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1920/Motion Detector User Guide EU V3.3.pdf + Motion Sensor (PIR) + 1.Remove the sensor cover. + +2.Make sure the sensor is powered. + +3.Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or gateway operating manual) +4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times. + This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. + +In the Back casing, there is a button that is used to carry out include, exclude, wake up device or reset factory default settings. + +When power is first supplied, the LED will flash on and off alternately at one second intervals within 5 seconds if the detector has not been added a Z‐Wave network. Please get familiar with the terms below before starting the operations. + NAS-PD01Z + You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1671/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1920/xml + + https://products.z-wavealliance.org/products/1920/ + NAS-PD01ZE + CEPT (Europe) + + + + + + This parameter defines the sensitivity of PIR detector, it is recommended to test the detector with movements from a farthest end of the coverage area at first time of use. + If movements cannot be detected sensitively, simply adjust the sensitivity level with this parameter. + This Parameter can be configured with the value 8 trough 255, where 8 means high sensitivity and 255 means lowest sensitivity. + + + + This parameter can be determined how long the associated devices should stay ON status. + For instance, this parameter is set to 30(second), the PIR detector will send a BASIC_SET Command to an associated device with value basic set level if PIR detector is triggered and the associated device will be turned on 30(second) before it is turned off. + This Parameter value must be large than Parameter 6#. + If user set this parameter to default by Configure CC, the parameter #6 will be set to default value. + Available Settings:5 to 600(second). + + + + Basic Set Command will be sent where contains a value when PIR detector is triggered, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be. + This Parameter is used to some associated devices. + Available Settings: 0, 1 to 99 or 255. + + + + This parameter can be enabled or disabled the PIR detector detecting function. + + + + + + This parameter can be set a lux level value which determines when the light sensor is activated. + If the ambient illumination level falls below this value and a person moves across or within the detected area , PIR detector will send a Z-Wave ON command(i.e. BASIC_SET (value = parameter 3) to an associated device and activate it. + 0 to 1000(Lux). + + + + This Parameter can be used to adjust the interval of being re-triggered after the PIR detector has been triggered. + This Parameter value must be less than Parameter 2#. + If user set this parameter to default by Configure CC, the parameter #2 will be set to default value. + Available Settings: 1 to 8(s). + + + + This Parameter can be set the light sensor measure ambient illumination level interval time. + NOTE: This Value Must Be less than Wakeup Interval Time. + Available Settings: 60 ~ 36000(second). + + + + If this parameter is set to Enable, and when Lux level less than the value define by parameter #5, PIR detector will send a BASIC_SET command frame(i.e. BASIC_SET (value = parameter 3) to an associated device and activate it. + If Lux Level greater than the value define by parameter #5, PIR detector will not send a BASIC_SET command frame. + + + + + This parameter defines by how much Lux Level must change, in lux, to be reported to the main controller. + + + This parameter can enabled or disable the PIR led blinking function. + + + + + + + + + + + + + + diff --git a/openzwave/shenzen_neo/nas-pd02z.xml b/openzwave/shenzen_neo/nas-pd02z.xml new file mode 100644 index 00000000..a0d9c814 --- /dev/null +++ b/openzwave/shenzen_neo/nas-pd02z.xml @@ -0,0 +1,119 @@ + + + + + images/shenzen_neo/nas-pd02z.png + + Fix parameters for temperature model, based on user feedback https://github.com/OpenZWave/open-zwave/issues/1866 + Add Product Pic Entry + + + + + + + Adapt the sensitivity of the motion detection. + + + + + + + + This parameter can be determined how long the associated devices should stay ON status. + For instance, this parameter is set to 30(second), the PIR detector will send a BASIC_SET Command to an associated device with value basic set level if PIR detector is triggered and the associated device will be turned on 30(second) before it is turned off. + This Parameter value must be large than Parameter 6#. + If user set this parameter to default by Configure CC, the parameter #6 will be set to default value. + Available Settings:5 to 600(second). + + + + + Basic Set Command will be sent, on the associated devices (group 2), where contains a value when PIR detector is triggered, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be. + This Parameter is used to some associated devices. + Available Settings: 0, 1 to 99 or 255. + + + + + + Enable the motion detection (PIR) function. + This parameter does not effect the luminance reporting. + + + + + + + + Define the illumination level value which determines when the 'Illumination switch ON function' is activated. + If the illumination level falls below this value and a person moves across or within the detected area, the motion sensor will switch on the associated device (group 2). + 0 to 1000(Lux). + + + + + + Period after motion detection in which the sensor is insensitive for new motion detection. + This value must be less than the 'Motion detection ON time'. + Available Settings: 1 to 8(s). + + + + + + Determine the time between illumination reports, even when value has not changed. + NOTE: This Value Must Be less than Wakeup Interval Time. + Available Settings: 60 ~ 36000(second). + + + + + + Enable the function to switch on a associated device (group 2) once motion has been detected and the illumination level will be less than the value specified in 'Illumination switch ON level'. + + + + + + + This parameter defines by how much Lux Level must change, in lux, to be reported to the main controller. + + + + This parameter is configured the value that differential between current measured and previous report value. If the differential value larger than the settings, device will report this measured temperature value to nodes associated in lifeline. + + + + This parameter can enabled or disable the PIR led blinking function. + + + + + + The motion detected event can be sent multiple times/only once until device report motion cleared event. + + + + + + This parameter defines the calibrated scale for ambient light intensity. + + + + + + + + + + + + + diff --git a/openzwave/shenzen_neo/nas-pd03z.xml b/openzwave/shenzen_neo/nas-pd03z.xml new file mode 100644 index 00000000..96ed23f4 --- /dev/null +++ b/openzwave/shenzen_neo/nas-pd03z.xml @@ -0,0 +1,117 @@ + + + + + Neo (Coolcam) NAS-PD03Z Motion Sensor (PIR) Version 2 + https://www.szneo.com/en/products/show.php?id=197 + images/shenzen_neo/nas-pd02z.png + Press button in sensor once. If successfull, LED will blink one time. + Set gateway in inclusion mode. Press button in sensor three times. LED will flash red five times and then on and off alternately. + Set gateway in exclusion mode. Press button in sensor three times. LED will flash red five times and then on and off alternately. + Press and hold button the button in sensor for 10-15 seconds. LED will one time first and then five times on and off alternately. Release button. + + Initial version, based on PD02Z file + + + + + + + Adapt the sensitivity of the motion detection where 8 means highest sensibility and 255 lowest. + + + + This parameter can be determined how long the associated devices should stay ON status. + For instance, this parameter is set to 30(second), the PIR detector will send a BASIC_SET Command to an associated device with value basic set level if PIR detector is triggered and the associated device will be turned on 30(second) before it is turned off. + This Parameter value must be large than Parameter 6# - Retrigger interval. + Available Settings:5 to 600(second). + + + + + Basic Set Command will be sent, on the associated devices (group 2), where contains a value when PIR detector is triggered, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be. + This Parameter is used to some associated devices. + Available Settings: 0, 1 to 99 or 255. + + + + + + Enable the motion detection (PIR) function. + This parameter does not effect the luminance reporting. + + + + + + + + Define the illumination level value which determines when the 'Illumination switch ON function' is activated. + If the illumination level falls below this value and a person moves across or within the detected area, the motion sensor will switch on the associated device (group 2). + 0 to 1000(Lux). + + + + + + Period after motion detection in which the sensor is insensitive for new motion detection. + This value must be less than the 'Motion detection ON time'. + Available Settings: 1 to 8(s). + + + + + + Determine the time between illumination reports, even when value has not changed. + NOTE: This Value Must Be less than Wakeup Interval Time. + Available Settings: 60 ~ 36000(second). + + + + + + Enable the function to switch on a associated device (group 2) once motion has been detected and the illumination level will be less than the value specified in 'Illumination switch ON level'. + + + + + + + This parameter defines by how much Lux Level must change, in lux, to be reported to the main controller. + + + + This parameter is configured the value that differential between current measured and previous report value. If the differential value larger than the settings, device will report this measured temperature value to nodes associated in lifeline. + + + + This parameter can enabled or disable the PIR led blinking function. + + + + + + The motion detected event can be sent multiple times/only once until device report motion cleared event. + + + + + + This parameter defines the calibrated scale for ambient light intensity. + + + + + + + + + + + + + diff --git a/openzwave/shenzen_neo/nas-rc01z.xml b/openzwave/shenzen_neo/nas-rc01z.xml new file mode 100644 index 00000000..d1b987d4 --- /dev/null +++ b/openzwave/shenzen_neo/nas-rc01z.xml @@ -0,0 +1,36 @@ + + + + + + + + Basic Set Command will be sent where contains a value when SOS is triggered if group 2 have associated a device such as siren, the receiver will take it for consideration; for instance, if associated siren is received the Basic Set Command (0xFF), the siren will take alarm on. + 0-99 are mapping to Basic Set value (0 - 99). 100 is mapping to Basic Set Value 0xFF. + + + + + This parameter defines the time to clear emergency event after emergency event is triggered when parameter #3 is set to 2. + This parameter is set to 0, the clearing emergency event will not occurred always. + The default value of this parameter is set to 60, means that the emergency event will be cleared after 60 seconds when emergency event is triggered. + + + + + This parameter defines the SOS key function, the SOS key can be configured as emergency event key or central scene notification key. + + + + + + + + + + + + + diff --git a/openzwave/shenzen_neo/nas-wr01z.xml b/openzwave/shenzen_neo/nas-wr01z.xml new file mode 100644 index 00000000..ee1a1936 --- /dev/null +++ b/openzwave/shenzen_neo/nas-wr01z.xml @@ -0,0 +1,127 @@ + + + http://www.openzwave.com/device-database/0258:0087:0003 + images/shenzen_neo/nas-wr01z.png + https://products.z-wavealliance.org/products/1670/ + Add the Device (Smart Plug) to Z‐Wave Network +1.Make sure the sensor is powered. +2.Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or gateway operating manual) +3.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off with green alternately five times within 2 seconds. + U.S. / Canada / Mexico + this power plug is connected to power, not battery powered + This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. + +In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board. + +When power is first supplied, the LED will flash on and off with yellow alternately every 1 second intervals within 5 seconds if the detector has not been added a Z‐Wave network, otherwise the LED will flash on and off 5 times with cyan alternately every 300 millisecond. Please get familiar with the terms below before starting the operations. + +This Plug has function that remembers the relay states, the plug will turn on after power up next time if the plug is turn on before the power cut‐off. + Smart Power Plug + Delete the Device (Smart Plug) from Z‐Wave Network +1.Make sure the sensor is powered. +2.Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or gateway operating manual) +3.Press the button three times within 1.5 second, the device will enter exclusion mode. And the LED will flash on and off with yellow alternately five times within 2 seconds. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1783/Smart-Plug User Guide V2.doc + Note: to use the reset procedure only when the primary controller is missing or inoperable. +Restore the Device (Smart Plug) to Factory Default Settings + +Reset procedure will delete all information on the Z‐Wave network and Z‐Wave controller or Z‐Wave Gateway, and restore the sensor to factory default settings. +1.Make sure the sensor is powered. + +2.Press and hold the button more than 10 seconds until the LED blink with red color. + +3.Release the button. + NAS-WR01Z + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1670/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1783/xml + Correction to Value genre="config" index="2" instance="1" label="Meter Report Interval" max="65536" should be "65535" + + https://products.z-wavealliance.org/products/1783/ + CEPT (Europe) + NAS-WR01Z + + + + + + This parameter defines Disable/Enable meter report measure data to controller. + + + + + This parameter defines interval time (in seconds) that Meter report data to main controller. + + + + This parameter defines maximum current (in Amperes) the plug can provide to load that be connected to plug. + If the current consumed by load is greater than maximum current, the plug will cut off power, and send NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline. Red Led will blink every seconds until current is normal (less than Parameter #3). + You must remove the loader and turn on the Plug (press the button once) to enable current monitor and clear NOTIFICATION ALARM. This parameter value must be great than #4. + If user set this parameter to default by Configure CC, the parameter #4 will be set to default value. + + + + + This parameter defines maximum current (in Amperes), if the current plug provide to load is greater than this parameter, the plug will send over-current notification to the controller and the LED will turn RED, but plug cannot cut-off power. This parameter value must be less than parameter #3. + If user set this parameter to default by Configure CC, the parameter #3 will be set to default value. + + + + + This parameter defines the LED indication Function ON/OFF. + If disabled, then LED indication Function and will always be turn-off, while enabled means LED Function is on. + + + + + + + This parameter defines by how much power consumed must change to be reported to the Z-Wave Controller or Z-Wave Gateway, in percents. If the rate of power consumed change ratio is greater than this parameter, the plug will report the results, voltage, current, power and energy, that plug measure to Z-Wave Controller or Z-Wave Gateway + + + + + This parameter defined the relay status if remember or not. + If remembered, the plug will restore the relay status last power off when the plug supply power next time. + + + + + + + This parameter defines the timer function Enable/Disable. + If disabled, then time switch function is not available. + The time period will be defined in parameter #9. + If enabled, and when turn the plug relay on, the timer in plug start run with time period defined in parameter #9 and the plug will turn the relay off. + + + + + + + This parameter defines the time period that plug time switch off. This parameter can be configured 1 - 65535(in minutes). + If Parameter #8 is enabled, and relay is turn-on, the relay will be turn-off after delay this parameter. + + + + + This parameter defines the button on/off function is enabled or not on the top of the wall plug. + If enabled, users can turn on and off the wall plug by pressing the button on the top of the wall plug. + If disabled, the wall plug cannot be turned on and off by pressing the button. + + + + + + + + + + + + + + diff --git a/openzwave/shenzen_neo/nas-wr01ze.xml b/openzwave/shenzen_neo/nas-wr01ze.xml new file mode 100644 index 00000000..d9116330 --- /dev/null +++ b/openzwave/shenzen_neo/nas-wr01ze.xml @@ -0,0 +1,125 @@ + + + + + http://www.openzwave.com/device-database/0258:1027:0200 + images/shenzen_neo/nas-wr01ze.png + Add the Device (Smart Plug) to Z‐Wave Network +1.Make sure the sensor is powered. +2.Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or gateway operating manual) +3.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off with green alternately five times within 2 seconds. + this power plug is connected to power, not battery powered + This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. + +In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board. + +When power is first supplied, the LED will flash on and off with yellow alternately every 1 second intervals within 5 seconds if the detector has not been added a Z‐Wave network, otherwise the LED will flash on and off 5 times with cyan alternately every 300 millisecond. Please get familiar with the terms below before starting the operations. + +This Plug has function that remembers the relay states, the plug will turn on after power up next time if the plug is turn on before the power cut‐off. + Smart Power Plug + Delete the Device (Smart Plug) from Z‐Wave Network +1.Make sure the sensor is powered. +2.Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or gateway operating manual) +3.Press the button three times within 1.5 second, the device will enter exclusion mode. And the LED will flash on and off with yellow alternately five times within 2 seconds. + Note: to use the reset procedure only when the primary controller is missing or inoperable. +Restore the Device (Smart Plug) to Factory Default Settings + +Reset procedure will delete all information on the Z‐Wave network and Z‐Wave controller or Z‐Wave Gateway, and restore the sensor to factory default settings. +1.Make sure the sensor is powered. + +2.Press and hold the button more than 10 seconds until the LED blink with red color. + +3.Release the button. + NAS-WR01ZE + NAS-WR01ZE + U.S. / Canada / Mexico + + Added metadata, and added US version (type 0100) that is branded "Power Plug" with no model number displayed. There is no matching Z-Wave Alliance database entry. + + + + + + + This parameter defined the relay status if remember or not. + If remembered, the plug will restore the relay status last power off when the plug supply power next time. + + + + + + + This parameter defines the button on/off function is enabled or not on the top of the wall plug. + If enabled, users can turn on and off the wall plug by pressing the button on the top of the wall plug. + If disabled, the wall plug cannot be turned on and off by pressing the button. + + + + + + + This parameter defines the LED indication Function ON/OFF. + If disabled, then LED indication Function and will always be turn-off, while enabled means LED Function is on. + + + + + + + This parameter defines the timer function Enable/Disable. + If disabled, then time switch function is not available. + The time period will be defined in parameter #5. + If enabled, and when turn the plug relay on, the timer in plug start run with time period defined in parameter #5 and the plug will turn the relay off. + + + + + + + This parameter defines the time period that plug time switch off. This parameter can be configured 0 - 32767(in minutes). + If Parameter #4 is enabled, and relay is turn-on, the relay will be turn-off after delay this parameter. + + + + + This parameter defines Disable/Enable meter report measure data to controller. + When device is detected an OCP event or the relay turned on or turned off, device still will report all meter values once if this configuration is disabled. + + + + + + This parameter defines interval time (30-32767 seconds) that Meter report data to main controller . + + + + This parameter defines maximum current (in Amperes) the plug can provide to load that be connected to plug. + If the current consumed by load is greater than maximum current, the plug will cut off power, and send NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline. Red Led will blink every seconds until current is normal (less than Parameter #8). + You must remove the loader and turn on the Plug (press the button once) to enable current monitor and clear NOTIFICATION ALARM. This parameter value must be great than #10. + If user set this parameter to default by Configure CC, the parameter #10 will be set to default value. + + + + + This parameter defines by how much power consumed must change to be reported to the Z-Wave Controller or Z-Wave Gateway, in centiAmperes (1-1600). If the rate of power consumed change ratio is greater than this parameter, the plug will report the results, voltage, current, power and energy, that plug measure to Z-Wave Controller or Z-Wave Gateway + The changed value = [Value] x 0.01A + + + + + This parameter defines maximum current (in Amperes), if the current plug provide to load is greater than this parameter, the plug will send over-current notification to the controller and the LED will turn RED, but plug cannot cut-off power. This parameter value must be less than parameter #8. + If user set this parameter to default by Configure CC, the parameter #8 will be set to default value. + + + + + + + + + + + + diff --git a/openzwave/shenzen_neo/nas-ws02z.xml b/openzwave/shenzen_neo/nas-ws02z.xml new file mode 100644 index 00000000..a8b2ae0b --- /dev/null +++ b/openzwave/shenzen_neo/nas-ws02z.xml @@ -0,0 +1,98 @@ + + + http://www.openzwave.com/device-database/0258:0085:0003 + images/shenzen_neo/nas-ws02z.png + https://products.z-wavealliance.org/products/1788/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1788/Water Leakage Detector User Manual V2.doc + NAS-WS01Z + Add the Sensor to Z-Wave Network + +1.Remove the sensor cover. + +2.Make sure the sensor is powered. + +3.Set Z-Wave controller or Z-Wave gateway into inclusion mode (Refer to the controller or gateway operating manual) + +4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times. + In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board. + +When power is first supplied, the LED will flash on and off alternately at one second intervals within 5 seconds if the detector has been added a Z-Wave network. Please get familiar with the terms below before starting the operations. + +This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. + Water Sensor + Delete the Sensor from Z-Wave Network + +1.Remove the device cover. + +2.Make sure the sensor is powered. + +3.Set Z-Wave controller or Z-Wave gateway into exclusion mode (Refer to the controller or gateway operating manual) + +4.Press the button three times within 1.5 second, the device will enter exclusion mode. + Restore the Sensor to Factory Default Settings + +Note: to use the reset procedure only when the primary controller is missing or inoperable + +Reset procedure will delete all information on the Z-Wave network and Z-Wave controller or Z-Wave Gateway, and restore the sensor to factory default settings. + +1.Remove the device cover. + +2.Make sure the sensor is powered. + +3.Press and hold the button for 10 seconds, led will blink once. + +4.Release the button. + Wakeup the Sensor Manual + +User can press button once to wake-up this sensor to send wakeup notification to controller, the Led will be blink one time. + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1788/xml + + + + + + If this parameter is set to 0, the beep and LED will be turn on always until water leakage is not detected. + + + This Parameter defines beep on/off interval time when water leakage is detected. + + + This parameter defines beep on duration first time when water leakage is detected. + + + This parameter defines beep on duration after fist beep on when water leakage is detected. + + + This parameter defines beep on is enabled or disabled when water leakage is detected. + 0 indicate beep on is disable, but LED will be turned on when water leakage detected. + 1 indicate beep on is enabled, the BEEP and LED will be turned on when water leakage detected. + + + + + + This parameter defines the function than water leakage detect is enabled or disabled. + 0 indicate disable water leakage detect, + 1 indicate enable water leakage detect. + + + + + + Basic Set Command will be sent where contains a value when the leakage is detected, the receiver will take it for consideration; + for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be. + + + + + + + + + + + + + diff --git a/openzwave/shenzen_saykey/sk-3007-05.xml b/openzwave/shenzen_saykey/sk-3007-05.xml new file mode 100644 index 00000000..5b20caef --- /dev/null +++ b/openzwave/shenzen_saykey/sk-3007-05.xml @@ -0,0 +1,60 @@ + + + + https://products.z-wavealliance.org/products/2662:0005:3007 + images/shenzen_saykey/SK-3007-05.png + https://products.z-wavealliance.org/products/2662/ + SK-3007-05 + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/2662/SK-3007-05-Manual_en_20171112.pdf + Curtain Motor Control with external module + The SK-3007-05 curtain motor external module support connect specify motor to Z-Wave system reply. It support control motor open/close/stop and position, meanwhile it can feedback motor position as soon as it stopped. + 1. Connect power line to motor, plug power socket in 220VAC power supply, and Make sure +the device is located within direct range of the Z-Wave controller. +2. Set the controller into the exclusion/remove mode (refer to controllers operating manual). +3. Click the PB-button triple times in 1.5 second, located left side of the motor external box. +4. Curtain motor will be detected and excluded from the Z-Wave network. + China + 1. Connect power line to motor, plug power socket in 220VAC power supply. +2. Press and hold the PB-button excess 10 second. +3. Curtain motor will be reset to factory default and clear Z-Wave included network state. +Please use this procedure only when the network primary controller is missing or otherwise +inoperable. + 1. Connect power line to motor, plug power socket in 220VAC power supply, and Make sure +the device is located within direct range of the Z-Wave controller. +2. Set the controller into the inclusion/add mode (refer to controllers operating manual). +3. Click the PB-button triple times in 1.5 second, located left side of the motor external box. +4. Curtain motor will be detected and included in the Z-Wave network. +[Note] During inclusion, a LED will fast flash red light until inclusion done. If motor not +included in any controller, a LED will slow flash red light constantly. +[Note1] In order to working properly, user should operate curtain open and close once +manually after power up. If lead tail was changed or re-assembling motor, motor tail +reset should be done by configuration command parameter #7 manually. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2662 + + + + + + + Support Set only. Toggle motor direction between reverse and default as send out set command with any value(0x00-0xFF). + + + + + Support Set only. Clear motor lead tail endpoint setting as send out set command with any value(0x00-0xFF). + + + + + Support Set only. Enable manual pull function as send out set command with any value(0x00-0xFF). + + + + + + + + + + diff --git a/openzwave/simon/10002034-13X.xml b/openzwave/simon/10002034-13X.xml new file mode 100644 index 00000000..6d2527e3 --- /dev/null +++ b/openzwave/simon/10002034-13X.xml @@ -0,0 +1,101 @@ + + + http://www.openzwave.com/device-database/0267:0000:0001 + images/simon/10002034-13X.png + https://products.z-wavealliance.org/products/3279/ + 10003034-13X + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3279/991406.pdf + S100 Switch IO (China) + Simon Electronic Switch IO integrated by Electronic Switch that provides power Switch and Rocker that provides Z-Wave communication attributes. + When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to exclude from Z-Wave network or perform an association with other Z-Wave device. +Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton. + +This process does not perform a default reset of configurations. + +Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton. + China + When the pushbutton is released after a press of (20sec<T) the device will perform a factory default values operation, excluding it from network and resetíng the configuration parameters. + +Main LED will perform 1 Blink with 5 sec. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to include from Z-Wave network or perform an association with other Z-Wave device. +Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton. + +This process does not perform a default reset of configurations. + +Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3279/xml + + + + + + false + + + + + + + Used during Association process by Simon Shortcut Switch IO to turn ON the main LED of all devices already associated to this shortcut. + + + + + + + This parameter allows to choose delay from activation request until load activation. + Value 0 - Instantly (default). + Values from 1 to 127 - 1 second to 127 seconds in 1 second resolution. + Values from 128 to 254 - 1 minute to 127 minutes in 1 minute resolution. + + + + + This parameter allows to chose the time that load performs activated after complete an activation process. + Value 0 - Instantly (default). + Values from 1 to 127 - 1 second to 127 seconds in 1 second resolution. + Values from 128 to 254 - 1 minute to 127 minutes in 1 minute resolution. + + + + This parameter allows to choose operating for Main LED as identification at 20%.. + + + + + This parameter locks the pushbutton and wired input actions. + + + + + Parameters, Groups, and Z-Wave status are restored to default (Only writable). + + + + + This parameter allows to chose the time that load performs activated after complete an activation process. + Value 0 - Instantly (default). + Values from 1 to 127 - 1 second to 127 seconds in 1 second resolution. + Values from 128 to 254 - 1 minute to 127 minutes in 1 minute resolution. + + + + + + + true + + + + + + + + + diff --git a/openzwave/simon/10002041-13X.xml b/openzwave/simon/10002041-13X.xml new file mode 100644 index 00000000..92ae5c5d --- /dev/null +++ b/openzwave/simon/10002041-13X.xml @@ -0,0 +1,98 @@ + + + + + + + Activates the Central LED. + + + + + + Sets a delay from activation request until the activation is performed. + 0 Disables custom consumption limit (Default). + 1 to 65535 Sets the power in Watts that is supported (Once the load is over, it is disconnected). + + + + + Sets the beacon intensity, turning ON all Device LEDs al percentage set in this configuration. + 0 Disables the beacon function (Defect). + 1 to 99 (1-100%) sets the intensity of the beacon LEDs. + + + + + This parameter allows to choose delay from activation request until load activation. + Value 0 Instantly (default). + Values from 1 to 127 - 1 second to 127 seconds in 1 second resolution. + Values from 128 to 254 - 1 minute to 127 minutes in 1 minute resolution. + + + + + This parameter allows to chose the time that load performs activated after complete an activation process. + Value 0 - Instantly (default). + Values from 1 to 127 - 1 second to 127 seconds in 1 second resolution. + Values from 128 to 254 - 1 minute to 127 minutes in 1 minute resolution. + + + + This parameter allows to choose operating for Main LED as identification at 20%. + + + + + Write only parameter used to restore configurations or perform a completely restore default. + + + + + Sets the device state after a reset. + + + + + Defines the function performed by the device when keypad is pressed. + + + + + + Write only value that performs a fast blink on Central LED during 5 seconds in order to identify the device when it is installed in a multiple frame. + + + + + Read only Configuration used to report the device state and last value. This value is represented in Hexadecimal. + Byte 0 informs about Load State (0 load is OFF and 1 load is ON). + Byte 1 informs about Load value (0x00 or 0xFF) + + + + + Locks the major part of Hold press effects in order to avoid undesired Z-Wave changes, or restores Default. + 0xFF Hold Press from 2sec to 30 sec does not performs a Node info. + Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network. + + + + + + + + + true + + + + + + + + + diff --git a/openzwave/simon/10002080-13X.xml b/openzwave/simon/10002080-13X.xml new file mode 100755 index 00000000..80b11243 --- /dev/null +++ b/openzwave/simon/10002080-13X.xml @@ -0,0 +1,96 @@ + + + + images/simon/10002080-13X.png + https://products.z-wavealliance.org/products/2669/ + https://products.z-wavealliance.org/ProductManual/File?filename=MarketCertificationFiles/2669/ROLLERBLIND_991025_990913.pdf + S100 Rocker iO for Roller Blind + + Added support for Simon S100 Rocker iO roller blind. + + + + + + + Used during Association process by Simon Shortcut Switch IO to turn ON the main LED of all devices already associated to this shortcut. + + + + + + + + This parameter allows to choose the roller blind UP time in seconds. + Value 0 - Instantly (default). + Values from 1 to 127 - 1 second to 127 seconds in 1 second resolution. + + + + + + This parameter allows to choose the roller blind DOWN time in minutes. + Values from 1 to 127 - 1 minute to 127 minutes in 1 minute resolution. + + + + + This parameter allows to choose behaviour of LED in repose + + + + + + This parameter locks the direct control of load. + + + + + + Parameters, Groups, and Z-Wave status are restored to default (Only writable). + + + + + Write only value that performs a fast blink on Central LED during 5 seconds in order to identify the device when it is installed in a multiple frame. + + + + + + Read only Configuration used to report the device state and last value. This value is represented in Hexadecimal. + Byte 0 informs about Load State (0 load is OFF and 1 load is ON). + Byte 1 informs about Load value (0x00 or 0xFF) + + + + + + Reports whether the roller blind needs calibration. + 0x00 Calibration is not required. + 0xFF It is necessary to calibrate the dimmer to work properly. + + + + + This parameter allows to choose the roller blind operating mode (window shutter or sundblinds). + + + + + + This parameter allows to choose the long press behaviour. + + + + + + + + + + + diff --git a/openzwave/smartthings/pgc401m.xml b/openzwave/smartthings/pgc401m.xml new file mode 100644 index 00000000..5a02e2b3 --- /dev/null +++ b/openzwave/smartthings/pgc401m.xml @@ -0,0 +1,15 @@ + + + http://www.openzwave.com/device-database/0150:0191:0001 + images/smartthings/pgc401m.png + https://products.z-wavealliance.org/products/878/ + http://www.smartthings.com/ + SmartThings Hub + Hub to connect SmartThings and Z-Wave devices to the SmartThings cloud. + U.S. / Canada / Mexico + PGC401M + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/878/xml + + + diff --git a/openzwave/smartthings/sth-eth200.xml b/openzwave/smartthings/sth-eth200.xml new file mode 100644 index 00000000..3e9d7ece --- /dev/null +++ b/openzwave/smartthings/sth-eth200.xml @@ -0,0 +1,38 @@ + + + http://www.openzwave.com/device-database/0150:0006:0002 + images/smartthings/sth-eth200.png + https://products.z-wavealliance.org/products/1446/ + Samsung SmartThings Hub + STH-ETH200 + Whether you have two smart devices or 200, all you need is one Hub to create a smart home. Like a live-in translator, the Hub communicates with all of your different connected products–regardless of their wireless protocol– so that you can easily monitor and control them from the SmartThings app. + + +• Compatible with hundreds of smart home products + +• Contains ZigBee and Z-Wave radios, and is also compatible with IP-accessible devices + +• Enables live video recording and event-based video clip recording + +• Contains replacement backup batteries that allow it to continue operating in the event of a power outage + +• Local app processing enables faster operating time + +• No hard wiring or tricky installation needed + +• Simply attach the power supply to the back of the Hub and plug the Ethernet cable in to your Internet router. Easy peasy. + + U.S. / Canada / Mexico + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1446/ST_HUB_QSG_Grayscale.pdf + In the SmartThings mobile app, open the menu in the upper right corner and tap "My Locations." Tap the gear icon at the top right of your Hub's location to access the location settings. Scroll down and check that your Hub is listed as "Active" in the Hubs section. Also check that the LED indicator on the front of the Hub is a solid green and not blinking. + +At the bottom of the location settings, tap the red "Remove Location" button and confirm the removal. This will delete your location, including all devices, settings, and SmartApps. Your Hub will be reset back to a factory default state and you will need the claim code that came with your Hub to re-connect it to SmartThings. + In the SmartThings mobile app, open the menu in the upper right corner and tap "Connect New Device." Then, tap "Connect Now." + In the SmartThings mobile app's "Things" tab, tap the name of the device to show the device details. Then, open the menu in the upper right and tap "Remove." + +Alternatively, open the menu in the upper right corner and tap "My Locations." Tap the gear icon at the top right of your Hub's location to access the location settings. Scroll down to the "Hubs" section and tap on your Hub's name, then tap "Z-Wave Utilities." Tap "General Device Exclusion" and then the "Remove" button to confirm. The hub will enter exclude mode. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1446/xml + + + diff --git a/openzwave/somfy/1811265_ZRTSI.xml b/openzwave/somfy/1811265_ZRTSI.xml new file mode 100644 index 00000000..3df6575f --- /dev/null +++ b/openzwave/somfy/1811265_ZRTSI.xml @@ -0,0 +1,17 @@ + + + + + + + + + + + + + + diff --git a/openzwave/steinel/is140-2.xml b/openzwave/steinel/is140-2.xml new file mode 100644 index 00000000..a36e1733 --- /dev/null +++ b/openzwave/steinel/is140-2.xml @@ -0,0 +1,156 @@ + + + http://www.openzwave.com/device-database/0271:1A72:0002 + images/steinel/is140-2.png + https://products.z-wavealliance.org/products/2310/ + IS 140-2 Z-Wave + 40111677001 + CEPT (Europe) + Are you toying with the idea of fitting a motion detector to your building? The infrared controlled IS 140-2 motion detector gives you all the benefits of a modern detector. Needless to say, we always use the very latest technology for our bestsellers too. For instance, we have given the product in its current generation even more class: larger adjustment angle, even longer reach and even better detection performance. Treat your home to intelligent sensor technology. + +Smart home included. +The optional Smart Friends box and the free Smart Friends app make it easy to set the motion detector via smart phone or tablet. The light connected can also be switched ON or OFF via app. Other Steinel products can also be interconnected. If you wish, this also works via remote control when you are out. That completes your own light management system. +Along with STEINEL products, Smart Friends solutions from PAULMANN, SCHELLENBERG and ABUS can also integrated. Smart homes from a brand-name provider. + Exclusion = Remove + +To start the motion detector's exclusion mode, turn the device's control dial (E) to "Set" and back to "0" within 5 seconds. + +Removing IS 140-2 from the Smart Friends system: +1) In the rooms view, activate the edit mode. +2) Select the device in the chosen room and press the "delete" button. Press delete and follow the instructions in the app. +3) To put the device into exclusion mode, turn the device's control dial (E) to "Set" and back to "0" within 5 seconds. The red status LED (F) lights up to show that this mode is selected. +4) The app displays a confirmation message once exclusion has been successfully completed. + Resetting IS 140-2 to factory settings: + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + +1) Turn the device's control dial (E) to "Set" and move it to "Reset" within 5 seconds. +2) The status LED (F) briefly flashes to show that the light has been reset. +3) The device is now no longer included in the Z-Wave system and has been returned to factory settings. + Inclusion = Add + +To start the motion detector's inclusion mode, turn the device's control dial (E) to "Set" and back to "0" within 5 seconds. + +Adding IS 140-2 to the Smart Friends system: +1) Download the Smart Friends app from the app store. +2) In the rooms view, activate the edit mode. +3) Select the chosen room and press the "Add device" button. +4) To put the device into inclusion mode, turn the device's control dial (E) to "Set" and back to "0" within 5 seconds. The status LED (F) lights up to show that this mode is selected. +5) The app displays a confirmation message once inclusion has been successfully completed. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2310/IS140-2Z-Wave_5spr_110050437_11.04.17.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2310/xml + + + + + + + + Available settings: 5-900 seconds. + + + + + 2000 - is used as daylight (always night mode). + 0 - run Learn ambient light sequence. 2-1999 lux. + + + + + Potentiometer State. + Available settings: 2-100%. + + + + External ambient light value. + + + + + Disable local control. + + + + + + + + + Off behaviour (timeout). + 0 - Lamp is switched off and remains so until any new motion event (local or remote) is received. + 1 to 100 (Default) timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 Lamp is switched off for TIME (cfg 1). + It does not wait for a motion event and works normally via current motion evaluation. + + + + + On behaviour (timeout). + Similar than Off behaviour. + Available settings: 0-255. + 0 - Lamp is switched on and remains so until any new motion event (local or remote) is received. + It then works normally via current motion evaluation. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. + + + + + On behaviour time over (timeout). + Available settings: 0-255. + 0 No additional waiting for motion. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 Never stop waiting before motion. + + + + + Available settings: 0-255. + 0 - Lamp is switched off and remains so until any new motion event (local or remote) is received. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 device ignores ON - OFF sequence and uses OFF behavior. + + + + Available settings: 0-255. + 0 - Lamp is switched on and remains so until any new motion event (local or remote) is received. + It then works normally via current motion evaluation. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 device ignores OFF - ON sequence and uses ON behaviour. + + + + + Available settings: 10-50. + + + + + Available settings: 0-255. + 0 (Default) BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still enabled. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still disabled + + + + + + + + + + + + + diff --git a/openzwave/steinel/l810-led-ihf.xml b/openzwave/steinel/l810-led-ihf.xml new file mode 100644 index 00000000..0e06b78b --- /dev/null +++ b/openzwave/steinel/l810-led-ihf.xml @@ -0,0 +1,243 @@ + + + http://www.openzwave.com/device-database/0271:1A75:0001 + images/steinel/l810-led-ihf.png + https://products.z-wavealliance.org/products/2309/ + 50111677301 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2309/110050438 BDAL L 810 LED IHF SMARTHOME D-GB-F-I-NL.pdf + A high-quality product is cleverly thought through and made from materials that last. Its value also extends beyond today, it has permanency and constancy. The L 810 iHF outdoor SensorLight is an LED uplight and downlight that translates intelligent technology into form and function. For the first time, we have managed to make a light's sensor completely invisible – without compromising on first-class design and technological perfection. For stunning upward and downward lighting. New: optional manual override for 4 hours. + +Smart home included. +The optional Smart Friends box and the free Smart Friends app make it easy to set the L 810 LED iHF Z-Wave via smart phone or tablet. The light can also be switched ON or OFF via app. Other Steinel products can also be interconnected. If you wish, this also works via remote control when you are out. That completes your own light management system. +Along with STEINEL products, Smart Friends solutions from PAULMANN, SCHELLENBERG and ABUS can also integrated. Smart homes from a brand-name provider. + CEPT (Europe) + L 810 LED iHF Z-Wave + Inclusion = Add +To start the light's inclusion mode, briefly press button (8) + +Adding L 810 LED iHF to the Smart Friends system: +1) Download Smart Friends app from the App Store. +2) In the rooms view, activate the edit mode. +3) Select the chosen room and press the "Add device" button. +4) Briefly press the device's button (8) to set the light to inclusion mode. The status LED (12) lights up to show that this mode is selected. +5) The app displays a confirmation message once inclusion has been successfully completed. + Returning L 810 LED iHF to factory settings: + +Please only perform these steps if the main network controller is missing or not working for other reasons. + +1) Briefly press button (8) and directly afterwards keep it pressed for 5 seconds. +2) Status LED (12) briefly flashes to show that the light has been reset. +3) The device is now no longer included in the Z-Wave system and has been returned to factory settings. + Exclusion = Remove +To start the light's exclusion mode, briefly press button (8) + +Removing L 810 LED iHF from the Smart Friends system: +1) In the rooms view, activate the edit mode. +2) Select the device in the chosen room and press the "delete" button. Press delete and follow the instructions in the app. +3) Briefly press the device's button (8) to set the light to exclusion mode. The red status LED (12) lights up to show that this mode is selected. +4) The app displays a confirmation message once exclusion has been successfully completed. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2309/xml + + + + + + + Range: 1-99 (default: 99). + + + + + Range: 5-900 (default: 180 seconds). + + + + + Range: 2-2000, 0 (default: 2000 lux / potentiometer state if present). + 0 - run Learn ambient light sequence. + 2-1999 - threshold [lux]. + 2000 - is used as daylight (always night mode). + + Value can be controlled via potentiometer (if present on device) - potentiometer value is then used as the default value and any potentiometer movement rewrites the current setting. + + + + + Range: 0-60, -1 (default: 0 / potentiometer state if present). + 0 - off (dim = basic light completely disabled). + 1-60 - time [minutes] (enabled in night mode, starts after lamp is switched off after motion detection). + 255 (-1) - whole night (dim through the whole night when lamp is off). + + Dim mode is also disabled when local control is disabled as well as in Slave imode. + + + + + Range: 100-500 (default: 500 cm / potentiometer state if present). + + Value can be controlled via potentiometer (if present on device) - potentiometer value is then used as default value and any potentiometer movement rewrites the current setting. + + + + + Range: 2-100 (default: 100 % / potentiometer state if present). + + Value can be controlled via potentiometer (if present on device) . potentiometer value is then used as the default value and any potentiometer movement rewrites the current setting. + + + + + Range: 5-120, 0 (default: 0, disabled). + 5-120 - Interval for ambient light measuring when lamp is on (lamp switches off shortly and measures). + 0 - function is off. + + + + + Range: 0/1 (default: 1, disabled). + + When GLOBAL_LIGHT mode is ON - device overrides its own light sensor values and uses Light Report values from any Z-Wave light sensor instead - this has to be configured appropriately to send light automatically. If the last remote light level value is older than 30 minutes, the internal light value is used again until the next external value is receive. + + + + + + + Range: 0-4 (default: 2, Normal mode with lifeline error signalisation). + "Stupid mode" - lamp permanently on (bit 2 = 1): + - has higher priority then slave mode. + - lamp/relay is permanently on (for simple power wall switch controlling). + + Slave mode without gateway checking (bit 0 = 1): + - only if included in Z-Wave network. + - useful for controlling via third-party sensor. + - lamp/relay is directly controlled via Z-Wave, internal sensors are not used for controlling it. + + Central unit checking (bit 1 = 1): (useful especially for controlling via gateway) + When slave bit is 0: + - device signalises fail of lifeline connection (if this bit is zero, fail of lifeline connection is not signalised). + When slave bit is 1: + - device checks presence of Z-Wave device in lifeline group (gateway). + If it is not present for 2 minutes (testing repeatedly every 30 seconds) device switches to normal mode in the same way as after the end of local disabled mode (ON_BEHAVIOUR). + - the device checks every 1 minute for recovery of lifeline connection. + - if no lifeline specified - it works in normal mode. + + Be careful with this option, device stops using its own motion sensor in Slave and "Stupid" mode. + + + + + + + + + + Behaviour after BASIC OFF (and similar commands). If a transition (even with zero change) with a non-default duration is to be processed, the transition cannot be interrupted by any motion event in any case. + + Range: 0-209, 255 (default: 10 seconds). + 0 - Lamp is switched off and remains so until any new motion event (local or remote) is received. + 1-209 - Lamp/Relay is switched off and remains so until after a specified timeout once a new motion event (local or remote) is received. + Timeout: + 1..100 - 1 second (1) to 100 seconds (100) in 1-second resolution. + 101..200 - 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201..209 - 1 hour (201) to 9 hours (209) in 1-hour resolution. + 210-254 - reserved. + 255 - Lamp is switched off for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation. + + + + + Behaviour after BASIC ON (and similar commands). If a transition (even with zero change) with a non-default duration is to be processed, the transition cannot be interrupted by any motion event in any case. + + Range: 0-209, 255 (default: 255). + 0 - Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. + 1-209 - Lamp/relay is switched on and remains so until after a specified timeout once a new motion event (local or remote) is received. It then works normally via current motion evaluation. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. + Timeout: + 1..100 - 1 second (1) to 100 seconds (100) in 1-second resolution. + 101..200 - 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201..209 - 1 hour (201) to 9 hours (209) in 1-hour resolution. + 210-254 - reserved + 255 - Lamp is switched on for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation. + + + + + Time limit to stop waiting for motion after timeout of ON_BEHAVIOUR or OFF_ON_BEHAVIOUR (0-209) to prevent staying ON forever when there is no motion. + + Range: 0-209, 255 (default: 204, 4 hours). + 0 - No additional waiting for motion. + 1-209 - Timeout: + 1..100 - 1 second (1) to 100 seconds (100) in 1-second resolution. + 101..200 - 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201..209 - 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 - Never stop waiting before motion. + + + + + Behaviour after a rapid sequence of BASIC ON and BASIC OFF commands. The intention is to use a much longer timeout value than the time after a single ON command which should then be followed by a short timeout value. + + Range: 0-209,255 (default: 204, 4 hours). + 0 - Lamp is switched off and remains so until any new motion event (local or remote) is received. + 1-209 - Lamp/Relay is switched off and remains so until after a specified timeout once a new motion event (local or remote) is received. + Timeout: + 1..100 - 1 second (1) to 100 seconds (100) in 1-second resolution. + 101..200 - 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201..209 - 1 hour (201) to 9 hours (209) in 1-hour resolution. + 210-254 - reserved. + 255 - device ignores ON - OFF sequence and uses OFF behavior. + + + + + Behaviour after a rapid sequence of BASIC OFF and BASIC ON commands. The intention is to use a much longer timeout value than the time after a single OFF command which should then be followed by a short timeout value. + + Range: 0-209, 255 (default: 204, 4 hours). + 0 - Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. + 1-209 - Lamp/relay is switched on and remains so until after a specified timeout once a new motion event (local or remote) is received. It then works normally via current motion evaluation. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. + Timeout: + 1..100 - 1 second (1) to 100 seconds (100) in 1-second resolution. + 101..200 - 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201..209 - 1 hour (201) to 9 hours (209) in 1-hour resolution. + 210-254 - reserved + 255 device ignores OFF - ON sequence and uses ON behaviour. + + + + + Time in [100 miliseconds] of maximum delay between BASIC ON and BASIC OFF (and vice versa) to consider this as a sequence. It is typically 1 second, but can be exceptionally longer due to retransmissions and overload - in this case, a longer interval can be allowed (up to 5 seconds). + + Range: 10-50 (default: 10, 1 scond). + + + + + Motion disable timeout after BASIC SET to motion endpoint when the internal motion sensor is not used for evaluating the behaviour of the lamp. Events are, however, still transmitted to the Lifeline, and the device can be controlled via remote motion sensors. + + Range: 0-209,255 (default: 0, disabled). + 0 - BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still enabled. + 1-209 - Internal motion sensor is disabled for specified timeout after BASIC SET 0x00 to motion endpoint. + Timeout: + 1..100 - 1 second (1) to 100 seconds (100) in 1-second resolution. + 101..200 - 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201..209 - 1 hour (201) to 9 hours (209) in 1-hour resolution. + 210-254 - reserved. + 255 - BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still disabled. + + + + + + + + + + + + + diff --git a/openzwave/steinel/rs-led-d2.xml b/openzwave/steinel/rs-led-d2.xml new file mode 100644 index 00000000..04934462 --- /dev/null +++ b/openzwave/steinel/rs-led-d2.xml @@ -0,0 +1,164 @@ + + + http://www.openzwave.com/device-database/0271:1A74:0001 + images/steinel/rs-led-d2.png + https://products.z-wavealliance.org/products/2243/ + Exclusion: Remove + +Removing RS LED D2 from the Smart Friends system: +1 In the rooms view, activate the edit mode. +2. Select the device in the chosen room and press the "delete" button. Press delete and follow the instructions in the app. +3 Briefly press button e on the device to set it to exclusion mode. The red status LED h lights up to show that this mode is selected. +4 The app displays a confirmation message once exclusion has been successfully completed. + + + Sleek, attractive lines. Opting for the RS LED D2 designer indoor luminaire, you'll be giving your home a real designer highlight with pleasant LED illumination. With its stunning looks and intelligent technology, this light provides the last word in stylish home convenience. Once fitted to the wall or ceiling, the high-frequency sensor switches it 'ON' and 'OFF' in complete silence and all automatically. The light is child's play to install and the function settings on the product are easy to understand too. Your neighbours will be amazed. + +Smart home included. +The optional Smart Friends Box and the free Smart Friends app make it easy to set the RS PRO LED D2 Z-Wave via smart phone or tablet. The light can also be switched ON or OFF via app. Other Steinel products can also be interconnected. If you wish, this also works via remote control when you are out. That completes your own light management system. +Along with STEINEL products, Smart Friends solutions from PAULMANN, SCHELLENBERG and ABUS can also integrated. Smart homes from a brand-name provider. + 6772 + RS LED D2 Z-Wave + CEPT (Europe) + Returning RS LED D2 to factory settings: +Please use this procedure only when the network primary controller is missing or otherwise inoperable. +1 Briefly press button e and directly afterwards keep it pressed for 5 seconds. +2 Status LED h briefly flashes to show that the light has been reset. +3 The device is now no longer included in the Z-Wave system and has been returned to factory settings. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2243/RSLEDD2Z-Wave_5spr_110054844_11.04.17.pdf + Inclusion: Add + +Adding RS LED D2 to the Smart Friends system: +1 Download Smart Friends app from the app store. +2 In the rooms view, activate the edit mode. +3 Select the chosen room and press the "Add device" button. +4 Briefly press button 5 on the device to set it to inclusion mode. Status LED 8 lights up to show that this mode is selected. +5 The app displays a confirmation message once inclusion has been successfully completed. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2243/xml + + + + + + + + Duration of light after motion detection in seconds. + + + + + 0 - run Learn ambient light sequence. + 2000 - is used as daylight (always night mode). + Value can also be controlled via potentiometer - potentiometer value is used as the default value. + + + + + Adjust motion sensitivity from 2-100. + Value can also be controlled via potentiometer. Potentiometer value is used as the default value and any potentiometer movement rewrites + the current setting. + + + + + Interval for ambient light measuring when lamp is on ( lamp switches off shortly and measures ). Range 5-120 0=function is off. + + + + + When GLOBAL_LIGHT mode is ON - device overrides its own light sensor values and uses Light report values from any Z-Wave light sensor instead - this has to be configured appropriately to send light + automatically. + If the last remote light level value is older than 30 minutes, the internal light value is used again until the next external value is received. + + + + + Disable local control. + Lamp stops using it's own motion sensor in Slave and Stupid mode. + + + + + + + + + + 0 - Lamp is switched off and remains so until any new motion event (local or remote) is received. + 1 to 100 (Default) timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 Lamp is switched off for TIME (cfg 1). + It does not wait for a motion event and works normally via current motion evaluation. + + + + + + Similar than Off behaviour. + Available settings: 0-255. + 0 - Lamp is switched on and remains so until any new motion event (local or remote) is received. + It then works normally via current motion evaluation. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted only via local motion sensor if enabled. + + + + + Available settings: 0-255. + 0 No additional waiting for motion. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 Never stop waiting before motion. + + + + + Available settings: 0-255. + 0 - Lamp is switched off and remains so until any new motion event (local or remote) is received. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 device ignores ON - OFF sequence and uses OFF behavior. + + + + + Available settings: 0-255. + 0 - Lamp is switched on and remains so until any new motion event (local or remote) is received. + It then works normally via current motion evaluation. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted only via local motion sensor if enabled. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 device ignores OFF - ON sequence and uses ON behaviour. + + + + + Time in [100 miliseconds] of maximum delay between BASIC ON and BASIC OFF (and vice versa) to consider this as a sequence. + It is typically 1 second, but can be exceptionally longer due to retransmissions and overload in this case, a longer interval can be allowed (up to 5 seconds ). + + + + + Available settings: 0-255. + 0 (Default) BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still enabled. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still disabled + + + + + + + + + + + + + diff --git a/openzwave/steinel/xled-home-2.xml b/openzwave/steinel/xled-home-2.xml new file mode 100644 index 00000000..15431ac5 --- /dev/null +++ b/openzwave/steinel/xled-home-2.xml @@ -0,0 +1,169 @@ + + + http://www.openzwave.com/device-database/0271:1A73:0001 + images/steinel/xled-home-2.png + https://products.z-wavealliance.org/products/2290/ + XLED home 2 Z-Wave + 50111677101 + The moveable sensor-switched outdoor floodlight with fully swivelling LED panel in a classy opal look. The XLED home 2 sensor-switched floodlight comes in a sophisticated design. It is not just an eye-catcher, but also a truly talented mover. Thanks to the fully swiveling LED panel, every corner of the entrance area can be illuminated flexibly and as required. The highly efficient LED technology coupled with the opal cover provides maximum lighting comfort. As an individual floodlight or interconnected with the slave version, the innovative new generation of the XLED home success series is available in white, black, graphite and silver. + +Smart home included. +The optional Smart Friends Box and the free Smart Friends app make it easy to set the XLED home 2 Z-Wave via smart phone or tablet. The floodlight can also be switched ON or OFF via app. Other Steinel products can also be interconnected. If you wish, this also works via remote control when you are out. That completes your own light management system. +Along with STEINEL products, Smart Friends solutions from PAULMANN, SCHELLENBERG and ABUS can also integrated. Smart homes from a brand-name provider. + CEPT (Europe) + To put the device into inclusion mode, turn the device's control dial (F) to "Set" and back to "0" within 5 seconds. The status LED (G) lights up to show that this mode is selected. + + +Adding XLED home 2 to the Smart Friends system: +1) Download the Smart Friends app from the app store. +2) In the rooms view, activate the edit mode. +3) Select the chosen room and press the "Add device" button. +4) To put the device into inclusion mode, turn the device's control dial (F) to "Set" and back to "0" within 5 seconds. The status LED (G) lights up to show that this mode is selected. +5) The app displays a confirmation message once inclusion has been successfully completed. + Resetting XLED home 2 to factory settings: + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + +1) Turn the device's control dial (F) to "Set" and move it to "Reset" within 5 seconds. +2) The status LED (G) briefly flashes to show that the light has been reset. +3) The device is now no longer included in the Z-Wave system and has been returned to factory settings. + To put the device into exclusion mode, turn the device's control dial (F) to "Set" and back to "0" within 5 seconds. The red status LED (G) lights up to show that this mode is selected. + + +Removing XLED home 2 from the Smart Friends system: +1) In the rooms view, activate the edit mode. +2) Select the device in the chosen room and press the "delete" button. Press delete and follow the instructions in the app. +3) To put the device into exclusion mode, turn the device's control dial (F) to "Set" and back to "0" within 5 seconds. The red status LED (G) lights up to show that this mode is selected. +4) The app displays a confirmation message once exclusion has been successfully completed. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2290/XLEDhome2Z-Wave_5spr_110050436_11.04.17.LowRes.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2290/xml + + + + + + + + Available settings: 5-900 seconds. + + + + + 2000 - is used as daylight (always night mode). + 0 - run Learn ambient light sequence. 2-1999 lux. + + + + + Potentiometer State. + Available settings: 2-100%. + + + + + Available settings: 0,5-120. + Interval for ambient light measuring when lamp is on (lamp switches off shortly and measures). + 0 - function is off. + + + + External ambient light value. + + + + + Disable local control. + + + + + + + + + Off behaviour (timeout). + Available settings: 0-209,255. + 0 - Lamp is switched off and remains so until any new motion event (local or remote) is received. + 1 to 100 (Default) timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 Lamp is switched off for TIME (cfg 1). + It does not wait for a motion event and works normally via current motion evaluation. + + + + + On behaviour (timeout). + Similar than Off behaviour. + Available settings: 0-209,255. + 0 - Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. + 255 Lamp is switched on for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation. + + + + + On behaviour time over (timeout). + Available settings: 0-209,255. + 0 No additional waiting for motion. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 Never stop waiting before motion. + + + + + Available settings: 0-209,255. + 0 - Lamp is switched off and remains so until any new motion event (local or remote) is received. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 device ignores ON - OFF sequence and uses OFF behavior. + + + + + Available settings: 0-209,255. + 0 - Lamp is switched on and remains so until any new motion event (local or remote) is received. + It then works normally via current motion evaluation. + Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 device ignores OFF - ON sequence and uses ON behaviour. + + + + + Available settings: 10-50. + Time in [100 miliseconds] of maximum delay between BASIC ON and BASIC OFF (and vice versa) to consider this as a sequence. + It is typically 1 second, but can be exceptionally longer due to retransmissions and overload - in this case, a longer interval can be allowed (up to 5 seconds). + + + + + Available settings: 0-209,255. + 0 (Default) BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still enabled. + 1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. + 101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution. + 201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution. + 255 BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still disabled + + + + + + + + + + + + + diff --git a/openzwave/stelpro/stzw402.xml b/openzwave/stelpro/stzw402.xml new file mode 100644 index 00000000..bfdfb7de --- /dev/null +++ b/openzwave/stelpro/stzw402.xml @@ -0,0 +1,64 @@ + + + http://www.openzwave.com/device-database/0239:0001:0001 + images/stelpro/stzw402.png + https://products.z-wavealliance.org/products/1603/ + The thermostat may be manually reset to its factory state. +When this is performed, all parameters are reset to their default values and the thermostat is removed (excluded) from the Z-Wave network. +To reset the thermostat to its default state: +- Enter the advanced settings +- Enter the °STELPRO menu (menu 6) +- Navigate to the “def” screen using the UP or DOWN buttons. +- Enter the “def” menu by pressing the UP and DOWN buttons for less than 3 seconds +- Select “yes” and confirm the selection by pressing the UP and DOWN buttons for less than 3 seconds. +If the thermostat was added (included) in a Z-wave network, it will send a ‘’device reset locally’’ notification. +The thermostat will then reset itself. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + STZW402+ + Ki, the smart home line-voltage thermostat by Stelpro - STZW402+ +• The very first Z-Wave Plus line voltage thermostat in North America +• Supports 120Vac - 240Vac (50/60 Hz) voltages +• Controls baseboard heaters and convectors up to 4000W +• Easy to use 2 button interface +• Made in Canada +• High precision temperature control +/- 0.1 °C +• Z-Wave Plus certified, works with thousands of other Z-Wave devices +• Brings optimal comfort into your smart home +• Can be integrated into smart home automated scenes +• Local keypad lock +• Displays external temperature +• Adjustable backlight intensity +• Comfort and Eco modes +• Celsius or Fahrenheit display +• Quiet TRIAC operation +• Frost-free warning +• Sleek design to harmonize with any decor +• Backed by Stelpro’s 30 years of experience as a leader in the heating market + U.S. / Canada / Mexico + Make sure the Z-Wave hub is in the include mode (Refer to your Z-Wave hub instruction manual). + +To add (include) the thermostat to a Z-Wave network, enter the Menu 1 (Z-Wave menu) and select “On”. Then press the UP and DOWN buttons to start the inclusion process. During inclusion, “On” will be blinking and the connectivity icon will be animated in an increasing pattern. When the inclusion process has been completed, On will be displayed solid. If an error occurs, “Err” will be displayed for 3 seconds then the screen will revert to “Off” selection. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1603/INS_STZW402_1215_EN.pdf + Ki - Electronic Thermostat for Smart Home + Make sure the Z-Wave hub is in the exclude mode (Refer to your Z-Wave hub instruction manual). +To remove (exclude) the thermostat from a Z-Wave network, enter the Menu1 (Z-Wave menu) and select “Off”. Then press the UP and DOWN buttons to start the exclusion process. During exclusion, “Off” will be blinking and the connectivity icon will be animated in an decreasing pattern. When the exclusion process has been completed, Off will be displayed solid. If an error occurs, “Err” will be displayed for 3 seconds then the screen will revert to “On” selection. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1603/xml + + + + + + + + + + + + 0 + + + diff --git a/openzwave/sunricher/srzv9001k12dimz4.xml b/openzwave/sunricher/srzv9001k12dimz4.xml new file mode 100644 index 00000000..9e5d8e90 --- /dev/null +++ b/openzwave/sunricher/srzv9001k12dimz4.xml @@ -0,0 +1,67 @@ + + + + SR-ZV9001 4 Channel Dimmer Remote Control + The remote control is a Z-Wave device that can both control other Z-Wave + devices and activate scenes in Gateways. + + http://www.openzwave.com/device-database/0330:b302:0300 + + https://www.sunricher.com/single-color-z-wave-remote-secondary-controller-sr-zv9001k12-dim-z4.html + + images/sunricher/srzv9001k12dimz4.png + + https://www.sunricher.com/media/resources/manual/SR-ZV9001K12-DIM-Z4%20V2%20Instruction.pdf + + Short press any button to activate the remote control for 3s, and press + and hold down both buttons All On and All Off for over 1 second to activate the remote control for 7s. + + + Step 1. Make sure the remote control does not belong to any Z-Wave network, short press any button, if LED + indicator does not turn on, the remote control does not belong to any network, then continue step 2,if LED + indicator turns on, it means the remote control has already been included to a network, please first set the + remote control to exclusion mode (refer to the part "Exclusion" of this manual),then continue step 2. + Step 2. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual + on how to turn your controller into inclusion). + Step 3. Press and hold down both buttons All On and All Off for over 3 seconds, LED indicator turns on, the + remote control will be set to inclusion mode, and waiting to be included, after 10s LED indicator blinks 6 + times quickly to indicate successful inclusion. The remote control is a sleepy device, after inclusion it + will not enter into sleepy mode immediately, and will continue activation status for 30s and wait data + interaction from the gateway, the LED indicator will stay solid on, please be patient to wait LED indicator + to turn off. + + + There are two exclusion methods: + Method 1: Exclusion from the primary controller/gateway as follows: + 1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual + on how to set your controller into exclusion). + 2. Press and hold down both buttons All On and All Off for over 3 seconds, LED indicator turns on, the + remote control will be set to exclusion mode, and waiting to be excluded, after 7s LED indicator blinks 4 + times quickly to indicate successful exclusion. + Method 2: Factory reset the remote control will force the remote control to be excluded from a network. + (please refer to the part “Factory Reset” of this manual) + + + Press and hold down both buttons All On and All Off for over 10 seconds, LED indicator turns on and then + blinks 4 times quickly to indicate successful factory reset. + + CEPT (Europe) + U.S. / Canada / Mexico + Australia / New Zealand + SR-ZV9001K12-DIM-Z4 + SR-ZV9001K12-DIM-Z4 + SR-ZV9001K12-DIM-Z4 + + Initial Configuration file + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/sunricher/srzv9001k12dimz5.xml b/openzwave/sunricher/srzv9001k12dimz5.xml new file mode 100644 index 00000000..36722f90 --- /dev/null +++ b/openzwave/sunricher/srzv9001k12dimz5.xml @@ -0,0 +1,68 @@ + + + + SR-ZV9001 5 Channel Dimmer Remote Control + The remote control is a Z-Wave device that can both control other Z-Wave + devices and activate scenes in Gateways. + + http://www.openzwave.com/device-database/0330:b301:0300 + + https://www.sunricher.com/single-color-z-wave-remote-secondary-controller-sr-zv9001k12-dim-z5.html + + images/sunricher/srzv9001k12dimz5.png + + https://www.sunricher.com/media/resources/manual/SR-ZV9001K12-DIM-Z5%20V2%20Instruction.pdf + + Short press any button to activate the remote control for 3s, and press + and hold down both buttons All On and All Off for over 1 second to activate the remote control for 7s. + + + Step 1. Make sure the remote control does not belong to any Z-Wave network, short press any button, if LED + indicator does not turn on, the remote control does not belong to any network, then continue step 2,if LED + indicator turns on, it means the remote control has already been included to a network, please first set the + remote control to exclusion mode (refer to the part "Exclusion" of this manual),then continue step 2. + Step 2. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual + on how to turn your controller into inclusion). + Step 3. Press and hold down both buttons All On and All Off for over 3 seconds, LED indicator turns on, the + remote control will be set to inclusion mode, and waiting to be included, after 10s LED indicator blinks 6 + times quickly to indicate successful inclusion. The remote control is a sleepy device, after inclusion it + will not enter into sleepy mode immediately, and will continue activation status for 30s and wait data + interaction from the gateway, the LED indicator will stay solid on, please be patient to wait LED indicator + to turn off. + + + There are two exclusion methods: + Method 1: Exclusion from the primary controller/gateway as follows: + 1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual + on how to set your controller into exclusion). + 2. Press and hold down both buttons All On and All Off for over 3 seconds, LED indicator turns on, the + remote control will be set to exclusion mode, and waiting to be excluded, after 7s LED indicator blinks 4 + times quickly to indicate successful exclusion. + Method 2: Factory reset the remote control will force the remote control to be excluded from a network. + (please refer to the part “Factory Reset” of this manual) + + + Press and hold down both buttons All On and All Off for over 10 seconds, LED indicator turns on and then + blinks 4 times quickly to indicate successful factory reset. + + CEPT (Europe) + U.S. / Canada / Mexico + Australia / New Zealand + SR-ZV9001K12-DIM-Z5 + SR-ZV9001K12-DIM-Z5 + SR-ZV9001K12-DIM-Z5 + + Initial Configuration file + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/sunricher/srzv9001k8.xml b/openzwave/sunricher/srzv9001k8.xml new file mode 100644 index 00000000..83ec844e --- /dev/null +++ b/openzwave/sunricher/srzv9001k8.xml @@ -0,0 +1,53 @@ + + + http://www.openzwave.com/device-database/0330:a305:0300 + images/sunricher/srzv9001k8.png + https://products.z-wavealliance.org/products/3334 + https://www.sunricher.com/media/resources/manual/SR-ZV9001K8-DIM-G4%20Instruction%20V1.pdf + The remote control is a Z-Wave device that can both control other Z-Wave devices and activate scenes in Gateways. + Wall Controller + CEPT (Europe) + SR-ZV9001K8-DIM-G4 + Step 1. Make sure the remote control does not belong to any Z-Wave network, short press any button, if LED +indicator does not turn on, the remote control does not belong to any network, then continue step 2,if LED +indicator turns on, it means the remote control has already been included to a network, please first set the +remote control to exclusion mode (refer to the part "Exclusion" of this manual),then continue step 2. +Step 2. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on +how to turn your controller into inclusion). +Step 3. Press and hold down both buttons and of Group 2 over 3 seconds, LED indicator turns on, the +remote control will be set to inclusion mode, and waiting to be included, after 10s LED indicator blinks 6 times +quickly to indicate successful inclusion. The remote control is a sleepy device, after inclusion it will not enter +into sleepy mode immediately, and will continue activation status for 30s and wait data interaction from the +gateway, the LED indicator will stay solid on, please be patient to wait LED indicator to turn off. + There are two exclusion methods: +Method 1: Exclusion from the primary controller/gateway as follows: +1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on +how to set your controller into exclusion). +2. Press and hold down both buttons and of Group 2 over 3 seconds, LED indicator turns on, the remote +control will be set to exclusion mode, and waiting to be excluded, after 7s LED indicator blinks 4 times quickly to +indicate successful exclusion. +Method 2: Factory reset the remote control will force the remote control to be excluded from a network. (please +refer to the part “Factory Reset” of this manual) +Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary +controller/gateway is missing or otherwise inoperable. + Press and hold down both buttons and of Group 2 for over 10 seconds, LED indicator turns on and then blinks 4 times quickly to indicate successful factory reset. + + Initial Configuration file + + + + + + + + + + + + + + + diff --git a/openzwave/sunricher/srzv9001t4dimeu.xml b/openzwave/sunricher/srzv9001t4dimeu.xml new file mode 100644 index 00000000..37c13e8b --- /dev/null +++ b/openzwave/sunricher/srzv9001t4dimeu.xml @@ -0,0 +1,63 @@ + + + http://www.openzwave.com/device-database/0330:a10d:0003 + images/sunricher/srzv9001t4dimeu.png + https://products.z-wavealliance.org/products/2704/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2704/Z-Wave Wall Controller SR-ZV9001T4-DIM-EU User Manual.pdf + The Wall controller is a Security Enabled Z-Wave Plus device that can both control other Z-Wave devices and activate scenes in Gateways. The wall controller can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. + Wall Controller + CEPT (Europe) + SR-ZV9001T4-DIM-EU + There are two exclusion methods: +Method 1: Exclusion from the primary controller/gateway as follows: +1. Set the primary controller/gateway into exclusion mode (Please refer to your primary +controllers manual on how to set your controller into exclusion). +2. Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” +button for over 3 seconds, the wall controller will be set to exclusion mode, and waiting +to be excluded, then LED indicator turns on and shows 3 short blinks and 1 long blink to +indicate successful exclusion. +Once the wall controller quits “exclusion mode”, the LED indicator will turns off. There +are 3 methods for the wall controller to quit “exclusion mode”: +1. Automatically quits after successful exclusion. +2. Quits after 25 seconds timeout. +3. Press and hold down “ALL ON/OFF” button for over 3 seconds, or short press the +“inclusion/exclusion” button to quit. +Method 2: Factory reset the wall controller will force the wall controller to be excluded +from a network. (please refer to the part “Factory Reset” of this manual) + Press and hold down “inclusion/exclusion” button for over 8 seconds, LED indicator turns on and shows 3 short blinks and 1 long blink to indicate successful factory reset, release “inclusion/exclusion” button, the wall controller will restart automatically. + +If this controller is the primary controller for your network, resetting it will result in the nodes in your network being orphaned and it will be necessary after the reset to exclude and re-include all of the nodes in the network. If this controller is being used as a secondary controller in the network, use this procedure to reset this controller only in the event that the network primary controller is missing or otherwise inoperable. + 1. Set primary controller/gateway into inclusion mode (Please refer to your primary +controllers manual on how to turn your controller into inclusion). +2. Make sure the wall controller does not belong to any Z-Wave network (please refer to +the part “How to check whether the wall controller included to a network” of this manual). +3. Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” +button for over 3 seconds, the wall controller will be set to inclusion mode, and waiting to +be included, then LED indicator turns on and blinks 6 times quickly to indicate +successful inclusion. +Once the wall controller quits “inclusion mode”, the LED indicator will turns off. There +are 3 methods for the wall controller to quit “inclusion mode”: +1. Automatically quits after successful inclusion. +2. Quits after 25 seconds timeout. +3. Press and hold down “ALL ON/OFF” button for over 3 seconds, or short press the +“inclusion/exclusion” button to quit. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2704/xml + + + + + + + + + + + + + + + diff --git a/openzwave/sunricher/srzv9001tccteu.xml b/openzwave/sunricher/srzv9001tccteu.xml new file mode 100644 index 00000000..7b003a27 --- /dev/null +++ b/openzwave/sunricher/srzv9001tccteu.xml @@ -0,0 +1,43 @@ + + + Z-Wave CCT Wall Controller + The Wall controller is a Security Enabled Z-Wave Plus device that can both control another Z-Wave device. + http://www.openzwave.com/device-database/0330:0300:a104 + https://www.sunricher.com/touch-panel-dual-color-z-wave-secondary-controller-sr-zv9001t-cct.html#product_tabs_description_tabbed + http://www.sunricher.com/ + images/sunricher/srzv9001tccteu.png + https://www.sunricher.com/media/resources/manual/SR-ZV9001T-CCT-EU%20Instruction.pdf + Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” button for over 3 seconds, the wall controller will be set to inclusion mode, and waiting to be included, then LED indicator turns on and blinks 6 times quickly to indicate successful inclusion. + Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” button for over 3 seconds, the wall controller will be set to exclusion mode, and waiting to be excluded, then LED indicator turns on and shows 3 short blinks and 1 long blink to indicate successful exclusion. + Press and hold down “inclusion/exclusion” button for over 8 seconds, LED indicator blinks slowly to indicate successful factory reset, release “inclusion/exclusion” button,the wall controller will restart automatically. + + CEPT (Europe) + SR-ZV9001T-CCT-EU + + Initial entry based on manufacturer data and test device + + + + + + Choose working mode of the remote control. + + + + + + + + + false + + + + + + + + + + diff --git a/openzwave/sunricher/srzv9003t4rgbweu.xml b/openzwave/sunricher/srzv9003t4rgbweu.xml new file mode 100644 index 00000000..9448957c --- /dev/null +++ b/openzwave/sunricher/srzv9003t4rgbweu.xml @@ -0,0 +1,38 @@ + + + Z-Wave Wall Controller + The Wall controller is a Security Enabled Z-Wave Plus device that can both control other Z-Wave devices and activate scenes in Gateways. + http://www.openzwave.com/device-database/0330:0300:a108 + http://www.sunricher.com/touch-panel-rgbw-z-wave-wall-controller-sr-zv9001t4-rgbw-eu.html + http://www.sunricher.com/ + images/sunricher/srzv9003t4rgbweu.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/2945/Z-Wave%20Wall%20Controller%20SR-ZV9003T4-RGBW-EU.pdf + Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” button for over 3 seconds, the wall controller will be set to inclusion mode, and waiting to be included, then LED indicator turns on and blinks 6 times quickly to indicate successful inclusion. + Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” button for over 3 seconds, the wall controller will be set to exclusion mode, and waiting to be excluded, then LED indicator turns on and shows 3 short blinks and 1 long blink to indicate successful exclusion. + Press and hold down “inclusion/exclusion” button for over 8 seconds, LED indicator blinks slowly to indicate successful factory reset, release “inclusion/exclusion” button,the wall controller will restart automatically. + https://products.z-wavealliance.org/products/2945 + CEPT (Europe) + SR-ZV9003T4-RGBW-EU + + Initial entry based on manufacturer data and test device + + + + + + + false + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/sunricher/srzv9101sachpeu.xml b/openzwave/sunricher/srzv9101sachpeu.xml new file mode 100644 index 00000000..2d3056c0 --- /dev/null +++ b/openzwave/sunricher/srzv9101sachpeu.xml @@ -0,0 +1,178 @@ + + + http://www.openzwave.com/device-database/0330:D00C:0200 + images/sunricher/srzv9101sachpeu.png + https://products.z-wavealliance.org/products/3331/ + Press and hold down the action button for over 10 seconds, the dimmer will be reset to factory defaults. + +Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable. + The micro smart dimmer is a Z-Wave device designed to work with various types of light sources. It may be +connected to two-wire or three-wire configuration so it can operate with or without neutral lead. The +dimmer can switch or dim connected light source either through Z-Wave devices or through the wall +switch connected directly to it. The smart dimmer is equipped with an algorithm of smart light source +detection which makes configuration easier and ensures high compatibility of the device. It may be used +as a switch with non-dimmable light sources (in 3-wire connection). + Micro Smart Dimmer + 1. Set primary controller/gateway into inclusion mode (Please refer to your primary controller’s manual on how to turn your controller into inclusion). +2. Power on the in-wall dimmer and set it into inclusion mode. There are two methods to set the in-wall dimmer into inclusion mode: +1)Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included. +2)Triple press the action button on the dimmer, it will set the dimmer into inclusion mode. +The connected light will stay solid on for 3 seconds to indicate successful inclusion. + There are two exclusion methods: +Method 1: Exclusion from the primary controller/gateway as follows: +1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion). +2. Triple press the action button, the dimmer will be set to exclusion mode, and waiting to be excluded, then the dimmer will be excluded from the network. +Method 2: Factory reset the dimmer will force it to be excluded from a network. (please refer to the part “Factory Reset” of this manual) +Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3331/SR-ZV9040A-A Micro Smart Dimmer.pdf + SR-ZV9040A-A + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3331/xml + + + + + + + + + Saving state before power failure. + Default Not saved. + + + + + + + Enable/disable to send the basic report to the Lifeline when the load state changed. + When value set as 1, re-power on the dimmer, it will send Basic report automatically. + Default Enabled. + + + + + + Fade time (units between 1-127 represent 1-127 seconds. + Units Betwen 128-244 represent minutes, 128 = 1 minute, 129 = 2 minutes. + This value has the same function as Duration of Multilevel). + Default 1. + + + + Setting minimum brightness value. + Valid value: 0 - 50, the bigger the value is, the higher the loads minimum brightness is. + Note: when configure this value, the value of Multilevel will be configured as 1 automatically so that users can preview the corresponding effect of minimum brightness value + + + + Setting maximum brightness value. + Valid value: 0 - 100, the bigger the value is, the higher the load maximum brightness is. + + + + + Choose MOSFET driving type". + Default trailing edge. + + + + + + + Choose external switch type. + Default normal on/off switch. + + + + + + + Enable/disable external switch to be added to and removed from a network. + When enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a net-work. + Default Enabled. + + + + + + + Enable/disable to detect load after re-power on (detect load type, minimum brightness, maximum brightness) + + + + + + + + Wiring type + + + + + + + + Load type + + + + + + + + + Enable/disable over current protection (over 1.5A for 20 seconds continuously) + + + + + + + Power automatic report absolute threshold, unit is W. + When power changes above the absolute threshold, immediately report current power value + + + + + Power automatic report percentage threshold, unit is %. + When power changes above the percentage threshold, immediately report current power value + + + + + Power metering automatic report time cycle, unit is second. + Valid time cycle value: 5-2678400, when set as 0 report function is disabled + + + + + Energy metering automatic report time cycle, unit is second. + Valid time cycle value: 5-2678400, when set as 0 report function is disabled + + + + + Voltage metering automatic report time cycle, unit is second. + Valid time cycle value: 5-2678400, when set as 0 report function is disabled + + + + + Current metering automatic report time cycle, unit is second. + Valid time cycle value: 5-2678400, when set as 0 report function is disabled + + + + + + + + + + + + diff --git a/openzwave/sunricher/zv2835rac.xml b/openzwave/sunricher/zv2835rac.xml new file mode 100644 index 00000000..1fed0359 --- /dev/null +++ b/openzwave/sunricher/zv2835rac.xml @@ -0,0 +1,161 @@ + + + http://www.openzwave.com/device-database/0330:D017:0200 + CEPT (Europe) + 1. Set primary controller/gateway into inclusion mode (Please refer to your primary controller’s manual on how to turn your controller into inclusion) + +2. Power on the knob dimmer and set it into inclusion mode. There are two methods to set the dimmer into inclusion mode: + +1) Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included. +2) Triple press reset button on the dimmer, it will set the dimmer into inclusion mode + Knob Smart Dimmer + ZV2835RAC + Press and hold down the action button for over 10 seconds, the dimmer will be reset to factory defaults. + There are two exclusion methods: +Method 1: Exclusion from the primary controller/gateway as follows: +1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion). +2. Triple press reset button, the dimmer will be set to exclusion mode, and waiting to be excluded, then the dimmer will be excluded from the network. + +Method 2: Factory reset the dimmer will force it to be excluded from a network. (please refer to the part “Factory Reset” of this manual) + +Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable. + The knob smart dimmer is a Z-Wave device designed to work with various types of light sources. It may be connected to two-wire or three-wire configuration so it can operate with or without neutral lead. The dimmer can switch or dim connected light source either through Z-Wave devices or through the rotary knob directly. The smart dimmer is equipped with an algorithm of smart light source detection which makes configuration easier and ensures high compatibility of the device. It may be used as a switch with non-dimmable light sources (in 3-wire connection). + images/sunricher/zv2835rac.png + + Inital support based on the products manual. + + + + + + + + Saving state before power failure. Default is saved. + + + + + + + Enable/disable to send the basic report to the Lifeline when the load state changed. + When value set as 1, re-power on the dimmer, it will send Basic report automatically. + Default Enabled. + + + + + + Fade time in seconds. 0 is instantly, default is 1. + + + Setting minimum brightness value. + Valid value: 0 - 50, the bigger the value is, the higher the loads minimum brightness is. + + + + Setting maximum brightness value. + Valid value: 0 - 100. + + + + Choose MOSFET driving type. Default trailing edge. + + + + + + Corresponding dimming stepping level for each rotation of the knob (a full dimming stepping level is 99),Valid value: 1-50. + + + + Added to and removed from a network through external switch (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network) + + + + + + + Enable/disable to detect load after re-power on (detect load type, minimum brightness, maximum brightness) + + Note: When the device does not belong to any network, load detection will be enabled every time after re-power on. When the device has already been added to a network, load detection will be disabled + + + + + + + Wiring type + + + + + + + + Load type + + + + + + + + + Enable/disable over current protection (over 3.2A for 20 seconds continuously). + + + + + + + + Power automatic report absolute threshold, unit is WWhen power changes above the absolute threshold, immediately report current power value + + + + + +Power automatic report percentage threshold, unit is %. When power changes above the percentage threshold, immediately report current power value. + + + + + Power metering automatic report time cycle, unit is second. Valid time cycle value: 5~2678400. Default is 600 (10 minutes). + + + + + Energy metering automatic report time cycle, unit is second. Valid time cycle value: 5~2678400. Default is 1800 (30 minutes). + + + + + Voltage metering automatic report time cycle, unit is second. Valid time cycle value: 5~2678400. Default is 3600 (60 minutes). + + + + + Current metering automatic report time cycle, unit is second. Valid time cycle value: 5~2678400. Default is 3600 (60 minutes). + + + + + Setting dimming curve. + + + + + + + Setting startup brightness of the loadValid value: 0~99Note: every time when turn on the load from OFF status, if the target brightness is lower than the startup brightness, the brightness will first go to the startup brightness value then fall down to the target brightness. + + + + + + + + + + + diff --git a/openzwave/sunricher/zv9101.xml b/openzwave/sunricher/zv9101.xml new file mode 100644 index 00000000..d8cefc50 --- /dev/null +++ b/openzwave/sunricher/zv9101.xml @@ -0,0 +1,88 @@ + + + http://www.openzwave.com/device-database/0330:D005:0200 + images/sunricher/zv9101.png + https://products.z-wavealliance.org/products/2918/ + CEPT (Europe) + 1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion). +2. Power on the in-wall dimmer and set it into inclusion mode. There are two methods to set the in-wall dimmer into inclusion mode: +1)Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included. +2)Triple press the action button on the dimmer, it will set the plug into inclusion mode. +The connected light will stay solid on for 3 seconds to indicate successful inclusion. + In-wall Dimmer + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2918/Z-Wave In-wall Dimmer SR-ZV9101SAC-HP-EU.pdf + SR-ZV9101SAC-HP-EU + Press and hold down the action button for over 10 seconds, the dimmer will be reset to factory defaults. + There are two exclusion methods: +Method 1: Exclusion from the primary controller/gateway as follows: +1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion). +2. Triple press the action button, the dimmer will be set to exclusion mode, and waiting to be excluded, then the dimmer will be included to the network. +Method 2: Factory reset the dimmer will force the it to be excluded from a network. +(please refer to the part “Factory Reset” of this manual) +Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable. + The in-wall dimmer is a Z-Wave device that is used to switch ON/OFF and adjust light intensity of the connected light and can be controlled by other Z-Wave devices. The Inwall Dimmer can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non- battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2918/xml + + + + + + + + + Saving state before power failure. Default Not saved. + + + + + + + Enable/disable to send the basic report to the Lifeline when the load state changed. + When value set as 1, re-power on the dimmer, it will send Basic report automatically. + Default Enabled. + + + + + + Fade time (units between 1-127 represent 1-127 seconds. + Units Between 128-244 represent minutes, 128 = 1 minute, 129 = 2 minutes. + This value has the same function as Duration of Multilevel). + Default 1. + + + + Setting minimum brightness value. + Valid value: 0 - 50, the bigger the value is, the higher the loads minimum brightness is. + Note: when configure this value, the value of Multilevel will be configured as 1 automatically so that users can preview the corresponding effect of minimum brightness value + + + + + Choose MOSFET driving type". Default trailing edge. + + + + + + Enable/disable external switch to be added to and removed from a network. + When enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a net-work. + Default Enabled. + + + + + + + + + + + + + + diff --git a/openzwave/sunricher/zv9101fa.xml b/openzwave/sunricher/zv9101fa.xml new file mode 100644 index 00000000..3fba18c3 --- /dev/null +++ b/openzwave/sunricher/zv9101fa.xml @@ -0,0 +1,96 @@ + + + http://www.openzwave.com/device-database/0330:D002:0200 + images/sunricher/srzv9101facct.png + CEPT (Europe) + U.S. / Canada / Mexico + Australia / New Zealand + Russia + 1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion). +2. Power on the in-wall dimmer and set it into inclusion mode. There are two methods to set the in-wall dimmer into inclusion mode: +1)Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included. +2)Triple press the action button on the dimmer, it will set the plug into inclusion mode. +The connected light will stay solid on for 3 seconds to indicate successful inclusion. + Dimmable LED controller + https://www.sunricher.com/media/resources/manual/SR-ZV9101FA-CCT%20Instruction%20V1.pdf + SR-ZV9101FA + Press and hold down the action button for over 10 seconds, the dimmer will be reset to factory defaults. + There are two exclusion methods: +Method 1: Exclusion from the primary controller/gateway as follows: +1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion). +2. Triple press the action button, the dimmer will be set to exclusion mode, and waiting to be excluded, then the dimmer will be included to the network. +Method 2: Factory reset the dimmer will force the it to be excluded from a network. +(please refer to the part “Factory Reset” of this manual) +Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable. + The LED dimmer is a Z-Wave device that is used to switch ON/OFF, adjust light intensity and optionally the color temperature and rgbw of the connected tunable LED light and can be controlled by other Z-Wave devices. + + Initial import, adapted from ZV9101 + + + + + + + + + Saving state before power failure. Default Not saved. + + + + + + + Enable/disable to send the basic report to the Lifeline when the load state changed. + When value set as 1, re-power on the dimmer, it will send Basic report automatically. + Default Enabled. + + + + + + Choose a cool light stage mode (when receiving Command Class Switch Color, it recovers to normal lighting mode.) + + + + + + + + + + + + + Speed of stage mode. 0 is the slowest, 255 is the fastest + + + + + Execution times of stage mode. + 0: unlimited times. + 1~255: execution times 1~255 + + + + + The hue of stage mode. The hue is only valid for fade in and fade out mode, flash mode + + + + + Enable/disable external switch to be added to and removed from a network (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network) + + + + + + + + + + + + diff --git a/openzwave/swiid/swiidinter.xml b/openzwave/swiid/swiidinter.xml new file mode 100644 index 00000000..9a9fa281 --- /dev/null +++ b/openzwave/swiid/swiidinter.xml @@ -0,0 +1,32 @@ + + + http://www.openzwave.com/device-database/0166:0100:0100 + images/swiid/swiidinter.png + https://products.z-wavealliance.org/products/1082/ + CBCC SwiidInter - Z-Wave Cord Switch + SW-ZCS-1 + CEPT (Europe) + Z-Wave cord switch + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1082/xml + + + + + + + Enable/Disable ALL ON/OFF + + + + + + + + + + + + + + diff --git a/openzwave/swiid/swiidplug.xml b/openzwave/swiid/swiidplug.xml new file mode 100644 index 00000000..1990461e --- /dev/null +++ b/openzwave/swiid/swiidplug.xml @@ -0,0 +1,19 @@ + + + + + + + Enable/Disable ALL ON/OFF + + + + + + + + + + + + diff --git a/openzwave/technisat/03009496.xml b/openzwave/technisat/03009496.xml new file mode 100644 index 00000000..f8f11727 --- /dev/null +++ b/openzwave/technisat/03009496.xml @@ -0,0 +1,70 @@ + + + http://www.openzwave.com/device-database/0299:1A93:0005 + images/technisat/03009496.png + https://products.z-wavealliance.org/products/3778/ + TechniSat Shutter is powered with mains voltage so it is always awake. + Use this procedure only when the network primary controller is missing or otherwise inoperable. 1. When the roller shutter is in the lowermost position, press and hold T2 for more than 20 seconds. 2. The LED will alternately flash red and green for 5 seconds after a successful reset. + 0300/9496 + Shutter + 1. Install the TechniSat Shutter. + 2. After checking the correct installation, re-enable electrical power at the main fuse or circuit breaker. + 3. Start the Z-Wave device add mode on your Z-Wave gateway, according to the gateway‘s manual. + 4. Press T1 3x within 1 second. + 5. The red status LED is on while the device is added to the Z-Wave network. + 6. The green LED is on for 5 seconds after successfully adding the device. + + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3778/Manual_SMD01_Shutter.pdf + CEPT (Europe) + 1. Start the Z-Wave device remove mode on your Z-Wave gateway, according to the gateway‘s manual. + 2. When the roller shutter is in the uppermost position, press and hold T1 for more than 10 seconds. + 3. The red status LED is on while the device is removed from the Z-Wave network. + 4. The green LED is on for 5 seconds after successfully removing the device. + + Designed as a drop-in replacement for your shutter wall switch from leading brand manufacturers, TechniSat's Shutter-Switch integrates your wall switch into the Smart Home future. Featuring Z-Wave SmartStart and S2 security for easy installation and secure operation, your shutter switch can now be controlled from your Smart Home as well. + - Full manual operation + - can trigger central scenes via multiple button clicks + - Short circuit and overload protection monitoring + + + Initial file based on z-wavealliance.org + + + + + + + Enable/disable central scene notifications for 2x-5x button presses. + + + + + + + 3 to 8640 - Interval of current wattage meter reports in 10 seconds increments. + 0 - Disable unsolicited meter reports of current wattage. + + + + + Interval of active energy meter reports in minutes. + - 10 to 30240 - Interval of active energy meter unsolicited reports in minutes (10 minutes - 3 weeks) + - 0 - Disable unsolicited meter reports of active energy. + + + + + Setting this parameter to 1 will start a manual shutter calibration. + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/technisat/03009497.xml b/openzwave/technisat/03009497.xml new file mode 100644 index 00000000..b0249930 --- /dev/null +++ b/openzwave/technisat/03009497.xml @@ -0,0 +1,104 @@ + + + + images/technisat/03009497.png + https://products.z-wavealliance.org/products/3798/ + TechniSat Dimmer-Switch is powered with mains voltage so it is always awake. + Use this procedure only when the network primary controller is missing or otherwise inoperable. + 1. Press and hold position T2 for more than 20 seconds. + 2. The LED will alternately flash red and green for 5 seconds after a successful reset. + + 0300/9497 + Dimmer + 1. Install the TechniSat Dimmer. + 2. After checking the correct installation, re-enable electrical power at the main fuse or circuit breaker. + 3. Start the Z-Wave device add mode on your Z-Wave gateway, according to the gateway‘s manual. + 4. Press T1 3x within 1 second. + 5. The red status LED is on while the device is added to the Z-Wave network. + 6. The green LED is on for 5 seconds after successfully adding the device. + + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3798/Manual_SMD01_Dimmer.pdf + CEPT (Europe) + 1. Start the Z-Wave device remove mode on your Z-Wave gateway, according to the gateway‘s manual. + 2. Press and hold position T1 for more than 10 seconds. + 3. The red status LED is on while the device is removed from the Z-Wave network. + 4. The green LED is on for 5 seconds after successfully removing the device. + + Designed as a drop-in replacement for your single wall switch or dimmer from leading brand manufacturers, TechniSat's Dimmer integrates your wall switch into the Smart Home future. + Featuring Z-Wave SmartStart and S2 security for easy installation and secure operation, yourdimmer can now be controlled from your Smart Home as well. + ● Full manual operation + ● can trigger central scenes via multiple button clicks + ● Integrated 230 V auxiliary input for push button or toggle switch types, applicable in alternating switching and or intermediate switching circuits + ● Short circuit and overload protection monitoring + + + Initial file based on the work of Mathis Klooss for the Single-Switch and z-wavealliance.org information+local handbook + + + + + + + Enable/disable central scene notifications for 2x-5x button presses. + + + + + + + 3 to 8640 - Interval of unsolicited reports in 10s increments, a value of 3 means 30 seconds (30 seconds - 1 day) + 0 - Disable unsolicited meter reports of current wattage. + + + + + Interval of active energy meter reports in minutes. + - 10 to 30240 - Interval of active energy meter unsolicited reports in minutes (10 minutes - 3 weeks) + - 0 - Disable unsolicited meter reports of active energy. + + + + + Operations mode for push buttons controlling the output. + - Normal Switch: In this mode the top button will turn the output on, while the bottom button will turn the output off. + - Toogle Switch: In this mode any button press will toggle the output - when on it will be turned off, when off it will be turned on. + + + + + + + Configuration of switch type connected to extension input S. + - External Normal Switch: Use this value if a toggle switch is connected to extension input S. + - External Push Button: Use this value if a push button switch is connected to extension input S. + + + + + + + Central Scene mapping of extension input S. + - Central Scene 1: Multiple button presses (2x-5x) on extension input S will trigger events of central scene 1. + - Central Scene 2: Multiple button presses (2x-5x) on extension input S will trigger events of central scene 2. + - Central Scene 3: Multiple button presses (2x-5x) on extension input S will trigger events of central scene 3 - an additional central scene exclusive to extension input S. + + + + + + + + Select the dimming curve that should be used. + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/technisat/03009499.xml b/openzwave/technisat/03009499.xml new file mode 100644 index 00000000..581bcf20 --- /dev/null +++ b/openzwave/technisat/03009499.xml @@ -0,0 +1,96 @@ + + + http://www.openzwave.com/device-database/0299:1A90:0002 + images/technisat/03009499.png + https://products.z-wavealliance.org/products/3677/ + TechniSat Single-Switch is powered with mains voltage so it is always awake. + Use this procedure only when the network primary controller is missing or otherwise inoperable. + 1. Press and hold position T2 for more than 20 seconds. + 2. The LED will alternately flash red and green for 5 seconds after a successful reset. + + 0300/9496 + Shutter + 1. Install the TechniSat Single-Switch. + 2. After checking the correct installation, re-enable electrical power at the main fuse or circuit breaker. + 3. Start the Z-Wave device add mode on your Z-Wave gateway, according to the gateway‘s manual. + 4. Press position T1 3x within 1 second. + 5. The red status LED is on while the device is added to the Z-Wave network. + 6. The green LED is on for 5 seconds after successfully adding the device. + + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3778/Manual_SMD01_Shutter.pdf + CEPT (Europe) + 1. Start the Z-Wave device remove mode on your Z-Wave gateway, according to the gateway‘s manual. + 2. Press and hold position T1 for more than 10 seconds. + 3. The red status LED is on while the device is removed from the Z-Wave network. + 4. The green LED is on for 5 seconds after successfully removing the device. + + Designed as a drop-in replacement for your single wall switch from leading brand manufacturers, TechniSat's Single-Switch integrates your wall switch into the Smart Home future. Featuring Z-Wave SmartStart and S2 security for easy installation and secure operation, your wall switch can now be controlled from your Smart Home as well. + - Full manual operation + - can trigger central scenes via multiple button clicks + - Integrated 230 V auxiliary input for push buttons or toggle switch types, applicable in alternating switching and or intermediate switching circuits + - Short circuit and overload protection monitoring + + + Initial file based on z-wavealliance.org + + + + + + + Enable/disable central scene notifications for 2x-5x button presses. + + + + + + + 3 to 8640 - Interval of unsolicited reports in 10s increments (30 seconds - 1 day) + 0 - Disable unsolicited meter reports of current wattage. + + + + + Interval of active energy meter reports in minutes. + - 10 to 30240 - Interval of active energy meter unsolicited reports in minutes (10 minutes - 3 weeks) + - 0 - Disable unsolicited meter reports of active energy. + + + + + Operations mode for push buttons controlling the output. + - Normal Switch: In this mode the top button will turn the output on, while the bottom button will turn the output off. + - Toogle Switch: In this mode any button press will toggle the output - when on it will be turned off, when off it will be turned on. + + + + + + + Configuration of switch type connected to extension input S. + - Normal Switch: Use this value if a toggle switch is connected to extension input S. + - Toogle Switch: Use this value if a push button switch is connected to extension input S. + + + + + + + Central Scene mapping of extension input S. + - Central Scene 1: Multiple button presses (2x-5x) on extension input S will trigger events of central scene 1. + - Central Scene 2: Multiple button presses (2x-5x) on extension input S will trigger events of central scene 2. + - Central Scene 3: Multiple button presses (2x-5x) on extension input S will trigger events of central scene 3 - an additional central scene exclusive to extension input S. + + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/telldus/tzdw100.xml b/openzwave/telldus/tzdw100.xml new file mode 100644 index 00000000..5e1e59ab --- /dev/null +++ b/openzwave/telldus/tzdw100.xml @@ -0,0 +1,78 @@ + + + http://www.openzwave.com/device-database/0176:0001:0005 + images/telldus/tzdw100.png + https://products.z-wavealliance.org/products/1455/ + Start the exclusion mode on the Z-Wave controller. Press the button on the device three times fast. The device will now be removed from the Z-Wave-network. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1455/Quickguide_Sensor_Switch_107x153mm_PMS.pdf + Automatically add device to network +When a battery is inserted, the device is in automatical add mode for one minute (Network Wide Inclusion, NWI). This means that the device is added automatically when the Z-Wave controller enters add mode. + +Manual add device to network +Start the add mode on the Z-Wave controller. Press the button on the device three times fast. The device will now be added into the Z-Wave-network. + Press the button on the sensor one time short to wake up the device. + Door/window sensor + Press and hold the button until the LED starts flashing (approx. 6 seconds). +Press the button once more, short. +The device will now reset to factory defaults. The LED will now flash, indicating that it’s no longer added in any Z-Wave network. + +Please note! Only use the reset procedure when the primary controller is missing or inoperable. + CEPT (Europe) + TZDW-100 + This magnet sensor contains the latest Z-Wave technology with the ability to remotely control other Z-Wave units available in your network. The fact that it is battery operated and so small you can virtually place it anywhere you want – on doors, windows or drawers, without the need of wiring. Screw or tape up the holder and then click the sensor in place. Done! The sensor is designed to be seen as little as possible and we have made it significantly smaller than other sensors. It consists of two parts that will merge into a stylish unit when the sensor is closed. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1455/xml + + + + + + Type of input no. 2, what the input 1 will report if no contact is made + + + + + + + Possible parameter settings: (1 - 63) and 255. When setting 255 will automatically be set dimmer to the previous condition i.e 30% or what the last state was. + + + Type of commands to association group 2 + + + + + Type of input no. 3, what the input 3 will report if no contact is made + + + + + + + Possible parameter settings: (1 - 63) and 255. When setting 255 will automatically be set dimmer to the previous condition i.e 30% or what the last state was. + + + Type of commands to association group 3 + + + + + Status change signalled by LED. Default setting: LED turned On + + + + + Select the type of command to be sent in the Lifeline + + + + + + + + + + + + + diff --git a/openzwave/telldus/tzwp100.xml b/openzwave/telldus/tzwp100.xml new file mode 100644 index 00000000..6910010f --- /dev/null +++ b/openzwave/telldus/tzwp100.xml @@ -0,0 +1,51 @@ + + + http://www.openzwave.com/device-database/0176:0001:0003 + images/telldus/tzwp100.png + https://products.z-wavealliance.org/products/1536/ + Tripple click the button on the device + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1536/manual.pdf + The slim design makes this plugin switch fit almost everywhere. You can even have two switches connected into a standard 2-way wall outlet at the same time. It has a repeater function for the Z-Wave network so you can extend the range of your smart home system. Easy to install and to include in the powerful Telldus Live! system. Control lights and other electronic devices up to 2300 W (resistive load). Option to turn off indication LED. 500 chip, Z-Wave Plus. + Plug-in Switch (Schuko) + CEPT (Europe) + Tripple click the button on the device + TZWP-100 + Press and hold the button until the LED starts flashing white (approx. 6 seconds). +Press the button once more, short. + +Please note! Only use the reset procedure when the primary controller is missing or inoperable. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1536/xml + + + + + + + + Number of minutes before it shutdown automatically (0 = disabled). + + + + + Define how the plug will react after the power supply is back on. + + + + + + + + Set the intensity of the LED indicator (0-100). + + + + + + + + + + + diff --git a/openzwave/telldus/tzwp102.xml b/openzwave/telldus/tzwp102.xml new file mode 100644 index 00000000..c96abd00 --- /dev/null +++ b/openzwave/telldus/tzwp102.xml @@ -0,0 +1,106 @@ + + + http://www.openzwave.com/device-database/0176:0003:0003 + images/telldus/tzwp102.png + https://products.z-wavealliance.org/products/2892/ + TZWP-102 + CEPT (Europe) + Plug-in Switch Mini + 1. Set the Z-Wave network main controller into removing mode. +2. Short press Z-button twice. +3. The LED keep blink to the end of remove exclusion, If the remove for exclusion is successful, The LED will keep slow flash, Otherwise, LED will be in power indication mode. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2892/TZWP-102_technical-manual.pdf + Reset Smart Plug to factory Default: +1. Make sure that the Smart Plug has been connected to the power supply. +2. Press and hold the Z-button for 5 seconds. +3. If holding time is more than one second, the LED will blink faster and faster. If holding time is more than 5 seconds, the LED will be solid for 3 seconds to indicate that the resetting is successful. Otherwise, repeat step 2. + + Use this procedure only in the event that the network primary controller missing or otherwise inoperable. + 1. Set the Z-Wave network main controller into learning mode. +2. Short press the Z-button twice +3. The LED keep blink to the end of add inclusion, If the add for inclusion is successful, LED will turn on within 2 seconds and Then will be in power indication mode, Otherwise, The LED will keep slow flash. + + Smart Plug can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. +Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade. + + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2892/xml + + + + + + + + If the current exceeds 16A for more than 5 sec, the load will be switched off. Default 1. + + + + + + + Define how the plug will react after the power supply is back on. Default 0. + + + + + + + + Smart Plug can send notifications to associated devices in Lifeline when the status of the plug is changed. Default 1. + + + + + + + + Configure LED mode. Default 0. + + + + + + + This parameter will send a power report automatically if the power value changes of x W (Watts) compared to the last report. Default 50. + + + + + This parameter will send a power report automatically if the power value changes of x % compared to the last report. Default 10. + + + + + This parameter defines the period of sending power reports. Default 600. + 0=Disabled, 5-2678400 seconds + + + + + This parameter defines the period of sending energy reports. Default 3600. + 0=Disabled, 5-2678400 seconds + + + + + This parameter defines the period of sending voltage reports. Default 0. + 0=Disabled, 5-2678400 seconds + + + + + This parameter defines the period of sending current reports. Default 0. + 0=Disabled, 5-2678400 seconds + + + + + + + + + + diff --git a/openzwave/there/800z.xml b/openzwave/there/800z.xml new file mode 100644 index 00000000..ed609913 --- /dev/null +++ b/openzwave/there/800z.xml @@ -0,0 +1,22 @@ + + + http://www.openzwave.com/device-database/010c:0001:0001 + images/there/800z.png + https://products.z-wavealliance.org/products/758/ + CEPT (Europe) + http://therecorporation.com/en/platform + ThereGate Gateway Controller + ThereGate integrates different systems and equipment used in buildings and homes for remote data acquisition, control and automation. It is a hub that allows for cost efficient connection of many systems and devices to each other, to the network, to back-end systems and to the users with easy, ubiquitous interfaces. ThereGate is a development of the Nokia Home Control Center (HCC). It is a Linux based platform with open interfaces and a software engine (ThereCore™) that enables easy creation of applications and the integration of different devices, technologies and protocols. The base services (ThereWare™), once implemented for one device, are then equally available to any solution built on ThereGate – either by There Corporation or by any party developing applications that run on the gateway. + +Depending on the solution, connectivity may be realized in different ways. Some applications are mainly used locally, but most involve remote connections. The ThereGate concept is designed to work equally well with regular existing internet connections and the optional built in 3G modem, regardless if the user is a service provider’s system or a person browsing with a cellular phone. + +In addition to the power of limitless connectivity and local processing options ThereGate also has a full fledged Web server inside, like any powerful Linux server. This web server is connected to all the services and resources inside the gate allowing for development of local applications and displays. + +The possibility for local applications and displays & user interfaces is important for a number of reasons, one of them being the interactivity and speed. To gather and display real-time information from a number of sources just doesn’t make sense any other way than locally. The amount of data in this kind of applications makes use of back-end systems or web portals too impractical and expensive. The amount and granularity of real-time or near real-time measurement data also brings along the issues of privacy – because it can reveal very much information of the property and the inhabitants. So this kind of information is best safe at home, only in the fingers of the person(s) who own it. Relevant pieces of it can then be made available for external services. + 800Z + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/758/xml + + + + diff --git a/openzwave/thermofloor/heatit-zdim.xml b/openzwave/thermofloor/heatit-zdim.xml new file mode 100644 index 00000000..0857c06a --- /dev/null +++ b/openzwave/thermofloor/heatit-zdim.xml @@ -0,0 +1,173 @@ + + + + http://www.openzwave.com/device-database/019b:2200:0003 + images/thermofloor/heatit_zdim.png + https://products.z-wavealliance.org/products/3261 + Zdim + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3261/Manual_Heatit_Z-DIM_FW%201.0_Ver2019-A_ENG.pdf + Z-Wave rotary dimmer for different light sources. The LED dimmer dims at low load without the light flickering. Dimmer LED from 1-200VA, 230V halogen and incandescent bulbs, dimmable LED drivers and electronic transformers. Not affected by additional starting currents. Need L + N conductor connected. +The dimmer has end-turn function. This allows you to turn on the light and dimming with one dimmer, and then turn off the light with another dimmer. Convenient for example in stairs and corridors. +The dimmer fits into standard Elko, Schneider Exxact and Gira System 55 frame systems. + +FUNCTIONS +- Z-wave rotary dimmer +- Scene controller +- Dims: +- LED +- 230V halogen +- Incandescent lightbulbs +- Dimable LED-drivers +- Electronic transformators +- Starts at 1VA and dims up to 200VA LED +- Trailing edge +- Multiway switching option +- Electronic thermal cutoff with automatic reset +- Firmware updates (OTA) +- Power metering +- Supports encryption mode: S0, S2 Authenticated Class, S2 Unauthenticated Class + +CONNECTION +1. Disconnect the power. +2. Connect the live to the dimmer terminal marked "L". +3. Connect the neutral to the dimmer terminal marked "N". +4. Connect the neutral to the load terminal marked "N". +5. Connect the load terminal marked "L" to the dimmer terminal marked (see wiring + diagram). +6. Install the dimmer (A) in the wall box. Make sure that no wires are pinched. +7. Attach the cover (B) with the supplied nut (C). +8. Attach the button (D) with a simple push. +To use the multiway function (stairway function) a 230VAC rated momentary switch +can be connected as follows: +9. Connect the live to the toggle switch terminal marked "L". +10. Connect the toggle switch terminal marked to the dimmer terminal marked "S" + (see wiring diagram). + +TECHNICAL DATA +Protocol Z-Wave, 868,4MHz +Chip Z-Wave 500 chip +SDK 6.71.03 +Rated voltage 230V AC 50Hz +Power 1VA - 200VA +Input current 0,9A +Controls Push and rotary dimmer +Operating temperature -20°C - 40 °C +Connection Max. 2,5mm2 +Flush mounting depth 15mm +IP Code IP 20 +Size (LxWxH) 84 x 84 x 43mm + +APPROVALS +Z-Wave Plus +CE +EN 55015/A2: 2009, EN 61547:2009 +EN 61000-3-2/A2:2009 +EN 61000-3-3:2008 +EN 60669-2-1/A12:2010 +EN 60669-1:A2:2008 +EMC 2014/30/EU, RoHS 2011/65/EU +LVD 2014/35/EU + + INCLUSION/EXCLUSION +Press the main button on dimmer 6 times in a rapid sequence. Heatit Z-DIM is now included in your Z-Wave network. + CEPT (Europe) + Heatit Zdim + FACTORY RESET - RES +By pressing and holding the main button for 20 seconds, the dimmer will perform +a complete factory reset. The connected light source will blink once and go in the +"OFF" state if successfully reset. NB! Please use this procedure only when the primary +controller is missing or otherwise inoperable + INCLUSION/EXCLUSION +Press the main button on dimmer 6 times in a rapid sequence. Heatit Z-DIM is now included in your Z-Wave network. + + Initial release + + + + + + +The parameter defines the value of connected load. Refer to Paragraph 8 "Power Metering". +0 = Default +1 - 200 = 1-200 Watts connected load + +POWER METERING +The Heatit Z-Dim has functionality to calculate power consumption. To enable this +function, Parameter 1 "Connected load" should have a value greater than 0. This is an +estimated value, therefore power consumption accuracy depends on load estimation. +1. Estimate the load value (Watt) connected to the Heatit Z-Dim. +2. Use this value in Parameter 1. +Heatit Z-Dim can report accumulated (kWh) and instant (Watt), or only instant (Watt) +power consumption. The report time interval can be altered by Parameter 9. + + + + +The parameter defines the lowest dimming level of the dimmer. The value must be lower than parameter 3 "Maximum Dim Level" +1% - 98% Default is 20 (20%) + + + + +The parameter defines the highest dimming level of the dimmer. +The value must be higher than parameter 2 "Minimum Dim Level" +2% - 99% Default is 85 (85%) + + + + +The parameter defines how many steps it should take to dim from minimum +to maximum dim level (One round = 20 steps). +5 - 255 = 5-255 steps. Default is 15 (3/4 round) + + + + The parameter defines the double press functionality. + + + + + Enables scene controller + + + + + +The parameter defines the dimming level when restored from the OFF state +by push button. +0 = Restores last dim level (Default) +1 - 99 = 1% - 99% + + + + +The parameter defines how long it takes to dim to the desired level. +Note! Only Multilevel Switch Command Class is affected by this parameter. +0 = Disabled +1 - 127 = Duration in seconds (1 - 127 seconds. Default is 1) +128 - 255 = Duration in minutes (1 - 127 minutes) + + + + +The parameter defines the report interval for Power Metering. +30 - 32767 = Duration in seconds (30 - 32 767. Default is 60) + + + + +The parameter defines the initial dimming level after power loss. +1 - 99 = 1% - 99% Default is 50 (50%) + + + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/thermofloor/heatit021.xml b/openzwave/thermofloor/heatit021.xml new file mode 100644 index 00000000..8828667a --- /dev/null +++ b/openzwave/thermofloor/heatit021.xml @@ -0,0 +1,162 @@ + + + http://www.openzwave.com/device-database/019B:0001:0001 + images/thermofloor/heatit021.png + https://products.z-wavealliance.org/products/1234/ + Heatit Z-Wave is an electronic thermostat for mounting in a standard wall box. The thermostat has a built-in Z-Wave chip that +can be connected to Home Automation systems like Fibaro, Sensio, Vera, Zipato and others. +The display will show the actual room temperature. By pressing the buttons, the display will show the set value. +Heatit Z-Wave is equipped with a single-pole switch. +The thermostat can handle loads up to 16A/3600Wat 230V. If the load is greater than this, the thermostat needs to be connected to a contactor. It can be used with two external temperature sensors. + +FUNCTIONS +• Room sensor +• Floor sensor +• Temperature limiter +• Power regulator +• Z-Wave chip 500 series +• Week program/setback temperature via gateway +• Setback mode +• 7-segment LCD-screen +• Can be used in connection with diff erent NTC-sensors +• Lock mode/child lock +• Backlight +• Calibration +• 8 scenarios +CONNECTION CLAMPS +Use 1,5 mm² or 2,5 mm² cables according to power need. +TECHNICAL DATA +Rated voltage: 230V 50/60Hz +Max. load: 3600W +Max. current: 16A +Power consumption: 1,5W +Protection class: IP21 +Min/Max installation temp: -20°C to 40°C +Min/Max operating temp: 5°C to 40°C +Temperature intervals: Floor sensor 5°C to 40°C +Room sensor 5°C to 40°C +Hysteresis: 0,5°C +Sensor values: 0°C 29,1 kOhm +10°C 18,6 kOhm +15°C 15,1 kOhm +20°C 12,2 kOhm +25°C 10,0 kOhm +Switch: Single-pole + INCLUSION/EXCLUSION +To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. +The display will show OFF. Press Right (down) 4 times till you see Con in the display. +Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately +2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion +fails, Err (error) will appear. +Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1234/Manual_Multireg Z-Wave_Ver2015-A.pdf + CEPT (Europe) + Heatit Z-Wave + TF021 + FACTORY RESET - RES +By pressing buttons Left and Center (up and confirm) for 20 seconds, the thermostat will perform a complete factory reset. +NB! Please use this procedure only when the primary controller is missing or otherwise inoperable. + INCLUSION/EXCLUSION +To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. +The display will show OFF. Press Right (down) 4 times till you see Con in the display. +Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately +2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion +fails, Err (error) will appear. +Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings. + If Er2 appears in the display, touch any button to restart the display. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1182/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1234/xml + + + + + + + + + + + + + + + + + + + + + + + + 0 + true + + + + + + + + + + + + + + + + + + + + + + + + + + + 3-30 (0.3C - 3.0C) + + + 50-400 (5.0C - 40.0C) + + + 50-400 (5.0C - 40.0C) + + + 50-400 (5.0C - 40.0C) + + + 50-400 (5.0C - 40.0C) + + + 0-9. Min temperature in Power Regulator Mode (setting 2. Temperature sensor - P) + + + 50-400 (5.0C - 40.0C) + + + 50-400 (5.0C - 40.0C) + + + 0-10 + + + + Only if cooling is enabled. + 50-400 (5.0C - 40.0C) + + + + + + + + + + + + diff --git a/openzwave/thermofloor/heatit056.xml b/openzwave/thermofloor/heatit056.xml new file mode 100644 index 00000000..bada9b19 --- /dev/null +++ b/openzwave/thermofloor/heatit056.xml @@ -0,0 +1,184 @@ + + + http://www.openzwave.com/device-database/019B:0202:0003 + images/thermofloor/heatit056.png + https://products.z-wavealliance.org/products/3065/ + Adding the device: +To add the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Now start add device in your home automation software. Start adding mode by pressing Center (confirm) button for approximately 2 seconds. The icon will appear in the display. Adding Mode is indicated in the display by some “circling” LED segments in the display until the timeout occurs after 20 seconds or the module has been added in the network. Confirmation will show Inc/EcL in the display. If adding fails, Err (error) will appear. + Z-TRM2fx + Heatit Z-TRM2fx is equipped with a single pole switch and it fits most System 55 frames (Elko RS16, Schneider Exxact, Gira, Jung etc.). The thermostat can withstand a load of max 13A /2900W at 230V. At higher loads the thermostat must control a contactor. The thermostat may be connected to two wired external sensors. +The thermostat has the capacity of up to 8 associations (relays, wall plugs etc.). +The thermostat is designed for electrical heating. +FEATURES +Floor sensor +External room sensor +Temperature limiter +Weekly program/setback via gateway or pilot wire +Multilevel sensor command class +Firmware updates (OTA) +Power metering +LED-diode +Can be used in connection with different NTC-sensors +Lock mode/child lock +Calibration +8 associations +Supports encryption mode: S0, S2 Authenticated Class, S2 Unauthenticated Class + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3065/Manual_Heatit_Z-TRM2fx_ENG_3.1.pdf + Removing the device: +To remove the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Now start remove device in your home automation software. Start removing mode by pressing Center (confirm) button for approximately 2 seconds. The icon will appear in the display. Removing Mode is indicated in the display by some “circling” LED segments in the display until the timeout occurs after 20 seconds or the module has been removed in the network. Confirmation will show Inc/EcL in the display. If removing fails, Err (error) will appear. + CEPT (Europe) + By pressing buttons Right and Center (down and confirm) for 20 seconds, the thermostat will perform a complete factory reset. +NB! Please use this procedure only when the primary controller/ gateway is missing or otherwise inoperable. + Heatit Z-TRM2fx + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3065/xml + + + + + + + + + + + + + + + + + + + + + + 0 + true + + + + + + + + + 0 + true + + + + + Set operation mode + + + + + + + Set sensor mode + + + + + + Floor sensor type (10K NTC Default) + + + + + + + + + 3-30 (0.3C - 3.0C) Default is 5 (0.5C) + + + 50-400 (5.0C - 40.0C) Default is 50 (5.0C) + + + 50-400 (5.0C - 40.0C) Default is 400 (40.0C) + + + 50-400 (5.0C - 40.0C) Default is 50 (5.0C) + + + 50-400 (5.0C - 40.0C) Default is 400 (40.0C) + + + 50 - 400 (5.0C - 40.0C) Default is 210 (21.0C) + + + 50-400 (5.0C - 40.0C) Default is 180 (18.0C) + + + 50-400 (5.0C - 40.0C) Default is 210 (21.0C) + + + -40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. + + + -40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. + + + Show setpoint or calculated temperature on display( + + + + + 0-100 (0 - 100%) + + + 0-100 (0 - 100%) + + + 0-100 (0 - 100%) + + + 0-100 (0 - 100%) + + + + 0 (Report disabled) + 30-32767 (30-32767 seconds) + + + + 0-100 (0.1C - 10.0C) Default is 10 (1.0C) + + + + 0 (Report disabled) + 30-32767 (30-32767 seconds) + + + + 0-127 A delta value of 0 - 12.7 kWh will result in a metering report. Default is 10 (1.0 kWh) + + + + + + + + + + + + + + + + true + + + + + + true + + + diff --git a/openzwave/thermofloor/heatit058.xml b/openzwave/thermofloor/heatit058.xml new file mode 100644 index 00000000..a97cc9ab --- /dev/null +++ b/openzwave/thermofloor/heatit058.xml @@ -0,0 +1,174 @@ + + + + http://www.openzwave.com/device-database/019B:0203:0003 + images/thermofloor/heatit058.png + https://products.z-wavealliance.org/products/3802/ + Adding the device: +To add the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Now start add device in your home automation software. Start adding mode by pressing Center (confirm) button for approximately 2 seconds. The icon will appear in the display. Adding Mode is indicated in the display by some “circling” LED segments in the display until the timeout occurs after 20 seconds or the module has been added in the network. Confirmation will show Inc/EcL in the display. If adding fails, Err (error) will appear. + Z-TRM3 + Heatit Z-TRM3 is equipped with a single pole switch and it fits most System 55 frames (Elko RS16, Schneider Exxact, Gira, Jung etc.). The thermostat can withstand a load of max 13A /2900W at 230V. At higher loads the thermostat must control a contactor. The thermostat may be connected to two wired external sensors. +The thermostat has the capacity of up to 8 associations (relays, wall plugs etc.). +The thermostat is designed for electrical heating. +FEATURES +Floor sensor +External room sensor +Temperature limiter +Weekly program/setback via gateway or pilot wire +Multilevel sensor command class +Firmware updates (OTA) +Power metering +LED-diode +Can be used in connection with different NTC-sensors +Lock mode/child lock +Calibration +8 associations +Supports encryption mode: S0, S2 Authenticated Class, S2 Unauthenticated Class + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3802/Manual_Heatit_Z-TRM3_FW%204.0%20Ver2020-A_ENG.pdf + Removing the device: +To remove the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Now start remove device in your home automation software. Start removing mode by pressing Center (confirm) button for approximately 2 seconds. The icon will appear in the display. Removing Mode is indicated in the display by some “circling” LED segments in the display until the timeout occurs after 20 seconds or the module has been removed in the network. Confirmation will show Inc/EcL in the display. If removing fails, Err (error) will appear. + CEPT (Europe) + By pressing buttons Right and Center (down and confirm) for 20 seconds, the thermostat will perform a complete factory reset. +NB! Please use this procedure only when the primary controller/ gateway is missing or otherwise inoperable. + Heatit Z-TRM3 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3802/xml + + + + + + + + + + + + + + + + + + + + + + + + + 0 + true + + + + + + Set operation mode + + + + + Set sensor mode + + + + + + + + Floor sensor type (10K NTC Default) + + + + + + + + + 3-30 (0.3C - 3.0C) Default is 5 (0.5C) + + + 50-400 (5.0C - 40.0C) Default is 50 (5.0C) + + + 50-400 (5.0C - 40.0C) Default is 400 (40.0C) + + + 50-400 (5.0C - 40.0C) Default is 50 (5.0C) + + + 50-400 (5.0C - 40.0C) Default is 400 (40.0C) + + + 50 - 400 (5.0C - 40.0C) Default is 210 (21.0C) + + + -60 - 60 (-6.0C - 6.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. + + + -60 - 60 (-6.0C - 6.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. + + + -60 - 60 (-6.0C - 6.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. + + + Show setpoint or calculated temperature on display( + + + + + 0-100 (0 - 100%) + + + 0-100 (0 - 100%) + + + 0-100 (0 - 100%) + + + 0-100 (0 - 100%) + + + + 0 (Report disabled) + 30-32767 (30-32767 seconds) + + + + 0-100 (0.1C - 10.0C) Default is 10 (1.0C) + + + + 0 (Report disabled) + 30-32767 (30-32767 seconds) + + + + 0-255 A delta value of 0 - 25.5 kWh will result in a metering report. Default is 10 (1.0 kWh) + + + + + + + + + + + + + + + + + true + + + + + + true + + + diff --git a/openzwave/thermofloor/heatit20a.xml b/openzwave/thermofloor/heatit20a.xml new file mode 100644 index 00000000..8ccaaa04 --- /dev/null +++ b/openzwave/thermofloor/heatit20a.xml @@ -0,0 +1,121 @@ + + + + + images/thermofloor/heatit20a.png + https://products.z-wavealliance.org/products/3102/ + Adding the device: +When the primary controller is set to add/remove modus press the ”INCLUSION” button once on the device + Z-Water + Heatit Z-Water is equipped with 10 relay outputs and 4 analog inputs, and a Z-Wave radio for interfacing to the wireless +Z-Wave network. +The regulator can be power supplied from a 230V AC mains connection, and is able to deliver an output supply of 24V DC. +Heatit Z-Water relay outputs are able to be freely controlled from the Z-Wave network, and can be used for several +purposes, e.g. on/off control of light, control of valve actuators for an underfloor heating system, or control of other home +automation systems. +Heatit Z-Water inputs are analog inputs for interfacing simple temperature sensors; NTC, PT1000, etc. +It is possible to configure the level and the indication of the status indicator LED in the front of the Heatit Z-Water +regulator. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3102/Manual_Heatit_Z-Water_analog%20inputs_FW%202.1_Ver2019-A_ENG.pdf + Removing the device: When the primary controller is set to add/remove modus press the ”INCLUSION” button once on the device + CEPT (Europe) + By pressing buttons Right and Center (down and confirm) for 20 seconds, the thermostat will perform a complete factory reset. +NB! Please use this procedure only when the primary controller/ gateway is missing or otherwise inoperable. + Heatit Z-Water + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3102/xml + Added ProductPic + Fixed errors + + + + + Set LED mode + + + + + + + Set Brightnes + + + This parameter decides which kind of thermistor that is connected to the input. + + + + + This parameter decides which kind of thermistor that is connected to the input. + + + + + This parameter decides which kind of thermistor that is connected to the input. + + + + + This parameter decides which kind of thermistor that is connected to the input. + + + + + -40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. + + + -40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. + + + -40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. + + + -40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. + + + + 0 (Report disabled) + Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). + + + + 0 (Report disabled) + Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). + + + + 0 (Report disabled) + Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). + + + + 0 (Report disabled) + Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). + + + + + + + + + + + + + + + + + true + + + + + + true + + + diff --git a/openzwave/thermofloor/heatitz8.xml b/openzwave/thermofloor/heatitz8.xml new file mode 100644 index 00000000..a32c80b3 --- /dev/null +++ b/openzwave/thermofloor/heatitz8.xml @@ -0,0 +1,42 @@ + + + + Heatit Z-Push Button 8 + The remote control is a Z-Wave device that can both control other Z-Wave devices and activate scenes in Gateways. Although it is controlling other devices, the device cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be added into a Z-Wave network. + http://www.openzwave.com/device-database/XXXX:XXXX:XXXX + https://www.heatit.com/z-wave/heatit-z-push-button-8/ + https://www.heatit.com/z-wave/heatit-z-push-button-8/ + images/thermofloor/Heatit-Z-Push-button-8-white.png + https://www.heatit.com/wp-content/uploads/2019/07/Manual_Heatit_Z-Push_Button_8_FW_1.26_Ver2019-A_ENG.pdf + short press any button + set controller in inclusion mode press and hold down group 2 keys for 3 seconds + set controller in exclusion mode press and hold down group 2 keys for 3 seconds + press and hold down group 2 keys for more than 10 seconds use only if controller is unavailable + https://products.z-wavealliance.org/products/3595 + CEPT + 45 125 81 (white) 45 126 81 (black) + + Made config from manual and zwave alliance + + + + + + + + + Set to 21930 to factory reset the device. + + + + + + + + + + + + + + diff --git a/openzwave/trane/TZEMT400AB32MAA.xml b/openzwave/trane/TZEMT400AB32MAA.xml new file mode 100644 index 00000000..14d8f172 --- /dev/null +++ b/openzwave/trane/TZEMT400AB32MAA.xml @@ -0,0 +1,902 @@ + + + http://www.openzwave.com/device-database/008B:5431:5452 + images/trane/TZEMT400AB32MAA.png + https://products.z-wavealliance.org/products/109/ + http://nexiahome.com/SupportCenter/Pages/supportcenter.aspx?page=support + Create the perfect climate in your home, at the perfect time, which is anytime now that there are Nexia™ Home Intelligence and Trane® ComfortLink™ thermostats. Away on vacation or business, you can check your home’s temperature settings and adjust to save energy. Heading home from the beach? Turn up the a/c so it’s nice and cool when you arrive. As the weather changes, so can your pre-set heating and cooling schedules, with a touch or a click. Now you have remote capability to control your home’s comfort and efficiency quite easily via most web-accessible computers, tablets or smart phones. + +This product is only available through a participating Trane Dealer. +This product is only available in the U.S. and Canada + + http://nexiahome.com/Products/ProductDetail.aspx?model=ComfortLink + Trane T400A + U.S. / Canada / Mexico + T400A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/109/xml + + + + + + + + + 0 = Gas/Elec, 1 = HeatPump + + + + + 0 = Gas, 1 = Elec + + + + + 0 = w/Cool, 1 = w/Heat + + + + + 0 = C, 1 = F + + + + + + + + 0 = Unlocked, 1 = Locked + + + + + Sets the minimum off time before another heating/cooling cycle can begin to provide compressor short cycle protection. The thermostat screen will display WAIT when minimum off time is being enforced. + + + + + Sets the minimum run time before a heating/cooling cycle can turn off to prevent rapid cycling. Thermostat screen will display "Cool ON" or "Heat ON" while the minimum run time is being enforced. + + + + + Sets the delta from setpoint that stage 1 heating starts. + + + + + Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1. + + + + + Sets the delta from setpoint that stage 2 heating starts. + + + + + Sets the delta from setpoint that stage 2 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2. + + + + + Sets the delta from setpoint that stage 3 heating starts. + + + + + Sets the delta from setpoint that stage 3 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 3. + + + + + Sets the delta from setpoint that stage 1 cooling starts. + + + + + Sets the delta from setpoint that stage 1 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1. + + + + + Sets the delta from setpoint that stage 2 cooling starts. + + + + + Sets the delta from setpoint that stage 2 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2. + + + + + + + + + + + Sets the minimum separation between the heating and cooling setpoints. Attempts to lower the cooling below the heating setpoint by this amount will PUSH the heating setpoint down to maintain this separation. Same for setting the heating setpoint above the cooling setpoint, it will PUSH the cooling setpoint up to maintain this separation. Settings in F. + + + + + 0 = No Setback, 1 = Setback, 2 if ESM + + + + + + + + + + + + + + Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control). Setting in F. + + + + + Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control). + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements. When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. + + + + + The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements. When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. + + + + + 0 = no 2nd stage heat, 1 = 2nd stage heat. + + + + + 0 = no aux heat, 1 = aux heat enabled. + + + + + 0 = no 2nd stage cool, 1 = 2nd stage cool + + + + + + + + + + + + + + + + + Set to 1 if running schedule (RUN is displayed on the thermostat screen). + + + + + + + + Default: + HOLD 80F / 26C + RUN 84F / xxC + ESM + + + + + + + + Heating 1 Setpoint (does this vary with ESM, etc. or is this for the "Hold" setting? + Default: + HOLD 55F / 13C + RUN 60F / xxC + ESM 64F / xxC (unless parameter xx has been changed) + + + + + Backlight Timeout is the time (in seconds) from the last + button press to the backlight going out. The time-out + can be set between 0 and 120 + seconds. When set to 0, the backlight will remain + always on. + Default: 30 + + + + + Sets the maximum heating setpoint value. Will not ramp + or accept setpoints higher than this maximum. + Minimum: 55F / xxC + Maximum: 90F / xxC + Default: 90F / 32C + + + + + Sets the minimum cooling setpoint value. Will not ramp + or accept setpoints lower than this minimum. + Minimum: 60F / xxC + Maximum: 99F / xxC + Default: 60F / 15C + + + + + + + + This is the time before any screen reverts to the Minimized + Screen (temperature display only), after you stop pushing + buttons. Minimized Screen feature is disabled by setting this + time to 0. + Default: 0 + + + + + + + + The internal temperature sensor can be calibrated to report + values different from its actual reading. The offset can + range from -7 degrees to +7 degrees. + Default: 0 + + + + + + + + + + + + + + + + + The Screen Contrast sets the contrast level of the LCD display. + The contrast can be set between 0 and 20. If the display + is too light, use a higher number. If dark lines appear on + the screen, use a lower number. + Default: 10 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 0x2c after reset + 0xf4 after reset + + + + + 0x2c after reset + 0xf4 after reset + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 0xb8 after reset + 0xe4 after reset + + + + + 0xb8 after reset + 0xe4 after reset + + + + + When enabled (set to 1), the local thermostat's scheduler + function is enabled. + Default: 0 + + + + + + + + + + + + + + + + + 0xff after reset + + + + + + + + + + + 0xff after reset + + + + + + + + + + + 0xff after reset + + + + + + + + + + + 0xff after reset + + + + + + + + + + + 0xff after reset + + + + + + + + + + + 0xff after reset + + + + + + + + + + + 0xff after reset + + + + + + + + + + + Recovery enable? + Default: 1 + 0x00 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + This value holds information about the first schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule + setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + + + + + 0 + + + diff --git a/openzwave/trane/TZEMT400BB32MAA.xml b/openzwave/trane/TZEMT400BB32MAA.xml new file mode 100644 index 00000000..d0711f73 --- /dev/null +++ b/openzwave/trane/TZEMT400BB32MAA.xml @@ -0,0 +1,770 @@ + + + http://www.openzwave.com/device-database/008B:5433:5452 + images/trane/TZEMT400BB32MAA.png + https://products.z-wavealliance.org/products/107/ + U.S. / Canada / Mexico + Trane TZEMT400BB - Thermostat + Z-Wave enabled programmable communicating thermostat. + Trane T500A + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/107/xml + Remove (non-existent) config param id 161 to 199 + + + + + + + + + 0 = Gas/Elec, 1 = HeatPump + + + + + 0 = Gas, 1 = Elec + + + + + 0 = w/Cool, 1 = w/Heat + + + + + 0 = C, 1 = F + + + + + + + + 0 = Unlocked, 1 = Locked + + + + + Sets the minimum off time before another heating/cooling cycle can begin to provide compressor short cycle protection. The thermostat screen will display WAIT when minimum off time is being enforced. + + + + + Sets the minimum run time before a heating/cooling cycle can turn off to prevent rapid cycling. Thermostat screen will display "Cool ON" or "Heat ON" while the minimum run time is being enforced. + + + + + Sets the delta from setpoint that stage 1 heating starts. + + + + + Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1. + + + + + Sets the delta from setpoint that stage 2 heating starts. + + + + + Sets the delta from setpoint that stage 2 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2. + + + + + Sets the delta from setpoint that stage 3 heating starts. + + + + + Sets the delta from setpoint that stage 3 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 3. + + + + + Sets the delta from setpoint that stage 1 cooling starts. + + + + + Sets the delta from setpoint that stage 1 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1. + + + + + Sets the delta from setpoint that stage 2 cooling starts. + + + + + Sets the delta from setpoint that stage 2 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2. + + + + + + + + + + + Sets the minimum separation between the heating and cooling setpoints. Attempts to lower the cooling below the heating setpoint by this amount will PUSH the heating setpoint down to maintain this separation. Same for setting the heating setpoint above the cooling setpoint, it will PUSH the cooling setpoint up to maintain this separation. Settings in F. + + + + + 0 = No Setback, 1 = Setback, 2 if ESM + + + + + + + + + + + + + + Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control). Setting in F. + + + + + Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control). + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements. When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. + + + + + The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements. When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. + + + + + 0 = no 2nd stage heat, 1 = 2nd stage heat. + + + + + 0 = no aux heat, 1 = aux heat enabled. + + + + + 0 = no 2nd stage cool, 1 = 2nd stage cool + + + + + + + + + + + + + + + + + Set to 1 if running schedule (RUN is displayed on the thermostat screen). + + + + + + + + Default: + HOLD 80F / 26C + RUN 84F / xxC + ESM + + + + + + + + Heating 1 Setpoint (does this vary with ESM, etc. or is this for the "Hold" setting? + Default: + HOLD 55F / 13C + RUN 60F / xxC + ESM 64F / xxC (unless parameter xx has been changed) + + + + + Backlight Timeout is the time (in seconds) from the last + button press to the backlight going out. The time-out + can be set between 0 and 120 + seconds. When set to 0, the backlight will remain + always on. + Default: 30 + + + + + Sets the maximum heating setpoint value. Will not ramp + or accept setpoints higher than this maximum. + Minimum: 55F / xxC + Maximum: 90F / xxC + Default: 90F / 32C + + + + + Sets the minimum cooling setpoint value. Will not ramp + or accept setpoints lower than this minimum. + Minimum: 60F / xxC + Maximum: 99F / xxC + Default: 60F / 15C + + + + + + + + This is the time before any screen reverts to the Minimized + Screen (temperature display only), after you stop pushing + buttons. Minimized Screen feature is disabled by setting this + time to 0. + Default: 0 + + + + + + + + The internal temperature sensor can be calibrated to report + values different from its actual reading. The offset can + range from -7 degrees to +7 degrees. + Default: 0 + + + + + + + + + + + + + + + + + The Screen Contrast sets the contrast level of the LCD display. + The contrast can be set between 0 and 20. If the display + is too light, use a higher number. If dark lines appear on + the screen, use a lower number. + Default: 10 + + + + + + + + 0xff after reset + + + + + + + + + + + 0xff after reset + + + + + + + + + + + 0xff after reset + + + + + + + + + + + 0xff after reset + + + + + + + + + + + Recovery enable? + Default: 1 + 0x00 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + This value holds information about the first schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule + setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + + + + + 0 + + + diff --git a/openzwave/trane/TZEMT524AA21MA.xml b/openzwave/trane/TZEMT524AA21MA.xml new file mode 100644 index 00000000..b976eee7 --- /dev/null +++ b/openzwave/trane/TZEMT524AA21MA.xml @@ -0,0 +1,630 @@ + + + http://www.openzwave.com/device-database/008B:5439:5452 + images/trane/TZEMT524AA21MA.png + https://products.z-wavealliance.org/products/837/ + XL624/XR624 Thermostat + XL624/XR624 + U.S. / Canada / Mexico + Z-Wave Thermostat + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/837/xml + + + + + + + + + + + + + + 0 = Gas, 1 = Elec + + + + + + + + + + + + + + + + + + + + + + Sets the minimum off time before another heating/cooling cycle can begin to provide compressor short cycle protection. The thermostat screen will display WAIT when minimum off time is being enforced. + + + + + Sets the minimum run time before a heating/cooling cycle can turn off to prevent rapid cycling. Thermostat screen will display "Cool ON" or "Heat ON" while the minimum run time is being enforced. + + + + + Sets the delta from setpoint that stage 1 heating starts. + + + + + Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1. + + + + + Sets the delta from setpoint that stage 2 heating starts. + + + + + Sets the delta from setpoint that stage 2 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2. + + + + + Sets the delta from setpoint that stage 3 heating starts. + + + + + Sets the delta from setpoint that stage 3 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 3. + + + + + Sets the delta from setpoint that stage 1 cooling starts. + + + + + Sets the delta from setpoint that stage 1 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1. + + + + + Sets the delta from setpoint that stage 2 cooling starts. + + + + + Sets the delta from setpoint that stage 2 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2. + + + + + Sets the minimum separation between the heating and cooling setpoints. Attempts to lower the cooling below the heating setpoint by this amount will PUSH the heating setpoint down to maintain this separation. Same for setting the heating setpoint above the cooling setpoint, it will PUSH the cooling setpoint up to maintain this separation. Settings in F. + + + + + 0 = No Setback, 1 = Setback, 2 if ESM + + + + + + + + Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control). Setting in F. + + + + + Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control). + + + + + The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements. When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. + + + + + The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements. When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. + + + + + 0 = no 2nd stage heat, 1 = 2nd stage heat. + + + + + + + 0 = no aux heat, 1 = aux heat enabled. + + + + + + + 0 = no 2nd stage cool, 1 = 2nd stage cool + + + + + + + Set to 1 if running schedule (RUN is displayed on the thermostat screen). + + + + + + + Default: + HOLD 80F / 26C + RUN 84F / xxC + ESM + + + + + Heating 1 Setpoint (does this vary with ESM, etc. or is this for the "Hold" setting? + Default: + HOLD 55F / 13C + RUN 60F / xxC + ESM 64F / xxC (unless parameter xx has been changed) + + + + + Backlight Timeout is the time (in seconds) from the last + button press to the backlight going out. The time-out + can be set between 0 and 120 + seconds. When set to 0, the backlight will remain + always on. + Default: 30 + + + + + Sets the maximum heating setpoint value. Will not ramp + or accept setpoints higher than this maximum. + Minimum: 55F / xxC + Maximum: 90F / xxC + Default: 90F / 32C + + + + + Sets the minimum cooling setpoint value. Will not ramp + or accept setpoints lower than this minimum. + Minimum: 60F / xxC + Maximum: 99F / xxC + Default: 60F / 15C + + + + + This is the time before any screen reverts to the Minimized + Screen (temperature display only), after you stop pushing + buttons. Minimized Screen feature is disabled by setting this + time to 0. + Default: 0 + + + + + The internal temperature sensor can be calibrated to report + values different from its actual reading. The offset can + range from -7 degrees to +7 degrees. + Default: 0 + + + + + The Screen Contrast sets the contrast level of the LCD display. + The contrast can be set between 0 and 20. If the display + is too light, use a higher number. If dark lines appear on + the screen, use a lower number. + Default: 10 + + + + + When enabled (set to 1), the local thermostat's scheduler + function is enabled. + Default: 0 + + + + + This value holds information about the first schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule + setpoints for Sundays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule + setpoints for Mondays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule + setpoints for Tuesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule + setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Wednesdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Thursdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Fridays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + This value holds information about the first schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x06004643 06:00AM 70F / 67F + 0x06001519 06:00AM 21C / 25C + + + + + This value holds information about the second schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x08003e55 08:00AM 62F / 85F + 0x0800101d 08:00AM 16C / 29C + + + + + This value holds information about the third schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x1200464e 06:00PM 70F / 78F + 0x12001519 06:00PM 21C / 25C + + + + + This value holds information about the fourth schedule setpoints for Saturdays. + + Byte 1: Hour (0-23) + Byte 2: Minute (0-59) + Byte 3: Heat Setpoint (degrees) + Byte 4: Cool Setpoint (degrees) + + Default: 0x16003e52 10:00PM 62F / 82F + 0x1600101b 10:00PM 16C / 27C + + + + + + + + + 0 + + + diff --git a/openzwave/vera/vera2.xml b/openzwave/vera/vera2.xml new file mode 100644 index 00000000..5e319a9a --- /dev/null +++ b/openzwave/vera/vera2.xml @@ -0,0 +1,23 @@ + + + http://www.openzwave.com/device-database/008C:0001:0001 + images/vera/vera2.png + https://products.z-wavealliance.org/products/961/ + U.S. / Canada / Mexico / CEPT (Europe) / U.S. / Canada / Mexico + SG200 + http://www.actiontec.com/246.html + You're on a beach in Tahiti. You turn on your phone and check in on a live feed from your security camera - or turn on porch lights. Maybe you're watching TV and flip on your pool heater and lights to get ready for a swim. Maybe from your office computer you schedule your thermostat to the right temperatures for day and night. These aren't applications of the future. They're here today, with the SG200 service gateway. + +The SG200 Service Gateway is engineered to be a lifeline to the connected home. It's loaded with all the latest connectivity standards to tie together devices and services in the home: WiFi (802.11n), Z-Wave home control standards, and Ethernet. + +And if you are a carrier, your customers will appreciate the ability to pick and choose the home automation applications they want, instead of being saddled with a static set of capabilities. The Device comes loaded with Java and OSGi, allowing you to deliver applications at your customer's purchase request (and bill monthly, if desired), providing you with additional revenue streams. + http://www.micasaverde.com/setting-up.php + Actiontec SG-200 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/118/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/119/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/961/xml + + + + diff --git a/openzwave/vision/1701.xml b/openzwave/vision/1701.xml new file mode 100644 index 00000000..3a97b24d --- /dev/null +++ b/openzwave/vision/1701.xml @@ -0,0 +1,36 @@ + + + http://www.openzwave.com/device-database/0109:0620:2006 + images/vision/1701.png + https://products.z-wavealliance.org/products/632/ + http://www.visionsecurity.com.tw/ha_products_page2_154_192.html + Z-Wave Certification - Vision Security Door Lock - EU + CEPT (Europe) + Use AES encryption to Lock/Unlock Door,have User Code management. Logging and schedule setting.HM 1701-SSX03 (Polished Brass) + +This is a radio frequency remote control electronic deadbolt with water proof design, easy to install and operate. Fit most standard door preps, no need to drill additional holes. + +User friendly for elder and young children, remote with simple icon lock and unlock, or choose manual locking, and remote can be used from indoor. The keypad buttons glow in the dark for night time visibility. + +Easily and quickly add and delete user codes right at the keypad, so it is convenient to provide a user code for temporary access. + + Features: +*13 sets of user codes/Code numbers can be any combination from 4~10 digits +*Schedule Setting/Logging +*AES encryption for Z-wave Door Lock +*Keypad shuts down after 4 incorrect code attempts. It will return to standard mode after 15 sec. +*Z-Wave 4.51 SDK +100ft line of sight +*LED visual and audible (warning sounds) feedback message definitions +*Operating temp: -10oC~50oC +*Working Voltage: 6V +*Dimensions: 150*70*57mm + + http://www.visionsecurity.com.tw/ha_products_page2_154_192.html + 1701 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/632/xml + + + + diff --git a/openzwave/vision/brg1-433.xml b/openzwave/vision/brg1-433.xml new file mode 100644 index 00000000..75450894 --- /dev/null +++ b/openzwave/vision/brg1-433.xml @@ -0,0 +1,15 @@ + + + http://www.openzwave.com/device-database/0109:1401:2014 + images/vision/brg1-433.png + https://products.z-wavealliance.org/products/762/ + Plug-in Dimmer & CT-Clamp Module(Power Meter) + U.S. / Canada / Mexico + BRG1-433 + Vision Security Dimmer BRG1-433 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/762/xml + + + + diff --git a/openzwave/vision/zd2102.xml b/openzwave/vision/zd2102.xml new file mode 100644 index 00000000..d8b3dbe5 --- /dev/null +++ b/openzwave/vision/zd2102.xml @@ -0,0 +1,67 @@ + + + http://www.openzwave.com/device-database/0109:0101:2001 + images/vision/zd2102.png + https://products.z-wavealliance.org/products/111/ + Door Sensor + http://www.visionsecurity.com.tw/ha_contact_us.html + ZD 2102 + http://www.visionsecurity.com.tw/ha_products_page2_154_159.html + CEPT (Europe) / U.S. / Canada / Mexico + The ZD2102-5 Door and Window sensor is used in any Z-Wave network to detect the opening or closing of a door or window. Special Design can fit most of door/window frame. The primary sensing element is a magnetic reed switch, the ZD2102-5 is supplied with the sensor, sensor mounting bracket and the trigger magnet. An additional set of sensor inputs are provided through a 2 position screw terminal and can be used to expand the sensor capability to multiple inputs. The ZD2102-5 is powered by a single CR123A Lithium Battery (supplied with unit, battery life is more than 5 years) and is intended for indoor use only. The ZD2102-5 features tamper proof switch, low battery warning and can be firmware updated over the air. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/90/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/111/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/702/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/779/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/848/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/988/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1705/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2823/xml + + https://products.z-wavealliance.org/products/779/ + ZD2102IN + CEPT (Europe) / India + https://products.z-wavealliance.org/products/848/ + Japan + ZD2102JP + https://products.z-wavealliance.org/products/988/ + The ZD2102-5 is forced awake by opening the rear cover, the red LED will stay on and the 2102-5 will stay awake for 10 seconds. The ZD2102-5 will send “Wake Up Notification”. If ZD2102-5 receives a “Wake Up No More Information” command then the red LED will go off and it will go to sleep. +Auto Wake Up: The wakeup interval is user settable from 10 minutes to 1 week using COMMAND_CLASS_WAKE_UP, Interval increment is 3 minutes. + For “Exclusion” (removing from) a network: Put the Z-Wave™ network controller into “exclusion” mode, following its instructions. To delete the ZD2102-5 from your controller press the program switch of ZD2102-5 for at least 1 second to be excluded. Note: All user and network settings will be cleared and the device reset to factory setting defaults when the device is excluded. + For “Inclusion” (adding to) a network: Put the Z-Wave™ network controller into “inclusion” mode following its instructions. To add the ZD2102-5 to your controller press the program switch of ZD2102-5 to send the Node Information Frame (NIF). After sending NIF, the network controller will send the auto inclusion request; otherwise, ZD2102-5 will go to sleep after 15 seconds. + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2823/ZD 2102-5_R4_20170913 (RED).pdf + ZD2102EU-5 + Factory Default Reset: Trigger the rear cover switch to send the Alarm Report and trigger the reed switch (close & open) 5 times in 10 seconds, ZD2102-5 will send the “Device Reset Locally Notification” command and reset to the factory default condition. Please use this procedure only when the network primary controller is missing or otherwise inoperable! + https://products.z-wavealliance.org/products/2823/ + ZD2102JP-5 + U.S. / Canada / Mexico / Japan + + + + + External Switch Status + + + + + + + + true + + + + + + false + + + + + + + + + diff --git a/openzwave/vision/zd2105us5.xml b/openzwave/vision/zd2105us5.xml new file mode 100644 index 00000000..55d1e76c --- /dev/null +++ b/openzwave/vision/zd2105us5.xml @@ -0,0 +1,42 @@ + + + http://www.openzwave.com/device-database/0109:2201:2022 + images/vision/zd2105us5.png + https://products.z-wavealliance.org/products/1727/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1727/ZD 2105-5_V1-20160329.pdf + ZD2105US-5 + *If the cover of sensor is removed, the tamper switch will send signal according the Status/Signal table, and the LED will go solid and ZD2105 will send “Wake Up Notification” after 10 seconds. If ZD2105 received “Wake Up No More Information” command, the red LED will go off. If ZD2105 did not receive”Wake Up No More Information” command after 10 seconds the red LED will go off. + +*Use “Wake Up” command to set up the awaking time and send the wake up notification to controller. User can use command to change the auto wake up from 10 minutes to 1 week, Interval increment is 3 minutes. + The ZD2105US-5 Recessed Door sensor can be used in any Z-Wave network, to detect the opening or closing of a door or window. Special Design can fit most door/window frames. This sensor monitors door/window and send Z-Wave™ signal when door or window is opened and closed. Recessed Door Sensors are easily installed inside the door or window frame to keep the sensor hidden from view. When the device is securely included into Z-Wave network, above communication will be encrypted. + For “Exclusion” from (removing from) a network: Put the Z-Wave™ Interface Controller into “exclusion” mode, and following its instruction to delete the ZD2105 from your controller. Press the Program Switch of ZD2105 for 1 second at least to be excluded. Note: All user and network settings will be cleared and the device reset to factory setting defaults when the device is excluded. + U.S. / Canada / Mexico + For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into “inclusion” mode, and following its instruction to add the ZD2105 to your controller. To get in the “inclusion” mode, please press the Program Switch of ZD2105 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2105 will go to sleep after 20 seconds. + Door Sensor + *open the cover to send the Alarm Report and trigger the reed switch (close & open) 10 times in 10 seconds, ZD2105 will send the “Device Reset Locally Notification” command and reset to the factory default. + * Please use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1727/xml + + + + + + + + true + + + + + + + + + + + diff --git a/openzwave/vision/zd2201.xml b/openzwave/vision/zd2201.xml new file mode 100644 index 00000000..65fe2d09 --- /dev/null +++ b/openzwave/vision/zd2201.xml @@ -0,0 +1,72 @@ + + + http://www.openzwave.com/device-database/0109:1F10:201F + images/vision/zd2201.png + https://products.z-wavealliance.org/products/2480/ + CEPT (Europe) / Japan + Factory Default Reset: +*Open the rear cover to send the Alarm Report and then press the program switch 10 times in 10 seconds, ZD2301 will send the “Device Reset Locally” command and reset to the factory default. +* Please use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + Use “Wake Up” command to set up the awaking time and send the wake up notification to controller. User can use command to change the auto wake up from 10 minutes to 1 week, Interval increment is 3 minutes. + The Vision’s wireless 4 in 1 Multi-Sensor (door window contact sensor, humidity sensor, temperature sensor, and light sensor) of the home security device. This multi-sensor sends Z-Wave™ signal when door or window is opened and closed or humidity, temperature, luminous change. When the device is secure included into Z-Wave network, above communication will be encrypted. + ZD2201JP-5 + 4 in 1 Door Sensor + For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into “inclusion” mode, and following its instruction to add the ZD2301 to your controller, to get in the “inclusion” mode. Press the program switch of ZD2301 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2301 will go to sleep after 20 seconds. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2480/ZD 2201-5_R1_20150812.pdf + For “Exclusion” from (removing from) a network: Put the Z-Wave™ Interface Controller into “exclusion” mode, and following its instruction to delete the ZD2301 from your controller. Press the program switch of ZD2301 for 1 second at least to be excluded. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1566/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2480/xml + + + + + + + + + + + Threshold change in temperature to induce an automatic report. + 1 to 50 ( Set up from 0.1C to 5C) + + + + Threshold change in humidity to induce an automatic report. + 1 to 50 ( Set up from 1%-50%) + + + + + Threshold change in luminance to induce an automatic report. + 0 is disabled. + 5 to 50 ( Set up from 5%-50%) + + + + + + + true + + + + + + false + + + + + + false + + + + + + + + + diff --git a/openzwave/vision/zd2301.xml b/openzwave/vision/zd2301.xml new file mode 100644 index 00000000..d53fb3bc --- /dev/null +++ b/openzwave/vision/zd2301.xml @@ -0,0 +1,80 @@ + + + http://www.openzwave.com/device-database/0109:1F20:201F + images/zipato/zd2301.png + https://products.z-wavealliance.org/products/2346/ + Press the Program SW, the LED will flash one time and ZD2301 will send “Wake Up Notification” after 5 seconds. If ZD2301 received “Wake Up No More Information” command then the ZD2301 will go to sleep or it will wait 10 seconds then go to sleep. It will precede all the commands after sending the “Wake Up Notification” + CEPT (Europe) + All user and network settings will be cleared and the device reset to factory +defaults when the device is excluded. + +Please use this procedure only in the event if the network +controller is missing or is otherwise inoperable. + Zipato 4 in 1 Door Sensor + Put the Z-WaveTM Interface +Controller into “exclusion” mode, and following its instruction to delete the ZD2301 from your controller. Press the program switch of ZD2301 for 1 second at least to be excluded. + Door/Window, humidity, temperature and luminance sensor. +* Primarily used as dry contact door/window sensor. +* Very low power consumption +* LED indicator +* Easy installation + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2346/zp2301.pdf + Put the Z-WaveTM Interface Controller into +“inclusion” mode, and following its instruction to add the ZD2301 to your controller. To get in the “inclusion” mode, the distance between sensor and controller is suggested to be one meter. Press the program switch of ZD2301 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2301 will go to sleep after 20 seconds. + vs-zd2301.eu + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1334/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2346/xml + + + + + + + + + + + Threshold change in temperature to induce an automatic report. + 1 to 50 ( Set up from 0.1C to 5C) + + + + Threshold change in humidity to induce an automatic report. + 1 to 50 ( Set up from 1%-50%) + + + + + Threshold change in luminance to induce an automatic report. + 0 is disabled. + 5 to 50 ( Set up from 5%-50%) + + + + + + + true + + + + + + false + + + + + + false + + + + + + + + + diff --git a/openzwave/vision/zf5201.xml b/openzwave/vision/zf5201.xml new file mode 100644 index 00000000..f3b618b8 --- /dev/null +++ b/openzwave/vision/zf5201.xml @@ -0,0 +1,14 @@ + + + + + + true + + + + + + + + diff --git a/openzwave/vision/zg8101.xml b/openzwave/vision/zg8101.xml new file mode 100644 index 00000000..412dec56 --- /dev/null +++ b/openzwave/vision/zg8101.xml @@ -0,0 +1,21 @@ + + + + + + + + + true + + + + + + + + + diff --git a/openzwave/vision/zl7101us.xml b/openzwave/vision/zl7101us.xml new file mode 100644 index 00000000..d4126cfa --- /dev/null +++ b/openzwave/vision/zl7101us.xml @@ -0,0 +1,25 @@ + + + http://www.openzwave.com/device-database/0109:0803:2008 + images/vision/zl7101us.png + https://products.z-wavealliance.org/products/877/ + ZL 7101 Z-Wave Plug-in Dimmer Module + +Features: +*Plug-In Module +*Z-wave control & AC power output +*Suitable for most bulb type appliance +*Adjusting the light via the middle button +*Protection function via the middle button +*Max load output: 300W, 60Hz +*Input: 120VAC +*Dimensions: 100*60*37mm + + Dimmer Module ZL7101US + U.S. / Canada / Mexico + ZL7101US + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/877/xml + + + diff --git a/openzwave/vision/zl7201us.xml b/openzwave/vision/zl7201us.xml new file mode 100644 index 00000000..73708f60 --- /dev/null +++ b/openzwave/vision/zl7201us.xml @@ -0,0 +1,23 @@ + + + http://www.openzwave.com/device-database/0109:0703:2007 + images/vision/zl7201us.png + https://products.z-wavealliance.org/products/876/ + ZL7201US + http://www.visionsecurity.com.tw/ha_products_page2_154_196.html + U.S. / Canada / Mexico + ZL7201 Z-Wave Plug-in ON/OFF + +Features: +*Basic functions are similar to ZL7101 +*Suitable for most of Appliance +*Max Load output: 600W, 60Hz +*Input: 120VAC +*Motor load: 1/2 HP +*Resistive load: 15A + Appliance Module ZL7201US + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/876/xml + + + diff --git a/openzwave/vision/zl7261.xml b/openzwave/vision/zl7261.xml new file mode 100644 index 00000000..2c2d40aa --- /dev/null +++ b/openzwave/vision/zl7261.xml @@ -0,0 +1,23 @@ + + + + + + + + Choose how often you want to send automatic reports, in seconds. + Defaults to 60 seconds. + + + Minimum change in wattage to induce an automatic report. + Defaults to 50 watts. + + + + + + + + + + diff --git a/openzwave/vision/zl7431.xml b/openzwave/vision/zl7431.xml new file mode 100644 index 00000000..29778eaf --- /dev/null +++ b/openzwave/vision/zl7431.xml @@ -0,0 +1,29 @@ + + + http://www.openzwave.com/device-database/0109:0C02:200C + images/vision/zl7431.png + https://products.z-wavealliance.org/products/1792/ + U.S. / Canada / Mexico + Vision ZL7431US In-wall 1 relay switch + ZL7431US + ZL7431US + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1792/xml + + + + + + + + + + + + + + + + + + diff --git a/openzwave/vision/zl7432us.xml b/openzwave/vision/zl7432us.xml new file mode 100644 index 00000000..55ce7dc7 --- /dev/null +++ b/openzwave/vision/zl7432us.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/0109:1717:2017 + images/vision/zl7432us.png + https://products.z-wavealliance.org/products/1807/ + Vision Security ZL7432US In-wall 2 relays switch + ZL7432US + U.S. / Canada / Mexico + ZL7432US In-wall 2 relays switch + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1807/xml + + + diff --git a/openzwave/vision/zm1601eu.xml b/openzwave/vision/zm1601eu.xml new file mode 100644 index 00000000..64bee92a --- /dev/null +++ b/openzwave/vision/zm1601eu.xml @@ -0,0 +1,53 @@ + + + http://www.openzwave.com/device-database/0109:0505:2005 + images/vision/zm1601eu.png + https://products.z-wavealliance.org/products/1009/ + Siren with LED strobe light + ZM1601EU-5 + All user and network settings will be cleared and the device reset to factory defaults when the device is excluded. + CEPT (Europe) + It is FLiRS device + For “Inclusion” (adding to) a network, put the Z-Wave™ network controller into “inclusion” mode, and following its instruction to add the ZM 1601 to your controller. To get the ZM 1601 in the “inclusion” mode, open the bracket and press the program switch of ZM 1601 for 1 second at least & release to be included. After waiting a few seconds the LED Setting Lighting should go off, if not, please try again. (After sending the Z-Wave NIF one time if the ZM1601 is not included it will send 4 times Network Wide Inclusion request every 4 ~ 6 seconds for auto inclusion. The orange LED will flash again if the siren has not been included or the orange LED will go off after inclusion.) + For “Exclusion” from (removing from) a network: Set up the Z-Wave™ network controller into “exclusion” mode, and following its instruction to delete the ZM 1601 from your controller. Press the program switch of ZM 1601 for 1 second at least & release to be excluded. Note: a. LED setting light will flash (orange color) continuously in Exclusion condition for 25 seconds. b. All user and network settings will be cleared and the device reset to factory defaults when the device is excluded. + This product will sound a loud siren and flash a strobe light when an alarm message or alert is received on any Z-Wave™ enabled network. This siren is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave™ enabled network. Configuration modes are provided to select; Strobe, Siren or Both and to set Alarm Auto Stop time. Features also include Self-Protection (tamper proof) alert and Battery Life Alert. 105dB siren at 1 meter. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1009/ZM 1601 Siren_20140407-500 series.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1009/xml + + + + + + Defines the reaction of the siren: turn either Siren sound, Strobe light, or both when triggered + + + + + + Defines the auto time out of the alarm indication + + + + + + + + + + true + + + + + + true + + + + + + true + + + diff --git a/openzwave/vision/zm1601eu5.xml b/openzwave/vision/zm1601eu5.xml new file mode 100644 index 00000000..6fada10f --- /dev/null +++ b/openzwave/vision/zm1601eu5.xml @@ -0,0 +1,64 @@ + + + http://www.openzwave.com/device-database/0109:0508:2005 + images/vision/zm1601eu5.png + https://products.z-wavealliance.org/products/1278/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1278/ZM 1601-5 Siren_20150602.pdf + ZM1601US-5 + removing the back cover of the ZM1601 to get into “Awake” mode + Put the Z-Wave™ Interface Controller into “inclusion” mode, and following its instruction to add the ZM 1601 to your controller. To get in the “inclusion” mode, the distance between siren and controller is suggested to be in one meter. Open the bracket and press the program switch of ZM 1601 for 1 second at least & release to be included. After setting, the LED Setting Light should go off, + Wireless Siren & Strobe Alarm, Battery Type + U.S. / Canada / Mexico + Features: + +*Loud audible alarm>105dB@1 meter +*LED strobe lighting +*Low battery detection +*Siren for Battery Back-Up +*100ft line of sight +*LED Status Indicator +*Operating temp: -15oC~60oC +*Working Voltage: 6V +*Dimensions: 116*77*40mm + + + Set up the Z-Wave™ Interface Controller into “exclusion” mode, and following its instruction to delete the ZM 1601 from your controller. Press the program switch of ZM 1601 for 1 second at least & release to be excluded. After setting The LED setting light will flash again + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1278/xml + + + + + + Defines the reaction of the siren: turn either Siren sound, Strobe light, or both when triggered + + + + + + Defines the auto time out of the alarm indication + + + + + + + + + + true + + + + + + true + + + + + + true + + + diff --git a/openzwave/vision/zm1602eu.xml b/openzwave/vision/zm1602eu.xml new file mode 100644 index 00000000..33b64b56 --- /dev/null +++ b/openzwave/vision/zm1602eu.xml @@ -0,0 +1,30 @@ + + + + + + Defines the reaction of the siren: [0] Strobe and Siren, [1] Siren, [2] Strobe (Default setting: 0) + + + Defines the auto time out of the alarm indication: [0] 30 seconds, [1] 60 seconds, [2] 120 seconds, [3] Continuous (Default setting: 0) + + + + + + true + + + + + + true + + + + + + true + + + diff --git a/openzwave/vision/zm1602eu5.xml b/openzwave/vision/zm1602eu5.xml new file mode 100644 index 00000000..389d05ef --- /dev/null +++ b/openzwave/vision/zm1602eu5.xml @@ -0,0 +1,70 @@ + + + http://www.openzwave.com/device-database/0109:0908:2009 + images/vision/zm1602eu5.png + https://products.z-wavealliance.org/products/2901/ + U.S. / Canada / Mexico + ZM1602US-5 + Put the Z-Wave™ Interface Controller into “inclusion” mode, and following its instruction to add the ZM 1602 to your controller. To get in the “inclusion” mode, the distance between siren and controller is suggested to be in one meter. Open the bracket and press the program switch of ZM 1602 for 1 second at least & release to be included. After setting, the LED Setting Lighting should go off, + Features: + +*Loud audible alarm>105dB@1 meter +*LED strobe lighting +*Low battery detection +*Siren for Battery Back-Up +*100ft line of sight +*LED Status Indicator +*Operating temp: -15oC~60oC +*Working Voltage: 6V +*Dimensions: 116*77*40mm + + Wireless Siren + removing the back cover of the ZM1602 to get into “Awake” mode, + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2901/ZM1602-5 Siren_R3_20180417 (RED).pdf + Set up the Z-Wave™ Interface Controller into “exclusion” mode, and following its instruction to delete the ZM 1602 from your controller. Press the Tamper Switch of ZM 1602 for 1 second at least & release to be excluded. + This device can’t be reset manually. It is reset to factory defaults when it is excluded. Please use this procedure only when the network primary controller is missing or otherwise inoperable. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2901/xml + + + + + + Defines the reaction of the siren: turn either Siren sound, Strobe light, or both when triggered + + + + + + Defines the duration of siren time when triggered + + + + + + + + + + true + + + + + + true + + + + + + true + + + + + + + + + diff --git a/openzwave/vision/zp3102.xml b/openzwave/vision/zp3102.xml new file mode 100644 index 00000000..98410242 --- /dev/null +++ b/openzwave/vision/zp3102.xml @@ -0,0 +1,74 @@ + + + http://www.openzwave.com/device-database/0109:0201:2002 + images/vision/zp3102.png + https://products.z-wavealliance.org/products/84/ + The ZP3102 is a Z-Wave enabled motion detector and temperature sensor. The motion detector has 120 degrees of horizontal visibility and 60 degrees of vertical visibility. The temperature sensor that is built in to the ZP3102 is capable of reporting in both Celsius and Fahrenheit scales, and may be queried for the temperature and it will report it automatically when it detects changes. The sensor is battery operated and includes the ability to report the battery level and will transmit an alert signal if the battery assumes a critically low level. The ZP3102 is future-proofed by also supporting the ability to have its firmware updated over the Z-Wave network. + http://www.visionsecurity.com.tw/ha_products_page2_154_161.html + http://www.visionsecurity.com.tw/ha_products_page2_154_161.html + CEPT (Europe) / U.S. / Canada / Mexico + Motion Detector (with Temperature Sensor) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/72/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/84/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/703/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/728/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/804/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/847/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1070/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1702/xml + + ZP 3102 + https://products.z-wavealliance.org/products/728/ + 2 + CEPT (Europe) / Brazil + https://products.z-wavealliance.org/products/804/ + ZP3102IN + India + https://products.z-wavealliance.org/products/847/ + Japan + ZP3102JP + https://products.z-wavealliance.org/products/1702/ + ZP3102US-5 + Remove the rear cover to wake up the device, or set the wake up interval time from 10 minutes to 1 week. The battery will be drained quickly if you fail to replace the cover after using that method to wake up the device. + + Removing the rear cover to wake up the device. Press Program Switch 10 times within 10 seconds, ZP3102 will go back to factory default. (This is to be used only in the case of the primary controller being inoperable or otherwise unavailable.) + CEPT (Europe) / U.S. / Canada / Mexico + Put the Z-Wave Interface Controller into 'inclusion' mode, and follow its instructions to add the ZP3102 to your Z-Wave network. For a successful inclusion, it is suggested to have the sensor and your Z-Wave controller about one meter apart. Press the Program Switch of the ZP3102 (refer to the manual for the location of the program switch) ready the ZP3102 for inclusion into the Z-Wave network. If inclusion does not take place or is unsuccessful within 20 seconds, the ZP3102 will go to sleep; if this happens, simply repeat pressing the program switch to try again. + Put the Z-Wave Interface Controller into “exclusion” mode, and following its instruction to delete the ZP3102 to your Z-Wave network. Press the Program Switch of ZP3102 once to be excluded. The LED on the ZP3102 should start to flash. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1702/ZP 3102-5 PIR_R3_500 Series_20150724.pdf + + + + + + Time until an associated device will turn off if no new movement is detected + + + Report temperature in Celcius or Fahrenheit + + + + + Sensitivity 1-7 (1 = most sensitive, 7 = most insensitive. 4 is default) + + + -10 to -1, 0 to 10 (Signed decimal: 246 to 255, 0 to 10) + + + + + + true + + + + + + + + + diff --git a/openzwave/vision/zp3111.xml b/openzwave/vision/zp3111.xml new file mode 100644 index 00000000..22110d15 --- /dev/null +++ b/openzwave/vision/zp3111.xml @@ -0,0 +1,92 @@ + + + http://www.openzwave.com/device-database/0109:2101:2021 + images/vision/zp3111.png + https://products.z-wavealliance.org/products/2479/ + CEPT (Europe) / U.S. / Canada / Mexico / Japan + To add the ZP3111 to the Z-Wave network (inclusion), place the Z-Wave primary controller into inclusion mode. Press the Program Switch of ZP3111 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise, ZP3111 will go to sleep after 20 seconds. + To remove the ZP3111 from the Z-Wave network (exclusion), place the Z-Wave primary controller into “exclusion” mode, and following its instruction to delete the ZP3111 to the controller. Press the Program Switch of ZP3111 once to be excluded. + Use “Wake Up” command to set up the awaking time (from 10 minutes to 1 week) and send the wake up notification to controller + Remove cover to trigged tamper switch, LED flash once & send out Alarm Report. Press Program Switch 10 times within 10 seconds, ZP3111 will send the “Device Reset Locally Notification” command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.) + + + ZP3111JP-5 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2479/ZP3111-5_R2_20170316.pdf + 4in1 PIR Sensor + * Includes Motion, Temperature, Humidity, and Light sensor +* 360 degree detection (suitable for ceiling fixture) +* Compact Size: 59*59*41mm +* 2*AAA Battery +* Low Battery Detection +* LED Status Indicator +* 100feet line of sight + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1572/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1744/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2479/xml + + + + + + + + + + + + Threshold change in temperature to induce an automatic report. + 1 to 50 ( Set up from 0.1C to 5C) + + + + Threshold change in humidity to induce an automatic report. + 1 to 50 ( Set up from 1%-50%) + + + + + Threshold change in luminance to induce an automatic report. + 0 is disabled. + 5 to 50 ( Set up from 5%-50%) + + + + + Value from 1 to 255 minutes to setup the re-trigger time when there is no movement detected in the period of time. + + + + + Sensitivity of the integrated PIR sensor. + 1 to 7 ( 1 = Most Sensitive ) + + + + + 1 - Turn Off LED + 2 - Breathing Light Mode (High Battery Consumption) + 3 - Quick Flash on Sensor Reporting or Motion Trigger + + + + + + + true + + + + + + + + + diff --git a/openzwave/vision/zr1202us.xml b/openzwave/vision/zr1202us.xml new file mode 100644 index 00000000..bd1d4699 --- /dev/null +++ b/openzwave/vision/zr1202us.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/0109:1203:2012 + images/vision/zr1202us.png + https://products.z-wavealliance.org/products/990/ + U.S. / Canada / Mexico + Vision Security Repeater ZR1202US + Repeater + ZR1202US + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/990/xml + + + diff --git a/openzwave/vision/zs5101eu.xml b/openzwave/vision/zs5101eu.xml new file mode 100644 index 00000000..873bcd66 --- /dev/null +++ b/openzwave/vision/zs5101eu.xml @@ -0,0 +1,12 @@ + + + + true + + + + + + + + diff --git a/openzwave/vision/zs610eu.xml b/openzwave/vision/zs610eu.xml new file mode 100644 index 00000000..0015934a --- /dev/null +++ b/openzwave/vision/zs610eu.xml @@ -0,0 +1,27 @@ + + + http://www.openzwave.com/device-database/0109:0403:2004 + images/vision/zs610eu.png + https://products.z-wavealliance.org/products/860/ + Smoke Detector + ZS610EU + ZS 6101 Smoke Detector + +Features: +*Photoelectron Smoke Detect +*Smoke sensitivity: 0.5%/ft~4.0%/ft +*Low battery detection +*LED Status Indicator +*100ft Line of Sight +*Z-Wave 5.02 SDK +*100ft line of sight +*Operating temp: -10oC~60oC +*Working Voltage: 3V +*Dimensions: 120*120*48.2mm + http://www.visionsecurity.com.tw/ha_products_page2_154_191.html + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/860/xml + + + diff --git a/openzwave/vision/zu1401jp.xml b/openzwave/vision/zu1401jp.xml new file mode 100644 index 00000000..50488f31 --- /dev/null +++ b/openzwave/vision/zu1401jp.xml @@ -0,0 +1,14 @@ + + + http://www.openzwave.com/device-database/0109:0101:1001 + images/vision/zu1401jp.png + https://products.z-wavealliance.org/products/849/ + Japan + ZU1401JP + Z-wave USB dongle + USB Dongle + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/849/xml + + + diff --git a/openzwave/vitrum/vitrumI-Dimmer.xml b/openzwave/vitrum/vitrumI-Dimmer.xml new file mode 100644 index 00000000..12525fa4 --- /dev/null +++ b/openzwave/vitrum/vitrumI-Dimmer.xml @@ -0,0 +1,34 @@ + + + http://www.openzwave.com/device-database/010A:4900:1100 + images/vitrum/vitrumI-Dimmer.png + https://products.z-wavealliance.org/products/121/ + http://www.ivitrum.com/index.php?file=contact + Vitrum I EU dimmer wireless + 1 channel Dimmer - 503 BOX - Wireless. ne button Smart Glass Switch +Switch Device for Modbus System +with one switche for lighting control +or alternatively, sequential +pre-programmed settings +Configurable aural feedback + + +Available in British Standard & European Standard; +Dimensions:BS 95x95mm; EU 125x95mm; +Dimming is by the "iPod ®-like" touch control +Capacitive technology to adjust lighting level + CEPT (Europe) + http://www.ivitrum.com/index.php?file=prodotti&form_id_products=12&qt=1 + Vitrum I EU + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/121/xml + + + + + + true + true + + + diff --git a/openzwave/vitrum/vitrumI-Switch.xml b/openzwave/vitrum/vitrumI-Switch.xml new file mode 100644 index 00000000..17e787a3 --- /dev/null +++ b/openzwave/vitrum/vitrumI-Switch.xml @@ -0,0 +1,33 @@ + + + http://www.openzwave.com/device-database/010A:5100:1200 + images/vitrum/vitrumI-Switch.png + https://products.z-wavealliance.org/products/8/ + CEPT (Europe) + http://www.ivitrum.com/index.php?file=contact + http://www.vitrum.com/eng/content/vitrum-i + Vitrum I EU on-off wireless + 1 channel Switch - 503 BOX - ZWavene button Smart Glass Switch +Switch Device for Modbus System +with one switche for lighting control +or alternatively, sequential +pre-programmed settings +Configurable aural feedback + +Available in British Standard & European Standard; +Dimensions:BS 95x95mm; EU 125x95mm; +Dimming is by the "iPod ®-like" touch control +Capacitive technology to adjust lighting level. + 01E010020 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/8/xml + + + + + + true + true + + + diff --git a/openzwave/vitrum/vitrumII-Dimmer.xml b/openzwave/vitrum/vitrumII-Dimmer.xml new file mode 100644 index 00000000..327edb16 --- /dev/null +++ b/openzwave/vitrum/vitrumII-Dimmer.xml @@ -0,0 +1,41 @@ + + + http://www.openzwave.com/device-database/010A:8A00:2100 + images/vitrum/vitrumII-Dimmer.png + https://products.z-wavealliance.org/products/94/ + 2 channel Dimmer - 503 BOX - ZWave. Smart Switch II + +Two buttons Smart Glass Switch +Switch Device for Modbus System +with two switches for lighting control +or alternatively, sequential +pre-programmed settings +Configurable aural feedback + + +Available in British Standard & European Standard; +Dimensions:BS 95x95mm; EU 125x95mm; +On/Off by "One Touch" +Dimming is by the "iPod ®-like" touch control +Capacitive technology to adjust lighting level + Vitrum II BS + Vitrum II EU dimmer wireless + http://www.ivitrum.com/index.php?file=prodotti&form_id_products=13&qt=1 + CEPT (Europe) + http://www.ivitrum.com/index.php?file=contact + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/94/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/120/xml + + https://products.z-wavealliance.org/products/120/ + Vitrum II EU + CEPT (Europe) + + + + + true + true + + + diff --git a/openzwave/vitrum/vitrumII-RollerBlind.xml b/openzwave/vitrum/vitrumII-RollerBlind.xml new file mode 100644 index 00000000..49c84c27 --- /dev/null +++ b/openzwave/vitrum/vitrumII-RollerBlind.xml @@ -0,0 +1,26 @@ + + + http://www.openzwave.com/device-database/010A:5A00:1300 + images/vitrum/vitrumII-Blind.png + https://products.z-wavealliance.org/products/7/ + Switch with two touch keys for control of curtains and roller blinds +Two-button roll-down shutters and curtains control +Touch control with capacitive technology and concave surface for tactile identification of the switch itself +Acoustic feedback signal +Crown backlit by low-consumption LEDs + VITRUM II Control of Roller Blinds - EU BOX + http://www.vitrum.com/eng/content/vitrum-ii-roll-down-shutter-and-curtain-control + CEPT (Europe) + http://www.vitrum.com/eng/content/vitrum-ii-roll-down-shutter-and-curtain-control + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/7/xml + + + + + + true + true + + + diff --git a/openzwave/vitrum/vitrumII-Switch.xml b/openzwave/vitrum/vitrumII-Switch.xml new file mode 100644 index 00000000..afcc061c --- /dev/null +++ b/openzwave/vitrum/vitrumII-Switch.xml @@ -0,0 +1,37 @@ + + + http://www.openzwave.com/device-database/010A:5200:1200 + images/vitrum/vitrumII-Switch.png + https://products.z-wavealliance.org/products/87/ + Vitrum II EU on-off + http://www.ivitrum.com/index.php?file=contact + CEPT (Europe) + Vitrum II EU on-off wireless + http://www.ivitrum.com/index.php?file=prodotti&form_id_products=13&qt=1 + 2 channel Switch - 503 BOX - ZWave. Smart Switch II + +Two buttons Smart Glass Switch +Switch Device for Modbus System +with two switches for lighting control +or alternatively, sequential +pre-programmed settings +Configurable aural feedback + + +Available in British Standard & European Standard; +Dimensions:BS 95x95mm; EU 125x95mm; +On/Off by "One Touch" +Dimming is by the "iPod ®-like" touch control +Capacitive technology to adjust lighting level + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/87/xml + + + + + + true + true + + + diff --git a/openzwave/vitrum/vitrumIII-Dimmer.xml b/openzwave/vitrum/vitrumIII-Dimmer.xml new file mode 100644 index 00000000..32ec163a --- /dev/null +++ b/openzwave/vitrum/vitrumIII-Dimmer.xml @@ -0,0 +1,9 @@ + + + + + true + true + + + diff --git a/openzwave/vitrum/vitrumIII-Switch.xml b/openzwave/vitrum/vitrumIII-Switch.xml new file mode 100644 index 00000000..32ec163a --- /dev/null +++ b/openzwave/vitrum/vitrumIII-Switch.xml @@ -0,0 +1,9 @@ + + + + + true + true + + + diff --git a/openzwave/vitrum/vitrumIV-Switch.xml b/openzwave/vitrum/vitrumIV-Switch.xml new file mode 100644 index 00000000..32ec163a --- /dev/null +++ b/openzwave/vitrum/vitrumIV-Switch.xml @@ -0,0 +1,9 @@ + + + + + true + true + + + diff --git a/openzwave/vitrum/vitrumVI-Switch.xml b/openzwave/vitrum/vitrumVI-Switch.xml new file mode 100644 index 00000000..32ec163a --- /dev/null +++ b/openzwave/vitrum/vitrumVI-Switch.xml @@ -0,0 +1,9 @@ + + + + + true + true + + + diff --git a/openzwave/waynedalton/WDTC-20.xml b/openzwave/waynedalton/WDTC-20.xml new file mode 100644 index 00000000..b9887aa8 --- /dev/null +++ b/openzwave/waynedalton/WDTC-20.xml @@ -0,0 +1,10 @@ + + + + + + + 0 + + + diff --git a/openzwave/wenzhou/sm103.xml b/openzwave/wenzhou/sm103.xml new file mode 100644 index 00000000..cc354b5b --- /dev/null +++ b/openzwave/wenzhou/sm103.xml @@ -0,0 +1,38 @@ + + + + + + Defines the level in the event sent when the sensor is triggered. Default is 99 (full brightness for a Z-Wave dimmer). 100-127 will set device on to the last value it was when turned off. + + + + + On Time sets the number of seconds the sensor stays alerted before the off event is sent. + + + + + Enable/Disable power saving mode. 0 enables. + + + + + + + true + + + + + + false + + + + + + + + + diff --git a/openzwave/wenzhou/tsp01.xml b/openzwave/wenzhou/tsp01.xml new file mode 100644 index 00000000..65ae22b1 --- /dev/null +++ b/openzwave/wenzhou/tsp01.xml @@ -0,0 +1,113 @@ + + + http://www.openzwave.com/device-database/0118:0002:0002 + images/wenzhou/tsp01.png + https://products.z-wavealliance.org/products/839/ + TSM02U + CEPT (Europe) / U.S. / Canada / Mexico + PIR, door/window, temperature and illumination, 4 sensors function in one. + + - (1)Door/window (2)PIR (3)illumination and (4)temperature functions in one sensor + - Adopt newest Z-wave 400 series chip, support multichannel operation and higher data rate (9.6/40/100kbps) + - Higher output power (+2.5dBm output power as compared to -2.5dBm 300 series Z-wave module) to enhance the communication range + - 1500mA CR123A lithium battery to guarantee 2 year battery life + - Built in light sensor while applied to light control + - Adopt Z-Wave protocol to secure the success of wireless two way communication + - With Tamper proof protection + - Easy install + - Low battery indication + - Auto report the open/close status and battery status + - FCC part15.249 / EN300 220-1/ certification + - NCC + TSM02U Multi-Sensor + http://www.tkbhome.com/?cn-p-d-257.html + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/838/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/839/xml + + + + + + + + + Setting the BASIC command value to turn on the light. The 0xFF (255) means turn on the light. + For dimmer equipment 1 to 100 means the light strength. + + + + PIR sensitivity settings. + 0 means disable the PIR motion. + 1 means the lowest sensitivity. + 99 means the highest sensitivity. + High sensitivity means can detect long distance, but if there is more noise signal in the environment, it will re-trigger too frequently. + + + Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower than + the threshold, the device will turn on the light. + 0 means turn off illumination detected function and never turn on the light. + 1 means darkest. + 99 means brightest. + 100 means turn off illumination detected function. And always turn on the light. + * Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. + + + Bit 0: 1 means security mode; 0 means home automation mode. + Bit 1: 1 means enable test mode; 0 means disable test mode. + * Notice * Bit 0 and bit 1 will effect when the DIP Switch setting to program mode. If bit1 is enabled, the bit0 is useless. + Bit 2: Reserved, always 1. + Bit 3: Setting the temperature scale; 0: Fahrenheit, 1:Celsius + Bit 4: Disable illumination report after event triggered. + Bit 5: Disable temperature report after event triggered. + + + Multi-Sensor Function switch. Using bit to control. + Bit 0: Reserved, always 1. + Bit 1: Disable PIR integrate Illumination. + Bit 2: Reserved, always 1. + Bit 3: Reserved. + Bit 4: Reserved. + Bit 5: Reserved. + Bit 6: Enable temperature monitoring. When this bit enabled, the temperature changed 3 degree Fahrenheit, it will report. + And also the temperature over 140 degree Fahrenheit, it will report every 64 seconds. + + + In the security mode, after the PIR report motion detected, setting the re-detect time. 8 seconds per tick, and minimum time is 24 seconds, default tick is 3 (24 seconds). Setting the suitable value to prevent received the trigger signal too frequency. Also can save the battery energy. * Notice * If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not detecting. + + + After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected. 8 seconds per tick, and minimum time is 32 seconds, default tick is 4 (32 seconds). + + + The interval time for auto report the battery level. 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) + + + + The interval time for auto report the illumination. + 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) + + + + The interval time for auto report the temperature. 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) + + + + + + + + + + + + false + + + + + + + + + + diff --git a/openzwave/wenzhou/tz55.xml b/openzwave/wenzhou/tz55.xml new file mode 100644 index 00000000..bb40c99e --- /dev/null +++ b/openzwave/wenzhou/tz55.xml @@ -0,0 +1,45 @@ + + + http://www.openzwave.com/device-database/0118:0004:0003 + images/wenzhou/tz55.png + https://products.z-wavealliance.org/products/1444/ + Smart Plug in Switch + 1. Have Z-Wave controller with exclusion mode + +2. Press the socket on/off button three times within 1.5 seconds to be excluded from the controller + CEPT (Europe) + 1. This plug-in ON/OFF switch in a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. +2. Each socket is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure the signal to ensure that the signal is received by its intended destination. +3. You can use the button in the socket to include/exclude, manually on/off or act as a indicator. You can use it to turn on/off appliance remotely via smart phone or computer. + 1. Press the socket on/off button three times within 1.5 seconds +2. then within 1 second to press and hold on for 5 seconds until the socket button LED is off, reset to factory default successfully +3. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable + + TZ68E + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1444/TZ68G User Manual.pdf + 1. Have Z-Wave controller with inclusion mode + +2. Press the socket on/off button three times within 1.5 seconds to be included to the controller + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1444/xml + + + + + + The LED on the TZ55D will by default, turn ON when the load attached is turned OFF. To make the LED turn ON when the load attached is turned ON instead, set parameter to a value of 1. + + + Stated in the above form,switch by default value is 1,when the value is 0,switch memory function not open; when the value is 1,open switch memory function + + + To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1. + + + The TZ56-D will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the TZ55D is set to flicker for only 1 second. + + + Setting this parameter to the value of 1 will stop the TZ55D from transmitting to devices that are associated into Group 4. + + + diff --git a/openzwave/wenzhou/tz56.xml b/openzwave/wenzhou/tz56.xml new file mode 100644 index 00000000..a5bc4e96 --- /dev/null +++ b/openzwave/wenzhou/tz56.xml @@ -0,0 +1,45 @@ + + + http://www.openzwave.com/device-database/0118:0003:0003 + images/wenzhou/tz56.png + https://products.z-wavealliance.org/products/1586/ + Smart Plug in Switch + 1. Have Z-Wave controller with exclusion mode + +2. Press the socket on/off button three times within 1.5 seconds to be excluded from the controller + CEPT (Europe) + TZ68F + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1586/TZ68 User Manual.pdf + 1. Press the socket on/off button three times within 1.5 seconds +2. then within 1 second to press and hold on for 5 seconds until the socket button LED is off, reset to factory default successfully +3. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable + + 1. Have Z-Wave controller with inclusion mode + +2. Press the socket on/off button three times within 1.5 seconds to be included to the controller + 1. This plug-in ON/OFF switch in a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. +2. Each socket is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure the signal to ensure that the signal is received by its intended destination. +3. You can use the button in the socket to include/exclude, manually on/off or act as a indicator. You can also use it to turn on/off appliances remotely via smart home or computer. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1586/xml + + + + + + The LED on the TZ56D will by default, turn ON when the load attached is turned OFF. To make the LED turn ON when the load attached is turned ON instead, set parameter to a value of 1. + + + Stated in the above form,switch by default value is 1,when the value is 0,switch memory function not open; when the value is 1,open switch memory function + + + To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1. + + + The TZ56-D will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the TZ56D is set to flicker for only 1 second. + + + Setting this parameter to the value of 1 will stop the TZ56D from transmitting to devices that are associated into Group 4. + + + diff --git a/openzwave/wenzhou/tz56s.xml b/openzwave/wenzhou/tz56s.xml new file mode 100644 index 00000000..4a05d5b4 --- /dev/null +++ b/openzwave/wenzhou/tz56s.xml @@ -0,0 +1,33 @@ + + + + + + + The LED on the TZ56S will by default, turn ON when the load attached is turned OFF. To make the LED turn ON when the load attached is turned ON instead, set parameter to a value of 1. + + + Stated in the above form,switch by default value is 1,when the value is 0,switch memory function not open; when the value is 1,open switch memory function + + + To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1. + + + The TZ56-D will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the TZ56S is set to flicker for only 1 second. + + + Setting this parameter to the value of 1 will stop the TZ56S from transmitting to devices that are associated into Group 4. + + + + + + + + + + + diff --git a/openzwave/wenzhou/tz57.xml b/openzwave/wenzhou/tz57.xml new file mode 100644 index 00000000..604077b7 --- /dev/null +++ b/openzwave/wenzhou/tz57.xml @@ -0,0 +1,49 @@ + + + + + + + + The LED on the switch will by default, turn ON when the load attached is turned OFF. + To make the LED turn ON when the load attached is turned ON instead, set parameter to a value of 0. + + + + + + Default with memory: the socket status is same as before when power on + + + + + In the edge mode invert switch + + + + + Led flicker on transmission + + + + + + Enable/Disable group 4 + + + + + + + + + + + + + + + + diff --git a/openzwave/wenzhou/tz65d.xml b/openzwave/wenzhou/tz65d.xml new file mode 100644 index 00000000..787846d3 --- /dev/null +++ b/openzwave/wenzhou/tz65d.xml @@ -0,0 +1,56 @@ + + + http://www.openzwave.com/device-database/0118:0808:0808 + images/wenzhou/tz65d.png + https://products.z-wavealliance.org/products/1362/ + TZ35D + TKB TZ35D Dimmer + CEPT (Europe) + Z-Wave dimmer switch + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1359/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1360/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1361/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1362/xml + + + + + + If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level. If this bit is set to 0, the dimmer will not ignore the start level. + + + Setting this parameter to the value of 1 will stop the TZ66D from transmitting to devices that are associated into Group 4. + + + The LED on the TZ65D will by default, turn ON when the load attached is turned OFF. To make the LED turn ON when the load attached is turned ON instead, set parameter to a value of 1. + + + To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1. + + + The TZ66D can operate shade control devices via its Group 2 if this configuration parameter is set to 1. + + + The TZ66D can operate shade control devices via its Group 3 if this configuration parameter is set to 1. + + + The TZ66-D will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the TZ66D is set to flicker for only 1 second. + + + The TZ66D can operate shade control devices via its Group 3 if this configuration parameter is set to 1. + + + If value is 0, the TZ66D will not poll Group 2. If value is 1, the TZ66D will poll Group 2 at the interval set in Configuration Parameter 20. + + + + + + + + + + + + diff --git a/openzwave/wenzhou/tz66d.xml b/openzwave/wenzhou/tz66d.xml new file mode 100644 index 00000000..a6243168 --- /dev/null +++ b/openzwave/wenzhou/tz66d.xml @@ -0,0 +1,48 @@ + + + http://www.openzwave.com/device-database/0118:1020:0102 + images/wenzhou/tz66d.png + https://products.z-wavealliance.org/products/45/ + The TKB Z-Wave dual wall switch is switching attached loads and is controlled either by the local switching paddle or remotely via the Z-Wave wireless protocol +It is included and controlled in a Z-Wave network by a remote control, a wireless control centre or any other kind of Z-Wave controller including a PC-software. +Beside the local switch the unit can control other Z-Wave units remotely in up to three additional Z-Wave groups, which are associated with this device. Tipping one time or two times the switching paddle performs the control. The left paddle controls the local load while the right paddle remotely controls Z-Wave associated devices only. The association of further Z-Wave devices needs to be done by a Z-Wave controller. The unit is powered by 230V power and needs a pattress box with 230 V power wires for installation. The unit is shipped completely with electronics, switching paddle and mounting frame in white style. It is designed for use within a 3-wire system, which means that a neutral wire is needed for operations. + CEPT (Europe) + http://www.tkbhome.com/guestbook.php + http://www.tkbhome.com/?cn-p-d-170.html + TZ66D + Z-Wave Dual Wall Switch + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/45/xml + + + + + + If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level. If this bit is set to 0, the dimmer will not ignore the start level. + + + Setting this parameter to the value of 1 will stop the TZ66D from transmitting to devices that are associated into Group 4. + + + The LED on the TZ66D will by default, turn ON when the load attached is turned OFF. To make the LED turn ON when the load attached is turned ON instead, set parameter to a value of 1. + + + To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1. + + + The TZ66D can operate shade control devices via its Group 2 if this configuration parameter is set to 1. + + + The TZ66D can operate shade control devices via its Group 3 if this configuration parameter is set to 1. + + + The TZ66-D will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the TZ66D is set to flicker for only 1 second. + + + Defines the poll interval in minutes for group 2 if polling is activated. + + + If value is 0, the TZ66D will not poll Group 2. If value is 1, the TZ66D will poll Group 2 at the interval set in Configuration Parameter 20. + + + diff --git a/openzwave/wenzhou/tz67.xml b/openzwave/wenzhou/tz67.xml new file mode 100644 index 00000000..dc36372a --- /dev/null +++ b/openzwave/wenzhou/tz67.xml @@ -0,0 +1,37 @@ + + + http://www.openzwave.com/device-database/0118:0611:0202 + images/wenzhou/tz67.png + https://products.z-wavealliance.org/products/887/ + http://www.tkbhome.com/guestbook.php + TZ67C + CEPT (Europe) / China + Dimmer Module + FEATURES: +• Provides wireless dimming of lights, and ON/OFF control of lights connected to the Plug-In Lamp Module. +• Plugs directly into wall outlet and provides a switched 230 VAC source. The programming button on the module is also a manual on and off switch. +• Each Plug-In Lamp Module functions as an automatic repeater to other Z-WAVE Modules to ensure full home coverage. + http://www.tkbhome.com/?cn-p-d-149.html + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/36/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/885/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/886/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/887/xml + + + + + + + Defines the behavior of the blue LED. Default: 0 + + + + + + + + + + + diff --git a/openzwave/wenzhou/tz68.xml b/openzwave/wenzhou/tz68.xml new file mode 100644 index 00000000..bb6e680c --- /dev/null +++ b/openzwave/wenzhou/tz68.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/0118:0002:0003 + images/wenzhou/tz68.png + https://products.z-wavealliance.org/products/1952/ + Smart Plug in Switch + 1. Have Z-Wave controller with exclusion mode + +2. Press the socket on/off button three times within 1.5 seconds to be excluded from the controller + 1. Have Z-Wave controller with inclusion mode + +2. Press the socket on/off button three times within 1.5 seconds to be included to the controller + TZ68CN + 1. This plug-in ON/OFF switch in a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. +2. Each socket is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure the signal to ensure that the signal is received by its intended destination. +3. You can use the button in the socket to include/exclude, manually on/off or act as a indicator. You can use it to turn on/off appliance remotely via smart home or computer. + 1. Press the socket on/off button three times within 1.5 seconds +2. then within 1 second to press and hold on for 5 seconds until the socket button LED is off, reset to factory default successfully +3. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1952/TZ68 User Manual.pdf + CEPT (Europe) / Brazil / China + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1423/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1948/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1952/xml + + + + + + + Defines the behavior of the blue LED. + + + + + + + + + + + diff --git a/openzwave/wenzhou/tz69.xml b/openzwave/wenzhou/tz69.xml new file mode 100644 index 00000000..40d40b64 --- /dev/null +++ b/openzwave/wenzhou/tz69.xml @@ -0,0 +1,65 @@ + + + http://www.openzwave.com/device-database/0118:0002:0004 + images/wenzhou/tz69.png + https://products.z-wavealliance.org/products/1950/ + 1. To reset, press the socket on/off button three times within 1.5 seconds +2. then the fourth time, press and hold for seconds until the socket LED is off +3. the socket reset successfully + +Use the "Reset" procedure only in the event that the network primary controller is missing or otherwise inoperable + Smart energy plug in switch + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1950/TZ69PLUS User Manual.pdf + TZ69BR + CEPT (Europe) / China / CEPT (Europe) / Brazil + 1. Enter your Z-Wave controller into inclusion mode +2. Press the socket on/off button three times within 1.5 seconds to be included. + This smart energy plug is able to detect current wattage (5-3000W) and overload wattage (3010-3300W) of connected lights or appliances. When detecting overload state, the switch will be disabled and its on/off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch and it will reset its overload condition to normal status. + 1. Enter your Z-Wave controller into exclusion mode +2. Press the socket on/off button three times within 1.5 seconds to be excluded. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1640/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1665/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1666/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1850/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1886/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1950/xml + + + + + + + + Defines the behavior of the LED. + + + + + + + + + + If the setting is configured for 1 hour (value=720), the TZ69E will report its instant power consumption every 1 hour. + + + If the setting is configured for 1 hour (value=6), the TZ69E will report its accumulated power consumption (kWh) every 1 hour. + + + + + + + + + + + + + + + diff --git a/openzwave/wenzhou/tz74.xml b/openzwave/wenzhou/tz74.xml new file mode 100644 index 00000000..4a047bba --- /dev/null +++ b/openzwave/wenzhou/tz74.xml @@ -0,0 +1,34 @@ + + + + + + + The LED on the TZ74 will by default, turn ON when the load attached is turned OFF. To make the LED turn ON when the load attached is turned ON instead, set parameter to a value of 0. + + + + + switch memory function + + + + + Change the top of the switch to OFF or ON , set parameter 4 to 1. + + + + + switch mode + + + + + + + + + + + + diff --git a/openzwave/wenzhou/tz78.xml b/openzwave/wenzhou/tz78.xml new file mode 100644 index 00000000..a2e20e69 --- /dev/null +++ b/openzwave/wenzhou/tz78.xml @@ -0,0 +1,51 @@ + + + + + images/wenzhou/tz78.png + In Wall Single Relay Switch + 1. Have Z-Wave controller with exclusion mode +2. Press the on/off button three times within 1.5 seconds to be excluded from the controller + 1. Have Z-Wave controller with inclusion mode +2. Press the on/off button three times within 1.5 seconds to be included to the controller + TZ78 + 1. This insert switch module is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. +2. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure the signal to ensure that the signal is received by its intended destination. +3. You can use the button on the switch to include/exclude, manually on/off or act as a indicator. You can use it to turn on/off appliance remotely via smart home or computer. + 1. Press the socket on/off button three times within 1.5 seconds +2. then within 5 second to press and hold on for 1 second until the switch LED is off, reset to factory default successfully +3. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable + + CEPT (Europe) / Brazil / China + + Created, based on TZ74 and TZ68 + Added description, include, exclude, reset info + + + + + + The LED on the TZ78 will by default, turn ON when the load attached is turned OFF. To make the LED turn ON when the load attached is turned ON instead, set parameter to a value of 0. + + + + + switch memory function + + + + + switch mode + + + + + + + + + + + + + diff --git a/openzwave/wenzhou/tz79.xml b/openzwave/wenzhou/tz79.xml new file mode 100644 index 00000000..0df0bf35 --- /dev/null +++ b/openzwave/wenzhou/tz79.xml @@ -0,0 +1,46 @@ + + + + + + + Defines the behavior of the LED. + + + + + + + + + + If the setting is configured for 1 hour (value=720), the TZ79 will report its instant power consumption every 1 hour. + + + If the setting is configured for 1 hour (value=6), the TZ79 will report its accumulated power consumption (kWh) every 1 hour. + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/wenzhou/tz88.xml b/openzwave/wenzhou/tz88.xml new file mode 100644 index 00000000..38059539 --- /dev/null +++ b/openzwave/wenzhou/tz88.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/0118:0001:0001 + images/wenzhou/tz88.png + https://products.z-wavealliance.org/products/883/ + http://www.tkbhome.com/?cn-p-d-259.html + This plug-in ON/OFF switch TZ88 is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus™ enabled devices displaying the Z-Wave Plus™ logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-Wave™ enabled networks. Remote On/Off control of the connected load is possible with other manufacturer’s wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because TZ88 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. +This plug-in ON/OFF switch is able to detect instance wattage (3000W/CE/CN, 1500W/UL/TW/JP) and overload current (14.5A) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status. + + Smart Energy Plug In Switch + TZ88U + CEPT (Europe) / U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/785/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/786/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/787/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/883/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1324/xml + + https://products.z-wavealliance.org/products/1324/ + Use this procedure only in the event that the primary controller is lost or otherwise inoperable. +1. Pressing On/Off button three times within 2 seconds will enter inclusion mode. +2. Within 1 second, press On/Off button again for 5 seconds until LED is off. +3. IDs are excluded. + 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. +2. Pressing On/Off button three times within 2 seconds will enter inclusion mode. + CEPT (Europe) + 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. +2.Pressing On/Off button three times within 2 seconds will enter exclusion mode. +3. Node ID has been excluded. + TZ88 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1324/TKB TZ88 manual-20150527.pdf + + + + + + If the setting is configured for 1 hour (value=720), the TZ88 will report its instant power consumption every 1 hour. + + + If the setting is configured for 1 hour (value=6), the TZ88 will report its accumulated power consumption (kWh) every 1 hour. + + + diff --git a/openzwave/widom/DRY.xml b/openzwave/widom/DRY.xml new file mode 100644 index 00000000..40bc092e --- /dev/null +++ b/openzwave/widom/DRY.xml @@ -0,0 +1,118 @@ + + + https://www.widom.it/it/smart-dry-contact-switch/ + images/widom/DRY.png + https://www.widom.it/wp-content/uploads/2019/03/Widom_Dry_Contact_EN.pdf + DRY + WiDOM Smart Dry Contact + WiDOM Smart Dry Contact is an ON\\OFF device based on latching relay and can be used as both a local and remote switch. + CEPT (Europe) + + Initial Metadata + Added product image + + + + + + + + Defines which sequences of clicks on the external switch control the load + 0 - Local Control disabled + 1 - 1 click controls the local load + 2 - 2 clicks control the local load + 4 - 3 clicks control the local load + 7 - The load connected to the Channel 1 can be controlled using 1 click, 2 clicks or 3 clicks + Default value: 7 + Other options: + To control the load with 1 click and 2 clicks -> Parameter value must be 1 + 2 =3 + To control the load with 1 click and 3 clicks -> Parameter value must be 1 + 4 =5 + To control the load with 2 clicks and 3 clicks -> Parameter value must be 2 + 4 =6 + + + + Value used for devices belonging to Group 2 when the external switch receives 1 Click + 1-99 : Dimming purpose + 0 : OFF + -1 : ON + 100 : (Default Value) The same value of dry contact status + + + + Value used for devices belonging to Group 3 when the external switch receives 2 + 1-99 : Dimming purpose + 0 : OFF + -1 : ON + 100 : (Default Value) The same value of dry contact status + + + + Value used for devices belonging to Group 4 when external switch receives 3 Clicks + 1-99 : Dimming purpose + 0 : OFF + -1 : ON + 100 : (Default Value) The same value of dry contact status + + + + Defines the time after which the relay is switched OFF + 1 - 32000 : Number of time units (see parameter No.15) after which the dry contact is switched OFF + 0 : (Default Value) Timer disabled + + + + Defines the time after which the relay is switched ON + 1 - 32000 : Number of time units (see parameter No.15) after which the dry contact is switched ON + 0 : (Default Value) Timer disabled + + + + Defines the time unit used for parameters No.10 and No.11. (Default Value: 1 ) + + + + + + Defines the Scene Activation Set value sent to the Lifeline group with 1 Click on the external switch (Default Value: 0 ) + 1 - 255 : Value sent to the Lifeline group + 0 : (Default Value) No value is sent + + + + + Defines the Scene Activation Set value sent to the Lifeline group with 2 Clicks on the external switch (Default Value: 0 ) + 1 - 255 : Value sent to the Lifeline group + 0 : (Default Value) No value is sent + + + + + Defines the Scene Activation Set value sent to the Lifeline group with 3 Clicks on the external switch (Default Value: 0 ) + 1 - 255 : Value sent to the Lifeline group + 0 : (Default Value) No value is sent + + + + + Defines the status of the device following a restart (Default Value: 3 ) + + + + + + Defines the type of external switch connected to the device (Default Value: 1 ) + + + + + + + + + + + + + + + diff --git a/openzwave/widom/UBS104.xml b/openzwave/widom/UBS104.xml new file mode 100644 index 00000000..92b4e6b4 --- /dev/null +++ b/openzwave/widom/UBS104.xml @@ -0,0 +1,260 @@ + + + http://www.openzwave.com/device-database/0149:0104:0012 + images/widom/UBS104.png + https://products.z-wavealliance.org/products/1016/ + UBS104 + WiDOM Universal Relay Switch UBS104 + WiDOM Universal Relay Switch is an ON\\OFF device based on latching relay and can be used as both a local and remote switch. + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1016/xml + + + + + + + + Device status when the external switch receives 1 click + + + + + + + Device status when the external switch receives 2 clicks + + + + + + + Device status when the external switch receives 3 clicks + + + + + + + Device status when the external switch is held down + + + + + + + Action on the associated devices when the external switch receives 1 click" + + + + + + + + + Action on the associated devices when the external switch receives 2 clicks + + + + + + + + + Action on the associated devices when the external switch receives 3 clicks + + + + + + + + + Action on the associated devices when the external switch is held down + + + + + + + + + Action performed on all network devices when the external switch receives 1 click + + + + + + + + Action performed on all network devices when the external switch receives 2 clicks + + + + + + + + Action performed on all network devices when the external switch receives 3 clicks + + + + + + + + Action performed on all network devices when the external switch is held down + + + + + + + + Device status upon receipt of a Basic Set + + + + + + + ON_LEVEL value used for devices belonging to Group 2 (1 Click association group). Set value from 0 to 255 (Default: 255) + + + OFF_LEVEL value used for devices belonging to Group 2 (1 Click association group). Set value from 0 to 255 (Default: 0) + + + ON_LEVEL value used for devices belonging to Group 3 (2 Click association group). Set value from 0 to 255 (Default: 255) + + + OFF_LEVEL value used for devices belonging to Group 3 (2 Click association group). Set value from 0 to 255 (Default: 0) + + + ON_LEVEL value used for devices belonging to Group 4 (3 Click association group). Set value from 0 to 255 (Default: 255) + + + OFF_LEVEL value used for devices belonging to Group 4 (3 Click association group). Set value from 0 to 255 (Default: 0) + + + ON_LEVEL value used for devices belonging to Group 5 (Hold association group). Set value from 0 to 255 (Default: 255) + + + OFF_LEVEL value used for devices belonging to Group 5 (Hold association group). Set value from 0 to 255 (Default: 0) + + + Timer associated with the 1 click event on the external switch + + + + + Timer associated with the 2 click event on the external switch + + + + + Timer associated with the 3 click event on the external switch + + + + + Timer associated with the hold event on the external switch + + + + + Timer associated with the reception of a Basic Set command + + + + + Time in seconds (1 3600). Default: 600 (10 minutes) + + + Switch-off timer validity + + + + + Smoke Alarm, CO, CO2 Action + + + + + + + Heat Allarm + + + + + + + Water Allarm + + + + + + + Home Security + + + + + + + ON time during flashing. Set value from 0 to 255 (Default: 5) + + + OFF time during flashing. Set value from 0 to 255 (Default: 5) + + + Duration of flashing phase. Set value from 0 to 255 (Default: 10) + + + Startup Status + + + + + + Configuration Reset + + + + + + + Type of external switch + + + + + + + + Sensitivity. Set value from 0 to 255 (Default: 9) + + + Load protection. Time in seconds (3600). Default: 0 + + + Learn Mode + + + + + + + + + + + + + + + + + diff --git a/openzwave/widom/UME304C_S.xml b/openzwave/widom/UME304C_S.xml new file mode 100644 index 00000000..5c59f020 --- /dev/null +++ b/openzwave/widom/UME304C_S.xml @@ -0,0 +1,199 @@ + + + http://www.openzwave.com/device-database/0149:0304:1214 + images/widom/UME304C_S.png + https://products.z-wavealliance.org/products/1283/ + Press the push button (B) located on the top of the device six consecutive times within one minute from system start-up. Please use this procedure only in the event that the primary controller is missing or otherwise inoperable. + The smallest device in its category worldwide, and the only device specifically intended for use both as a Relay Switch with integrated power meter, and as an Energy Meter either at the point of entry of your electrical system, or on a section of the latter. Available in two versions, version S featuring an internal shunt resistor, and version C featuring an external current transformer, it is capable of measuring loads exceeding 10 KW. In addition to Power measurements, the device also provides data for Energy, Voltage, Current and Power factor. +The only device suited for use with all types of Z-Wave controller, and capable of implementing an active energy-saving management policy defined by the user according to his energy consumption, or to the amount of energy produced by his solar power system. It automatically connects and disconnects a specific load if the threshold limit is exceeded, or “supplies” the required power, momentarily excluding non-priority loads. +Main Feature: +• Active Energy-saving Management +• Control and monitoring of usage +• Control and monitoring of production and net metering +• Monitoring of all network parameters (Power, Energy, Voltage, Current, Power Factor) +• Provides bidirectional measurements for Power and Energy (produced/consumed). +• Management and prevention of electrical faults +• Intelligent Opening/Closing of the Relay +• Control of heavy loads +• Software Update +• Extremely low energy usage + 1. Put your system controller into inclusion mode by following the instructions provided by your controller manufacturer. +2. Press the push button (B) located on the top of the device once." + + 1. Put your system controller into exclusion mode by following the instructions provided by your controller manufacturer. +2. Press the push button (B) located on the top of the device three time." + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1283/WiDom Energy Driven Switch - EN.pdf + Energy Driven Switch Version S + WPM1.04C + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1264/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1283/xml + + + + + + + + Device status when the external switch receives 1 click + + + + + + + Device status when ZWave command Basic Set is received + + + + + + + C VERSION. Sets the current level above which the time spent above that level is measured. For S VERSION. Sets to 1250 the default and max current level above which the time spent above that level is measured (Hundredths of Amperes) + + + Sets the time beyond which, in the case of overcurrent at a level higher than that established in parameter 30, an OverCurrent event occurs (seconds) + + + Defines the next state of the device if an overcurrent event has occurred. + + + + + + + Provides total operating time from last meter reset. When set to 0 it resets the cumulated values of energy and total operating time. + + + Determines whether energy events are related to energy consumed or energy produced + + + + + C VERSION. Sets the level of instantaneous power in Watts beyond which time of permanence above this level is calculated. For S VERSION. Sets to 3000 the default and max level of instantaneous power in Watts beyond which time of permanence above this level is calculated. + + + Sets the time in seconds beyond which, if instantaneous power remains at levels exceeding threshold defined by parameter 35, a UP Power event occurs. + + + Defines the next state of the device if an overcurrent event has occurred. + + + + + + + Defines the status of associated devices in the presence of a UP Power event. From: 1 to 99 for dimming purpose. .0 (OFF) and -1(ON) for switching ON/OFF + + + Sets the level of instantaneous power in Watts beyond which time of permanence below this level is calculated. + + + Sets the time in seconds beyond which, if instantaneous power remains at levels below threshold defined by parameter 39, a DOWN Power event occurs. + + + Defines the next state of the device in the case of a DOWN Power event occurring. + + + + + + + Defines the status of associated devices in the presence of a DOWN Power event. From: 1 to 99 for dimming purpose. 0 (OFF) and -1(ON) for switching ON/OFF. + + + the energy level that once exceeded an Energy Limit event occurs. From 0 to 2.000.000 KWh Default value: 2.000.000 KWh + + + Defines the next state of the device in the case of an Energy Limit event occurs + + + + + + + Defines the percentage variation of instantaneous power determining the sending of the report.(Default: 10%) + + + Defines the maximum time in minutes since the previous report beyond which an Instantaneous Power Report will still be sent. (Default: 10 minutes) + + + Defines the increase of total energy required to generate a report listing the level of total energy to the devices associated to the Energy Notification Group. + + + + + + + + Defines the nominal voltage value in tenths of volts. Together with parameter No. 49 this is used by the automatic notification system to send reports on variations of voltage. + + + Defines, as a percentage, the nominal value for permitted fall in maximum voltage.(default 10%) + + + + Defines which electric parameters, other than power, will be subjected to automatic notification. The value to be set for this parameter must be calculated as the sum of values associated to the individual electric parameter indicated in the table.(default 30) + Byte 1 : Bit 7: reserved; + Bit 6:reserved; + Bit 5: Multilevel Sensor: Power Report; + Bit 4: Power factor; + Bit 3: Current; + Bit 2: Voltage; + Bit 1: Energy; + Bit 0: Power; + + + + Returns the value of voltage RMS at the time of the reading expressed in tenths of Volts.. + + + Returns the value of current RMS expressed in hundredths of Amperes. + + + Returns the value of power factor as a percentage. + + + Returns the value of total energy consumed expressed in Wh (thousandths of KWh). + + + Returns the value of total energy produced expressed in Wh (thousandths of KWh). + + + Defines the status of the device following a restart(default 3) + + + + + + Defines which parameters should be reset to default values.(default 4) + + + + + + + Defines the type of external switch connected to the device.(default 4) + + + + + + + Defines the load control mode.(default 1) + + + + + + + + + + + + + + + diff --git a/openzwave/widom/UMS2.xml b/openzwave/widom/UMS2.xml new file mode 100644 index 00000000..36c7f39a --- /dev/null +++ b/openzwave/widom/UMS2.xml @@ -0,0 +1,128 @@ + + + https://www.widom.it/en/smart-roller-shutter/ + images/widom/UMS2.png + https://www.widom.it/wp-content/uploads/2019/03/Widom_Smart_Roller_Shutter_EN_0.pdf + UMS2 + WiDOM Smart Roller Shutter + WiDom Smart Roller Shutter is an "in wall device", for the multilevel control of roller shutter motors. + It can accurately control the opening and closing of blinds, curtains, shutters, venetian blinds as requested by the user through local commands or remotely + using computers, smartphones, tablets. + CEPT (Europe) + + Initial Metadata + Some fixes comparing with openHab exported file + Added product image + + + + + + + Define which sequences of click control the local load. (Default Value: 3) + + + + + + + + 50 to 100: 50-100% opening level (100% correspond to completely open) + (Default Value: 100) + + + + + 0 to 49: 0-49% opening level (0 correspond to completely closed) + (Default Value: 0) + + + + + Value used for devices belonging to Group 2 when UP button receive 1 Click + 1-99 : Dimming purpose + 0 : OFF + -1 : ON (Default Value) + + + + + Value used for devices belonging to Group 2 when DOWN button receive 1 Click + 1-99 : Dimming purpose + 0 : OFF (Default Value) + -1 : ON + + + + + Value used for devices belonging to Group 3 when UP button receive 2 Clicks + 1-99 : Dimming purpose + 0 : OFF + -1 : ON (Default Value) + + + + + Value used for devices belonging to Group 3 when DOWN button receive 2 Clicks + 1-99 : Dimming purpose + 0 : OFF (Default Value) + -1 : ON + + + + + Value used for devices belonging to Group 4 when UP button receive 3 Clicks + 1-99 : Dimming purpose + 0 : OFF + -1 : ON (Default Value) + + + + + Value used for devices belonging to Group 4 when DOWN button receive 3 Clicks + 1-99 : Dimming purpose + 0 : OFF (Default Value) + -1 : ON + + + + + Defines the status of the calibration procedure. By default, as soon as the device has been included, the + calibration starts in automatic mode. At the end of the calibration, this parameter is set to 1. + Afterwards the calibration can be done again by setting this parameter to 0 (AUTO) or 2 (MANUAL) and clicking + on any external button. If the calibration is set in AUTO mode, it will be completed automatically. + If the calibration is set in MANUAL mode, a click on any external button is necessary to carry on the next step. + During the calibration, the LED indicator blinks repeatedly in BLUE. + (Default Value: 0) + + + + + + + + Defines the level of power consumption under which the motor is considered steady (stationary) + 0 to 3000 : Expressed in hundredths of Watt (ex. 3000=30 Watt) + (Default Value: 1000) + + + + + The motor has reached the limit switch when its power consumption is lower than PLIMIT (the power defined in parameter No. 21) for an amount of time defined by this parameter. + 1 to 127 : Expressed in hundredths of Watt (ex. 3000=30 Watt) + 0 : Limit Switch ignored + (Default Value: 30) + + + + + + + + + + + + + + diff --git a/openzwave/widom/WDS.xml b/openzwave/widom/WDS.xml new file mode 100644 index 00000000..0906e421 --- /dev/null +++ b/openzwave/widom/WDS.xml @@ -0,0 +1,163 @@ + + + http://www.openzwave.com/device-database/0149:0504:1214 + images/widom/WDS.png + https://products.z-wavealliance.org/products/1569/ + 0504 + Only a controller can remove a device from the network. WiDom Universal Double Switch is compatible with all Z-Wave certified controllers. After the exclusion procedure has been activated by the controller, the device can be removed, putting it in Exclusion Mode by three consecutive clicks on the (B) button or on the external switch, when available. + The device can be reset ot the factory reset by six consecutive clicks. This procedure shuld be used only if the primary controller is missing or inoperable. + If the device is not included into a Z-Wave network, a single click on the (B) button or on one of the external switches will launch the process of traditional inclusion. If the device inclusion procedure does not start within 2 seconds, the Network Wide Inclusion network will be launched lasting a variable amount of time between 15-30 seconds. + Universal Double Switch is the ON/OFF smallest control device in the world designed to independently control two separate loads, suited for use as both a local and remote switch. Similarly to the other WiDom “in wall” devices, it can be fully integrated into pre-existing systems and configured to associate configurable behaviours to a specific number of clicks, in full integration with the Z-Wave home automation ecosystem. +Each of its two channels features an integrated consumption measurement device. The Universal Double Switch also boasts the lowest energy consumption on the market. +At the same time, it is completely configurable so that it can adapt to the most varied needs while also being ready to be used without needing additional configurations in order to operate. +Thanks to the framework developed by WiDom, the various types of “events” on the “External Switch” can be recognised and associated to actions to be performed on the device, on any associated devices, on all devices on the network. + CEPT (Europe) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1569/Widom Double Relay_EN.pdf + WDS + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1569/xml + + + + + + Defines the status of the output O1/O2 when the switch connected to I1/I2 receives 1 Click + + + + + + + + Defines the status of the output O1/O2 when the switch connected to I1/I2 receives 2 Click + + + + + + + + Defines if the outputs are controlled individually, as a traditional device with two channels, or if its behaviour simulates a single pole double throw relay. + 0 - SINGLE CHANNELS (Default Value) => Channel 1 and Channel 2 are controlled individually. + From 1 to 9 - SINGLE POLE DOUBLE THROW RELAY => The two channels are in opposite status. If the Channel 1 is close the Channel 2 is open, if the Channel 1 is open the Channel 2 is close. The value of the parameter defines the closing delay of the relay in tenth of seconds + From 10 to 19 - SEQUENCING RELAY => Channels are toggled in this way: both channels ON, only channel 1 ON, only channel 2 ON, both channels OFF. The value of the parameter, deducted of 9, defines the closing delay of the relay in tenth of seconds. + From 20 to 39 - SELECTOR => Both channels can be OFF but they can never be ON simultaneously. It can be used for fan coil control, roller shutters, and in general for two-speed systems. The value of the parameter, deducted of 19, defines the closing delay of the relay in tenth of seconds. + + + + This parameter allows to choose operating for the 1st channel controlled by the S1 switch. + + + + + + 0 - SWITCH_OFF The associated devices are switched OFF. + -1 - SWITCH_ON The associated devices are switched ON. + From 1 to 99 The associated devices (dimmer, roller shutters) are set to the indicated level (only for devices associated to group 3). + 100 - RELAY_STATUS (Default Value) If the Relay 1 is ON/OFF, the associated devices are ON/OFF. + 101 - RELAY_STATUS_BUT_IGNORE_IF_OFF If the Relay 1 is ON the associated devices are ON; if it is OFF no action is taken on the associated devices. + 102 - RELAY_STATUS_BUT_IGNORE_IF_ON If the Relay 1 is OFF the associated devices are OFF; if it is ON no action is taken on the associated devices. + 103 - RELAY_OPPOSITE_BUT_IGNORE_IF_OFF If the Relay 1 is ON the associated devices are OFF; if it is OFF no action is taken on the associated devices. + 104 - RELAY_OPPOSITE_BUT_IGNORE_IF_ON If the Relay 1 is OFF the associated devices are ON; if it is ON no action is taken on the associated devices. + 105 - RELAY_OPPOSITE If the Relay 1 is ON/OFF, the associated devices are OFF/ON. + 106 - IGNORE No action is taken on the associated devices. + + + + + 0 - SWITCH_OFF The associated devices are switched OFF. + -1 - SWITCH_ON The associated devices are switched ON. + From 1 to 99 The associated devices (dimmer, roller shutters) are set to the indicated level (only for devices associated to group 5). + 100 - RELAY_STATUS (Default Value) If the Relay 2 is ON/OFF, the associated devices are ON/OFF. + 101 - RELAY_STATUS_BUT_IGNORE_IF_OFF If the Relay 2 is ON the associated devices are ON; if it is OFF no action is taken on the associated devices. + 102 - RELAY_STATUS_BUT_IGNORE_IF_ON If the Relay 2 is OFF the associated devices are OFF; if it is ON no action is taken on the associated devices. + 103 - RELAY_OPPOSITE_BUT_IGNORE_IF_OFF If the Relay 2 is ON the associated devices are OFF; if it is OFF no action is taken on the associated devices. + 104 - RELAY_OPPOSITE_BUT_IGNORE_IF_ON If the Relay 2 is OFF the associated devices are ON; if it is ON no action is taken on the associated devices. + 105 - RELAY_OPPOSITE If the Relay 2 is ON/OFF, the associated devices are OFF/ON. + 106 - IGNORE No action is taken on the associated devices. + + + + + Defines the time after which the Channel 1 is switched OFF. + 0 (Default Value) Timer disabled. + From 1 to 32000 (seconds) After this time the relay of the Channel 1 is OFF. + + + + + Defines the time after which the Channel 2 is switched OFF. + 0 (Default Value) Timer disabled. + From 1 to 32000 (seconds) After this time the relay of the Channel 1 is OFF. + + + + + Defines the time after which the Channel 1 is switched ON. + 0 (Default Value) Timer disabled. + From 1 to 32000 (seconds) After this time the relay of the Channel 1 is ON. + + + + + Defines the time after which the Channel 2 is switched ON. + 0 (Default Value) Timer disabled. + From 1 to 32000 (seconds) After this time the relay of the Channel 1 is ON. + + + + The two channels can be controlled individually by Z-Wave network. + The status of the channels upon receipt of a Multi-Channel Basic Set command is defined by the value set on the parameter. + + + + + + + + The channels of the device can be controlled individually from all other Z-Wave devices that support the multichannel feature. + In order to support also the integration with no-multichannel systems, this parameter allows to define if the receipt of a no-multichannel command controls only the Channel 1 or both. + + + + + + Defines the status of the device following a restart. + + + + + + + + Defines which parameters should be reset to default values. + + + + + + + + Defines the type of external switch connected to the device. + + + + + + + + + true + + + + + + + + + + + + + diff --git a/openzwave/widom/WDS2.xml b/openzwave/widom/WDS2.xml new file mode 100644 index 00000000..81ff81d0 --- /dev/null +++ b/openzwave/widom/WDS2.xml @@ -0,0 +1,189 @@ + + + https://www.widom.it/it/smart-double-switch/ + images/widom/WDS2.png + WDS2 + Widom Smart Double Switch is the new ON/OFF smallest control device in the world designed to independently control two separate loads + CEPT (Europe) + https://www.widom.it/wp-content/uploads/2019/03/Widom_Smart_Double_Switch_EN.pdf + WiDom Smart Double switch + + Initial Metadata + Some fixes comparing with openHab exported file + Added product image + + + + + + + Define which sequences of clicks control the load connected to both Channel 1 and Channel 2, if parameter No. 2 is set to its default value. + Otherwise parameter No.1 sets the clicks sequence only for Channel 1 and parameter No. 2 sets the clicks sequence for Channel 2. + 0 - Local Control disabled + 1 - 1 click controls the local load + 2 - 2 clicks control the local load + 4 - 3 clicks control the local load + 7 - The load connected to the Channel 1 can be controlled using 1 click, 2 clicks or 3 clicks + Default value: 7 + Other options: + To control the load with 1 click and 2 clicks -> Parameter value must be 1 + 2 =3 + To control the load with 1 click and 3 clicks -> Parameter value must be 1 + 4 =5 + To control the load with 2 clicks and 3 clicks -> Parameter value must be 2 + 4 =6 + + + + + Defines which sequences of click control the load connected to Channel 2 + 0 - Local Control disabled + 1 - 1 click controls the local load + 2 - 2 clicks control the local load + 4 - 3 clicks control the local load + 8 - The load connected to the Channel 2 will be controlled with the same number of clicks configured for Channel 1 load. + Default value: 8 + Other options: + To control the load with 1 click and 2 clicks -> Parameter value must be 1 + 2 =3 + To control the load with 1 click and 3 clicks -> Parameter value must be 1 + 4 =5 + To control the load with 2 clicks and 3 clicks -> Parameter value must be 2 + 4 =6 + To control the load with 1 click, 2 clicks and 3 clicks -> Parameter value must be 1 + 2 + 4 =7 + + + + + Value used for devices belonging to Group 2 when external switch I1 receives 1 Click + 1-99 : Dimming purpose + 0 : OFF + -1 : ON + 100 : (Default Value) The same value of Channel 1 load status + + + + + Value used for devices belonging to Group 5 when external switch I2 receives 1 Click + 1-99 : Dimming purpose + 0 : OFF + -1 : ON + 100 : (Default Value) The same value of Channel 2 load status + + + + + Value used for devices belonging to Group 3 when external switch I1 receives 2 Clicks + 1-99 : Dimming purpose + 0 : OFF + -1 : ON + 100 : (Default Value) The same value of Channel 1 load status + + + + Value used for devices belonging to Group 6 when external switch I2 receives 2 Clicks + 1-99 : Dimming purpose + 0 : OFF + -1 : ON + 100 : (Default Value) The same value of Channel 2 load status + + + + + Value used for devices belonging to Group 4 when external switch I1 receives 3 Clicks + 1-99 : Dimming purpose + 0 : OFF + -1 : ON + 100 : (Default Value) The same value of Channel 1 load status + + + + + Value used for devices belonging to Group 7 when external switch I2 receives 3 Clicks + 1-99 : Dimming purpose + 0 : OFF + -1 : ON + 100 : (Default Value) The same value of Channel 2 load status + + + + + Defines the time after which the Channel 1 load is switched OFF. + 0 (Default Value) Timer disabled. + From 1 to 32000 (seconds) After this time the relay of the Channel 1 is OFF. + + + + + Defines the time after which the Channel 2 load is switched OFF. + 0 (Default Value) Timer disabled. + From 1 to 32000 (seconds) After this time the relay of the Channel 2 is OFF. + + + + + Defines the time after which the Channel 1 load is switched ON. + 0 (Default Value) Timer disabled. + From 1 to 32000 (seconds) After this time the relay of the Channel 1 is ON. + + + + + Defines the time after which the Channel 2 load is switched ON. + 0 (Default Value) Timer disabled. + From 1 to 32000 (seconds) After this time the relay of the Channel 2 is ON. + + + + + Defines the behavior of the device Channels when the I1/I2 external switches receive a valid number of clicks (see Parameters No. 1 and No. 2). + Note: When to the parameter 40 is given a value different from zero, the associated devices will not be controlled. + + + + + + + Defines the status of the device following a restart (Default Value: 4). + + + + + + + + + Defines the type of external switch connected both to input 1 and input 2, if parameter No. 63 is set in its default value. + Otherwise parameter No. 62 defines only the external switch connected to the input 1 and parameter No. 63 the switch connected to the input 2. + (Default Value: 1) + + + + + + + + Defines the type of external switch connected both to input 1 and input 2, if parameter No. 63 is set in its default value. + Otherwise parameter No. 62 defines only the external switch connected to the input 1 and parameter No. 63 the switch connected to the input 2. + (Default Value: 1) + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/widom/WSP.xml b/openzwave/widom/WSP.xml new file mode 100644 index 00000000..1bfb684f --- /dev/null +++ b/openzwave/widom/WSP.xml @@ -0,0 +1,118 @@ + + + https://www.widom.it/it/smart-plug/ + images/widom/WSP.png + https://www.widom.it/wp-content/uploads/2019/08/Widom-Smart-Plug_EN_20190404_0.pdf + WSP + WiDOM Smart Dry Contact + WiDom Smart Plug is able to detect overvoltage and/or overcurrent events and indicate them through a + multicolor LED. Furthermore, it protects appliances from eventual overload. A very innovative design, which + integrates a complex system that allows a precise energy consumption monitoring. The integration of these + features in its very small size product, make it unique on the market. + CEPT (Europe) + + Initial Metadata + Initial Metadata + Added product image + + + + + + + Defines which sequences of click control the local load + + + + + + + Defines how to control the devices associated to 1 click event + 1-99 : The associated devices (dimmer, roller shutters) are set to the indicated level + 0 : OFF + -1 : ON + 100 : (Default Value) If the relay is ON/OFF, the associated devices are ON/OFF + + + + + Defines how to control the devices associated to 2 clicks event + 1-99 : The associated devices (dimmer, roller shutters) are set to the indicated level + 0 : OFF + -1 : ON + 100 : (Default Value) If the relay is ON/OFF, the associated devices are ON/OFF + + + + + Defines the voltage level (in Volts) beyond which an overvoltage event is identified and the overvoltage timer is activated. + The timer is reset when the event ceases, i.e. when the voltage returns below the overvoltage level. + As soon as an overvoltage event occurs, the LED starts a BLUE blinking. + If the overvoltage event ceases before the overvoltage timer expires, the blue blinking is stopped, + otherwise the alarm is generated and the blinking reset is established by parameter 6. + (Default value: 253) + + + + + Define the time (seconds) in which the voltage must persist above the overvoltage level so that an alarm is generated. + 1 - 36000: Overvoltage time interval (in seconds) after witch an alarm is generated + (Default Value: 5) + + + + Define how to reset the overvoltage alarm and breaks off the blue blinking. + + + + + + Define how to control the devices associated to the overvoltage alarm + 1-99 : The associated devices (dimmer, roller shutters) are set to the indicated level + 0 : OFF (Default Value) + -1 : ON + + + + + Defines the current level (in Amps) beyond which an overcurrent event is identified and the overcurrent timer is activated. + The timer is reset when the event ceases, i.e. when the current returns below the overcurrent level. + As soon as an overcurrent event occurs, the LED starts a GREEN blinking. + If the overcurrent event ceases before the overcurrent timer expires, the GREEN + 1 - 12 : Defines the overcurrent level (in Amps) + (Default Value: 12 ) + + + + + Define the time (seconds) in which the current must persist above the overcurrent level so that an alarm is generated and the relay is opened. + 1 - 36000: Overcurrent time interval (in seconds) after witch an alarm is generated + (Default Value: 10) + + + + Define how to reset the over-current alarm and breaks off the red blinking. + + + + + + Define how to control the devices associated to the overcurrent alarm + 1-99 : The associated devices (dimmer, roller shutters) are set to the indicated level + 0 : OFF (Default Value) + -1 : ON + + + + + + + + + + + + + + + diff --git a/openzwave/widom/WTED.xml b/openzwave/widom/WTED.xml new file mode 100644 index 00000000..f376f753 --- /dev/null +++ b/openzwave/widom/WTED.xml @@ -0,0 +1,86 @@ + + + https://www.widom.it/it/smart-dimmer/ + images/widom/WTED.png + https://www.widom.it/wp-content/uploads/2019/01/Widom_Smart_Dimmer_EN_1.pdf + WTED + WiDOM Smart TE Drimmer + WiDom Smart TE Dimmer is an "in-wall device" that controls the luminosity level and/or fan speed. + A universal device that controls the light intensity of all types of dimmable lights, including LED lamps and energy-saving lamps. + The Smart TE Dimmer includes the ON / OFF control option of non-dimmable loads + CEPT (Europe) + + Initial Metadata + Some fixes comparing with openHab exported file + Added product image + + + + + + + + Defines the status of the device, in term of light level, following a restart. + 0-99: 0-99% dimming level after device restart + -1: (Defaukt Value) At device’s restart it restores the same dimming level at the moment of power failure. + + + + + Defines the time spent to switch the load from complete OFF to complete ON. + 1 to 127 : Expresses in seconds the time spent to switch the load from complete OFF to complete ON + -1 to -126: Expresses in minutes the time spent to switch the load from complete OFF to complete ON + (Default Value: 1) + + + + + Defines the time spent to switch the load from complete ON to complete OFF. + 1 to 127 : Expresses in seconds the time spent to switch the load from complete ON to complete OFF. + -1 to -126: Expresses in minutes the time spent to switch the load from complete ON to complete OFF. + (Default Value: 1) + + + + + Defines the time spent to switch the controlled load when the external switch is hold down. + 0: Applies the timing spent to switch the controlled load to Fade On and Fade Off as defined in parameters 2 and 3. + 1-60: Expresses in seconds the time spent to switch the load. + (Default value: 5) + + + + + Defines the light level that will correspond to the 1% of dimming. + 1 to 98: Defines which light level will correspond to 1% in the range between 1 and 98% + (Default Value: 1) + + + + + Defines the light level that will correspond to the 99% of dimming. + 2 to 99: Defines which light level will correspond to 99% in the range between 2 and 99% + (Default Value: 99) + + + + Define how to reset the overvoltage alarm and breaks off the blue blinking. (Defaukt Value: 1) + + + + + Defines the type of external switch connected to the device (Default Value: 1 ) + + + + + + + + + + + + + diff --git a/openzwave/wink/wnk-mot1.xml b/openzwave/wink/wnk-mot1.xml new file mode 100644 index 00000000..2fe6e04d --- /dev/null +++ b/openzwave/wink/wnk-mot1.xml @@ -0,0 +1,84 @@ + + + + Motion Sensor + Battery powered Z-Wave Plus motion sensor + http://www.openzwave.com/device-database/017F:0001:0101 + https://www.wink.com/products/wink-motion-sensor/ + https://www.wink.com/help/products/ + images/wink/wnk-mot1.png + + + 1. Bring the sensor within range of your controller. + 2. If the devices is new, remove the pull tab. Otherwise remove, then replace the battery. + The LED will flash 5 times to indicate inclusion. + + 1. Remove the sensor cover by twisting counter clockwise. + 2. Press the connect button (next to the battery) 3 times. + The LED will flash 5 times to indicate exclustion. + + + 1. Remove the sensor cover by twisting counter clockwise. + 2. Hold the connect button (next to the battery) for 10 seconds until the LED blinks. + + https://products.z-wavealliance.org/products/2482 + U.S. / Canada / Mexico + WNK-MOT1 + + Initial information based on Z-Wave alliance database information + + + + + + + Motion sensor sensitivity Level. Valid values 8 to 255. + + + Valid values 5 to 600 seconds (10 mins). + + + 0: Turn Off + 1 to 99: Dim Level + 255: On + + + + On = Enable Motion Detection. + + + Ambient Light Threshold for the Group 2 Association trigger. Vaid values 5 to 1000 lux. + + + Prevent retriggering within the specified time period. Valid values 1 to 8 seconds. + + + Valid values 60 to 3600 seconds. + + + On = Enable the Ambient Light Threshold when using the Group 2 Association. + + + Valid values 0 to 255 lux. + + + On = Enable the LED Indicator. + + + + + + + false + + + + + + + + + + + + diff --git a/openzwave/wink/wnk-sir1p.xml b/openzwave/wink/wnk-sir1p.xml new file mode 100644 index 00000000..b5b7e323 --- /dev/null +++ b/openzwave/wink/wnk-sir1p.xml @@ -0,0 +1,89 @@ + + + + Siren + Battery-powered alarm, chime, and flash + http://www.openzwave.com/device-database/017f:0001:0200 + https://www.wink.com/products/wink-siren-and-chime/ + https://www.wink.com/help/products/ + images/wink/wnk-sir1p.png + + + 1. For proper inclusion, bring the Motion Detector within range of your Controller. + 2. Pull the tab on the side of the sensor to power on, or remove then re-install the batteries. + The LED indicator will flash five times indicating inclusion. + 1. Remove the sensor cover by twisting it counterclockwise and be sure it is powered on. + 2. Press the Connect Button on the bottom of the device next to the battery quickly 3 times in a row. + The LED Indicator will flash five times indicating exclusion/disconnection. + 1. Remove the sensor cover by twisting it counterclockwise and be sure it is powered on. + 2. Hold the Connect Button next to the battery for 10 seconds until the LED indicator blinks once, then release the button. + Only do this if the controller is disconnected or otherwise unreachable! + https://products.z-wavealliance.org/products/2484 + U.S. / Canada / Mexico + WNK-SIR1P + + Initial information based on Z-Wave alliance database information + + + + + + + Primary Notification Volume Level + + + + + + + Primary Notification Length + + + + + + + + -128 to -2 Chime Duration (in Minutes; -128=128 min, -2=254 min) + -1 Chime Will Not Play + 0 Does Not Stop + 1 to 127 Chime Duration (in Minutes) + + + + + Secondary Notification Volume Level + + + + + + + 1 to 10 Tone Index Number + + + + 1 to 10 Tone Index Number + + + + Short Help Description + + + + + + + + false + + + + + + + + + + + \ No newline at end of file diff --git a/openzwave/zipato/MiniKeypad.xml b/openzwave/zipato/MiniKeypad.xml new file mode 100644 index 00000000..b0300782 --- /dev/null +++ b/openzwave/zipato/MiniKeypad.xml @@ -0,0 +1,36 @@ + + + + + Set all configuration values to default values (factory settings). + + + To configure the time the beep is automatically turned off in seconds. + + + + + To configure the timeout to wait for a WAKEUP_NO_MORE_INFORMATION before the error beep is automatically sound. The error beeps are fixed 8 beeps shortly after each other. + + + To configure the number of beeps per second. Every beep is fixed about 10ms. + + + To configure the operating mode. If any mode other then 3, that value will be reported after a get but will be handled in SW as mode 1. + + + + + + + + false + + + + + + + + + diff --git a/openzwave/zipato/RGBBulb.xml b/openzwave/zipato/RGBBulb.xml new file mode 100644 index 00000000..1a1aeda9 --- /dev/null +++ b/openzwave/zipato/RGBBulb.xml @@ -0,0 +1,56 @@ + + + http://www.openzwave.com/device-database/0131:0002:0002 + images/zipato/RGBBulb.png + https://products.z-wavealliance.org/products/2034/ + Place your Z-Wave primary controller into inclusion mode by following the controller manufacturer's instructions. + +Place the light bulb into inclusion mode by gently tapping the +light bulb. The light bulb will shine green to indicate a successful +activation of inclusion mode. + rgbwe27zw.us + CEPT (Europe) / U.S. / Canada / Mexico + A factory default reset is performed when the bulb is excluded +from a Z-Wave network. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + Zipato RGBW BULB has 5 color channels available for you to adjust: +RED, GREEN, BLUE, WARM WHITE and COLD WHITE. Zipato RGBW +BULB can be used to add color to your home or just to lighten it up in +any white color tone you desire. + Place your Z-Wave primary controller into exclusion mode by following the controller manufacturer's instructions. + +Place the light bulb into exclusion mode by gently tapping the +light bulb. The light bulb will shine green to indicate a successful +activation of exclusion mode. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2034/rgbwe27zw - Zipato RGBW Bulb User Manual v1.1.pdf + Zipato RGBW light bulb + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1132/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2034/xml + + + + + + + Color Temperature + + + + + Shock sensor : 0=Maximum sensitivity ; 32=minimum sensitivity + + + + + + + + + + + + + + diff --git a/openzwave/zipato/RGBBulb2.xml b/openzwave/zipato/RGBBulb2.xml new file mode 100644 index 00000000..a6b491b7 --- /dev/null +++ b/openzwave/zipato/RGBBulb2.xml @@ -0,0 +1,24 @@ + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/zipato/ne-nas-ab02z.xml b/openzwave/zipato/ne-nas-ab02z.xml new file mode 100644 index 00000000..e94b3d9b --- /dev/null +++ b/openzwave/zipato/ne-nas-ab02z.xml @@ -0,0 +1,84 @@ + + + Indoor Siren + The indoor siren is an intelligent device that can be controlled remotely by the Z-wave network. The indoor siren is battery powered, small and easily installed. When the siren is triggered, an LED light will flash, and there will be an alarm sound at the same time. The sound level is at least 115 dB. + http://www.openzwave.com/device-database/0131:1083:0004 + https://www.zipato.com/product/indoor-siren + images/zipato/ne-nas-ab01z.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3046/ne-nas-ab02z.eu%20-%20Zipato%20INDOOR%20SIREN-waveEU_UserManual_v1.3.pdf + Quickly triple click the code button, LED light will flash red for 5 times. + Quickly triple click the code button, LED light will flash red for 5 times. + Make sure the sensor is connected to power source, Press the code button for 10 seconds, LED will flash blue for 3 seconds + https://products.z-wavealliance.org/products/3046 + CEPT (Europe) + ne-nas-ab02z.eu + + Information obtained from manual, z-wavealliance, re-brand documentation (https://products.z-wavealliance.org/products/3069), and trial & error + + + + + + + + This parameter defines the default sound index, volume and the duration time for siren on + + + + + + This parameter defines the output volume when siren plays alarm. + + + + + + + This parameter defines the alarm sound index so siren can play different sound when an alarm occurs. + + + + This Parameter defines the alarm duration time when siren receives an alarm sensor notification report or an alarm command from controller. + + + + + + + + + This parameter defines the default led enable status when siren is on for alarm + + + + + + This parameter defines the output volume when siren plays doorbell music + + + + + + + This parameter defines the doorbell music index so siren can play different music when an alarm occurs. + + + + This parameter defines the doorbell music duration time when siren receives a door/window sensor notification report or an alarm command (BASIC_SET=0x02) from a controller + + + + This parameter defines the default led enable status when siren is on for doorbell + + + + + + + + + + + + + diff --git a/openzwave/zipato/pan04.xml b/openzwave/zipato/pan04.xml new file mode 100644 index 00000000..9141ecba --- /dev/null +++ b/openzwave/zipato/pan04.xml @@ -0,0 +1,111 @@ + + + http://www.openzwave.com/device-database/0131:0012:0001 + images/zipato/pan04.png + https://products.z-wavealliance.org/products/2421/ + This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Micromodule Switch Double is a transceiver which is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled network. Mini size design allow the module to be easily hidden into the wall box which is good for the house decoration. There are many kinds of application for using the module to switch AC power ON and OFF, one of which is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kinds of light like incandescent, fluorescent and LED light. This Micromodule is able to detect Instant power wattage and overload wattage (current 7.5A) of connected light or appliances. When detecting overload state, the switch will be disabled and its ON/OFF button will be locked during which LED will flash repeatedly. Unplugging and reconnecting the Module will reset its overload condition to normal status. + Use this procedure only in the event that the network primary controller is lost or otherwise inoperable. +Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode. +Within 1 second, press On/Off button again for 5 seconds until LED is off. +IDs are excluded. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2421/ph-pan04 - Zipato MM Switch Double User Manual 165x295mm v1.5.pdf + ph-pan04.eu + Micro Module Switch Double w.meter + Have Z-Wave Controller entered inclusion mode by following the instructions provided by the controller manufacturer. +Pressing INCLUDE_BUTTON threetimes within 2 seconds will enter inclusion mode. + Have Z-Wave Controller entered exclusion mode by following the instructions provided by the controller manufacturer. +Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode. +Node ID has been excluded. + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2421/xml + + + + + true + + + + + + + If the setting is configured for 1hour (set value =720), Micromodule will report its instant power consumption every 1 hour to the node of correspond Group. + The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). + + + + If the setting is configured for 1hour (set value =6), Micromodule will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. + The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). + + + If Micromodule is not using Multi_Channel command class to access the relay of Switch, you may configure the select value to react the Basic Command Class, Binary Switch Command Class or Meter Command Class V3. + + + + + + Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode. + 1) Edge : This mode is suitable for the bi stable wall switch that has indicator point on the Micromodule, and the same position correspond to same state of relay1 and relay2. if the Switchs relay changes the state because of receiving Z-Wave RF command, it may need two switchings (switch on to off or switch off to on) to let relay back to the corresponding state. + 2) Pulse : this mode is suitable for the toggle type wall switch to swap the state of Relay1 or Relay2. + 3) Edge-Toggle : This mode is suitable for the normal bi-stable switch, every state change of the wall switch will also swap the state of Relay1 or Relay2. + + + + + + This is a warning when the wattage of load over the preset threshold value, If the setting value is 750, when the load wattage of Relay1 or Relay2 over this value, Micromodule will send Watt Meter Report command to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750. + + + This is a warning when the KWh of load exceeds preset threshold value, If the setting value is 1000, when the Accumulated Power Consumption of Relay1 or Relay2 exceeds this value, Micromodule will send KWh Meter Report command to the node of corresponding Group, the Range of the setting value is from 10 to 1000, and the default value is 750. + + + Whenever the AC power return from lost, Micromodule will restore the switch state which could be + + + + + + + Whenever Micromodule switches to on, the auto off timer begin to count down. + After the timer decrease to zero, it will switch off automatically. + However if Auto off timer is set as 0, the auto off function will be disabled. + The default setting is 0. + + + + + Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of commands. + + + + + + + + + Multi-Channel Command is a good way to control relay1 and relay2 of Switch individually. + The endpoint3 of Micromodule is related to both relay1 and relay2. + In some condition it becomes redundant in Multi-Channel Command Class. + When the Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. + The default value is 1. + Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic. + + + + + + + + + + + + + + + + diff --git a/openzwave/zipato/vszd2102.xml b/openzwave/zipato/vszd2102.xml new file mode 100644 index 00000000..b19594cf --- /dev/null +++ b/openzwave/zipato/vszd2102.xml @@ -0,0 +1,43 @@ + + + http://www.openzwave.com/device-database/0131:0106:2001 + images/zipato/vszd2102.png + https://products.z-wavealliance.org/products/1864/ + The ZD2102-5 is forced awake by opening the rear cover, the red LED will stay on and the 2102-5 will stay awake for 10 seconds. The ZD2102-5 will send “Wake Up Notification”. If ZD2102-5 receives a “Wake Up No More Information” command then the red LED will go off and it will go to sleep. +Auto Wake Up: The wakeup interval is user settable from 10 minutes to 1 week using COMMAND_CLASS_WAKE_UP, Interval increment is 3 minutes. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1864/vs-zd2102 - Zipato Door+Window Sensor User Manual v1.5.pdf + The ZD2102-5 Door and Window sensor is used in any Z-Wave network to detect the opening or closing of a door or window. Special Design can fit most of door/window frame. The primary sensing element is a magnetic reed switch, the ZD2102-5 is supplied with the sensor, sensor mounting bracket and the trigger magnet. An additional set of sensor inputs are provided through a 2 position screw terminal and can be used to expand the sensor capability to multiple inputs. The ZD2102-5 is powered by a single CR123A Lithium Battery (supplied with unit, battery life is more than 5 years) and is intended for indoor use only. The ZD2102-5 features tamper proof switch, low battery warning and can be firmware updated over the air. + For “Inclusion” (adding to) a network: Put the Z-Wave™ network controller into “inclusion” mode following its instructions. To add the ZD2102-5 to your controller press the program switch of ZD2102-5 to send the Node Information Frame (NIF). After sending NIF, the network controller will send the auto inclusion request; otherwise, ZD2102-5 will go to sleep after 15 seconds. + Door Sensor + For “Exclusion” (removing from) a network: Put the Z-Wave™ network controller into “exclusion” mode, following its instructions. To delete the ZD2102-5 from your controller press the program switch of ZD2102-5 for at least 1 second to be excluded. Note: All user and network settings will be cleared and the device reset to factory setting defaults when the device is excluded. + ZD2102US-5 + Factory Default Reset: Trigger the rear cover switch to send the Alarm Report and trigger the reed switch (close & open) 5 times in 10 seconds, ZD2102-5 will send the “Device Reset Locally Notification” command and reset to the factory default condition. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.) + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1864/xml + + + + + + + + true + + + + + + false + + + + + + + + + diff --git a/openzwave/zipato/zp3102.xml b/openzwave/zipato/zp3102.xml new file mode 100644 index 00000000..e21e7370 --- /dev/null +++ b/openzwave/zipato/zp3102.xml @@ -0,0 +1,76 @@ + + + http://www.openzwave.com/device-database/0131:0205:2002 + images/zipato/zp3102.png + https://products.z-wavealliance.org/products/1978/ + It will be triggered after opening the front cover. +Red LED will last 10 seconds and Multisensor Duo will send “Wake +Up Notification” after 10 seconds. + Put your Z-Wave +Controller into “inclusion” mode, and follow the instructions to add +Multisensor Duo to your controller. To get in the “inclusion” mode, +the distance between sensor and controller should be up to 1 meter. +Press the program switch of Multisensor Duo once. The LED on the +sensor should stop flashing, if not, please try again. + U.S. / Canada / Mexico / CEPT (Europe) + Zipato Multisensor Duo + Remove cover to trigged tamper +switch, LED ON & send out Alarm Report. Press Program Switch +10 times within 10 seconds. Multisensor Duo will send the “Device +Reset Locally Notification” command and reset to the factory +default settings. + +(Remark: This is to be done only in case of primary +controller being inoperable or otherwise unavailable.) + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1978/manual.pdf + Put your +Z-Wave Controller into “exclusion” mode, and follow the instructions +to remove the Multisensor Duo from you controller network. Press +the program switch of Multisensor Duo once to be excluded. The +LED on the Multisensor Duo should start to flash. + Motion and temperature sensor in one device. Zipato +Multisensor Duo offers elaborate security and ambient sensing +options. Multi-functional nature of this product allows you to detect +motion, and measure room temperature. When used with Zipato +home automation controllers it can be part of any automation +scenario created using Zipato Rule Creator. Accordingly it can be +used to automatically trigger other devices when activated. + vs-zp3102+.eu + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1969/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1978/xml + + + + + + Time until an associated device will turn off if no new movement is detected + + + Report temperature in Celcius or Fahrenheit + + + + + Sensitivity 1-7 (1 = most sensitive, 7 = most insensitive. 4 is default) + + + -10 to -1, 0 to 10 (Signed decimal: 246 to 255, 0 to 10) + + + + + + true + + + + + + + + + diff --git a/openzwave/zooz/zen06.xml b/openzwave/zooz/zen06.xml new file mode 100644 index 00000000..d8ab4d8d --- /dev/null +++ b/openzwave/zooz/zen06.xml @@ -0,0 +1,116 @@ + + + http://www.openzwave.com/device-database/027A:000A:0101 + images/zooz/zen06.png + https://products.z-wavealliance.org/products/1901/ + Product features: +- Manual and remote on / off control +- Energy monitoring +- Scene inclusion for custom automation scenarios when included to a Z-Wave gateway controller +- LED indicator displaying Z-Wave signal strength and power usage +- Security enabled Z-Wave device with AES signal encryption (requires a security enabled gateway controller for full functionality) +- Z-Wave Plus with improved 500 chip for faster and safer wireless communication +- Built-in range extender for a stronger, more reliable network +- 2 USB charging ports for your smart phone or tablet (no Z-Wave functionality) +- Built-in overload protection in Z-Wave outlet and USB ports + +Product Specifications: +Model Number: ZEN06 +Z-Wave Signal Frequency: 908.42 MHz +Power: 110V, 60Hz +Maximum Load: 15A, 1800W +USB Charging Port Power: 1A and 2.4A +Operating Temperature: 14 – 104 F +Range: Up to 130 feet line of sight +Installation and Use: Indoor only +Dimensions: 4” x 2.5” x 1.2” +Weight: 7oz + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1901/Zooz-Z-Wave-Smart-Plug-ZEN06 Manual.pdf + U.S. / Canada / Mexico + Zooz Z-Wave Smart Plug + Auto Z-Wave Inclusion +1. Put your Z-Wave controller in inclusion mode +2. Plug the smart plug into a grounded receptacle located within 3 feet from your Z-Wave gateway controller +3. LED indicator will flash blue +4. A new on / off device should be recognized by your Z-Wave controller + +Manual Z-Wave Inclusion +1. Plug the smart plug into a grounded receptacle located within 3 feet from your Z-Wave gateway controller +2. Put your Z-Wave controller in inclusion mode +3. Press and release the Z-Wave button 3 TIMES QUICKLY +4. LED indicator will flash blue +5. A new on / off device should be recognized by your Z-Wave controller + +Secure Z-Wave Inclusion +1. Plug the smart plug into a grounded receptacle located within 3 feet from your Z-Wave gateway controller +2. Put your Z-Wave controller in secure inclusion mode +3. Press and HOLD the Z-Wave button for at least 3 seconds +4. LED indicator will flash green +5. LED indicator will turn solid green once the inclusion is completed. Please allow 5 minutes for configuration. DO NOT press any buttons or move the device during that time +6. A new secure on / off device should be recognized by your Z-Wave controller + + ZEN06 + When your network’s primary controller is missing or otherwise inoperable, you may need to reset the device to factory settings manually. In order to complete the process, plug the smart plug into a grounded receptacle, then PRESS AND HOLD the Z-Wave button for AT LEAST 20 SECONDS. The LED indicator will stay solid yellow for 2 seconds to indicate successful reset. The plug will then automatically turn off. +NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. You may only reset your smart plug once it has been included to a Z-Wave network. + 1. Plug the smart plug into a grounded receptacle located within 3 feet from your Z-Wave gateway controller +2. Put your Z-Wave controller in exclusion mode +3. Press and release the Z-Wave button 3 TIMES QUICKLY +4. LED indicator will flash orange +5. The smart plug should disappear from your controller's device list and LED indicator will remain solid orange for a few seconds to indicate exclusion + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1901/xml + + + + + + + + turns relay off once voltage exceeds 16.5A for over 5 secs if enabled + + + + + Recovery state for power failure + + + + + + Send notifications to associated devices + + + + + + LED Indicator Control + + + + + Minimum change in watts to report + + + Minimum percentage change to report + + + How often to report power consumption (W) in secs + + + How often to report energy usage (KWH) in secs + + + How often to report voltage (V) in secs + + + How often to report electrical current (A) in secs + + + + + + + + + diff --git a/openzwave/zooz/zen07.xml b/openzwave/zooz/zen07.xml new file mode 100644 index 00000000..618e790a --- /dev/null +++ b/openzwave/zooz/zen07.xml @@ -0,0 +1,66 @@ + + + + + + + + Choose if you want the Mini Plug to send metering reports to the controller. + + + + + Choose how often you want the Mini Plug to send metering reports to the controller, in seconds. + + + Percentage change of electricity, voltage, power consumption, or energy before report is sent. + Defaults to 5%. + + + Use this parameter to adjust the max amount of electricity you want your Mini Plug to handle, by Amperes. + Defaults to 13A. + + + Use this parameter to adjust the LED Notification for Heavy Load by setting a threshold of Amperes. + Must be lower than Parameter #3. + Defaults to 12A + + + Use this parameter to turn LED notifications on or off. + + + + + Choose the recovery state for the Mini Plug if power outage occurs. Off sets the state to "OFF" once power is restored. + Resume sets the state to the previous state prior to the outage. + Defaults to Resume. + + + + + Use this parameter to enable or disable the auto turn-off timer function. + If enabled, the Mini Plug will automatically turn off after a fixed period of time, set in Parameter #9. + Defaults to Disabled. + + + + + Use this parameter to set the time, in minutes, after which the Mini Plug should turn off if Auto Turn-Off Timer is Enabled (Parameter #8). + Defaults to 150 minutes. + + + Choose if you want the Z-Wave button to turn the Mini Plug on or off manually, or if you want to disable this function. Defaults to Enabled. + + + + + + + + + + + + + + diff --git a/openzwave/zooz/zen15.xml b/openzwave/zooz/zen15.xml new file mode 100644 index 00000000..25a0d15a --- /dev/null +++ b/openzwave/zooz/zen15.xml @@ -0,0 +1,123 @@ + + + http://www.openzwave.com/device-database/027A:000D:0101 + images/zooz/zen15.png + https://products.z-wavealliance.org/products/2517/ + 1. Plug the Power Switch into a grounded receptacle located within direct range of your Z-Wave gateway controller +2. Put your Z-Wave controller into exclusion mode +3. Press and release the Z-Wave button 3 TIMES QUICKLY +4. The LED indicator will start flashing orange, then turn blue (on) or pink (off) once excluded +5. The Power Switch will disappear from your controller's device list. The LED indicator will remain solid orange for a few seconds to indicate exclusion + +If the first attempt is unsuccessful, please repeat the process following all steps carefully. + Zooz Z-Wave Plus Power Switch + PRODUCT FEATURES: +Local and Z-Wave wireless control of your favorite home appliances like microwaves and refrigerators. + +Energy monitoring in live mode or over time (your Z-Wave gateway needs to support this feature). + +Scene inclusion for custom automation events when included to a Z-Wave gateway controller. + +On/Off status recovery after power failure. + +LED indicator to display Z-Wave signal strength and power usage for the connected device. + +Added security with AES signal encryption (requires a security enabled gateway controller for full functionality). + +Z-Wave Plus with improved 500 chip for faster and more reliable wireless communication. + +Built-in range extender. + +SPECIFICATIONS: +Model Number: ZEN15 +Z-Wave Signal Frequency: 908.42 MHz +Power: 120V, 60Hz +Maximum Load: 15A, 1800W, ½ HP +Operating Temperature: 14° – 104° F +Range: Up to 130 feet line of sight +Installation and Use: Indoor only +Dimensions: 20” (with cord) x 2.6” x 1.1” +Weight: 10oz + ZEN15 + U.S. / Canada / Mexico + When your network’s primary controller is missing or otherwise inoperable, you may need to reset the device to factory settings manually. In order to complete the process, plug the Power Switch into a grounded receptacle, then PRESS AND HOLD the Z-Wave button for AT LEAST 20 SECONDS. The LED indicator will flash orange and then stay solid orange for 2 seconds to indicate successful reset. The Power Switch will then turn off. + +NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. You may only reset your Power Switch once it has been included to a Z-Wave network. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2517/zooz-z-wave-plus-power-switch-zen15-user-manual.pdf + Please include the Power Switch to your network BEFORE connecting it to the appliance you wish to control. + +Auto Z-Wave Inclusion: +1. Put your Z-Wave controller into inclusion mode +2. Plug the Power Switch into a grounded receptacle located within direct range from your Z-Wave gateway controller +3. The LED indicator will start flashing blue, then turn blue (on) or pink (off) once included +4. A new on / off device will be recognized by your Z-Wave controller + +Manual Z-Wave Inclusion: +1. Plug the Power Switch into a grounded receptacle located within direct range from your Z-Wave gateway controller +2. Put your Z-Wave controller into inclusion mode +3. Press and release the Z-Wave button 3 TIMES QUICKLY +4. The LED indicator will start flashing blue, then turn blue (on) or pink (off) once included +5. A new on / off device will be recognized by your Z-Wave controller + +Secure Z-Wave Inclusion: +1. Plug the Power Switch into a grounded receptacle located within direct range from your Z-Wave gateway controller +2. Put your Z-Wave controller in secure inclusion mode +Press and HOLD the Z-Wave button for at least 3 seconds +3. The LED indicator will start flashing green, then turn blue (on) or pink (off) once included +4. A new secure on / off device will be recognized by your Z-Wave controller + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2517/xml + + + + + + + Overload protection. + + + + + Choose the recovery state for your Power Switch if power outage occurs. + + + + + + Send On/Off Status Change Notifications + + + + + + 0 - LED indicator will display power consumption whenever the device is plugged in. 1 - LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off + + + + + Number of Watts the appliance needs to go over for the change to be reported + + + Percentage in power usage change the appliance needs to go over for the event to be reported (Default 10) + + + Number of seconds + + + Number of seconds + + + Number of seconds + + + Number of seconds + + + + + + + + + diff --git a/openzwave/zooz/zen16.xml b/openzwave/zooz/zen16.xml new file mode 100644 index 00000000..847a48ca --- /dev/null +++ b/openzwave/zooz/zen16.xml @@ -0,0 +1,167 @@ + + + + Multirelay + PRODUCT FEATURES: +- Powerful dry contact relays to control loads up to 15 A and 20 A +- Perfect for outdoor lighting, pool pumps, garage door, or gas fireplace +- Control up to 3 connected loads independently or together +- Z-Wave or optional wall switch control (toggle or momentary type) +- Built-in timers for each relay to simplify automation +- Remembers and restores on/off status after power failure +- Powered by 12-24 V DC/AC or USB C port for easy set-up +- Wall mounting and minimal design for clean installation +- S2 security protocol and the latest 500 Z-Wave chip + +SPECIFICATIONS: +- Model Number: ZEN16 +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 12-24 V DC/AC or USB C +- Maximum Load: Relay 1: 15A (1/3 HP), Relay 2: 15A (1/3 HP),Relay 3: 20A (3/4 HP) + + http://www.openzwave.com/device-database/027a:a00a:a000 + http://www.getzooz.com/ + http://www.support.getzooz.com/home/ + images/zooz/zen16.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3788/zooz-s2-multirelay-zen16-ver1.0-manual-online.pdf + 1. Initiate inclusion (pairing) in the app (or web interface) of your hub. 2. Finalize inclusion at the device. Click the Z-Wave button 3 times quickly to add the MultiRelay to your network. The LED indicator will blink to signal communication and remain on for 2 seconds to confirm inclusion. + + 1. Bring your MultiRelay close to the Z-Wave gateay (hub) and power it. +2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com +3. Click the Z-Wave button 3 times quickly +4. Your hub will confirm exclusion and the device will disappear from your controller's device list + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, click the Z-Wave button 4 times quickly, the LED indicator will light up, then quickly click the Z-Wave button 4 times again. The LED indicator will flash 3 times to confirm successful reset and will then turn off. + + https://products.z-wavealliance.org/products/3788 + U.S. / Canada / Mexico + ZEN16 + + Initial Metadata Import + Updated for firmware version 1.02 + + + + + + + + + On Off Status After Power Failure. Default: all relays restore to previous state + + + + + + + + Switch Type for Relay 1 (Sw1). Choose the wall switch type you want to connect to the Sw1 terminal. Default: toggle switch (state changes whenever the switch is toggled) + + + + + + + Switch Type for Relay 2 (Sw2). Choose the wall switch type you want to connect to the Sw2 terminal. Default: toggle switch (state changes whenever the switch is toggled) + + + + + + + Switch Type for Relay 3 (Sw3). Choose the wall switch type you want to connect to the Sw3 terminal. Default: toggle switch (state changes whenever the switch is toggled) + + + + + + + LED Indicator Control. Choose if you want the LED indicator to turn on when any of the relays are on or if all of them are off, or if you want it to remain on or off at all times. Default: On when all relays are off + + + + + + + Auto Turn-Off Timer for Relay 1. Sets the time (in minutes) after which you want relay 1 to automatically turn off once it has been turned on. Range: 1-65535. Default: 0 (disabled) + + + Auto Turn-On Timer for Relay 1. Sets the time (in minutes) after which you want relay 1 to automatically turn on once it has been turned off. Range: 1-65535. Default: 0 (disabled) + + + Auto Turn-Off Timer for Relay 2. Sets the time (in minutes) after which you want relay 2 to automatically turn off once it has been turned on. Range: 1-65535. Default: 0 (disabled) + + + Auto Turn-On Timer for Relay 2. Sets the time (in minutes) after which you want relay 2 to automatically turn on once it has been turned off. Range: 1-65535. Default: 0 (disabled) + + + Auto Turn-Off Timer for Relay 3. Sets the time (in minutes) after which you want relay 3 to automatically turn off once it has been turned on. Range: 1-65535. Default: 0 (disabled) + + + Auto Turn-On Timer for Relay 3. Sets the time (in minutes) after which you want relay 3 to automatically turn on once it has been turned off. Range: 1-65535. Default: 0 (disabled) + + + Enable/Disable Manual Control for SW1. Default: enabled + + + + + + Enable/Disable Manual Control for SW2. Default: enabled + + + + + + Enable/Disable Manual Control for SW3. Default: enabled + + + + + + Choose between second, minutes, and hours as the unit for Auto Turn-Off time for Relay 1. Default: minutes + + + + + + Choose between second, minutes, and hours as the unit for Auto Turn-On time for Relay 1. Default: minutes + + + + + + Choose between second, minutes, and hours as the unit for Auto Turn-Off time for Relay 2. Default: minutes + + + + + + Choose between second, minutes, and hours as the unit for Auto Turn-On time for Relay 2. Default: minutes + + + + + + Choose between second, minutes, and hours as the unit for Auto Turn-Off time for Relay 3. Default: minutes + + + + + + Choose between second, minutes, and hours as the unit for Auto Turn-On time for Relay 3. Default: minutes + + + + + + + + + + + + + + + + diff --git a/openzwave/zooz/zen20.xml b/openzwave/zooz/zen20.xml new file mode 100644 index 00000000..acd98701 --- /dev/null +++ b/openzwave/zooz/zen20.xml @@ -0,0 +1,44 @@ + + + http://www.openzwave.com/device-database/015D:F51C:0651 + images/zooz/zen20.png + https://products.z-wavealliance.org/products/1646/ + U.S. / Canada / Mexico + 1. Follow the instructions for your Z-Wave certified controller to include a device to + the Z-Wave network. +2. Once the controller is ready to include your device, press up and release the toggle + to include it in the network. +3. Once your controller has confirmed that the device has been included, refresh the + Z-Wave network to optimize performance. +4. The device is associated in the same group when it included in setting process. + Now you can control your Z-Wave device according to groups, scenes, schedules and automation programmed. + + The 5 outlets power strip provides five Z-Wave outlets for remote controlled by controller through Z-Wave gateway for internet of thing service and can be configured in Z-Wave sensor network, if Z-Wave certified controller features remote access, you can now control five outlets from your mobile phone each one. Five outlets can +manual On/Off the same time by push button. The two USB ports provide 5V/2.1A charging power for MP3/ mobile phone.etc.. + + 1. Follow the instructions for your Z-Wave certified controller to exclude a device + from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press up and release the toggle + to exclude it from the network. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1646/ZW1505-Manual0130.pdf + 1. Press and hold the top button for at least 3 seconds while you plug the smart + switch into a receptacle. +2. Use this procedure only in the event that the network primary controller is missing + or otherwise inoperable. + + 5 Outlet Power Strip with USB charger + ZW 1505 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1646/xml + + + + + + + + + + + diff --git a/openzwave/zooz/zen20v2.xml b/openzwave/zooz/zen20v2.xml new file mode 100644 index 00000000..d8e5c066 --- /dev/null +++ b/openzwave/zooz/zen20v2.xml @@ -0,0 +1,205 @@ + + + http://www.openzwave.com/device-database/027A:A004:A000 + images/zooz/zen20v2.png + https://products.z-wavealliance.org/products/3158/ + FEATURES: + +- Z-Wave on/off control of up to 5 electrical devices +- On/off (charging/charged) reports from USB ports to the hub (no Z-Wave control) - turn off the charging device for best results +- Energy monitoring for each of the 5 outlets +- Built-in overload protection and ETL certification +- Z-Wave Plus signal repeater to extend network range +- S2 security protocol and the latest 500 Z-Wave chip for faster and safer wireless communication + +SPECS: +- Model Number: ZEN20 VER. 2.0 +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 120 VAC +- Maximum Load: 15 A total (between 5 outlets) +- Maximum Load for USB ports: 2.1 A total (between 2 ports) +- Cord Length: 2 feet +- Range: Up to 100 feet line of sight +- Installation and Use: Indoor only + 5-Outlet Power Strip + ZEN20 VER. 2.0 + 1. Bring the strip within direct range of your Z-Wave gateway (hub). +2. Put the Z-Wave hub into exclusion mode. +3. Press and release the CH1 button 3 times quickly. +4. Your hub will confirm exclusion and all of the channels (child outlets) and the main device will disappear from your controller's device list. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3158/zooz-s2-z-wave-plus-power-strip-zen20-ver2-online-manual.pdf + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, click-click-click’n’hold CH1 button for at least 10 seconds. All LED indicators will flash to confirm successful reset. +NOTE: All previously recorded activity and custom settings EXCEPT for the kWh record will be erased from the device’s memory. + U.S. / Canada / Mexico + 1. Plug the Power Strip into a grounded receptacle you’re planning to use it at (it doesn’t need to be close to the hub) +2. Initiate inclusion (pairing) in the app (or web interface). +3. CLICK CH1 BUTTON 3 TIMES QUICKLY. All LED indicators will start flashing +4. You will see 7 or 8 new on/off devices in your app: 5 channels or on/off control, 2 channels for on/off monitoring (USB ports reporting charging/ charged status, no control), and possibly one master node to access and adjust advanced settings in. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3158/xml + Update parameters for firmware 2.0.3 + + + + + + + + + Status after Power Failure + + + + + + 0 = power meter disabled; 1-65535 = value in watts for report threshold + + + 0 = disabled; 30-2678400 = time in seconds to send power wattage report + + + 0 = disabled; 30-2678400 = time in seconds to send energy report + + + 0 = disabled; 1-1800 = value in watts for overload protection + + + Enable or Disable auto turn-off timer for CH1 + + + + + Value in minutes for auto-off timer for CH1, if enabled + + + Enable or Disable auto turn-off timer for CH1 + + + + + Value in minutes for auto-on timer for CH1, if enabled + + + Enable or Disable auto turn-off timer for CH2 + + + + + Value in minutes for auto-off timer for CH2, if enabled + + + Enable or Disable auto turn-off timer for CH2 + + + + + Value in minutes for auto-on timer for CH2, if enabled + + + Enable or Disable auto turn-off timer for CH3 + + + + + Value in minutes for auto-off timer for CH3, if enabled + + + Enable or Disable auto turn-off timer for CH3 + + + + + Value in minutes for auto-on timer for CH3, if enabled + + + Enable or Disable auto turn-off timer for CH4 + + + + + Value in minutes for auto-off timer for CH4, if enabled + + + Enable or Disable auto turn-off timer for CH4 + + + + + Value in minutes for auto-on timer for CH4, if enabled + + + Enable or Disable auto turn-off timer for CH5 + + + + + Value in minutes for auto-off timer for CH5, if enabled + + + Enable or Disable auto turn-off timer for CH5 + + + + + Value in minutes for auto-on timer for CH5, if enabled + + + Enable or Disable Manual Controll for out Outlets + + + + + Normal = LED indicator is on when power is on, off when power is off. Inverse = LED indicator is off when power is on, and on when power is off. Always Off = LED indicator is always off, regardless of power status. + + + + + + Disable or enable energy monitoring for the entire devie. None of the outlets will send any power or energy related reports back to the hub if energy monitoring is disabled. Use this optoin to minimize the amount or reports you want to receive from the Power Strip. (Firmware > 2.0.3) + + + + + Disable or enabled energy monitoring for CH1. (Firmware > 2.03) + + + + + Disable or enabled energy monitoring for CH2. (Firmware > 2.03) + + + + + Disable or enabled energy monitoring for CH3. (Firmware > 2.03) + + + + + Disable or enabled energy monitoring for CH4. (Firmware > 2.03) + + + + + Disable or enabled energy monitoring for CH5. (Firmware > 2.03) + + + + + Disable or enable on/off reports send from the USB ports when a connected device is charging (drawing power) or not charging (not drawing power). (Firmware > 2.03) + + + + + 0 = disabled; 30-2678400 = time in seconds to send current (A) report (Firmware > 2.03) + + + 0 = disabled; 30-2678400 = time in seconds to send voltage (v) report (Firmware > 2.03) + + + + + + + + + diff --git a/openzwave/zooz/zen21.xml b/openzwave/zooz/zen21.xml new file mode 100644 index 00000000..a8e0335e --- /dev/null +++ b/openzwave/zooz/zen21.xml @@ -0,0 +1,56 @@ + + + http://www.openzwave.com/device-database/015D:231C:0111 + images/zooz/zen21.png + https://products.z-wavealliance.org/products/1945/ + 1. Press and hold the top button for at least 3 seconds while you apply AC power to this device. +2. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. + + 1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. +2. Once the controller is ready to Exclude your device, press up and release the front button to exclude it from the network. + + In-wall Smart Switch + U.S. / Canada / Mexico + 1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network. +2. Once the controller is ready to include your device, press up and release the toggle to include it in the network. +3. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. +4. The device is associated in the same group when it included in setting process. +Now you can control your Z-Wave device according to groups, scenes, schedules and automation programmed. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2348/ZW30manual170412.pdf + ZEN21 + It is an In-wall type device controlled by Z-Wave controller and can be configured in Z-Wave sensor network, if Z-Wave certified controller features remote access, you can control lights at home from your mobile phone separately, and manual On/Off light by push button . + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1945/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2348/xml + + https://products.z-wavealliance.org/products/2348/ + U.S. / Canada / Mexico + ZW30 + + + + + + Controls the on/off orientation of the rocker switch + + + + + Choose if you want the LED indicator to turn on when switch is on or off + + + + + Enable or disable LED indicator so it stays off at all times + + + + + + + + + + + diff --git a/openzwave/zooz/zen21v3.xml b/openzwave/zooz/zen21v3.xml new file mode 100644 index 00000000..ca3c9cd9 --- /dev/null +++ b/openzwave/zooz/zen21v3.xml @@ -0,0 +1,157 @@ + + + + http://www.openzwave.com/device-database/027a:1e1c:b111 + images/zooz/zen21v3.png + https://products.z-wavealliance.org/products/3667?selectedFrequencyId=2 + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, tap-tap-tap’n’hold the upper paddle for at least 10 seconds. The LED indicator will flash to confirm successful reset. +NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. + 1. Bring your Z-Wave gateway (hub) close to the switch if possible +2. Put the Z-Wave hub into exclusion mode (not sure how to do that? +ask@getzooz.com) +3. Tap the lower paddle on the switch 3 times quickly + 1. Initiate inclusion (pairing) in the app (or web interface) of your hub. +2. Tap the upper paddle on the switch 3 times quickly. + U.S. / Canada / Mexico + ZEN21 + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3667/zooz-z-wave-plus-on-off-switch-zen21-ver3.1-manual.pdf + Z-WAVE PLUS ON / OFF LIGHT SWITCH + FEATURES: +- Manual and remote on/off control for lights and small appliances +- Unique Direct 3-Way Solution: no add-on switch needed, extra savings! (Neutral wire required, use in 4-Way only if direct connection to load and line are in the same box) +- Scene control on selected hubs +- Reports on/off status to your controller instantly +- NEW VERSION: more advanced settings (timer, turn switch on/off with any paddle, choose state after power failure), improved manual and packaging +- White (no other color available) +- Restores on/off status after power failure +- Can be associated with other Z-Wave devices by scheduling scenes and customizing events +- Compatible with LED, CFL, and incandescent bulbs +- Screw terminal installation - requires Line (Hot), Load, Neutral, and Ground wires +- New and improved Z-Wave Plus 500 series chip for faster, stronger wireless connectivity +- Built-in repeater that strengthens your Z-Wave network +- Blue LED indicator to easily locate the switch in the dark and signal Z-Wave communication +- Use a standard-size wall plate for single gang installations (wall plate not included) +- UL-listed and Z-Wave Plus certified + +SPECIFICATIONS: +- Model Number: ZEN21 + +- Z-Wave Frequency: 908.42 MHz (US) +- Power: 120 VAC, 60 Hz +- Maximum Loads: 960W Incandescent, 150W LED and CFL bulbs, 1800W (15A) Resistive +- Z-Wave Range: Up to 100 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module +- Operating Temperature: 32-104° F (0-40° C) +- Installation: Indoor use only + +https://www.support.getzooz.com/kb/article/316-zooz-on-off-switch-zen21-ver-3-04-advanced-settings/ +MANUAL CONTROL +Upper Paddle: +1 x tap: load on; Scene 1, attribute 00 (button 1) +2 x tap: Scene 1, attribute 03 (button 3) +3 x tap: enter inclusion (pairing) mode; Scene 1, attribute 04 (button 5) +4 x tap: Scene 1, attribute 05 (button 7) +6 x tap: change LED indicator mode (see parameter 2) +10 x tap: change physical / Z-Wave control mode (see parameter 11) +tap-tap-tap-and-hold: factory reset + +Lower Paddle: +1 x tap: load off; Scene 2, attribute 00 (button 2) +2 x tap: Scene 2, attribute 03 (button 4) +3 x tap: enter exclusion (unpairing) mode; Scene 2, attribute 04 (button 6) +4 x tap: Scene 2, attribute 05 (button 8) +tap-tap-tap-and-hold: factory reset + + + Updated for firmware version 3.04 + Rename XML for correct hardware version + Update parameter 12 description + + + + + + Normal mode: Upper paddle turns the light on, lower paddle turns the light off. Reverse mode: Upper paddle turns the light off, lower paddle turns the light on. Toggle mode: Either paddle toggles the light. + + + + + + LED Indication light function. Normal has the LED Indication on when the switch is off, off when the switch is on. + + + + + + + + + + + + Time, in minutes, for auto-off timer delay. + + + + + + + + Set the time (in minutes) after which you want the switch to automatically turn on once it has been turned off. + + + Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to associated devices. + + + + + + + + + + + + + + + + + + + Status after power failure. Off: always turn light off. On: always turn light on. Restore: remember the latest state and restore that state. + + + + + + Enable or Disable scene control functionality for quick double tap triggers (Available for select hubs only). + + + + + Enable or disable local on/off control. If enabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through paddles. + + + + + + Choose the type of 3-way switch you want to use with this switch in a 3-way set-up. + + + + + Set reporting behavior for disabled physical control. + + + + + + + + + + + + + + diff --git a/openzwave/zooz/zen22.xml b/openzwave/zooz/zen22.xml new file mode 100644 index 00000000..1e1ee209 --- /dev/null +++ b/openzwave/zooz/zen22.xml @@ -0,0 +1,54 @@ + + + http://www.openzwave.com/device-database/015D:241C:0112 + images/zooz/zen22.png + https://products.z-wavealliance.org/products/1946/ + The switch will be reset to factory defaults only by exclusion using a Z-Wave controller. You may use any certified Z-Wave controller to exclude and reset the switch. This device may not be reset manually when the network’s primary controller is missing or otherwise inoperable. NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. + PRODUCT FEATURES: +- Manual or remote on/off control and dimming from your mobile device or computer (when included to a Z-Wave gateway controller) +- Z-Wave Plus with improved 500 chip for faster and safer wireless communication +- Works with most high-quality DIMMABLE LED, CFL, and incandescent bulbs +- Based on universal command classes - supported by most Z-Wave controllers +- May be associated and grouped with other Z-Wave devices for advanced home automation +- LED indicator to help locate the switch in dark space +- Simple elegant design with screwless snap-on wall plate included +- Built-in Z-Wave signal repeater for a stronger and more reliable network + +SPECIFICATIONS: +Model Number: ZEN22 +Z-Wave Signal Frequency: 908.42 MHz +Power: 120 VAC, 60 Hz +Maximum Loads: 500W Single-gang, 400W Double-gang, 300W Triple-gang Incandescent, 150W CFL or LED +Range: Up to 100 feet line of sight +Operating Temperature: 32-104° F (0-40° C) +Installation and Use: Indoor only + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1946/zooz-z-wave-plus-dimmer-switch-zen22-manual.pdf + U.S. / Canada / Mexico + 1. Bring your Z-Wave gateway hub or controller as close to the switch as possible +2. Put your Z-Wave controller in exclusion mode +3. Tap the switch on and off quickly 3 times to complete the exclusion process +4. The device should disappear from your controller's device list + ZEN22 + Zooz Z-Wave Dimmer Light Switch + 1. Bring your Z-Wave gateway hub or controller as close to the switch as possible +2. Put your Z-Wave controller in inclusion mode +3. Tap the switch on and off quickly 3 times to finalize the inclusion process +4. A new dimming device should appear on your controller's device list + +Troubleshooting Tips: +If you are unable to include the Z-Wave dimmer to your controller, please try one of the following: +- Bring the controller closer to your Z-Wave switch or use a hand-held secondary controller for inclusion +- Tap your Z-Wave switch quicker 4 or 5 times once you put the controller in the inclusion mode to ensure the command has gone through +- Put your controller in the EXCLUSION mode and tap the switch quickly 3 times, then try adding it to your network again + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1946/xml + + + + + + + + + + diff --git a/openzwave/zooz/zen22v2.xml b/openzwave/zooz/zen22v2.xml new file mode 100644 index 00000000..6b88e43a --- /dev/null +++ b/openzwave/zooz/zen22v2.xml @@ -0,0 +1,195 @@ + + + + http://www.openzwave.com/device-database/027a:1f1c:b112 + images/zooz/zen22.png + https://products.z-wavealliance.org/products/1946?selectedFrequencyId=2 + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, tap-tap-tap’n’hold the upper paddle for at least 10 seconds. The LED indicator will flash to confirm successful reset. +NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. + 1. Bring your Z-Wave gateway (hub) close to the switch if possible +2. Put the Z-Wave hub into exclusion mode (not sure how to do that? +ask@getzooz.com) +3. Tap the lower paddle on the switch 3 times quickly + 1. Initiate inclusion (pairing) in the app (or web interface) of your hub. +2. Tap the upper paddle on the switch 3 times quickly. + U.S. / Canada / Mexico + ZEN22 + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1946/zooz-z-wave-plus-dimmer-switch-zen22-manual.pdf + Zooz Z-Wave Dimmer Light Switch + FEATURES: +- Manual and wireless control from your smart phone or computer (when synced with a Z-Wave gateway controller) +- Direct 3-Way Solution: connects to an existing light switch for 2-point control, no special companion switch needed! (Neutral wire required, on/off control only from slave switch, use in 4-Way only if direct connection to load and line are in the same box) +- NEW IN VER. 3.0: Double tap to full brightness, fully adjustable ramp rate, scene control on select hubs, and more! +- White (no other color available) +- Extended LED bulb compatibility - works with most popular dimmable LED's (including Cree, Ecosmart, Philips, GE, Sylvania, Sunco, and others. NOT COMPATIBLE WITH LUMINUS BULBS.) +- Quick status reports to your hub when operated manually +- Based on universal command classes - supported by all certified Z-Wave gateway controllers +- Capable of advanced automation and association with other Z-Wave devices — schedule custom scenes and events +- Upgraded Z-Wave Plus 500 series chip for stronger and faster wireless connectivity +- Built-in signal repeater for a more reliable Z-Wave network +- Blue LED indicator to help locate the switch in the dark (now configurable straight from the switch!) +- Fits a standard-size face plate for single and multi gang installations (face plate not included) +- UL-listed and Z-Wave Plus certified + +SPECIFICATIONS: +- Model Number: ZEN22 + +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 120 VAC, 60 Hz +- Maximum Load: 500W Single-gang, 400W Double-gang, 300W Triple-gang Incandescent, 150W CFL or LED +- Range: Up to 100 feet line of sight +- Operating Temperature: 32-104° F (0-40° C) +- Installation and Use: Indoor only + +https://www.support.getzooz.com/kb/article/319-zooz-dimmer-zen22-ver-3-07-advanced-settings/ +MANUAL CONTROL +Upper Paddle: +1 x tap: load on to last / custom brightness; Scene 1, attribute 00 (button 1) +2 x tap: on to full / max brightness; Scene 1, attribute 03 (button 3) +3 x tap: enter inclusion (pairing) mode; Scene 1, attribute 04 (button 5) +4 x tap: Scene 1, attribute 05 (button 7) +6 x tap: change LED indicator mode (see parameter 2) +10 x tap: change physical / Z-Wave control mode (see parameter 15) +press and hold: increase brightness level +tap-tap-tap-and-hold: factory reset + +Lower Paddle: +1 x tap: load off; Scene 2, attribute 00 (button 2) +2 x tap: Scene 2, attribute 03 (button 4) +3 x tap: enter exclusion (unpairing) mode; Scene 2, attribute 04 (button 6) +4 x tap: Scene 2, attribute 05 (button 8) +press and hold: decrease brightness level +tap-tap-tap-and-hold: factory reset + + + Updated for firmware version 3.07 + + + + + + Normal mode: Upper paddle turns the light on, lower paddle turns the light off. Reverse mode: Upper paddle turns the light off, lower paddle turns the light on. Toggle mode: Either paddle toggles the light. + + + + + + LED Indication light function. Normal has the LED Indication on when the switch is off, off when the switch is on. + + + + + + + + + + + + Time, in minutes, for auto-off timer delay. + + + + + + + + Set the time (in minutes) after which you want the switch to automatically turn on once it has been turned off. + + + Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to associated devices. + + + + + + + + + + + + + + + + + + + Status after power failure. Off: always turn light off. On: always turn light on. Restore: remember the latest state and restore that state. + + + + + + Adjust the physical ramp rate for your dimmer (fade-in / fade-out effect for on / off operation). Values correspond to the number of seconds it take for the dimmer to reach full brightness or turn off when operated manually. This setting is for physical taps only, see parameter 17 to adjust Z-Wave ramp rate. Values: 1 – 99 (seconds). 0 – instant on/off. Default: 1 + + + Set the minimum brightness level (in %) for your dimmer. You won’t be able to dim the light below the set value. Default: 1 + + + Set the maximum brightness level (in %) for your dimmer. You won’t be able to add brightness to the light beyond the set value. Note: if Parameter 12 is set to value 0, Parameter 11 is automatically disabled. Default: 99 + + + Double Tap action. When set to Full, turns light on to 100%. If set to Maximum Level, turns light on to % set in Parameter 11. + + + + + Enable or Disable scene control functionality for quick double tap triggers. + + + + + Enables/Disables the double-tap function and assign brightness to single tap. Last level: single tap returns to last brightness level. Full/Max level: single tap returns to full/max level + + + + + + Enable or disable local on/off control. If enabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through paddles. + + + + + + Set the time it takes to get from 0% to 100% brightness when pressing and holding the paddle (physical dimming). The number entered as value corresponds to the number of seconds. Default: 4 + + + Choose if you want to set the Z-Wave ramp rate independently of the physical ramp rate (using an appropriate command in your hub) or if you want them to match. + + + + + Set the custom brightness level (instead of the last set brightness level) you want the dimmer to come on to when you single tap the upper paddle. Default: 0 - last brightness level + + + Choose the type of 3-way switch you want to use with this dimmer in a 3-way set-up. Changing this setting can allow you to control brightness and dim the light from both 3-way locations. Use a regular momentary switch (like the Zooz ZAC99 accessory switch) if value is set to 2. + + + + + + + Choose how you'd like the dimmer to report when paddles are tapped and held and physical / Z-Wave control is enabled or disabled. + + + + + Set reporting behavior for disabled physical control. + + + + + Set the brightness level the dimmer will turn on to when off and when lower paddle is held DOWN for a second. Default: 20 + + + + + + + + + + + diff --git a/openzwave/zooz/zen23.xml b/openzwave/zooz/zen23.xml new file mode 100644 index 00000000..8f35a046 --- /dev/null +++ b/openzwave/zooz/zen23.xml @@ -0,0 +1,19 @@ + + + + + + + Should the switch be inverted. Pressing down on the switch turns the load ON. + + + + + + + + + + + + diff --git a/openzwave/zooz/zen23v3.xml b/openzwave/zooz/zen23v3.xml new file mode 100644 index 00000000..8af76191 --- /dev/null +++ b/openzwave/zooz/zen23v3.xml @@ -0,0 +1,137 @@ + + + ZEN23 Toggle Switch V3 + Product features: +- Manual or remote on/off control from your mobile device or computer (when included to a Z-Wave gateway controller) +- Z-Wave Plus with improved 500 chip for faster and safer wireless communication +- Works with LED, CFL, and incandescent bulbs (minimum 15Watts on load required) +- Based on simple and universal binary switch command class - supported by most Z-Wave controllers +- May be associated and grouped with other Z-Wave devices for advanced home automation +- Built-in Z-Wave signal repeater for a stronger and more reliable network + +Specifications: +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 120 V, 60 Hz +- Maximum Load: 960W Incandescent, 150W LED and CFL bulbs, 1800W (15A) Resistive +- Range: Up to 100 feet line of sight +- Installation and Use: Indoor Only +- Operating Temperature: 32-104° F (0-40° C) +- Dimensions: 4 1/8" tall x 2 1/8" wide (with heat sink tabs,1 3/4" without the tabs) x 1 3/8" deep +- Weight: 10 oz + + +https://www.support.getzooz.com/kb/article/301-zen23-toggle-switch-change-log/ +https://www.support.getzooz.com/kb/article/317-zen23-on-off-toggle-switch-ver-3-05-advanced-settings/ +MANUAL CONTROL +Toggle Up: +1 x tap: load on; Scene 1, attribute 00 (button 1) +2 x tap: Scene 1, attribute 03 (button 3) +3 x tap: enter inclusion (pairing) mode; Scene 1, attribute 04 (button 5) +4 x tap: Scene 1, attribute 05 (button 7) +6 x tap: change LED indicator mode (see parameter 2) +10 x tap: change physical / Z-Wave control mode (see parameter 11) +tap-tap-tap-and-hold: factory reset + +Toggle Down: +1 x tap: load off; Scene 2, attribute 00 (button 2) +2 x tap: Scene 2, attribute 03 (button 4) +3 x tap: enter exclusion (unpairing) mode; Scene 2, attribute 04 (button 6) +4 x tap: Scene 2, attribute 05 (button 8) +tap-tap-tap-and-hold: factory reset + http://www.openzwave.com/device-database/027a:251c:b111 + http://getzooz.com/zooz-zen23-24-toggle-switch.html + https://www.support.getzooz.com/kb/tag/3/ + images/zooz/zen23v3.png + https://cdn.shopify.com/s/files/1/0218/7704/files/zooz-z-wave-plus-toggle-switch-zen23-ver3-manual.pdf?26 + 1. Initiate inclusion at your hub. 2. Toggle up 3 times very quickly at the switch. + 1. Put the Z-Wave hub into exclusion mode. 2. Toggle the switch down 3 times quickly. + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, toggle-toggle-toggle’n’hold down for at least 10 seconds. + U.S. / Canada / Mexico + ZEN23v3 + + Initial configuration from Zooz product help pages + + + + + + + Normal mode: Toggle up turns the light on, toggle down turns the light off. Reverse mode: Toggle up turns the light off, toggle down turns the light on. Toggle mode: Either direction toggles the light. + + + + + + Use this parameter to enable or disable the auto turn-off timer function. + + + + + Time, in minutes, for auto-off timer delay. + + + Use this parameter to enable or disable the auto turn-on timer function. + + + + + Set the time (in minutes) after which you want the switch to automatically turn on once it has been turned off. + + + Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to associated devices. + + + + + + + + + + + + + + + + + + + Status after Power Failure + + + + + + Enable or disable scene control functionality for quick double tap triggers. + + + + + Enable or disable manual on/off control. If enabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through the physical switch. + + + + + + Set reporting behavior for disabled physical control. + + + + + Choose the type of 3-way switch you want to use in a 3-way set-up. + + + + + + + + + + + + + + + diff --git a/openzwave/zooz/zen24.xml b/openzwave/zooz/zen24.xml new file mode 100644 index 00000000..36730ca7 --- /dev/null +++ b/openzwave/zooz/zen24.xml @@ -0,0 +1,18 @@ + + + + + + Should the switch be inverted. Pressing down on the switch turns the load ON. + + + + + + + + + + + + diff --git a/openzwave/zooz/zen24v2.xml b/openzwave/zooz/zen24v2.xml new file mode 100644 index 00000000..fb294384 --- /dev/null +++ b/openzwave/zooz/zen24v2.xml @@ -0,0 +1,180 @@ + + + ZEN24 Dimmer Switch V2 + Product features: +- Manual or remote on/off control and dimming from your mobile device or computer (when included to a Z-Wave gateway controller) +- Z-Wave Plus with improved 500 chip for faster and safer wireless communication +- Works with most high-quality DIMMABLE LED, CFL, and incandescent bulbs (20 Watts minimum required) +- Based on universal command classes - supported by most Z-Wave controllers +- May be associated and grouped with other Z-Wave devices for advanced home automation +- Air-gap switch to power the dimmer off when changing light bulbs +- Built-in Z-Wave signal repeater for a stronger and more reliable network + +Specifications: +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 120 V, 60 Hz +- Maximum Load: 500W Single-gang, 400W Double-gang, 300W Triple-gang Incandescent, 150W CFL or LED +- Range: Up to 100 feet line of sight +- Installation and Use: Indoor Only +- Operating Temperature: 32-104° F (0-40° C) +- Dimensions: 4 1/8" tall x 2 1/8" wide (with heat sink tabs,1 3/4" without the tabs) x 1 3/8" deep +- Weight: 10 oz + +https://www.support.getzooz.com/kb/article/298-zen24-toggle-dimmer-change-log/ +https://www.support.getzooz.com/kb/article/318-zen24-toggle-dimmer-ver-3-08-advanced-settings/ +MANUAL CONTROL +Toggle Up: +1 x tap: load on to last / custom brightness; Scene 1, attribute 00 (button 1) +2 x tap: on to full / max brightness; Scene 1, attribute 03 (button 3) +3 x tap: enter inclusion (pairing) mode; Scene 1, attribute 04 (button 5) +4 x tap: Scene 1, attribute 05 (button 7) +6 x tap: change LED indicator mode (see parameter 2) +10 x tap: change physical / Z-Wave control mode (see parameter 15) +press and hold: increase brightness level +tap-tap-tap-and-hold: factory reset + +Toggle Down: +1 x tap: load off; Scene 2, attribute 00 (button 2) +2 x tap: Scene 2, attribute 03 (button 4) +3 x tap: enter exclusion (unpairing) mode; Scene 2, attribute 04 (button 6) +4 x tap: Scene 2, attribute 05 (button 8) +press and hold: decrease brightness level +tap-tap-tap-and-hold: factory reset + http://www.openzwave.com/device-database/027a:261c:b112 + http://getzooz.com/zooz-zen23-24-toggle-switch.html + https://www.support.getzooz.com/kb/tag/4/ + images/zooz/zen24v2.png + https://cdn.shopify.com/s/files/1/0218/7704/files/zooz-z-wave-plus-toggle-dimmer-zen24-ver3-manual_889b0743-e025-445a-ac13-0f7742ba0675.pdf?100 + 1. Initiate inclusion at your hub. 2. Toggle up 3 times very quickly at the switch. + 1. Put the Z-Wave hub into exclusion mode. 2. Toggle the switch down 3 times quickly. + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, toggle-toggle-toggle’n’hold down for at least 10 seconds. + U.S. / Canada / Mexico + ZEN24v2 + + Initial configuration from Zooz product help pages + + + + + + + Normal mode: Toggle up turns the light on, toggle down turns the light off. Reverse mode: Toggle up turns the light off, toggle down turns the light on. Toggle mode: Either direction toggles the light. + + + + + + Use this parameter to enable or disable the auto turn-off timer function. + + + + + Time, in minutes, for auto-off timer delay. + + + Use this parameter to enable or disable the auto turn-on timer function. + + + + + Set the time (in minutes) after which you want the switch to automatically turn on once it has been turned off. + + + Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to associated devices. + + + + + + + + + + + + + + + + + + + Status after Power Failure + + + + + + Adjust the physical ramp rate for your dimmer (fade-in / fade-out effect for on / off operation). Values correspond to the number of seconds it take for the dimmer to reach full brightness or turn off when operated manually. This setting is for physical taps only, see parameter 17 to adjust Z-Wave ramp rate. Values: 1 – 99 (seconds). 0 – instant on/off. Default: 1 + + + Set the minimum brightness level (in %) for your dimmer. You won’t be able to dim the light below the set value. Default: 1 + + + Set the maximum brightness level (in %) for your dimmer. You won’t be able to add brightness to the light beyond the set value. Note: if Parameter 12 is set to value 0, Parameter 11 is automatically disabled. Default: 99 + + + Choose if you want the dimmer to turn on to full brightness or custom brightness level after you toggle the switch up twice quickly. + + + + + Enable or disable scene control functionality for quick double tap triggers. + + + + + Enable or disable the double tap function and assign brightness level to single tap. + + + + + + Enable or disable manual on/off control. If enabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through the physical switch. + + + + + + Set the time it takes to get from 0% to 100% brightness when pressing and holding the toggle (physical dimming). The number entered as value corresponds to the number of seconds. Default 4. + + + Choose if you want to set the Z-Wave ramp rate independently of the physical ramp rate (using an appropriate command in your hub) or if you want them to match. + + + + + Set the custom brightness level (instead of the last set brightness level) you want the dimmer to come on to when you toggle the switch up once. Default: 0 - last brightness level + + + Choose the type of 3-way switch you want to use with this dimmer in a 3-way set-up. Changing this setting can allow you to control brightness and dim the light from both 3-way locations. Use a regular momentary switch (like the Zooz ZAC99 accessory switch) if value is set to 2. + + + + + + + Choose how you'd like the dimmer to report when the toggle is held and physical / Z-Wave control is enabled or disabled. + + + + + Set reporting behavior for disabled physical control. + + + + + Set the brightness level the dimmer will turn on to when off and when lower paddle is held DOWN for a second. Default: 20 + + + + + + + + + + + + + diff --git a/openzwave/zooz/zen25.xml b/openzwave/zooz/zen25.xml new file mode 100644 index 00000000..1e80dccc --- /dev/null +++ b/openzwave/zooz/zen25.xml @@ -0,0 +1,96 @@ + + + + + + + Recovery state for the Double Plug's outlets if power outage occurs + + + + + + Minimum change in watts to report + + + How often to report power consumption (W) in seconds + + + How often to report energy usage (kWh)in seconds + + + How often to report voltage (V) in seconds + + + How often to report electrical current (A) in seconds + + + Turns off once amperage exceeds specified amount (both outlets combined) + + + + Enable (or disable) the auto turn-off timer for the left (CH1) outlet. See parameter 9 to set the amount of time. + + + + + Set the time (in minutes) to turn off the left (CH1) outlet if the Auto Turn-Off Timer - Left is enabled (see parameter 8). + + + Enable (or disable) the auto turn-on timer for the left (CH1) outlet. See parameter 11 to set the amount of time since the device was turned off before it turns back on. + + + + + Set the time (in minutes) to turn on the left (CH1) outlet after it is turned off. Requires the "Auto Turn-On Timer - Left" parameter (10) to be enabled. + + + Enable (or disable) the auto turn-off timer for the right (CH2) outlet. See parameter 13 to set the amount of time. + + + + + Set the time (in minutes) to turn off the right (CH2) outlet if the Auto Turn-Off Timer - Right is enabled (see parameter 12). + + + Enable (or disable) the auto turn-on timer for the right (CH2) outlet. See parameter 15 to set the amount of time since the device was turned off before it turns back on. + + + + + Set the time (in minutes) to turn on the right (CH2) outlet after it is turned off. Requires the "Auto Turn-On Timer - Right" parameter (14) to be enabled. + + + Enable (or disable) manual control of the outlets using the Z-Wave button on the double plug + + + + + Enable (or disable) LED indicators next to each outlet + + + + + + + Enable (or disable) power reports sent to the hub (requires firmware version 2 or higher) + + + + + + + + + + + + + + + + + diff --git a/openzwave/zooz/zen26.xml b/openzwave/zooz/zen26.xml new file mode 100644 index 00000000..891766d1 --- /dev/null +++ b/openzwave/zooz/zen26.xml @@ -0,0 +1,144 @@ + + + http://www.openzwave.com/device-database/027A:A001:A000 + images/zooz/zen26.png + https://products.z-wavealliance.org/products/3147/ + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, tap-tap-tap’n’hold the upper paddle for at least 10 seconds. The LED indicator will flash to confirm successful reset. +NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. + 1. Bring your Z-Wave gateway (hub) close to the switch if possible +2. Put the Z-Wave hub into exclusion mode (not sure how to do that? +ask@getzooz.com) +3. Tap the lower paddle on the switch 3 times quickly + 1. Initiate inclusion (pairing) in the app (or web interface) of your hub. +2. Tap the upper paddle on the switch 3 times quickly. + U.S. / Canada / Mexico + ZEN26 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3147/zooz-z-wave-plus-s2-on-off-switch-zen26-manual.pdf + S2 On Off Switch + FEATURES: +- Manual or Z-Wave on/off control with instant status updates +- Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed (neutral wire required) +- Remembers and restores on/off status after power failure +- LED indicator signals inclusion, exclusion, reset, and setting changes +- Built-in Z-Wave Plus signal repeater to extend network range +- Works with LED, CFL, and incandescent bulbs +- S2 security protocol and the latest 500 Z-Wave chip for faster and safer wireless communication +- Supported by most Z-Wave controllers + +SPECIFICATIONS: +- Model Number: ZEN26 +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 120 VAC, 60 Hz +- Maximum Load: 8 A, 150 W LED/CFL, 600 W incandescent, 1200 W resistive +- Range: Up to 100 feet line of sight +- Operating Temperature: 32-104° F (0-40° C) +- Installation and Use: Indoor only + +https://www.support.getzooz.com/kb/article/315-zooz-s2-on-off-switch-zen26-ver-2-03-advanced-settings/ +MANUAL CONTROL +Upper Paddle: +1 x tap: load on; Scene 1, attribute 00 (button 1) +2 x tap: Scene 1, attribute 03 (button 3) +3 x tap: enter inclusion (pairing) mode; Scene 1, attribute 04 (button 5) +4 x tap: Scene 1, attribute 05 (button 7) +6 x tap: change LED indicator mode (see parameter 2) +10 x tap: change physical / Z-Wave control mode (see parameter 11) +tap-tap-tap-and-hold: factory reset + +Lower Paddle: +1 x tap: load off; Scene 2, attribute 00 (button 2) +2 x tap: Scene 2, attribute 03 (button 4) +3 x tap: enter exclusion (unpairing) mode; Scene 2, attribute 04 (button 6) +4 x tap: Scene 2, attribute 05 (button 8) +tap-tap-tap-and-hold: factory reset + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3147/xml + Updated for firmware version 2.0 + Updated for firmware version 2.03 + + + + + + Normal mode: Upper paddle turns the light on, lower paddle turns the light off. Reverse mode: Upper paddle turns the light off, lower paddle turns the light on. Toggle mode: Either paddle toggles the light. + + + + + + LED Indication light function. Normal has the LED Indication on when the switch is off, off when the switch is on. + + + + + + + + + + + + Time, in minutes, for auto-off timer delay. + + + + + + + + Set the time (in minutes) after which you want the switch to automatically turn on once it has been turned off. + + + Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to associated devices. + + + + + + + + + + + + + + + + + + + Status after power failure. Off: always turn light off. On: always turn light on. Restore: remember the latest state and restore that state. + + + + + + Enable or Disable scene control functionality for quick double tap triggers (Available for select hubs only). + + + + + Enable or disable local on/off control. If enabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through paddles. + + + + + + Set reporting behavior for disabled physical control. + + + + + + + + + + + + diff --git a/openzwave/zooz/zen27.xml b/openzwave/zooz/zen27.xml new file mode 100644 index 00000000..ebdbe66c --- /dev/null +++ b/openzwave/zooz/zen27.xml @@ -0,0 +1,189 @@ + + + + http://www.openzwave.com/device-database/027a:a002:a000 + images/zooz/zen27.png + https://products.z-wavealliance.org/products/3148 + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, tap-tap-tap’n’hold the upper paddle for at least 10 seconds. The LED indicator will flash to confirm successful reset. + NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. + 1. Bring your Z-Wave gateway (hub) close to the switch if possible +2. Put the Z-Wave hub into exclusion mode (not sure how to do that? +ask@getzooz.com) +3. Tap the lower paddle on the switch 3 times quickly + 1. Initiate inclusion (pairing) in the app (or web interface) of your hub. 2. Tap the upper paddle on the switch 3 times quickly. + U.S. / Canada / Mexico + ZEN27 + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3148/zooz-z-wave-plus-s2-dimmer-switch-zen27-manual.pdf + S2 Dimmer + Product features: +- Manual or Z-Wave on/off and brightness control +- Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed (neutral wire required) +- Fully adjustable ramp rate for just the right on/off speed +- Double tap to full brightness feature +- Remembers and restores on/off status after power failure +- LED indicator signals inclusion, exclusion, reset, and setting changes +- Built-in Z-Wave Plus signal repeater to extend network range +- Extended compatibility with LED bulbs, no more flickering! +- S2 security protocol and the latest 500 Z-Wave chip for faster and safer wireless communication +- Customizable LED indicator and air-gap switch for added safety + +SPECIFICATIONS: +- Model Number: ZEN27 +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 120 VAC, 60 Hz +- Maximum Load: 100 W LED/CFL, 300 W incandescent (100 W with +both sides of heat sink tabs off) +- Range: Up to 100 feet line of sight +- Operating Temperature: 32-104° F (0-40° C) +- Installation and Use: Indoor only + +https://www.support.getzooz.com/kb/article/314-zooz-s2-dimmer-zen27-ver-2-08-advanced-settings/ +MANUAL CONTROL +Upper Paddle: +1 x tap: load on to last / custom brightness; Scene 1, attribute 00 (button 1) +2 x tap: on to full / max brightness; Scene 1, attribute 03 (button 3) +3 x tap: enter inclusion (pairing) mode; Scene 1, attribute 04 (button 5) +4 x tap: Scene 1, attribute 05 (button 7) +6 x tap: change LED indicator mode (see parameter 2) +10 x tap: change physical / Z-Wave control mode (see parameter 15) +press and hold: increase brightness level +tap-tap-tap-and-hold: factory reset + +Lower Paddle: +1 x tap: load off; Scene 2, attribute 00 (button 2) +2 x tap: Scene 2, attribute 03 (button 4) +3 x tap: enter exclusion (unpairing) mode; Scene 2, attribute 04 (button 6) +4 x tap: Scene 2, attribute 05 (button 8) +press and hold: decrease brightness level +tap-tap-tap-and-hold: factory reset + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3148/xml - this requires v2.0 (or newer) firmware + Updated for firmware version 2.08 + Updated for param 9 min value + + + + + + + + + Normal mode: Upper paddle turns the light on, lower paddle turns the light off. Reverse mode: Upper paddle turns the light off, lower paddle turns the light on. Toggle mode: Either paddle toggles the light. + + + + + + LED Indication light function. Normal has the LED Indication on when the switch is off, off when the switch is on. + + + + + + + + + + + + Time, in minutes, for auto-off timer delay. + + + + + + + + Set the time (in minutes) after which you want the switch to automatically turn on once it has been turned off. + + + Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to associated devices. + + + + + + + + + + + + + + + + + + + Status after power failure. Off: always turn light off. On: always turn light on. Restore: remember the latest state and restore that state. + + + + + + Adjust the physical ramp rate for your dimmer (fade-in / fade-out effect for on / off operation). Values correspond to the number of seconds it take for the dimmer to reach full brightness or turn off when operated manually. This setting is for physical taps only, see parameter 17 to adjust Z-Wave ramp rate. Values: 1 – 99 (seconds). 0 – instant on/off. Default: 1 + + + Set the minimum brightness level (in %) for your dimmer. You won't be able to dim the light below the set value. + + + Set the maximum brightness level (in %) for your dimmer. You won't be able to add brightness to the light beyond the set value. Note: if Parameter 12 is set to value "Full", Parameter 11 is automatically disabled. + + + Double Tap action. When set to Full, turns light on to 100%. If set to Maximum Level, turns light on to % set in Parameter 11. + + + + + Enable or Disable scene control functionality for quick double tap triggers. + + + + + Enables/Disables the double-tap function and assign brightness to single tap. Last level: single tap returns to last brightness level. Full/Max level: single tap returns to full/max level + + + + + + Enable or disable local on/off control. If enabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through paddles. + + + + + + Set the time it takes to get from 0% to 100% brightness when pressing and holding the paddle (physical dimming). The number entered as value corresponds to the number of seconds. Default: 4 + + + Choose if you want to set the Z-Wave ramp rate independently of the physical ramp rate (using an appropriate command in your hub) or if you want them to match. + + + + + Set the custom brightness level (instead of the last set brightness level) you want the dimmer to come on to when you single tap the upper paddle. Default: 0 - last brightness level + + + Choose how you'd like the dimmer to report when paddles are tapped and held and physical / Z-Wave control is enabled or disabled. + + + + + Set reporting behavior for disabled physical control. + + + + + Set the brightness level the dimmer will turn on to when off and when lower paddle is held DOWN for a second. Default: 20 + + + + + + + + + + + diff --git a/openzwave/zooz/zen30.xml b/openzwave/zooz/zen30.xml new file mode 100644 index 00000000..ff3add27 --- /dev/null +++ b/openzwave/zooz/zen30.xml @@ -0,0 +1,183 @@ + + + Double Switch + PRODUCT FEATURES: +- Manual or Z-Wave control of 2 separate loads (dimmer + relay) +- Perfect replacement for a fan / light combo (neutral wire required) +- Scene control for multi-tap scenarios on select hubs +- Quick and easy pigtail wire installation (single pole only) +- 4-color LED indicator and air-gap switch for added safety +- Fully customizable dimming features including ramp rate, on +brightness level, and double tap to full brightness +- Remembers and restores on/off status after power failure +- Built-in Z-Wave Plus signal repeater to extend network range +- S2 security protocol and 500 Z-Wave chip + +SPECIFICATIONS: +- Model Number: ZEN30 +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 120 VAC, 60 Hz +- Dimmer Max Load: 75 W LED, 250 W incandescent; DON’T use with tube lights, DC powered fixtures, or chandeliers +- Relay Max Load: 15 A (1/2 HP) +- Operating Temperature: 32-104° F (0-40° C) +- Installation and Use: Indoor only + + http://www.openzwave.com/device-database/027a:a008:a000 + http://www.getzooz.com/ + http://www.support.getzooz.com/kb/section/134 + images/zooz/zen30.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3791/zooz-s2-double-switch-zen30-ver1-manual-online.pdf + 1. Initiate inclusion (pairing) in the app (or web interface) of your hub. 2. Tap the upper paddle on the switch 3 times quickly. + 1. Bring your Z-Wave gateway (hub) close to the switch if possible. +2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com) +3. Tap the lower paddle on the switch 3 times quickly +4. Your hub will confirm exclusion and the device will disappear from your controller's device list + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, press and hold the lower paddle on the dimmer for at least 15 seconds until the LED indicators start flashing, then release. Then immediately press and hold the upper paddle on the dimmer for at least 15 seconds. The LED indicators will flash again to confirm successful reset. + https://products.z-wavealliance.org/products/3791 + U.S. / Canada / Mexico + ZEN30 + + Initial Metadata Import + Updated for firmware version 1.04 + + + + + + + LED Indicator Mode for Dimmer. Normal has the dimmer (top) LED indication on when the switch is off, off when the switch is on. Default: Normal + + + + + + + LED Indicator Mode for Relay. Normal has the relay (bottom) LED indication on when the switch is off, off when the switch is on. Default: Normal + + + + + + + LED Indicater color for Dimmer. White, Blue, Green or Red. Default: White + + + + + + + LED Indicater color for Relay. White, Blue, Green or Red. Default: White + + + + + + + LED Indicater Brightness for Dimmer. Bright (100%), Medium (60%) or Low (30%). Default: Medium + + + + + + LED Indicater Brightness for Relay. Bright (100%), Medium (60%) or Low (30%). Default: Medium + + + + + + LED Indicator Mode for Scene Control. Enable/Disable LED indicators next to the dimmer lighting up when a scene is selected. Default: disabled + + + + + Auto Turn-Off Timer for Dimmer. Sets the time (in minutes) after which you want the dimmer to automatically turn off once it has been turned on. Range: 1-65535. Default: 0 (disabled) + + + Auto Turn-On Timer for Dimmer. Sets the time (in minutes) after which you want the dimmer to automatically turn on once it has been turned off. Range: 1-65535. Default: 0 (disabled) + + + Auto Turn-Off Timer for Relay. Sets the time (in minutes) after which you want the relay to automatically turn off once it has been turned on. Range: 1-65535. Default: 0 (disabled) + + + Auto Turn-On Timer for Relay. Sets the time (in minutes) after which you want the relay to automatically turn on once it has been turned off. Range: 1-65535. Default: 0 (disabled) + + + On Off Status After Power Failure. Default: Restore both to prior state + + + + + + + + + + + + Ramp Rate Control for Dimmer. Adjust the ramp rate for your dimmer (fade-in / fade-out effect for on / off operation). Values correspond to the number of seconds it take for the dimmer to reach full brightness or turn off when operated manually. Note that 0 is instant. Default: 1 + + + Minimum Brightness. Set the minimum brightness level (in %) for your dimmer. You won't be able to dim the light below the set value. Default: 1 + + + Maximum Brightness. Set the maximum brightness level (in %) for your dimmer. You won't be able to add brightness to the light beyond the set value. Default: 99 + + + Double Tap Function for Dimmer. When set to full, turns light on to 100%. If set to maximum level, turns light on to % set in Parameter 15. Default: full + + + + + Enable/Disable Double-tap for Dimmer. Enables/Disables the double-tap fucntion and assign brightness to single tap. enabled: single tap turns on to maximum brightness level. disabled (last level): single tap returns to last brightness level. disabled (full/max level): single tap returns to full brightmess. Default: enabled + + + + + + Enable/Disable Load Control for Dimmer (Smart Bulb Setting). Enable or disable direct manual and Z-Wave control of the connected light (works great for smart bulb control). If disabled, the dimmer will no longer control the connected bulb directly but will still send on/off and brightness reports to the hub so you cn use them to create automations for your smart bulbs or other switches. Scenes and other functionality will still be available through the paddles. Default: manual disabled + + + + + + Enable/Disable Load Control for Relay (Smart Bulb Setting). Enable or disable direct manual and Z-Wave control of the connected light (works great for smart bulb control). If disabled, the relay will no longer control the connected bulb directly but will still send on/off and brightness reports to the hub so you cn use them to create automations for your smart bulbs or other switches. Scenes and other functionality will still be available through the paddles. Default: manual disabled + + + + + + Choose how many seconds it takes for the dimmer to go from 0% to 100% brightness when pressing and holding the paddle. Default: 4. + + + Default Brightness Level On for Dimmer. Set custom brightness level (in %) for the dimmer to come on to at single tap. Choose 0 for last brightness level. Default: 0. + + + Sets behavior of the dimmer when physical control is disabled + + + + + Sets behavior of the relay when physical control is disabled + + + + + Set the brightness level the dimmer will turn on to when off and when lower paddle is held DOWN for a second. Default: 20 + + + Normal mode: Upper paddle turns the light on, lower paddle turns the light off. Reverse mode: Upper paddle turns the light off, lower paddle turns the light on. Toggle mode: Either paddle toggles the light. + + + + + + + + + + + + + + + diff --git a/openzwave/zooz/zen31.xml b/openzwave/zooz/zen31.xml new file mode 100644 index 00000000..99d41766 --- /dev/null +++ b/openzwave/zooz/zen31.xml @@ -0,0 +1,206 @@ + + + RGBW Dimmer + FEATURES: +- Manual or Z-Wave on/off, brightness, and RGBW color control +- Perfect for programming your existing RGBW LED strip +- Energy monitoring in live mode and over time +- Double tap to full brightness feature + optional scene control +- Remembers and restores on/off status after power failure +- Built-in Z-Wave Plus signal repeater to extend network range +- S2 security protocol and AES-128 bank-grade encryption + +SPECIFICATIONS: +- Model Number: ZEN31 +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 12 / 24 V DC (Do NOT connect to 120 V AC high-voltage power!) +- Maximum Load: 10 A total between all channels (6 A per channel max); 120 W total when powered by 12 V DC / 240 W total when powered by 24 V DC +- Range: Up to 100 feet line of sight +- Operating Temperature: 32-104° F (0-40° C) +- Installation and Use: Indoor only +- Dimensions: 1.67” x 1.5” x 0.69” + http://www.openzwave.com/device-database/027a:2000:0902 + http://www.getzooz.com/ + http://www.support.getzooz.com/kb/section/135 + images/zooz/zen31.png + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3720/zooz-s2-rgbw-dimmer-zen31-manual-online.pdf + 1. Initiate inclusion (pairing) in the app (or web interface) of your hub. If you're using an S2 hub, it may ask you to enter the DSK key printed on the back cover sticker or scan the QR code next to it to complete secure inclusion. +2. Activate the dimmer. Make sure the RGBW Dimmer is powered up. Click the Z-Wave button 3 times quickly to include the device. The LED will blink yellow to indicate communication with the hub. It will blink green (for non-secure, S0, or S2 unauthenticated inclusion) or magenta (for S2 authenticated) once the device is successfully included to your network. It will blink red if inclusion is not successful. + 1. Bring your Z-Wave gateway (hub) close to the RGBW dimmer if possible. +2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com) +3. Click the Z-Wave button on the device 3 times quickly +4. Your hub will confirm exclusion, the LED indicator on the RGBW Dimmer will light up in red, and the device will disappear from your controller's device list. + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, press and hold the Z-Wave button to enter reset mode. Release the button when the LED indicator glows yellow. Then quickly click the Z-Wave button again to confirm factory reset. Wait a few seconds until the device resets and restarts - the LED indicator will light up in red when it's ready. + https://products.z-wavealliance.org/products/3720 + U.S. / Canada / Mexico + ZEN-31 + + Initial Metadata Import + + + + + + + + + On Off Status After Power Failure. Default: forced to OFF + + + + + + Switch / Input Type for IN1. Choose the input/switch type you want to connect to the IN1 terminal. Default: momentary switch + + + + + + + + Switch / Input Type for IN2. Choose the input/switch type you want to connect to the IN2 terminal. Default: momentary switch + + + + + + + + Switch / Input Type for IN3. Choose the input/switch type you want to connect to the IN3 terminal. Default: momentary switch + + + + + + + + Switch / Input Type for IN4. Choose the input/switch type you want to connect to the IN4 terminal. Default: momentary switch + + + + + + + + Assign scene activation trigger for IN1 terminal. Default: Everything + + + Click/toggle the connected switch 1 time to trigger a scene. + + + + Click/toggle the connected switch 2 times to trigger a scene. + + + + Click/toggle the connected switch 3 times to trigger a scene. + + + + Click/toggle the connected switch 4 times to trigger a scene. + + + + Assign scene activation trigger for IN2 terminal. Default: Everything + + + Click/toggle the connected switch 1 time to trigger a scene. + + + + Click/toggle the connected switch 2 times to trigger a scene. + + + + Click/toggle the connected switch 3 times to trigger a scene. + + + + Click/toggle the connected switch 4 times to trigger a scene. + + + + Assign scene activation trigger for IN3 terminal. Default: Everything + + + Click/toggle the connected switch 1 time to trigger a scene. + + + + Click/toggle the connected switch 2 times to trigger a scene. + + + + Click/toggle the connected switch 3 times to trigger a scene. + + + + Click/toggle the connected switch 4 times to trigger a scene. + + + + Assign scene activation trigger for IN4 terminal. Default: Everything + + + Click/toggle the connected switch 1 time to trigger a scene. + + + + Click/toggle the connected switch 2 times to trigger a scene. + + + + Click/toggle the connected switch 3 times to trigger a scene. + + + + Click/toggle the connected switch 4 times to trigger a scene. + + + + Power Report Frequency. Choose how often you want your RGBW Dimmer to report power consumption (W) to your controller. NOTE: must be 0, or an increment of 30. Default: 3600 + + + Energy Report Threshold. Choose how you want your RGBW Dimmer to report energy use (kWh) to your hub. The number entered as value corresponds to decimal values in energy useage change. So if 10 is entered by default, the RGBW Dimmer will report any change in energy use over 0.1 kWh. Energy reports are sent in t least 30-second intervals. + + + Energy Report Frequency. Choose how often you want your RGBW Dimmer to report energy (kWh) to your controller. NOTE: must be 0, or an increment of 30. Default: 3600 + + + RGBW/HSB Wall Switch Mode. Choose how switches connected to the input terminals control your LED strip. In the default RGBW mode, each switch connected to each input terminal controls the RGBW chnnels separately (so IN1 for red, IN2 for green, etc.) with a single click for ON/OFF, double click to full brightness, and press-and-hold to dim (momentary switches only). In the HSB, IN1 controls hue, IN2 - saturation, IN3 - brightness, IN4 - white with single click for last set value or value 0, double click to max value, and press-and-hold to set custom value. Default: RGBW mode + + + + + Ramp Rate (switch). Adjust the ramp rate for your RGBW dimmer (fade-in/fade-out effect for on/off operation). Values correspond to the number of seconds it takes for the dimmer to reach full brightness or turn off when operated from the connected wall switch. Note that 0 is instant on/off. Default : 3 seconds + + + Ramp Rate (Z-Wave). Adjust the ramp rate for your RGBW dimmer (fade-in/fade-out effect for on/off operation). Values correspond to the number of seconds it takes for the dimmer to reach full brightness or turn off when operated remotely from the Z-Wave hub Note that 0 is instant on/off. Default : 3 seconds + + + Enable one of the preset animated color programs to set the mood with a click. Default: preset programs disabled + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/zooz/zse08.xml b/openzwave/zooz/zse08.xml new file mode 100644 index 00000000..18c404bc --- /dev/null +++ b/openzwave/zooz/zse08.xml @@ -0,0 +1,24 @@ + + + + + + + + Set the delay time for turning associated devices OFF based on status change of your Contact Sensor, in seconds. 0 is default, which is instant. + + + You can choose if your Contact Sensor turns an associated device on or off when sending the basic command set. Value of 0 will set the associated device OFF and value 255 to turn it on. Value between 1 and 99 will be a percentage of light. Value between 100-254 are invalid. + + + + + + + + + + + + + diff --git a/openzwave/zooz/zse09.xml b/openzwave/zooz/zse09.xml new file mode 100644 index 00000000..b250b162 --- /dev/null +++ b/openzwave/zooz/zse09.xml @@ -0,0 +1,89 @@ + + + http://www.openzwave.com/device-database/027A:0083:0003 + images/zooz/zse09.png + https://products.z-wavealliance.org/products/1953/ + DMMS1 + If needed, the Motion Detector can be reset locally by following these steps. Only do this when your Z-Wave controller is disconnected or otherwise unreachable. Beware that resetting your device will disconnect it from the system: +1. Remove the SENSOR COVER and confirm that your Motion Detector is powered up. +2. Press and hold the BUTTON for at least 10 seconds then release. A flashing LED INDICATOR indicates a successful factory reset. +3. The Motion Detector’s memory will be erased to factory settings. + U.S. / Canada / Mexico + Follow the instructions for your Z-Wave Certified Conto enter exclusion mode. When prompted by the controller: +1. Remove the SENSOR COVER. +2. Press the BUTTON quickly 3 times in a row. +The LED INDICATOR will flash five times indicating exclusion/disconnection. + + The Dome™ Home Automation DMMS1 Z-Wave Certified Motion Detector tracks motion in your home, helping you keep your family safe. When motion is detected, your Z-Wave hub will send an alert to your smartphone, set off an alarm or trigger a lighting scene. This detector can also measure light levels to ensure the lights are operated only when required. Convenient magnetic mount offers the ultimate flexibility for multi surface adaptable installation on either wall, ceiling or table top. The device comes with a CR123A battery and has a 3-year battery life, so you can always be confident that your detector has power. Extra-long Z-Wave wireless range (up to 150 ft) allows you to place it where it’s needed without worrying if the signal reaching your Z-Wave Hub. The Dome™ Home Automation DMMS1 Z-Wave Certified Motion Detector comes with a 1-year limited warranty. Measurements in inches: 2.5 x 3.5 x 6. This sensor requires a Dome™ Home Automation Hub or other Z-Wave Certified hub for operation. The Dome™ Home Automation system gives your family the ease and security you can count on. With Dome™, you’re always connected and always covered. +● Detects movement inside your home with extra wide 110 deg. coverage and responds to activity by sending an alert to your smarthome system. Adjustable sensitivity for optimum performance based on environment +● Capable of sensing current light conditions in the room helping create smart lighting scenes. Adjustable timeout for selecting delay when lights will turn off after motion is no longer detected +● Convenient magnetic mount offering ultimate installation flexibility +● Z-Wave Plus Certified. Requires a Z-Wave Certified Hub to operate. Up to 150-foot range and 3-year battery life (CR123A Battery Included) +● Works with SmartThings, Vera, Staples Connect, HomeSeer, Nexia, Piper, URC, Harmony. Not supported: Wink, DSC, ADT Pulse, 2gig, Napco, Interlogix, Honeywell (Dome is not associated with listed brands) + + Dome Z-Wave Plus Motion Detector + Because the Motion Detector is a battery powered device, it wakes up on regular intervals to give battery and other status updates to the controller, as well as to accept configuration settings from the controller. This helps to extend the battery life. The device can be forced to wake up to submit these reports or accept new settings immediately by simply pressing and holding the BUTTON for two seconds. The LED INDICATOR will flash once indicating successful wake up. + Follow the instructions for your Z-Wave Certified Conto enter inclusion mode. When prompted by the controller: +1. The Motion Sensor should be within 10’ of your Z-Wave controller for the inclusion process. After successful pairing, the device can be brought to the desired location. +2. Remove the SENSOR COVER by twisting it counterclockwise. +3. Remove the BATTERY TAB. +4. Press the BUTTON quickly 3 times in a row. +5. The LED INDICATOR will flash five times indicating inclusion + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1953/Dome Motion Detector API Manual.pdf + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1938/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1953/xml + + + + + + + + Adjust motion detection sensitivity. Lower number is for higher sensitivity, while higher number os for lower sensitivity. Defaults to 12. + + + Set the duration you want the associated device to stay ON after being triggered by the sensor before it automatically turns OFF, in seconds. + + + Configure whether the Mini Sensor turns an associated device on or off when sending the BASIC_SET command. 0 is OFF, 255 is ON, and 1-99 is a percentage of light level. Value of 100-254 is NOT valid. + + + Enable or Disable motion detection. + + + + + Set light sensor as a secondary trigger for associated devices. If light level in a room falls beyond the set point and motion is detected, the Mini Sensor will send BASIC_SET command to associated devices to turn ON. + + + Adjust the time when motion is reported again after initial trigger, in seconds. + + + How often the Mini Sensor reports light level to the controller and associated devices, in seconds. + + + Enable/Disable the light sensor as secondary trigger. + + + + + Change required to report to the controller, in lux. + + + Enable or Disable LED Notification. + + + + + + + + + + + + + + diff --git a/openzwave/zooz/zse18.xml b/openzwave/zooz/zse18.xml new file mode 100644 index 00000000..eb2ef0b4 --- /dev/null +++ b/openzwave/zooz/zse18.xml @@ -0,0 +1,47 @@ + + + + + + + + Adjust PIR sensor sensitivity. 1-8; 1 is low sensitivity, 8 is high sensitivity Defaults to 4. + + + Enable or Disable BASIC SET reports when motion is triggered for Group 2 of associated devices. + + + + + Use it to reverse values sent in BASIC SET reports when motion is triggered for Group 2 of associated devices. Defaults to Disabled, which will send value 255 when motion is triggered and send value 0 when motion times out. Enabled will send value 0 when motion is triggered, and send value 255 when motion times out + + + + + Use it to set trigger interval - the time when motion is reported again after initial trigger. Values are between 3 and 65535 seconds, with a +3 second offset. Example; value of 3 actually means 6 seconds. Value of 27 actually means 30 seconds. Value of 65535 actually means 65538 seconds. Defaults to 27, so 30 seconds. NOTE: Small interval will increase activity and decrease battery life. + + + Enable or Disable vibration sensor. Enabled by default. + + + + + Use this to set battery level for low battery reports. value of 10 means 10% battery remaining, while value 50 means 50% battery remaining. Defaults to 10. + + + Enable or Disable LED indicator. Enabled by default. + + + + + + + + + + + + + + + diff --git a/openzwave/zooz/zse19.xml b/openzwave/zooz/zse19.xml new file mode 100644 index 00000000..cb551cd4 --- /dev/null +++ b/openzwave/zooz/zse19.xml @@ -0,0 +1,64 @@ + + + http://www.openzwave.com/device-database/027A:0003:000C + images/zooz/zse19.png + https://products.z-wavealliance.org/products/3116/ + S2 Multisiren + If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, make sure the Multisiren is powered, then CLICK-CLICK-CLICKCLICK’N’HOLD the Z-Wave button for AT LEAST 5 SECONDS. The LED indicator will flash to confirm successful reset. +NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. + 1. Bring the Multisiren within direct range of your Z-Wave gateway (hub). +2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com). +3. Click the Z-Wave button on the Multisiren 3 times quickly to finalize the process. +4. Your hub will confirm exclusion and the device will disappear from your controller's device list. + FEATURES: +- Audio and visual alarm triggered by other Z-Wave devices +- Configurable siren alarm duration +- Built-in temperature and humidity sensor (if Multilevel Sensor is supported) +- Audio Speaker for custom sound playback (if Sound Switch is supported) +- S2 security protocol and the latest 500 Z-Wave chip for faster and safer wireless communication +- Tamper protection, low-battery alerts + +SPECS: +- Model Number: ZSE19 +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 4 x LR14 (C Cell) battery +- Range: Up to 100 feet line of sight +- Operating Temperature: 14-104° F (-10-40° C) +- Operating Humidity: 0-80% +- Installation and Use: Indoor only + AUTO INCLUSION: +1. Initiate inclusion (pairing) in the app (or web interface). Not sure how? ask@getzooz.com +If you’re using an S2 hub, it may ask you to enter the DSK key printed on the back cover sticker to complete secure inclusion. + +2. Insert the batteries as instructed above (if you already did, take them out for at least 15 seconds before starting the inclusion process). The LED indicator will start blinking and the Multisiren will join the network automatically. + +MANUAL INCLUSION: +Put your Z-Wave hub into inclusion mode and click the Z-Wave button on the Multisiren 3 times quickly. + ZSE19 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3116/zooz-z-wave-plus-s2-multisiren-zse19-manual.pdf + U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3116/xml + + + + + + + + Siren Alarm Duration, in seconds. Defaults to 600 (10 minutes). + + + Reporting interval for temperature and humidity sensor, in miuntes. Defaults to 1440 (24 hours). + + + Selector for custom audio files that have been manually uploaded to the alarm unit. 0 sets to no sound (default), while 1-99 selects the sound file number in the library to be used. + + + + + + + + + diff --git a/openzwave/zooz/zse29.xml b/openzwave/zooz/zse29.xml new file mode 100644 index 00000000..b6a439e9 --- /dev/null +++ b/openzwave/zooz/zse29.xml @@ -0,0 +1,96 @@ + + + http://www.openzwave.com/device-database/027A:0005:0001 + images/zooz/zse29.png + https://products.z-wavealliance.org/products/3081/ + FEATURES: +- Quick and reliable motion alerts to Z-Wave hub +- Outdoor ready housing (avoid direct sun and rain) +- Set motion time-out and lux trigger at the sensor +- Auto-inclusion for easy set-up +- The latest S2 security and Z-Wave Plus chip +- Powered by common batteries or Micro USB +- Built-in tamper switch for extra security + +SPECS: +- Model Number: ZSE29 +- Z-Wave Signal Frequency: 908.42 MHz +- Power: 3 x AA (1.5 V) batteries / Micro USB +- Motion Detection: up to 30 feet +- Operating Temperature: -4 – 104 F +- Warm-up time: 1 minute +- Range: Up to 130 feet line of sight +- Installation and Use: Indoor / Outdoor + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3081/zooz-z-wave-plus-s2-outdoor-motion-sensor-zse29-manual.pdf + The sensor’s wake-up interval is set to 4 hours by default to save battery life. Use the Wake Up Command Class to adjust the interval (in seconds, working in 600s intervals, with 600 as min and 86400 as max values). +During wake-up, the sensor turns the Z-Wave radio on for 10 seconds to receive communication from the hub. Long wake-up interval will not affect how often the sensor reports motion to your hub. + Outdoor Motion Sensor + U.S. / Canada / Mexico + 1. Bring the sensor within direct range of your Z-Wave +gateway (hub). +2. Put the Z-Wave hub into exclusion mode (not sure +how to do that? ask@getzooz.com). +3. Press and release the tamper switch 3 times quickly. +4. Your hub will confirm exclusion and the sensor will +disappear from your controller's device list. + AUTO-INCLUSION: +1. Initiate inclusion (pairing) in the app (or web interface). Not Sure how? ask@getzooz.com. If you’re using an S2 hub, it may ask you to enter the DSK key printed on the back cover sticker to complete secure inclusion. +2. Insert the batteries or the USB adapter board. The LED indicator +will start blinking and the sensor will join the network Automatically. + +MANUAL INCLUSION: +Put your Z-Wave hub into inclusion mode and click the tamper switch 3 times quickly. + When your network’s primary controller is missing or otherwise inoperable, you may need to reset the device to factory settings manually. In order to complete the process, make sure the sensor is powered, then CLICKCLICK-CLICK-CLICK’N’HOLD the tamper switch for AT LEAST 5 SECONDS. The LED indicator will turn off to +indicate successful reset. The sensor will then enter auto-inclusion mode for 4 minutes. +NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. + ZSE29 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3081/xml + Updated for firmware version 2.0 + + + + + + + Set the value of basic set report sent to the light associated with the sensor in Group 2 (so the light turns on to the selected brightness level). 99 is the equivalent of full brightness in Z-Wave terms. + default: 99 + + + + Enable or disable motion reports completely. If motion sensor is disabled, the device will not report motion at all to your hub. + + + + + Adjust motion sensitivity where 10 is the most sensative setting. + default: 10 + + + + Set lux level trigger with 10 being the lowest reported value. The sensor will report motion to the hub and associated devices only if lux level is below the set value. + 0 - set manually by lux knob; (default) + 1 - ignore lux and always report motion; + + + + Set motion re-trigger time for the delay before the sensor reports no motion to the hub and associated devices after detecting the last motion activity. + 0 - set manually by timer knob; (default) + 5-720 (seconds) - set customer re-trigger time; + + + + Set lux reporting frequency to decide how often the snesor will measure and send brightness level data to the hub and associated devices. + default: 30 (minutes) + + + + + + + + + + + + diff --git a/openzwave/zooz/zse30.xml b/openzwave/zooz/zse30.xml new file mode 100644 index 00000000..9cdcd4dd --- /dev/null +++ b/openzwave/zooz/zse30.xml @@ -0,0 +1,116 @@ + + + http://www.openzwave.com/device-database/027A:0085:0003 + images/zooz/zse30.png + https://products.z-wavealliance.org/products/2204/ + ZSE30 + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2204/zooz-z-wave-plus-water-sensor-zse30-user-manual-online-v2.pdf + 1. Bring the Water Sensor within direct range of your controller +2. Carefully remove the cover from the sensor +3. Remove the plastic pull-tab from the battery slot. The LED indicator will blink slowly 5 times +4. Put your Z-Wave controller into inclusion mode +5. Press and release the Z-Wave button on the Water Sensor 3 TIMES quickly. The LED indicator + will flash quickly +6. A new water (leak) sensor will appear on your controller's device list + +Troubleshooting Tips +If you are unable to include the Z-Wave Water Sensor to your controller, try one of the following: +- Bring the sensor closer to your hub or use a hand-held secondary controller to perform inclusion +- Once in inclusion mode, press and release the Z-Wave button quickly 6-7 TIMES to ensure the command has gone through +- Put your controller in EXCLUSION mode. Press and release the Z-Wave button quickly 3 TIMES, and then try adding the sensor to your network again +- You may need to change the device type manually if the sensor is not recognized correctly (email us for more info: ask@getzooz.com) + + 1. Make sure the Water Sensor is powered on and located within direct range of your Z-Wave gateway controller +2. Put your Z-Wave controller in exclusion mode +3. Press and release the Z-Wave button 3 TIMES quickly. The LED indicator will flash quickly +4. The Water Sensor should disappear from your controller's device list +If the first attempt is unsuccessful, please repeat the process following all steps carefully. + + When your network’s primary controller is missing or otherwise inoperable, you may need to reset the device to factory settings manually. To complete the process, make sure the Water Sensor is powered on, then PRESS AND HOLD the Z-Wave button for AT LEAST 10 SECONDS until the LED indicator flashes ONCE. Release the button. NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. + Product features: +- Reliable water and leak detection +- Wireless notifications and event triggers (when included to a Z-Wave gateway controller) +- Built-in audio and visual alarms +- Low battery alerts +- Z-Wave Plus with improved 500 chip for faster and safer wireless communication +- Flexible installation with 2 mounting options + +Specifications: +Model Number: ZSE30 +Z-Wave Signal Frequency: 908.42 MHz +Power: 1 CR2 battery (included) +Power Consumption: 0.13W +Operating Temperature: 32 – 104 F +Range: Up to 100 feet line of sight +Installation and Use: Indoor only +Dimensions: 2.5” x 0.9” +Weight: 2 oz + U.S. / Canada / Mexico + Zooz Z-Wave Plus Water Sensor + If you change settings and parameters for the sensor, you may need to wake it up manually for the changes to be recorded. Press and release the Z-Wave button THREE TIMES to wake the device up. The LED indicator will flash ONCE. +The sensor’s wake-up interval is set to 12 hours by default to save battery life. Though not recommended, you can change the wake-up interval using your controller’s advanced settings if available. Minimum value: 300s (5 minutes), maximum value: 16,777,200s (around 194 days). Accepted values need to match minute intervals, so 300, 360, 420, etc. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2204/xml + + + + + + + + + + Use this parameter to set the total duration of audio and visual alarm each time water is detected. + If the value is set to 0, the alarm will continue until water is no longer detected. + + + + + Set the beeping frequency for the sensors audio alarm. + The interval between beeps can be as low as 1 minute. + + + + + Adjust the duration of the initial sound the alarm will produce after a leak is detected. + + + + + Adjust the duration of the beeps the alarm will sound after a leak is detected and the first "long" beep is produced. + + + + + Enable or disable the audio alarm by adjusting this parameter setting. + The visual alarm will NOT be disabled and the LED indicator will always light up each time water is detected + + + + + + + Enable or disable water detection for the sensor by adjusting this parameter setting.. + + + + + + + You can choose if your Water Sensor turns an associated device on or off when sending the basic set command. + Use value 0 to turn the associated device OFF and value 255 to turn it ON. + Adjust brightness level for a Z-Wave dimmer (Multilevel switch) by putting in any value between 1 and 99. + Values: 0 - OFF; 1 - 99 (% of light); 255 - ON (default). + + + + + + + + + + + + + diff --git a/openzwave/zooz/zse33.xml b/openzwave/zooz/zse33.xml new file mode 100644 index 00000000..8660bfb8 --- /dev/null +++ b/openzwave/zooz/zse33.xml @@ -0,0 +1,134 @@ + + + http://www.openzwave.com/device-database/027A:0088:0003 + images/zooz/zse33.png + https://products.z-wavealliance.org/products/2175/ + Zooz Z-Wave Plus Smart Chime + Auto Inclusion: +1. Put your Z-Wave controller in inclusion mode +2. Carefully remove the cover from the device +3. Remove the plastic pull-tab from the battery slot – the Chime will automatically enter inclusion mode for 20 seconds +4. A new alarm siren / doorbell device will appear on your controller's device list + +Manual Inclusion: +1. Bring the Smart Chime within direct range of your controller +2. Carefully remove the cover from the device +3. Remove the plastic pull-tab from the battery slot. The LED indicator will blink slowly +4. Put your Z-Wave controller in inclusion mode +5. Press and release the Z-Wave button on the Smart Chime 3 TIMES quickly. The LED indicator + will flash quickly +6. A new alarm siren / doorbell device will appear on your controller's device list (if it connects as an on/off switch, you may need to change the device type manually. Contact us for instructions). + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2175/zooz-z-wave-plus-smart-chime-zse33-user-manual-online.pdf + When your network’s primary controller is missing or otherwise inoperable, you may need to reset the device to factory settings manually. To complete the process, make sure the Smart Chime is powered on, then PRESS AND HOLD the Z-Wave button for AT LEAST 10 SECONDS until the LED indicator flashes ONCE. Release the button. NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. + Product features: +- Audio and visual notifications triggered by other Z-Wave devices or scheduled in your routine +- Choose from 10 different sounds for chime and siren modes +- Advanced configuration available +- Powerful long-lasting batteries +- Z-Wave Plus with improved 500 chip for faster and safer wireless communication +- Small size and quick installation + +Specifications: +Model Number: ZSE33 +Z-Wave Signal Frequency: 908.42 MHz +Power: 2 CR123 batteries (included) +Power Consumption: 2W +Operating Temperature: 32 – 104 F +Range: Up to 100 feet line of sight +Installation and Use: Indoor only +Dimensions: 2.7” x 1.2” +Weight: 3 oz + + 1. Make sure the Smart Chime is powered on and located within direct range of your Z-Wave gateway controller +2. Put your Z-Wave controller in exclusion mode +3. Press and release the Z-Wave button 3 TIMES quickly. The LED indicator will flash quickly +4. The Smart Chime should disappear from your controller's device list +If the first attempt is unsuccessful, please repeat the process following all steps carefully. + + U.S. / Canada / Mexico + Press and release the Z-Wave button three times. + ZSE33 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2175/xml + + + + + + + + + Siren volume level; low, medium, high (default). + + + + + + + + Duration of siren alarm. Default is 30 seconds. + + + + + + + + + + How many times the doorbell chime should repeat once triggered by a BASIC_SET alarm command from a door sensor. 0 is chime off, 1-254 is the number of cycles, 255 is chime continues until battery drains. 2 cycles is default. + + + + + Doorbell chime volume level; low, medium, high (default). + + + + + + + + Chose one of the 10 different tones for the alarm siren. 10 is default. + + + + + Chose one of the 10 different tones for the doorbell chime. 4 is default. + + + + + Choose between Siren Alarm (configured by Siren Alarm parameters) or Doorbell Chime (configured by Doorbell Chime paramenters). Doorbell Chime enabled by default. + + + + + + + Enable or disable visual LED alarm for Siren Mode. The LED will blink when triggered. Enabled by default. + + + + + + + Enable or disable visual LED for Doorbell Chime mode. The LED will blink when triggered. Enabled by default. + + + + + + + + + + + + + + diff --git a/openzwave/zooz/zse40.xml b/openzwave/zooz/zse40.xml new file mode 100644 index 00000000..691f73de --- /dev/null +++ b/openzwave/zooz/zse40.xml @@ -0,0 +1,96 @@ + + + http://www.openzwave.com/device-database/027A:2101:2021 + images/zooz/zse40.png + https://products.z-wavealliance.org/products/1804/ + To remove theZSE40 from the Z-Wave network (exclusion), place the Z-Wave primary controller into “exclusion” mode and follow its instruction to delete the ZSE40 to the controller. Press the Program Switch of ZSE40 once to be excluded. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1804/ZSE40-USER-MANUAL-5-13-16.pdf + ZSE40 + To add the ZSE40 to the Z-Wave network (inclusion), place the Z-Wave primary controller into inclusion mode. Press the Program Switch of ZSE40 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise, ZSE40 will go to sleep after 20 seconds. + Use “Wake Up” command to set up the awaking time (from 10 minutes to 1 week) and send the wake up notification to controller + 4-in-1 Sensor + Enjoy 4 smart sensors in 1 compact device. Monitor motion, temperature, humidity, and light level. +This is a secure device using 128-bit signal encryption. It requires a security enabled gateway controller for full functionality. +The Zooz 4-in-1 sensor is packed with advanced features: +- 7 levels of motion sensitivity to choose from +- 3 modes for motion / temp led indicator notifications +- Built-in tamper protection +- Low battery alerts +- Z-Wave Plus with improved 500 series chip for faster and safer wireless communication + +Z-Wave Frequency: 908.42 MHz (US) +Power: 2 AAA batteries +Wireless Range: Up to 100 feet line of sight +Operating Temperature: 5° - 104°F +Installation: Indoor Use Only +1 Year Warranty + U.S. / Canada / Mexico + Remove cover to trigged tamper switch, LED flash once & send out Alarm Report. Press Program Switch 10 times within 10 seconds, ZSE40 will send the “Device Reset Locally Notification” command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.) + + + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1804/xml + + + + + + + + + Temperature scale (Celsius or Fahrenheit (default)). + + + + + + + Minimum temperature change that will trigger a report to the controller, in 0.1 degrees. 10 = 1.0 degrees (default). + + + + + Minimum humidity change (%) that will trigger a report to the controller. 10 = 10% (default). + + + + + Minimum light sensor change (%) that will trigger a report to the controller. 10 = 10% (default). + + + + + After initial motion, sensor will wait this long before reporting again. 15 = 15 seconds (default); 60 = 60 seconds. + + + + + Motion sensor sensitivity. + + + + + + + + + + + + Color LED behavior. 1 = LED off; 2 = pulsing light for temperature, flashing light for motion (high battery drain); 3 = flashing light for temperature and motion (default); 4 = flashing light for motion. + + + + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/004001.xml b/openzwave/zwave.me/004001.xml new file mode 100644 index 00000000..d28f901e --- /dev/null +++ b/openzwave/zwave.me/004001.xml @@ -0,0 +1,30 @@ + + + http://www.openzwave.com/device-database/0115:0201:0100 + images/zwave.me/004001.png + https://products.z-wavealliance.org/products/1405/ + This products consists of a standard photo electric Smoke detector with a pluggable Z-Wave wireless interface module. +The Smoke detector will also work as a stand alone product and is certified by VDS according to EN 14604. The +smoke chamber of the detector has a stainless steel reel with antistatic plastic chamber. +A button allows on-device test of smoke chamber, electronics and battery. The device also offers a built-in self test and +an electronic smoke chamber test to avoid the use of test aerosol. A low battery warning will last for 30 days but full +function of the detector is guaranteed during this time. +The Z-Wave module allows to report the smoke and low battery alarm wirelessly to a central controller. The detector can +also be used as a wireless siren for alarm system or other applications. The wireless module is operated by the 9V battery +of the smoke detector. An optional external power supply allows external powering the unit. +According to VdS 3515 (Smoke Detectors with Wireless Communication) this device will send alarm signals to all other +smoke detectors registered in association group 2 to turn on their siren. This function ensures that all smoke detectors +will issue noise if one of them detected a smoke. + 004001 + To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5 +seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable. + Hit the little button on the wireless module for 1 second + Smoke Detector and Siren + Hit the little button on the wireless module for 1 second + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1405/004001_fixedmanual.docx + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1405/xml + + + diff --git a/openzwave/zwave.me/ZME_05431.xml b/openzwave/zwave.me/ZME_05431.xml new file mode 100644 index 00000000..43e76452 --- /dev/null +++ b/openzwave/zwave.me/ZME_05431.xml @@ -0,0 +1,116 @@ + + + http://www.openzwave.com/device-database/0115:0001:1000 + images/zwave.me/ZME_05431.png + https://products.z-wavealliance.org/products/20/ + ZME_06431 + http://www.pepper1.net/zwavedb/device/117 + This Z-Wave.Me switching Flush-Mountable is intended to control all kinds of electrical loads. A 230V powered pattress box is needed for installation. The Flush-Mountable has two buttons. In order to use them for local control the Flush-Mountable needs to be completed with a switching paddle and a mounting frame of one of the DUWI switching series “Everlux” or “Arcada”. + +Technical data of the hardware: +• Power rating: 230V, 50 Hz +• Wiring: 3-wire-system +• Maximum loads: 2300W +• Installation: in pattress box +• Distance: up to 30 m in buildings +• Display: Multicolour-LED +• Interaction: two buttons to be completed with switching paddle for local operation +• Power supply: via 230 V power +• Dimensions: 48mmx48mmx23mm + + Z-Wave.Me Flush-Mountable Switch + http://en.z-wave.me/content/z-wave-hardware + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/20/xml + + + + + + + + + + + + + + If not zero, automatically switch off/close blind after a user defined time + + + If not zero, automatically switch off/close blind after a user defined time + + + + + + + Defines if the dimmer shall ignore start level in StartLevelChange command despite it is specified or not. + + + + + Defines if the switch should restore switch state to the last state prior to device power off (power cycle). + + + + + Typical time used to differentiate click, hold, double and triple clicks. + + + + + + + If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only. + + + + + + Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. + + + + + + + + + Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands. + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/ZME_05461.xml b/openzwave/zwave.me/ZME_05461.xml new file mode 100644 index 00000000..4ceb239e --- /dev/null +++ b/openzwave/zwave.me/ZME_05461.xml @@ -0,0 +1,109 @@ + + + + + + + + + + + + + + If not zero, automatically switch first channel off after a user defined time + + + If not zero, automatically switch second channel off after a user defined time + + + Defines how to interpret RF first channel Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button + operations are not disabled). + + + + + + + + Defines how to interpret RF second channel Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button + operations are not disabled). + + + + + + + + Defines how to interpret button Down press. Depends on parameters 12 and 32 "Switch by buttons" parameter. If not Disabled this parameter will affect the action selected by the latter parameter. Can be used in conjunction with Auto Off function. + + + + + + Defines if the dimmer shall ignore start level in StartLevelChange command despite it is specified or not. + + + + + Defines if the switch should restore switch state to the last state prior to device power off (power cycle). + + + + + + + + + + + If disabled, the local operations by buttons will not switch relay on first channel, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only. + + + + + + If disabled, the local operations by buttons will not switch relay on second channel, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only. + + + + + + Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast. + + + + + + + Defines which command should be sent on button double press or press-hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands. + + + + + + + Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W. Disabled if zero. + + + Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W. Disabled if zero. + + + + + + + + + + + + diff --git a/openzwave/zwave.me/ZME_06433.xml b/openzwave/zwave.me/ZME_06433.xml new file mode 100644 index 00000000..b5f22ecb --- /dev/null +++ b/openzwave/zwave.me/ZME_06433.xml @@ -0,0 +1,150 @@ + + + http://www.openzwave.com/device-database/0115:0002:1000 + images/zwave.me/ZME_06433.png + https://products.z-wavealliance.org/products/19/ + CEPT (Europe) + This Z-Wave.Me dimming Flush-Mountable is intended to control lamps, both with resistive or inductive load. +A pattress box is needed for installation. The insert has two buttons. In order to use them for local control the Flush-Mountable needs to be completed with a switching paddle and a mounting frame of one of DUWIs switching series “Everlux” or “Arcada”. The device is a conventional leading-edge phase control dimmer with support for inductive loads such as transformers. Additionally conventional resistive loads such as incandescent lamps or 230 V halogen lamps can be dimmed as well. + + +Technical Data: +• Power rating: 230V, 50 Hz +• Wiring: 2-wire-system +• Maximum loads: +  - Incandescent lamps: 40...300W +  - 230V (HV) halogen: 40...300W +  - Low voltage halogen with standard transformer (inductive load): 30...300VA +  - Low voltage halogen with switched power supply (reactive load): no +  - Fluorescent light: 30…300VA, only dimmable lamps +• Installation: in pattress box +• Distance: up to 30 m in buildings +• Display: Multicolour-LED +• Interaction: two buttons to be completed with switching paddle for local operation +• Power supply: via 230 V power +• Dimensions: 48mmx48mmx23mm + http://www.pepper1.net/zwavedb/device/122 + http://en.z-wave.me/content/z-wave-hardware + Z-Wave.Me Flush-Mountable Dimmer + ZME_06433 + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/19/xml + + + + + + + + + + + + + If not zero, automatically switch off after a user defined time + + + Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled). + + + + + + + Defines if the dimmer shall ignore start level in StartLevelChange command despite it is specified or not. + + + + + Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserve bulb life. + + + Time to dim on button holds and StartLevel Change command (if it has no duration specified). + + + Defines if the dimmer shall set maximum light level on On command. By default on On command dimmer restores last level. This parameter allows to configure to set maximum level on second On command (if already On) or to always switch on to maximum level. + + + + + + Time to dim on double click Off button for Baby- Dim function. This function works only if the load is operated by single press and hold button action. If enabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands, unprotected. + + + Target level on which to stop while executing Baby Dimming. Can be 0 to completely switch off the light. + + + Typical time used to differentiate click, hold, double and triple clicks. + + + + + + + If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only. + + + + + + Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast. + + + + + + + + + Defines which command should be sent on button double press or press-hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands. + + + + + + + + + + + + + + + Maximum level should be greater than minimal level. Set to 0 to work as a switch (off or full on only), or set to 10 - 99 + + + Set to 0 to use previous light level, or set to 1 - 99 + + + NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 1. For other bulbs use default value. + + + NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 40. For other bulbs use default value. + + + NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 20. For other bulbs use default value. + + + NB: Do not touch these settings if you are not sure what they mean! + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/ZME_06436.xml b/openzwave/zwave.me/ZME_06436.xml new file mode 100644 index 00000000..05091c11 --- /dev/null +++ b/openzwave/zwave.me/ZME_06436.xml @@ -0,0 +1,120 @@ + + + http://www.openzwave.com/device-database/0115:0003:1000 + images/zwave.me/ZME_06436.png + https://products.z-wavealliance.org/products/583/ + ZME_05436 + This Z-Wave.Me switching Flush-Mountable is intended to control window or door blinds. +A 230V powered pattress box is needed for installation. The Flush-Mountable has two buttons. +In order to use them for local control the insert needs to be completed with a switching paddle and a mounting frame of one of the DUWI switching series “Everlux” or “Arcada”. + +Technical Data: +• Power rating: 230V, 50 Hz +• Switched load: up to 1800W motor +• Outputs: 2 switches interlocked against each other +• Duration of switching signal: 2 min. +• Local interaction: 2 buttons for inclusion, exclusion and association +• Dimensions: 48mmx52mmx27mm +• Power supply: via 230 V power +• Distance: up to 100 m outdoor, up to 30 m within buildings + + http://www.pepper1.net/zwavedb/device/119 + http://en.z-wave.me/content/z-wave-hardware + CEPT (Europe) + Z-Wave.Me - Flush Mountable Blind Control + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/583/xml + + + + + + + + + + + + + + If not zero, automatically switch off/close blind after a user defined time + + + If not zero, automatically switch off/close blind after a user defined time + + + + + + Time to go from opened to closed state. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close. + + + Time to go from closed to open state. This value may differ from Full close time for some blinds due to gravity. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close. + + + Id of the device which commands would be interpreted not as Open/Close, but as block/unblock. Usefull with door opening detector: if the door is open, block the blind not to break shades while they move. + + + Defines which command from blocking device to interpret as closed door and hence, unprotected. + + + + + Defines behaviour on open press while closing and vice versa. To allow Stop behavior when switched by remote, use Stop by Basic + + + + + + Allow exchanging open and close relays if blind control is wired to the motor incorrectly + + + + + Typical time used to differentiate click, hold, double and triple clicks. + + + + + + + If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only. + + + + + + Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. + + + + + + Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands. + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/ZME_064381.xml b/openzwave/zwave.me/ZME_064381.xml new file mode 100644 index 00000000..cd0f3b12 --- /dev/null +++ b/openzwave/zwave.me/ZME_064381.xml @@ -0,0 +1,58 @@ + + + + + + + Set LED indication mode + + + + + + If not zero, automatically switch device off after an user defined time. Unit: Sec, Min: 0, Max: 65535, Default: 0 + + + Defines how to interpret RF Off-Command. + Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; + Switch on - to switch on the light on both ON and OFF paddle press on the remote and switch it off after some amount of time. + Button OFF click will still work (if button operations are not disabled). + + + + + + + + Defines if the switch should restore switch state to the last prior to device power off (power cycle). + + + + + Specify the consumption of the load in watts, for the calculation of power consumption. Maximum load 1800 W. Unit: Watts, Min: 0, Max: 3500, Default: 0 + + + Color to OFF state + + + + + + + + Color to ON state + + + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/ZME_064435.xml b/openzwave/zwave.me/ZME_064435.xml new file mode 100644 index 00000000..393e1ece --- /dev/null +++ b/openzwave/zwave.me/ZME_064435.xml @@ -0,0 +1,59 @@ + + + + + + + + Typical time used to differentiate click, hold, double and triple clicks Values: 1 to 100 in 10 ms units (default is 50, that is equivalent to 500 ms) + + + + + + + Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. + + + + + + + Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands. + + + + + + + + + + + + Send unsolicited battery report on wakeup. + + + + + + + + + true + + + + + + false + + + + + + + + + + diff --git a/openzwave/zwave.me/ZME_KFOB-S.xml b/openzwave/zwave.me/ZME_KFOB-S.xml new file mode 100644 index 00000000..13ac4b16 --- /dev/null +++ b/openzwave/zwave.me/ZME_KFOB-S.xml @@ -0,0 +1,116 @@ + + + + + + In separate mode button 1 works with group A, button 3 with groups C. + Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. + In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C. + + + + + + In separate mode button 2 works with group B, button 4 with groups D. + Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. + In pair button 2/4 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D. + + + + + + This parameter defines the command to be sent to devices of control group A when the related button is pressed + + + + + + + + + + + + This parameter defines the command to be sent to devices of control group B when the related button is pressed + + + + + + + + + + + + This parameter defines the command to be sent to devices of control group C when the related button is pressed + + + + + + + + + + + + This parameter defines the command to be sent to devices of control group D when the related button is pressed + + + + + + + + + + + + Send the following Switch All ON/OFF commands + + + + + + Invert meaning of On/Dim up and Off/Dim down in pairs of buttons. This applies only to pairs in grouped mode. Buttons 1 and 2 will become Off/Dim down, buttons 3 and 4 On/Dim up. + + + + + If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery + + + + + + + + + + + + + + false + + + + + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/ZME_RC2.xml b/openzwave/zwave.me/ZME_RC2.xml new file mode 100644 index 00000000..987c9f7f --- /dev/null +++ b/openzwave/zwave.me/ZME_RC2.xml @@ -0,0 +1,143 @@ + + + + + + + + This parameter defines the command to be sent to devices of control group No1 when the related button is pressed (association group 2) + + + + + + + + + This parameter defines the command to be sent to devices of control group No2 when the related button is pressed (association group 3) + + + + + + + + + This parameter defines the command to be sent to devices of control group No3 when the related button is pressed (association group 4) + + + + + + + + + This parameter defines the command to be sent to devices of control group No4 when the related button is pressed (association group 5) + + + + + + + + + This parameter defines the command to be sent to devices of control group No5 when the related button is pressed (association group 6) + + + + + + + + + This parameter defines the command to be sent to devices of control group No6 when the related button is pressed (association group 7) + + + + + + + + + This parameter defines the command to be sent to devices of control group No7 when the related button is pressed (association group 8) + + + + + + + + + This parameter defines the command to be sent to devices of control scene group No1 when the related button is pressed (association group 9) + + + + + + + + + This parameter defines the command to be sent to devices of control scene group No2 when the related button is pressed (association group 10) + + + + + + + + + This parameter defines the command to be sent to devices of control scene group No3 when the related button is pressed (association group 11) + + + + + + + + + This parameter defines the command to be sent to devices of control group All On/Off when the related button is pressed (association group 12) + + + + + + + + + Send the following Switch All ON/OFF commands + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/ZME_WALLC-S.xml b/openzwave/zwave.me/ZME_WALLC-S.xml new file mode 100644 index 00000000..61038091 --- /dev/null +++ b/openzwave/zwave.me/ZME_WALLC-S.xml @@ -0,0 +1,97 @@ + + + + + + + + + In separate mode button 1 works with group A, button 3 with groups C. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C. + + + + + + In separate mode button 2 works with control group B, button 4 with control group D. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button B/D are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D. + + + + + + This parameter defines the command to be sent to devices of control group A when the related button is pressed + + + + + + + + + + + This parameter defines the command to be sent to devices of control group B when the related button is pressed + + + + + + + + + + + This parameter defines the command to be sent to devices of control group C when the related button is pressed + + + + + + + + + + + This parameter defines the command to be sent to devices of control group D when the related button is pressed + + + + + + + + + + + + + + + + + + + + If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/ZME_WCD2.xml b/openzwave/zwave.me/ZME_WCD2.xml new file mode 100644 index 00000000..74ae66dd --- /dev/null +++ b/openzwave/zwave.me/ZME_WCD2.xml @@ -0,0 +1,138 @@ + + + + + + + Button 1 and 3 pair mode (Parameter Number 1, + Parameter Size 1) In separate mode button 1 works + with group 1, button 3 with groups 3. Click is On, Hold + is dimming Up, Double click is Off, Click-Hold is + dimming Down. In pair button 1/3 are Up/Down + correspondingly. Click is On/Off, Hold is dimming + Up/Down. Single clicks works with group 1, double click with group + 3. + + + + + + Button 2 and 4 pair mode (Parameter Number 2, + Parameter Size 1) In separate mode button 2 works + with group 2, button 4 with groups 4. Click is On, Hold + is dimming Up, Double click is Off, Click-Hold is + dimming Down. In pair button 2/4 are Up/Down + correspondingly. Click is On/Off, Hold is dimming + Up/Down. Single clicks works with group 2, double click with group 4. + + + + + + + Action on group 1 (Parameter Number 11, + Parameter Size 1) In Switch On/Off only mode On + command is sent on Dim Up, Off on Dim Down. In Scenes mode the + scene ID sent is (10 * group + ActionID), where + ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = + Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop + + + + + + + + + + Action on group 2 (Parameter Number 12, + Parameter Size 1) In Switch On/Off only mode On + command is sent on Dim Up, Off on Dim Down. In Scenes mode the + scene ID sent is (10 * group + ActionID), where + ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = + Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop + + + + + + + + + + Action on group 3 (Parameter Number 13, + Parameter Size 1) In Switch On/Off only mode On + command is sent on Dim Up, Off on Dim Down. In Scenes mode the + scene ID sent is (10 * group + ActionID), where + ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = + Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop + + + + + + + + + + Action on group 4 (Parameter Number 14, + Parameter Size 1) In Switch On/Off only mode On + command is sent on Dim Up, Off on Dim Down. In Scenes mode the + scene ID sent is (10 * group + ActionID), where + ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = + Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop + + + + + + + + + + Typical time used to differenciate click, hold and double clicks + + + + + + + + + + + + This allows to save battery + + + + + + + + + + + + + false + + + + + + + + + + + + diff --git a/openzwave/zwave.me/ZUno.xml b/openzwave/zwave.me/ZUno.xml new file mode 100644 index 00000000..c7cf6990 --- /dev/null +++ b/openzwave/zwave.me/ZUno.xml @@ -0,0 +1,63 @@ + + + http://www.openzwave.com/device-database/0115:0001:0110 + images/zwave.me/ZUno.png + https://products.z-wavealliance.org/products/1825/ + Hold Service button for five seconds, then press Service button three times. + +Use this procedure only if your controller is missing or inoperable. + +Note that the user sketch is not erased during exclusion or reset process. + Press Service button three times + Press Service button three times + Z-Uno + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1825/Z-Uno V3 Manual.pdf + v3 + Press Service button three times + CEPT (Europe) + Z-Uno is the first and only easy to use developer board that allows you to create your own Z-Wave device without deep knowledge of Z-Wave protocol or programming. Z-Uno is a mix of Z-Wave home automation radio protocol power and Arduino simplicity. Being inspired by Arduino project Z-Uno inherits all concepts of easy-to-use hardware and software solutions, keeping maximum flexibility. + +Z-Uno is a fully DIY product. It is made for those who are limited by existing choice of Z-Wave products and wants to extend their smart homes with more sensors and actuators: connect LEDs, buttons, switches, motors or any low voltage sensor including most of Arduino compatible sensors. + +Z-Uno programming is done by writing sketch in simplified C language and loaded into Z-Uno using Arduino IDE. Many examples and comprehensive tutorials will help you to make your own project. + +This is one of the two officially certified sketches. + +Certified 10 Channels sketch +http://z-uno.z-wave.me/examples/Certified10Channels/ + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1825/xml + + + + + + + Debug mode to apply channels, associations and power mode changes on the fly without exclusion-inclusion sequence. Use for debugging only! + + + + + Blink with service LED during operation + + + + + + + true + + + + + true + + + + + + + + + + diff --git a/openzwave/zwave.me/iTemp.xml b/openzwave/zwave.me/iTemp.xml new file mode 100644 index 00000000..60663513 --- /dev/null +++ b/openzwave/zwave.me/iTemp.xml @@ -0,0 +1,35 @@ + + + + 0 + + + + + + Reset but keep on network + + + + + Report type on group 1 + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/kfob.xml b/openzwave/zwave.me/kfob.xml new file mode 100644 index 00000000..f296df10 --- /dev/null +++ b/openzwave/zwave.me/kfob.xml @@ -0,0 +1,132 @@ + + + http://www.openzwave.com/device-database/0115:0001:0100 + images/zwave.me/kfob.png + https://products.z-wavealliance.org/products/688/ + KFOB + The Z-Wave.Me Key Fob is a mobile Z-Wave device that can both control other Z-Wave devices and activate predefined scenes in an IP gateway. + +The Key Fob can be used in five different modes: +1) Direct Control of associated Devices with single Buttons +2) Direct Control of associated Devices with two Buttons +3) Scene Activation in IP Gateway +4) Direct Activation of preconfigured Scenes +5) Direct Control of Devices in proximity
 + + Z-Wave.Me Key Fob + Russia + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/688/xml + + + + + + In separate mode button 1 works with group 1, button 3 with groups 3. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group 1, double click with group 3. + + + + + + In separate mode button 2 works with group 2, button 4 with groups 4. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 2/4 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group 2, double click with group 4. + + + + + + In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop + + + + + + + + + + In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop + + + + + + + + + + In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop + + + + + + + + + + In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop + + + + + + + + + + Typical time used to differentiate click, hold and double clicks 1-100 in 10 ms units (default is 50, that is equivalent to 500 ms) + + + Send the following Switch All ON/OFF commands + + + + + + Invert meaning of On/Dim up and Off/Dim down in pairs of buttons. This applies only to pairs in grouped mode. Buttons 1 and 2 will become Off/Dim down, buttons 3 and 4 On/Dim up. + + + + + To save batteries LED confirmation can be disabled. + + + + + + + If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery + + + + + + + + + + + + + + false + + + + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/popp_kfob-c.xml b/openzwave/zwave.me/popp_kfob-c.xml new file mode 100644 index 00000000..cc035db7 --- /dev/null +++ b/openzwave/zwave.me/popp_kfob-c.xml @@ -0,0 +1,140 @@ + + + http://www.openzwave.com/device-database/0115:0103:0100 + images/zwave.me/popp_kfob-c.png + https://products.z-wavealliance.org/products/1282/ + When in factory default push Button 3 (secure) or Button 4 (normal) for one second to enter inclusion mode. The inclusion mode is indicated by a blinking green LED. From second device on you need to enter management mode push all four buttons together for one second - green led blinks slowly), hit button 3 ( enter primary controller functions - green led blinks faster) and then button 1 (secure) or button 2 (normal). + Enter management mode by push all four buttons together for one second - green led blinks slowly), hit button 3 ( enter primary controller functions - green led blinks faster) and then button 3 again. + + + Enter management mode by push all four buttons together for one second - green led blinks slowly), then hit button 2 . + CEPT (Europe) + Secure Key Chain Controller + ZME_KFOBC + Enter management mode by push all four buttons together for one second - green led blinks slowly), then hit button 3 followed by keeping button 4 pushed down for 10 seconds. The first five seconds the green LED still blinks followed by a long red, shot green sequence. Once LEDs go off, reset was executed. Please use this +procedure only if the device is secondary controller and the primary controller is missing or otherwise inoperable. + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1282/ZMEEKFOBC_Manualfinal.pdf + The Secure Key Fob Controller is a 4 button Z-Wave device capable to act both as primary or secondary controller. The four buttons can control other Z-Wave devices such as switches, dimmer and even door locks directly. Various options - configurable by Z-Wave configuration commands - define the actions and the commands used for this control. It is possible to use two sets of buttons (one of on/open/up and one for off/closed/down) or 4 single buttons to control 4 different groups of devices. + +The controller also allows triggering scenes in a central controller. Again different modes can be configured to adapt to the various implementations of scenes in different central controllers in the market. + +Control options also include special modes like 'all on/off' or always controlling the Z-Wave device in proximity to the fob. The device supports secure communication when included with enhanced security option and when communicating to a device also supporting enhanced security option. Otherwise the device will automatically turn into normal communication. to maintain backward compatibility. + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1282/xml + + + + + + + In separate mode button 1 works with group A, button 3 with groups C. + Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. + In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C. + + + + + + In separate mode button 2 works with group B, button 4 with groups D. + Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. + In pair button 2/4 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D. + + + + + + This parameter defines the command to be sent to devices of control group A when the related button is pressed + + + + + + + + + + + + This parameter defines the command to be sent to devices of control group B when the related button is pressed + + + + + + + + + + + + This parameter defines the command to be sent to devices of control group C when the related button is pressed + + + + + + + + + + + + This parameter defines the command to be sent to devices of control group D when the related button is pressed + + + + + + + + + + + + Send the following Switch All ON/OFF commands + + + + + + Invert meaning of On/Dim up and Off/Dim down in pairs of buttons. This applies only to pairs in grouped mode. Buttons 1 and 2 will become Off/Dim down, buttons 3 and 4 On/Dim up. + + + + + If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery + + + + + + + + + + + + + + false + + + + + + + + + + + + + + + + + diff --git a/openzwave/zwave.me/razberry.xml b/openzwave/zwave.me/razberry.xml new file mode 100644 index 00000000..0d9b4048 --- /dev/null +++ b/openzwave/zwave.me/razberry.xml @@ -0,0 +1,8 @@ + + + images/zwave.me/razberry.png + + Initial metadata to add pic + + + diff --git a/openzwave/zwave.me/zme_raz5.xml b/openzwave/zwave.me/zme_raz5.xml new file mode 100644 index 00000000..b1e5afcd --- /dev/null +++ b/openzwave/zwave.me/zme_raz5.xml @@ -0,0 +1,28 @@ + + + http://www.openzwave.com/device-database/0115:0001:0001 + images/zwave.me/zme_raz5.png + https://products.z-wavealliance.org/products/1260/ + n/a + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1260/RaZberryEndUserManual.pdf + Web Interface; Network Tab, "Exclude Device" + ZMEURAZ5 + Razberry500 + The RaZberry solution turns every Raspberry PI micro computer into an Z-Wave based Smart Home Gateway. The backend can support Z-Wave but other third party communication technologies. An embedded web server with an Z-Wave expert UI allows easy configuration and use. The embedded Apple HomeKit server bridges Z-Wave devices into the Apple smart home world. The real power of the solution is an very user friendly API and Javascript based logic engine to enable users to write their own customized solution und user experience. + +The RaZberry consists of various parts: + +(a) Z-Wave transceiver pluggable to the GPIO interface of the Raspberry PI, +(b) A Z-Wave stack integrated into an open source Javascript based smart home +automation engine +(c) Various user interfaces including an AJAX based Web UI, Apple HomeKit server +and several IOS and Android Apps. + Web Interface; Network Tab, "Reset Controller" + Web Interface; Network Tab, "Include Device" + CEPT (Europe) / U.S. / Canada / Mexico + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1150/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1260/xml + + + diff --git a/openzwave/zwave.me/zweather.xml b/openzwave/zwave.me/zweather.xml new file mode 100644 index 00000000..36079e9d --- /dev/null +++ b/openzwave/zwave.me/zweather.xml @@ -0,0 +1,54 @@ + + + http://www.openzwave.com/device-database/0115:0400:0100 + images/zwave.me/zweather.png + https://products.z-wavealliance.org/products/1424/ + Push the button 3 times within 1.5 seconds. If the LED is not blinking after releasing the button, Z-Weather has not enough energy and must be charged for several hours in bright sunlight. + + Push the button 3 times within 1.5 seconds. The LED blinks once indicating that Z-Weather is. Z-Weather sends a Z-Wave Wakeup-Notification if has been added to the network. If Z-Weather has not yet been added to the network, no action is performed. + ZWeather + Z-Weather + Push the button 3 times within 1.5 seconds. + Z-Weather is a multisensor device monitoring outside weather and environmental conditions. It continually measures the wind speed and can, for example, trigger closing of the awning and blinds if it is too windy. It also measures the amount of rotation, enabling calculation of the wind yield per day or per year. In addition, Z-Weather includes sensors for humidity, temperature, pressure and dew point, essentially providing the core sensors of a weather station. +Z-Weather is powered by a solar cell and stores energy on an internal capacitor, enabling continuous operation, even with no wind for a couple of days. It does not use any batteries and is completely maintenance free. Using the built-in solar cell it also measures the ambient light and the solar yield. This information can be used to turn on the outdoor light at dusk time and turn the light off in the morning. +Z-Weather‘s wind yield and solar yield metering can be used as a calculation base for planning a wind generator or a solar panel on the roof of a house. + + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1424/Z-Weather Manual_v1.3.pdf + Hold the button longer than 1.5 seconds and then release. +The LED blinks longer than when pressing the button once. +Z-Weather performs a factory reset and all configuration parameters are reset to their default values. Use this procedure only when the network primary controller is missing or otherwise inoperable. + + CEPT (Europe) + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1424/xml + + + + + + + + Crossing this parameter on the rising edge, Z-Weather sends a basic set to the associated groups, serves the lifeline and sends a wake up notification. + Valid values: 0-30 m/s, where 0 means no notification on too much wind. + Default: 6 + + + + + Crossing this parameter from night to day, association group 3 is informed. + Crossing this parameter from day to night, association group 4 is informed. + Valid values: 0-100 %, where 0 means off. + Default: 37 (street lightning) + + + + + + + + + + + + + diff --git a/openzwave/zwcfg.xsd b/openzwave/zwcfg.xsd new file mode 100644 index 00000000..25546d49 --- /dev/null +++ b/openzwave/zwcfg.xsd @@ -0,0 +1,249 @@ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/openzwave/zwp/PA-100.xml b/openzwave/zwp/PA-100.xml new file mode 100644 index 00000000..335f9f50 --- /dev/null +++ b/openzwave/zwp/PA-100.xml @@ -0,0 +1,49 @@ + + + http://www.openzwave.com/device-database/0315:3031:4447 + images/zwp/PA-100.png + https://products.z-wavealliance.org/products/2810/ + https://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/2810/ZL-PA-100%20UG%20v3.pdf + Z-Wave Plug-In On/Off Switch + PA-100 + Place your Z-Wave controller in "Exclusion" mode. Then tap the button to initiation Exclusion. + 1. Unplug the PA-100 from the AC outlet and also unplug the power plugs of the lighting from the module (if plugged in) +2. Press and hold the button on the PA-100 +3. Plug the PA-100 back into the AC outlet with the button pressed +After 3 seconds, release the button. If you see the button blink, that means that PA-100 has been reset successfully. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + U.S. / Canada / Mexico + Place your Z-Wave controller in "Inclusion" mode. Then tap the button once to initiation Inclusion. + ZLINK PA-100 is a Z-Wave Plus certified device with S2 security and SmartStart features. You can now add this device securely and with ease using QR code on the product with compatible gateways supporting S2 and Smart Start. PA-100 communicates with other Z-Wave certified devices and updates your home into a smart home. PA-100 can be used to turn On or Off lamps or AC operated appliances. Each Z-Wave device also serves as a node to repeat the signal in the network, thus, extending the overall Z-Wave mesh wireless network range. +Additional Features: +• Power 120 VAC, 60Hz, up to 1800 watts +• Region US: 908.4, 916 MHz +• Works with incandescent, CFL & LED lights & appliances +• Plugs into Standard AC outlet +• LED backlit On/Off button +• Control lights or appliances via schedule or remotely +• Second wall AC outlet remains free +• Works with any gateway supporting Z-Wave + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2810/xml + + + + + + DEFAULT: the LED indicator will be OFF when the connected appliance is ON, and the LED indicator will be ON when the connected appliance is OFF. +INVERTED: the LED indicator will be OFF when the connected appliance is OFF, and the LED indicator will be ON when the connected appliance is ON. +OFF: the LED indicator will be always OFF regardless of the load status. + + + + + + + + + + + + diff --git a/openzwave/zwp/WD-100.xml b/openzwave/zwp/WD-100.xml new file mode 100644 index 00000000..53c152cb --- /dev/null +++ b/openzwave/zwp/WD-100.xml @@ -0,0 +1,58 @@ + + + http://www.openzwave.com/device-database/0315:3034:4447 + images/zwp/WD-100.png + https://products.z-wavealliance.org/products/2808/ + https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2808/ZL-WD-100 UG v3.pdf + Z-Wave In-Wall Dimmer + WD-100 + Place your Z-Wave controller in "Exclusion" mode. Then tap either the top or bottom paddle once to initiation Exclusion. + 1. Turn the connected light ON with the rocker +2. Quickly tap the topside of the rocker 3 times +3. Then quickly tap the bottom side of the rocker 3 times +If you see the lights turn OFF then ON it means that the module has been rest successfully. + +Please use this procedure only when the network primary controller is missing or otherwise inoperable. + U.S. / Canada / Mexico + Place your Z-Wave controller in "Inclusion" mode. Then tap either the top or bottom paddle once to initiation Inclusion. + ZLINK’s WD-100 is a Z-Wave Plus certified device with S2 security and SmartStart features. You can now add this device securely and with ease using QR code on the product with compatible gateways supporting S2 and Smart Start. The elegant WD-100, with 7 LED dim level lights, communicates with other Z-Wave certified devices and updates your home into a smart home. WD-100 replaces a standard in-wall light switch turning it into a Z-Wave controlled network device with manual and remote control dimming and On/Off light control. ZLINK WD-100 supports, “Instant Feedback” of manual status to compatible gateways as well as Central Scene to allow setting multiple scene control throughout the home, with gateways supporting Central Scene. Each Z-Wave device serves as a node to repeat the signal in the network, thus, extending the overall Z-Wave mesh wireless network range. +Additional Features: +• Power 120 VAC, 60Hz, up to 600 watts +• Region US: 908.4, 916 MHz +• Works w/ most incandescent, dimmable CFL & LED lights +• 7 segment LED dim level indicator +• Remotely or manually turns ON or OFF, or DIM lights +• Fits standard wall plates (wall plate not included) +• Works with any certified gateway supporting Z-Wave + + Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2299/xml + Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2808/xml + + + + + + Controls the on/off orientation of the rocker switch + + + + + Number of dim levels to change for each dim step when remotely commanded + + + Interval between dimming steps when remotely commanded + + + Indicates the number of levels (1-99) to change dimming each step + + + The number of tens of milliseconds (1-255) to delay on each dimming step. + + + + + + + + + diff --git a/openzwave/zwscene.xsd b/openzwave/zwscene.xsd new file mode 100644 index 00000000..0fe91b14 --- /dev/null +++ b/openzwave/zwscene.xsd @@ -0,0 +1,28 @@ + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/pam.d/ppp b/pam.d/ppp new file mode 100644 index 00000000..b3e3a681 --- /dev/null +++ b/pam.d/ppp @@ -0,0 +1,6 @@ +#%PAM-1.0 +# Information for the PPPD process with the 'login' option. +auth required pam_nologin.so +@include common-auth +@include common-account +@include common-session diff --git a/passwd b/passwd index 92485a58..08720998 100644 --- a/passwd +++ b/passwd @@ -39,3 +39,4 @@ tftp:x:117:123:tftp daemon,,,:/srv/tftp:/usr/sbin/nologin Debian-exim:x:118:124::/var/spool/exim4:/usr/sbin/nologin iobroker:x:1001:1001::/home/iobroker:/usr/sbin/nologin ghost:x:997:993::/home/ghost:/bin/bash +dnsmasq:x:110:65534:dnsmasq,,,:/var/lib/misc:/usr/sbin/nologin diff --git a/passwd- b/passwd- index 02bd44eb..5ac93cea 100644 --- a/passwd- +++ b/passwd- @@ -13,7 +13,7 @@ proxy:x:13:13:proxy:/bin:/usr/sbin/nologin www-data:x:33:33:www-data:/var/www:/usr/sbin/nologin backup:x:34:34:backup:/var/backups:/usr/sbin/nologin list:x:38:38:Mailing List Manager:/var/list:/usr/sbin/nologin -irc:x:39:39:ircd:/var/run/ircd:/usr/sbin/nologin +irc:x:39:39:ircd:/run/ircd:/usr/sbin/nologin gnats:x:41:41:Gnats Bug-Reporting System (admin):/var/lib/gnats:/usr/sbin/nologin nobody:x:65534:65534:nobody:/nonexistent:/usr/sbin/nologin systemd-timesync:x:100:102:systemd Time Synchronization,,,:/run/systemd:/usr/sbin/nologin @@ -38,5 +38,5 @@ ntp:x:116:122::/nonexistent:/usr/sbin/nologin tftp:x:117:123:tftp daemon,,,:/srv/tftp:/usr/sbin/nologin Debian-exim:x:118:124::/var/spool/exim4:/usr/sbin/nologin iobroker:x:1001:1001::/home/iobroker:/usr/sbin/nologin -openhab:x:110:115:openhab runtime user,,,:/var/lib/openhab:/bin/false ghost:x:997:993::/home/ghost:/bin/bash +dnsmasq:x:110:65534::/var/lib/misc:/usr/sbin/nologin diff --git a/ppp/chap-secrets b/ppp/chap-secrets new file mode 100644 index 00000000..7fc2ddce --- /dev/null +++ b/ppp/chap-secrets @@ -0,0 +1,4 @@ +# Secrets for authentication using CHAP +# client server secret IP addresses + + diff --git a/ppp/ip-down b/ppp/ip-down new file mode 100755 index 00000000..814076fd --- /dev/null +++ b/ppp/ip-down @@ -0,0 +1,51 @@ +#!/bin/sh +# +# This script is run by the pppd _after_ the link is brought down. +# It uses run-parts to run scripts in /etc/ppp/ip-down.d, so to delete +# routes, unset IP addresses etc. you should create script(s) there. +# +# Be aware that other packages may include /etc/ppp/ip-down.d scripts (named +# after that package), so choose local script names with that in mind. +# +# This script is called with the following arguments: +# Arg Name Example +# $1 Interface name ppp0 +# $2 The tty ttyS1 +# $3 The link speed 38400 +# $4 Local IP number 12.34.56.78 +# $5 Peer IP number 12.34.56.99 +# $6 Optional ``ipparam'' value foo + +# The environment is cleared before executing this script +# so the path must be reset. +PATH=/usr/local/sbin:/usr/sbin:/sbin:/usr/local/bin:/usr/bin:/bin +export PATH + +# These variables are for the use of the scripts run by run-parts +PPP_IFACE="$1" +PPP_TTY="$2" +PPP_SPEED="$3" +PPP_LOCAL="$4" +PPP_REMOTE="$5" +PPP_IPPARAM="$6" +export PPP_IFACE PPP_TTY PPP_SPEED PPP_LOCAL PPP_REMOTE PPP_IPPARAM + +# as an additional convenience, $PPP_TTYNAME is set to the tty name, +# stripped of /dev/ (if present) for easier matching. +PPP_TTYNAME=$(/usr/bin/basename "$2") +export PPP_TTYNAME + +# If /var/log/ppp-ipupdown.log exists use it for logging. +if [ -e /var/log/ppp-ipupdown.log ]; then + exec >> /var/log/ppp-ipupdown.log 2>&1 + echo "$0" "$@" + echo +fi + +# This script can be used to override the .d files supplied by other packages. +if [ -x /etc/ppp/ip-down.local ]; then + exec /etc/ppp/ip-down.local "$@" +fi + +run-parts /etc/ppp/ip-down.d \ + --arg="$1" --arg="$2" --arg="$3" --arg="$4" --arg="$5" --arg="$6" diff --git a/ppp/ip-down.d/0000usepeerdns b/ppp/ip-down.d/0000usepeerdns new file mode 100755 index 00000000..bc4f158e --- /dev/null +++ b/ppp/ip-down.d/0000usepeerdns @@ -0,0 +1,28 @@ +#!/bin/sh -e + +# exit if the resolvconf package is installed +[ -x /sbin/resolvconf ] && exit 0 + +# exit if systemd-resolved is running +[ -e /run/systemd/system ] && \ + systemctl is-active --quiet systemd-resolved.service && + exit 0 + +# follow any symlink to find the real file +if [ -e /etc/resolv.conf ]; then + REALRESOLVCONF=$(readlink --canonicalize /etc/resolv.conf) +else + REALRESOLVCONF=/etc/resolv.conf +fi + +# if an old resolv.conf file exists, restore it +if [ -e $REALRESOLVCONF.pppd-backup.$PPP_IFACE ]; then + mv -f $REALRESOLVCONF.pppd-backup.$PPP_IFACE $REALRESOLVCONF + + # restart nscd because resolv.conf has changed + if [ -e /var/run/nscd.pid ]; then + /etc/init.d/nscd restart || true + fi +fi + +exit 0 diff --git a/ppp/ip-pre-up b/ppp/ip-pre-up new file mode 100755 index 00000000..c6322f80 --- /dev/null +++ b/ppp/ip-pre-up @@ -0,0 +1,51 @@ +#!/bin/sh +# +# This script is run by the pppd after the link is established but before it's brought up. +# It uses run-parts to run scripts in /etc/ppp/ip-pre-up.d, so to delete default routes, +# configure the new interface etc. you should create script(s) there. +# +# Be aware that other packages may include /etc/ppp/ip-pre-up.d scripts (named +# after that package), so choose local script names with that in mind. +# +# This script is called with the following arguments: +# Arg Name Example +# $1 Interface name ppp0 +# $2 The tty ttyS1 +# $3 The link speed 38400 +# $4 Local IP number 12.34.56.78 +# $5 Peer IP number 12.34.56.99 +# $6 Optional ``ipparam'' value foo + +# The environment is cleared before executing this script +# so the path must be reset. +PATH=/usr/local/sbin:/usr/sbin:/sbin:/usr/local/bin:/usr/bin:/bin +export PATH + +# These variables are for the use of the scripts run by run-parts +PPP_IFACE="$1" +PPP_TTY="$2" +PPP_SPEED="$3" +PPP_LOCAL="$4" +PPP_REMOTE="$5" +PPP_IPPARAM="$6" +export PPP_IFACE PPP_TTY PPP_SPEED PPP_LOCAL PPP_REMOTE PPP_IPPARAM + +# as an additional convenience, $PPP_TTYNAME is set to the tty name, +# stripped of /dev/ (if present) for easier matching. +PPP_TTYNAME=$(/usr/bin/basename "$2") +export PPP_TTYNAME + +# If /var/log/ppp-ipupdown.log exists use it for logging. +if [ -e /var/log/ppp-ipupdown.log ]; then + exec > /var/log/ppp-ipupdown.log 2>&1 + echo "$0" "$@" + echo +fi + +# This script can be used to override the .d files supplied by other packages. +if [ -x /etc/ppp/ip-pre-up.local ]; then + exec /etc/ppp/ip-pre-up.local "$@" +fi + +run-parts /etc/ppp/ip-pre-up.d \ + --arg="$1" --arg="$2" --arg="$3" --arg="$4" --arg="$5" --arg="$6" diff --git a/ppp/ip-up b/ppp/ip-up new file mode 100755 index 00000000..41ac8ad7 --- /dev/null +++ b/ppp/ip-up @@ -0,0 +1,58 @@ +#!/bin/sh +# +# This script is run by the pppd after the link is established. +# It uses run-parts to run scripts in /etc/ppp/ip-up.d, so to add routes, +# set IP address, run the mailq etc. you should create script(s) there. +# +# Be aware that other packages may include /etc/ppp/ip-up.d scripts (named +# after that package), so choose local script names with that in mind. +# +# This script is called with the following arguments: +# Arg Name Example +# $1 Interface name ppp0 +# $2 The tty ttyS1 +# $3 The link speed 38400 +# $4 Local IP number 12.34.56.78 +# $5 Peer IP number 12.34.56.99 +# $6 Optional ``ipparam'' value foo + +# The environment is cleared before executing this script +# so the path must be reset. +PATH=/usr/local/sbin:/usr/sbin:/sbin:/usr/local/bin:/usr/bin:/bin +export PATH + +# These variables are for the use of the scripts run by run-parts +PPP_IFACE="$1" +PPP_TTY="$2" +PPP_SPEED="$3" +PPP_LOCAL="$4" +PPP_REMOTE="$5" +PPP_IPPARAM="$6" +export PPP_IFACE PPP_TTY PPP_SPEED PPP_LOCAL PPP_REMOTE PPP_IPPARAM + +# as an additional convenience, $PPP_TTYNAME is set to the tty name, +# stripped of /dev/ (if present) for easier matching. +PPP_TTYNAME=$(/usr/bin/basename "$2") +export PPP_TTYNAME + +# If /var/log/ppp-ipupdown.log exists use it for logging. +if [ -e /var/log/ppp-ipupdown.log ]; then + exec >> /var/log/ppp-ipupdown.log 2>&1 + echo "$0" "$@" + echo +fi + +# This script can be used to override the .d files supplied by other packages. +if [ -x /etc/ppp/ip-up.local ]; then + exec /etc/ppp/ip-up.local "$@" +fi + +run-parts /etc/ppp/ip-up.d \ + --arg="$1" --arg="$2" --arg="$3" --arg="$4" --arg="$5" --arg="$6" + +# if pon was called with the "quick" argument, stop pppd +if [ -e /var/run/ppp-quick ]; then + rm /var/run/ppp-quick + wait + kill "$PPPD_PID" +fi diff --git a/ppp/ip-up.d/0000usepeerdns b/ppp/ip-up.d/0000usepeerdns new file mode 100755 index 00000000..ea927700 --- /dev/null +++ b/ppp/ip-up.d/0000usepeerdns @@ -0,0 +1,37 @@ +#!/bin/sh -e + +# this variable is only set if the usepeerdns pppd option is being used +[ "$USEPEERDNS" ] || exit 0 + +# exit if the resolvconf package is installed +[ -x /sbin/resolvconf ] && exit 0 + +# exit if systemd-resolved is running +[ -e /run/systemd/system ] && \ + systemctl is-active --quiet systemd-resolved.service && + exit 0 + +# create the file if it does not exist +if [ ! -e /etc/resolv.conf ]; then + : > /etc/resolv.conf +fi + +# follow any symlink to find the real file +REALRESOLVCONF=$(readlink --canonicalize /etc/resolv.conf) + +# merge the new nameservers with the other options from the old configuration +{ + cat /etc/ppp/resolv.conf + grep --invert-match '^nameserver[[:space:]]' "$REALRESOLVCONF" || true +} > "$REALRESOLVCONF.tmp" + +# backup the old configuration and install the new one +cp -a "$REALRESOLVCONF" "$REALRESOLVCONF.pppd-backup.$PPP_IFACE" +mv -f "$REALRESOLVCONF.tmp" "$REALRESOLVCONF" + +# restart nscd because resolv.conf has changed +if [ -e /var/run/nscd.pid ]; then + /etc/init.d/nscd restart || true +fi + +exit 0 diff --git a/ppp/ipv6-down b/ppp/ipv6-down new file mode 100755 index 00000000..51954c66 --- /dev/null +++ b/ppp/ipv6-down @@ -0,0 +1,30 @@ +#!/bin/sh + +# The environment is cleared before executing this script +# so the path must be reset. +PATH=/usr/local/sbin:/usr/sbin:/sbin:/usr/local/bin:/usr/bin:/bin +export PATH + +# These variables are for the use of the scripts run by run-parts +PPP_IFACE="$1" +PPP_TTY="$2" +PPP_SPEED="$3" +PPP_LOCAL="$4" +PPP_REMOTE="$5" +PPP_IPPARAM="$6" +export PPP_IFACE PPP_TTY PPP_SPEED PPP_LOCAL PPP_REMOTE PPP_IPPARAM + +# If /var/log/ppp-ipupdown.log exists use it for logging. +if [ -e /var/log/ppp-ipupdown.log ]; then + exec >> /var/log/ppp-ipupdown.log 2>&1 + echo "$0" "$@" + echo +fi + +# This script can be used to override the .d files supplied by other packages. +if [ -x /etc/ppp/ipv6-down.local ]; then + exec /etc/ppp/ipv6-down.local "$@" +fi + +run-parts /etc/ppp/ipv6-down.d \ + --arg="$1" --arg="$2" --arg="$3" --arg="$4" --arg="$5" --arg="$6" diff --git a/ppp/ipv6-up b/ppp/ipv6-up new file mode 100755 index 00000000..22d8f6af --- /dev/null +++ b/ppp/ipv6-up @@ -0,0 +1,37 @@ +#!/bin/sh + +# The environment is cleared before executing this script +# so the path must be reset. +PATH=/usr/local/sbin:/usr/sbin:/sbin:/usr/local/bin:/usr/bin:/bin +export PATH + +# These variables are for the use of the scripts run by run-parts +PPP_IFACE="$1" +PPP_TTY="$2" +PPP_SPEED="$3" +PPP_LOCAL="$4" +PPP_REMOTE="$5" +PPP_IPPARAM="$6" +export PPP_IFACE PPP_TTY PPP_SPEED PPP_LOCAL PPP_REMOTE PPP_IPPARAM + +# If /var/log/ppp-ipupdown.log exists use it for logging. +if [ -e /var/log/ppp-ipupdown.log ]; then + exec >> /var/log/ppp-ipupdown.log 2>&1 + echo "$0" "$@" + echo +fi + +# This script can be used to override the .d files supplied by other packages. +if [ -x /etc/ppp/ipv6-up.local ]; then + exec /etc/ppp/ipv6-up.local "$@" +fi + +run-parts /etc/ppp/ipv6-up.d \ + --arg="$1" --arg="$2" --arg="$3" --arg="$4" --arg="$5" --arg="$6" + +# if pon was called with the "quick" argument, stop pppd +if [ -e /var/run/ppp-quick ]; then + rm /var/run/ppp-quick + wait + kill "$PPPD_PID" +fi diff --git a/ppp/options b/ppp/options new file mode 100644 index 00000000..706647d7 --- /dev/null +++ b/ppp/options @@ -0,0 +1,348 @@ +# /etc/ppp/options +# +# Originally created by Jim Knoble +# Modified for Debian by alvar Bray +# Modified for PPP Server setup by Christoph Lameter +# +# To quickly see what options are active in this file, use this command: +# egrep -v '#|^ *$' /etc/ppp/options + +# Specify which DNS Servers the incoming Win95 or WinNT Connection should use +# Two Servers can be remotely configured +# ms-dns 192.168.1.1 +# ms-dns 192.168.1.2 + +# Specify which WINS Servers the incoming connection Win95 or WinNT should use +# ms-wins 192.168.1.50 +# ms-wins 192.168.1.51 + +# Run the executable or shell command specified after pppd has +# terminated the link. This script could, for example, issue commands +# to the modem to cause it to hang up if hardware modem control signals +# were not available. +#disconnect "chat -- \d+++\d\c OK ath0 OK" + +# async character map -- 32-bit hex; each bit is a character +# that needs to be escaped for pppd to receive it. 0x00000001 +# represents '\x01', and 0x80000000 represents '\x1f'. +asyncmap 0 + +# Require the peer to authenticate itself before allowing network +# packets to be sent or received. +# Please do not disable this setting. It is expected to be standard in +# future releases of pppd. Use the call option (see manpage) to disable +# authentication for specific peers. +auth + +# Use hardware flow control (i.e. RTS/CTS) to control the flow of data +# on the serial port. +crtscts + +# Use software flow control (i.e. XON/XOFF) to control the flow of data +# on the serial port. +#xonxoff + +# Specifies that certain characters should be escaped on transmission +# (regardless of whether the peer requests them to be escaped with its +# async control character map). The characters to be escaped are +# specified as a list of hex numbers separated by commas. Note that +# almost any character can be specified for the escape option, unlike +# the asyncmap option which only allows control characters to be +# specified. The characters which may not be escaped are those with hex +# values 0x20 - 0x3f or 0x5e. +#escape 11,13,ff + +# Don't use the modem control lines. +#local + +# Specifies that pppd should use a UUCP-style lock on the serial device +# to ensure exclusive access to the device. +lock + +# Don't show the passwords when logging the contents of PAP packets. +# This is the default. +hide-password + +# When logging the contents of PAP packets, this option causes pppd to +# show the password string in the log message. +#show-password + +# Use the modem control lines. On Ultrix, this option implies hardware +# flow control, as for the crtscts option. (This option is not fully +# implemented.) +modem + +# Set the MRU [Maximum Receive Unit] value to for negotiation. pppd +# will ask the peer to send packets of no more than bytes. The +# minimum MRU value is 128. The default MRU value is 1500. A value of +# 296 is recommended for slow links (40 bytes for TCP/IP header + 256 +# bytes of data). +#mru 542 + +# Set the interface netmask to , a 32 bit netmask in "decimal dot" +# notation (e.g. 255.255.255.0). +#netmask 255.255.255.0 + +# Disables the default behaviour when no local IP address is specified, +# which is to determine (if possible) the local IP address from the +# hostname. With this option, the peer will have to supply the local IP +# address during IPCP negotiation (unless it specified explicitly on the +# command line or in an options file). +#noipdefault + +# Enables the "passive" option in the LCP. With this option, pppd will +# attempt to initiate a connection; if no reply is received from the +# peer, pppd will then just wait passively for a valid LCP packet from +# the peer (instead of exiting, as it does without this option). +#passive + +# With this option, pppd will not transmit LCP packets to initiate a +# connection until a valid LCP packet is received from the peer (as for +# the "passive" option with old versions of pppd). +#silent + +# Don't request or allow negotiation of any options for LCP and IPCP +# (use default values). +#-all + +# Disable Address/Control compression negotiation (use default, i.e. +# address/control field disabled). +#-ac + +# Disable asyncmap negotiation (use the default asyncmap, i.e. escape +# all control characters). +#-am + +# Don't fork to become a background process (otherwise pppd will do so +# if a serial device is specified). +#-detach + +# Disable IP address negotiation (with this option, the remote IP +# address must be specified with an option on the command line or in +# an options file). +#-ip + +# Disable IPCP negotiation and IP communication. This option should +# only be required if the peer is buggy and gets confused by requests +# from pppd for IPCP negotiation. +#noip + +# Disable magic number negotiation. With this option, pppd cannot +# detect a looped-back line. +#-mn + +# Disable MRU [Maximum Receive Unit] negotiation (use default, i.e. +# 1500). +#-mru + +# Disable protocol field compression negotiation (use default, i.e. +# protocol field compression disabled). +#-pc + +# Require the peer to authenticate itself using PAP. +#+pap + +# Don't agree to authenticate using PAP. +#-pap + +# Require the peer to authenticate itself using CHAP [Cryptographic +# Handshake Authentication Protocol] authentication. +#+chap + +# Don't agree to authenticate using CHAP. +#-chap + +# Disable negotiation of Van Jacobson style IP header compression (use +# default, i.e. no compression). +#-vj + +# Increase debugging level (same as -d). If this option is given, pppd +# will log the contents of all control packets sent or received in a +# readable form. The packets are logged through syslog with facility +# daemon and level debug. This information can be directed to a file by +# setting up /etc/syslog.conf appropriately (see syslog.conf(5)). (If +# pppd is compiled with extra debugging enabled, it will log messages +# using facility local2 instead of daemon). +#debug + +# Append the domain name to the local host name for authentication +# purposes. For example, if gethostname() returns the name porsche, +# but the fully qualified domain name is porsche.Quotron.COM, you would +# use the domain option to set the domain name to Quotron.COM. +#domain + +# Enable debugging code in the kernel-level PPP driver. The argument n +# is a number which is the sum of the following values: 1 to enable +# general debug messages, 2 to request that the contents of received +# packets be printed, and 4 to request that the contents of transmitted +# packets be printed. +#kdebug n + +# Set the MTU [Maximum Transmit Unit] value to . Unless the peer +# requests a smaller value via MRU negotiation, pppd will request that +# the kernel networking code send data packets of no more than n bytes +# through the PPP network interface. +#mtu + +# Set the name of the local system for authentication purposes to . +# This is a privileged option. With this option, pppd will use lines in the +# secrets files which have as the second field when looking for a +# secret to use in authenticating the peer. In addition, unless overridden +# with the user option, will be used as the name to send to the peer +# when authenticating the local system to the peer. (Note that pppd does +# not append the domain name to .) +#name + +# Enforce the use of the hostname as the name of the local system for +# authentication purposes (overrides the name option). +#usehostname + +# Set the assumed name of the remote system for authentication purposes +# to . +#remotename + +# Add an entry to this system's ARP [Address Resolution Protocol] +# table with the IP address of the peer and the Ethernet address of this +# system. +#proxyarp + +# Use the system password database for authenticating the peer using +# PAP. Note: mgetty already provides this option. If this is specified +# then dialin from users using a script under Linux to fire up ppp wont work. +# login + +# If this option is given, pppd will send an LCP echo-request frame to the +# peer every n seconds. Normally the peer should respond to the echo-request +# by sending an echo-reply. This option can be used with the +# lcp-echo-failure option to detect that the peer is no longer connected. +lcp-echo-interval 30 + +# If this option is given, pppd will presume the peer to be dead if n +# LCP echo-requests are sent without receiving a valid LCP echo-reply. +# If this happens, pppd will terminate the connection. Use of this +# option requires a non-zero value for the lcp-echo-interval parameter. +# This option can be used to enable pppd to terminate after the physical +# connection has been broken (e.g., the modem has hung up) in +# situations where no hardware modem control lines are available. +lcp-echo-failure 4 + +# Set the LCP restart interval (retransmission timeout) to seconds +# (default 3). +#lcp-restart + +# Set the maximum number of LCP terminate-request transmissions to +# (default 3). +#lcp-max-terminate + +# Set the maximum number of LCP configure-request transmissions to +# (default 10). +#lcp-max-configure + +# Set the maximum number of LCP configure-NAKs returned before starting +# to send configure-Rejects instead to (default 10). +#lcp-max-failure + +# Set the IPCP restart interval (retransmission timeout) to +# seconds (default 3). +#ipcp-restart + +# Set the maximum number of IPCP terminate-request transmissions to +# (default 3). +#ipcp-max-terminate + +# Set the maximum number of IPCP configure-request transmissions to +# (default 10). +#ipcp-max-configure + +# Set the maximum number of IPCP configure-NAKs returned before starting +# to send configure-Rejects instead to (default 10). +#ipcp-max-failure + +# Set the PAP restart interval (retransmission timeout) to seconds +# (default 3). +#pap-restart + +# Set the maximum number of PAP authenticate-request transmissions to +# (default 10). +#pap-max-authreq + +# Set the maximum time that pppd will wait for the peer to authenticate +# itself with PAP to seconds (0 means no limit). +#pap-timeout + +# Set the CHAP restart interval (retransmission timeout for +# challenges) to seconds (default 3). +#chap-restart + +# Set the maximum number of CHAP challenge transmissions to +# (default 10). +#chap-max-challenge + +# If this option is given, pppd will rechallenge the peer every +# seconds. +#chap-interval + +# With this option, pppd will accept the peer's idea of our local IP +# address, even if the local IP address was specified in an option. +#ipcp-accept-local + +# With this option, pppd will accept the peer's idea of its (remote) IP +# address, even if the remote IP address was specified in an option. +#ipcp-accept-remote + +# Disable the IPXCP and IPX protocols. +# To let pppd pass IPX packets comment this out --- you'll probably also +# want to install ipxripd, and have the Internal IPX Network option enabled +# in your kernel. /usr/doc/HOWTO/IPX-HOWTO.gz contains more info. +noipx + +# Exit once a connection has been made and terminated. This is the default, +# unless the `persist' or `demand' option has been specified. +#nopersist + +# Do not exit after a connection is terminated; instead try to reopen +# the connection. +#persist + +# Terminate after n consecutive failed connection attempts. +# A value of 0 means no limit. The default value is 10. +#maxfail + +# Initiate the link only on demand, i.e. when data traffic is present. +# With this option, the remote IP address must be specified by the user on +# the command line or in an options file. Pppd will initially configure +# the interface and enable it for IP traffic without connecting to the peer. +# When traffic is available, pppd will connect to the peer and perform +# negotiation, authentication, etc. When this is completed, pppd will +# commence passing data packets (i.e., IP packets) across the link. +#demand + +# Specifies that pppd should disconnect if the link is idle for seconds. +# The link is idle when no data packets (i.e. IP packets) are being sent or +# received. Note: it is not advisable to use this option with the persist +# option without the demand option. If the active-filter option is given, +# data packets which are rejected by the specified activity filter also +# count as the link being idle. +#idle + +# Specifies how many seconds to wait before re-initiating the link after +# it terminates. This option only has any effect if the persist or demand +# option is used. The holdoff period is not applied if the link was +# terminated because it was idle. +#holdoff + +# Wait for up n milliseconds after the connect script finishes for a valid +# PPP packet from the peer. At the end of this time, or when a valid PPP +# packet is received from the peer, pppd will commence negotiation by +# sending its first LCP packet. The default value is 1000 (1 second). +# This wait period only applies if the connect or pty option is used. +#connect-delay + +# Packet filtering: for more information, see pppd(8) +# Any packets matching the filter expression will be interpreted as link +# activity, and will cause a "demand" connection to be activated, and reset +# the idle connection timer. (idle option) +# The filter expression is akin to that of tcpdump(1) +#active-filter + +# ------ diff --git a/ppp/pap-secrets b/ppp/pap-secrets new file mode 100644 index 00000000..ab5d8aea --- /dev/null +++ b/ppp/pap-secrets @@ -0,0 +1,43 @@ +# +# /etc/ppp/pap-secrets +# +# This is a pap-secrets file to be used with the AUTO_PPP function of +# mgetty. mgetty-0.99 is preconfigured to startup pppd with the login option +# which will cause pppd to consult /etc/passwd (and /etc/shadow in turn) +# after a user has passed this file. Don't be disturbed therefore by the fact +# that this file defines logins with any password for users. /etc/passwd +# (again, /etc/shadow, too) will catch passwd mismatches. +# +# This file should block ALL users that should not be able to do AUTO_PPP. +# AUTO_PPP bypasses the usual login program so it's necessary to list all +# system userids with regular passwords here. +# +# ATTENTION: The definitions here can allow users to login without a +# password if you don't use the login option of pppd! The mgetty Debian +# package already provides this option; make sure you don't change that. + +# INBOUND connections + +# Every regular user can use PPP and has to use passwords from /etc/passwd +* hostname "" * + +# UserIDs that cannot use PPP at all. Check your /etc/passwd and add any +# other accounts that should not be able to use pppd! +guest hostname "*" - +master hostname "*" - +root hostname "*" - +support hostname "*" - +stats hostname "*" - + +# OUTBOUND connections + +# Here you should add your userid password to connect to your providers via +# PAP. The * means that the password is to be used for ANY host you connect +# to. Thus you do not have to worry about the foreign machine name. Just +# replace password with your password. +# If you have different providers with different passwords then you better +# remove the following line. + +# * password + + diff --git a/ppp/peers/provider b/ppp/peers/provider new file mode 100644 index 00000000..e74d71a8 --- /dev/null +++ b/ppp/peers/provider @@ -0,0 +1,35 @@ +# example configuration for a dialup connection authenticated with PAP or CHAP +# +# This is the default configuration used by pon(1) and poff(1). +# See the manual page pppd(8) for information on all the options. + +# MUST CHANGE: replace myusername@realm with the PPP login name given to +# your by your provider. +# There should be a matching entry with the password in /etc/ppp/pap-secrets +# and/or /etc/ppp/chap-secrets. +user "myusername@realm" + +# MUST CHANGE: replace ******** with the phone number of your provider. +# The /etc/chatscripts/pap chat script may be modified to change the +# modem initialization string. +connect "/usr/sbin/chat -v -f /etc/chatscripts/pap -T ********" + +# Serial device to which the modem is connected. +/dev/modem + +# Speed of the serial line. +115200 + +# Assumes that your IP address is allocated dynamically by the ISP. +noipdefault +# Try to get the name server addresses from the ISP. +usepeerdns +# Use this connection as the default route. +defaultroute + +# Makes pppd "dial again" when the connection is lost. +persist + +# Do not ask the remote to authenticate. +noauth + diff --git a/systemd/system/dbus-org.freedesktop.ModemManager1.service b/systemd/system/dbus-org.freedesktop.ModemManager1.service new file mode 120000 index 00000000..6b5718bb --- /dev/null +++ b/systemd/system/dbus-org.freedesktop.ModemManager1.service @@ -0,0 +1 @@ +/lib/systemd/system/ModemManager.service \ No newline at end of file diff --git a/systemd/system/dbus-org.freedesktop.nm-dispatcher.service b/systemd/system/dbus-org.freedesktop.nm-dispatcher.service new file mode 120000 index 00000000..42c0678e --- /dev/null +++ b/systemd/system/dbus-org.freedesktop.nm-dispatcher.service @@ -0,0 +1 @@ +/lib/systemd/system/NetworkManager-dispatcher.service \ No newline at end of file diff --git a/systemd/system/multi-user.target.wants/ModemManager.service b/systemd/system/multi-user.target.wants/ModemManager.service new file mode 120000 index 00000000..6b5718bb --- /dev/null +++ b/systemd/system/multi-user.target.wants/ModemManager.service @@ -0,0 +1 @@ +/lib/systemd/system/ModemManager.service \ No newline at end of file diff --git a/systemd/system/multi-user.target.wants/NetworkManager.service b/systemd/system/multi-user.target.wants/NetworkManager.service new file mode 120000 index 00000000..7a9fab3f --- /dev/null +++ b/systemd/system/multi-user.target.wants/NetworkManager.service @@ -0,0 +1 @@ +/lib/systemd/system/NetworkManager.service \ No newline at end of file diff --git a/systemd/system/multi-user.target.wants/nymead.service b/systemd/system/multi-user.target.wants/nymead.service new file mode 120000 index 00000000..1ee5e36a --- /dev/null +++ b/systemd/system/multi-user.target.wants/nymead.service @@ -0,0 +1 @@ +/lib/systemd/system/nymead.service \ No newline at end of file diff --git a/systemd/system/network-online.target.wants/NetworkManager-wait-online.service b/systemd/system/network-online.target.wants/NetworkManager-wait-online.service new file mode 120000 index 00000000..9d824399 --- /dev/null +++ b/systemd/system/network-online.target.wants/NetworkManager-wait-online.service @@ -0,0 +1 @@ +/lib/systemd/system/NetworkManager-wait-online.service \ No newline at end of file diff --git a/systemd/user/sockets.target.wants/pk-debconf-helper.socket b/systemd/user/sockets.target.wants/pk-debconf-helper.socket new file mode 120000 index 00000000..e82d3c3a --- /dev/null +++ b/systemd/user/sockets.target.wants/pk-debconf-helper.socket @@ -0,0 +1 @@ +/usr/lib/systemd/user/pk-debconf-helper.socket \ No newline at end of file diff --git a/xdg/autostart/at-spi-dbus-bus.desktop b/xdg/autostart/at-spi-dbus-bus.desktop new file mode 100644 index 00000000..ce97c7b6 --- /dev/null +++ b/xdg/autostart/at-spi-dbus-bus.desktop @@ -0,0 +1,7 @@ +[Desktop Entry] +Type=Application +Name=AT-SPI D-Bus Bus +Exec=/usr/libexec/at-spi-bus-launcher --launch-immediately +NoDisplay=true +X-GNOME-AutoRestart=true +X-GNOME-Autostart-Phase=Initialization